Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (1,743)

Search Parameters:
Keywords = frequency transient

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 1053 KB  
Article
Symmetry-Guided Numerical Simulation of Viscoelastic Pipe Leakage Based on Transient Inverse Problem Analysis
by Tian-Yu Zhang, Ying Xu, Yu-Chao Ma and Jian-Feng Qian
Symmetry 2025, 17(11), 1805; https://doi.org/10.3390/sym17111805 (registering DOI) - 26 Oct 2025
Abstract
In this study, numerical simulations were performed, and leaks in viscoelastic pipelines were detected. Based on the transient flow equations derived from the continuity and momentum equations, the Kelvin–Voigt model was used to describe the viscoelastic constitutive relationship and derive the strain equation, [...] Read more.
In this study, numerical simulations were performed, and leaks in viscoelastic pipelines were detected. Based on the transient flow equations derived from the continuity and momentum equations, the Kelvin–Voigt model was used to describe the viscoelastic constitutive relationship and derive the strain equation, further establishing a one-dimensional transient flow model for viscoelastic pipelines. A frequency-domain analysis of the transient flow was performed by deriving the Fourier transform and transfer matrix. An inverse problem analysis method for transient flow leak detection was proposed to identify the leak location and rate by minimizing the objective function. To verify the effectiveness of the proposed model, an experimental platform was built, and the pressure head frequency-domain data under working conditions of no leak, experimental leak, and simulated leak were compared. The results showed that the experimental data were consistent with the simulated data under leakage conditions, thus proving that the model was accurate and reliable. Under leak-free conditions, the frequency-domain characteristics of transient pressure waves exhibit significant symmetrical features, whereas when a leak exists in the pipeline, the leak point acts as a localized non-uniform disturbance source, disrupting the symmetry of the frequency-domain characteristics. Moreover, the leak point can be determined by the difference in the peak heights between the no-leak and leak conditions, and the leak parameters can be accurately identified using the inverse problem method. Full article
(This article belongs to the Section Engineering and Materials)
Show Figures

