Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (608)

Search Parameters:
Keywords = Vickers micro-hardness

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 1945 KiB  
Article
Effect of Thermal Ageing on Flexural Strength and Microhardness of Novel High-Performance Polymer (Nanoksa G-Plus) in Comparison to a Widely Used Bio-HPP/PEEK
by Ramy Abdallah Abdelrahim, Ahmed Ali Ezzeldine, Mahmoud Abdellah and SaadEldein Sadeq Elghazawi
Dent. J. 2025, 13(8), 370; https://doi.org/10.3390/dj13080370 - 15 Aug 2025
Abstract
Background/Objectives: The dental industry is continuously developing high-performance polymer (HPP) materials with different qualities for denture frameworks. The aim of this in vitro study was to assess how thermal ageing (TA) affects the flexural strength (FS) and microhardness of two different HPP materials: [...] Read more.
Background/Objectives: The dental industry is continuously developing high-performance polymer (HPP) materials with different qualities for denture frameworks. The aim of this in vitro study was to assess how thermal ageing (TA) affects the flexural strength (FS) and microhardness of two different HPP materials: Nanoksa G-plus and Bio-HPP/PEEK. Methods: The TA process was carried out for 5000 cycles at 5 °C and 55 °C in distilled water. To assess FS, a total of 40 bar-shaped specimens measuring 65.0 mm × 10.0 mm × 2.5 mm (20 per group) were obtained; TA and No-TA (NTA) subgroups were prepared for each material group (10 per subgroup); and a three-point bending test was conducted using an Instron universal testing machine. Each specimen that fractured during the FS test was subjected to microhardness measurement using a Vickers hardness tester. The mean FS and microhardness of the TA and NTA specimens were statistically examined using the t-test. Results: Both the TA and NTA Bio-HPP/PEEK specimens exhibited significantly greater (p < 0.0001) microhardness and FS qualities than the Nanoksa G-Plus specimens. The FS and microhardness of the Bio-HPP/PEEK and Nanoksa G-Plus materials significantly decreased (p < 0.05) after TA. Conclusions: The Bio-HPP/PEEK material showed better FS and microhardness properties than the Nanoksa G-Plus material. TA considerably decreased the FS and microhardness of the Bio-HPP/PEEK and Nanoksa G-Plus materials. Full article
Show Figures

Figure 1

14 pages, 3377 KiB  
Article
Mechanical Properties of Dental Enamel in Patients with Genetic Caries Susceptibility
by Firas Haj Obeid, Karolina Jezierska, Danuta Lietz-Kijak, Piotr Skomro, Totka Bakalova, Jacek Gronwald, Piotr Baszuk, Cezary Cybulski, Wojciech Kluźniak, Barbara Gronwald, Magdalena Sroczyk-Jaszczyńska, Alicja Nowicka, Petr Louda and Helena Gronwald
Int. J. Mol. Sci. 2025, 26(16), 7749; https://doi.org/10.3390/ijms26167749 - 11 Aug 2025
Viewed by 453
Abstract
This study evaluated the physicochemical and morphological properties of tooth enamel in patients with caries-predisposing SNPs (rs4694075 in AMBN and rs2337359 in TUFT1 genes), based on the DMFT index. We included 40 of 120 individuals (aged 19–43), collecting stimulated saliva and 58 healthy [...] Read more.
This study evaluated the physicochemical and morphological properties of tooth enamel in patients with caries-predisposing SNPs (rs4694075 in AMBN and rs2337359 in TUFT1 genes), based on the DMFT index. We included 40 of 120 individuals (aged 19–43), collecting stimulated saliva and 58 healthy teeth extracted for orthodontic/surgical reasons. Saliva DNA was genotyped. Enamel properties were assessed using Vickers microhardness, deposition thickness, and calcium content. Genotype and allele frequencies aligned with the literature. The TUFT1C/C genotype subgroup showed a significantly higher DMFT index (p = 0.03) compared to the T/T genotype, while AMBN showed no such correlation. Calcium content, microhardness, and enamel thickness were similar across all polymorphic variants of both genes. A statistically significant correlation (p = 0.003) was found between reduced enamel calcium content and a higher DMFT index. Despite existing literature on the subject, the studied SNPs did not reflect any correlation with morphological or physicochemical changes in enamel. The above results suggest that genetic variability identifies patients classified by dentists as being at higher risk of caries, even though these patients follow a non-cariogenic diet and adhere to a hygiene regime. As no structural or physicochemical changes in the enamel of this group were observed, the potential cause may be disturbances in the remineralisation mechanisms or enamel surface properties that promote biofilm adhesion in polymorphic patients. Intensive tooth calcification control algorithms using LIF and RVG, as well as remineralisation cycles to increase hydroxyapatite saturation with calcium phosphates and bioadhesive fluoride delivery systems for long-term biofilm control, are used to more effectively prevent or slow down the progression of caries. Full article
(This article belongs to the Special Issue Application of Biotechnology to Dental Treatment)
Show Figures

