Understanding the Impact of Noise on ECG Biometrics: A Comparative Theoretical and Experimental Analysis

,
,
,
and
1
CardioID Technologies, Parque Tecnológico de Óbidos, R. da Criatividade, 2510-216 Óbidos, Portugal
2
ISEL—Instituto Superior de Engenharia de Lisboa, Instituto Politécnico de Lisboa, Rua Conselheiro Emídio Navarro 1, 1959-007 Lisboa, Portugal
3
NOVA LINCS, NOVA School of Science and Technology, 2829-516 Caparica, Portugal
*
Author to whom correspondence should be addressed.

Abstract

Electrocardiogram (ECG)-based biometrics have emerged as a promising solution for continuous and intrinsic human identification; nevertheless, the robustness of these systems under realistic noise conditions remains a critical challenge for practical deployment. This work presents a theoretical and experimental analysis of how different noise types and levels affect ECG biometric recognition by comparing three methodological families: fiducial-based approaches using morphological features with traditional classifiers such as SVM and k-NN, non-fiducial methods based on signal compression and global descriptors, and Deep Learning models. Controlled distortions and additive noise injection into public ECG databases enable systematic quantification of feature degradation. Experimental validation is performed using the CardioWheel system, a real-world in-vehicle ECG acquisition platform, to evaluate performance under realistic motion and noise conditions. The methodological framework proposed for robustness evaluation and noise-aware training is inherently generic and can be extended to other biometric tasks subject to noise. Results show that different algorithmic families exhibit distinct resilience profiles under noise contamination and reveal a practical signal quality boundary for reliable ECG biometric recognition, with performance deteriorating under severe noise conditions. Noise-aware training improves robustness, particularly for Deep Learning and SVM-based classifiers, highlighting the trade-off between interpretability and robustness. By bridging theoretical analysis and applied experimentation, this work provides practical signal quality guidelines for real-world ECG biometric systems.

1. Introduction

Biometric technologies have gained increasing attention as secure and user-friendly alternatives to traditional authentication methods such as passwords or physical tokens [1]. Among the wide range of physiological signals explored in biometrics, the electrocardiogram (ECG) has emerged as a particularly appealing modality [2,3]. Unlike external traits such as face, iris, or fingerprints, the ECG reflects intrinsic electrical activity of the human heart, thus providing liveness assurance, continuous authentication capability, and resilience to spoofing [1,2,3,4].
Over the past two decades, diverse approaches for ECG-based biometric recognition have been proposed [2,5]. These methods can generally be classified into three main categories: (i) fiducial-based approaches, (ii) non-fiducial approaches, and (iii) Deep Learning-based approaches. Fiducial-based methods rely on detecting characteristic points of the ECG waveform (such as the P wave, the QRS complex, and the T wave), from which morphological and temporal features are extracted. Although these features are physiologically meaningful and interpretable, their extraction is reliant on successful fiducial point detection, making such approaches sensitive to noise and signal distortions [2,6].
Non-fiducial approaches, on the other hand, avoid explicit ECG signal delineation by feature extraction, typically leveraging transforms, correlation measures, or compression domains, enabling simpler and often more robust processing pipelines [7]. Deep Learning-based methods have recently shown strong potential, learning discriminative representations directly from raw or minimally processed ECG data [8]. Nevertheless, the robustness of ECG biometrics under realistic noise conditions remains an open challenge, as practical deployment scenarios are often characterized by severe and unpredictable noise contamination [2,9,10,11].
This is particularly true for off-the-person acquisition, which includes wearables and invisibles [12], devices embedded in everyday objects such as steering wheels, armrests, chairs or sanitary installations [13,14]. In these acquisition contexts, the ECG signal is often contaminated by multiple types of interference, including baseline wander (BW), motion artifacts (MA), electromyographic (EMG) noise, and power-line interference (PLI) [15]. These noise sources may significantly distort the ECG signal, thereby degrading feature stability and, consequently, recognition performance.
Despite the existing body of work on ECG-based biometrics, a systematic characterization of algorithmic robustness under controlled degraded noise conditions remains limited [2,16]. Existing studies often evaluate performance within specific acquisition setups or under particular noise conditions, frequently focusing on a single methodological paradigm or dataset [6,9]; therefore, comparative analyses across distinct algorithmic families, such as fiducial-based, non-fiducial compression-based, and Deep Learning approaches, remain relatively scarce. Furthermore, the interaction between structured noise modelling and noise-aware training strategies has not been consistently analyzed in a unified experimental framework. This work addresses these gaps by proposing a structured robustness evaluation methodology that combines controlled noise injection, cross-family comparison, and noise-aware training, complemented by validation under realistic acquisition conditions, through a combined theoretical and experimental analysis of the ECG biometric algorithmic paradigms previously described.
The methodological approach consists initially of controlled experiments performed on publicly available ECG databases, which are systematically contaminated with different types of synthetic noise at incremental signal-to-noise ratio (SNR) levels. In a second stage, the proposed methodology is validated using data acquired by the CardioWheel system, an in-vehicle ECG acquisition platform embedded in a steering wheel, enabling signal collection under realistic driving and motion conditions.
By correlating theoretically predicted degradation patterns with empirical observations, this work provides a structured characterization of the noise sensitivity and robustness profiles of different algorithmic families. In doing so, the work bridges the gap between ideal laboratory conditions and realistic acquisition scenarios, contributing both theoretical insight and practical guidance for the development of robust ECG-based biometric systems suitable for everyday environments.
The main contributions of this work can be summarized as follows:
1.
A systematic evaluation of ECG biometric performance under five representative noise types across a wide range of SNR conditions,
2.
The design and application of a structured ECG data-augmentation strategy based on controlled noise injection, for noise-aware training and fair cross-method comparison;
3.
A quantitative analysis of three fundamentally different algorithmic paradigms for ECG biometrics,
4.
An experimental validation of synthetic noise augmentation using real off-the-person ECG data acquired in a realistic automotive setting,
5.
The implementation of an open-source, reproducible framework for biosignal noise-injection and data-augmentation dataset generation, enabling public use and reproducibility. The implementation was developed in Python 3.11, using NumPy (1.26.4), SciPy (1.13.0), NeuroKit2 (0.2.12), and scikit-learn (1.5.0).
This document is organized as follows. Section 2 describes the datasets, noise modeling procedures, and the data-augmentation strategy used for training, as well as the experimental setup, including the evaluated biometric algorithms and performance metrics. Section 3 provides additional insight into the evaluation setup reports and summarizes the obtained results, including both noise-type and algorithm-wise performance analyses. Section 4 discusses the main findings and their implications for practical ECG biometric systems and outlines directions for future work. Finally, Section 5 concludes the paper. Extended numerical results and statistical validation tables are provided in the Supplementary Materials.

2. Materials and Methods

Early work on ECG-based biometrics relied primarily on wet electrodes and clinical-grade 12-lead systems under controlled medical settings [15,17]. Recent work, motivated by the need for unobtrusive, user-friendly devices for everyday use, has pivoted towards off-the-person and minimally invasive configurations such as invisibles [18,19]. In these scenarios, wet electrodes are replaced by dry electrodes, and acquisition is often performed using a single-lead configuration requiring only two or three points of contact [9,13,14].
Shen et al. [20] demonstrated ECG acquisition from both palms using two small metallic rod electrodes and discussed embedding this sensing configuration into everyday objects. Building upon this concept, CardioWheel [13] incorporates conductive leather into a vehicle steering wheel to capture ECG during normal driving; Pinto et al. [21] systematically analysed recordings from this configuration and established the viability of ECG-based biometrics in the automotive context, although a precise noise characterization was not encompassed in this work; subsequent contributions proposed pervasive identity recognition systems by integrating textile electrodes into keyboard and chair armrests [19,22], and other work has explored polymeric electrodes integrated into sanitary hardware for effective ECG acquisition aligned with the invisibles concept [18].

