Skip to Content
BioengineeringBioengineering
  • Article
  • Open Access

26 November 2026

26 Pages

From Extracellular-Space Compression to Extracranial Electromagnetic Response: Multiscale Forward Modeling of Ischemia-Associated Tissue Change

,
,
,
and
School of Automation, Central South University, Changsha 410083, China
*
Author to whom correspondence should be addressed.
This article belongs to the Section Biosignal Processing

Abstract

This study aimed to determine how extracellular-space (ECS) compression affects effective conductivity and a specified extracranial electromagnetic response, and which conclusions depend on compartment electrical properties. Membrane-separated representative volume elements (RVEs) linked physiology-motivated ECS states to effective material spectra. Equal relative perturbations compared ECS fraction and bottleneck geometry at a common baseline. A conductivity factorial and membrane-parameter checks tested structural-response reversal. Normalized benchmark modulation was conditionally multiplied into independent tissue properties in a COMSOL Multiphysics 6.4 layered-head model, with unchanged lesion permittivity. Targeted direct 5 MHz RVE solutions checked interpolation. Independent spherical reference solutions assessed baseline coupling. At ϕ 0 = 0.10 , κ 0 = 0.60 and ± 50 % perturbations, | S ϕ | / | S κ | was 14.99, 7.66 and 4.67 at 100 kHz, 1 MHz and 3 MHz; the signed bottleneck sensitivity was negative at 1, 3 and 10 MHz. Compression did not universally reduce conductivity: with σ i = 1 and σ e = 0.75   S m − 1 , the 10 MHz matched structural change was positive, whereas reducing membrane capacitance to 75% of baseline changed its sign. The independent layered-sphere secondary response differed from COMSOL by 0.321% at 5 MHz. The largest sampled nominal external perturbation was 1.5539 × 10 − 9 at 3 MHz. The directly updated 5 MHz reference gave 1.4091 × 10 − 9 , or 0.211 pV on a 149.5 μV baseline. The structure-derived and constant-decrement predictions had different spectra. Complete spectra for five microscopic states also showed opposite 10 MHz phase directions and different largest sampled frequencies under fixed macro normal properties. ECS fraction was the more influential coordinate in the tested matched comparison, but the direction of structural conductivity change depended jointly on compartment contrast and membrane coupling. The conditional multiscale prescription preserves spectral information absent from a constant decrement, while its extracranial prediction depends on microscopic electrical state; biological transfer and experimental detectability remain unestablished.

