Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (38)

Search Parameters:
Keywords = HVDC power supplies

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
32 pages, 3046 KB  
Article
Hybrid Flexible HVDC System and Its Control Strategy for Isolated Renewable Energy External Delivery
by Lijian Xin, Huadong Xing, Teng Mu, Huiqiang Liu, Guihong Yan, Tan’nan Xiao, Yi Su, Bin Cao and Ruming Feng
Energies 2026, 19(17), 4008; https://doi.org/10.3390/en19174008 - 26 Aug 2026
Abstract
High-capacity long-distance HVDC is indispensable for the centralized integration of deep-sea offshore wind farms and sandy-region renewable energy bases. Hybrid flexible HVDC, which adopts voltage-source converters at the sending end and current-source converters at the receiving end, meets the technical needs and potentially [...] Read more.
High-capacity long-distance HVDC is indispensable for the centralized integration of deep-sea offshore wind farms and sandy-region renewable energy bases. Hybrid flexible HVDC, which adopts voltage-source converters at the sending end and current-source converters at the receiving end, meets the technical needs and potentially offers better economic efficiency in terms of converter station capital cost. However, technical challenges remain, including passive sending-end charging and start-up, joint grid formation of multiple converters, commutation failure immunity at the receiving end, and minimum continuous current maintenance. This paper proposes a hybrid flexible HVDC system scheme along with its control strategy. The scheme employs modular multilevel converters (MMCs) at the sending end and hybrid commutated converters (HCCs) at the receiving end, and a small-capacity uncontrolled diode rectifier (UDR) is configured in parallel with the HCCs. Operating characteristics of the three types of converters are analyzed, and the overall system operating strategy is presented. Electromagnetic transient simulation results show that the UDR provides a system charging circuit and can automatically supply continuous current when renewable generation power fluctuates; for bipolar HVDC or hierarchical HVDC, virtual synchronous generator control of the MMCs enables the joint grid formation and realizes the power balance between multiple converters; for faults in the receiving grid, the HCCs are able to actively turn off the valves at risk of commutation failure, ensuring a smooth ride-through. Full article
23 pages, 16802 KB  
Article
Design and Implementation of a High-Power-Density DC Power Supply Based on a Novel Integration of Z-Source and Isolated Full-Bridge DC–DC Converter Topologies
by Mehmet Akif Ozdemir, Ali Shan, Emrullah Aydin, Bulent Dag, Bunyamin Tamyurek and Mehmet Timur Aydemir
Energies 2026, 19(11), 2494; https://doi.org/10.3390/en19112494 - 22 May 2026
Viewed by 435
Abstract
High-voltage DC (HVDC) power supplies are essential for several advanced applications, including medical imaging, aerospace systems, and additive manufacturing. Traditional HVDC supplies often suffer from performance limitations due to high transformer turn ratios, which increased stray capacitance and degraded inverter performance. This paper [...] Read more.
High-voltage DC (HVDC) power supplies are essential for several advanced applications, including medical imaging, aerospace systems, and additive manufacturing. Traditional HVDC supplies often suffer from performance limitations due to high transformer turn ratios, which increased stray capacitance and degraded inverter performance. This paper proposes a novel two-stage HVDC power supply architecture that addresses these challenges by combining a Z-source converter with a full-bridge inverter, both enabled by high-performance Silicon Carbide (SiC) devices. The first stage boosts the rectified line voltage to 2 kV using a Z-source topology and inverts it at high frequency, while the second stage employs a high-voltage, high-frequency (HVHF) transformer and a voltage doubler to achieve a regulated 10 kV DC output. Simulation results using PLECS and experimental validation demonstrate the effectiveness of the proposed design in minimizing the reflected capacitance, enabling constant-frequency operation at the boundary of continuous conduction mode for improved efficiency, and providing high power density and compactness. This approach offers a promising solution for high-efficiency, high-voltage applications. Full article
Show Figures