Figure 1

13 pages, 1043 KiB  
Article
Color-Dependent Polymerization: The Impact of Curing Time on the Conversion Degree and Microhardness of Colored Compomers
by Ozgul Carti Dorterler, Fatma Yilmaz and Ozge Tokul Olmez
Polymers 2025, 17(15), 2155; https://doi.org/10.3390/polym17152155 - 6 Aug 2025
Viewed by 232
Abstract
This study investigated the effects of color shade and curing time on the degree of conversion (DC) and microhardness of colored compomers. A total of 162 samples (81 for DC, 81 for microhardness) were prepared, with nine samples per color group (gold, blackberry, [...] Read more.
This study investigated the effects of color shade and curing time on the degree of conversion (DC) and microhardness of colored compomers. A total of 162 samples (81 for DC, 81 for microhardness) were prepared, with nine samples per color group (gold, blackberry, green, pink, orange, lemon, blue, silver) and for the control. Samples were subdivided into three polymerization subgroups (3 s/3200 mW/cm2, 10 s/1000 mW/cm2, 20 s/1000 mW/cm2). The DC was analyzed via fourier transform infrared spectroscopy (FTIR) and microhardness was measured using Vickers testing. Statistical analysis included two-way ANOVA and Spearman correlation (α = 0.05). The colored compomers demonstrated a significantly lower DC compared to the control group (p ≤ 0.001). Among the tested colors, green exhibited the lowest DC (33.3%), while orange showed the highest (51.0%). A significant difference in DC was observed across curing times (p = 0.005), with the 3 s and 20 s groups exhibiting significantly higher conversion rates than the 10 s group. Microhardness values exhibited significant variation depending on the color (p < 0.001). Gold compomers demonstrated the lowest microhardness, whereas silver compomers showed comparable performance with the control group (p = 0.154). A moderate correlation between DC and microhardness was observed overall (ρ = 0.42, p = 0.003). However, the observed relationships were color-dependent: orange displayed a strong positive correlation (ρ = 0.78), whereas pink revealed no meaningful association (ρ = −0.15). Color and curing time critically influence compomer performance. High-intensity short curing is viable for lighter colors, while darker colors require extended curing. Customized protocols are essential to optimize clinical outcomes in pediatric dentistry. Full article
(This article belongs to the Section Polymer Analysis and Characterization)
Show Figures

Graphical abstract

20 pages, 1448 KiB  
Article
In Vitro Evaluation of Chemical and Microhardness Alterations in Human Enamel Induced by Three Commercial In-Office Bleaching Agents
by Berivan Laura Rebeca Buzatu, Atena Galuscan, Ramona Dumitrescu, Roxana Buzatu, Magda Mihaela Luca, Octavia Balean, Gabriela Vlase, Titus Vlase, Iasmina-Mădălina Anghel, Carmen Opris, Bianca Ioana Todor, Mihaela Adina Dumitrache and Daniela Jumanca
Dent. J. 2025, 13(8), 357; https://doi.org/10.3390/dj13080357 - 6 Aug 2025
Viewed by 254
Abstract
Background/Objectives: In-office bleaching commonly employs high concentrations of hydrogen peroxide (HP) or carbamide peroxide (CP), which may compromise enamel integrity. This in vitro paired-design study aimed to compare the chemical and mechanical effects of three commercial bleaching agents—Opalescence Boost (40% HP), Opalescence [...] Read more.
Background/Objectives: In-office bleaching commonly employs high concentrations of hydrogen peroxide (HP) or carbamide peroxide (CP), which may compromise enamel integrity. This in vitro paired-design study aimed to compare the chemical and mechanical effects of three commercial bleaching agents—Opalescence Boost (40% HP), Opalescence Quick (45% CP), and BlancOne Ultra+ (35% HP)—on human enamel. The null hypothesis assumed no significant differences between the control and treated samples. Given the ongoing debate over pH, active ingredients, and enamel impact, comparing whitening systems remains clinically important. Methods: Forty-two extracted teeth were assigned to three experimental groups (n = 14) with matched controls. Each underwent a single bleaching session per manufacturer protocol: Opalescence Boost (≤60 min), Opalescence Quick (15–30 min), and BlancOne Ultra+ (three light-activated cycles of 8–10 min). Enamel chemical changes were analyzed by Fourier transform infrared (FTIR) spectroscopy (phosphate and carbonate bands), and surface hardness by Vickers microhardness testing. Paired t-tests (α = 0.05) assessed statistical significance. Results: FTIR analysis revealed alterations in phosphate and carbonate bands for all agents, most notably for Opalescence Boost and BlancOne Ultra+. Microhardness testing showed significant reductions in enamel hardness for Opalescence Boost (control: 37.21 ± 1.74 Hv; treated: 34.63 ± 1.70 Hv; p = 0.00) and Opalescence Quick (control: 45.82 ± 1.71 Hv; treated: 39.34 ± 1.94 Hv; p < 0.0001), whereas BlancOne Ultra+ showed no significant difference (control: 51.64 ± 1.59 HV; treated: 51.60 ± 2.34 Hv; p = 0.95). Conclusions: HP-based agents, particularly at higher concentrations, caused greater enamel alterations than CP-based products. While clinically relevant, the results should be interpreted cautiously due to in vitro limitations and natural enamel variability. Full article
(This article belongs to the Special Issue Advances in Esthetic Dentistry)
Show Figures

