Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (347)

Search Parameters:
Keywords = dental abutment

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 3998 KiB  
Article
Promoting Surface Energy and Osteoblast Viability on Zirconia Implant Abutments Through Glass–Ceramic Spray Deposition Technology
by Wen-Chieh Hsu, Tao-Yu Cha, Yu-Chin Yao, Chien-Ming Kang, Sheng-Han Wu, Yuichi Mine, Chien-Fu Tseng, I-Ta Lee, Dan-Jae Lin and Tzu-Yu Peng
J. Funct. Biomater. 2025, 16(8), 288; https://doi.org/10.3390/jfb16080288 - 7 Aug 2025
Abstract
Zirconia is used widely for high-precision custom abutments; however, stress concentration can compromise osseointegration. Although glass–ceramic spray deposition (GCSD) can enhance the surface properties of zirconia, its biological effects remain unclear. In this study, the biological responses of human osteoblast-like (MG-63) cells to [...] Read more.
Zirconia is used widely for high-precision custom abutments; however, stress concentration can compromise osseointegration. Although glass–ceramic spray deposition (GCSD) can enhance the surface properties of zirconia, its biological effects remain unclear. In this study, the biological responses of human osteoblast-like (MG-63) cells to GCSD-modified zirconia surfaces were evaluated to assess the potential application in zirconia abutments. Disk-shaped zirconia and titanium alloy samples were prepared; titanium served as the control (Ti). Zirconia was subjected to polishing (NT), airborne-particle abrasion (AB), or GCSD with (GE) or without (GC) hydrofluoric acid (HF) etching. Surface characteristics, including wettability, surface energy (SE), and surface potential (SP), were analyzed. Cytotoxicity and MG-63 cell adhesion were assessed using the PrestoBlue assay, scanning electron microscopy (SEM), viability staining, and confocal laser scanning microscopy (CLSM). Statistical analysis was performed with a significance level of 0.05. GCSD produced a dense glass–ceramic coating on the zirconia surface, which significantly enhanced hydrophilicity as indicated by reduced water contact angles and increased SE in the GC and GE groups (p < 0.05). HF etching increased SP (p < 0.05). No cytotoxicity was observed in any group. SEM, viability staining, and CLSM revealed enhanced MG-63 cell attachment on Ti and GE surfaces and the highest viability ratio in the GE group. The NT group exhibited the lowest cell attachment and viability at all time points. GCSD effectively improved zirconia abutment surface properties by enhancing hydrophilicity and promoting MG-63 cell adhesion, with biocompatibility comparable to or better than that of titanium. Full article
Show Figures

Figure 1

18 pages, 11273 KiB  
Article
The Effect of Different Tightening Torques of Implant Cone Morse Abutment Connection Under Dynamic Fatigue Loading: An In Vitro Study
by Felice Lorusso, Antonio Scarano, Sergio Rexhep Tari, Ishita Singhal, Funda Goker, Maria Costanza Soldini, Gianluca Martino Tartaglia and Massimo Del Fabbro
Biomimetics 2025, 10(8), 511; https://doi.org/10.3390/biomimetics10080511 - 4 Aug 2025
Viewed by 115
Abstract
Background: The implant–abutment joint is important for the long-term marginal tissue integrity in terms of biomimetic design that replicates the natural dentition under mastication forces. This study aimed to evaluate conical implant–abutment joints coupled at different tightening torque values through a mechanical fatigue [...] Read more.
Background: The implant–abutment joint is important for the long-term marginal tissue integrity in terms of biomimetic design that replicates the natural dentition under mastication forces. This study aimed to evaluate conical implant–abutment joints coupled at different tightening torque values through a mechanical fatigue test. Methods: Eighty conic implants (Ø: 3.8 mm L: 10 mm) with a 6° cone morse joint were embedded in resin blocks with an inclination of 30° ± 2°. The samples were divided into 8 groups (4 Test and 4 Control). The implant–abutment joints were coupled with different tightening torques: 25 Ncm (Group I), 30 Ncm (Group II), 35 Ncm (Group III) and 40 Ncm (Group IV). An in vitro cyclic loading test (1 × 104 loads) was performed for 4 Test groups, while 4 Control groups did not receive any forces. All the samples were assessed with Scanning Electron Microscopy to compare the microfractures and microgaps on flexion and extension points. Results: Microscopy observation results showed significant differences among torque groups. We found that 30 Ncm had the best stability with less microgap. Conclusions: Tightening torque plays an important role in the distortion of the cone morse joint under mechanical forces. However, further studies should be conducted to validate the results using different implant–abutment joints for comparison. Full article
Show Figures

