Abstract
Particle deposition in separated flows depends on both the carrier-flow structure and particle size, yet their combined effects can vary across flow regimes. This study investigates particle transport and wall deposition downstream of a backward-facing step for nine Reynolds numbers ranging from 500 to 8000 and particle diameters from 10 to 100 μm. Large-eddy simulation coupled with Lagrangian particle tracking is employed to examine deposition efficiency, spatial deposition distributions, and particle transport pathways. In the laminar regime, deposition efficiency remains approximately 81–85% for particles smaller than about 35 μm and generally decreases at larger diameters. The transitional regime exhibits pronounced nonmonotonic variations, with deposition efficiency reaching approximately 12% near 35–40 μm at Re = 3000 before recovering to approximately 58% at 60 μm. In the turbulent regime, deposition efficiency remains within a comparatively narrow range of approximately 54–59%. Spatial deposition distributions and particle trajectories reveal diameter-dependent transport characteristics even when global deposition efficiencies are similar. The results indicate that particle inertia must be considered together with the Reynolds-number-dependent carrier-flow structure when interpreting deposition behavior. The predicted deposition efficiencies remain conditional on the adopted numerical framework, injection conditions, and particle–wall interaction assumptions.
1. Introduction
Flow over a backward-facing step (BFS) provides a controlled setting for studying separation, shear-layer development, and reattachment. The sudden expansion forces the incoming stream away from the lower wall and creates a region of reduced or reversed flow beneath the separated shear layer. As the layer develops downstream, it exchanges momentum with the surrounding fluid and modifies near-wall velocity gradients. These features are relevant to pressure loss, mixing, heat transfer, and the transport of suspended material in ducts and other passages with abrupt changes in cross-section. Experimental investigations have established the BFS as a reference configuration for studying reattachment, turbulence, and heat transfer [1,2,3,4]; a subsequent review summarizes its principal flow mechanisms and applications [5].
The response to Reynolds number depends on the balance between inertia and viscous diffusion. At relatively low Reynolds numbers, viscous effects can damp disturbances generated near the step, leaving an organized recirculating region and a comparatively smooth shear layer. Measurements at a step-based Reynolds number of 5000 provide a useful reference for reattachment-flow velocity and stress profiles [6]. With increasing Reynolds number, disturbances may grow, roll into coherent structures, and produce more persistent downstream unsteadiness [1,7]. At higher Reynolds numbers, interaction among structures of different sizes changes the distribution of velocity fluctuations and the development of the reattaching flow [3,8,9]. Experiments at high Reynolds numbers have also documented the dependence of the mean separation bubble on Reynolds number and expansion ratio [10]. The transition between these behaviors is sensitive to the Reynolds-number definition, expansion ratio, channel geometry, inlet boundary layer, and disturbances entering the domain. Consequently, laminar, transitional, and turbulent labels must be interpreted in relation to the specific configuration rather than as universal Reynolds-number thresholds [1,5,7].
In separated channel flows, particle deposition is governed by the interaction between particle dynamics and the evolving carrier flow. The separated shear layer, recirculation region, and downstream recovery influence particle transport through distinct mechanisms. A description of the mean flow and its fluctuations is therefore needed to interpret where particles deposit and how deposition changes along the channel.
Particles encounter a spatially nonuniform carrier flow in the expanded passage. Those remaining in the faster upper stream may cross the channel rapidly, whereas particles entering the slower lower region experience a different combination of residence time, flow curvature, and proximity to solid surfaces. Experiments on particle dispersion downstream of a single-sided step demonstrate the importance of this separated-flow geometry for particle transport [11]. Particle inertia can cause trajectories to depart from fluid streamlines, and changes in diameter alter the response to local velocity variations [12,13]. Deposition can also depend on settling, turbulent transport, and near-wall interactions, although the importance of these mechanisms varies with the particle and flow properties [12]. A change in flow regime therefore does not produce the same change in deposition efficiency for every particle diameter [12,13].
The effect of particle size is coupled to the characteristic time scales of the carrier flow. In the low-particle-Reynolds-number limit, particle response time increases approximately with the square of diameter, so particles of different sizes can react differently to the same shear-layer motion [12,13,14]. Increasing the flow Reynolds number can also change advection time, the structure of the separated region, and the paths available to particles. Near-wall transport and surface conditions further influence deposition [15,16]. Whether these changes raise or lower the fraction deposited depends on where particles travel and which surfaces they contact. The combined effects of Reynolds number and particle diameter therefore provide a more complete picture of deposition than either parameter considered in isolation.
Particle transport over backward-facing steps (BFS) has been examined in previous studies, although the studies differ in their focus. More broadly, the particle-laden-flow literature identifies particle loading as a factor in determining whether the dispersed phase affects the carrier flow [17]. BFS measurements show that particles can modify turbulence under certain loading and flow conditions [18]. Previous studies employed a Reynolds-stress model and discrete-particle tracking to examine how flow speed, particle diameter, and expansion ratio affect deposition efficiency in duct flow [19]. Other studies investigated particle deposition in BFS flow in the context of a radiant syngas cooler [20]. Previous studies also used LES with a filtered-density-function treatment to investigate the contribution of unresolved motions to gas–particle dispersion downstream of a step [21]. These differing configurations and modeling choices limit direct comparisons of deposition trends based solely on Reynolds number.
Large-eddy simulation (LES), coupled with Lagrangian particle tracking, has become a useful approach for studying particle transport in separated flows. LES captures the unsteady, energy-containing structures of the carrier flow while accounting for the effects of unresolved scales through a subgrid model [22,23,24]. This approach makes it possible to investigate how the separated shear layer and recirculation region influence deposition for different particle diameters and Reynolds numbers. Comparisons across these conditions require consistent definitions of the governing parameters and deposition metrics, together with adequate numerical resolution and statistical sampling [25].
The contribution of the present study is a systematic comparison of particle-size-dependent deposition across laminar, transitional, and turbulent flow regimes within a common backward-facing-step geometry. Simulations cover nine Reynolds numbers from 500 to 8000 and particle diameters from 10 to 100 μm, combining carrier-flow characterization with Lagrangian particle tracking. This comparison identifies distinct deposition responses: a sustained decrease beyond a Reynolds-number-dependent particle diameter in the laminar cases, pronounced minima followed by recovery in the transitional cases, and comparatively weak diameter dependence in the turbulent cases. In particular, the transitional cases reveal that increasing particle size can substantially reduce deposition before promoting its recovery at larger diameters. These findings extend the discussion of individual deposition trends by demonstrating how the sensitivity to particle diameter changes across flow regimes and by examining possible relationships with the separated carrier-flow structure.
2. Computational Model and Method
2.1. Governing Equations
2.1.1. Continuum Phase
The flow over a backward-facing step (BFS) was investigated numerically using large-eddy simulation (LES). The computational geometry consisted of an upstream channel, a sudden expansion of height h, and a downstream channel sufficiently long to capture flow separation, recirculation, reattachment, and subsequent redevelopment [26,27,28,29,30]. The upstream and downstream lengths were Li = 10 h and Lo = 35 h, respectively [28]. The expansion ratio, defined as the ratio of the downstream channel height to the upstream channel height, was ER = 2 [28]. The spanwise width of the domain was W = 8 h [28]. The Reynolds number was defined using the step height and the bulk velocity upstream of the step:
where U0 is the bulk inlet velocity, h = 0.01 m is the step height, and ν = 1.506 × 10−5 m2/s is the kinematic viscosity of the carrier fluid. As already mentioned, the simulations were performed at Re = 500, 750, 1000, 1500, 3000, 5000, 6000, 7000, and 8000 to examine the separated flow across laminar, transitional, and turbulent regimes. The Reynolds number corresponding velocities are presented in Table 1.
Table 1.