Graphical abstract

9 pages, 1214 KiB  
Article
The Effect of Frankincense and Myrrh on the Sealing Ability and Hardness of Glass Ionomer Cement
by Hala Hanna, Nsar Azeez, Diyar Khalid Bakr and Media Saeed
Ceramics 2025, 8(3), 101; https://doi.org/10.3390/ceramics8030101 - 6 Aug 2025
Viewed by 242
Abstract
Efforts to enhance the mechanical and physicochemical properties of conventional glass ionomer cement (GIC) are ongoing. This study aimed to evaluate the effect of incorporating varying concentrations of frankincense and myrrh liquids into conventional GIC on its microhardness and sealing ability. Frankincense and [...] Read more.
Efforts to enhance the mechanical and physicochemical properties of conventional glass ionomer cement (GIC) are ongoing. This study aimed to evaluate the effect of incorporating varying concentrations of frankincense and myrrh liquids into conventional GIC on its microhardness and sealing ability. Frankincense and myrrh liquids were prepared by dissolving 25 g of each ground resin in 50 mL of distilled water at 60 °C and allowing the solutions to stand for 8 h. Five experimental groups were evaluated: Group A (conventional GIC), Group B (15% frankincense-modified GIC), Group C (25% frankincense-modified GIC), Group D (15% myrrh-modified GIC), and Group E (25% myrrh-modified GIC). Microhardness was evaluated using a Vickers hardness tester, and sealing ability was evaluated via interfacial gap measurements using scanning electron microscopy (SEM). SEM analysis revealed that all modified GIC groups exhibited significantly smaller interfacial gap sizes (Groups B–E: 6.1, 5.22, 5.9, and 5.34 µm, respectively) compared to conventional GIC (Group A: 6.88 µm). However, there were no statistically significant differences in microhardness among the groups (p > 0.5). The incorporation of 15% and 25% concentrations of frankincense or myrrh liquids into conventional GIC significantly improved sealing ability without compromising hardness. Full article
Show Figures

