Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (33)

Search Parameters:
Keywords = interior building pressure

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
27 pages, 1659 KB  
Article
Parametric Multi-Criteria Sustainability Assessment of Building Renovation Elements: A BIM-Based Three-Pillar Framework
by Maria Grazianova, Andrea Hrubovcakova, Ivana Halaszova and Peter Mesaros
Buildings 2026, 16(13), 2640; https://doi.org/10.3390/buildings16132640 - 2 Jul 2026
Viewed by 352
Abstract
The building renovation sector is under growing pressure to balance environmental responsibility, economic efficiency, and occupant well-being simultaneously. Existing evaluation approaches are predominantly finance-driven, marginalising ecological and social dimensions. This study develops and validates a parametric multi-criteria assessment framework for building renovation elements, [...] Read more.
The building renovation sector is under growing pressure to balance environmental responsibility, economic efficiency, and occupant well-being simultaneously. Existing evaluation approaches are predominantly finance-driven, marginalising ecological and social dimensions. This study develops and validates a parametric multi-criteria assessment framework for building renovation elements, structured around the three pillars of sustainability: environmental, economic, and social. A dataset of 33 renovation elements—encompassing green façade systems, extensive and intensive green roofs, interior wall, floor, and ceiling solutions, and exterior envelope and site components—was compiled and digitized as BIM objects in ArchiCAD 26, enriched with non-graphic parameters including cost, lifespan, recyclability, eco-index, maintenance effort, and qualitative social descriptors. Parameters were aggregated using type-specific logic: additive summation for economic indicators, minimum-value selection for lifespan, arithmetic mean for environmental indicators, and descriptive consolidation for social attributes. Five renovation scenarios (A–E), each composed of nine elements, were evaluated to demonstrate how the sustainability profile changes with selection priorities. Scenarios A, B, and C confirmed single-dimension dominance (environmental, economic, and social, respectively), Scenario D achieved a balanced three-pillar profile, and Scenario E revealed a latent economic bias in an apparently random element selection. The framework is scalable and extensible, and its data structure may provide a basis for future exploration of integration with BIM environments. Full article
Show Figures

Figure 1

26 pages, 7556 KB  
Article
Reduction Characteristics of Stack-Effect Problems According to Applying Local Countermeasures by Pressure Distribution Measurement in Buildings
by Taeyon Hwang, Min-ku Hwang and Joowook Kim
Buildings 2025, 15(24), 4453; https://doi.org/10.3390/buildings15244453 - 10 Dec 2025
Cited by 1 | Viewed by 1304
Abstract
Stack effects in high-rise buildings cause noise, drafts, and elevator door malfunctions during cold weather yet remain difficult to control. Because vertical shafts couple pressures between floors, local fixes at a single lobby can unintentionally disturb the pressure field elsewhere. To analyze these [...] Read more.
Stack effects in high-rise buildings cause noise, drafts, and elevator door malfunctions during cold weather yet remain difficult to control. Because vertical shafts couple pressures between floors, local fixes at a single lobby can unintentionally disturb the pressure field elsewhere. To analyze these interactions, we developed a measurement-calibrated CONTAM multizone model of a 43-story office building and evaluated representative local countermeasures. Under base winter conditions, the pressure difference across the problematic first-floor high-rise elevator doors is 56 Pa, driving approximately 1300 CMH of airflow through the door line. First-floor depressurization reduces this to 34 Pa (about 30% lower airflow) but simultaneously increases the pressure at the main entrance doors from 19 to 39 Pa. Additional first-floor partitions slightly reduce pressures on upper high-rise floors, whereas opening exterior windows in the high-rise zone increases shaft airflow by 7.7% and further amplifies elevator door pressures. We show that neutral pressure level (NPL) shifts into vertical shafts are a key mechanism limiting the effectiveness of purely local interventions. These results demonstrate that effective countermeasures must be designed at the whole-building scale, jointly controlling pressure redistribution and neutral-pressure-level movement while directing unavoidable pressure transfer toward the exterior envelope and away from sensitive interior spaces. Full article
(This article belongs to the Special Issue Built Environment and Building Energy for Decarbonization)
Show Figures