Reynolds numbers and corresponding velocities.
The fluid was assumed to be incompressible and Newtonian, with constant thermophysical properties. The governing equations of the large-eddy simulation (LES) are the space-filtered Navier–Stokes equations, given by
where is the subgrid-scale (SGS) stress term, which needs to be modeled. In this LES model, we employ an eddy-viscosity model given by Equation (4)
or
where the strain rate Sij is given by Equation (6)
Thus, |τij| can be rewritten as
where
The dynamic SGS model is based on the identity (8)
where Lij is the resolved stress tensor and Tij is the sub-grid stress tensor, at the test filter scale. Thus, the LES governing equations become
where . For more details on the large-eddy simulation approach, the reader is referred to [23,26,27].
2.1.2. Particulate Phase
In the present research, we employ the Lagrangian approach for the prediction of silica-particle transport and deposition. The particulate phase is represented by a number of computational particles whose trajectories xp(t) are computed by simultaneously integrating:
In Equations (10) and (11), the subscripts p and f denote, respectively, the particle and carrier fluid. In Equation (11), a represents the particle’s radius. For more details regarding the Lagrangian particle tracking, the reader may refer to [17]. Equation (11) represents the balance of forces acting on the particle as the particle moves through the carrier fluid flow. The term mp(dupi/dt) represents the inertia force acting on the particle due to its acceleration. The term mp(ufi − upi)/τp represents the forces due to viscous and pressure drag. The term mf(Dufi/Dt) represents the fluid pressure gradient and viscous stresses. The term represents the inertia of virtual mass. The term represents the viscous drag due to the unsteady relative acceleration. The term (mp − mf)gi represents the body force. The term represents the Saffman lift force due to shear in the carrier flow. For the investigated silica particles, whose material density is substantially greater than that of the carrier fluid, a reduced Lagrangian particle-motion formulation retaining aerodynamic drag and gravity is adopted. Silica particles were selected as representative high-density solid particles for investigating inertial transport and deposition. Previous investigations have examined the influence of particle properties and gravitational effects on silica-particle deposition [31]. The corresponding three-dimensional equation of particle motion in Cartesian coordinates is expressed as follows:
where γ is a drag correction factor that extends the validity of the Stokes flow regime for higher particle Reynolds numbers 0 < Rep < 800. In Equation (12), the term represents the particle relaxation time, and for spherical particles CD = 24γ/Rep. The particle Reynolds number is defined as
where ρf and μf denote the density and dynamic viscosity of the carrier fluid, respectively. The characteristic length is the particle diameter, dp, and the characteristic velocity is the magnitude of the local slip velocity of the carrier fluid evaluated at the particle position, uf(xp,t), and the particle velocity, up. Thus, Rep characterizes the relative flow around an individual particle, whereas the flow Reynolds number in Equation 1 is based on the bulk inlet velocity and step height.
The motion of particles suspended in a fluid is governed by several forces, including aerodynamic drag, gravity, pressure-gradient forces, added mass, shear-induced lift, and unsteady history effects. The theoretical framework developed by Maxey and Riley (1983) [13] provides a fundamental description of the forces acting on small spherical particles, while Elghobashi (1994) [17] discusses the modeling of particle-laden turbulent flows and the importance of particle inertia and particle–fluid interactions. In the present investigation, a reduced particle-force formulation retaining aerodynamic drag and gravity is employed [13]. The investigated silica particles have a material density of 2650 kg/m3. Assuming an air density of approximately 1.2 kg/m3, the particle-to-fluid density ratio is approximately 2208, indicating that the particles are substantially denser than the carrier fluid. The corresponding fluid-to-particle density ratio is
For comparable characteristic fluid and particle acceleration scales, the pressure-gradient force relative to particle inertia scales with . Similarly, the coefficient associated with the added-mass contribution, relative to particle mass, is approximately
The buoyancy correction relative to particle weight is also small, approximately 0.045%. These estimates suggest that pressure-gradient, added-mass, and buoyancy contributions are relatively small under the stated scaling assumptions [13,17]. Aerodynamic drag is retained as the principal mechanism governing the particle response to the local carrier-flow velocity, while gravitational acceleration accounts for particle settling. A finite-particle-Reynolds-number correction is applied to the drag formulation to account for departures from the Stokes-flow regime. The neglect of shear-induced lift and unsteady history forces represents an additional modeling approximation. Unlike the pressure-gradient and added-mass contributions under comparable acceleration scales, their relative importance cannot be established solely from the particle-to-fluid density ratio. These forces may become relevant in regions of strong velocity gradients, rapidly varying particle–fluid slip, or near-wall transport. Consequently, the predicted particle trajectories and deposition efficiencies should be interpreted within the limitations of the adopted drag-and-gravity formulation [13].
It is important to mention here that the solid particle chosen for investigation in this research is silica, which has a molar mass of 60.08 g/mol and a density of 2650 kg/m3. Silica particles were selected as a representative mineral dust relevant to particle transport and deposition in engineered flows. Their relatively high density (2650 kg/m3) makes particle inertia an important consideration when examining how deposition varies with particle diameter and Reynolds number.
Particle-Tracking Temporal Resolution
The characteristic particle response time was estimated using the Stokes relaxation-time expression
where ρp is the particle density, dp is the particle diameter, and μ is the dynamic viscosity of the carrier fluid. For silica particles with a density of 2650 kg/m3 and representative diameters of 10, 40, and 60 μm, the estimated relaxation times are 8.15 × 10−4, 1.3 × 10−2 s, and 2.93 × 10−2 s, respectively, using μ = 1.807 × 10−5 Pa∙s. The carrier-flow time step was fixed at ∆t = 2 × 10−5 s, corresponding to ratios of of approximately 0.0245, 0.00154, and 0.000682 for the three particle diameters, respectively. These relatively small ratios indicate that the temporal resolution of the carrier-flow solution is finer than the characteristic particle response times. Particle trajectories were calculated using an unsteady Lagrangian particle-tracking approach implemented in ANSYS Fluent 2025. Individual particles were tracked through the evolving transient LES velocity field by numerically integrating their equations of motion. This approach accounts for the temporal evolution of the resolved carrier-flow structures during particle transport. The comparison between the carrier-flow time step and the characteristic particle relaxation times provides an assessment of the relevant temporal scales.
Particles were released as a single batch from four injection regions, with 1000 computational particles per region, giving a total of 4000 particles per tracking calculation.
A trapping boundary condition was imposed at the upper and lower walls in the baseline simulations. Under this idealized perfect-capture assumption, particles reaching these surfaces were classified as deposited, and their trajectories were terminated. This treatment provides a consistent reference condition for evaluating the combined effects of Reynolds number and particle diameter on particle transport and deposition. However, it does not represent a material-specific adhesion model for silica particles, since actual particle capture and rebound depend on impact conditions, surface properties, and interfacial forces. To evaluate the sensitivity of the deposition predictions to this assumption, an alternative wall-interaction treatment incorporating partial absorption and rebound was also investigated, as discussed in Section 3.2.2.
2.2. Computational Model
2.2.1. Computational Domain
Figure 1 presents the schematic of the computational domain and coordinate system. The flow enters from the left and passes over a backward-facing step of height (h). The upstream channel height is (h), whereas the downstream channel height is H = 2 h. The upstream and downstream section lengths are denoted by Li = 10 h and Lo = 35 h, respectively, and W = 8 h represents the channel width. The values of Li and Lo, respectively, and W, are based on previous studies [29,30,31,32,33,34]. The upstream section provides a finite distance between the prescribed inlet boundary and the step, allowing the incoming flow to adjust before separation. Because a uniform inlet velocity profile is prescribed, this length is not intended to establish fully developed channel flow. The downstream section provides space for the separated shear layer, recirculation region, reattachment, and subsequent flow recovery, while placing the outlet away from the principal region of interest.