2.1. ECG Acquisition and Databases

Motivated by these emerging use cases, this study relies on three complementary sources of ECG data:
  • Public ECG databases: The MIT-BIH Arrhythmia (MIT-BIH-A) [23,24,25] and ECG-ID [24,26,27] databases were used as sources of clean, annotated ECG recordings acquired under clinical conditions. These datasets provide a reliable baseline for algorithm evaluation and enable controlled synthetic noise injection;
  • Noise-only recordings: The MIT-BIH Noise Stress Test Database (MIT-BIH-NS) [24,28] was used to obtain realistic baseline wander (BW), electromyographic (EMG) noise, and motion artifact (MA) recordings. These were obtained from active volunteers, with electrode placement arranged so that underlying ECG activity was not visible;
  • Real-world data (CardioWheel): Experimental data was collected using the CardioWheel system (CW), a single-lead steering-wheel-embedded ECG acquisition platform developed for in-vehicle driver monitoring. The system integrates dry electrodes and an analog front-end circuitry optimized for motion-intensive conditions [13]. Data were collected during simulated driving sessions under realistic, non-stationary conditions, providing a comparatively controlled yet realistic setting. Unlike the previously presented datasets, these recordings capture a broad range of physiological and environmental variability, including motion artifacts, grip changes, fluctuations in skin impedance, driving maneuvers, and road conditions. These factors create a more challenging and representative evaluation scenario for off-the-person ECG acquisition.
Table 1 summarizes the main characteristics of the datasets considered in this study. The MIT-BIH-A database comprises 48 ECG recordings with an average duration of approximately 30 min. The ECG-ID database contains recordings from 90 subjects with an average length of about 20 s; however, only 41 subjects were retained, as a minimum of three recordings per subject was required to construct disjoint training, validation, and testing sets. Recordings were assigned to each set such that no record segment was shared across sets, thus preventing sample-level leakage between model training and performance evaluation. Finally, data from 31 test subjects was collected using the CardioWheel system, with a minimum recording duration of 60 s per subject. Figure 1 illustrates representative off-the-person acquisition scenarios.
Table 1. Overview of the ECG datasets used in this study.
Figure 1. Examples of CardioWheel ECG acquisition applications. (a) Arm-rest setup. (b) Steering-wheel demonstrator setup.

2.2. Noise Models and Simulation Framework

To assess the robustness of ECG-based biometric systems, five representative types of noise commonly observed in real-world acquisition scenarios were considered:
  • Baseline wander (BW): low-frequency drifts, typically below 0.5 Hz, mainly caused by respiration or slow body and electrode motion, typically modeled as slowly varying polynomials or sinusoidal components.
  • Electromyographic (EMG) noise: high-frequency interference (20–100 Hz) originating from muscle activity near the electrodes, with a burst-like appearance.
  • Motion Artifacts (MA): derived from changes in electrode contact with the skin through phenomena such as subject movement, cable tugging or poor adhesion. Manifests as abrupt baseline excursions, typically non-stationary and sometimes large amplitude.
  • Powerline interference (PLI): narrow-band sinusoidal components at 50 Hz (or 60 Hz depending on the region) due to electrical coupling from surrounding systems.
  • White Noise: random noise with a flat frequency spectrum, mainly arising from electronic circuitry thermal noise and quantization noise introduced during analog-to-digital conversion.
For BW, EMG, and MA, real noise-only signals from the MIT-BIH-NS were used. PLI was synthetically generated as a sinusoidal signal at 50 Hz, and white noise was modeled as zero-mean additive white Gaussian noise (AWGN). For all cases, the power of the noise and the signal were computed and then superimposed to achieve the desired SNR value, ranging from −50 dB to +30 dB. This process enabled a systematic and reproducible evaluation of algorithmic behavior under varying levels of signal degradation. The characterization of each noise type and its expected effects forms the basis for the interpretation of all subsequent experimental results. Figure 2 illustrates representative ECG segments contaminated with different noise types at an SNR of 0 dB.
Figure 2. ECG signals obtained from MIT-BIH-A record # 103, illustrating the original signal and its corresponding versions contaminated with different types of noise. Subfigure (a) shows the original signal, while subfigures (b–f) present versions with synthetically added noise at an SNR of 0 dB: (b) AWGN, (c) BW, (d) EMG, (e) MA, and (f) PLI.
To achieve systematic and reproducible SNR-based noise injection suitable for all noise types detailed in this study, the following approach was conducted: the noise samples obtained from the sources specified in Section 2.1 are matched to the length of each ECG template, detrended, centered and scaled so that the resulting noisy signal achieves a target SNR specified in dB.
Let s [ n ] and r [ n ] , n = 1 , … , N , denote a clean ECG segment and a noise sample aligned to the same length. SNR can be calculated as
SNR dB = 10 log 10 P s P n , SNR lin = 10 SNR dB / 10 .
where the (linear) signal power is
P s = 1 N ∑ n = 1 N s [ n ] 2 .
The desired noise power, P r , desired , and the original noise power, P r , 0 , from which the scaling factor that produces the desired SNR can be calculated, are
P r , desired = P s SNR lin , P r , 0 = 1 N ∑ n = 1 N r [ n ] 2 , β = P r , desired P r , 0 .
Finally, the noisy signal, x [ n ] , is formed as
x [ n ] = s [ n ] + β r [ n ] .
Figure 3 shows the effect of varying SNR for a given noise type (PLI), showing the original raw signal, and the contamination obtained with SNR = 10 dB, 0 dB and −10 dB, where the the typical QRST complexes become more difficult to identify as SNR decreases.
Figure 3. ECG signals obtained from MIT-BIH-A record #. 103, illustrating the original signal and its corresponding versions contaminated with PLI. Subfigure (a) shows the original signal, while subfigures (b–d) present versions with synthetically added noise at an SNR of (b) −10 dB, (c) 0 dB and (d) 10 dB.

2.3. Biometric Approaches

Figure 4 presents a block diagram of a generic biometric system, similar to that described in [2]. It is necessary that it starts with the signal acquisition, be it facial or retinal images, DNA sequences, or, in this case, an ECG signal [29,30].
Figure 4. Diagram of a standard biometric system. Note that in authentication mode, the decision block may have a third input, corresponding to the claimed identity.
In regards to ECG-based biometrics, pre-processing namely entails segmentation of the signal into separate heartbeats, time and amplitude normalization, and outlier detection [2]. After the feature extraction process, the data concerning individual heartbeats is turned into a ‘template’, each representing the information relevant to the recognition process.
Biometric systems may operate in three distinct modes: enrollment, authentication, and identification. Enrollment refers to the process by which biometric templates are associated with a given subject identity and stored for subsequent recognition. In authentication mode, a claimed identity is provided to the system together with incoming biometric data, and a binary decision (accept or reject) is produced based on a comparison with the stored templates of the claimed subject. In identification mode, the system compares the incoming templates against all enrolled identities and determines the most likely match, if any.
This study exclusively considers the identification scenario, addressing closed-set identification in which each query ECG segment is matched against the complete set of enrolled subject templates, reflecting a closed-set identification task.

2.3.1. Fiducial-Based Approaches

Fiducial-based methods rely on the detection of characteristic reference points in the ECG waveform, such as the P, QRS, and T complexes. From these fiducial points, morphological and temporal features are extracted, including peak amplitudes, interval durations, and waveform areas [2]. These features are subsequently used to train classical pattern recognition algorithms, such as k-nearest neighbors (k-NN) and margin-based classifiers, notably Support Vector Machines (SVMs), which aim to maximize inter-subject separation in the resulting feature space. These algorithms were selected due to their widespread adoption in the ECG biometric literature and their established effectiveness in handling structured feature representations derived from fiducial descriptors. In this work, k-NN was implemented using the Euclidean distance metric, with the number of neighbors determined via cross-validation to balance bias and variance. SVM models employed a radial basis function (RBF) kernel, selected for its capacity to model nonlinear decision boundaries commonly observed in biometric feature spaces. Kernel and regularization parameters were optimized through grid search on the validation subset to ensure consistent and fair performance comparisons. In such approaches, the ECG signal is typically segmented into individual heartbeats or short windows containing a fixed number of beats, and features are computed for each segment.