Figure 1

62 pages, 8154 KB  
Review
Assessment of Phase Change Materials Incorporation into Construction Commodities for Sustainable and Energy-Efficient Building Applications
by Ihsan Ur Rahman, Oronzio Manca, Bernardo Buonomo, Meriem Bounib, Shafi Ur Rehman, Hala Salhab, Antonio Caggiano and Sergio Nardini
Buildings 2025, 15(17), 3109; https://doi.org/10.3390/buildings15173109 - 29 Aug 2025
Cited by 11 | Viewed by 2403
Abstract
The significant energy consumption and contribution to greenhouse gas emissions by the construction sector need careful attention to explore innovative sustainable solutions for improving the energy efficiency and thermal comfort of building envelopes. The integration of phase-change materials (PCMs) into building commodities is [...] Read more.
The significant energy consumption and contribution to greenhouse gas emissions by the construction sector need careful attention to explore innovative sustainable solutions for improving the energy efficiency and thermal comfort of building envelopes. The integration of phase-change materials (PCMs) into building commodities is a favorable technology for minimizing energy consumption and enhancing thermal performance. This review paper covers the impact of PCM incorporation into construction materials, such as walls, roofs, and glazing units. Additionally, it examines different embedding techniques like direct incorporation, immersion, macro and micro-encapsulation, and form and shape-stable PCM. Factors affecting the thermal performance of PCM-integrated buildings, including melting temperature, thickness, position, volumetric change, vapor pressure, density, optical properties, latent heat, thermal conductivity, chemical stability, and climate conditions, are elaborated. Furthermore, the latest experimental and numerical simulations, as well as modeling techniques, evident from case studies, are investigated. Ultimately, the advantages of PCM integration, including energy savings, peak load reduction, improvement in interior comfort, and reduced heating, ventilation, and air-conditioning dependence, are explained alongside the limitations. Finally, the recent progress and future potential of PCM-integrated construction materials are discussed, focusing on innovations in this field, addressing the status of policies in line with the United Nations Sustainable Development Goals, and outlining research potential for the future. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Graphical abstract

11 pages, 317 KB  
Article
Phenomenological Charged Extensions of the Quantum Oppenheimer–Snyder Collapse Model
by S. Habib Mazharimousavi
Universe 2025, 11(8), 257; https://doi.org/10.3390/universe11080257 - 4 Aug 2025
Cited by 1 | Viewed by 1214
Abstract
This work presents a semi-classical, quantum-corrected model of gravitational collapse for a charged, spherically symmetric dust cloud, extending the classical Oppenheimer–Snyder (OS) framework through loop quantum gravity effects. Our goal is to study phenomenological quantum modifications to geometry, without necessarily embedding them within [...] Read more.
This work presents a semi-classical, quantum-corrected model of gravitational collapse for a charged, spherically symmetric dust cloud, extending the classical Oppenheimer–Snyder (OS) framework through loop quantum gravity effects. Our goal is to study phenomenological quantum modifications to geometry, without necessarily embedding them within full loop quantum gravity (LQG). Building upon the quantum Oppenheimer–Snyder (qOS) model, which replaces the classical singularity with a nonsingular bounce via a modified Friedmann equation, we introduce electric and magnetic charges concentrated on a massive thin shell at the boundary of the dust ball. The resulting exterior spacetime generalizes the Schwarzschild solution to a charged, regular black hole geometry akin to a quantum-corrected Reissner–Nordström metric. The Israel junction conditions are applied to match the interior APS (Ashtekar–Pawlowski–Singh) cosmological solution to the charged exterior, yielding constraints on the shell’s mass, pressure, and energy. Stability conditions are derived, including a minimum radius preventing full collapse and ensuring positivity of energy density. This study also examines the geodesic structure around the black hole, focusing on null circular orbits and effective potentials, with implications for the observational signatures of such quantum-corrected compact objects. Full article
Show Figures