Figure 1.
Schematic of the flow and geometric configurations.
The computational domain and mesh distribution are illustrated in Figure 2. A structured Cartesian mesh is employed throughout the domain, with local refinement near the solid walls and the shear-layer developing areas to accurately resolve the steep velocity gradients in these regions. The grid spacing is gradually increased away from the walls to reduce the overall computational cost while maintaining adequate resolution in the core-flow region. For clarity, only one out of every four grid nodes is shown.
Figure 2.
Computational domain.
2.2.2. Boundary Conditions and Initial Conditions
A prescribed velocity boundary condition was applied at the inlet. The bulk velocity was adjusted for each case to achieve the required Reynolds number, and a uniform velocity profile was specified. A constant static-pressure condition was imposed at the outlet, while Dirichlet velocity boundary conditions were applied to all solid walls. Periodic boundary conditions were imposed on the paired spanwise boundaries to represent a channel repeating in the spanwise direction. This treatment permits three-dimensional velocity fluctuations across the paired boundaries without imposing a symmetry-plane constraint. The finite spanwise width determines the spanwise wavelengths that can be represented in the computational domain.
For all nine Reynolds-number cases (Reh = 500, 750, 1000, 1500, 3000, 5000, 6000, 7000, and 8000), the initial flow field was obtained from a converged RANS solution using the shear-stress-transport (SST) k–ω model. SST was selected for its treatment of near-wall flow and separation under adverse pressure gradients. Each RANS solution initialized the corresponding LES calculation, which was subsequently advanced to capture the temporal development of the separated flow. The SST k–ω model was used exclusively for initialization, whereas the LES subgrid-scale stresses were modeled using the dynamic Smagorinsky model.
The dynamic Smagorinsky model was selected because its coefficient is evaluated from the resolved flow using the Germano identity, allowing the modeled SGS eddy viscosity to adapt to local flow conditions rather than prescribing a constant coefficient [23,26,27]. This adaptability is useful in backward-facing-step flow, where near-wall regions, the separated shear layer, and downstream recovery exhibit different turbulence characteristics. The closure represents the deviatoric SGS stress using a scalar eddy viscosity proportional to the resolved strain-rate tensor. This approximation limits the representation of unresolved stress anisotropy, particularly near walls and in the separated shear layer. It does not impose isotropy on the resolved velocity fluctuations, whose anisotropy can develop directly in the LES. The isotropic component of the SGS stress is absorbed into the modified pressure.
2.2.3. Numerical Schemes
The governing equations were discretized using the finite-volume method. The convective terms in the momentum equations were discretized using a second-order central-differencing scheme. Temporal discretization employed a second-order implicit scheme with a fixed time step of Δt = 2 × 10−5 s. All simulations were performed on a high-performance computing system using the Message Passing Interface (MPI) for parallelization.
2.2.4. Grid and Time-Step Sensitivity
A three-dimensional mesh containing approximately 12 × 106 grid points is used for the final simulations. The mesh was refined near the step edge, within the separated shear layer, throughout the recirculation region, and close to the solid walls as shown in Figure 2. These regions contain the strongest velocity gradients and are therefore critical to predicting separation, vortex formation, and reattachment. The near-wall resolution was assessed using
where y is the distance from the wall to the center of the first computational cell and is the friction velocity. The resulting resolution was . Numerical sensitivity was examined using three systematically refined meshes containing approximately 9.6×106, 11.4 × 106, and 12.1 × 106 grid points. The grid-refinement assessment was informed by established procedures for evaluating discretization uncertainty in computational fluid dynamics, as described by Celik et al. [25]. The assessment considered the mean streamwise velocity profiles downstream of the step at x/h = 5 and x/h = 9, as shown in Figure 3. The selected mesh was considered sufficiently resolved when further refinement produced only minor changes in these quantities. A constant time step of Δt = 2.0 × 10−5 s was used. The corresponding Courant number was monitored and remained below 1. The time step was selected to resolve the motion of the separated shear layer and the dominant vortex-shedding frequencies. Each time step was considered converged when the normalized residuals decreased below 10−6, together with satisfactory conservation of mass and momentum. The selected value of Δt = 2.0 × 10−5 provided an appropriate balance between temporal resolution and computational cost. A temporal sensitivity assessment was performed for Re = 3000 by reducing the time step from 2 × 10−5 s to 1 × 10−5 s. The resulting changes in the mean reattachment length and selected resolved velocity statistics were below 1%, indicating limited sensitivity to further temporal refinement and supporting the adequacy of the selected time step for the carrier-flow calculations. The spatial and temporal verification procedures followed accepted practices for unsteady CFD simulations [25].
Figure 3.
Grid convergence.
2.2.5. Statistical Sampling and Averaging-Duration Sensitivity
The sensitivity of the resolved flow statistics to the statistical sampling duration was investigated for three representative Reynolds numbers, Re = 750, 3000, and 7000, corresponding to the laminar, transitional, and turbulent flow regimes, respectively. All LES calculations were initialized using converged SST k − ω RANS solutions. A fixed time step of Δt = 2 × 10−5 s was employed. The normalized resolved streamwise Reynolds normal stress, , was examined at two downstream locations, x/h = 5 and x/h = 9. Three cumulative statistical sampling intervals, 0–1.6, 0–2.4, and 0–3.2 s, were considered, corresponding to 80,000, 120,000, and 160,000 time steps, respectively. The normalized resolved streamwise Reynolds normal stress, R, and the relative L2 difference between each Reynolds-stress profile and the 3.2 s reference profile were defined as follows:
where Rt,i represents the normalized Reynolds-stress value at spatial location i for the sampling interval ending at time t, Rref,i is the corresponding value obtained using the 3.2 s reference interval, and N denotes the number of spatial sampling points. For Re = 750, the relative differences decreased from 2.87% to 0.70% at x/h = 5, and from 5.26% to 2.41% at x/h = 9, as the cumulative sampling endpoint increased from 1.6 to 2.4 s. For Re = 3000, the corresponding differences decreased from 3.40% to 1.13% and from 1.76% to 0.83%, respectively. At Re = 7000, the differences decreased from 1.94% to 0.80% at x/h = 5, and from 2.07% to 0.83% at x/h = 9.
The relative differences in the normalized streamwise Reynolds normal-stress profiles for the three representative Reynolds numbers, evaluated at x/h = 5 and x/h = 9 over different sampling durations, are summarized in Table 2.
Table 2.
Relative differences in normalized streamwise Reynolds normal-stress profiles across sampling durations.
Figure 4, Figure 5 and Figure 6 compare the normalized resolved streamwise Reynolds normal-stress profiles obtained using the three cumulative sampling intervals for Re = 750, 3000, and 7000 at x/h = 5 and x/h = 9. The comparisons indicate that the profiles obtained using the 2.4 s sampling interval exhibit smaller differences relative to the 3.2 s reference profiles than those obtained using the 1.6 s interval. This behavior is observed for all three Reynolds numbers at both downstream locations. The largest remaining relative difference for the 2.4 s sampling interval is 2.41%, occurring at Re = 750 and x/h = 9.
Figure 4.
Averaging-duration sensitivity of normalized streamwise Reynolds stress at Re = 750.
Figure 5.
Averaging-duration sensitivity of normalized streamwise Reynolds stress at Re = 3000.
Figure 6.
Averaging-duration sensitivity of normalized streamwise Reynolds stress at Re = 7000.