2.3.2. Non-Fiducial/Compression-Based Approaches

Non-fiducial methods eliminate the dependency on accurate heartbeat segmentation or delineation by treating the ECG as a global pattern or symbolic sequence, from which discriminative information is derived directly, with reduced preprocessing and feature engineering effort [6,16]. Compression-based non-fiducial methods go a step further by leveraging information-theoretic principles to quantify the similarity between ECG sequences. In particular, the Ziv–Merhav Cross Parsing (ZMCP) algorithm provides an empirical method to estimate the relative entropy between sequences, allowing the construction of universal dissimilarity measures that require no model of the underlying signal [16,31]. This method is based on the incremental Lempel–Ziv (LZ) parsing algorithm [32] and on a variation thereof, known as cross-parsing. Combining these two algorithms, Ziv and Merhav [31] proposed an estimator of the relative entropy between two ergodic sources producing the sequences z and x.
These dissimilarity measures, when applied to ECG-based biometric recognition, achieve competitive or superior performance compared to conventional feature-based systems while maintaining conceptual simplicity, universality, and resilience to signal variability [7,33]. This procedure is applied to mapping ECG signals into a feature space using universal dissimilarity measures. In this space, classical classifiers such as k-NN or SVM can then be used. The experimental evaluation on the ECG-based identification task demonstrates that ZMCP can outperform more complex approaches in specific scenarios, despite its conceptual simplicity [7,33].

2.3.3. Deep Learning Approaches

Deep Learning approaches were also explored, as these represent a growing and promising trend in ECG biometrics [2,34]. The main advantage of these approaches is the versatility of neural networks. At its core, a Deep Neural Network (DNN) works in a non-fiducial manner to learn discriminative representations from whatever signals it is trained on, foregoing explicit feature extraction. However, while these input signals can be raw or minimally processed, they can also first be treated with fiducial approaches, such as segmentation, to attempt to reduce irrelevant data or possible connections, therefore entering a more hybrid approach. It is even possible to use a DNN as the classifier in a fiducial-based approach, though they do not present any meaningful advantage over traditional classification methods in that context.
In this work we follow the architecture described in ref. [35], a Residual Depthwise Separable Convolutional Neural Network (RDSCNN).
The architecture of the network is presented in Table 2, including each layer’s output shape and number of parameters, as well as each convolution layer’s parameters (number of filters, kernel size, and stride). Additionally, all convolution layers use “same” padding (meaning there is even padding at the edges of the input such that, for a stride of 1, the input and output have the same shape) and all max pooling layers use a pool size of 4, where C represents the number of classes in the problem, i.e., the number of subjects for biometric recognition. Therefore, when using the MIT-BIH-A database, which includes 48 subjects, the final layer will have 3120 parameters and the CNN will have 30,752 total parameters.
Table 2. CNN layer architecture.
The resulting network was trained using the Nadam optimizer and categorical cross-entropy loss function. At every epoch, the model was stored if and only if the resulting validation loss was lower than any previous epoch; this way, if the model begins overfitting, validation loss will begin rising, and the overfitted weights will not be stored.

2.4. Methodological Framework

A standardized ECG pre-processing and heartbeat template extraction pipeline was applied to all signal segments prior to classification. Segmentation was performed using ECG signal analysis and R-peak detection. From each ECG segment, ten individual heartbeat templates were extracted per test subject, spanning a window of 200 ms before and 400 ms after each detected R-peak, thereby ensuring a controlled and balanced representation of local cardiac morphology.
To guarantee dimensional consistency across all classifiers, each extracted heartbeat template was resampled to a fixed length of 256 samples, ensuring that every template is represented by an equal-length feature vector, independent of the original heart rate, inter-beat variability and sampling frequency. This process is depicted in Figure 5. The resulting resampled templates were then organized into structured data matrices, where each row corresponds to a single heartbeat template and each column represents a normalized temporal sample point, with an additional metadata column containing a unique test-subject identifier for traceability and consistency purposes. This standardized template representation serves as the common input space for all evaluated classifiers across the subsequent experimental stages.
Figure 5. (a) Individual ECG heartbeat templates for record # 16 of ECG-ID dataset, overlaid to illustrate interbeat variability. (b) Mean ECG template with the corresponding ±1 standard deviation envelope, for the templates shown in (a).
To achieve structured data-augmentation, each original ECG recording from the selected databases was synthetically contaminated with multiple noise types at several SNR levels, as formally defined in Section 2.2. Each noise type was applied across a predefined range of SNR values, thus yielding a structured augmented dataset in the form of an m × n matrix per original recording, where m denotes the number of SNR conditions and n the number of noise types, as illustrated in Figure 6. All processed templates were subsequently aggregated into unified datasets and exported in comma-separated value format files for classification. Each noise-type-SNR-dataset combination was stored in an independent CSV file, ensuring a clear and structured organization of the augmented data. This pipeline was automated, thus guaranteeing reproducible ECG segmentation, dimensional standardization, and scalable dataset generation across all noise conditions, SNR levels, and databases considered in this study (the open-source framework for biosignal noise-injection and data-augmentation dataset generation is available at the following repository: ECG Noise Injection Preprocessing Pipeline (https://github.com/DavidEMVelez/ECG-Noise-Injection-Preprocessing-Pipeline, accessed on 31 May 2025)).
Figure 6. Illustration of the data-augmentation procedure used in this study. An original ECG recording taken as the source signal is systematically contaminated with multiple noise types across a range of SNR levels. This process expands each original recording into an m × n matrix of augmented samples, where m denotes the number of SNR conditions and n the number of noise types, resulting in a structured augmented ECG dataset with controlled noise characteristics.

3. Experimental Setup and Results

This section presents a comprehensive evaluation of the biometric algorithms considered in this study. Table 3 and Table 4 present classification accuracy for the four evaluated methods across the considered datasets. As a baseline, all methods were initially trained and tested exclusively using the original, uncontaminated ECG recordings from the selected datasets, with 10 heartbeat templates used for training and an additional 10 templates for testing.
Table 3. Classification accuracy (%) obtained using five-fold cross-validation on the MIT-BIH-A dataset under clean training conditions. Mean accuracy, standard deviation (STD), and the corresponding 95% confidence interval (CI) are reported across folds.
Table 4. Accuracy (%) achieved by each biometric model on the ECG-ID datasets.
Regarding biometric model evaluation, a four-stage experimental protocol was adopted to progressively assess baseline performance, intrinsic noise robustness, and practical applicability. Performance was primarily quantified using classification accuracy, reported as the mean accuracy across 5-fold cross-validation, together with the corresponding standard deviation (SD) and 95% confidence interval (CI) when applicable. In the first stage, all biometric models were trained and evaluated exclusively using the original, uncontaminated recordings from the reference datasets, establishing a baseline performance reference for comparison across methods. Due to the limited number and short duration of recordings available per subject in ECG-ID, the statistical evaluation based on 5-fold cross-validation was performed exclusively using the MIT-BIH-A database. In the second stage, the same models were evaluated using synthetically contaminated ECG signals generated under controlled signal-to-noise ratio (SNR) conditions. This configuration isolates the effect of noise and enables a direct assessment of each algorithm’s intrinsic robustness to signal degradation. Accuracy degradation profiles were derived as a function of SNR for each noise type and model, providing a structured representation of performance trends across noise conditions and severity levels. In the third stage, noise-aware training was introduced through a structured data-augmentation strategy. The models were retrained using a combination of clean and synthetically contaminated ECG data drawn from the augmented datasets, and subsequently re-evaluated in order to quantify the contribution of augmentation to classification performance and robustness under noisy conditions. Finally, the proposed framework was validated using ECG recordings acquired under off-the-person conditions with the CardioWheel system. This final stage bridges controlled synthetic experiments with real-world acquisition scenarios, enabling an assessment of the practical applicability of the proposed methodology in realistic operational environments.
Collectively, these results indicate that learning-based approaches achieved the strongest overall baseline performance across both datasets, with Deep Learning attaining the best result on ECG-ID and k-NN showing the most stable behavior across both databases, while ZMCP achieves the highest accuracy on MIT-BIH-A.