Figure 1

41 pages, 4380 KB  
Article
A Two-Layer HiMPC Planning Framework for High-Renewable Grids: Zero-Exchange Test on Germany 2045
by Alexander Blinn, Joshua Bunner and Fabian Kennel
Energies 2025, 18(21), 5579; https://doi.org/10.3390/en18215579 - 23 Oct 2025
Viewed by 111
Abstract
High-renewables grids are planned in min but judged in milliseconds; credible studies must therefore resolve both horizons within a single model. Current adequacy tools bypass fast frequency dynamics, while detailed simulators lack multi-hour optimization, leaving investors without a unified basis for sizing storage, [...] Read more.
High-renewables grids are planned in min but judged in milliseconds; credible studies must therefore resolve both horizons within a single model. Current adequacy tools bypass fast frequency dynamics, while detailed simulators lack multi-hour optimization, leaving investors without a unified basis for sizing storage, shifting demand, or upgrading transfers. We present a two-layer Hierarchical Model Predictive Control framework that links 15-min scheduling with 1-s corrective action and apply it to Germany’s four TSO zones under a stringent zero-exchange stress test derived from the NEP 2045 baseline. Batteries, vehicle-to-grid, pumped hydro and power-to-gas technologies are captured through aggregators; a decentralized optimizer pre-positions them, while a fast layer refines setpoints as forecasts drift; all are subject to inter-zonal transfer limits. Year-long simulations hold frequency within ±2 mHz for 99.9% of hours and below ±10 mHz during the worst multi-day renewable lull. Batteries absorb sub-second transients, electrolyzers smooth surpluses, and hydrogen turbines bridge week-long deficits—none of which violate transfer constraints. Because the algebraic core is modular, analysts can insert new asset classes or policy rules with minimal code change, enabling policy-relevant scenario studies from storage mandates to capacity-upgrade plans. The work elevates predictive control from plant-scale demonstrations to system-level planning practice. It unifies adequacy sizing and dynamic-performance evaluation in a single optimization loop, delivering an open, scalable blueprint for high-renewables assessments. The framework is readily portable to other interconnected grids, supporting analyses of storage obligations, hydrogen roll-outs and islanding strategies. Full article
26 pages, 13054 KB  
Article
Intelligent Frequency Control for Hybrid Multi-Source Power Systems: A Stepwise Expert-Teaching PPO Approach
by Jianhong Jiang, Shishu Zhang, Jie Wang, Wenting Shen, Changkui Xue, Qiang Ye, Zhaoyang Lv, Minxing Xu and Shihong Miao
Processes 2025, 13(11), 3396; https://doi.org/10.3390/pr13113396 - 23 Oct 2025
Viewed by 64
Abstract
This paper proposes a stepwise expert-teaching reinforcement learning framework for intelligent frequency control in hydro–thermal–wind–solar–compressed air energy storage (CAES) integrated systems under high renewable energy penetration. The proposed method addresses the frequency stability challenge in low-inertia, high-volatility power systems, particularly in Southwest China, [...] Read more.
This paper proposes a stepwise expert-teaching reinforcement learning framework for intelligent frequency control in hydro–thermal–wind–solar–compressed air energy storage (CAES) integrated systems under high renewable energy penetration. The proposed method addresses the frequency stability challenge in low-inertia, high-volatility power systems, particularly in Southwest China, where large-scale renewable-energy-based energy bases are rapidly emerging. A load frequency control (LFC) model is constructed to serve as the training and validation environment, reflecting the dynamic characteristics of the hybrid system. The stepwise expert-teaching PPO (SETP) framework introduces a stepwise training mechanism in which expert knowledge is embedded to guide the policy learning process and training parameters are dynamically adjusted based on observed performance. Comparative simulations under multiple disturbance scenarios are conducted on benchmark systems. Results show that the proposed method outperforms standard proximal policy optimization (PPO) and traditional PI control in both transient response and coordination performance. Full article
28 pages, 8199 KB  
Article
Vibration Characteristics of a Beam with Elastic Time-Varying Stiffness Boundaries
by Zhiwei Guo, Yu Zhang, Meiping Sheng, Leilei Liu and Yinling Li
Appl. Sci. 2025, 15(21), 11365; https://doi.org/10.3390/app152111365 - 23 Oct 2025
Viewed by 145
Abstract
In a conventional elastic beam with steady boundary stiffness, vibrational energy tends to concentrate at specific modal frequencies, often resulting in significant resonance phenomena. To address this issue, a novel control strategy is proposed in this study, in which the stiffness of boundary [...] Read more.
In a conventional elastic beam with steady boundary stiffness, vibrational energy tends to concentrate at specific modal frequencies, often resulting in significant resonance phenomena. To address this issue, a novel control strategy is proposed in this study, in which the stiffness of boundary springs is dynamically modulated to alter the resonance characteristics of the beam. The Newmark–Beta method is employed to compute the transient response of the beam with time-varying stiffness in the time domain. A series of numerical simulations is conducted to analyze the vibration behavior of the structure under single-model frequency, multimodal frequency, narrowband, and broadband random excitations. The results indicate that time-varying stiffness effectively redistributes energy from resonance frequencies to other frequency bands, thereby suppressing resonance peaks and reducing displacement amplitudes. Furthermore, parametric analysis reveals that increasing the range of stiffness variation enhances spectral dispersion and improves vibration attenuation performance, and increasing the average stiffness level helps improve energy dispersion; however, it may lead to a slight increase in vibration response at low frequencies. Full article
(This article belongs to the Special Issue Novel Advances in Noise and Vibration Control)
Show Figures

Figure 1

14 pages, 4214 KB  
Article
High-Efficiency Wide-Bandwidth Boost Converter IC with Pulse-Skipped Switching and Gm-Boosted Compensation for Battery-Powered Portable Systems
by Woojin Kim, Haejun Noh, Se-Un Shin and Hyuntak Jeon
Energies 2025, 18(21), 5575; https://doi.org/10.3390/en18215575 - 23 Oct 2025
Viewed by 143
Abstract
High-efficiency power management is essential for silicon photomultiplier (SiPM)-based sensing systems, especially in portable radiation detectors that demand long battery life and stable operation. Conventional fixed-frequency, voltage-mode boost converters face two critical issues: efficiency degradation at light load due to dominant switching losses, [...] Read more.
High-efficiency power management is essential for silicon photomultiplier (SiPM)-based sensing systems, especially in portable radiation detectors that demand long battery life and stable operation. Conventional fixed-frequency, voltage-mode boost converters face two critical issues: efficiency degradation at light load due to dominant switching losses, and narrow loop bandwidth in discontinuous conduction mode (DCM), which limits transient response. This work proposes a boost converter IC that integrates a pulse-skipped switching (PSS) scheme with a Gm-boosted compensator to address these challenges. The PSS method adaptively suppresses unnecessary switching events, significantly improving light-load efficiency, while the Gm-boosted compensator enhances loop gain, expanding the bandwidth and enabling faster recovery under dynamic conditions. Implemented in a 250 nm BCD process, the converter provides up to 30 V output from a 3.3–5 V supply with load currents up to 10 mA. Simulation results show a peak efficiency of 86.3% at 1 mA and a loop bandwidth increase of more than 14 times compared with a conventional fixed-frequency, voltage-mode design. Beyond radiation applications, the proposed converter is broadly applicable to battery-powered IoT, medical monitoring, and portable energy systems requiring efficient high-voltage generation. Full article
(This article belongs to the Section D2: Electrochem: Batteries, Fuel Cells, Capacitors)
Show Figures