Figure 1

22 pages, 9122 KiB  
Article
Computational Mechanics of Polymeric Materials PEEK and PEKK Compared to Ti Implants for Marginal Bone Loss Around Oral Implants
by Mohammad Afazal, Saba Afreen, Vaibhav Anand and Arnab Chanda
Prosthesis 2025, 7(4), 93; https://doi.org/10.3390/prosthesis7040093 - 1 Aug 2025
Viewed by 215
Abstract
Background/Objectives: Dental practitioners widely use dental implants to treat traumatic cases. Titanium implants are currently the most popular choice among dental practitioners and surgeons. The discovery of newer polymeric materials is also influencing the interest of dental professionals in alternative options. A comparative [...] Read more.
Background/Objectives: Dental practitioners widely use dental implants to treat traumatic cases. Titanium implants are currently the most popular choice among dental practitioners and surgeons. The discovery of newer polymeric materials is also influencing the interest of dental professionals in alternative options. A comparative study between existing titanium implants and newer polymeric materials can enhance professionals’ ability to select the most suitable implant for a patient’s treatment. This study aimed to investigate material property advantages of high-performance thermoplastic biopolymers such as PEEK and PEKK, as compared to the time-tested titanium implants, and to find the most suitable and economically fit implant material. Methods: Three distinct implant material properties were assigned—PEEK, PEKK, and commercially pure titanium (CP Ti-55)—to dental implants measuring 5.5 mm by 9 mm, along with two distinct titanium (TI6AL4V) abutments. Twelve three-dimensional (3D) models of bone blocks, representing the mandibular right molar area with Osseo-integrated implants were created. The implant, abutment, and screw were assumed to be linear; elastic, isotropic, and orthotropic properties were attributed to the cancellous and cortical bone. Twelve model sets underwent a three-dimensional finite element analysis to evaluate von Mises stress and total deformation under 250 N vertical and oblique (30 degree) loads on the top surface of each abutment. Results: The study revealed that the time-tested titanium implant outperforms PEEK and PEKK in terms of marginal bone preservation, while PEEK outperforms PEKK. Conclusions: This study will assist dental practitioners in selecting implants from a variety of available materials and will aid researchers in their future research. Full article
Show Figures

Figure 1

15 pages, 1812 KiB  
Article
Influence of Digital Manufacturing and Abutment Design on Full-Arch Implant Prostheses—An In Vitro Study
by Shahad Altwaijri, Hanan Alotaibi, Talal M. Alnassar and Alhanoof Aldegheishem
Materials 2025, 18(15), 3543; https://doi.org/10.3390/ma18153543 - 29 Jul 2025
Viewed by 274
Abstract
Achieving accurate fit in implant-supported prostheses is critical for avoiding mechanical complications; however, the influence of digital manufacturing techniques and abutment designs on misfit and preload remains unclear. This study evaluated the impact of different manufacturing techniques (CAD-cast and 3D printing) and abutment [...] Read more.
Achieving accurate fit in implant-supported prostheses is critical for avoiding mechanical complications; however, the influence of digital manufacturing techniques and abutment designs on misfit and preload remains unclear. This study evaluated the impact of different manufacturing techniques (CAD-cast and 3D printing) and abutment connection types (engaging [E], non-engaging [NE]) on the misfit and preload of implant-supported cantilevered fixed dental prostheses (ICFDPs). Misfit was measured at six points using scanning electron microscopy, and preload was assessed via eight strain gauges placed buccally and lingually on four implants. Frameworks were torqued to 35 Ncm, retorqued after 10 min, and subjected to 200,000 cycles of loading. Mean preload values ranged from 173.4 ± 79.5 Ncm (PF) to 330 ± 253.2 Ncm (3DP). Preload trends varied depending on the abutment type and manufacturing technique, with the 3DP group showing higher preload in engaging (E) abutments, whereas the CAD-cast group showed the opposite pattern. Although preload values varied numerically, these differences were not statistically significant (p = 0.5). In terms of misfit, significant differences were observed between groups (p < 0.05), except between CAD-cast E (86.4 ± 17.8 μm) and 3DP E (84.1 ± 19.2 μm). Additionally, E and NE abutments showed significant differences in misfit within both CAD-cast and 3DP groups. Overall, 3DP frameworks showed superior fit over CAD-cast. These findings suggest that 3DP may offer improved clinical outcomes in terms of implant–abutment fit. Full article
Show Figures