3.1. Testing with Noise-Contaminated ECG Data

In this evaluation stage, all models were trained exclusively on the original, uncontaminated ECG recordings from the selected datasets, as in the previous experiments. Testing was performed on synthetically contaminated signals with progressively decreasing SNR levels. This setup isolates the effect of noise at test time and enables a direct assessment of the intrinsic noise sensitivity of each algorithmic approach.
The results of the compression-based algorithm, shown in Figure 7, indicate that as SNR decreases toward 10 dB, a sharp decrease in accuracy is observed for AWGN, BW, MA and EMG noise sources. PLI clearly exhibits a different behaviour, sustaining high accuracy at very low SNR values, only significantly decreasing in accuracy by an SNR of −10 dB onward.
Figure 7. Results for ZMCP. (a) Results for MIT-BIH-A dataset. (b) Results for ECG-ID dataset.
The k-NN results, shown in Figure 8, achieve maximum accuracies of approximately 85–95% at high SNR values for both datasets. A sharp accuracy drop-off is observed as SNR decreases below approximately 0 to −5 dB for AWGN, BW, MA, and EMG, with accuracy rapidly approaching near-zero levels at strongly negative SNR. In contrast, PLI sustains comparatively high accuracy across a broader SNR range, with a noticeable degradation occurring only below −10 dB.
Figure 8. Results for k-NN. (a) Results for MIT-BIH-A dataset. (b) Results for ECG-ID dataset.
The SVM results, shown in Figure 9, reach accuracies exceeding 90% at high SNR values under AWGN, BW, MA, and EMG for both datasets. A significant performance drop is observed as SNR decreases below approximately −5 dB, where accuracy rapidly deteriorates toward low values. As with the remaining classifiers, PLI shows a distinctly different trend, maintaining relatively high accuracy at low SNR and only exhibiting a marked decline below approximately −10 dB.
Figure 9. Results for SVM. (a) Results for MIT-BIH-A dataset. (b) Results for ECG-ID dataset.
The deep learning results, shown in Figure 10, achieve maximum accuracies of approximately 90–95% at favourable SNR values for AWGN, BW, MA, and EMG. A notable drop-off in accuracy is observed as SNR decreases below approximately 5–10 dB, after which performance degrades rapidly at lower SNR levels. In contrast, PLI again demonstrates an early high-accuracy regime, with substantial degradation occurring only at strongly negative SNR values, typically below −10 dB.
Figure 10. Results for deep learning. (a) Results for MIT-BIH-A dataset. (b) Results for ECG-ID dataset.
To enable a direct comparison of the intrinsic robustness of each algorithm to signal degradation, testing was conducted using a single noise type at an SNR of 0 dB, corresponding to a condition in which signal and noise power are equal. The resulting classification accuracies are reported in Table 5 and Table 6 and reveal a strong dependence on both noise type and algorithmic family.
Table 5. Classification accuracy (%) under different test data contamination conditions for the MIT-BIH-A database at an SNR of 0 dB. Values represent mean accuracy across 5 folds with the corresponding 95% confidence interval. Detailed data is provided in the Supplementary Material.
Table 6. Classification accuracy (%) under different test data contamination conditions for the ECG-ID databases, at an SNR of 0 dB.
Across both datasets, a consistent pattern emerges regarding the impact of different noise types on biometric performance when models are trained on clean data and evaluated on contaminated signals. Broadband and nonstationary disturbances, namely AWGN, BW, EMG, and MA, produce substantial degradation in classification accuracy at 0 dB SNR across all evaluated algorithms. The most disruptive noise type varies by classifier and dataset, though broadband and non-stationary disturbances such as AWGN, EMG and motion artifacts consistently produce the largest degradations. PLI consistently results in the highest accuracy levels among the tested noise types, suggesting that its narrowband spectral structure is comparatively less detrimental to the discriminative information contained in the ECG signal.
Classical classifiers such as k-NN and SVM tend to exhibit higher robustness under AWGN and BW contamination when compared with the compression-based ZMCP method, while learning-based approaches maintain competitive performance under PLI conditions. Overall, these observations indicate that the robustness of ECG biometric systems is influenced not only by noise intensity but also by the spectral and temporal characteristics of the disturbance.
These results establish a baseline characterization of algorithmic sensitivity to different noise mechanisms when models are trained exclusively on clean data, motivating the introduction of noise-aware training strategies evaluated in the following section.

3.2. Training with ECG Data-Augmentation

In contrast to the previous experiments, where model training was performed exclusively using the original ECG data, this section evaluates classification performance when training incorporates synthetically contaminated ECG signals, thus quantifying how noise-aware training alters the accuracy–SNR relationship observed in the baseline robustness analysis. Following the structured ECG data-augmentation strategy described in Section 2.4 and the performance degradation profiles from Section 3.1, the training set was expanded by including an additional 10 heartbeat templates contaminated at an SNR of 5 dB for each noise type individually. Model evaluation was then conducted using test ECG signals contaminated at an SNR of 0 dB, corresponding to a challenging noise condition.
Table 7 presents the classification performance results for test data contaminated with EMG, as a percentage change from baseline presented in Table 5 and Table 6. It shows that training with noise-augmented datasets of any of the noise types considered in this test improves classification performance across both datasets and all classifiers when ECG data is contaminated with EMG noise.
Table 7. Percentage change in classification performance for test data contaminated with EMG at 0 dB SNR. Negative values indicate a decrease in performance relative to the clean baseline from the values presented in Table 5. Green cells indicate performance improvements relative to the baseline.
For the MIT-BIH-A, all methods exhibit positive performance gains for every training configuration, with the most pronounced improvements observed for Deep Learning when trained with EMG and BW-augmented data (gains of +25.0% and +16.7% were observed, respectively). For SVM, the largest gains on MIT-BIH-A are observed when training with MA and EMG-contaminated data (+7.9% and +6.9%, respectively). k-NN presents very uniform but comparatively smaller improvement across all types, with a maximum of +6.3% gain. Regarding the ECG-ID database, a positive trend is sustained, with significant gains for k-NN and Deep Learning when trained with BW, EMG, and MA noise (up to +17.1% gain). Overall, only a limited number of zero-valued deltas occur, reflecting cases in which augmentation neither improves nor degrades performance. No negative impact is observed for the presented configuration, highlighting consistent improvement under EMG interference across all algorithmic families. The full results are detailed in the Supplementary Material, and the aggregated results presented in Table 8 denote noise-type dependency of data-augmented training on overall performance.
Table 8. Accuracy gain (%) of data-augmented training, corresponding to the arithmetic mean performance variation across all classifiers and databases, detailed in the Supplementary Material.
AWGN produces the largest average improvement, indicating that beneficial impact is strong but with significant variability. AWGN and BW present mean gains above 7%, while EMG also yields a positive mean improvement of approximately 6%, with EMG presenting the most stable behavior, confirming that exposure to noise during training effectively improves robustness under contaminated testing conditions. In contrast, PLI augmentation shows a slight negative mean effect.
When the results are grouped by algorithm in Table 8, k-NN, SVM, and Deep Learning exhibit overall positive mean accuracy gains, with Deep Learning achieving the highest average improvement, while ZMCP exhibits modest overall mean improvement, accompanied by moderate dispersion. For the machine learning-based methods, Deep Learning achieves the highest average accuracy gain, as well as the largest standard deviation, evidencing both the strongest overall improvement and the widest spread of performance variations across different noise and database conditions. k-NN shows a consistent positive mean gain with comparatively lower dispersion, whereas SVM presents a moderate positive mean accompanied by the highest variability, indicating less uniform behavior across conditions.
Jointly, the results in the Supplementary Material and Table 7, Table 8, Table 9 and Table 10 indicate an overall positive effect of data-augmented training on classification performance across different noise and database conditions.
Table 9. Classification accuracy (%) under different test data contamination conditions for the MIT-BIH-A database at an SNR of 0 dB when models are trained with noise-contaminated data. Values represent mean accuracy across five folds with the corresponding 95% confidence interval.
Table 10. Performance improvement ( Δ accuracy in %) obtained with noise-aware training relative to clean-only training for the MIT-BIH-A dataset, caculated from Table 5 and Table 9. Values are computed from the results of the five-fold cross-validation procedure. Positive values indicate accuracy gains when models are trained with noise-contaminated samples. The last column reports the average improvement per algorithm, while the last row summarizes the average improvement per noise type. For conciseness, only the mean accuracy improvement is shown; the corresponding standard deviations and 95% confidence intervals are reported in Table 5 and Table 9, and in the Supplementary Material.
In addition to the 5-fold performance and confidence intervals, a statistical significance analysis was conducted to assess whether the observed improvements obtained with noise-aware training were consistent across experiments and statistically significant. For this purpose, a paired Wilcoxon signed-rank test was applied to compare classification accuracies obtained with clean-only training to noise-aware training.
Rather than evaluating each noise condition independently, 5-fold results were aggregated across all noise types, yielding n = 25 paired observations per algorithm (e.g., 5-fold cross-validation across five noise types), thus increasing the statistical power of the test while preserving the paired structure of the experiments. The Wilcoxon signed-rank test was selected due to its non-parametric nature, which does not assume normality of the underlying distributions and is therefore appropriate for small-sample performance comparisons commonly encountered in biometric evaluation studies. The results of this test are presented in Table 11.
Table 11. Wilcoxon signed-rank test results comparing classification accuracy obtained with clean-only training and noise-aware training. Fold-wise results were pooled across all noise types, yielding n = 25 paired observations per algorithm. Δ Acc denotes the accuracy improvement (dirty minus clean).
The results presented in Table 11 indicate that noise-aware training leads to statistically significant performance improvements for the Deep Learning, SVM, and ZMCP approaches. In particular, the Deep Learning model exhibits the largest average accuracy gain ( 17.67 % ), reflecting its strong capacity to benefit from exposure to noisy training conditions. Similarly, the SVM classifier demonstrates a consistent improvement across folds and noise types, resulting in a highly significant test outcome.
The compression-based ZMCP method also shows a statistically significant improvement, although with a more moderate median gain. This suggests that, despite its simplicity and model-free nature, the method can still benefit from training exposure to degraded signal conditions. In contrast, the k-NN classifier shows only a marginal average improvement without statistical significance. This behaviour is consistent with the local decision mechanism of k-NN, which is more sensitive to sample-level variability and less capable of learning generalized noise-invariant representations. The statistical analysis therefore supports the trends observed in the classification accuracy tables.

