Experimenting with Catalytic Stacks for Ortho-Parahydrogen Conversion in a Thermoacoustic Standing-Wave Engine

,
,
and
Hydrogen Properties for Energy Research (HYPER) Center, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, USA
*
Author to whom correspondence should be addressed.

Abstract

Thermoacoustic oscillations are excited sound waves in systems with large temperature gradients. Thermoacoustic engines and refrigerators can be constructed using porous materials to enhance the acoustic power produced and facilitate heat pumping for refrigeration. Porous materials can also be utilized as catalytic beds to convert between the two spin-isomers of hydrogen: orthohydrogen and parahydrogen. The conversion between ortho- and parahydrogen is either endothermic or exothermic, and the composition of the isomers manipulates the heat capacity of the fluid. This study experimentally investigates ortho-parahydrogen conversion in a thermoacoustic standing-wave engine with different oxidized catalytic materials. Recorded experimental measurements include the onset temperature ratio, acoustic pressure amplitude, and frequency of the thermoacoustic engine. The results depict a relationship between the oxidized materials and the acoustic amplitude. All oxidized materials promoted an increase in acoustic amplitude versus the pure metallic components. Steady-flow conversion was measured for brass oxide and iron oxide pellets; however, no conversion was detected for aluminum oxide or copper oxide pellets. The initial datapoints provide evidence that future cryogenic hydrogen thermoacoustic devices will need to account for the spin isomer conversion inside the stack. New flow-through regenerating liquefiers can also be constructed, which convert orthohydrogen to parahydrogen during liquefaction.

1. Introduction

Thermoacoustic devices employ self-excited sound waves to transfer energy, either producing acoustic power in an engine or pumping heat in a refrigerator. Thermoacoustic systems usually utilize porous matrices (stacks or regenerators) to enhance these processes [1]. The term “stack” is usually associated with a porous medium that has relatively large pore sizes (comparable with acoustic penetration depths) and is employed in standing-wave systems, while “regenerators” typically have smaller pore sizes and are installed in traveling-wave systems. The remainder of this paper references standing-wave systems, so the “stack” terminology is used.
Advances in thermoacoustic devices include manipulating the working fluid mixtures to increase efficiency and the development of new stacks for increased thermal effectiveness. Optimizing the volumetric heat capacity of a material provides the ability to store large amounts of thermal energy in a compact space while still achieving the desired response time [2]. Additionally, different fluid properties affect stack performance through the alteration of different acoustic parameters (e.g., frequency) and dissipation losses [3]. Shenton et al. [4] proved that hydrogen excites easier than helium in cryogenic thermoacoustic systems. Initial findings from Carter and Feldman [5] show that tube bundles with low thermal conductivity in a Sondhauss tube enhanced the acoustic power output, and the power varied at different positions of the pores along the length of the tubing. Arnott et al. [6] expanded upon existing thermoacoustic functions by formulating equations that correlate different pore shapes. Tartibu [7] analyzed 20 configurations of a Celcor® ceramic with square channels in an engine configuration using air. It was found that smaller pore sizes were preferential when the stack length was short compared to the resonator tube and continued to verify that the relationship between the geometry of the stack and acoustic power was non-linear. Matveev et al. [8] developed a simplified model for calculating thermoacoustic power conversions in transverse pin arrays and tortuous media (mesh screens). Tasnim et al. [9] expanded research into heterogeneous stacks with different combinations of Celcor®, Reticulated Vitreous Carbon foam (RVC), and mylar. A combination of RVC and Celcor® produced the largest temperature gradient between the hot and cold heat exchanger and exceeded the pure ceramic stack of 2 cm length. Zolpakar and Mohd-Ghazali [10] investigated stacks with spiral wound geometries, mylar stacked sheets, and 3D-printed materials in a standing-wave refrigerator. The 3D-printed stack produced the largest temperature gradient across the stack. Shenton et al. [11] expanded on current stack research by using hydrogen as the working fluid at cryogenic temperatures and found that mesh screens and spherical pellets had the highest acoustic amplitudes but different onset conditions.
Porous geometries are also utilized to accelerate the conversion of orthohydrogen to parahydrogen in catalytic reactors. Experimental studies have characterized the design of packed beds to optimize conversion in liquefaction systems. Guo et al. [12] summarized empirical pressure drop correlations and porosity predictions for randomly packed beds of mono-sized spheres and experimentally verified the validity of each equation. The main conclusion shows that using packed beds with small tube to particle diameter ratios can lead to differences in porosity and pressure drop for the same packing density of the spheres, and each empirical correlation provides these different values. Wang et al. [13,14] studied both tubular reactors with mesh screens and catalyzed plate-fin heat exchangers relating conversion to the space velocity of the hydrogen flowing through the system. These findings indicate that a higher space velocity reduces conversion efficiency as the particles decrease the residence time next to the catalyst and that increasing the mesh size reduces conversion, counteracting the increased surface area with high space velocity. Nast and Hu [15] studied the design of a catalytic converter in the vent line of hydrogen systems to induce the endothermic reaction from para- to orthohydrogen to achieve cooling. This along with other systems [16] suggests the feasibility of utilizing reactors for additional cooling rather than pure liquefaction purposes.
New regenerating liquefiers can be utilized to directly convert ortho-parahydrogen to reduce boil-off losses and increase the exergy of the stored hydrogen fuel. A potentially robust and efficient liquefier is a scaled flow-through cryocooler directly converting ortho-parahydrogen in a storage vessel [17]. Additionally, using hydrogen as the working fluid with a catalytic regenerator could augment the performance of current cryocoolers [18]. The present study is motivated by the importance of generating and storing liquid hydrogen efficiently. This work aims to characterize the effect of common catalytic materials for conversion rate constants and performance in a cryogenic standing-wave thermoacoustic system as stacks. A discussion of ortho-parahydrogen and stack material theory is given in Section 2. The experimental apparatuses are presented in Section 3. The obtained catalytic and thermoacoustic measurements using different insert materials with both hydrogen and helium are analyzed in Section 4.