Figure 1

26 pages, 6592 KB  
Article
A Method for Formulating Delivery Curves of Clean Energy Bases Considering Load Demand of Receiving Provinces
by Xu Han, Jiayan Zhang, Xiao Qin, Jie Gao, Yue Zhao, Zenghai Zhao and Chuntian Cheng
Energies 2026, 19(10), 2445; https://doi.org/10.3390/en19102445 - 19 May 2026
Cited by 1 | Viewed by 408
Abstract
Against the backdrop of China’s dual carbon goals, cross-regional low-carbon power transmission from large-scale clean energy bases is a pivotal direction for energy transition. Formulating their power delivery curves requires precise alignment with the load demand characteristics of receiving provinces and the coordinated [...] Read more.
Against the backdrop of China’s dual carbon goals, cross-regional low-carbon power transmission from large-scale clean energy bases is a pivotal direction for energy transition. Formulating their power delivery curves requires precise alignment with the load demand characteristics of receiving provinces and the coordinated operation of hydropower, wind power, photovoltaic (PV) power, and pumped-storage hydropower (PSH). To address the limitations of existing methods, such as the lack of linearized modeling for core operational constraints, low solution efficiency and inadequate integration of multi-energy coupling constraints, this paper proposes a tailored linearized optimization modeling approach. By adopting auxiliary variables, binary variables and the Big M method, core constraints including PSH pumping power supply, stepwise power delivery and multi-energy coordinated operation are linearized. A monthly rolling linear optimization model is constructed with triple objectives: minimizing the renewable curtailment rate and the absolute error between delivery and load curves, and maximizing delivered electricity volume. Multi-objective coordinated optimization is realized via the linear weighted summation method, and the model is solved with the Gurobi solver. Case validation on an integrated hydro–wind–solar clean energy base in Southwest China and its corresponding receiving provincial power grid shows that the proposed method effectively improves the curve matching degree, controls the wind–PV curtailment rate within around 12% (engineering tolerance), and strictly meets engineering safety constraints such as PSH operation and HVDC transmission requirements. Comprehensive optimization of the three objectives is achieved when the weight coefficients for curtailment rate, load matching error and delivered electricity volume are set to 0.3–0.8, 0.1–0.2 and 0.1–0.6, respectively. This method resolves the problems of traditional nonlinear models being disconnected from engineering practice and low solution efficiency, providing a reliable technical reference for the refined dispatching of cross-regional power transmission and scientific formulation of power delivery curves for clean energy bases. Full article
Show Figures

Figure 1

14 pages, 29597 KB  
Article
Backstepping Super-Twisting Sliding Mode Control for MMC-HVDC in Passive Networks
by Zerong Wang, Xinhong Wu, Hao Dong, Hao Huang and Yongxi Zhao
Energies 2026, 19(9), 2246; https://doi.org/10.3390/en19092246 - 6 May 2026
Viewed by 391
Abstract
Due to their superior harmonic profiles and minimal switching energy losses, modular multilevel converters (MMCs) have emerged as the primary topology for high voltage direct current (HVDC) applications. However, traditional Proportional–Integral (PI) control exhibits inferior dynamic performance using MMC-HVDC supplying power in the [...] Read more.
Due to their superior harmonic profiles and minimal switching energy losses, modular multilevel converters (MMCs) have emerged as the primary topology for high voltage direct current (HVDC) applications. However, traditional Proportional–Integral (PI) control exhibits inferior dynamic performance using MMC-HVDC supplying power in the passive networks. This study proposes a backstepping super-twisting sliding mode control strategy, which significantly improves the dynamic performance of the MMC-HVDC system and mitigates fluctuations in the DC side voltage. First, a mathematical model is established based on the topology of the modular multilevel HVDC transmission system. Then, utilizing the backstepping method, a virtual control law for the current inner loop is designed according to the mathematical model. Subsequently, the super-twisting sliding mode algorithm is introduced based on the backstepping method to form the backstepping super-twisting sliding mode control law. Finally, a comprehensive model is established within the Matlab/Simulink environment, and extensive simulation studies are carried out to evaluate the effectiveness the effectiveness and advantages of the proposed backstepping super-twisting sliding mode control under stable operation, grid voltage sag, and single-phase grounding fault conditions. Comparative evaluations verify that the introduced strategy effectively lowers the total harmonic distortion (THD) of the current and suppresses DC voltage ripples. Moreover, compared to the conventional PI method, the new approach provides enhanced transient robustness with noticeably reduced overshoot with considerably lower overshoot compared to traditional PI control, thereby providing a highly reliable and stable solution for MMC-HVDC systems supplying passive networks. Full article
(This article belongs to the Special Issue Modular Multilevel Converters: Technologies, Control and Applications)
Show Figures