Figure 1

11 pages, 1124 KiB  
Communication
Fracture Resistance of 3D-Printed Fixed Partial Dentures: Influence of Connector Size and Materials
by Giulia Verniani, Edoardo Ferrari Cagidiaco, SeyedReza Alavi Tabatabaei and Alessio Casucci
Materials 2025, 18(15), 3468; https://doi.org/10.3390/ma18153468 - 24 Jul 2025
Viewed by 244
Abstract
Background: Limited data are available regarding the mechanical performance of 3D-printed fixed partial dentures (FPDs) fabricated from different materials and connector geometries. The purpose of this in vitro study was to evaluate the influence of connector size and material type on the fracture [...] Read more.
Background: Limited data are available regarding the mechanical performance of 3D-printed fixed partial dentures (FPDs) fabricated from different materials and connector geometries. The purpose of this in vitro study was to evaluate the influence of connector size and material type on the fracture resistance of three-unit posterior FPDs fabricated with two commercially available 3D-printable dental resins. Methods: A standardized metal model with two cylindrical abutments was used to design three-unit FPDs. A total of sixty samples were produced, considering three connector sizes (3 × 3 mm, 4 × 4 mm, and 5 × 5 mm) and two different resins: Temp Print (GC Corp., Tokyo, Japan) and V-Print c&b temp (Voco GmbH, Cuxhaven, Germany) (n = 10). Specimens were fabricated with a DLP printer (Asiga MAX UV), post-processed per manufacturer recommendations, and tested for fracture resistance under occlusal loading using a universal testing machine. Data were analyzed using nonparametric tests (Mann–Whitney U and Kruskal–Wallis; α = 0.05). Results: Significant differences were found between material and connector size groups (p < 0.001). Temp Print (GC Corp., Tokyo, Japan) demonstrated higher mean fracture loads (792.34 ± 578.36 N) compared to V-Print c&b temp (Voco GmbH, Cuxhaven, Germany) (359.74 ± 131.64 N), with statistically significant differences at 4 × 4 and 5 × 5 mm connectors. Fracture strength proportionally increased with connector size. FPDs with 5 × 5 mm connectors showed the highest resistance, reaching values above 1500 N. Conclusions: Both connector geometry and material composition significantly affected the fracture resistance of 3D-printed FPDs. Larger connector dimensions and the use of Temp Print (GC Corp., Tokyo, Japan) resin enhanced mechanical performance. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Figure 1

13 pages, 4489 KiB  
Article
Fatigue Resistance of Customized Implant-Supported Restorations
by Ulysses Lenz, Renan Brandenburg dos Santos, Megha Satpathy, Jason A. Griggs and Alvaro Della Bona
Materials 2025, 18(14), 3420; https://doi.org/10.3390/ma18143420 - 21 Jul 2025
Viewed by 319
Abstract
The design of custom abutments (CA) can affect the mechanical reliability of implant-supported restorations. The purpose of the study was to evaluate the influence of design parameters on the fatigue limit of CA and to compare optimized custom designs with the reference abutment [...] Read more.
The design of custom abutments (CA) can affect the mechanical reliability of implant-supported restorations. The purpose of the study was to evaluate the influence of design parameters on the fatigue limit of CA and to compare optimized custom designs with the reference abutment (RA). A morse-tapered dental implant, an anatomical abutment, and a connector screw were digitalized using microcomputed tomography. A cone beam computed tomography scan was obtained from one of the authors to virtually place the implant-abutment assembly in the upper central incisor. Ten design parameters were selected according to the structural geometry of the RA and the implant planning. A reverse-engineered RA model was created in SOLIDWORKS and was modified considering a Taguchi orthogonal array to generate 36 CAs with ±20% dimensional variations. Finite element analysis was conducted in ABAQUS, and fatigue limits were estimated using Fe-safe. ANOVA (α = 0.1) identified the most influential parameters. Von Mises stress values ranged from 229 MPa to 302 MPa, and 94.4% of the CAs had a higher fatigue limit than the RA. Three parameters significantly affected the fatigue performance of the implant system. The design process of custom abutments includes critical design parameters that can be optimized for longer lifetimes of implant-abutment restorations. Full article
(This article belongs to the Special Issue Innovations in Digital Dentistry: Novel Materials and Technologies)
Show Figures