2. Catalyzation and Stack Theory

2.1. Ortho-Parahydrogen Catalysis

The diatomic hydrogen molecule has two quantum ‘spin’ isomers described using the vibrational, rotational, electronic, and nuclear spin functions from the wave equation. Orthohydrogen has a symmetric nuclear spin state and parahydrogen has an antisymmetric nuclear spin state to ensure continuity with the wave equation. At room temperature, the equilibrium fraction of orthohydrogen is about 75%, which is designated as normal hydrogen, while at the saturated state of 20 K, the orthohydrogen fraction is about 0.2% as most molecules exist in the parahydrogen state. The spin conversion of hydrogen isomers from predominantly orthohydrogen to parahydrogen occurs primarily below 150 K, reaching a temperature dependent equilibrium composition. The reaction converting from ortho- to parahydrogen is exothermic, releasing about 703 kJ/kg below 50 K, which is greater than the heat of vaporization of hydrogen (446 kJ/kg) near the normal boiling point (20.37 K). This phase change is reversible as an endothermic reaction when para- converts to orthohydrogen.
Three criteria including satisfying the ortho-parahydrogen quantum selection rules, transferring the necessary angular momentum, and providing the necessary energy are required for the conversion between the spin states of the hydrogen molecule [19]. An induced electromagnetic torque applied with the dipole of an oxide material on the diatomic molecule satisfies all these rules [20]. Abe et al. [20] grouped different oxide catalysts based on the rate constants for conversion and discussed the ionic radius comparison between the oxide material and the hydrogen molecule. It is noted that as the ionic radius of the oxidized material exceeds the ionic radius of the hydrogen molecule, the electric field is more isotropic, which decreases the effectiveness of catalyzation. Many high-activity catalysts also include lanthanide elements (i.e., erbium, holmium, etc.), due to the ability of these materials to develop oxygen vacancies in the surface, providing more potential binding sites for the hydrogen molecules to access.

2.2. Stack Parameters

A high-performing stack is dictated by the interaction between the stack and the working fluid. The utilization–NTU method is a lumped parameter model which describes the relationship between the stack and working fluid [21]. Two key non-dimensional numbers are defined as the number of heat transfer units (NTU) and the utilization factor (U), which are shown mathematically as:
N T U = h A s m ˙ C p , f ,
h = m ˙ C p , f j h A c P r 2 3 ,
U = m ˙ C p , f t ρ r C r V r ,
where h is the convective heat transfer coefficient, A s and A c are the surface area and cross-sectional area, C p , f and C r are the heat capacity of the fluid and regenerator, respectively, m ˙ is the mass flow rate, t is the time for the fluid to pass through the regenerator, j h is the Colburn factor, P r is the Prandtl number, and ρ r and V r are the density and the volume of the regenerator. A low utilization factor and large number of heat transfer units promote a high-performing stack. The specific heat capacity of the material and fluid can be manipulated to improve the performance of the stack. Lanthanides are also widely used as regenerator materials to achieve cryogenic temperatures near 4 K, due to the magnetic phase transition of these materials at low temperatures, which increases the effective heat capacity. These materials are expensive to fabricate, and systems need to achieve low cryogenic temperatures to take advantage of the increased heat capacity. However, for hydrogen systems that need to only achieve 20 K, more common materials such as stainless steel or copper can be used as cheaper alternatives [22].