Figure 1

21 pages, 3896 KB  
Article
Investigating the Participation of Embedded VSC-HVDC Systems in Frequency Regulation During Post-Splitting Events via a Coordinated Supplementary Control Layer
by Mohammad Qawaqneh, Gaetano Zizzo, Antony Vasile, Liliana Mineo, Angelo L’Abbate and Lorenzo Carmine Vitulano
Energies 2026, 19(9), 2034; https://doi.org/10.3390/en19092034 - 23 Apr 2026
Viewed by 625
Abstract
Synchronous Alternating Current (AC) power systems are increasingly supported by embedded High-Voltage Direct Current (HVDC) links to enhance operational flexibility and ensure security of supply. However, the loss of High-Voltage Alternating Current (HVAC) interconnections in these synchronous areas may lead to transmission network [...] Read more.
Synchronous Alternating Current (AC) power systems are increasingly supported by embedded High-Voltage Direct Current (HVDC) links to enhance operational flexibility and ensure security of supply. However, the loss of High-Voltage Alternating Current (HVAC) interconnections in these synchronous areas may lead to transmission network splitting, posing serious challenges to frequency stability due to the reduction in overall system inertia and stiffness. In this paper, a supplementary control layer is proposed to enable embedded HVDC systems, particularly those based on modern Voltage Source Converters (VSCs), to support frequency stability under post-splitting conditions. The proposed control strategy combines Angle-Difference Control (ADC), Frequency-Difference Control (FDC), and feedforward action, enabling fast and coordinated active-power modulation. A single-bus, dynamic multi-area Load Frequency Control (LFC) model is developed, combining the regulation of thermal units, Renewable Energy Sources’ (RESs’) Fast Frequency Response (FFR) with Synthetic Inertia (SI), and VSC-HVDC modulation. The effectiveness of the proposed control layer is demonstrated by applying it to the East Tyrrhenian Link (ETL), an embedded VSC-HVDC interconnection connecting Sicily with the mainland of Italy, under a post-splitting low-inertia condition in which Sicily operates as an islanded synchronous system, i.e., after losing synchronism with the mainland of Italy, in a 2030 scenario condition. The simulation results demonstrate that the proposed controller enables embedded VSC-HVDC systems to actively participate in post-splitting frequency containment and damping, as well as coordinated active power reallocation, thereby enhancing overall system stability and resilience. Full article
Show Figures

Figure 1

24 pages, 4083 KB  
Article
Voltage Adaptability of Hierarchical Optimization for Photovoltaic Inverter Control Parameters in AC/DC Hybrid Receiving-End Power Grids
by Ran Sun, Jianbo Wang, Feng Yao, Zhaohui Cui, Xiaomeng Li, Hao Zhang, Jiahao Wang and Lixia Sun
Processes 2026, 14(2), 350; https://doi.org/10.3390/pr14020350 - 19 Jan 2026
Viewed by 569
Abstract
The high rate of photovoltaic integration poses significant challenges in terms of violations of voltage limits in power grids. Additionally, the operational behavior of PV systems under fault conditions requires thorough investigation in receiving-end grids. This paper analyzes the dynamic coupling characteristics between [...] Read more.
The high rate of photovoltaic integration poses significant challenges in terms of violations of voltage limits in power grids. Additionally, the operational behavior of PV systems under fault conditions requires thorough investigation in receiving-end grids. This paper analyzes the dynamic coupling characteristics between reactive power and transient voltage in a receiving-end grid with high PV penetration and multiple HVDC infeeds, considering typical AC and DC fault scenarios. Voltage adaptability issues in PV generation systems are also examined. Through an enhanced sensitivity analysis method, the suppression capabilities of transient voltage peaks are quantified in the control parameters of low-voltage ride-through (LVRT) and high-voltage ride-through (HVRT) photovoltaic inverters. On this basis, a hierarchical optimization strategy for PV inverter control parameters is proposed to mitigate post-fault transient voltage peaks and improve the transient voltage response both during and after faults. The feasibility of the proposed method has been verified through simulation on a revised 10-generator 39-bus power system. Following optimization, the transient voltage peak is reduced from 1.263 to 1.098. This validation offers support for the reliable grid connection of the Henan Power Grid. In the events of the N-2 fault at 500 kV and Tian-zhong HVDC monopolar block fault, the post-fault voltage at each node remains below 1.1 p.u. This serves as evidence of a significant enhancement in transient voltage stability within the Henan Power Grid, demonstrating effective improvements in power supply reliability and operational performance. Full article
Show Figures