Figure 1

12 pages, 728 KiB  
Article
Comparison of Microhardness and Depth of Cure of Six Bulk-Fill Resin Composites
by Tomislav Skrinjaric, Kristina Gorseta, Jelena Bagaric, Petra Bucevic Sojcic, Jakov Stojanovic and Luc A. M. Marks
J. Compos. Sci. 2025, 9(8), 418; https://doi.org/10.3390/jcs9080418 - 5 Aug 2025
Viewed by 224
Abstract
Background. Physicomechanical properties and clinical service of bulk-fill composites depend on their adequate polymerization and depth of cure. Some manufacturers claim that these composites can be adequately cured when used in bulks exceeding 4 mm. Objective. The aim of this study was to [...] Read more.
Background. Physicomechanical properties and clinical service of bulk-fill composites depend on their adequate polymerization and depth of cure. Some manufacturers claim that these composites can be adequately cured when used in bulks exceeding 4 mm. Objective. The aim of this study was to compare Vickers microhardness (VMH) and depth of cure (DOC) of six contemporary bulk-fill resin composites at depths of 4 mm and 6 mm. Material and methods. Six bulk-fill composites were evaluated in this study: 1. Tetric EvoCeram Bulk (Ivoclar Vivadent, Schaan, Liechtenstein), (TEC); 2. Filtek Bulk Fill Posterior (3M ESPE Dental Products Division, St. Paul, MN, USA), (FBF); 3. Filtek One Bulk Fill (3M ESPE Dental Products Division, St. Paul, MN, USA, (FOB); 4. SonicFill 2 (Kerr, Orange, CA, USA), (SF2); 5. Admira Fusion X-tra (Voco, GmbH, Cuxhaven, Germany), (AFX); 6. GrandioSO X-tra (Voco, GmbH, Cuxhaven, Germany), (GSX). The 18 specimens (3 of each composite) were prepared in split Teflon moulds of 4 mm diameter and 6 mm thickness. All composites were cured in standard mode for 20 s using LED LCU (D-Light Duo, RF-Pharmaceuticals Sarl, Geneva, Switzerland; 1200–1300 mW/cm). The VMH was measured using a digital Micro Hardness Tester Shimadzu (HMV-2T E, Shimadzu Corporation, Kyoto, Japan). A 50 g (0.5 N) load force was applied for 30 s. Each specimen was measured at five places selected by chance at each level (N = 15). The hardness ratio or DOC was calculated for all samples as the ratio of bottom and surface microhardness at levels of 4 and 6 mm. Data were analysed using one-way ANOVA and Tukey’s post hoc test. Results. Significant reduction in VMH was observed for all tested materials when comparing top surface and bottom (p < 0.01). The highest VMH was obtained for GSX and AFX, and the lowest for TEC. The results show that the degree of polymerization was adequate for all tested materials at a depth of 6 mm, since the hardness ratio exceeded 0.80 in all cases. The hardness ratio at 4 mm was high for all tested composites ranging from 0.91 for TEC to 0.98 for GSX. All composites showed adequate DOC at the bottom of the 6 mm bulk samples. However, the hardness ratio was the highest for Admira Fusion X-tra (0.96) and GrandioSO X-tra (0.97). Conclusions. All tested materials showed a significant decrease in microhardness from the top surface to the bottom. The DOC was adequate for all bulk-fill composites at a depth of 6 mm cured under standard mode for 20 s. All bulk-fill resin composites evaluated in this study can be used in bulk, up to 6 mm. Full article
(This article belongs to the Special Issue Innovations in Direct and Indirect Dental Composite Restorations)
Show Figures

Figure 1

17 pages, 2269 KiB  
Article
Photocurable Resin Composites with Silica Micro- and Nano-Fillers for 3D Printing of Dental Restorative Materials
by Pirat Karntiang, Hiroshi Ikeda, Yuki Nagamatsu and Hiroshi Shimizu
J. Compos. Sci. 2025, 9(8), 405; https://doi.org/10.3390/jcs9080405 - 1 Aug 2025
Viewed by 450
Abstract
This study aimed to develop experimental filler-reinforced resin composites for vat-photopolymerization 3D printing and to evaluate the effects of filler addition on their mechanical, physicochemical, and bonding properties for dental restorative applications. Silanized nano- and/or micro-fillers were incorporated into acrylic resin monomers to [...] Read more.
This study aimed to develop experimental filler-reinforced resin composites for vat-photopolymerization 3D printing and to evaluate the effects of filler addition on their mechanical, physicochemical, and bonding properties for dental restorative applications. Silanized nano- and/or micro-fillers were incorporated into acrylic resin monomers to formulate photocurable resins suitable for vat-photopolymerization. The rheological behavior of these liquid-state resins was assessed through viscosity measurements. Printed resin composites were fabricated and characterized for mechanical properties—including flexural strength, flexural modulus, and Vickers hardness—both before and after 8 weeks of water immersion. Physicochemical properties, such as water sorption, water solubility, and degree of conversion, were also evaluated. Additionally, shear bond strength to a resin-based luting agent was measured before and after artificial aging via thermocycling. A commercial dental CAD-CAM resin composite served as a reference material. Filler incorporation significantly improved the mechanical properties of the printed composites. The highest performance was observed in the composite containing 60 wt% micro-fillers, with a flexural strength of 168 ± 10 MPa, flexural modulus of 6.3 ± 0.4 GPa, and Vickers hardness of 63 ± 1 VHN, while the commercial CAD-CAM composite showed values of 152 ± 8 MPa, 7.9 ± 0.3 GPa, and 66 ± 2 VHN, respectively. Filler addition did not adversely affect the degree of conversion, although the relatively low conversion led to the elution of unpolymerized monomers and increased water solubility. The shear bond strength of the optimal printed composite remained stable after aging without silanization, demonstrating superior bonding performance compared with the CAD-CAM composite. These findings suggest that the developed 3D-printed resin composite is a promising candidate for dental restorative materials. Full article
(This article belongs to the Special Issue Innovations in Direct and Indirect Dental Composite Restorations)
Show Figures