2.3. Selection of Catalytic Stack Materials

The materials chosen must be able to be oxidized effectively, be compatible with hydrogen, and provide the electric torque at a molecular scale necessary for conversion. Accessible stack materials are shown in Figure 1, comparing the expected catalytic efficiencies calculated from Abe et al. [20] and the integrated average volumetric heat capacities taken from the NIST regenerator database [23]. It is noted that the volumetric heat capacity is calculated assuming a pure material as the oxide layer is considered negligibly thin on the surface. Theoretical calculations by the authors show that the proposed oxide layer varies the overall heat capacity of the material by 0.025%. It is shown that brass, copper, and nickel with an oxide layer are expected to increase the catalytic efficiency by approximately double the industry standard of Ionex® (iron oxide). These materials also have volumetric heat capacities within the same order of magnitude as common regenerator materials in conventional cryocoolers on the market.
Figure 1. Integrated average volumetric heat capacity (20 K–77 K) of pure metallic materials compared to predicted catalyst efficiency relative to iron oxide.
Material reactions to the hydrogen molecule can cause embrittlement. Lee and Woods [24] provided a comprehensive study discussing the mechanisms of hydrogen embrittlement with different materials. Nickel is described as having a high susceptibility to embrittlement when exposed to a pure hydrogen environment, which precludes nickel for being an effective catalyst. Aluminum does not embrittle when in contact with hydrogen, but is a known non-catalyst for the reaction [25]. Copper and brass also do not embrittle when exposed to hydrogen and are chosen as material candidates to investigate along with iron (for comparison to conventional catalysts) and aluminum.

3. Experimentation

Two experimental apparatuses are utilized to measure the performance of hydrogen catalytic stacks: a cryogenic standing-wave thermoacoustic engine which characterizes the performance of the stack materials, and a cryogenic Raman spectroscopy probe to determine ortho-parahydrogen conversion in steady flow. The highest pressure-amplitude and lowest temperature gradient required for thermoacoustic oscillations in the engine and the conversion constants for ortho-parahydrogen conversion are the primary metrics of interest.

3.1. Standing-Wave Thermoacoustic Engine

3.1.1. Experimental Apparatus for the Standing Wave Engine

A closed cryostat with a Sumitomo RDK415D2 cryocooler (Allentown, PA, USA) is utilized to create the cryogenic environment which is described by Shenton et al. [26]. The system is shown in Figure 2, which has been employed in previous non-catalytic experimental studies published by the authors [11]. The thermoacoustic engine is excited similar to Taconis oscillations through a cryogenic temperature gradient. The key components of this system are designed as a thermal dead end while also allowing for cold temperature control, regulation of the mean pressure inside the experimental tube, and temperature measurements along the system (shown by red diamonds in Figure 2).
Figure 2. Experimental cryostat diagram with thermoacoustic engine. Red diamond symbols indicate temperature sensor locations. Crosshatched regions indicate stack material locations.
An inlet duct and heat exchanger are mounted to the roof of the cryostat to introduce the working fluid. This heat exchanger is supplied with an input wattage via a cartridge heater to maintain a boundary condition of approximately 300 K. Pipes are connected to the cryostat roof on the inside of the vacuum chamber to form the thermoacoustic system. The stainless-steel thermal standoff is filled with stack material and connected to the copper thermal busbar to generate acoustic power. Another stainless-steel thermal standoff is connected below the thermal busbar to connect to the acoustic resonator network that includes the inertance tube and compliance. Indium metal is used as a sealant at all connections on the tubing in the vacuum chamber. The compliance is connected back to the thermal busbar with a thermal strap to transfer acoustic energy dissipated in the compliance through the cryocooler. A copper and multi-layered insulation (MLI) shield encloses experimental components to reduce radiative heat transfer from the cryostat walls. Table 1 gives the main dimensions of the thermoacoustic system.
Table 1. Geometry of thermoacoustic system.

3.1.2. Instrumentation for Thermoacoustic Apparatus

First, 50 W and 100 W Lakeshore™ (Westerville, OH, USA) cartridge heaters, connected to an external power supply and embedded into the thermal busbar, are used to maintain the desired cold boundary temperature. A final 50 W cartridge heater is inserted into the ambient heat exchanger to keep a constant warm boundary condition.
A PCB™ model 11b321 dynamic pressure transducer records the acoustic pressure oscillations at the inlet duct. The mean pressure is measured by a digital pressure transducer. Two Omega™ type K thermocouples (sensors 1–2) are inserted into the copper ambient heat exchanger. These temperatures are recorded utilizing an Omega™ datalogger. Cernox® sensors from Lakeshore™ are installed on the thermal busbar and the stack tube (sensors 3–4). Sensors 5 and 6 are calibrated silicon diodes acquired from Lakeshore™. The instrumentation for measuring the acoustic pressure, frequency, and temperature profile is summarized in Table 2.
Table 2. Instrumentation used in thermoacoustic experimental studies.