3.3. Testing with Real-World CardioWheel Data

To evaluate practical feasibility, experiments were conducted using real-world data acquired with the CardioWheel system. Testing on this dataset allows assessment not only of the baseline performance of the biometric algorithms under naturalistic conditions, but also their robustness to noise and their sensitivity to intra-subject variability.
Figure 11 depicts a recording from CardioWheel device. Compared to ECG-ID and MIT-BIH-A, these signals exhibit a visibly higher level of noise contamination, due to the use of dry electrodes, and the motion of the user during acquisition.
Figure 11. ECG recording taken from test subject #11 with CardioWheel using a conductive leather steering wheel cover. Subfigure (a) shows the original signal, while subfigure (b) presents a denoised version of the signal, with a measured SNR improvement of 9 dB.
To enable a direct assessment and comparison of the datasets considered in this study, ECG acquired by CardioWheel was considered a contaminated ECG signal. To obtain a clean version, a standard ECG cleaning procedure was designed to suppress baseline wander and powerline interference, consisting of a fifth-order high-pass Butterworth filter with a cutoff frequency of f High − Pass = 0.5 Hz . The removed component was treated as noise and the filtered output as the clean signal. Signal quality was quantified prior to classification by estimating the SNR, as per Equation (1). For the CardioWheel dataset, this procedure resulted in an average SNR improvement of approximately 9.1 dB. Signal quality was further characterized using spectral-based Signal Quality Indices (SQIs), namely the power-based SQI (pSQI) and the kurtosis-based SQI (kSQI) [36,37]. The pSQI quantifies the ratio of power spectral density of ECG signal energy concentrated in the QRS-dominant frequency band centered at 10 Hz and is 10 Hz in width, relative to the total ECG bandwidth of 5 Hz to 40 Hz, providing an indicator of spectral consistency and sensitivity to broadband noise [36]. The kSQI measures the kurtosis of the ECG amplitude distribution, calculated by measuring the fourth standardized moment of the signal, reflecting the sharpness and prominence of QRS complexes and thus capturing morphological degradation due to motion artifacts or muscle noise. Following the heuristic SQI-based quality assessment framework proposed by Zhao and Zhang [36], ECG signal quality was categorized using rule-based thresholds applied to pSQI and kSQI. The resulting decision matrix, summarized in Equation (5), provides interpretable discrete quality classes for ECG signal quality.
ECG quality = pSQI : optimal , 0.5 ≤ pSQI ≤ 0.8 , suspicious , 0.4 ≤ pSQI < 0.5 , unqualified , pSQI < 0.4 or pSQI > 0.8 , kSQI : optimal , kSQI > 5 , unqualified , kSQI ≤ 5 .
Table 12 summarizes the SNR and SQI metrics obtained for the considered datasets, highlighting clear differences in signal quality across acquisition setups and preprocessing conditions. It should be noted that, with the exception of the CW-Denoised case, as previously stated, the ECG signals used in this analysis were not subjected to additional filtering or processing beyond basic detrending. Consequently, the reported pSQI values are lower than those typically reported in studies employing aggressively filtered or ECG windowing, providing a conservative and realistic assessment of signal quality under unprocessed conditions. As expected, the MIT-BIH dataset exhibits the highest intrinsic signal quality, reflected by its superior SNR and kSQI values, which indicate clinical-grade recordings with well-defined QRS complexes and low noise contamination. The ECG-ID dataset presents moderate SNR together with slightly lower pSQI and kSQI values, consistent with its ambulatory acquisition conditions and increased susceptibility to noise, while still preserving acceptable morphological integrity. The original CardioWheel (CW) recordings show the lowest SNR and pSQI values, confirming the challenging nature of off-the-person ECG acquisition using non-adhesive electrodes. After denoising, the CW signals exhibit a substantial improvement in SNR. A modest increase in pSQI is observed, accompanied by a small reduction in kSQI, suggesting that while denoising effectively enhances SNR, it may also smooth ECG morphology by reducing the impulsiveness of the QRS complexes, resulting in energy-based (pSQI) and morphology-based (kSQI) SQIs responding in opposite directions to denoising.
Table 12. SNR and SQI metrics for the data sets.
Based on the metrics reported in Table 12, the CardioWheel (CW) dataset was identified as the most heavily noise-contaminated, reflecting its intrinsic electrode configuration and off-the-person acquisition conditions. Accordingly, a dedicated evaluation protocol was defined in which the original and unfiltered CW recordings were treated as the noisy condition, while the filtered signals were considered their denoised counterparts for subsequent analysis. Table 13 details the classification accuracy obtained on the CW dataset under different training conditions, and complements the baseline results presented in Table 3 and Table 4. These results reflect the impact of training data—original, denoised, and combined—on classification performance under realistic off-the-person ECG conditions.
Table 13. Classification accuracy (%) on the CW dataset for different training conditions: trained on original signals, denoised signals, and a combination of original and denoised data.
To quantify intra-subject morphological variability in the CW dataset ECG signals, an average template for each subject was computed by taking the mean across all the subject’s available segments, yielding a single representative waveform per user. The similarity between each individual template and the subject reference was quantified by computing the Euclidean distance. This procedure was performed for both the original (noisy) and the denoised versions of the dataset. By comparing the resulting distance distributions, it was possible to gain additional insight into the impact of noise on inter-subject variability and waveform consistency. Figure 12 shows the histograms of the obtained distributions.
Figure 12. Comparison of intra-user template distances using Euclidean distance.
In the noisy condition, the distance values are more widely dispersed, spanning a larger interval and exhibiting a heavier right tail, which indicates greater intra-user variability and the presence of noisy templates with substantially different morphological characteristics. This spread is consistent with the addition of noise components that distort the original ECG waveform patterns.
Figure 12 compares the distribution of Euclidean distances between individual templates and the subject reference template for noisy and denoised ECG data. Table 14 summarizes the corresponding statistical characterization of the Euclidean distance distributions for the different conditions.
Table 14. Statistical characterization of Euclidean distances between individual ECG templates and subject reference templates for the CardioWheel dataset.
In the noisy condition, the distance values are more widely dispersed, spanning a larger interval and exhibiting a heavier right tail, which indicates greater intra-user variability and the presence of outlier templates with substantially different morphological characteristics. This spread is consistent with the addition of noise components that distort the original ECG waveform patterns.
In contrast, the denoised condition shows a visibly more compact distribution, with distances concentrating in a narrower range and a reduced occurrence of extreme values. This contraction indicates that the denoising process successfully suppressed signal artifacts and enhanced the common morphological structure across users. As a consequence, individual templates become more similar to the subject reference template, resulting in reduced distances.