Figure 1

21 pages, 2189 KiB  
Article
Surface Modification, Characterization, and Cytotoxicity of Ti-6Al-4V Alloy Enriched by EDM Process
by Bárbara A. B. dos Santos, Elaine C. S. Corrêa, Wellington Lopes, Liszt Y. C. Madruga, Ketul C. Popat, Roberta M. Sabino and Hermes de Souza Costa
Appl. Sci. 2025, 15(15), 8443; https://doi.org/10.3390/app15158443 - 30 Jul 2025
Viewed by 437
Abstract
This study investigates the surface modification of Ti-6Al-4V alloy through the electrical discharge machining (EDM) process to improve its suitability for orthopedic and dental implant applications. The analysis focused on evaluating the morphological, wettability, roughness, hardness, and biocompatibility properties of the modified surfaces. [...] Read more.
This study investigates the surface modification of Ti-6Al-4V alloy through the electrical discharge machining (EDM) process to improve its suitability for orthopedic and dental implant applications. The analysis focused on evaluating the morphological, wettability, roughness, hardness, and biocompatibility properties of the modified surfaces. Samples were subjected to different dielectric fluids and polarities during EDM. Subsequently, optical microscopy, roughness measurements, Vickers microhardness, contact angle tests, and in vitro cytotoxicity assays were performed. The results demonstrated that EDM processing led to the formation of distinct layers on the sample surfaces, with surface roughness increasing under negative polarity by up to ~304% in Ra and 305% in Rz. Additionally, wettability measurements indicated that the modified surfaces presented a lower water contact angle, which suggests enhanced hydrophilicity. Moreover, the modified samples showed a significant increase in Vickers microhardness, with the highest value reaching 1520 HV in the recast layer, indicating improvements in the mechanical properties. According to ISO 10993-5, all treated samples were classified as non-cytotoxic, presenting RGR values above 75%, similar to the untreated Ti-6Al-4V alloy. Therefore, it is concluded that surface modification through the EDM process has the potential to enhance the properties and safety of biomedical implants made with this alloy. Full article
(This article belongs to the Special Issue Titanium and Its Compounds: Properties and Innovative Applications)
Show Figures

Figure 1

21 pages, 8317 KiB  
Article
Mechanical Properties and Ballistic Performance for Different Coatings on HARDOX 450 Steel for Defense Applications
by Cosmin Nicolescu, Tudor Viorel Tiganescu, Aurora Antoniac, Ovidiu Iorga, Brandusa Ghiban, Alexandru Pascu, Alexandru Streza and Iulian Antoniac
Crystals 2025, 15(8), 687; https://doi.org/10.3390/cryst15080687 - 29 Jul 2025
Viewed by 428
Abstract
The aim of the current study is to investigate the mechanical properties and ballistic performance of HARDOX 450 steel for defense applications in different conditions: uncoated, alumina-coated, and LINE X polyurea-coated. Tensile tests and Vickers microhardness measurements were conducted, along with fracture surface [...] Read more.
The aim of the current study is to investigate the mechanical properties and ballistic performance of HARDOX 450 steel for defense applications in different conditions: uncoated, alumina-coated, and LINE X polyurea-coated. Tensile tests and Vickers microhardness measurements were conducted, along with fracture surface analysis using stereomicroscopy, scanning electron microscopy, and computed tomography. Experimental results showed that uncoated HARDOX 450 steel exhibited the highest strength and hardness, with ductile fracture features. Polyurea-coated HARDOX 450 steel samples retained good mechanical properties and demonstrated effective ballistic protection, including the containment of fragments. In contrast, alumina-coated HARDOX 450 steel samples exhibited reduced strength and ballistic resistance, attributed to the microstructural changes in HARDOX 450 steel caused by the high-temperature deposition process of alumina. Numerical simulations performed with the 5.56 × 45 mm bullet used in the simulation, along with its ballistic impact interaction with the Hardox 450 target model, aligned well with experimental ballistic impact results for all the samples. Overall, LINE X polyurea coating on HARDOX 450 steel proved to be the more suitable coating for applications requiring a balance of mechanical strength and ballistic impact resistance. Full article
Show Figures