Figure 1

26 pages, 2245 KB  
Review
Life Cycle Assessment with Carbon Footprint Analysis in Glulam Buildings: A Review
by Ruijing Liu, Lihong Yao, Yingchun Gong and Zhen Wang
Buildings 2025, 15(12), 2127; https://doi.org/10.3390/buildings15122127 - 19 Jun 2025
Cited by 10 | Viewed by 6713
Abstract
This study provides a bibliometric analysis of life cycle assessments (LCAs) to explore the sustainability potential of mass timber buildings, focusing on glulam. The analysis highlights regional differences in carbon footprint performance within the ISO 14040 and EN 15978 frameworks. LCA results from [...] Read more.
This study provides a bibliometric analysis of life cycle assessments (LCAs) to explore the sustainability potential of mass timber buildings, focusing on glulam. The analysis highlights regional differences in carbon footprint performance within the ISO 14040 and EN 15978 frameworks. LCA results from representative countries across six continents show that wood buildings, compared to traditional materials, have a reduced carbon footprint. The geographical distribution of forest resources significantly influences the carbon footprint of glulam production. Europe and North America demonstrate optimal performance metrics (e.g., carbon sequestration), attributable to advanced technology and investment in long-term sustainable forest management. Our review research shows the lowest glulam carbon footprints (28–70% lower than traditional materials) due to clean energy and sustainable practices. In contrast, Asia and Africa exhibit systemic deficits, driven by resource scarcity, climatic stressors, and land-use pressures. South America and Oceania display transitional dynamics, with heterogeneous outcomes influenced by localized deforestation trends and conservation efficacy. Glulam buildings outperformed concrete and steel across 11–18 environmental categories, with carbon storage offsetting 30–47% of emissions and energy mixes cutting operational impacts by up to 67%. Circular strategies like recycling and prefabrication reduced end-of-life emissions by 12–29% and cut construction time and costs. Social benefits included job creation (e.g., 1 million in the EU) and improved well-being in wooden interiors. To further reduce carbon footprint disparities, this study emphasizes sustainable forest management, longer building lifespans, optimized energy mixes, shorter transport distances, advanced production technologies, and improved recycling systems. Additionally, the circular economy and social benefits of glulam buildings, such as reduced construction costs, value recovery, and job creation, are highlighted. In the future, prioritizing equitable partnerships and enhancing international exchanges of technical expertise will facilitate the adoption of sustainable practices in glulam buildings and advance decarbonization goals in the global building sector. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

14 pages, 4243 KB  
Article
Shear Band-Induced Internal Surface Structures in a Vitreloy Bulk Metallic Glass Deformed by High-Pressure Torsion
by Zsolt Kovács, Talaye Arjmandabasi, Gábor Erdei, Erhard Schafler and Ádám Révész
Materials 2025, 18(5), 1096; https://doi.org/10.3390/ma18051096 - 28 Feb 2025
Cited by 1 | Viewed by 1164
Abstract
In the present investigation, high stability Vitreloy Zr44Ti11Cu10Ni10Be25 bulk metallic glass has been subjected to severe shear deformation by high-pressure torsion for 0.1 revolutions under an applied pressure of 4 and 8 GPa. The [...] Read more.
In the present investigation, high stability Vitreloy Zr44Ti11Cu10Ni10Be25 bulk metallic glass has been subjected to severe shear deformation by high-pressure torsion for 0.1 revolutions under an applied pressure of 4 and 8 GPa. The fully glassy nature of the as-cast glass has been confirmed by X-ray powder diffraction and differential scanning calorimetry. Deformation-induced surface features on an internal plane of the deformed disk-shaped specimens were studied in detail at the macroscopic level by optical reconstruction method and at microscopic scales by white-light optical profilometry. Shear and compressive strain components were measured based on surface changes and it was determined that compressive strain gradient with 0.2–0.4 strain change builds up toward the disk edge, while only part of the nominal shear deformation occurs in the disk interior. The effect of strain localization in the Vitreloy bulk metallic glasses has been quantified by a surface distortion model based on simple shear. The model was then validated experimentally by the reconstructed z-profiles. Full article
Show Figures