The characteristic flow-through time was estimated as
where L = 0.45 m is the computational domain length and U0 is the reference inlet velocity. The number of flow-through times was therefore calculated as
Using these definitions, the cumulative sampling durations of 1.6–3.2 s correspond to approximately 4.02–8.03 flow-through times for Re = 750, 16.06–32.13 for Re = 3000, and 37.48–74.97 for Re = 7000, respectively. The decreasing relative differences indicate reduced sensitivity of the selected second-order velocity statistics to increasing sampling duration. However, statistical accumulation began at the start of the LES calculations, and the reported cumulative statistics therefore include the initial LES adjustment period. Although the simulations were initialized using converged SST k–ω RANS solutions, this does not independently establish statistical stationarity of the resolved LES fluctuations. Consequently, the present comparisons quantify averaging-duration sensitivity rather than demonstrating fully converged post-transient flow statistics.
2.2.6. Carrier-Flow Validation
Figure 7 compares the LES-predicted and experimentally measured normalized mean streamwise velocity profiles [31] at x/h = 2, 7, 9, and 12. Despite minor localized discrepancies, good agreement is observed at all four locations. The LES captures near-wall flow reversal and downstream velocity recovery, supporting its use for the subsequent particle-transport analysis.
Figure 7.
Comparison of LES-predicted and experimentally measured normalized velocity.
3. Results
3.1. Carrier-Flow Characteristics Across Flow Regimes
The instantaneous velocity and spanwise-vorticity fields reveal increasing shear-layer complexity with Reynolds number. In the laminar regime, disturbances decay at Re = 500, become intermittent at Re = 750, and persist at Re = 1000.
Transitional flows exhibit increasingly extensive shear-layer deformation, whereas turbulent flows are characterized by persistent, complex vortical structures [29,30,32,33,34].
Figure 8 compares the normalized streamwise velocity profiles across the three flow regimes at x/h = 5 and 9. In the laminar regime, the maximum normalized velocity at x/h = 5 increases from approximately 1.5 to 1.9 between Re = 750 and 1000. Transitional flows exhibit Reynolds-number-dependent variations in flow reversal, whereas turbulent flows show downstream velocity recovery at x/h = 9. These differences in shear-layer dynamics and momentum redistribution provide distinct transport environments that may influence particle trajectories, residence times, and deposition.
Figure 8.
Normalized streamwise velocity profiles.
The temporal evolution of the instantaneous velocity fields for the laminar, transitional, and turbulent regimes is presented in the Supplementary Materials (Figures S1–S3, S13–S15 and S25–S27, respectively). The corresponding instantaneous spanwise-vorticity fields, illustrating the Reynolds-number-dependent development of vortical structures within the separated flow, are provided in Figures S4–S6, S16–S18 and S28–S30 of the Supplementary Materials. Additional distributions of modeled turbulence kinetic energy and the corresponding eddy-dissipation quantity for the three flow regimes are presented in the Supplementary Materials (Figures S7, S8, S19, S20, S31 and S32). The normalized streamwise Reynolds normal-stress and shear-stress profiles at x/h = 5 and x/h = 9 are provided in Figures S9, S10, S21, S22, S33 and S34 of the Supplementary Materials, providing additional characterization of the downstream development of velocity fluctuations and momentum transport. The streamwise distributions of the pressure and skin-friction coefficients are presented in Figures S11, S12, S23, S24, S35 and S36 of the Supplementary Materials, complementing the carrier-flow analysis through additional characterization of pressure recovery and wall-shear development.
3.2. Particle Deposition: Validation and Sensitivity
3.2.1. Particle-Phase Validation
The predicted particle-size dependence was compared with the numerical investigation of Lu and Zhao (2018) [35], who examined particle deposition in turbulent duct flows containing forward- or backward-facing steps. Although differences in geometry, flow conditions, and modeling assumptions limit direct quantitative comparisons, the published results provide a useful numerical benchmark for interpreting the particle-size-dependent deposition trends obtained in the present study. The current results using the LES along with Lagrangian particle tracking (LPT) and previous studies which used the Reynolds stress model (RSM) along with the discrete particle method (DPM) show good agreement, as shown in Figure 9. The published results show a decrease in their deposition-efficiency ratio over an intermediate diameter range, followed by a partial recovery at larger diameters. The present transitional cases likewise exhibit nonmonotonic deposition behavior, with pronounced minima and subsequent recovery. This comparison supports the quantitative finding that particle deposition downstream of a backward-facing step does not vary monotonically with diameter. This nonmonotonic variation in deposition efficiency with particle diameter was also observed in the current study for laminar, transitional and turbulent flow regimes.
Figure 9.
Particle deposition; data validation.
The non-monotonic deposition behavior can be interpreted as competition between particle entrainment by the separated flow and inertia-driven wall contact. Smaller particles respond more readily to changes in the carrier-flow velocity and can follow trajectories that bring them toward deposition surfaces. As particle diameter increases, the particle relaxation time increases approximately with the square of diameter in the Stokes-drag limit. Particles consequently become less responsive to flow turning and may bypass wall-directed or recirculating trajectories, reducing deposition at intermediate diameters. At larger diameters, stronger inertia can promote wall interception, while gravitational settling, where relevant, provides an additional route to deposition. These competing effects offer a plausible explanation for the subsequent recovery in deposition efficiency. Changes in the separated-flow structure and transport time scales with Reynolds number can shift the diameter at which the minimum occurs. This interpretation remains qualitative because the deposition-efficiency curves alone do not establish the relative contributions of these mechanisms.
In this study, the validation of the particle-phase predictions is constrained by the scarcity of benchmark studies spanning the flow regimes considered here. Independent experimental particle-deposition data matching the investigated geometry and operating conditions were unavailable. Comparison with one previously published numerical study provides a limited assessment of consistency with existing predictions but does not establish accuracy against independent measurements. Particle-number convergence and sensitivity assessments further evaluate selected numerical and modeling dependencies. These assessments do not independently establish the quantitative accuracy of the predicted deposition efficiencies. Accordingly, the reported deposition efficiencies are interpreted as model predictions conditional on the prescribed injection conditions and particle–wall interaction treatment.
The validation and numerical consistency assessments presented in this study address distinct aspects of the computational methodology. The carrier-flow predictions were validated through comparisons with available experimental measurements, whereas the particle-number convergence and sensitivity analyses assess selected numerical and modeling dependencies of the particle-tracking predictions. Additionally, the particle-deposition results were compared with the numerical investigation of Lu and Zhao (2018) [35], whose methodology demonstrated good agreement with experimental measurements under the validation conditions considered. This comparison provides qualitative support for the predicted particle-size-dependent deposition trends. However, differences in computational configurations, deposition measures, particle properties, and modeling assumptions prevent direct quantitative validation of the present results. Accordingly, this comparison is regarded as qualitative benchmarking against a previously validated numerical investigation rather than independent experimental validation of the present particle-deposition predictions.
3.2.2. Particle Deposition Sensitivity
Particle-number convergence was assessed at Re = 3000 for 40 μm particles by increasing the total number of injected particles from 4000 to 8000 and 16,000, equally distributed among four injection regions, as shown in Table 3. Deposition efficiency decreased from 12.4% to 12.1% and 12.0%, respectively. The difference between the two highest particle counts was 0.10 percentage points, corresponding to a relative difference of 0.83% with respect to the 16,000-particle result. The change across the full particle-number range was 0.40 percentage points. These results indicate decreasing sensitivity to particle number as sampling increases for this condition.
Table 3.
Particle-number convergence assessment based on deposition efficiency.
Although the particle-number convergence assessment demonstrates decreasing sensitivity to the number of injected particles, it does not establish statistical convergence with respect to the unsteady carrier-flow field. In the present simulations, particles were released as a single batch and subsequently tracked through the evolving transient LES velocity field. However, the sensitivity of deposition efficiency to different particle-release times was not independently evaluated. A systematic assessment involving multiple particle-release realizations at statistically separated times was beyond the scope of the present investigation, which primarily focused on the combined effects of Reynolds number and particle diameter on particle transport and deposition. Consequently, the reported deposition efficiencies should be interpreted as conditional on the investigated release conditions. Future investigations incorporating multiple particle-release realizations and statistical uncertainty quantification would help establish the robustness of the observed deposition trends.