Figure 1

23 pages, 7258 KB  
Article
Optimal Grid-Forming Strategy for a Remote Hydrogen Production System Supplied by Wind and Solar Power Through MMC-HVDC Link
by Wujie Chao, Junwei Huang, Zhibo Zhang, Changgeng Tian, Liyu Dai, Jinke Wang and Xinyi Lin
Electronics 2025, 14(24), 4824; https://doi.org/10.3390/electronics14244824 - 8 Dec 2025
Cited by 1 | Viewed by 956
Abstract
Large-scale renewable power supply system design for remote hydrogen production is a challenging task due to the 100% power electronics sending-end subsystem. The proper grid-forming strategy for a sending-end system to achieve large-scale remote hydrogen production still remains a research gap. This study [...] Read more.
Large-scale renewable power supply system design for remote hydrogen production is a challenging task due to the 100% power electronics sending-end subsystem. The proper grid-forming strategy for a sending-end system to achieve large-scale remote hydrogen production still remains a research gap. This study first designs two grid-forming strategies for the concerned renewable power supply system, with one being based on virtual synchronous generator (VSG) and another one being based on V/f control. Then, the impedance analysis is carried out for ensuring the small-signal stable operation of the sending-end system including wind power plant and PV plant. Numerical simulation results implemented on PSCAD verify that the VSG-based grid-forming strategy configured on the sending-end modular multilevel converter (MMC) station of the MMC-based high-voltage direct-current (HVDC) link has a larger transient stability margin. Hence, the MMC-HVDC-based grid-forming strategy is a better choice for the power supply of large-scale remote hydrogen production. The enhanced stability margin ensures more robust operation under disturbances, which is critical for maintaining continuous power supply to large-scale electrolyzers. Full article
Show Figures

Figure 1

19 pages, 2960 KB  
Article
An Optimal Capacity Configuration Method for a Renewable Energy Integration-Transmission System Considering Economics and Reliability
by Zhicheng Sha, Canyu Cui, Zhuodi Wang, Fei Yu, Shujian Yin, Zhishuo Yang, Chuanyu Cao, Xiaohan Huang and Zhijie Liu
Symmetry 2025, 17(11), 1880; https://doi.org/10.3390/sym17111880 - 5 Nov 2025
Cited by 3 | Viewed by 1017
Abstract
Integrated Energy Transmission Systems (IETSs) are essential to bridge the geographical gap between where energy is produced and where it is needed, transporting power from resource-rich regions to distant load centers. The fundamental challenge is to resolve the inherent asymmetry between an intermittent [...] Read more.
Integrated Energy Transmission Systems (IETSs) are essential to bridge the geographical gap between where energy is produced and where it is needed, transporting power from resource-rich regions to distant load centers. The fundamental challenge is to resolve the inherent asymmetry between an intermittent power supply and distant load demand. Conventional approaches, focusing only on capacity, fail to address this issue while achieving an effective economic and reliable balance. To address the concerns above, a bilevel optimization framework is proposed to optimize the capacity configuration of IETSs, including wind power, photovoltaic (PV), thermal power, and pumped storage. The optimal capacity of wind and PV is determined by the upper-level model to minimize electricity price, whereas the lower-level model optimizes the system’s operational dispatch for given configuration to minimize operational expenses. A detailed IETS model is also developed to accurately capture the operational characteristics of diverse power sources. Furthermore, the proposed model integrates carbon emission costs and High-Voltage Direct Current (HVDC) utilization constraints, thereby allowing for a comprehensive assessment of their economic efficiency and reliability for capacity configuration. Case studies are conducted to verify the proposed method. The results show that the capacities of wind and PV are optimized, and the electricity costs of IETSs are minimized while satisfying reliability constraints. Full article
Show Figures