Figure 1

12 pages, 2107 KiB  
Article
Assessment of Diameter Stability in Morse Taper Dental Implants with Different Angulations After Abutment Connection
by Bruno Q. S. Cordeiro, Waldimir R. Carvalho, Edgard M. Fonseca, Aldir N. Machado, Bruna Ghiraldini, Michel A. D. Soares and Priscila L. Casado
Materials 2025, 18(14), 3403; https://doi.org/10.3390/ma18143403 - 21 Jul 2025
Viewed by 302
Abstract
Background: Modification of diameter stability after the abutment retention can result in a decrease in the applied torque or affect the peri-implant tissue, compromising the longevity of the treatment. Therefore, this study aimed to investigate how different connection angles (11.5° and 16.0°) at [...] Read more.
Background: Modification of diameter stability after the abutment retention can result in a decrease in the applied torque or affect the peri-implant tissue, compromising the longevity of the treatment. Therefore, this study aimed to investigate how different connection angles (11.5° and 16.0°) at the implant–abutment interface influence implant diameter stability under the manufacturer’s recommended torque. Methods: Eighty Morse cone-type implant specimens were divided into two groups, with different internal conicity angles: 11.5° (n = 40) and 16.0° (n = 40). Implants varied in diameter (mm): 3.5, 3.8, 4.5, and 5.0. Initial measurements of the implants’ external diameter were carried out. After these measurements, all implants received the abutment installation, and a final measurement of the external implant diameter was performed. Results: Considering the comparative analysis between the final and initial diameters, a non-significant increase in diameter, in the cervical implant region, after torque on the abutment, was observed. The torque applied to the abutments did not produce deformations in the cervical area of Morse taper implants. Conclusions: The torque applied to the abutment screw in implants with a Morse taper connection does not cause deformation in the cervical area of the implant body in implant with 11.5° and 16.0° conicity angles. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Figure 1

16 pages, 1741 KiB  
Article
Effect of Crestal Position on Bone–Implant Stress Interface of Three-Implant Splinted Prostheses: A Finite Element Analysis
by Mario Ceddia, Giulia Marchioli, Tea Romasco, Luca Comuzzi, Adriano Piattelli, Douglas A. Deporter, Natalia Di Pietro and Bartolomeo Trentadue
Materials 2025, 18(14), 3344; https://doi.org/10.3390/ma18143344 - 16 Jul 2025
Viewed by 432
Abstract
Optimizing stress distribution at the bone–implant interface is critical to enhancing the long-term biomechanical performance of dental implant systems. Vertical misalignment between splinted implants can result in elevated localized stresses, increasing the risk of material degradation and peri-implant bone resorption. This study employs [...] Read more.
Optimizing stress distribution at the bone–implant interface is critical to enhancing the long-term biomechanical performance of dental implant systems. Vertical misalignment between splinted implants can result in elevated localized stresses, increasing the risk of material degradation and peri-implant bone resorption. This study employs three-dimensional finite element analysis (FEA) to evaluate the mechanical response of peri-implant bone under oblique loading, focusing on how variations in vertical implant platform alignment influence stress transmission. Four implant configurations with different vertical placements were modeled: (A) all crestal, (B) central subcrestal with lateral crestal, (C) lateral subcrestal with central crestal, and (D) all subcrestal. A 400 N oblique load was applied at 45° simulated masticatory forces. Von Mises stress distributions were analyzed in both cortical and trabecular bone, with a physiological threshold of 100 MPa considered for cortical bone. Among the models, configuration B exhibited the highest cortical stress, exceeding the physiological threshold. In contrast, configurations with uniform vertical positioning, particularly model D, demonstrated more favorable stress dispersion and lower peak values. Stress concentrations were consistently observed at the implant–abutment interface across all configurations, identifying this area as critical for design improvements. These findings underscore the importance of precise vertical alignment in implant-supported restorations to minimize stress concentrations and improve the mechanical reliability of dental implants. The results provide valuable insights for the development of next-generation implant systems with enhanced biomechanical integration and material performance under functional loading. Full article
Show Figures