Figure 1

14 pages, 2733 KiB  
Article
Study on Microstructure and Wear Resistance of Multi-Layer Laser Cladding Fe901 Coating on 65 Mn Steel
by Yuzhen Yu, Weikang Ding, Xi Wang, Donglu Mo and Fan Chen
Materials 2025, 18(15), 3505; https://doi.org/10.3390/ma18153505 - 26 Jul 2025
Viewed by 298
Abstract
65 Mn is a high-quality carbon structural steel that exhibits excellent mechanical properties and machinability. It finds broad applications in machinery manufacturing, agricultural tools, and mining equipment, and is commonly used for producing mechanical parts, springs, and cutting tools. Fe901 is an iron-based [...] Read more.
65 Mn is a high-quality carbon structural steel that exhibits excellent mechanical properties and machinability. It finds broad applications in machinery manufacturing, agricultural tools, and mining equipment, and is commonly used for producing mechanical parts, springs, and cutting tools. Fe901 is an iron-based alloy that exhibits excellent hardness, structural stability, and wear resistance. It is widely used in surface engineering applications, especially laser cladding, due to its ability to form dense and crack-free metallurgical coatings. To enhance the surface hardness and wear resistance of 65 Mn steel, this study employs a laser melting process to deposit a multi-layer Fe901 alloy coating. The phase composition, microstructure, microhardness, and wear resistance of the coatings are investigated using X-ray diffraction (XRD), optical microscopy, scanning electron microscopy (SEM), Vickers hardness testing, and friction-wear testing. The results show that the coatings are dense and uniform, without visible defects. The main phases in the coating include solid solution, carbides, and α-phase. The microstructure comprises dendritic, columnar, and equiaxed crystals. The microhardness of the cladding layer increases significantly, with the multilayer coating reaching 3.59 times the hardness of the 65 Mn substrate. The coatings exhibit stable and relatively low friction coefficients ranging from 0.38 to 0.58. Under identical testing conditions, the wear resistance of the coating surpasses that of the substrate, and the multilayer coating shows better wear performance than the single-layer one. Full article
(This article belongs to the Section Advanced Composites)
Show Figures

Figure 1

29 pages, 6770 KiB  
Article
Machine Learning-Driven Design and Optimization of Multi-Metal Nitride Hard Coatings via Multi-Arc Ion Plating Using Genetic Algorithm and Support Vector Regression
by Yu Gu, Jiayue Wang, Jun Zhang, Yu Zhang, Bushi Dai, Yu Li, Guangchao Liu, Li Bao and Rihuan Lu
Materials 2025, 18(15), 3478; https://doi.org/10.3390/ma18153478 - 24 Jul 2025
Viewed by 304
Abstract
The goal of this study is to develop an efficient machine learning framework for designing high-hardness multi-metal nitride coatings, overcoming the limitations of traditional trial-and-error methods. The development of multicomponent metal nitride hard coatings via multi-arc ion plating remains a significant challenge due [...] Read more.
The goal of this study is to develop an efficient machine learning framework for designing high-hardness multi-metal nitride coatings, overcoming the limitations of traditional trial-and-error methods. The development of multicomponent metal nitride hard coatings via multi-arc ion plating remains a significant challenge due to the vast compositional search space. Although theoretical studies in macroscopic, mesoscopic, and microscopic domains exist, these often focus on idealized models and lack effective coupling across scales, leading to time-consuming and labor-intensive traditional methods. With advancements in materials genomics and data mining, machine learning has become a powerful tool in material discovery. In this work, we construct a compositional search space for multicomponent nitrides based on electronic configuration, valence electron count, electronegativity, and oxidation states of metal elements in unary nitrides. The search space is further constrained by FCC crystal structure and hardness theory. By incorporating a feature library with micro-, meso-, and macro-structural characteristics and using clustering analysis with theoretical intermediate variables, the model enriches dataset information and enhances predictive accuracy by reducing experimental errors. This model is successfully applied to design multicomponent metal nitride coatings using a literature-derived database of 233 entries. Experimental validation confirms the model’s predictions, and clustering is used to minimize experimental and data errors, yielding a strong agreement between predicted optimal molar ratios of metal elements and nitrogen and measured hardness performance. Of the 100 Vickers hardness (HV) predictions made by the model using input features like molar ratios of metal elements (e.g., Ti, Al, Cr, Zr) and atomic size mismatch, 82 exceeded the dataset’s maximum hardness, with the best sample achieving a prediction accuracy of 91.6% validated against experimental measurements. This approach offers a robust strategy for designing high-performance coatings with optimized hardness. Full article
(This article belongs to the Special Issue Advances in Computation and Modeling of Materials Mechanics)
Show Figures