Figure 1

17 pages, 12379 KB  
Article
Black-Box Modeling for Investigating Internal Resonances in High-Voltage Windings of Dry-Type Transformers
by Felipe L. Probst and Stefan Tenbohlen
Energies 2025, 18(21), 5565; https://doi.org/10.3390/en18215565 - 22 Oct 2025
Viewed by 146
Abstract
Understanding internal resonance phenomena in transformer windings is essential for evaluating insulation performance and preventing equipment failure under transient conditions. This study presents a measurement-based modeling approach to assess internal voltage distributions in a high-voltage transformer winding of a dry-type distribution transformer. Frequency-domain [...] Read more.
Understanding internal resonance phenomena in transformer windings is essential for evaluating insulation performance and preventing equipment failure under transient conditions. This study presents a measurement-based modeling approach to assess internal voltage distributions in a high-voltage transformer winding of a dry-type distribution transformer. Frequency-domain admittance and voltage transfer functions were experimentally obtained and approximated using vector fitting. The resulting models were employed to simulate time-domain responses through a two-step procedure that integrates electromagnetic transient simulations of the terminal circuit with frequency-derived internal voltage models. The validation was performed using a sinusoidal excitation at 51 kHz, corresponding to the first-mode resonance frequency. Simulated internal voltages and input currents showed close agreement with experimental measurements, confirming the model’s accuracy. The study identified two critical resonance frequencies at 51 kHz and 59 kHz, at which voltage amplification can become severe. At 51 kHz, the maximum overvoltage reached nearly seven times the applied voltage at the winding midpoint, indicating a substantial risk of dielectric failure. These findings highlight the importance of accurately characterizing internal resonances in transformer windings, especially during insulation coordination studies. The proposed methodology offers an effective tool for analyzing internal overvoltages and contributes to the development of more robust transformer design and protection strategies. Full article
Show Figures

Figure 1

21 pages, 7994 KB  
Article
Power Analysis Produced by Virtual Inertia in Single-Phase Grid-Forming Converters Under Frequency Events Intended for Bidirectional Battery Chargers
by Erick Pantaleon, Jhonatan Paucara and Damián Sal y Rosas
Energies 2025, 18(21), 5560; https://doi.org/10.3390/en18215560 - 22 Oct 2025
Viewed by 192
Abstract
The widespread integration of renewable energy sources (RESs) into the grid through inertia-less power converters is reducing the overall system inertia leading to large frequency variations. To mitigate this issue, grid-forming (GFM) control strategies in bidirectional battery chargers have emerged as a promising [...] Read more.
The widespread integration of renewable energy sources (RESs) into the grid through inertia-less power converters is reducing the overall system inertia leading to large frequency variations. To mitigate this issue, grid-forming (GFM) control strategies in bidirectional battery chargers have emerged as a promising solution, since the inertial response of synchronous generators (SGs) can be emulated by power converters. However, unlike SGs, which can withstand currents above their rated values, the output current of a power converter is limited to its nominal design value. Therefore, the estimation of the power delivered by the GFM power converter during frequency events, called Virtual Inertia (VI) support, is essential to prevent exceeding the rated current. This article analyzes the VI response of GFM power converters, classifying the dynamic behavior as underdamped, critically damped, or overdamped according to the selected inertia constant and damping coefficient, parameters of the GFM control strategy. Subsequently, the transient power response under step-shaped and ramp-shaped frequency deviations is quantified. The proposed analysis is validated using a 1.2 KW single-phase power converter. The simulation and experimental results confirm that the overdamped response under a ramp-shaped frequency event shows higher fidelity to the theorical model. Full article
Show Figures