Figure 1

31 pages, 9973 KB  
Article
Measuring Airtightness of High-Rise Buildings (Lessons Learned)
by Stefanie Rolfsmeier, Emanuel Mairinger, Johannes Neubig and Thomas Gayer
Buildings 2025, 15(5), 724; https://doi.org/10.3390/buildings15050724 - 24 Feb 2025
Cited by 5 | Viewed by 4178
Abstract
Measuring the airtightness of high-rise buildings presents significant challenges due to the effects of wind and thermal lift (stack effect). Small indoor/outdoor temperature differences, combined with the building’s height, can create substantial natural pressure differences on the building envelope, while winds induce pressure [...] Read more.
Measuring the airtightness of high-rise buildings presents significant challenges due to the effects of wind and thermal lift (stack effect). Small indoor/outdoor temperature differences, combined with the building’s height, can create substantial natural pressure differences on the building envelope, while winds induce pressure fluctuations. The international standard ISO 9972 provides insufficient guidelines for dealing with these high and fluctuating natural pressure differences. In addition, it is crucial to achieve a uniform internal pressure distribution during the test. This paper discusses the airtightness testing of high-rise buildings up to 125 m tall using portable blower door devices, following the “airtightness measurement of high-rise buildings” Passive House guideline. Differential pressure sensors were placed on the ground and top floors to record the effects of wind and thermal lift, and additional sensors helped to achieve a uniform pressure distribution within the building. The readings from the ground and top floors ensured full depressurization and pressurization during testing. The setup of the measuring fans, mainly on the ground floor, was supplemented with additional fans on higher floors to maintain pressure uniformity within a 10% tolerance. To be able to conduct a multi-point regression test, it is recommended to limit the product of the indoor/outdoor temperature difference and building height to ≤1250 mK and to achieve a coefficient of determination of 0.98 or higher, a wind speed ≤ 3 Beaufort. The study concludes that an airtight building envelope and larger internal flow paths, such as stairwells and elevator shafts, simplify the measurement. Full article
(This article belongs to the Special Issue Research on the Airtightness of Buildings)
Show Figures

Figure 1

14 pages, 2647 KB  
Article
Influence of Control Strategy on Heat Recovery Efficiency in a Single-Duct Periodic Ventilation Device
by Piotr Koper
Energies 2024, 17(22), 5801; https://doi.org/10.3390/en17225801 - 20 Nov 2024
Cited by 3 | Viewed by 1440
Abstract
The subject of the research was a single-duct, decentralised periodic ventilation unit, using accumulative heat exchanger for heat recovery (also called single-core fixed-bed regenerator). It can achieve high efficiency of heat recovery but is vulnerable to pressure differences between the interior of the [...] Read more.
The subject of the research was a single-duct, decentralised periodic ventilation unit, using accumulative heat exchanger for heat recovery (also called single-core fixed-bed regenerator). It can achieve high efficiency of heat recovery but is vulnerable to pressure differences between the interior of the building and the outside. To counter this, two control strategies were proposed: adjustment of the fan speed based on an air flow sensor and adjustment of the working cycle length based on temperature sensors. The strategies were tested experimentally in actual working conditions. Due to the use of cheap and simple sensors, it was possible to retain the low price of the device. Both control strategies proved to be successful in equalising the amount of supplied and removed air in a single cycle. Moreover, the heat recovery efficiency increased by more than 10% compared to the default working mode. Full article
(This article belongs to the Special Issue Thermal Comfort, Environment Quality and Energy Consumption)
Show Figures