3.1.3. Experimental Thermoacoustic Processes

The start of an experimental study requires a designated mean pressure of the system. Ultra-high purity (99.999%) helium and normal hydrogen are regulated into the system through the inlet valve at the top of the system. After reaching the desired mean pressure, the inlet valve is closed. The system is maintained at a constant mass for the duration of the experimental measurements. Then, the cryocooler is started, and cooling occurs on the thermal busbar. The temperature difference between the thermal busbar and the ambient environment is adjusted using the cartridge heaters in the thermal busbar. A power supply introduces a constant amperage, and the voltage is measured in a 4-lead arrangement as described by Ekin et al. [27]. The recorded data consists of the acoustic pressure amplitude, acoustic frequency, and temperature values. A Labview™ program records these values using the Tone Measurements library [28,29], which utilizes a Fast Fourier Transform to find and output the dominant tonal frequency and corresponding pressure amplitude. The main parameters are continuously measured and recorded in the Labview™ 2024 Q3 program.
After the system temperature falls below 120 K, the cartridge heaters activate to maintain the cold temperature of the system at desired values using a proportional, integral, derivative (PID) algorithm. The system is allowed to reach steady state at the specified cold temperature. This is determined by consistent temperature readings within the sensor uncertainty for a period of 15 min. The thermal busbar is then set to decrease by 10 K increments by reducing the power supplied to the heaters embedded in the thermal busbar. This process continues until no external heat from the cartridge heater is applied to the system. After the system has reached equilibrium with no external heat applied, the temperature of the thermal busbar is set to increase by 10 K increments using heaters.

3.2. Ortho-Parahydrogen Conversion

3.2.1. Experimental Apparatus for Ortho-Parahydrogen Conversion

A secondary cryostat liquifies approximately 6.7 L of hydrogen to measure the efficiency of catalytic beds for ortho-parahydrogen conversion. A detailed discussion of the experimental setup and validation is given by Bunge et al. and Appel et al. [30,31]. Figure 3 depicts the experimental apparatus inside the vacuum chamber. This cryostat utilizes a Sumitomo RDK500E cryocooler. Hydrogen gas is pressurized in tanks connected to the cryocooler for liquefaction and converted to 99.8% parahydrogen using Ionex®. Catalytic reactors are installed into an isothermal copper block (butterfly) and connected to the cryocooler to accurately measure the conversion efficiency along the temperature curve of flowing hydrogen. The volume of the catalytic reactor is approximately 1 × 10−5 m3. Liquid hydrogen flows from the tanks out of the system through the reactors to determine the conversion from parahydrogen to orthohydrogen. A cartridge heater is embedded into the system to control the isothermal temperature at each measurement condition. Raman spectrometers from StellarNet (Tampa, FL, USA) are used on the inlet and outlet of each reactor tube to measure the change in Anti-Stokes scattering of the hydrogen rotational levels. The Anti-Stokes scattering determines the orthohydrogen fraction at a given temperature after the hydrogen is excited using a laser, and the spectra for the J = 0 and J = 1 rotational levels are measured.
Figure 3. Experimental apparatus for analyzing ortho-parahydrogen conversion.

3.2.2. Instrumentation for Ortho-Parahydrogen Conversion Apparatus

A 50 W Lakeshore™ cartridge heater is installed inside the liquid hydrogen tanks to vaporize the liquid flowing through the reactor. Another 50 W Lakeshore™ cartridge heater is embedded into the copper butterfly to maintain isothermal temperature on the reactor. The Raman spectroscopy system utilizes a StellarNet™ (Tampa, FL, USA) Raman HR-TEC-532 spectrometer and a Laser Quantum™ (Bedford, MA, USA) Gem 532-CW 532 nm laser with horizontal polarization. The laser shines through a custom-made Raman filter [31] to excite and measure the scattering by the flowing hydrogen. Four silicon diode temperature sensors are installed onto the cryocooler, the copper butterfly, and the inlet and outlet Raman cells. The main instrumentation for this cryostat is listed in Table 3.
Table 3. Instrumentation for conversion experimental studies.

3.2.3. Experimental Processes for Conversion

These experimental studies start with inserting and activating the catalyst material in the reactor tubes. The entire system is purged using 99.999% pure helium gas at 100 psig. To remove the absorbed water attached to the surface of the catalyst material, helium gas is allowed to flow through the reactor bed out of the system at a rate of 0.2 SLPM. To accelerate the process, the butterfly copper block is heated to 373 K. This activation procedure is performed for five hours to desorb all the water on the catalyst beads. Once the activation procedure is completed, the system is purged with 99.999% hydrogen to begin the liquefaction process. The cryocooler is started, and hydrogen is allowed to condense and fill the tanks inside the cryostat.
Once liquefaction is finalized, an experimental measurement testing campaign begins. Before data can be measured, a dark spectrum is taken with the Raman spectrometers for calibration. This dark spectrum is captured for one minute using an exposure time of 59 s. After the spectrometers are calibrated before hydrogen enters the reactors, a cartridge heater is activated in the liquid hydrogen tanks for vaporization. This hydrogen vapor flows through an additional feed heater to warm the hydrogen to the desired temperature. Then the vapor flows through the reactor to convert from parahydrogen to orthohydrogen. Experimental measurements are taken at three different temperatures (45 K, 60 K, 90 K) and three different flowrates (1 SLPM, 2 SLPM, 4 SLPM) through the reactor. At a given temperature, the flowrate out of the reactor is set using an Alicat mass flow controller. The spectra from the flowing hydrogen before and after the reactor are recorded for all flow rates using the software package StellarNet™ (Tampa, FL, USA) Spectroscopy-Pro Tools 1.2.11 [32]. The hydrogen vapor is then vented through a vent stack. Then, the butterfly is heated to the next temperature setpoint. After the last temperature setpoint and all flowrates, the system is allowed to warm to ambient conditions for another catalyst material. The spectra are analyzed using a Python 3.9 program described in Appel and Leachman [30]. This determines the orthohydrogen fraction present after the outlet tube. The activity coefficient is calculated using the space velocity equation implemented into the python code.