Figure 1

14 pages, 929 KB  
Article
Acute Effects of Complex Hand Proprioceptive Task on Low-Frequency Hand Rest Tremor
by Francesca Di Rocco, Emanuel Festino, Olga Papale, Marianna De Maio, Cristina Cortis and Andrea Fusco
Sensors 2025, 25(20), 6502; https://doi.org/10.3390/s25206502 - 21 Oct 2025
Viewed by 322
Abstract
Resting hand tremor is a low-frequency, involuntary oscillation influenced by mechanical and neural factors, often manifesting as inter-limb asymmetry. Therefore, the aim of this study was to investigate whether a single complex hand proprioceptive task can acutely modulate tremor in healthy young adults [...] Read more.
Resting hand tremor is a low-frequency, involuntary oscillation influenced by mechanical and neural factors, often manifesting as inter-limb asymmetry. Therefore, the aim of this study was to investigate whether a single complex hand proprioceptive task can acutely modulate tremor in healthy young adults and whether it can induce asymmetry between limbs. Fifty participants (age: 25.0 ± 2.5 years) completed a 40-min proprioceptive task (anteroposterior, mediolateral, clockwise, and counterclockwise), with bilateral resting tremor recorded via triaxial accelerometry before and immediately after the intervention on both dominant and non-dominant limbs. Frequency-domain analysis showed a significant (p < 0.001) increase in tremor amplitude and a small decrease in mean frequency in the 2–4 Hz band immediately after the complex hand proprioceptive task for both limbs. These findings provide novel evidence that a single, wearable-based protocol can transiently modulate tremor dynamics, supporting the use of a non-invasive tool for neuromuscular monitoring in sport, rehabilitation, and clinical practice. Full article
(This article belongs to the Special Issue Wearable Sensors and Human Activity Recognition in Health Research)
Show Figures

Figure 1

19 pages, 3339 KB  
Article
Sensorless Control of Permanent Magnet Synchronous Motor in Low-Speed Range Based on Improved ESO Phase-Locked Loop
by Minghao Lv, Bo Wang, Xia Zhang and Pengwei Li
Processes 2025, 13(10), 3366; https://doi.org/10.3390/pr13103366 - 21 Oct 2025
Viewed by 270
Abstract
Aiming at the speed chattering problem caused by high-frequency square wave injection in permanent magnet synchronous motors (PMSMs) during low-speed operation (200–500 r/min), this study intends to improve the rotor position estimation accuracy of sensorless control systems as well as the system’s ability [...] Read more.
Aiming at the speed chattering problem caused by high-frequency square wave injection in permanent magnet synchronous motors (PMSMs) during low-speed operation (200–500 r/min), this study intends to improve the rotor position estimation accuracy of sensorless control systems as well as the system’s ability to resist harmonic interference and sudden load changes. The goal is to enhance the control performance of traditional control schemes in this scenario and meet the requirement of stable low-speed operation of the motor. First, the study analyzes the harmonic error propagation mechanism of high-frequency square wave injection and finds that the traditional PI phase-locked loop (PI-PLL) is susceptible to high-order harmonic interference during demodulation, which in turn leads to position estimation errors and periodic speed fluctuations. Therefore, the extended state observer phase-locked loop (ESO-PLL) is adopted to replace the traditional PI-PLL. A third-order extended state observer (ESO) is used to uniformly regard the system’s unmodeled dynamics, external load disturbances, and harmonic interference as “total disturbances”, realizing real-time estimation and compensation of disturbances, and quickly suppressing the impacts of harmonic errors and sudden load changes. Meanwhile, a dynamic pole placement strategy for the speed loop is designed to adaptively adjust the controller’s damping ratio and bandwidth parameters according to the motor’s operating states (loaded/unloaded, steady-state/transient): large poles are used in the start-up phase to accelerate response, small poles are switched in the steady-state phase to reduce errors, and a smooth attenuation function is used in the transition phase to achieve stable parameter transition, balancing the system’s dynamic response and steady-state accuracy. In addition, high-frequency square wave voltage signals are injected into the dq axes of the rotating coordinate system, and effective rotor position information is extracted by combining signal demodulation with ESO-PLL to realize decoupling of high-frequency response currents. Verification through MATLAB/Simulink simulation experiments shows that the improved strategy exhibits significant advantages in the low-speed range of 200–300 r/min: in the scenario where the speed transitions from 200 r/min to 300 r/min with sudden load changes, the position estimation curve of ESO-PLL basically overlaps with the actual curve, while the PI-PLL shows obvious deviations; in the start-up and speed switching phases, dynamic pole placement enables the motor to respond quickly without overshoot and no obvious speed fluctuations, whereas the traditional fixed-pole PI control has problems of response lag or overshoot. In conclusion, the “ESO-PLL + dynamic pole placement” cooperative control strategy proposed in this study effectively solves the problems of harmonic interference and load disturbance caused by high-frequency square wave injection in the low-speed range and significantly improves the accuracy and robustness of PMSM sensorless control. This strategy requires no additional hardware cost and achieves performance improvement only through algorithm optimization. It can be directly applied to PMSM control systems that require stable low-speed operation, providing a reliable solution for the promotion of sensorless control technology in low-speed precision fields. Full article
Show Figures