Figure 1

11 pages, 2014 KiB  
Article
Attachment of Human Epithelial Cells to an Anodized Titanium Surface
by Yoshihiko Akashi, Hayato Hashiguchi, Yoshitaka Yamaoka, Kei Nakajima, Katsutoshi Kokubun, Yoshiaki Shimoo and Kenichi Matsuzaka
Materials 2025, 18(14), 3305; https://doi.org/10.3390/ma18143305 - 14 Jul 2025
Viewed by 281
Abstract
The attachment of the oral epithelium to the abutment surface is crucial for the long-term success of dental implants. This study aimed to evaluate the attachment of human epithelial cells to anodized titanium surfaces. Anodized titanium discs were used as the experimental group, [...] Read more.
The attachment of the oral epithelium to the abutment surface is crucial for the long-term success of dental implants. This study aimed to evaluate the attachment of human epithelial cells to anodized titanium surfaces. Anodized titanium discs were used as the experimental group, while machined titanium discs served as the control. Surface roughness and wettability were first measured for each group. Next, human epithelial cells were seeded onto each disc at a density of 4.0 × 104 cells/cm2 and evaluated 3, 6, and 24 h later for cell proliferation, as well as mRNA expression and protein levels of laminin and integrin β4. Surface roughness was comparable between the two groups; however, wettability was significantly higher in the experimental group. Cell proliferation increased over time in both groups and showed no significant difference. Notably, the expression levels of both laminin and integrin β4 were significantly higher in the experimental group at 24 h. Furthermore, protein localization of laminin and integrin β4 was observed along the cell margins on the anodized surface. These findings suggest that anodization enhances epithelial cell attachment by promoting the expression and peripheral organization of key adhesion molecules. Full article
(This article belongs to the Special Issue Advances in Dental Implants and Prosthetics Materials)
Show Figures

Figure 1

13 pages, 5559 KiB  
Article
Effects of Different Titanium Anodized Surfaces on Peri-Implant Soft Tissue Healing Around Dental Abutments: In Vitro and Proteomic Study
by Francisco Romero-Gavilán, Andreia Cerqueira, Carlos Arias-Mainer, David Peñarrocha-Oltra, Claudia Salavert-Martínez, Juan Carlos Bernabeu-Mira, Iñaki García-Arnáez, Félix Elortza, Mariló Gurruchaga, Isabel Goñi and Julio Suay
Appl. Sci. 2025, 15(13), 7349; https://doi.org/10.3390/app15137349 - 30 Jun 2025
Viewed by 308
Abstract
Objectives: This study aimed to evaluate the effects of different titanium (Ti) anodized surfaces on soft tissue healing around dental implant abutments. Methods: Discs of machined (MC), pink anodized (PA) and yellow anodized (YA) surfaces were morphologically characterized and evaluated in vitro. Cell [...] Read more.
Objectives: This study aimed to evaluate the effects of different titanium (Ti) anodized surfaces on soft tissue healing around dental implant abutments. Methods: Discs of machined (MC), pink anodized (PA) and yellow anodized (YA) surfaces were morphologically characterized and evaluated in vitro. Cell adhesion and collagen synthesis by human gingival fibroblasts (hGFs) were assessed to evaluate the regenerative potential of the surfaces under study. Their inflammatory potential was evaluated in THP-1 cell cultures by measuring cytokine secretion, and their proteomic adsorption patterns were characterized using nano-liquid chromatography mass spectrometry (nLC-MS/MS). Statistical significance was considered at 5%. In relation to proteomics, statistical differences were evaluated using the Student t-test with the Perseus application. Results: The anodization process resulted in a reduction in the surface roughness parameter (Ra) relative to the machined titanium (p < 0.05). No differences in hGF adhesion were found between the surfaces after one day. PA induced increased hGF collagen synthesis after 7 days (p < 0.05). The secretion of TNF-α was lower for anodized surfaces than for MC, and its concentration was lower for PA than for YA (p < 0.05). In turn, TGF-β was higher for PA and YA versus MC after one and three days of culture. A total of 176 distinct proteins were identified and 26 showed differences in adhesion between the anodized surfaces and MC. These differential proteins were related to coagulation, lipid metabolism, transport activity, plasminogen activation and a reduction in the immune response. Conclusions: Anodized Ti surfaces showed promising anti-inflammatory and regenerative potential for use in dental implant abutments. Anodization reduced surface roughness, increased collagen synthesis and lowered TNF-α secretion while increasing TGF-β levels compared to machined surfaces. Identified proteins related to coagulation and lipid metabolism supported these findings. Clinical relevance: Anodized surfaces could offer improved short-term peri-implant soft tissue healing over machined surfaces. The analysis of abutment surface, instead of implant surface, is a new approach that can provide valuable information. Full article
(This article belongs to the Special Issue Application of Advanced Therapies in Oral Health)
Show Figures