4. Discussion

The results of this study confirm that noise is a dominant limiting factor in ECG-based biometric recognition, regardless of the algorithmic approach employed, with particularly pronounced impact in off-the-person acquisition scenarios, where disturbances are unavoidable.

4.1. Impact of Noise on Tested Algorithmic Families

Across all datasets and algorithmic families, from a practical perspective, a clear performance boundary emerges with increasing noise severity. When SNR falls below approximately − 5 dB, classification accuracy collapses for all evaluated methods, indicating a practical lower bound for reliable ECG-based biometric recognition under broadband and nonstationary noise conditions. As described in Section 2.2, this behavior is expected when noise power dominates the ECG morphology, leading to severe feature corruption and loss of inter-subject discriminability. In practice, this threshold should be interpreted as an approximate operational boundary under the specific experimental conditions considered, rather than as a universal limit, since real-world ECG quality depends on electrode configuration, acquisition hardware, and user behavior.
Although SNR itself is not directly measurable in real-time operational settings, surrogate quality indicators such as pSQI and kSQI could potentially serve as proxy metrics for estimating signal degradation. The observed relationship between denoising, SNR variation, and SQI behavior indicates that quality indices may be incorporated into a real-time signal validation stage, where segments falling below predefined quality thresholds are rejected prior to authentication or identification. Such an approach could reduce false decisions under severely degraded acquisition conditions and represents a promising direction for integrating signal quality monitoring into practical ECG biometric systems.
Powerline interference constitutes a notable exception to this trend. Owing to its narrowband and highly structured spectral characteristics, several algorithms retain acceptable performance even at very low SNR levels. This observation highlights that biometric robustness is not governed solely by noise intensity, but is strongly influenced by the spectral and temporal structure of the contaminating noise.
Compression-based methods avoid explicit fiducial extraction and therefore behave differently under noise, but remain sensitive to large morphological distortions. In particular, under AWGN and EMG noise, signal statistics become substantially altered, leading to reduced parsing consistency and inter-subject separability.
Fiducial-based methods relying on accurate landmark detection are particularly sensitive to noise that disrupts reliable R-peak detection and the QRS complex alignment. Even moderate distortions resulted in R-peak misalignment and unstable feature extraction, producing abrupt performance degradation, consistent with the vulnerability of fiducial detection.
Deep Learning models showed the strongest baseline robustness among all evaluated approaches. Convolutional architectures were able to absorb moderate signal variability and preserve discriminative features under noise contamination more effectively than classical methods. However, when trained exclusively on clean data, even deep models experienced substantial performance degradation under severe noise, indicating that robustness does not emerge automatically from model complexity alone.

4.2. Effectiveness of Noise-Augmented Training

A central outcome of this work is the overall benefit of noise-augmented training for learning-based and margin-based methods, although the compression-based ZMCP approach does not benefit uniformly. As detailed in Section 2.4, exposing models to controlled perturbations during training enabled the learning of more noise-invariant representations, significantly improving generalization under degraded test conditions.
The largest gains were observed for AWGN, with BW and EMG also yielding positive mean improvements; this suggests that augmentation is particularly effective for noise sources that overlap spectrally with ECG morphology that cannot be easily suppressed through filtering. MA augmentation also led to performance improvements, albeit of smaller magnitude, reflecting their more slowly varying impact on signal morphology.
Deep Learning models demonstrated strong robustness once exposed to noise-augmented training. Their high representational capacity allowed the learning of robust hierarchical features once sufficient variability had been introduced during training. Margin-based classifiers, such as SVMs, also showed strong improvements, indicating that expanded training distributions improve class separation. In contrast, k-NN benefited less consistently, reflecting its sensitivity to local neighborhood structure and the absence of an explicit learning phase.
In contrast to learning-based classifiers, the compression-based ZMCP approach exhibited limited or negative gains under noise-augmented training. This behavior can be attributed to the probabilistic nature of the relative entropy estimation underlying the method. ZMCP is reliant on cross-parsing statistics to estimate dissimilarity between symbolic sequences, implicitly assuming that reference sequences represent stable ergodic sources. Introducing synthetic noise during training increases intra-class variability and alters the empirical parsing structure, effectively broadening the estimated source distribution. As a result, the contrast between inter-subject and intra-subject dissimilarities may be reduced, diminishing separability. Unlike discriminative models that can learn invariant representations, compression-based methods may become less distinctive when the statistical richness of the reference sequences is degraded by stochastic perturbations.

4.3. Practical Implications for Real-World Off-the-Person ECG Biometric Systems

The CW dataset provided a realistic validation scenario, characterized by contact instability, motion artifacts, and increased intra-subject variability. As anticipated from the signal quality analysis, these recordings exhibited substantially lower SNR and poorer SQI metrics compared with clinical datasets. Models trained solely on clean data underperformed, particularly for non-learning-based methods under these conditions, underscoring the gap between laboratory benchmarks and operational environments.
In contrast, models trained with mixed training conditions achieved improved performance on CardioWheel recordings. Although synthetic noise cannot fully reproduce the complexity of real-world motion artifacts, the observed gains demonstrate that data augmentation constitutes an effective proxy for real-world variability and significantly enhances robustness without requiring extensive in situ data collection.
From a computational perspective, the evaluated algorithms present distinct complexity profiles that may influence their suitability for real-time deployment. The compression-based ZMCP method requires minimal training time but incurs higher computational cost during identification, since each query sequence must be compared against reference sequences through cross-parsing operations derived from the Lempel–Ziv framework [7,33]. The k-NN classifier exhibits similar behaviour, with negligible training cost but increasing inference time as the number of stored templates grows, which is typical of instance-based learning approaches commonly used in ECG biometrics [2]. In contrast, margin-based classifiers such as SVM require moderate training cost associated with kernel optimisation but provide efficient inference once the decision boundaries are established [2]. Deep Learning models typically present the highest training complexity due to iterative optimisation of network parameters, yet once trained they enable efficient inference through convolution operations and parallel computation, which has contributed to their increasing adoption in ECG biometric recognition systems [8]. These computational considerations reinforce the trade-off between model interpretability, training complexity, and operational robustness observed across the evaluated algorithmic families.
The findings of this study yield several practical implications for ECG-based biometric systems:
  • Noise is one of the primary limiting factors in off-the-person ECG biometrics, necessitating explicit handling at both acquisition and algorithmic levels;
  • Noise-aware data augmentation should be considered as a core component of training strategies, as it generally improves robustness across algorithmic families;
  • Deep Learning and margin-based classifiers emerge as the most promising candidates for deployment in noisy environments when trained with augmented data;
  • Signal quality metrics such as SNR and SQI remain essential tools for quantifying dataset difficulty, guiding preprocessing, and defining operational thresholds.