3.3. Stack Materials

Different metallic materials are tested in a packed bed for thermoacoustic performance and ortho-parahydrogen conversion. Iron, aluminum, brass, and copper pellets with a diameter of 2.5 mm are utilized. In the thermoacoustic engine, this equates to a hydraulic pore radius of 0.4 mm and a porosity of 0.4 for the stack. This geometry was chosen as thermoacoustic oscillations were produced in this system previously [11], and a packed-bed reactor typically uses spherical geometries. All materials chosen in Section 2.3 are catalyzed by growing an oxide layer on the surface of the pure material and are verified to have the same geometric properties within the uncertainty of the calipers. The performance of the pure elemental spheres is initially measured in both systems before catalyzation occurs.

Catalyzation Process of the Stack Materials

The catalyzation process utilizes a seven-molar potassium-hydroxide (KOH) solution to create an oxide layer on the surface of the spheres. Initially, the pure metallic spheres are cleaned using de-ionized (DI) water and dried in a closed inert helium environment. Figure 4a depicts pure brass spheres before the catalyzation process. The mass and diameter of the pure spheres are measured. Then, the beads are immersed in the KOH solution for approximately 5 min to complete the reaction. Figure 4b shows the initial solution with the beads. After the reaction is completed, the oxidized beads are rinsed with DI water. The rinsing process is completed multiple times until the solution has been diluted. The spheres are again measured for diameter and mass to ensure that the geometric properties have not been manipulated during the catalyzation process. Finally, the spheres are placed in a new container on a hot plate in an inert helium environment to vaporize remaining water and prevent further oxidation with the air. The spheres are re-installed into the thermoacoustic system for testing, as shown in Figure 4c, and installed into the reactor tube shown (Figure 4d). Filter paper was utilized as a funnel to insert the spheres into the reactor tube. A volumetric flask captured excess spheres during the installation process.
Figure 4. The oxidation process for catalyzation includes (a) pure brass spheres, (b) brass spheres in solution during catalyzation, (c) final oxidized spheres installed into engine stack and (d) final oxidized sphere installation into the packed bed reactor.

4. Results and Discussion

The different stack materials discussed above are tested for thermoacoustic performance and ortho-parahydrogen conversion rates. To quantify the difference in performance effects due to catalysis and the oxide layer separately, experimental measurements are also recorded using helium as the working fluid for a subset of materials. Additionally, hydrogen was tested across an aluminum and aluminum oxide-packed bed, which is a known non-catalyst for this phase change, but is utilized as a support material for substrate catalytic materials [25].

4.1. Thermoacoustic Performance

4.1.1. Comparison of Pure and Oxidized Metallic Stack Materials with Hydrogen

The four different materials are characterized with hydrogen. One example using brass as the stack material is shown in Figure 5. Hysteresis is noted between the onset and attenuation of oscillations, dependent on the direction of the temperature of the thermal busbar. This is consistent with the previous findings of the authors [11], and the primary values reported are measured when the busbar temperature is decreasing. The pure brass pellets are installed into the thermoacoustic stack and measured for the onset of oscillations, the pressure amplitude, frequency, and pressure ratio. The brass pellets achieved a maximum pressure amplitude of 8.6 kPa (Figure 5a). The frequency ranged from approximately 180 Hz to 120 Hz (Figure 5c), as frequency is a function of the fluid properties, which vary with temperature. The maximum pressure ratio between the acoustic pressure and the mean pressure is 6.7%. The parabolic shape of the pressure oscillations can be attributed to the change in mean pressure as the cold section decreases in temperature. The pellets are then oxidized to determine the effective change of a catalytic material. There is an increase in pressure amplitude when the brass pellets are oxidized. The maximum pressure amplitude increases to approximately 9.4 kPa (Figure 5b). The frequency is similar as the geometry of the system and the working fluid stay consistent (Figure 5d). Minimal variation in the frequency is expected as the stack material porosity and hydraulic radius are assumed to be constant. An increase in the pressure ratio is shown in Figure 5f as the maximum ratio reaches approximately 7.4%.
Figure 5. Experimental data for acoustic pressure amplitude, acoustic frequency, and non-dimensional pressure amplitudes for (a,c,e) brass pellets with hydrogen and (b,d,f) oxidized brass pellets with hydrogen.