Figure 1

23 pages, 1684 KB  
Article
Method of Accelerated Low-Frequency Oscillation Analysis in Low-Inertia Power Systems Based on Orthogonal Decomposition
by Mihail Senyuk, Svetlana Beryozkina, Ismoil Odinaev, Inga Zicmane and Murodbek Safaraliev
Electronics 2025, 14(20), 4105; https://doi.org/10.3390/electronics14204105 - 20 Oct 2025
Viewed by 200
Abstract
The peculiarity of the functioning of modern electric power systems, caused by the presence of renewable energy sources, flexible control devices based on power electronics, and the reduction of the reserve of the transmission capacity of the electric network, increases the relevance of [...] Read more.
The peculiarity of the functioning of modern electric power systems, caused by the presence of renewable energy sources, flexible control devices based on power electronics, and the reduction of the reserve of the transmission capacity of the electric network, increases the relevance of identifying and damping low-frequency oscillations (LFOs) of the electrical mode. This paper presents a comparative analysis of methods for estimating the parameters of low-frequency oscillations. Their applicability limits are shown as well as their peculiarity associated with low adaptability, and time costs in assessing the parameters of the electrical mode with low-frequency oscillations are revealed. A method for the accelerated evaluation of low-frequency oscillation parameters is proposed, the delay of which is ¼ of the oscillation cycle. The method was tested on both synthetic and physical signals. In the first case, the source of data was a four-machine mathematical model of a power system. In the second case, signals of transient processes occurring in a real power system were used as physical data. The accuracy of the proposed method was obtained by calculating the difference between the original and reconstructed signals. As a result, calculated error values were obtained, describing the accuracy and efficiency of the proposed method. The proposed algorithm for estimating LFO parameters displayed an error value not exceeding 0.8% for both synthetic and physical data. Full article
Show Figures

Figure 1

15 pages, 1629 KB  
Article
Networking Strategy of Small Hydropower Microgrid Under Weak Communication Conditions
by Zhifeng Chen, Zifan Zhang, Zhanhong Liang, Yuan Tang and Na Shen
Energies 2025, 18(20), 5518; https://doi.org/10.3390/en18205518 - 20 Oct 2025
Viewed by 174
Abstract
Small hydropower-dominated microgrids enable power exchange with the main grid during grid-connected operation but face frequency stability challenges during sudden islanding (e.g., line faults), requiring prompt generation curtailment or load shedding. In communication-constrained mountainous regions, conventional methods such as high-frequency tripping or low-frequency [...] Read more.
Small hydropower-dominated microgrids enable power exchange with the main grid during grid-connected operation but face frequency stability challenges during sudden islanding (e.g., line faults), requiring prompt generation curtailment or load shedding. In communication-constrained mountainous regions, conventional methods such as high-frequency tripping or low-frequency load shedding often struggle to achieve precise frequency regulation A hierarchical strategy integrating master station centralized decision making and substation local control is proposed. This study theoretically analyzes the post-islanding frequency dynamics of small hydropower microgrids. The master station formulates optimal shedding decisions using regional power flow data, while substations execute decisions via local measurements to mitigate communication issues. A constrained mathematical model is established, solved using a heuristic algorithm, validated through electromagnetic transient simulations, and compared with traditional schemes. The proposed scheme achieves precise surplus capacity shedding, enhancing frequency stability during abrupt islanding with reduced over-/under-tripping compared to that of conventional methods. This hierarchical strategy enhances frequency regulation capability under communication constraints, ensuring reliable operation of small hydropower microgrids during sudden islanding and providing a practical solution for remote regions with limited communication infrastructure. Full article
Show Figures