Figure 1

35 pages, 1429 KB  
Systematic Review
Transmission-Targeted Demand-Side Response for Congestion Relief: A Systematic Review
by Piotr Sidor and Sylwester Robak
Energies 2025, 18(21), 5705; https://doi.org/10.3390/en18215705 - 30 Oct 2025
Cited by 2 | Viewed by 2891
Abstract
Variable renewable energy sources and cross-zonal trades stress transmission grids, pushing them toward thermal limits. This systematic review, reported in accordance with PRISMA 2020, examines how demand-side response (DSR) can provide relief at the transmission scale. We screened peer-reviewed literature and operator documentation, [...] Read more.
Variable renewable energy sources and cross-zonal trades stress transmission grids, pushing them toward thermal limits. This systematic review, reported in accordance with PRISMA 2020, examines how demand-side response (DSR) can provide relief at the transmission scale. We screened peer-reviewed literature and operator documentation, from 2010 to 2025, indexed in Web of Science, Scopus, and IEEE Xplore; organized remedial actions across supply, network, and demand/storage levers; and categorized operational attributes (time to effect, spatial targeting, activation lead times, telemetry, and measurement and verification). Few reviewed sources explicitly link DSR to transmission congestion relief, highlighting the gap between its mature use in frequency and adequacy services and its still-limited, location-specific application on the grid. We identify feasibility conditions, including assets downstream of the binding interface, minute-scale activation, and feeder-grade baselines with rebound accounting. This implies the following design requirements: TSO–DSO eligibility registries and conflict resolution, portfolio mapping to power-flow sensitivities, and co-optimization with redispatch, HVDC, topology control, and storage within a security-constrained optimal-power-flow framework. No full-text risk-of-bias assessment or meta-analysis was undertaken; the review used English-only title/abstract screening. Registration: none. Funding: none. Full article
(This article belongs to the Section F1: Electrical Power System)
Show Figures

Figure 1

21 pages, 3283 KB  
Article
Embedded HVDC System Planning Methods for Typical Scenarios in Regional Power Grids
by Qucheng Xie, Ying Huang, Hui Cai, Guoteng Wang, Fei Dou and Wentao Sun
Electronics 2025, 14(16), 3292; https://doi.org/10.3390/electronics14163292 - 19 Aug 2025
Cited by 1 | Viewed by 1576
Abstract
The embedded HVDC system is a form of DC power system that enhances regional power grids. This paper innovatively categorizes the typical application scenarios of embedded HVDC into three types: transmission section reinforcement, new energy delivery, and power supply zone interconnection. It further [...] Read more.
The embedded HVDC system is a form of DC power system that enhances regional power grids. This paper innovatively categorizes the typical application scenarios of embedded HVDC into three types: transmission section reinforcement, new energy delivery, and power supply zone interconnection. It further pioneers an exploration of the planning approach by breaking it down into three key aspects: identifying embedded HVDC construction demands, determining capacity, and selecting embedding points. For each scenario, specific planning steps are proposed to advance the practical application in reginal power grids. Finally, the planning methods are applied and verified through a case study in Jiangsu, China. Viable embedded HVDC schemes are obtained and compared with the AC approaches. Full article
Show Figures

Figure 1

20 pages, 1303 KB  
Article
Evaluation System of AC/DC Strong–Weak Balance Relationship and Stability Enhancement Strategy for the Receiving-End Power Grid
by Hui Cai, Mingxin Yan, Xingning Han, Guoteng Wang, Quanquan Wang and Ying Huang
Energies 2025, 18(16), 4216; https://doi.org/10.3390/en18164216 - 8 Aug 2025
Cited by 3 | Viewed by 999
Abstract
With the maturation of ultra-high-voltage direct current (UHVDC) technology, DC grids are taking on a more critical role in power systems. However, their impact on AC grids has become more pronounced, particularly in terms of frequency, short-circuit current level, and power flow control [...] Read more.
With the maturation of ultra-high-voltage direct current (UHVDC) technology, DC grids are taking on a more critical role in power systems. However, their impact on AC grids has become more pronounced, particularly in terms of frequency, short-circuit current level, and power flow control capabilities, which also affects the power supply reliability of the receiving-end grid. To comprehensively evaluate the balance between AC and DC strength at the receiving-end, this paper proposes a multidimensional assessment system that covers grid strength and operational security under various operating conditions. Furthermore, a rationality evaluation model for the AC/DC strong–weak balance relationship is developed based on the entropy weight method, forming a complete evaluation framework for assessing the AC/DC strong–weak balance in the receiving-end power grid. Finally, to address strength imbalances in grid, a structural optimization method for the receiving-end grid is designed by combining network decoupling techniques with modular multilevel converter-based HVDC (MMC–HVDC), serving as a strategy for enhancing grid stability. The proposed strategy is validated through simulations in a typical test system using PSD-BPA, demonstrating its effectiveness in optimizing power flow characteristics, improving system stability, reducing the risk of short-circuit current overloads and large-scale blackouts, and maintaining efficient system operation. Full article
Show Figures