4.1.2. Performance Comparison Between Hydrogen and Helium

To continue to investigate the increase in amplitude by the oxide layer, hydrogen oscillations were compared to helium oscillations using iron and iron oxide beads (Figure 6). For both the pure iron and iron oxide, hydrogen had a higher cold onset temperature than helium and achieved larger pressure amplitudes for similar mean pressures. The maximum amplitude for the iron pellets for helium is approximately 8.0 kPa (Figure 6a), while the maximum amplitude for hydrogen in the same configuration is approximately 8.8 kPa (Figure 6g). A similar trend follows for iron oxide, with a maximum amplitude of approximately 9.2 kPa for hydrogen (Figure 6h) and 8.5 kPa for helium (Figure 6b). The frequencies for both configurations with helium (Figure 6c,d) are lower than with hydrogen, starting near 130 Hz and ending near 85 Hz. Hydrogen oscillates with a frequency (Figure 6i,j) of 190 Hz and decreases to 120 Hz as the cold boundary temperature is lowered. The ratio of pressure amplitude to the mean pressure reached a maximum at the coldest temperature for all configurations and fluids. The maximum pressure ratio with helium for iron (Figure 6e) and iron oxide (Figure 6f) is 6.4% and 6.7%, respectively. The helium values are comparatively lower than hydrogen. When hydrogen is used in the system, the pressure ratio achieved is 6.8% (Figure 6k) and 7.2% (Figure 6l) for iron and iron oxide, respectively. These experimental measurements portray the possibility of an effect due to the oxide layer of the stack material rather than an effect of conversion inside the stack during oscillations.
Figure 6. Comparisons of experimental measurements of acoustic pressure amplitude, acoustic frequency, and non-dimensional pressure amplitude for (a,c,e) iron with helium, (b,d,f) iron oxide with helium, (g,i,k) iron with hydrogen, and (h,j,l) iron oxide with hydrogen.

4.1.3. Thermoacoustic Performance Comparisons Between Stacks

Comparisons between stack materials are shown in Figure 7. The onset temperature ratios increase slightly for the oxidized pellets compared with the pure elements (Figure 7a). Overall, the onset temperature ratio for all spherical materials tested was between 3.8 and 4.3. The uncertainty for the onset temperature measurement is 2 K or an alpha of 0.1. The differences could be due to the increased surface area on the pellet, resulting in higher dissipative losses. Iron and iron oxide pellets with hydrogen are outliers from this trend as the onset temperature ratio decreases. The experimental data depicts a larger onset temperature ratio using helium rather than hydrogen which aligns with other publications by the authors. The iron oxide onset temperature ratio increases compared to the pure iron with helium in contrast to the outlier with hydrogen.
Figure 7. Comparisons of (a) onset temperature ratio, and (b) experimental acoustic pressure amplitudes for different catalytic and non-catalytic materials. Uncertainties are not included to preserve readability of the figures.
The acoustic performance of each stack material is depicted in Figure 7b. The total uncertainty of the acoustic amplitude measurement is 0.16 kPa. Pure iron led to a larger amplitude of pure copper and pure brass. Additional material characteristics such as thermal diffusivity and conductivity were taken from the NIST database [23]. Iron has a larger thermal diffusivity than brass but a smaller conductivity than copper. With these material properties, pure iron can transiently propagate thermal waves faster than brass while reducing the axial conduction down the stack when comparing the thermal conductivity to copper.
Overall, oxidizing the pellets leads to a higher acoustic pressure amplitude. This could also be attributed to the oxide layer decreasing the surface contacts between each bead, potentially reducing the axial conduction down the stack improving the thermal transfer from the hydrogen to the beads. Upon visual inspection, the oxide layer did not appear to flake away from the sphere during acoustic testing. These results indicate that the use of materials with a high heat capacity and thermal conductivity can be utilized. Copper oxide increases the pressure amplitude by an average of approximately 11% from pure copper. The average pressure increase from aluminum to aluminum oxide and brass to brass oxide is approximately 8% and 7%, respectively. Iron and iron oxide had smaller increases in performance, with an average of 2% for hydrogen and 4% for helium. These trends depict a positive effect of oxidizing porous materials and utilizing them as stacks/regenerators with hydrogen for ortho/parahydrogen conversion. Using a previous thermoacoustic model [11], the orthohydrogen fraction change was calculated at the midpoint of the stack. The oscillatory temperature is approximately 2 K with a mean temperature of approximately 70 K. The orthohydrogen fraction is 0.46 and 0.42, which corresponds to 72 K and 68 K, respectively. The power released associated with this conversion is approximately 2.0 W, or 10% of the local thermoacoustic heat streaming, assuming perfect conversion.

4.2. Steady-Flow Catalysis Efficiency

After the thermoacoustic measurements, the oxidized beads are measured in a packed bed reactor for catalytic activity converting parahydrogen to orthohydrogen. The conversion values for the different flowrates and catalyst materials are shown in Figure 8. The iron oxide beads measured a lower volumetric conversion rate (1.9 1/s) than commercial Ionex® (29.8 1/s [30]) at 60 K. This is due to a different composition of iron oxide forming (Fe3O4) rather than Fe2O3 (Ionex®) and geometric differences between Ionex® powder and the tested spheres. The packing porosity and internal volume of the spheres reduces the activity of the reactor due to the decrease in activation sites available inside the tube. The brass oxide had slightly lower catalytic activity (1.1 1/s at 60 K) than the iron oxide spheres. The copper oxide did not convert para- to orthohydrogen within this reactor. These deviations could be due to the activation time or a suboptimal flow rate. The activation time for each of the catalyst materials is kept constant at 5 h. However, each catalytic material requires different activation time constants to desorb the water from the surface of the catalyst, improving access to the catalyzation sites. The flow rates across the catalytic bed are also kept constant during experimental measurements.
Figure 8. Comparison of different catalytic materials to the equilibrium orthohydrogen curve.