Figure 1

27 pages, 2211 KB  
Article
HVDC Receiving-End Power Grid Multi-Resource Coordinated Transient Voltage Emergency Control Technology Based on Transient Voltage Similarity
by Xu Ling, Jianghui Xi, Qiuting Guo, Xiaodong Yu and Xiongguang Zhao
Electronics 2025, 14(20), 4090; https://doi.org/10.3390/electronics14204090 - 17 Oct 2025
Viewed by 229
Abstract
This study addresses the issues related to the inaccurate assessment of transient voltage stability margins and the limited participation of resources involved in regulation during high-voltage direct current (HVDC) receiving-end grid faults under high-penetration new energy integration. This paper proposes a method for [...] Read more.
This study addresses the issues related to the inaccurate assessment of transient voltage stability margins and the limited participation of resources involved in regulation during high-voltage direct current (HVDC) receiving-end grid faults under high-penetration new energy integration. This paper proposes a method for transient voltage emergency control at the HVDC receiving-end grid, utilizing a multi-resource approach based on transient voltage similarity partitioning with a multiple-two-element notation criterion. First, the transient voltage stability margin and the new energy transient off-grid margin index, based on the multiple-two-element notation criterion, are introduced. Second, a grid partitioning scheme is employed, which clusters nodes based on the similarity of their transient voltage features, and the impact of multiple resources on the transient voltage stability of the HVDC receiving-end system is analyzed using trajectory sensitivity. On this basis, a multi-resource optimization model for transient voltage emergencies is established with the aim of minimizing the control cost, considering the transient voltage stability, off-grid new energy, and other safety evaluation constraints, in order to coordinate multiple resources participating in transient voltage control until the stability requirements are met. Finally, the validity of the proposed control scheme is verified using the improved frequency stability benchmark test system (Chinese Society for Electrical Engineering—Frequency Stability, CSEE-FS). The research results demonstrate that the scheme proposed in this study can be utilized to accurately assess the transient voltage stability and off-grid potential of renewable energy units following failure at the HVDC receiving-end system. Additionally, it can reasonably partition the grid based on transient operating conditions while fully exploiting the potential of multiple resources within the faulted partition to control transient voltage emergencies in the grid. Full article
Show Figures

Figure 1

29 pages, 6302 KB  
Article
Measurement of Strain and Vibration, at Ambient Conditions, on a Dynamically Pressurised Aircraft Fuel Pump Using Optical Fibre Sensors
by Edmond Chehura, Stephen W. James, Jarryd Braithwaite, James H. Barrington, Stephen Staines, Andrew Keil, Martin Yates, Nicholas John Lawson and Ralph P. Tatam
Sensors 2025, 25(20), 6407; https://doi.org/10.3390/s25206407 - 17 Oct 2025
Viewed by 336
Abstract
Ever-increasing demands to improve fuel burn efficiency of aero gas turbines lead to rises in fuel system pressures and temperatures, posing challenges for the structural integrity of the pump housing and creating internal deflections that can adversely affect volumetric efficiency. Non-invasive strain and [...] Read more.
Ever-increasing demands to improve fuel burn efficiency of aero gas turbines lead to rises in fuel system pressures and temperatures, posing challenges for the structural integrity of the pump housing and creating internal deflections that can adversely affect volumetric efficiency. Non-invasive strain and vibration measurements could allow transient effects to be quantified and considered during the design process, leading to more robust fuel pumps. Fuel pumps used on a high bypass turbofan engine were instrumented with optical fibre Bragg grating (FBG) sensors, strain gauges and thermocouples. A hydraulic hand pump was used to facilitate measurements under static conditions, while dynamic measurements were performed on a dedicated fuel pump test rig. The experimental data were compared with the outputs from a finite element (FE) model and, in general, good agreement was observed. Where differences were observed, it was concluded that they arose from the sensitivity of the model to the selection of nodes that best matched the sensor location. Strain and vibration measurements were performed over the frequency range of 0 to 2.5 kHz and demonstrated the ability of surface-mounted FBGs to characterise vibrations originating within the internal sub-components of the pump, offering potential for condition monitoring. Full article
(This article belongs to the Special Issue Feature Papers in Optical Sensors 2025)
Show Figures