Sensitivity to particle injection location was assessed, for Re =3000, by shifting the original injection positions upward and downward by 0.05 h, where h denotes the step height. Each case used 4000 injected particles, and particle diameters of 10, 40, and 60 μm were considered, as shown in Table 4. For 10 μm particles, deposition efficiency changed from 54.05% at the original location to 52.70% and 55.30% for the upward and downward shifts, respectively. Corresponding efficiencies were 12.40%, 11.70%, and 13.30% for 40 μm particles, and 57.75%, 57.55%, and 58.45% for 60 μm particles. The maximum absolute changes were 1.35, 0.90, and 0.70 percentage points, corresponding to relative changes of 2.50%, 7.26%, and 1.21%, respectively, with respect to the original injection arrangement. Although the absolute changes were small, the relative sensitivity was greatest for 40 μm particles because of their lower baseline efficiency.
Table 4.
Sensitivity of particle deposition efficiency to injection location for different particle diameters.
A third sensitivity analysis examined the influence of the particle–wall interaction treatment for Re = 3000. Table 5 summarizes the perpendicular and parallel restitution coefficients, which were both zero in Case 1 and 0.5 in Case 2. Each configuration used 4000 injected particles for diameters of 10, 40, and 60 μm.
Table 5.
Particle–wall restitution coefficients used in the wall-interaction sensitivity assessment.
In Case 2, the absorption coefficient was set to 0.5, and the perpendicular and parallel res-titution coefficients were both set to 0.5. Particles absorbed at the wall were classified as deposited, whereas particles undergoing rebound continued to be tracked until deposi-tion, escape, or termination of the tracking calculation.
The alternative wall treatment reduced deposition efficiency for all three diameters, as shown in Table 6. For 10 μm particles, efficiency decreased from 54.05% to 39.50%, representing a reduction of 14.55 percentage points and a relative decrease of 26.92%. For 40 μm particles, efficiency decreased from 12.40% to 6.60%, corresponding to 5.80 percentage points and 46.77%. For 60 μm particles, efficiency decreased from 57.75% to 54.91%, corresponding to 2.84 percentage points and 4.92%. The largest absolute reduction occurred for 10 μm particles, whereas the largest relative reduction occurred for 40 μm particles. These results demonstrate that the predicted deposition efficiencies depend appreciably on the specified particle–wall interaction treatment.
Table 6.
Effect of particle–wall interaction treatment on deposition efficiency.
3.3. Particle Deposition Efficiency
The particle deposition efficiency, η, is defined as the ratio of the number of particles deposited on the channel walls to the total number of particles injected into the computational domain, expressed as a percentage:
where Ndeposited denotes the total number of particles captured by the upper and lower walls, and Ninjected represents the total number of particles released into the computational domain. This definition assumes equal statistical weights for the injected computational particles and provides a consistent quantitative measure for comparing deposition behavior across the investigated Reynolds numbers and particle diameters.
Figure 10 presents particle deposition efficiency, η, as a function of particle diameter across the three flow regimes. In the laminar regime (Figure 10a), deposition efficiency remains approximately 81–85% for diameters below 35 μm, followed by a Reynolds-number-dependent decline. At Re = 1000, efficiency decreases sharply between 40 and 60 μm, approaching 51% above 70 μm. At Re = 750 and 500, the decline occurs at larger diameters, reaching approximately 51% and 63%, respectively, at 100 μm. Consequently, the Reynolds-number ordering reverses with increasing particle diameter. The transitional regime (Figure 10b) exhibits pronounced nonmonotonic behavior. At Re = 1500, efficiency decreases from 65% to 23–24% between 55 and 70 μm before recovering to 51% at 100 μm. At Re = 3000, efficiency decreases from approximately 54% to 12% at 30–40 μm, recovers to nearly 58% at 60 μm, and exhibits a secondary minimum of 24% near 75 μm. At Re = 5000, the principal minimum reaches 20% near 20 μm, followed by a peak of 59% near 35 μm and a secondary minimum of 42% near 50 μm. In the turbulent regime (Figure 10c), deposition efficiency remains approximately 54–59%, with a maximum of 59.2% near 20 μm at Re = 7000 and no consistent Reynolds-number ordering. The transitional regime exhibits the strongest diameter dependence, whereas the turbulent regime exhibits the weakest. The observed deposition minima and subsequent recoveries may reflect competing effects of particle inertia, gravitational settling, and separated-flow transport. These mechanisms are examined further through spatial deposition distributions, particle trajectories, and residence times.
Figure 10.
Particle deposition efficiency as a function of particle diameter.
3.4. Influence of Particle Stokes Number on Deposition Efficiency
To further investigate the influence of particle inertia on deposition behavior, the deposition efficiency was examined as a function of the step-based Stokes number for three representative Reynolds numbers, Re = 750, 3000, and 7000, corresponding to the laminar, transitional, and turbulent flow regimes, respectively. The Stokes number was calculated as
where τp is the characteristic particle relaxation time, U0 is the reference inlet velocity, and h is the step height.
Figure 11 presents the variation in deposition efficiency with step-based Stokes number for three representative Reynolds numbers, Re = 750, 3000, and 7000, corresponding to the laminar, transitional, and turbulent flow regimes, respectively. The results reveal distinct nonmonotonic deposition trends, indicating that the relationship between particle inertia and deposition depends on Reynolds number. At Re = 750, deposition efficiency initially decreases with increasing Stokes number before recovering at larger values. At Re = 3000, deposition efficiencies of 54.05%, 12.40%, and 57.75% are obtained for particle diameters of 10, 40, and 60 μm, respectively, corresponding to step-based Stokes numbers of approximately 0.36, 5.77, and 12.98. The pronounced minimum at the intermediate Stokes number, followed by substantial recovery at the larger value, demonstrates the nonmonotonic dependence of deposition efficiency on particle inertia under the investigated transitional conditions. At Re = 7000, deposition efficiency exhibits comparatively smaller variations and remains close to 57% over much of the larger- Stokes-number range. These findings demonstrate that Stokes number alone does not provide a universal description of deposition efficiency across the investigated Reynolds numbers. Instead, the observed variations are consistent with the combined influence of particle inertial response and the Reynolds-number-dependent structure of the separated carrier flow. In particular, the pronounced minimum and subsequent recovery at Re = 3000 suggest that changes in particle inertia may modify transport pathways and the likelihood of particles approaching or avoiding deposition surfaces. However, the step-based Stokes number provides a global measure of particle inertial response and does not independently identify the local transport mechanisms responsible for the observed deposition trends.
Figure 11.
Variation in particle deposition efficiency with step-based Stokes number.
3.5. Spatial Particle Deposition Distributions
Figure 12 compares the spatial deposition distributions for Re = 750, 3000, and 7000 using the time-integrated wall mass flow density, whose absolute magnitude represents the deposited mass per unit wall area. At Re = 750, smaller particles (10 and 40 μm) exhibit elongated deposition bands, whereas larger particles produce broader downstream distributions. At Re = 3000, deposition shifts from localized accumulation for 10 μm particles to sparse downstream deposition for 40 μm particles, consistent with the pronounced minimum in deposition efficiency. Deposition becomes more extensive for 60 and 90 μm particles. At Re = 7000, increasing particle diameter redistributes deposition farther downstream despite relatively stable global deposition efficiencies (54–59%). These observations suggest that particle inertia and separated-flow dynamics influence the spatial organization of wall accumulation, demonstrating that global deposition efficiency alone is insufficient to characterize particle deposition.
Figure 12.
Spatial distributions of time-integrated wall mass flow density for different particle diameters and Reynolds numbers.