5. Conclusions

Different catalytic materials were experimentally analyzed to explore the effects of ortho-parahydrogen conversion in a regenerator with acoustic pressure oscillations. Measurements of onset temperature ratio, pressure amplitude, frequency, and conversion rates were obtained. The measurements presented show (1) that most of the chosen catalysts converted ortho- to parahydrogen in a steady flow packed bed and (2) all oxide layer materials tested increased the pressure amplitude regardless of fluid or material. This initial evidence suggests additional design considerations for catalytic stacks to enhance acoustic oscillations through a combination of ortho-para composition and stack material properties. Future research directions include analyzing the differences in conversion rates between a steady flow system and an oscillating system, quantifying the contact resistances between the pure metallic elements and the oxidized pellets, utilizing different geometric configurations to solidify catalytic efficiency calculations, and characterizing the surface phenomenon at the oxide layer.

Author Contributions

Conceptualization, M.S., N.J., J.L. and K.M.; methodology, M.S., N.J., J.L. and K.M.; software, N.J. and J.L.; validation, M.S., N.J. and J.L.; formal analysis, M.S., N.J., J.L. and K.M.; investigation, M.S. and N.J.; resources, J.L.; data curation, M.S. and N.J.; writing—original draft preparation, M.S.; writing—review and editing, N.J., J.L. and K.M.; visualization, M.S. and N.J.; supervision, J.L. and K.M.; project administration, J.L. and K.M.; funding acquisition, J.L. and K.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded in part by the U.S. National Science Foundation, grant number 2214235 and the Carson Fellowship.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