Figure 1

17 pages, 7068 KiB  
Article
Effect of Ni-Based Buttering on the Microstructure and Mechanical Properties of a Bimetallic API 5L X-52/AISI 316L-Si Welded Joint
by Luis Ángel Lázaro-Lobato, Gildardo Gutiérrez-Vargas, Francisco Fernando Curiel-López, Víctor Hugo López-Morelos, María del Carmen Ramírez-López, Julio Cesar Verduzco-Juárez and José Jaime Taha-Tijerina
Metals 2025, 15(8), 824; https://doi.org/10.3390/met15080824 - 23 Jul 2025
Viewed by 353
Abstract
The microstructure and mechanical properties of welded joints of API 5L X-52 steel plates cladded with AISI 316L-Si austenitic stainless steel were evaluated. The gas metal arc welding process with pulsed arc (GMAW-P) and controlled arc oscillation were used to join the bimetallic [...] Read more.
The microstructure and mechanical properties of welded joints of API 5L X-52 steel plates cladded with AISI 316L-Si austenitic stainless steel were evaluated. The gas metal arc welding process with pulsed arc (GMAW-P) and controlled arc oscillation were used to join the bimetallic plates. After the root welding pass, buttering with an ERNiCrMo-3 filler wire was performed and multi-pass welding followed using an ER70S-6 electrode. The results obtained by optical and scanning electron microscopy indicated that the shielding atmosphere, welding parameters, and electric arc oscillation enabled good arc stability and proper molten metal transfer from the filler wire to the sidewalls of the joint during welding. Vickers microhardness (HV) and tensile tests were performed for correlating microstructural and mechanical properties. The mixture of ERNiCrMo-3 and ER70S-6 filler materials presented fine interlocked grains with a honeycomb network shape of the Ni–Fe mixture with Ni-rich grain boundaries and a cellular-dendritic and equiaxed solidification. Variation of microhardness at the weld metal (WM) in the middle zone of the bimetallic welded joints (BWJ) is associated with the manipulation of the welding parameters, promoting precipitation of carbides in the austenitic matrix and formation of martensite during solidification of the weld pool and cooling of the WM. The BWJ exhibited a mechanical strength of 380 and 520 MPa for the yield stress and ultimate tensile strength, respectively. These values are close to those of the as-received API 5L X-52 steel. Full article
Show Figures

Figure 1

15 pages, 3585 KiB  
Article
Surface Hardness of Polished Dental Zirconia: Influence of Polishing and Yttria Content on Morphology, Phase Composition, and Microhardness
by Andrea Labetić, Teodoro Klaser, Željko Skoko, Marko Jakovac and Mark Žic
Materials 2025, 18(14), 3380; https://doi.org/10.3390/ma18143380 - 18 Jul 2025
Viewed by 322
Abstract
This study examined the relationship between microhardness, morphology, and phase composition of dental yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which directly impact their long-term clinical performance and durability. The primary objective was to investigate the effects of yttria content and polishing on the surface [...] Read more.
This study examined the relationship between microhardness, morphology, and phase composition of dental yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which directly impact their long-term clinical performance and durability. The primary objective was to investigate the effects of yttria content and polishing on the surface properties and hardness of these materials. Samples from ZirCAD Prime, Cercon ht ML, ZIRCONIA YML, and ZirCAD LT were analyzed using Vickers hardness testing, Powder X-ray Diffraction (PXRD), and Scanning Electron Microscopy (SEM). SEM analysis revealed a gradual increase in grain size and porosity with higher yttria content in unpolished samples. Polishing resulted in a relatively uniform surface morphology with observable striations across all samples, subsequently leading to similar Vickers hardness values for all polished samples. PXRD and SEM analyses identified that these similar hardness values were likely due to the predominant monoclinic phase on the surface, induced by polishing. These findings underscore the significant influence of yttria content and polishing on Y-TZP microstructure and surface hardness, highlighting their critical role in the long-term success and clinical applicability of dental restorations. Full article
Show Figures