4.4. Limitations and Future Work

Despite the structured evaluation framework adopted in this study, several limitations are noteworthy. First, although synthetic noise enables controlled and reproducible robustness analysis, it does not fully capture the diversity, nonstationarity, and complex interactions characteristic of real-world disturbances. Of particular significance, only single noise-type contamination was considered. While this restriction was intentional to allow a clear and interpretable characterization of algorithmic sensitivity to individual disturbances, real-world biosignal acquisition typically involves the simultaneous superposition of multiple noise sources. By isolating individual noise types, this work establishes a structured baseline understanding of robustness limits; however, extending the framework to multi-noise superposition models constitutes an important direction for future investigation.
The data augmentation strategy was similarly constrained to a single contamination level (5 dB SNR) per noise type. This choice enabled the evaluation of whether moderate exposure to degraded conditions could already improve robustness. Although measurable gains were observed, particularly for learning-based models, the augmentation scheme does not exhaust the potential benefits of broader strategies. Training across multiple SNR levels spanning a wider range (e.g., −5 dB to 15 dB), as well as incorporating mixtures of heterogeneous noise sources, would likely promote stronger invariance and improved generalization, especially for Deep Learning approaches.
Another important consideration concerns dataset scale. Even with augmentation, the original datasets used for training and evaluation remain relatively limited in size, inherently constraining the models’ capacity to fully exploit their representational potential. Deep Learning methods, in particular, benefit substantially from larger and more diverse training data, while compression-based approaches depend on the statistical richness of the reference sequences. Consequently, the performance reported in this study may underestimate the achievable accuracy of these methods under larger-scales in conjunction with more heterogeneous conditions as previously stated.
With respect to the compression-based ZMCP approach, although it does not rely on explicit morphological feature extraction, the symbolic sequences analyzed are constructed from segmented and amplitude-normalized heartbeat templates aligned via R-peak detection. Thus, while the dissimilarity computation itself is non-fiducial, the preprocessing stage relied on fiducial localization to ensure consistency across algorithmic types.
Future research should explore adaptive and temporally varying noise modeling, expanded multi-level and multi-noise augmentation strategies, subject-dependent robustness analysis, and alternative compression-based dissimilarity measures derived from Ziv–Merhav cross parsing, including the Normalized Compression Distance (NCD) [38] and Cross Parsing Distance (CPD) [39]. Additionally, multimodal biometric fusion (e.g., ECG combined with steering behavior or photoplethysmography) [40] and real-time signal quality-aware decision frameworks represent promising avenues for enhancing robustness in operational environments.

5. Conclusions

This study presented a methodological framework for robustness evaluation and noise-aware training in biosignal-based recognition systems. Although the experimental validation focused on ECG-based biometrics, the proposed methodology is inherently generic and can be extended to other biometric tasks and sensing scenarios subject to noise. The work encompassed biometric recognition under controlled noise degradation, covering classical fiducial-based methods, non-fiducial compression-based approaches, and Deep Learning models. Five representative noise types were systematically considered through a structured data-augmentation strategy applied to publicly available datasets and complemented by validation using real-world ECG recordings acquired with the CardioWheel system.
The results demonstrate that noise is a fundamental limiting factor for ECG biometrics, with broadband and high-frequency disturbances such as AWGN and EMG producing the most severe performance degradation, while structured narrowband interference such as PLI is comparatively less detrimental. Across all algorithmic families, a practical operational boundary was observed, with reliable recognition becoming infeasible below approximately − 5 dB SNR, establishing practical quantitative limits on ECG biometric usability under degraded signal conditions.
Noise-augmented training generally improved robustness, particularly for learning-based classifiers. Learning-based methods, especially Deep Learning and, to a lesser extent, SVM, exhibited the largest performance gains under data augmentation, indicating that noise-aware training enables the learning of more noise-invariant representations. Importantly, models trained with synthetic augmentation generalized effectively to off-the-person recordings, confirming the practical relevance of augmentation strategies. Results from CardioWheel recordings further highlight the challenges of off-the-person ECG acquisition and the importance of training conditions.
Overall, this work underscores the positive impact of noise-aware evaluation and provides actionable guidance for training protocols for biosignals classification systems intended for real-world deployment. While synthetic augmentation cannot yet fully replicate the complexity and variables at play of these applications, it provides a scalable and effective mechanism to improve robustness and bridge the gap between laboratory benchmarks and realistic acquisition environments.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/jeta4020014/s1, Section S1: Tables S1–S9, Section S2: Tables S10–S12 extended experimental results supporting the findings presented in the main manuscript concerning classification performance for of different ECG-based biometric methods across various augmented training data conditions. The open-source framework for biosignal noise-injection and data-augmentation dataset generation used in this work is available at the following repository: ECG Noise Injection Preprocessing Pipeline (https://github.com/DavidEMVelez/ECG-Noise-Injection-Preprocessing-Pipeline, accessed on 31 May 2025).

Author Contributions

Conceptualization, D.V. and A.L.; methodology, D.V. and A.L.; software, D.V., M.P. and D.P.C.; validation, D.V., A.L. and C.C.; formal analysis, D.V., A.L. and C.C.; investigation, D.V.; resources, C.C. and A.L.; data curation, D.V. and C.C.; writing—original draft preparation, D.V.; writing—review and editing, D.V., A.L., M.P. and D.P.C.; visualization, D.V.; supervision, A.L., C.C. and D.P.C. All authors have read and agreed to the published version of the manuscript.

Funding

The work was partially funded by the P2030 T-PRISM project (Toilet Platform for Real-time Integrated Sensing and Monitoring for Analysis) COMPETE2030-FEDER-02975800, and by NOVA LINCS (UID/04516/2025) with the financial support of FCT.IP, DOI https://doi.org/10.54499/UID/04516/2025.

Institutional Review Board Statement

This study was conducted in accordance with the principles of the Declaration of Helsinki and in full compliance with the General Data Protection Regulation (GDPR). All procedures involving human participants were designed to ensure respect for ethical standards, data minimisation, and the protection of personal and biometric data. The collected ECG signals were used exclusively for biometric recognition purposes, without any clinical interpretation or diagnostic intent. Informed consent was obtained from all participants prior to data acquisition.

Data Availability Statement

The datasets used for this study are available from the corresponding author upon reasonable request.

Acknowledgments

The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

Authors David Velez, André Lourenço and Carlos Carreiras were employed by the company CardioID Technologies. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The company CardioID Technologies had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.