Figure 1

22 pages, 20537 KiB  
Article
Er:YAG Laser Applications for Debonding Different Ceramic Restorations: An In Vitro Study
by Ruxandra Elena Luca, Anișoara Giumancă-Borozan, Iosif Hulka, Ioana-Roxana Munteanu, Carmen Darinca Todea and Mariana Ioana Miron
Medicina 2025, 61(7), 1189; https://doi.org/10.3390/medicina61071189 - 30 Jun 2025
Viewed by 401
Abstract
Background and Objectives: Conventional methods for removing cemented fixed prosthetic restorations (FPRs) are unreliable and lead to unsatisfactory outcomes. At their best, they allow the tooth to be saved at the expense of a laborious process that also wears down rotating tools [...] Read more.
Background and Objectives: Conventional methods for removing cemented fixed prosthetic restorations (FPRs) are unreliable and lead to unsatisfactory outcomes. At their best, they allow the tooth to be saved at the expense of a laborious process that also wears down rotating tools and handpieces and occasionally results in abutment fractures. Restorations are nearly never reusable in any of these situations. Erbium-doped yttrium-aluminum-garnet (Er:YAG) and erbium-chromium yttrium-scandium-gallium-garnet (Er,Cr:YSGG) lasers casafely and effectively remove FPRs, according to scientific studiesre. This study sets out to examine the impact of Er:YAG laser radiation on the debonding of different ceramic restorations, comparing the behavior of various ceramic prosthetic restoration types under laser radiation action and evaluating the integrity of prosthetic restorations and dental surfaces exposed to laser radiation. Materials and Methods: The study included a total of 16 removed teeth, each prepared on opposite surfaces as abutments.y. Based on the previously defined groups, four types of ceramic restorations were included in the study: feldspathic (F), lithium disilicates (LD), layered zirconia (LZ), and monolithic zirconia (MZ). The thickness of the prosthetic restorations was measured at three points, and two different materials were used for cementation. The Er:YAG Fotona StarWalker MaQX laser was used to debond the ceramic FPR at a distance of 10 mm using an R14 sapphire tip with 275 mJ, 20 Hz, 5.5 W, with air cooling (setting 1 of 9) and water. After debonding, the debonded surface was visualized under electron microscopy. Results: A total of 23 ceramic FPRs were debonded, of which 12 were intact and the others fractured into two or three pieces. The electron microscopy images showed that debonding took place without causing any harm to the tooth structure. The various restoration types had the following success rates: 100% for the LZ and F groups, 87% for the LD group, and 0% for the MZ group. In terms of cement type, debonding ceramic FPRs cemented with RELYX was successful 75% of the time, compared to Variolink DC’s 69% success rate. Conclusions: In summary, the majority of ceramic prosthetic restorations can be successfully and conservatively debonded with Er:YAG radiation. Full article
(This article belongs to the Special Issue Advancements in Dental Medicine, Oral Anesthesiology and Surgery)
Show Figures