Figure 1

81 pages, 52483 KB  
Article
Evaluating Apartment Satisfaction in Erbil City: The Impact of Interior Space Quality Indicators before, during, and after the COVID-19 Pandemic
by Nazik Jamal Abdulhamid and Hasan Abdulrazzaq Hasan Al-Sanjary
Buildings 2024, 14(9), 2619; https://doi.org/10.3390/buildings14092619 - 24 Aug 2024
Cited by 1 | Viewed by 2000
Abstract
Human existence and development have always relied on suitable shelter. The dual-directional relationship of human residence has always been a material dealt with to enhance residential living conditions. The emergence of the COVID-19 pandemic introduced abrupt and dramatic changes to human life protocols [...] Read more.
Human existence and development have always relied on suitable shelter. The dual-directional relationship of human residence has always been a material dealt with to enhance residential living conditions. The emergence of the COVID-19 pandemic introduced abrupt and dramatic changes to human life protocols that exerted clear pressure on different sectors within the built environment. Housing experienced a great impact due to the need for social distancing and quarantine obligations to support human life. In this study, in order to measure human adaptation and residence alterations following new residential requirements, the quality of interior space investigations to promote a better built environment for occupants was facilitated using the theory of residential dissatisfaction, already adopted in the current study. Residents’ responses were extracted regarding their dissatisfaction by applying the Likert scale for measurement and evaluation. This study focused on homogenous housing estates in Erbil City. Apartments were precisely selected with different plans and building layouts for widespread use in the city. They were occupied during the three stages of the study to extend beyond investigating the direct impact of the pandemic on the permanence of alterations and adaptation even after the pandemic. The reasons for changed dissatisfaction levels were investigated to improve the reliability of formulating final conclusions and recommendations. The findings showed increased dissatisfaction during the pandemic in most spaces; apartment layout and space design significantly affected responses and demands. The levels of dissatisfaction after the pandemic changed from stable to a slight decline in dissatisfaction. The effect of limited external spaces in apartments limited the possibility of managing pressure. This case might be less demanding in single-family housing due to the availability of private gardens. The results indicate that five distinct spaces were affected by the pandemic: the living room, family dining area, children’s bedroom, laundry room, and storage area. The dissatisfaction with these spaces increased during the pandemic and either remained unchanged or continued to rise afterward. Full article
(This article belongs to the Section Architectural Design, Urban Science, and Real Estate)
Show Figures

Figure 1

14 pages, 2693 KB  
Article
Thermally Active Medium-Density Fiberboard (MDF) with the Addition of Phase Change Materials for Furniture and Interior Design
by Julia Dasiewicz, Anita Wronka, Aleksandra Jeżo and Grzegorz Kowaluk
Materials 2024, 17(16), 4001; https://doi.org/10.3390/ma17164001 - 12 Aug 2024
Cited by 7 | Viewed by 3576
Abstract
No matter where we reside, the issue of greenhouse gas emissions impacts us all. Their influence has a disastrous effect on the earth’s climate, producing global warming and many other irreversible environmental impacts, even though it is occasionally invisible to the independent eye. [...] Read more.
No matter where we reside, the issue of greenhouse gas emissions impacts us all. Their influence has a disastrous effect on the earth’s climate, producing global warming and many other irreversible environmental impacts, even though it is occasionally invisible to the independent eye. Phase change materials (PCMs) can store and release heat when it is abundant during the day (e.g., from solar radiation), for use at night, or on chilly days when buildings need to be heated. As a consequence, buildings use less energy to heat and cool, which lowers greenhouse gas emissions. Consequently, research on thermally active medium-density fiberboard (MDF) with PCMs is presented in this work. MDF is useful for interior design and furniture manufacturing. The boards were created using pine (Pinus sylvestris L.) and spruce (Picea abies L.) fibers, urea–formaldehyde resin, and PCM powder, with a phase transition temperature of 22 °C, a density of 785 kg m−3, a latent heat capacity of 160 kJ kg−1, a volumetric heat capacity of 126 MJ m−3, a specific heat capacity of 2.2 kJ kgK−1, a thermal conductivity of 0.18 W mK−1, and a maximum operating temperature of 200 °C. Before resination, the wood fibers were divided into two outer layers (16%) and an interior layer (68% by weight). Throughout the resination process, the PCM particles were solely integrated into the inner layer fibers. The mats were created by hand. A hydraulic press (AKE, Mariannelund, Sweden) was used to press the boards, and its operating parameters were 180 °C, 20 s/mm of nominal thickness, and 2.5 MPa for the maximum unit pressing pressure. Five variants of MDF with a PCM additive were developed: 0%, 5%, 10%, 30%, and 50%. According to the study, scores at the MOR, MOE, IB, and screw withdrawal resistance (SWR) tests decreased when PCM content was added, for example, MOE from 3176 to 1057 N mm−2, MOR from 41.2 to 11.5 N mm−2, and IB from 0.78 to 0.27 N mm−2. However, the results of the thickness swelling and water absorption tests indicate that the PCM particles do not exhibit a substantial capacity to absorb water, retaining the dimensional stability of the MDF boards. The thickness swelling positively decreased with the PCM content increase from 15.1 to 7.38% after 24 h of soaking. The panel’s thermal characteristics improved with the increasing PCM concentration, according to the data. The density profiles of all the variations under consideration had a somewhat U-shaped appearance; however, the version with a 50% PCM content had a flatter form and no obvious layer compaction on the panel surface. Therefore, certain mechanical and physical characteristics of the manufactured panels can be enhanced by a well-chosen PCM addition. Full article
(This article belongs to the Special Issue Thermal Stability and Fire Performance of Polymeric Materials)
Show Figures