The corresponding spatial distributions of time-integrated wall mass flow density for Re = 500, 1000, 1500, 5000, 6000, and 8000 are presented in Figures S37 and S38 of the Supplementary Materials, extending the spatial deposition analysis to all nine investigated Reynolds numbers.
3.6. Particle Trajectories and Traveling-Time Distributions
Figure 13 presents particle trajectories colored by elapsed traveling time for representative laminar, transitional, and turbulent flows. Across the three regimes, smaller particles exhibit greater trajectory redistribution near the step expansion, whereas larger particles generally maintain greater streamwise alignment, consistent with their increased inertial response time.
Figure 13.
Particle trajectories colored by elapsed traveling time for different particle diameters and Reynolds numbers.
At Re = 750, localized trajectory deviations are particularly evident for 10 and 40 μm particles. At Re = 3000, the predominantly streamwise transport of 40 μm particles downstream of the expansion provides additional context for the pronounced deposition minimum. At Re = 7000, 90 μm particles exhibit longer traveling times along portions of their trajectories despite their greater directional persistence.
These observations suggest that particle inertia influences both transport pathways and elapsed traveling times. Together with the spatial deposition distributions, the results demonstrate that similar global deposition efficiencies can correspond to different particle transport characteristics. Quantitative comparisons of residence times would require analysis of the complete particle population.
Additional particle trajectories colored by elapsed traveling time for Re = 500, 1000, 1500, 5000, 6000, and 8000 are provided in Figures S39 and S40 of the Supplementary Materials, complementing the representative particle-transport pathways presented in Figure 13.
3.7. Particle Interactions with Carrier-Flow Velocity Fields
Figure 14, Figure 15 and Figure 16 present particle trajectories superimposed on velocity magnitude contours for representative laminar, transitional, and turbulent flows. Across the three regimes, particle redistribution occurs primarily near the separated shear layer. Smaller particles exhibit greater trajectory curvature and lateral spreading, whereas larger particles generally maintain greater streamwise alignment, consistent with their longer aerodynamic response times [35].
Figure 14.
Particle trajectories superimposed on carrier-flow velocity magnitude contours; Re = 750.
Figure 15.
Particle trajectories superimposed on carrier-flow velocity magnitude contours; Re = 3000.
Figure 16.
Particle trajectories superimposed on carrier-flow velocity magnitude contours; Re = 7000.
At Re = 3000, the predominantly downstream-oriented trajectories of 40 and 60 μm particles coexist with substantially different deposition efficiencies. In the turbulent regime, particle-size-dependent trajectory variations persist despite relatively stable global deposition efficiencies. These observations suggest that particle inertia and local velocity variations influence transport pathways and wall encounters, although the trajectory overlays alone cannot establish the underlying deposition mechanisms.
The corresponding particle trajectories superimposed on carrier-flow velocity magnitude contours for the remaining six Reynolds-number cases are presented in Figures S41–S46 of the Supplementary Materials, providing additional visualization of particle transport pathways across the investigated flow regimes.
3.8. Particle Interactions with Vorticity Fields
Figure 17, Figure 18 and Figure 19 illustrate particle trajectories superimposed on spanwise vorticity contours at Re = 750, 3000, and 7000. At Re = 750, smaller particles exhibit trajectory curvature near the separated shear layer. At Re = 3000 and 7000, 10 μm particles undergo noticeable redistribution near the expansion, whereas larger particles maintain greater streamwise alignment. These observations are consistent with particle-inertia-dependent responses to the separated flow and complement the velocity-field analysis. The spatial overlap with vorticity-rich regions provides qualitative insight into particle transport pathways but does not establish causal interactions.
Figure 17.
Particle trajectories superimposed on spanwise vorticity contours; Re = 750.
Figure 18.
Particle trajectories superimposed on spanwise vorticity contours; Re = 3000.
Figure 19.
Particle trajectories superimposed on spanwise vorticity contours; Re = 7000.
Additional particle trajectories superimposed on instantaneous spanwise-vorticity contours for the remaining six Reynolds-number cases are presented in Figures S47–S52 of the Supplementary Materials, complementing the analysis of particle transport through the separated shear layer and vortical flow regions.
4. Discussion
4.1. Influence of Reynolds Number on Separated-Flow Development
The Reynolds-number-dependent development of the separated shear layer, recirculation region, and downstream velocity redistribution establishes distinct transport environments for particles [29,30,31,32,33,34]. Variations in local velocity, flow curvature, and near-wall transport may influence particle trajectories and wall encounters, depending on particle inertia. However, increasing carrier-flow complexity does not necessarily produce higher deposition efficiency. Consequently, the carrier-flow characteristics provide a physical basis for interpreting particle-size-dependent deposition rather than a direct quantitative prediction of the deposited fraction.
4.2. Reynolds-Number and Particle-Size Dependence of Deposition Efficiency
The deposition-efficiency results presented in Figure 10 demonstrate distinct particle-size-dependent responses across the investigated flow regimes. In the laminar cases (Figure 10a), deposition efficiencies remain approximately 81–85% for smaller particles and generally decrease beyond Reynolds-number-dependent particle diameters. The relative ordering of the Reynolds-number cases also varies with particle size.
The transitional cases (Figure 10b) exhibit the most pronounced nonmonotonic behavior. At Re = 1500, deposition efficiency decreases to approximately 23–24% at intermediate particle diameters before recovering. At Re = 3000, the predicted deposition efficiencies for 10, 40, and 60 μm particles are 54.05%, 12.40%, and 57.75%, respectively, corresponding to step-based Stokes numbers of approximately 0.36, 5.77, and 12.98. The pronounced minimum at the intermediate Stokes number and subsequent recovery demonstrate that deposition efficiency cannot be described by a simple monotonic relationship with particle inertia. The Re = 5000 case also exhibits alternating decreases and recoveries, further emphasizing the sensitivity of transitional deposition to particle diameter. These trends may result from the combined influences of particle inertia, transport through the separated shear layer, and particle access to wall-directed trajectories. Increasing particle diameter modifies the response to local carrier-flow variations, potentially affecting wall encounters and downstream escape. However, the relative contributions of these processes have not been independently quantified, and the proposed mechanisms remain physically plausible interpretations rather than established causal explanations. In contrast, the turbulent cases (Figure 10c) exhibit deposition efficiencies within a comparatively narrow range of approximately 54–59%. Nevertheless, similar global deposition efficiencies do not imply identical transport pathways or deposition locations.
Previous investigations provide useful context for interpreting these findings. Ruck and Makiola [11] experimentally demonstrated particle-size-dependent velocity responses downstream of a backward-facing step, emphasizing the influence of particle inertia. Lu and Zhang [19] showed that backward-facing-step geometry and expansion ratio affect deposition behavior and particle-depleted regions. The present study extends these observations by systematically comparing particle-size-dependent deposition across laminar, transitional, and turbulent regimes within a common numerical framework. Differences in geometry, particle properties, injection conditions, and modeling approaches, however, limit direct quantitative comparisons.
4.3. Spatial Deposition, Particle Trajectories, and Traveling Times
The spatial deposition distributions in Figure 12 complement the global deposition-efficiency results by identifying where particles accumulate along the downstream wall. In the laminar regime, Re = 750 (Figure 12a), smaller particles generally produce relatively concentrated, streamwise-elongated deposition regions, whereas larger particles exhibit more dispersed patterns. In the transitional regime, Re = 3000 (Figure 12b), localized concentrations and relatively sparse deposition regions accompany the pronounced nonmonotonic deposition-efficiency trends. In the turbulent regime, Re = 7000 (Figure 12c), diameter-dependent spatial deposition patterns remain evident despite the comparatively weak dependence of global deposition efficiency on particle diameter. The particle trajectories colored by traveling time (Figure 13) reveal diameter-dependent differences in transport pathways and elapsed particle travel times. Additional Reynolds-number cases are presented in Figures S39 and S40. These visualizations provide qualitative information about particle deflection and downstream transport through the separated flow.