Figure 1

17 pages, 17488 KiB  
Article
Effect of Diamond-like Carbon Thin-Film Deposition on the Hardness of Pure Titanium Surfaces
by Hideaki Sato, Yutaka Kameyama, Ryota Yoshikawa, Kaito Tabuchi, Chizuko Ogata and Satoshi Komasa
Materials 2025, 18(13), 2992; https://doi.org/10.3390/ma18132992 - 24 Jun 2025
Viewed by 322
Abstract
The purpose of this study was to clarify the physical durability of a diamond-like carbon (DLC) thin film coated on pure titanium. The titanium surface of the abutment does not have sufficient toughness to prevent an increase in surface roughness or damage when [...] Read more.
The purpose of this study was to clarify the physical durability of a diamond-like carbon (DLC) thin film coated on pure titanium. The titanium surface of the abutment does not have sufficient toughness to prevent an increase in surface roughness or damage when the implant is scaled using a professional mechanical implement. The scaling process used for the removal of the dental plaque adhered to the abutment surface could increase the potential for the deposition of oral microorganisms and the accumulation of plaque, which increase the risk of peri-implantitis. A DLC thin film is biocompatible material that is known for its toughness, including extreme hardness, high abrasion resistance, chemical inertness, and high corrosion resistance. Protecting the abutment surface with the application of a DLC might prevent plaque adhesion due to its non-stick property. There was little change in the surface roughness of titanium samples to which DLC surface protection had been applied when the surface of the sample was scratched with a stainless steel scalar more than a thousand times. When cleaning the surface of pure titanium samples, the surface roughness significantly increased. DLC thin films are effective for the prevention the surface roughness of pure titanium implants from being increased when the conventional cleaning of the surface of the implant is performed. Full article
(This article belongs to the Special Issue Materials for Prosthodontics, Implantology, and Digital Dentistry)
Show Figures

Figure 1

15 pages, 2435 KiB  
Case Report
The First Biological Respect Protocol: A Biodigital Technique for Definitive Customized One-Time Abutments—A Case Report
by Franco Rizzuto and Silvia Rizzuto
J. Clin. Med. 2025, 14(13), 4448; https://doi.org/10.3390/jcm14134448 - 23 Jun 2025
Viewed by 352
Abstract
Background/Objectives: Dental implants represent a viable solution for replacing missing teeth; however, multiple disconnections and reconnections of intermediate abutments contribute to the apical displacement of the peri-implant connective tissue barrier, resulting in additional marginal bone loss. To the best of our knowledge, no [...] Read more.
Background/Objectives: Dental implants represent a viable solution for replacing missing teeth; however, multiple disconnections and reconnections of intermediate abutments contribute to the apical displacement of the peri-implant connective tissue barrier, resulting in additional marginal bone loss. To the best of our knowledge, no definitive customized abutments currently exist that are specifically designed according to the morphology of the tooth to be replaced and its position within the dental arch, allowing for digital planning within the prosthetic implant design and insertion during the surgical procedure without subsequent disconnection. Methods: The First Biological Respect (FR) technique, described in this case report, enables the digital planning not only of the implant but also of the patented FR customized-shaped, definitive abutment and associated FR prosthetic components. The FR technique was applied to a case involving an immediate post-extraction implant in position 12. Results: With the limitations of a case report, the application of the FR protocol demonstrated stable crestal bone levels at the 1-year follow-up. Additionally, soft tissue volume was maintained at 6 months, reflecting the accuracy of the customized prosthetic components in supporting, guiding, and protecting peri-implant soft tissues. At the 1-year follow-up, an increase in soft tissue volume was observed, likely attributable to tissue maturation and the further customization of the definitive prosthetic elements. Conclusions: The FR technique represents a viable therapeutic alternative that, through its patented, fully customized components, allows for the digital planning of the implant, as well as the customized definitive abutment, coping, provisional, and final prosthetic framework. This facilitates a single-stage surgical and prosthetic approach. By eliminating the need for repeated abutment disconnections, this method supports the long-term stability of both hard and soft peri-implant tissues while also reducing overall treatment time for both clinician and patient. Further studies involving larger patient cohorts are necessary to validate this protocol. Full article
(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
Show Figures