Figure 1

21 pages, 36445 KB  
Article
Integrating Smart City Principles in the Numerical Simulation Analysis on Passive Energy Saving of Small and Medium Gymnasiums
by Feng Qian, Hongliang Sun and Li Yang
Smart Cities 2024, 7(4), 1971-1991; https://doi.org/10.3390/smartcities7040078 - 25 Jul 2024
Cited by 12 | Viewed by 3004
Abstract
With the increasing energy consumption in buildings, the proportion of energy consumption in public buildings continues to grow. As an essential component of public buildings, sports buildings are receiving more attention regarding energy-saving technologies. This paper aims to study the passive energy-saving design [...] Read more.
With the increasing energy consumption in buildings, the proportion of energy consumption in public buildings continues to grow. As an essential component of public buildings, sports buildings are receiving more attention regarding energy-saving technologies. This paper aims to study the passive energy-saving design methods of small-and medium-sized sports halls in hot summer and cold winter regions, exploring how to reduce building energy consumption by improving the spatial design and thermal performance of the enclosure structures of sports halls. Taking the Wuhu County Sports Center as an example, this study uses computer simulation software to analyze the building’s wind environment and the thermal performance of its external walls and roof. The results show that the large volume of the sports hall significantly impacts the distribution of wind speed and pressure around it, and this impact decreases with height. The thermal simulation of the enclosure structures demonstrates that adding insulation layers to the interior and exterior of the walls and roof of the sports hall is an effective way to reduce energy consumption in both winter and summer. Additionally, wind environment simulations of different roof shapes reveal that flat roofs have the most significant blocking effect on wind and are prone to inducing strong vortices on the leeward side; concave arch roofs have the least blocking effect on airflow, and arch and wave-shaped roofs maintain lower vortex intensity on the leeward side. Hopefully, this study can provide significant references for the energy-saving design of future small- and medium-sized sports buildings. Full article
Show Figures