The displayed traveling times characterize elapsed motion along individual trajectories rather than residence-time statistics for the complete injected particle population. Moreover, longer traveling times do not necessarily imply greater deposition probability. Together, the deposition-efficiency curves, spatial deposition distributions, and particle trajectories provide complementary descriptions of the deposited fraction, deposition locations, and particle transport histories.
4.4. Interpretation of Velocity and Vorticity Interactions
The particle trajectories superimposed on velocity-magnitude fields (Figure 14, Figure 15 and Figure 16) and spanwise-vorticity fields (Figure 17, Figure 18 and Figure 19) reveal diameter-dependent differences in particle pathways through the separated flow. Smaller particles generally exhibit greater directional changes near the separated shear layer, whereas larger particles often maintain greater directional persistence, consistent with their increased inertia. These differences provide qualitative context for the pronounced deposition-efficiency minima and recoveries observed in the transitional regime. In the turbulent regime, diameter-dependent transport pathways persist despite comparatively stable global deposition efficiencies.
The combined visualizations suggest that particle inertia, recirculation-region transport, and shear-layer interactions may contribute to the observed deposition behavior. However, their individual contributions have not been independently quantified, and the visualizations do not establish a direct causal relationship between individual vortical structures and particle deposition.
4.5. Implications, Validation, and Limitations
The principal contribution of this study is the systematic characterization of particle-size-dependent deposition across nine Reynolds-number cases within a common backward-facing-step geometry and numerical framework. The results demonstrate distinct deposition responses across flow regimes and indicate that global deposition efficiency alone does not fully characterize particle transport and deposition.
The sensitivity assessments presented in Section 3.2.2 demonstrate decreasing particle-number sensitivity for the selected condition and comparatively small absolute changes associated with injection-position perturbations. In contrast, the alternative particle–wall interaction treatment produces substantially larger reductions in deposition efficiency, reaching 14.55 percentage points. Although the deposition-efficiency ordering among the three selected particle diameters is preserved, the robustness of the complete deposition-efficiency curves under alternative wall-interaction assumptions remains unestablished.
Comparisons with experimental velocity measurements support the ability of the LES framework to reproduce principal mean-flow characteristics. However, carrier-flow agreement does not independently establish the quantitative accuracy of particle-deposition predictions. Similarly, the numerical results of Lu and Zhao [35] provide a qualitative benchmark for the nonmonotonic particle-size dependence but not independent experimental validation. Differences in deposition definitions, geometry, particle properties, and numerical methodology limit direct quantitative comparisons.
Additional limitations arise from the adopted particle-force formulation, single-batch injection procedure, wall-interaction assumptions, and statistical sampling. The particle-force model retains aerodynamic drag and gravity while neglecting other forces that may become relevant in regions of strong shear or rapidly varying slip. Furthermore, the cumulative carrier-flow statistics include the initial LES adjustment period; therefore, the averaging-duration sensitivity results do not independently establish fully converged post-transient turbulence statistics. Independent particle-release realizations were not examined.
Consequently, the predicted deposition efficiencies should be interpreted within the investigated numerical framework and prescribed boundary conditions. Future investigations should prioritize independent experimental particle-deposition validation, independent particle-release realizations, and systematic evaluation of alternative particle–wall interaction treatments. Quantitative analyses of particle–fluid slip velocity, residence-time distributions, and deposition and escape statistics would further clarify the mechanisms responsible for the predicted nonmonotonic deposition behavior.
5. Conclusions
This study investigated particle transport and wall deposition downstream of a backward-facing step across laminar, transitional, and turbulent flow regimes. Nine Reynolds numbers, ranging from Re = 500 to 8000, and particle diameters from 10 to 100 μm were examined using a common numerical framework combining large-eddy simulation and Lagrangian particle tracking. The principal conclusions are summarized below.
In the laminar regime, deposition efficiencies remain approximately 81–85% for smaller particles and generally decrease beyond Reynolds-number-dependent particle diameters. The spatial deposition distributions further indicate that the spatial extent of deposition does not necessarily correspond to the overall deposited fraction.
The transitional regime exhibits the strongest particle-size dependence and pronounced nonmonotonic deposition behavior. At Re = 1500, deposition efficiency decreases to approximately 23–24% at intermediate particle diameters before recovering. At Re = 3000, deposition efficiencies of 54.05%, 12.40%, and 57.75% are obtained for particle diameters of 10, 40, and 60 μm, respectively, corresponding to step-based Stokes numbers of approximately 0.36, 5.77, and 12.98. The pronounced minimum at the intermediate Stokes number and subsequent recovery demonstrate that deposition efficiency cannot be described by a simple monotonic relationship with particle inertia. The Re = 5000 case also exhibits nonmonotonic deposition behavior.
In the turbulent regime, deposition efficiencies remain within approximately 54–59% across the investigated particle diameters. Nevertheless, diameter-dependent differences in spatial deposition distributions and particle trajectories indicate that comparable global deposition efficiencies can be associated with different transport pathways and deposition locations.
The combined spatial deposition, trajectory, traveling-time, velocity, and vorticity analyses suggest that particle inertia, recirculation-region transport, and separated shear-layer interactions may contribute to the observed deposition behavior. However, the individual contributions of these mechanisms have not been independently quantified, and the visualizations do not establish direct causal relationships between individual vortical structures and particle deposition.
The numerical sensitivity assessments indicate comparatively small absolute changes associated with particle-number refinement and injection-position perturbations for the investigated conditions. In contrast, the alternative particle–wall interaction treatment produces substantially larger reductions in deposition efficiency, reaching 14.55 percentage points. Although the deposition-efficiency ordering among the three selected particle diameters is preserved, the robustness of the complete nonmonotonic deposition trends under alternative wall-interaction assumptions remains unestablished.
The principal contribution of this investigation is the systematic characterization of particle-size-dependent deposition across three flow regimes within a consistent numerical framework. The pronounced deposition-efficiency minima and subsequent recoveries observed in the transitional regime represent the most distinctive finding. The results indicate that the step-based Stokes number alone is insufficient to characterize deposition across the investigated flow regimes and must be considered together with the Reynolds-number-dependent carrier-flow structure.
The quantitative findings remain conditional on the adopted numerical framework, particle-force formulation, injection conditions, and particle–wall interaction assumptions. Independent experimental validation of particle-deposition efficiencies remains necessary. Furthermore, the single-batch particle-release procedure and statistical sampling limitations restrict the extent to which numerical convergence can be established. Future investigations should prioritize experimental validation, independent particle-release realizations, alternative wall-interaction treatments, and quantitative analyses of particle–fluid slip velocities, residence-time distributions, and deposition and escape statistics.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/dynamics6040055/s1. Additional carrier-flow and particle-transport analyses are provided in the accompanying Supplementary Materials, including instantaneous velocity and spanwise-vorticity fields, modeled turbulence quantities, Reynolds-stress distributions, pressure and skin-friction coefficients, spatial particle-deposition distributions, particle trajectories and traveling times, and particle interactions with carrier-flow velocity and vorticity fields (Sections S.1–S.19; Figures S1–S52).
Funding
This research received no external funding.
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The original contributions presented in this study are included in the article/Supplementary Materials. Further inquiries can be directed to the corresponding author.
Conflicts of Interest
The author declares no conflicts of interest.