References

  1. Prabhakar, S.; Pankanti, S.; Jain, A.K. Biometric recognition: Security and privacy concerns. IEEE Secur. Priv. 2003, 1, 33–42. [Google Scholar] [CrossRef] [Scilit]
  2. Ribeiro Pinto, J.; Cardoso, J.S.; Lourenço, A. Evolution, Current Challenges, and Future Possibilities in ECG Biometrics. IEEE Access 2018, 6, 34746–34776. [Google Scholar] [CrossRef] [Scilit]
  3. Wang, X.; Cai, W.; Wang, M. A novel approach for biometric recognition based on ECG feature vectors. Biomed. Signal Process. Control 2023, 84, 104922. [Google Scholar] [CrossRef] [Scilit]
  4. Mitchell, A.R.J.; Ahlert, D.; Brown, C.; Birge, M.; Gibbs, A. Electrocardiogram-Based Biometrics for User Identification—Using Your Heartbeat as a Digital Key. J. Electrocardiol. 2023, 80, 1–6. [Google Scholar] [CrossRef] [Scilit]
  5. Rathore, A.S.; Li, Z.; Zhu, W.; Jin, Z.; Xu, W. A Survey on Heart Biometrics. ACM Comput. Surv. 2020, 53, 1–38. [Google Scholar] [CrossRef] [Scilit]
  6. Pereira Coutinho, D.; Silva, H.; Gamboa, H.; Fred, A.; Figueiredo, M.A.T. Novel Fiducial and Non-Fiducial Approaches to Electrocardiogram-Based Biometric Systems. IET Biom. 2013, 2, 64–75. [Google Scholar] [CrossRef] [Scilit]
  7. Coutinho, D.P.; Fred, A.L.N.; Figueiredo, M.A.T. One-Lead ECG-Based Personal Identification Using Ziv-Merhav Cross Parsing. In Proceedings of the 20th International Conference on Pattern Recognition (ICPR 2010), Istanbul, Turkey, 23–26 August 2010. [Google Scholar] [CrossRef] [Scilit]
  8. Chiu, J.K.; Chang, C.S.; Wu, S.C. ECG-based Biometric Recognition without QRS Segmentation: A Deep Learning-Based Approach. In Proceedings of the 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC), Yokohama, Japan, 1–5 November 2021. [Google Scholar] [CrossRef] [Scilit]
  9. Luz, E.J.d.S.; Moreira, G.J.P.; Oliveira, L.S.; Schwartz, W.R.; Menotti, D. Learning Deep Off-the-Person Heart Biometrics Representations. IEEE Trans. Inf. Forensics Secur. 2018, 13, 1258–1270. [Google Scholar] [CrossRef] [Scilit]
  10. Rahman, S.; Karmakar, C.; Natgunanathan, I.; Yearwood, J.; Palaniswami, M. Robustness of Electrocardiogram Signal Quality Indices. J. R. Soc. Interface 2022, 19, 20220012. [Google Scholar] [CrossRef] [Scilit]
  11. Mohd Apandi, Z.F.; Ikeura, R.; Hayakawa, S.; Tsutsumi, S. An Analysis of the Effects of Noisy Electrocardiogram Signal on Heartbeat Detection Performance. Bioengineering 2020, 7, 53. [Google Scholar] [CrossRef] [Scilit]
  12. da Silva, H.P.; Carreiras, C.; Lourenço, A.; Fred, A.; das Neves, R.C.; Ferreira, R. Off-the-person electrocardiography: Performance assessment and clinical correlation. Health Technol. 2015, 4, 309–318. [Google Scholar] [CrossRef] [Scilit]
  13. Lourenço, A.; Alves, A.P.; Carreiras, C.; Duarte, R.P.; Fred, A. CardioWheel: ECG Biometrics on the Steering Wheel. In Proceedings of the Machine Learning and Knowledge Discovery in Databases—ECML PKDD 2015; Lecture Notes in Computer Science; Springer: Cham, Switzerland, 2015; Volume 9286, pp. 267–270. [Google Scholar] [CrossRef] [Scilit]
  14. dos Santos Silva, A.; Correia, M.V.; da Costa, A.G.; da Silva, H.P. Toilet-Seat ECG as a Gateway to Stress Monitoring: Non-Invasive Stress Index Extraction in Subjects with and Without Cardiovascular Disease. In Proceedings of the 2025 IEEE 8th Portuguese Meeting on Bioengineering (ENBENG), Aveiro, Portugal, 25–26 September 2025. [Google Scholar] [CrossRef] [Scilit]
  15. Webster, J.G. (Ed.) Medical Instrumentation: Application and Design; John Wiley & Sons: Hoboken, NJ, USA, 2020; p. 928. [Google Scholar]
  16. Meltzer, D.; Luengo, D. ECG-Based Biometric Recognition: A Survey of Methods and Databases. Sensors 2025, 25, 1864. [Google Scholar] [CrossRef] [Scilit]
  17. Biel, L.; Pettersson, O.; Philipson, L.; Wide, P. ECG analysis: A new approach in human identification. IEEE Trans. Instrum. Meas. 2001, 50, 808–812. [Google Scholar] [CrossRef] [Scilit]
  18. Silva, A.S.; Correia, M.V.; de Melo, F.; da Silva, H.P. Identity Recognition in Sanitary Facilities Using Invisible Electrocardiography. Sensors 2022, 22, 4201. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Pereira, L.; Plácido da Silva, H. A Novel Smart Chair System for Posture Classification and Invisible ECG Monitoring. Sensors 2023, 23, 719. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Shen, T.W.; Tompkins, W.J.; Hu, Y.H. One-lead ECG for identity verification. In Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society, Houston, TX, USA, 23–26 October 2002. [Google Scholar] [CrossRef] [Scilit]
  21. Pinto, J.R.; Cardoso, J.S.; Lourenço, A.; Carreiras, C. Towards a Continuous Biometric System Based on ECG Signals Acquired on the Steering Wheel. Sensors 2017, 17, 2228. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  22. Martinho, M.; Fred, A.; Silva, H. Towards Continuous User Recognition by Exploring Physiological Multimodality: An Electrocardiogram (ECG) and Blood Volume Pulse (BVP) Approach. In Proceedings of the 2018 International Symposium in Sensing and Instrumentation in IoT Era (ISSI), Shanghai, China, 6–7 September 2018. [Google Scholar] [CrossRef] [Scilit]
  23. Moody, G.B.; Mark, R.G. The impact of the MIT-BIH Arrhythmia Database. IEEE Eng. Med. Biol. Mag. 2001, 20, 45–50. [Google Scholar] [CrossRef] [Scilit]
  24. Goldberger, A.L.; Amaral, L.A.N.; Glass, L.; Hausdorff, J.M.; Ivanov, P.C.; Mark, R.G.; Mietus, J.E.; Moody, G.B.; Peng, C.K.; Stanley, H.E. PhysioBank, PhysioToolkit, and PhysioNet: Components of a New Research Resource for Complex Physiologic Signals. Circulation 2000, 101, e215–e220. [Google Scholar] [CrossRef] [Scilit]
  25. Moody, G.B.; Mark, R.G. MIT-BIH Arrhythmia Database. PhysioNet, 2005. Expanded Version Released on PhysioNet, 24 February 2005. Available online: https://physionet.org/content/nstdb/1.0.0/ (accessed on 29 March 2026).
  26. Lugovaya, T.S. Biometric Human Identification Based on Electrocardiogram. Master’s Thesis, Electrotechnical University “LETI”, Saint-Petersburg, Russia, 2005. [Google Scholar]
  27. Lugovaya, T.S. ECG-ID Database: Biometric Human Identification based on ECG 2014. Database Released on PhysioNet, 6 March 2014. Available online: https://physionet.org/content/ecgiddb/1.0.0/ (accessed on 29 March 2026).
  28. Moody, G.B.; Muldrow, W.E.; Mark, R.G. A Noise Stress Test for Arrhythmia Detectors. Comput. Cardiol. 1984, 11, 381–384. [Google Scholar]
  29. Jain, A.K.; Ross, A.; Prabhakar, S. An Introduction to Biometric Recognition. IEEE Trans. Circuits Syst. Video Technol. 2004, 14, 4–20. [Google Scholar] [CrossRef] [Scilit]
  30. Jain, A.K.; Flynn, P.; Ross, A.A. Handbook of Biometrics; Springer: Berlin/Heidelberg, Germany, 2008. [Google Scholar] [CrossRef] [Scilit]
  31. Ziv, J.; Merhav, N. A Measure of Relative Entropy Between Individual Sequences with Application to Universal Classification. IEEE Trans. Inf. Theory 1993, 39, 1270–1279. [Google Scholar] [CrossRef] [Scilit]
  32. Ziv, J.; Lempel, A. A Universal Algorithm for Sequential Data Compression. IEEE Trans. Inf. Theory 1977, 23, 337–343. [Google Scholar] [CrossRef] [Scilit]
  33. Coutinho, D.P.; Fred, A.L.N.; Figueiredo, M.A.T. Personal Identification and Authentication based on One-lead ECG using Ziv-Merhav Cross Parsing. In Proceedings of the 10th International Workshop on Pattern Recognition in Information Systems (ICEIS 2010); SCITEPRESS—Science and Technology Publications, Lda.: Setúbal, Portugal, 2010; pp. 15–24. [Google Scholar] [CrossRef] [Scilit]
  34. Labati, R.D.; Muñoz, E.; Piuri, V.; Sassi, R.; Scotti, F. Deep-ECG: Convolutional Neural Networks for ECG biometric recognition. Pattern Recognit. Lett. 2019, 126, 78–85. [Google Scholar] [CrossRef] [Scilit]
  35. Ihsanto, E.; Ramli, K.; Sudiana, D.; Gunawan, T.S. Fast and Accurate Algorithm for ECG Authentication Using Residual Depthwise Separable Convolutional Neural Networks. Appl. Sci. 2020, 10, 3304. [Google Scholar] [CrossRef] [Scilit]
  36. Zhao, Z.; Zhang, Y. SQI Quality Evaluation Mechanism of Single-Lead ECG Signal Based on Simple Heuristic Fusion and Fuzzy Comprehensive Evaluation. Front. Physiol. 2018, 9, 727. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Clifford, G.D.; Behar, J.; Li, Q.; Rezek, I. Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms. Physiol. Meas. 2012, 33, 1419–1433. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Li, M.; Chen, X.; Li, X.; Ma, B.; Vitányi, P.M.B. The Similarity Metric. IEEE Trans. Inf. Theory 2004, 50, 3250–3264. [Google Scholar] [CrossRef] [Scilit]
  39. Helmer, S.; Augsten, N.; Böhlen, M.H. Measuring Structural Similarity of Semistructured Data Based on Information-Theoretic Approaches. VLDB J. 2012, 21, 677–702. [Google Scholar] [CrossRef] [Scilit]
  40. Esteves, T.; Ribeiro Pinto, J.; Ferreira, P.M.; Amaro Costa, P.; Abrunhosa Rodrigues, L.; Antunes, I. AUTOMOTIVE: A Case Study on Automatic Multimodal Drowsiness Detection for Smart Vehicles. IEEE Access 2021, 9, 153678–153700. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.