Figure 1

21 pages, 5073 KB  
Article
Adding Green to Architectures: Empirical Research Based on Indoor Vertical Greening of the Emotional Promotion on Adolescents
by Chengcheng Wang, Qizhi Hu, Zijun Zhou, Di Li and Linjia Wu
Buildings 2024, 14(7), 2251; https://doi.org/10.3390/buildings14072251 - 22 Jul 2024
Cited by 6 | Viewed by 2673
Abstract
Good architectural space design can bring positive emotional stimulation and relaxation to users, but few studies have investigated the quantitative indicators in architectural space design and their impact on user emotions. This study takes the right-angle sandwich interface system in architecture as an [...] Read more.
Good architectural space design can bring positive emotional stimulation and relaxation to users, but few studies have investigated the quantitative indicators in architectural space design and their impact on user emotions. This study takes the right-angle sandwich interface system in architecture as an example to guide the next vertical greening simulation experiment by comparing the spatial quantitative differences in connection value, integration degree, and population agglomeration. Eighty adolescent volunteers were recruited into a control (artificial decorative wall) and experimental (green wall) group based on wall type. We compared their physiological and psychological indicators, including blood pressure and blood oxygen, and psychological indicators, including POMS and SIAI-S scales. Then, we made predictive factor judgements on vertical green elements. The quantification of the interior space of the building showed consistency in parameter changes, with the central area being the area of connectivity, integration, and crowd aggregation values. After the experiment, the experimental group showed a significant decrease in diastolic blood pressure, systolic blood pressure, and heart rate (p = 0.00) and a significant decrease in tension, anger, fatigue, depression, and panic (p = 0.00). The quantitative relationship between vertical greening elements and emotional promotion using stepwise linear exploration shows that the “vine” element is a significant predictive factor for diastolic blood pressure, T-A emotion, and SIAI-S values. The results enrich the indoor optimization and creation expansion paths of interface systems for various spatial experiences and further provide guidance for urban indoor green construction plans and green landscape facility planning via the emotional influence of indoor vertical space greening on young people. Full article
(This article belongs to the Special Issue Indoor Environmental Quality and Human Wellbeing)
Show Figures

Figure 1

16 pages, 7125 KB  
Article
Evaluation of the Properties and Reaction-to-Fire Performance of Binderless Particleboards Made from Canary Island Palm Trunks
by Berta Elena Ferrandez-Garcia, Teresa Garcia-Ortuño, Manuel Ferrandez-Villena and Maria Teresa Ferrandez-Garcia
Fire 2024, 7(6), 193; https://doi.org/10.3390/fire7060193 - 8 Jun 2024
Cited by 3 | Viewed by 2919
Abstract
Repurposing agricultural and forestry by-products not only is beneficial for the environment but also follows the principles of the circular economy. In southeastern Spain, the Canary Island palm tree (Phoenix canariensis W.) is widely used in urban landscapes. Plantations affected by the [...] Read more.
Repurposing agricultural and forestry by-products not only is beneficial for the environment but also follows the principles of the circular economy. In southeastern Spain, the Canary Island palm tree (Phoenix canariensis W.) is widely used in urban landscapes. Plantations affected by the red weevil, a pest, generate an abundance of plant waste that must be crushed and transferred to authorized landfills. The aim of this study was to manufacture boards using particles from trunks of the Canary Island palm tree without adding any binders in order to obtain an ecological and fire-resistant product. In order to manufacture the boards, three particle sizes (<0.25, 0.25–1, and 1–2 mm), a temperature of 110 °C, a pressure of 2.6 MPa, and a pressing time of 7 min were used. The boards were pressed in a hot plate press for 7 min up to four times (7 min, 7 + 7 min, 7 + 7 + 7 min, and 7 + 7 + 7 + 7 min). The resulting boards showed good thermal performance, and the board´s reaction-to-fire performance was classified as Bd0 (an Fs value of 70.3 mm). This study also showed that boards with a particle size smaller than 0.25 mm that underwent four pressing cycles of 7 min each in the press can be categorized as grade P2 according to the European Standards (MOR of 20 N/mm2, MOE of 2589.8 N/mm2, and IB of 0.74 N/mm2). Therefore, these manufactured particleboards could be used as a flame-retardant material for the interior enclosures of buildings (vertical and horizontal) without the need for coatings. Full article
(This article belongs to the Special Issue Fire Prevention and Flame Retardant Materials)
Show Figures