Figure 1

15 pages, 5452 KiB  
Article
Roughness and Gloss of 3D-Printed Crowns Following Polishing or Varnish Application
by Silvia Rojas-Rueda, Tariq Aziz Alsahafi, Mohammed Hammamy, Neeraj Surathu, Nitish Surathu, Nathaniel C. Lawson and Taiseer A. Sulaiman
Materials 2025, 18(14), 3308; https://doi.org/10.3390/ma18143308 - 14 Jul 2025
Viewed by 384
Abstract
The aim of this study was to evaluate and compare the surface roughness and gloss—both initially and after simulated toothbrushing—of three 3D-printed crown materials subjected to different surface treatments: varnishing, polishing with diamond-impregnated rubber polishers, and polishing with a bristle brush and paste. [...] Read more.
The aim of this study was to evaluate and compare the surface roughness and gloss—both initially and after simulated toothbrushing—of three 3D-printed crown materials subjected to different surface treatments: varnishing, polishing with diamond-impregnated rubber polishers, and polishing with a bristle brush and paste. Disc-shaped specimens (n = 90) were 3D-printed using three commercially available crown resins (Rodin Sculpture, VarseoSmile TriniQ, and OnX Tough 2) and post-processed per manufacturers’ instructions. Specimens were divided into three surface treatment groups: application of a light-cured varnish, polishing with a two-step diamond-impregnated rubber polisher, or polishing with a bristle brush and abrasive paste. Surface roughness and gloss were measured after treatment and again following 20,000 cycles of simulated toothbrushing. Additional specimens were prepared for Vickers microhardness testing and determination of filler weight percentage (wt%). Statistical comparisons were performed using two-way ANOVA with significance set at p < 0.05. Results: The varnish provided the statistically lowest roughness of all surface treatments for all materials. The bristle brush and abrasive paste polishing protocol produced the greatest gloss for the softest material (VarseoSmile TriniQ) and lowest gloss for the hardest material (Rodin Sculpture), whereas the two-step diamond-impregnated rubber polisher produced an equivalent gloss on all materials. Following toothbrushing, roughness was minimally affected; however, gloss was considerably reduced. Conclusions: All tested polishing and varnishing methods achieved clinically acceptable surface roughness (Ra < 0.2 µm) that persisted after simulated toothbrushing. Notably, the two-step diamond-impregnated rubber polisher produced consistent gloss across all materials, while the bristle brush and abrasive paste polishing protocol performed better on softer materials, and varnish application resulted in equal or superior gloss and roughness retention compared to polishing. Full article
(This article belongs to the Special Issue Innovations in Digital Dentistry: Novel Materials and Technologies)
Show Figures

Figure 1

12 pages, 4872 KiB  
Article
Study of the Influence of Gas Tungsten Arc (GTA) Welding on the Microstructure and Properties of Mg–Al–RE-Type Magnesium Alloys
by Katarzyna N. Braszczyńska-Malik
Materials 2025, 18(14), 3277; https://doi.org/10.3390/ma18143277 - 11 Jul 2025
Viewed by 395
Abstract
The effects of the gas tungsten arc (GTA) welding process on the microstructure and microhardness of two Mg-5Al-3RE and Mg-5Al-5RE experimental alloys (RE—rare earth elements) are presented. Both alloys were gravity-cast in a steel mould and GTA-welded in the same conditions. Analyses of [...] Read more.
The effects of the gas tungsten arc (GTA) welding process on the microstructure and microhardness of two Mg-5Al-3RE and Mg-5Al-5RE experimental alloys (RE—rare earth elements) are presented. Both alloys were gravity-cast in a steel mould and GTA-welded in the same conditions. Analyses of the alloys’ microstructure were carried out by scanning electron microscopy (SEM+EDX) as well as X-ray diffraction (XRD). In as-cast conditions; both alloys were mainly composed of α-Mg; Al11RE3; and Al10RE2Mn7 intermetallic phases. Additionally; α+γ eutectic (where γ is Al12Mg17) in the Mg-5Al-3RE alloy and an Al2RE phase in the Mg-5Al-5RE material were revealed. The same phase composition was revealed for both alloys after the GTA welding process. The results of the dendrite arm size (DAS) and Vickers microhardness measurements were also described. Both welded materials exhibited an intensive size reduction of the structural constituents after GTA welding. About 75% smaller values of the dendrite arm spacing were revealed in the fusion zones of the investigated materials than in the as-cast conditions. The GTA welding process also influenced the microhardness of the experimental alloys and increased them by about 21% compared to the base metal; which was the consequence of the refinement of the structural constituents. Full article
(This article belongs to the Collection Alloy and Process Development of Light Metals)
Show Figures

Figure 1

Back to TopTop