Figure 1

26 pages, 12326 KB  
Article
A Study on Energy Loss and Transient Flow Characteristics of a Large Volute Centrifugal Pump During Power-Off Process Under Cavitation Conditions
by Qingzhao Pang, Desheng Zhang, Gang Yang, Xi Shen, Qiang Pan, Linlin Geng and Qinghui Lu
J. Mar. Sci. Eng. 2025, 13(10), 1973; https://doi.org/10.3390/jmse13101973 - 15 Oct 2025
Viewed by 268
Abstract
A novel pumped storage system using centrifugal pumps to transfer water between reservoirs in coastal hydropower plants has significantly mitigated grid instability. However, frequent start–stop operations of large vertical centrifugal pumps, which serve as the core equipment, severely affect the operational stability of [...] Read more.
A novel pumped storage system using centrifugal pumps to transfer water between reservoirs in coastal hydropower plants has significantly mitigated grid instability. However, frequent start–stop operations of large vertical centrifugal pumps, which serve as the core equipment, severely affect the operational stability of these systems. In this study, the intrinsic connection between the cavitating flow field and irreversible losses during the process was analyzed using the entropy production theory. The time–frequency characteristics of pressure pulsation in pump were analyzed by using the continuous wavelet transform. The results indicate that with the reduction in the flow rate and rotational speed, the sheet cavitation at the impeller inlet rapidly weakens until it vanishes. The cavity cavitation within the draft tube commences to emerge in the turbine mode. Separation vortices are formed due to the mismatch in the flow angle at the impeller outlet. These vortices induce local cavitation, causing both a rapid energy loss increase and high-amplitude, low-frequency pressure pulsations. During transient processes, flow instabilities induce high-amplitude, low-frequency pressure pulsations within the stay vane region, with maximum amplitude attained during runaway condition. The research results provide a theoretical foundation for the stable operation of centrifugal pumps. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

13 pages, 1543 KB  
Article
Comparative Study on Modulation of Synchronized Neuronal Activity by SK Channels and Na/K-ATPase
by Dmitry A. Sibarov, Sergei I. Boikov, Tatiana V. Karelina, Vadim V. Yushko, Alyona I. Fedorina and Sergei M. Antonov
Int. J. Mol. Sci. 2025, 26(20), 10004; https://doi.org/10.3390/ijms262010004 - 14 Oct 2025
Viewed by 160
Abstract
Drug-resistant epilepsy remains a therapeutic challenge, requiring new molecular targets beyond conventional antiepileptic drugs. Small-conductance calcium-activated potassium (SK) channels and Na/K-ATPase (NKA) contribute to afterhyperpolarization via distinct mechanisms, offering complementary ways to suppress hyperexcitability. We examined SK activation and NKA modulation in synchronized [...] Read more.
Drug-resistant epilepsy remains a therapeutic challenge, requiring new molecular targets beyond conventional antiepileptic drugs. Small-conductance calcium-activated potassium (SK) channels and Na/K-ATPase (NKA) contribute to afterhyperpolarization via distinct mechanisms, offering complementary ways to suppress hyperexcitability. We examined SK activation and NKA modulation in synchronized epileptiform activity in a primary culture of cortical neurons obtained from rat embryos. Epileptiform discharges were induced by magnesium-free solution and assessed by patch-clamp and calcium imaging. The SK2/3 activator CyPPA (10 µM) reduced epileptiform current (EC) amplitude and integral and decreased synchronized calcium transient (CT) frequency but gradually elevated basal calcium. In contrast, ouabain (1 nM), a selective modulator of high-affinity NKA isoforms, attenuated EC amplitude, strongly suppressed CTs, and showed persistent effects after washout, accompanied by asynchronous glial calcium activity. Co-application of CyPPA with ouabain abolished CyPPA-induced calcium elevation while maintaining suppression of neuronal synchrony. The broader SK/IK activator NS309 (10 µM) reduced CT frequency and basal calcium without affecting glia. Thus, SK activation and NKA signaling suppress epileptiform synchronization through distinct yet convergent pathways: SK channels via afterhyperpolarization and NKA via afterhyperpolarization and calcium-dependent signaling. Their combination enhances efficacy and prevents adverse calcium buildup, supporting SK–NKA co-targeting as a strategy against drug-resistant epilepsy. Full article
(This article belongs to the Special Issue Advances in Epilepsy and Antiepileptic Drugs, 3rd Edition)
Show Figures

Figure 1

Back to TopTop