We extend our gratitude to Kyle R. Appel for his help with catalytic data collection and maintenance of the experimental facility.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Swift, G.W. Thermoacoustics: A Unifying Perspective for Some Engines and Refrigerators; Acoustical Society of America: Mellville, NY, USA, 2003. [Google Scholar]
  2. Popov, D.; Fikiin, K.; Stankov, B.; Alvarez, G.; Youbi-Idrissi, M.; Damas, A.; Evans, J.; Brown, T. Cryogenic heat exchangers for process cooling and renewable energy storage: A review. Appl. Therm. Eng. 2019, 153, 275–290. [Google Scholar] [CrossRef] [Scilit]
  3. Radebaugh, R. Cryocoolers: The state of the art and recent developments. J. Phys. Condens. Matter 2009, 21, 164219. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Shenton, M.P.; Leachman, J.W.; Matveev, K.I. Investigating Taconis oscillations in a U-shaped tube with hydrogen and helium. Cryogenics 2024, 143, 103940. [Google Scholar] [CrossRef] [Scilit]
  5. Feldman, K.; Carter, R. A study of heat driven pressure oscillations in a gas. J. Heat. Transf. 1970, 92, 536–540. [Google Scholar] [CrossRef] [Scilit]
  6. Arnott, W.P.; Bass, H.E.; Raspet, R. General formulation of thermoacoustics for stacks having arbitrarily shaped pore cross sections. J. Acoust. Soc. Am. 1991, 90, 3228–3237. [Google Scholar] [CrossRef] [Scilit]
  7. Tartibu, L. Impact of ceramic substrates geometry on the performance of simple thermo-acoustic engines. Exp. Tech. 2018, 42, 155–176. [Google Scholar]
  8. Matveev, K.I. Thermoacoustic energy analysis of transverse-pin and tortuous stacks at large acoustic displacements. Int. J. Therm. Sci. 2010, 49, 1019–1025. [Google Scholar] [CrossRef] [Scilit]
  9. Tasnim, S.H. An experimental study on heterogeneous porous stacks in a thermoacoustic heat pump. J. Energy Resour. Technol. 2017, 139, 042005. [Google Scholar] [CrossRef] [Scilit]
  10. Zolpakar, N.; Mohd-Ghazali, N. Comparison of a thermoacoustic refrigerator stack performance: Mylar spiral, celcor substrates and 3D printed stacks. Int. J. Air-Cond. Refrig. 2019, 27, 1950021. [Google Scholar] [CrossRef] [Scilit]
  11. Shenton, M.P.; Leachman, J.W.; Matveev, K.I. Study of Taconis-Based Cryogenic Thermoacoustic Engine with Hydrogen and Helium. Energies 2025, 18, 4114. [Google Scholar] [CrossRef] [Scilit]
  12. Guo, Z.; Sun, Z.; Zhang, N.; Cao, X.; Ding, M. Mean porosity variations in packed bed of monosized spheres with small tube-to-particle diameter ratios. Powder Technol. 2019, 354, 842–853. [Google Scholar] [CrossRef] [Scilit]
  13. Wang, K.; Teng, J.; Wei, X.; Zhu, S.; Fang, S.; Qiu, L. Experimental investigation of thermal and conversion performance of catalysts-filled plate-fin heat exchangers for hydrogen liquefaction. Int. J. Hydrogen Energy 2024, 110, 814–825. [Google Scholar] [CrossRef] [Scilit]
  14. Wang, K.; Xu, S.; Zheng, J.; Zhu, S.; Fang, S.; Xiao, H. Experimental study on catalytic conversion and flow characteristics of ortho-para hydrogen in tubular packed-bed converters at liquid nitrogen temperature. Cryogenics 2025, 147, 104041. [Google Scholar] [CrossRef] [Scilit]
  15. Nast, T.; Hsu, I. Development of a para-orthohydrogen catalytic converter for a solid hydrogen cooler. Adv. Cryog. Eng. 1984, 29, 723–731. [Google Scholar] [CrossRef] [Scilit]
  16. Pedrow, B.P.; Krishna, S.K.M.; Leachman, J.W.; Shoemake, E.D.; Matveev, K.I. Parahydrogen-orthohydrogen conversion on catalyst loaded scrim for vapor cooled shielding of cryogenic storage vessels. J. Thermophys. Heat Transf. 2020, 35, 142–151. [Google Scholar]
  17. Matveev, K.; Leachman, J. Analysis of standing-wave stack for direct cooling and ortho-parahydrogen conversion of cryogenic hydrogen. Cryogenics 2024, 139, 103828. [Google Scholar] [CrossRef] [Scilit]
  18. Matveev, K.I.; Leachman, J.W. Thermoacoustic flow-through cooler for cryogenic hydrogen. Comput.-Aided Chem. Eng. 2022, 49, 1891–1896. [Google Scholar] [CrossRef] [Scilit]
  19. Leachman, J.W.; Wilhelmsen, Ø.; Matveev, K.I. Cool Fuel: The Science and Engineering of Cryogenic Hydrogen; Oxford University Press: Oxford, UK, 2025. [Google Scholar]
  20. Abe, H.; Mizoguchi, H.; Eguchi, R.; Hosono, H. Exploration of heterogeneous catalyst for molecular hydrogen ortho-para conversion. Exploration 2024, 4, 0040. [Google Scholar]
  21. Barron, R.; Nellis, G. Cryogenic Heat Transfer; CRC Press: Boca Raton, FL, USA, 2017. [Google Scholar]
  22. Ackermann, R. Cryogenic Regenerative Heat Exchangers; Springer Science and Business Media: Berlin, Germany, 2013. [Google Scholar]
  23. Material Properties: Regenerator Materials. National Institute of Standards and Technology. Available online: https://trc.nist.gov/cryogenics/materials/RegeneratorMaterials/Regenerator%20Materials%20rev%2009-22-06.htm (accessed on 7 October 2025).
  24. Lee, J.; Woods, S. Hydrogen Embrittlement, NASA Technical Memorandum. Report No. NASA/TM-2016-218602. NASA: Washington, DC, USA, 2016.
  25. Zhuzhgov, A.; Krivoruchko, O.; Isupova, L.; Mart’yanov, O.; Parmon, V. Low-temperature conversion of ortho-hydrogen into liquid para-hydrogen: Process and catalysts. Rev. Catal. Ind. 2018, 10, 9–19. [Google Scholar] [CrossRef] [Scilit]
  26. Shenton, M.; Leachman, J.; Matveev, K. Development of a research cryostat for direct thermoacoustic cooling and conversion of hydrogen. IOP Conf. Ser. Mater. Sci. Eng. 2024, 1301, 012069. [Google Scholar] [CrossRef] [Scilit]
  27. Ekin, J. Experimental Techniques for Low-Temperature Measurements: Cryostat Design, Material Properties and Superconductor Critical-Current Testing; Oxford University Press: Oxford, UK, 2006. [Google Scholar]
  28. LabVIEW Sound and Vibration Toolkit User Manual, National Instruments Corporation. 2004. Available online: https://docsamples.wordpress.com/wp-content/uploads/2012/02/svt_um.pdf (accessed on 1 September 2025).
  29. Tone Measurements, National Instruments. 2024. Available online: https://www.ni.com/docs/en-US/bundle/labview-api-ref/page/vi-lib/express/express-analysis/toneblock-llb/ex-inst-tone-measurements-vi.html (accessed on 1 September 2025).
  30. Appel, K.; Leachman, J. Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions. IOP Conf. Ser. Mater. Sci. Eng. 2024, 1301, 012054. [Google Scholar] [CrossRef] [Scilit]
  31. Bunge, C. A High-Fidelity, Continuous Ortho-Parahydrogen Measurement and Conversion System. Doctoral Dissertation, Washington State University, Pullman, WA, USA, 2021. [Google Scholar]
  32. Spectrogryph, version 1.2.11. Pro-Tools S. StellarNet Inc.: Tampa, FL, USA, 2019.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.