References
- Armaly, B.F.; Durst, F.; Pereira, J.C.F.; Schönung, B. Experimental and theoretical investigation of backward-facing step flow. J. Fluid Mech. 1983, 127, 473–496. [Google Scholar] [CrossRef] [Scilit]
- Eaton, J.K.; Johnston, J.P. A review of research on subsonic turbulent flow reattachment. AIAA J. 1981, 19, 1093–1100. [Google Scholar] [CrossRef] [Scilit]
- Driver, D.M.; Seegmiller, H.L. Features of a reattaching turbulent shear layer in divergent channel flow. AIAA J. 1985, 23, 163–171. [Google Scholar] [CrossRef] [Scilit]
- Vogel, J.C.; Eaton, J.K. Combined heat transfer and fluid dynamic measurements downstream of a backward-facing step. J. Heat Transf. 1985, 107, 922–929. [Google Scholar] [CrossRef] [Scilit]
- Chen, L.; Asai, K.; Nonomura, T.; Xi, G.; Liu, T. A review of backward-facing step (BFS) flow mechanisms, heat transfer and control. Therm. Sci. Eng. Prog. 2018, 6, 194–216. [Google Scholar] [CrossRef] [Scilit]
- Jovic, S.; Driver, D.M. Backward-Facing Step Measurements at Low Reynolds Number, Reh = 5000; NASA Technical Memorandum TM-108807; NASA Ames Research Center: Moffett Field, CA, USA, 1994. [Google Scholar]
- Kaiktsis, L.; Karniadakis, G.E.; Orszag, S.A. Onset of three-dimensionality, equilibria, and early transition in flow over a backward-facing step. J. Fluid Mech. 1996, 321, 157–187. [Google Scholar]
- Le, H.; Moin, P.; Kim, J. Direct numerical simulation of turbulent flow over a backward-facing step. J. Fluid Mech. 1997, 330, 349–374. [Google Scholar] [CrossRef] [Scilit]
- Simpson, R.L. Turbulent boundary-layer separation. Annu. Rev. Fluid Mech. 1989, 21, 205–232. [Google Scholar] [CrossRef]
- Nadge, P.M.; Govardhan, R.N. High Reynolds number flow over a backward-facing step: Structure of the mean separation bubble. Exp. Fluids 2014, 55, 1657. [Google Scholar] [CrossRef] [Scilit]
- Ruck, B.; Makiola, B. Particle dispersion in a single-sided backward-facing step flow. Int. J. Multiph. Flow 1988, 14, 787–800. [Google Scholar] [CrossRef] [Scilit]
- Guha, A. Transport and deposition of particles in turbulent and laminar flow. Annu. Rev. Fluid Mech. 2008, 40, 311–341. [Google Scholar] [CrossRef] [Scilit]
- Maxey, M.R.; Riley, J.J. Equation of motion for a small rigid sphere in a nonuniform flow. Phys. Fluids 1983, 26, 883–889. [Google Scholar] [CrossRef] [Scilit]
- Balachandar, S.; Eaton, J.K. Turbulent dispersed multiphase flow. Annu. Rev. Fluid Mech. 2010, 42, 111–133. [Google Scholar] [CrossRef] [Scilit]
- Guha, A. A unified Eulerian theory of turbulent deposition to smooth and rough surfaces. J. Aerosol Sci. 1997, 28, 1517–1537. [Google Scholar] [CrossRef] [Scilit]
- Lai, A.C.K.; Nazaroff, W.W. Modeling indoor particle deposition from turbulent flow onto smooth surfaces. J. Aerosol Sci. 2000, 31, 463–476. [Google Scholar] [CrossRef] [Scilit]
- Elghobashi, S. On predicting particle-laden turbulent flows. Appl. Sci. Res. 1994, 52, 309–329. [Google Scholar] [CrossRef] [Scilit]
- Fessler, J.R.; Eaton, J.K. Turbulence modification by particles in a backward-facing step flow. J. Fluid Mech. 1999, 394, 97–117. [Google Scholar] [CrossRef] [Scilit]
- Lu, H.; Zhang, L.-Z. Particle deposition characteristics and efficiency in duct air flow over a backward-facing step: Analysis of influencing factors. Sustainability 2019, 11, 751. [Google Scholar] [CrossRef] [Scilit]
- Yue, K.; Zhang, X.; Zhang, X.; Zhang, Y. Deposition characteristics of particles in backward-facing step flow and a radiant syngas cooler. Case Stud. Therm. Eng. 2023, 43, 102799. [Google Scholar] [CrossRef] [Scilit]
- Jin, H.; Chen, Y.; Chen, Y.; Wang, C. Numerical simulation of gas–particle dispersion in a backward-facing step flow with LES–FDF model. J. Vis. 2012, 15, 343–352. [Google Scholar] [CrossRef] [Scilit]
- Smagorinsky, J. General circulation experiments with the primitive equations. Mon. Weather Rev. 1963, 91, 99–164. [Google Scholar]
- Germano, M.; Piomelli, U.; Moin, P.; Cabot, W.H. A dynamic subgrid-scale eddy viscosity model. Phys. Fluids A 1991, 3, 1760–1765. [Google Scholar] [CrossRef] [Scilit]
- Piomelli, U. Large-eddy simulation: Achievements and challenges. Prog. Aerosp. Sci. 1999, 35, 335–362. [Google Scholar] [CrossRef] [Scilit]
- Celik, I.B.; Ghia, U.; Roache, P.J.; Freitas, C.J.; Coleman, H.; Raad, P.E. Procedure for estimation and reporting of uncertainty due to discretization in CFD applications. J. Fluids Eng. 2008, 130, 078001. [Google Scholar] [CrossRef] [Scilit]
- Ilie, M. Mach number effect on the aerothermodynamics of transonic and supersonic cavity flows; a computational approach using IDDES. Int. J. Comput. Methods Eng. Sci. Mech. 2026, 27, 19–53. [Google Scholar] [CrossRef] [Scilit]
- Ilie, M. Aerodynamics and aeroacoustics of small-scale HAWT; computational studies using IDDES. Aust. J. Mech. Eng. 2026, 24, 500–532. [Google Scholar] [CrossRef] [Scilit]
- Hu, T.; Wang, C.; Yang, K.; Chen, L. Gravity effect of silica and polystyrene particles on deposition pattern control and particle size distribution on hydrophobic surfaces. J. Ind. Eng. Chem. 2022, 106, 214–224. [Google Scholar] [CrossRef] [Scilit]
- Pont-Vílchez, A.; Trias, F.X.; Gorobets, A.; Oliva, A. Direct numerical simulation of backward-facing step flow at Re = 395 and expansion ratio 2. J. Fluid Mech. 2019, 863, 341–363. [Google Scholar]
- Schafer, F.; Breuer, M.; Durst, F. The dynamics of the transitional flow over a backward-facing step. J. Fluid Mech. 2009, 623, 85–119. [Google Scholar] [CrossRef] [Scilit]
- Blackburn, H.M.; Barkley, D.; Sherwin, S.J. Convective instability and transient growth in flow over a backward-facing step. J. Fluid Mech. 2008, 603, 271–304. [Google Scholar] [CrossRef] [Scilit]
- Rani, H.P.; Sheu, T.; Tsai, E. Eddy structures in a transitional backward-facing step flow. J. Fluid Mech. 2007, 588, 43–58. [Google Scholar] [CrossRef] [Scilit]
- Mantic-Lugo, V.; Gallaire, F. Self-consistent model for the saturation mechanism of the response to harmonic forcing in the backward-facing step flow. J. Fluid Mech. 2016, 793, 777–797. [Google Scholar] [CrossRef] [Scilit]
- Barkley, D.; Gabriela, M.; Gomes, M.; Henderson, R. Three-dimensional instability in flow over a backward-facing step. J. Fluid Mech. 2002, 473, 167–190. [Google Scholar] [CrossRef] [Scilit]
- Lu, H.; Zhao, W. Numerical study of particle deposition in turbulent duct flow with a forward- or backward-facing step. Fuel 2018, 234, 189–198. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.