Figure 1

13 pages, 1322 KiB  
Article
Effects of Different Patient and Prosthetic Variables on Marginal Bone Behavior in Dental Implants: A Clinical Retrospective Study
by Sergio Alexandre Gehrke, Antonio Scarano, Felice Lorusso, Thalles Yurgen Balduino and Marco Aurélio Bianchini
Medicina 2025, 61(6), 1041; https://doi.org/10.3390/medicina61061041 - 5 Jun 2025
Viewed by 1032
Abstract
Background and Objectives: This study aimed to evaluate marginal bone level (MBL) changes in implant-supported rehabilitation based on patient demographics, implant location, transmucosal abutment height, and crown emergence profile. Materials and Methods: A total of 50 patients (28 females and 22 males), [...] Read more.
Background and Objectives: This study aimed to evaluate marginal bone level (MBL) changes in implant-supported rehabilitation based on patient demographics, implant location, transmucosal abutment height, and crown emergence profile. Materials and Methods: A total of 50 patients (28 females and 22 males), with 111 implant–abutment (IA) sets, were analyzed. The mean age was 65.2 ± 10.9 years (range: 33–81). Implants were placed in the maxilla (68.5%) and mandible (31.5%), with an average evaluation period of 12.7 ± 4.1 months. MBL changes at mesial (MBLm) and distal (MBLd) sites were recorded and analyzed based on sex, age, implant location, abutment transmucosal height, and crown emergence profile. Statistical comparisons were performed using Bonferroni’s multiple comparison test and one-way ANOVA with Tukey’s post hoc test. Results: MBL changes did not show significant differences based on sex (p > 0.05) or age group (p > 0.05). However, maxillary implants exhibited greater bone loss than mandibular implants, though this difference was not statistically significant. Transmucosal abutment height (TMh) significantly influenced MBL, with taller abutments (TMh3: −1.07 ± 0.93 mm) showing less bone loss than shorter abutments (TMh1: −2.11 ± 1.82 mm) (p < 0.05). Crown emergence profile also affected MBL, particularly in the distal emergence profile, where design 1 exhibited the least bone loss compared to designs 2 and 3 (p = 0.0176). Conclusions: The study findings suggest that transmucosal abutment height and crown emergence profile significantly influence peri-implant bone stability. Transmucosal abutment height (> 2.5 mm) was associated with reduced bone loss. Further research is recommended to evaluate the long-term effects on peri-implant bone maintenance. Full article
(This article belongs to the Section Dentistry and Oral Health)
Show Figures

Figure 1

10 pages, 1975 KiB  
Communication
Influence of Abutment Geometry on Zirconia Crown Retention: An In Vitro Study
by Bayandelger Davaatseren, Jae-Sung Kwon, Sangho Eom and Jae Hoon Lee
Materials 2025, 18(11), 2469; https://doi.org/10.3390/ma18112469 - 24 May 2025
Cited by 1 | Viewed by 677
Abstract
Background/Objectives: This in vitro study investigated the retention of three different geometrical designs of short titanium base (Ti-base) abutments used in implant-supported zirconia crowns. The advent of digital technology has facilitated the integration of Ti-base abutments into implant dentistry by improving time [...] Read more.
Background/Objectives: This in vitro study investigated the retention of three different geometrical designs of short titanium base (Ti-base) abutments used in implant-supported zirconia crowns. The advent of digital technology has facilitated the integration of Ti-base abutments into implant dentistry by improving time efficiency, precision, and patient comfort. Methods: Three types of short Ti-base abutments were evaluated: Geo SRN multibase® (Group A), Herilink® (Group B), and TS Link® (Group C), each with a height of 4 mm and gingival height of 1 mm (n = 20 per group). Zirconia crowns (LUXEN® Smile S2, DentalMax, Republic of Korea) were modified for the testing setup and fabricated using CAD/CAM technology, then bonded to the abutments with RelyX® Luting 2 resin-modified glass ionomer cement. Pull-out tests were conducted at a crosshead speed of 1 mm/min to assess retention. Results: One-way ANOVA and post hoc Tukey tests revealed significant differences in retention values among the different abutment shapes (p < 0.05). The mean retention forces were 194.65 N for Group A, 241.33 N for Group C, and 360.20 N for Group B. Conclusions: The geometrical design of Ti-base short abutments significantly affects the retention of CAD/CAM zirconia crowns, with hexagonal shapes (Group B) demonstrating superior retention. Clinically, selecting an abutment design with enhanced mechanical retention may improve the long-term success of implant-supported restorations. Full article
(This article belongs to the Special Issue Advances in Dental and Restorative Materials)
Show Figures

Figure 1

Back to TopTop