Figure 1

26 pages, 3954 KB  
Article
Bi-Level Planning of Grid-Forming Energy Storage–Hydrogen Storage System Considering Inertia Response and Frequency Parameter Optimization
by Dongqi Huang, Pengwei Sun, Wenfeng Yao, Chang Liu, Hefeng Zhai and Yehao Gao
Energies 2025, 18(15), 3915; https://doi.org/10.3390/en18153915 - 23 Jul 2025
Cited by 4 | Viewed by 1759
Abstract
Energy storage plays an essential role in stabilizing fluctuations in renewable energy sources such as wind and solar, enabling surplus electricity retention, and delivering dynamic frequency regulation. However, relying solely on a single form of storage often proves insufficient due to constraints in [...] Read more.
Energy storage plays an essential role in stabilizing fluctuations in renewable energy sources such as wind and solar, enabling surplus electricity retention, and delivering dynamic frequency regulation. However, relying solely on a single form of storage often proves insufficient due to constraints in performance, capacity, and cost-effectiveness. To tackle frequency regulation challenges in remote desert-based renewable energy hubs—where traditional power infrastructure is unavailable—this study introduces a planning framework for an electro-hydrogen energy storage system with grid-forming capabilities, designed to supply both inertia and frequency response. At the system design stage, a direct current (DC) transmission network is modeled, integrating battery and hydrogen storage technologies. Using this configuration, the capacity settings for both grid-forming batteries and hydrogen units are optimized. This study then explores how hydrogen systems—comprising electrolyzers, storage tanks, and fuel cells—and grid-forming batteries contribute to inertial support. Virtual inertia models are established for each technology, enabling precise estimation of the total synthetic inertia provided. At the operational level, this study addresses stability concerns stemming from renewable generation variability by introducing three security indices. A joint optimization is performed for virtual inertia constants, which define the virtual inertia provided by energy storage systems to assist in frequency regulation, and primary frequency response parameters within the proposed storage scheme are optimized in this model. This enhances the frequency modulation potential of both systems and confirms the robustness of the proposed approach. Lastly, a real-world case study involving a 13 GW renewable energy base in Northwest China, connected via a ±10 GW HVDC export corridor, demonstrates the practical effectiveness of the optimization strategy and system configuration. Full article
(This article belongs to the Special Issue Advanced Battery Management Strategies)
Show Figures

Figure 1

20 pages, 1881 KB  
Article
Assessment of Regulation Capacity Requirements for Sending-End Grids Considering Frequency Security
by Min Li, Xiaodi Wang, Fang Liu, Xiaming Guo, Dawei Chen and Yunfeng Wen
Energies 2025, 18(13), 3577; https://doi.org/10.3390/en18133577 - 7 Jul 2025
Viewed by 989
Abstract
With the large-scale integration of converter-based renewable energy into power systems and the large-scale construction of HVDC, risks associated with supply–demand imbalance and post-contingency frequency instability of sending-end power grids have significantly escalated. This paper proposes a novel method for evaluating the regulation [...] Read more.
With the large-scale integration of converter-based renewable energy into power systems and the large-scale construction of HVDC, risks associated with supply–demand imbalance and post-contingency frequency instability of sending-end power grids have significantly escalated. This paper proposes a novel method for evaluating the regulation capacity requirements of sending-end grids, addressing both normal-state power balance and post-disturbance frequency security. In normal states, multiple flexible metrics that can quantify the supply–demand imbalance trend are introduced. Then, thermal power units and energy storage serve as the benchmark to quantify the specific capacity requirements. For post-contingencies, frequency security metrics are derived based on the system frequency dynamic model with synchronous generators, renewable energy, and energy storage. The derived frequency security metrics can quantify the credible frequency regulation capacity required to ensure system stability under a predefined disturbance. A multi-objective capacity requirement assessment model for both the normal state and the post-contingency frequency regulation is ultimately formulated to determine the minimum capacity requirements. The effectiveness of the proposed evaluation method is verified using the numerical simulation based on a practical sending-end grid. Full article
(This article belongs to the Special Issue Advances in Sustainable Power and Energy Systems: 2nd Edition)
Show Figures