Figure 1

24 pages, 10826 KB  
Article
Optimization of Thermal Bridges Effect of Composite Lightweight Panels with Integrated Steel Load-Bearing Structure
by Domagoj Tkalčić, Bojan Milovanović, Mergim Gaši, Marija Jelčić Rukavina and Ivana Banjad Pečur
Energies 2023, 16(18), 6474; https://doi.org/10.3390/en16186474 - 7 Sep 2023
Cited by 11 | Viewed by 3255
Abstract
In order to maintain the quality of construction for nearly zero energy buildings and to reduce the pressure on construction workers with the addition of the need for faster and simpler structures, the use of cavity-insulated LSF (lightweight steel frame) panels is increasing. [...] Read more.
In order to maintain the quality of construction for nearly zero energy buildings and to reduce the pressure on construction workers with the addition of the need for faster and simpler structures, the use of cavity-insulated LSF (lightweight steel frame) panels is increasing. Requirements for performance quality, quality of life, and low energy consumption have led to the need for closer examination of heat transfer through building elements. Due to the impact on increased heat losses, thermal bridges can cause structural damage due to the increased risk of water vapor condensation on the interior surface. In this paper, numerical heat transfer analysis with the optimization of thermal bridges for LSF cavity insulated walls was made in order to reduce the overall transmission heat losses. The effects of different cavity insulation materials (mineral wool and polyurethane foam) on overall heat transferred through the building elements were analyzed. Additionally, in order to reduce the effect of thermal bridges caused by the steel frame structure, the PVC spacers between the steel and sheathing panels are introduced into calculation models. Lastly, additional layers of insulation were added on the internal and external sides of the LFS panels in order to minimize the effect of thermal bridges and maximize air tightness. Combinations of all three setups were made for wall–window, ceiling–wall, wall–floor joints for the numerical calculation. For each setup, the temperature distribution and overall heat transferred through the building elements were calculated. Different thermal bridge designs have a significant influence on the overall heat transfer, and by choosing the optimal design, the transmission heat losses can be reduced by up to 67%. Full article
(This article belongs to the Section G: Energy and Buildings)
Show Figures

Figure 1

19 pages, 6871 KB  
Article
Numerical Analysis of Natural Ventilation on One Side of a Room with Two Different Opening Configurations
by Zhicheng Fang, Wanjiang Wang, Yanhui Chen, Hui Fan, Ruoqi Dong, Dongbing Pang and Junkang Song
Sustainability 2023, 15(14), 11456; https://doi.org/10.3390/su151411456 - 24 Jul 2023
Viewed by 3756
Abstract
Single-side natural ventilation is a commonly used means of ventilation to effectively regulate the thermal environment in building interiors without any fossil energy consumption. To achieve most of the potential for the efficiency of single-side natural ventilation, research needs to be undertaken into [...] Read more.
Single-side natural ventilation is a commonly used means of ventilation to effectively regulate the thermal environment in building interiors without any fossil energy consumption. To achieve most of the potential for the efficiency of single-side natural ventilation, research needs to be undertaken into the forces that drive single-side natural ventilation. This paper examines the single-side natural ventilation of a single vertical single opening (SSO) and a vertical double opening (SDO) in a freestanding building under wind and thermal pressure. The change in the trajectory of vortex shedding when the building is leeward as well as the frequency of vortex shedding in square buildings was investigated by large eddy simulation (LES), and computational fluid dynamics was used to analyze the difference in the air exchange rate of single-side natural ventilation of SSO and SDO in the windward and leeward conditions of the building. Both of these methods were used in conjunction with one another. According to the findings, the creation of vortices at SSO and SDO in the presence of low wind speeds reduces the ventilation effect of thermal pressure under windward circumstances. Consequently, the influence of thermal stress and wind stress ultimately cancel each other out, and this phenomenon finally disappears as the wind blowing from the outside of the structure increases. The shedding of vortices in the leeward state accomplishes a form of air supply pumping with a particular periodicity of airflow fluctuations in the lateral direction. The Strouhal number computed using the LES simulation acts in a manner consistent with the experimental findings. Full article
(This article belongs to the Topic Building Energy Efficiency)
Show Figures

Figure 1

Back to TopTop