Figure 1

14 pages, 1566 KB  
Article
Risk Assessment Model for Converter Transformers Based on Entropy-Weight Analytic Hierarchy Process
by Guochao Qian, Weiju Dai, Dexu Zou, Haoruo Sun, Hanting Zhang and Jian Hao
Energies 2025, 18(7), 1757; https://doi.org/10.3390/en18071757 - 1 Apr 2025
Cited by 10 | Viewed by 1525
Abstract
As a critical component in voltage–current conversion and power transmission within HVDC systems, the risk assessment of converter transformers plays a significant role in ensuring their operational safety and enhancing the reliability of the power supply. To address the issues of the incomplete [...] Read more.
As a critical component in voltage–current conversion and power transmission within HVDC systems, the risk assessment of converter transformers plays a significant role in ensuring their operational safety and enhancing the reliability of the power supply. To address the issues of the incomplete characteristic parameters and limited fault data used for model training in existing transformer evaluation models, this paper develops a risk assessment model for converter transformers based on the entropy-weighted analytic hierarchy process (AHP). Firstly, in accordance with relevant standards in the power industry and existing experimental research, 14 ‘electrical–thermal–mechanical’ multi-dimensional characteristic parameters, including partial discharge, dissolved gases in oil, and hot spot temperature rise, are selected to effectively reflect the risk state of converter transformers. The risk state is then categorized into four levels. Next, the AHP, which uses a subjective weighting method, is combined with the entropy-weight method, an objective weighting approach, to construct the risk assessment model for converter transformers based on the entropy-weighted AHP. Finally, the effectiveness of the model is validated through four case studies of converter transformers. The results indicate that the risk assessment model proposed in this paper can accurately and effectively reflect the risk state of transformers at different levels, providing valuable guidance for the development of maintenance strategies for converter transformers. Full article
Show Figures

Figure 1

22 pages, 6069 KB  
Article
Research on Power Efficiency of DC Microgrids Considering Fire Protection Systems
by Ju-Ho Park and Sang-Yong Park
Energies 2025, 18(2), 230; https://doi.org/10.3390/en18020230 - 7 Jan 2025
Viewed by 2397
Abstract
Due to the development of power semiconductors and the increase in digital loads, DC microgrids are receiving attention, and their application scope is rapidly expanding. As the technological stability of high-voltage direct current (HVDC) continues to rise, the potential of low-voltage direct current [...] Read more.
Due to the development of power semiconductors and the increase in digital loads, DC microgrids are receiving attention, and their application scope is rapidly expanding. As the technological stability of high-voltage direct current (HVDC) continues to rise, the potential of low-voltage direct current (LVDC) distribution systems is becoming increasingly intriguing. Many researchers are actively conducting safety and efficiency research on DC distribution systems and power grids. In LVDC distribution systems, small-scale DC microgrids are formed by renewable energy sources supplying DC power. This paper analyzes the efficiency improvement that can be achieved by integrating a fire protection system into a DC microgrid. This research analyzed the changes when fire protection systems such as receivers, transmitters, fire alarms, emergency lighting, and evacuation guidance, which have traditionally used AC power, were converted to DC circuits. As a result, the power supply infrastructure within the DC microgrid can be simplified, energy loss can be reduced, and the stability of the power system can be improved. The research results of this paper suggest that DC circuit-based fire protection facilities can positively impact future smart grid and renewable energy goals. Full article
(This article belongs to the Section A1: Smart Grids and Microgrids)
Show Figures

Figure 1

Back to TopTop