1. Introduction

Ischemia-associated extracellular-space (ECS) compression provides a structural starting point for understanding changes in brain-tissue electromagnetic properties. ECS volume and transport are central to the tissue environment [1], while cellular swelling forms part of the coupled processes underlying ischemic oedema [2]. In rat hippocampal and cortical slices, Perez-Pinzon et al. [3] reported region-dependent reductions in extracellular volume fraction during ischemia. These observations connect the physiological problem to a physical one: changing extracellular occupancy changes the spatial organization of conductive medium around membrane-separated cells. For a model in which local tissue volume is fixed, increased cellular occupancy necessarily reduces the available extracellular volume. That structural description is more specific than assigning a bulk conductivity change, but it does not itself determine the corresponding material spectrum. The relevant question is how an ECS change alters effective electromagnetic properties and how that change subsequently contributes to an observable defined outside the head. Addressing this connection requires the structural input, material response and external forward problem to remain distinguishable.
Frequency is central to this connection because the electrical roles of bulk compartments and membrane interfaces differ. Single-shell dielectric modeling distinguishes membrane and bulk contributions [4]. In a membrane-separated model, conductive and capacitive pathways jointly determine the effective response, so the same geometric change need not produce the same relative contrast at every frequency. The literature survey and broadband measurements of Gabriel et al. [5,6] and the dispersive dielectric descriptions of Gabriel et al. [7] provide a frequency-dependent reference for bulk tissue properties, but an independent structural calculation is needed to specify the contrast attributed to a controlled ECS perturbation. Two geometric questions then arise. A reduction in extracellular fraction changes the amount of available conductive space, whereas a change in arrangement or local bottleneck geometry can alter pathways at the same fraction. Distinguishing those contributions is necessary to identify a useful structural coordinate and to avoid treating all geometric detail as equally influential in the material relation.
External inductive responses to brain-related material changes have already been investigated. Numerical magnetic induction models provide established forward approaches [8], including cerebral haemorrhage modeling [9]; electromagnetic phase-shift spectroscopy has also addressed brain oedema and haematoma [10]. González et al. [11] reported rat experiments and associated modeling of inductive phase changes, using prescribed bulk tissue-property changes in the forward calculation. Such a prescription addresses how an assumed material perturbation affects an external quantity and is appropriate to that feasibility question. It does not, by itself, determine the microstructural origin of the imposed perturbation. The missing link addressed here is not whether an externally induced response can exist, but how a controlled ischemia-associated structural variable can be translated into a frequency-dependent material perturbation and then propagated through a specified external forward problem. This distinction places the contribution in the physical relationship between scales. It does not require claiming a new sensing instrument, reproducing the earlier experiment, or assigning a comparative accuracy to two models without a common experimental reference.
Analytical head-field methods already provide efficient solutions for controlled geometries. Liu and Crozier [12] developed Debye-potential solutions for circular-loop excitation and dyadic Green’s-function solutions for more general coil sources in a lossy multilayer sphere. Such methods make interface matching and material dependence explicit and provide valuable independent references. Their concentric-layer abstraction does not reproduce full anatomy. Finite elements accommodate localized material changes and geometric extensions, at the cost of discretization and finite-domain errors. The present work uses both roles: COMSOL for the selected lesion problem and an independently implemented spherical expansion for the concentric baseline. It does not introduce a new general electromagnetic or Green’s-function solver.
Compartment properties are a separate source of uncertainty from geometry. Cell measurements using dielectrophoresis constrain selected cytoplasmic and membrane parameters in specific preparations [13], while intracellular/extracellular impedance measurements at 1–10 kHz demonstrate preparation-dependent frequency behavior [14]. Ex vivo rabbit brain spectra extend bulk normal–pathological comparisons to 1 MHz [15]; they do not identify a matched set of acute-ischemia compartment properties for the present RVEs. Consequently, structural sensitivities require common perturbation sizes, and a conductivity reduction under one benchmark state cannot be assumed to persist under every electrical state.
This study adds three connected elements to fixed-property inductive models and analytical layered-head solutions. First, explicit membrane-separated RVEs quantify the structure-to-property relation, using equal relative perturbations of ECS fraction and bottleneck geometry and separate area-preserving arrangement checks. Second, a normalized structural modulation is conditionally transferred to an independent macro tissue reference and propagated to a defined complex receiver quantity. Third, the resulting spectrum is compared with a constant conductivity decrement, while a staged electrical-parameter analysis tests when the structural conductivity direction changes. These contributions concern a traceable relationship between scales. The transfer is a prescribed hypothesis rather than an experimentally calibrated ischemia-specific constitutive law; the external prediction is a forward calculation rather than a validated diagnostic instrument (Figure 1).
Figure 1. Evidence identities in the prescribed multiscale connection. (A) Measured structural evidence: independent regional normal–ischemia ECS anchors, CA3 0.20→0.17, cortex 0.18→0.09 and CA1 0.14→0.05 [3]. They are separate pairs, not a temporal or severity sequence. (B) Model-derived structural abstraction: cellular occupancy P = 1 − ϕ and the fixed-volume/fixed-effective-cell-number transformations V / V 0 = P / P 0 and R R 0 = P P 0 1 / 3 , implemented as controlled connected-ECS geometries. (C) Benchmark electromagnetic model: membrane-separated RVEs yield normalized structural modulation under fixed E 0 ; these are not measured acute-ischemia compartment properties. (D) Independent macro reference: IT’IS/Gabriel Grey Matter, CSF, cortical bone and scalp/Skin Dry supply absolute frequency-dependent conductivity and permittivity. (E) Forward response: benchmark modulation is conditionally multiplied into macro conductivity, while lesion permittivity remains at baseline, and the specified head/coil problem yields δ . This phenomenological multiplicative structural perturbation prescription is not a directly calibrated chain from rat slices to real mouse morphology and anatomy.

2. Methods

2.1. Ischemia-Associated ECS Parameterization

The structural input was the extracellular-space volume fraction, ϕ ECS , abbreviated ϕ below. Three independent matched normal–ischemia pairs were taken from rat hippocampal and cortical slice measurements reported by Perez-Pinzon et al. [3]: CA3, 0.20 to 0.17; cortex, 0.18 to 0.09; and CA1, 0.14 to 0.05. Each pair retained its own regional normal reference. They were used as physiological structural anchors, not as successive time points or ordered severity categories. The controlled RVE sweep described below was a parameter study informed by these changes, not a reconstruction of a regional disease course.
Cellular occupancy was defined as P = 1 − ϕ . Under the structural-only assumptions of fixed local tissue volume and fixed effective cell number, the corresponding cellular-volume and equivalent-radius ratios were V cell V cell , 0 = P P 0 and R R 0 = P P 0 1 / 3 . These quantities are model-derived, rather than measured cell sizes. The conversion assigns ECS loss to increased cellular occupancy without macroscopic tissue expansion. Regional matching does not imply longitudinal observation of the same cell or animal; the controlled ϕ = 0.20 to 0.05 span is not the measured CA1 pair. Measured ECS evidence, model-derived geometry, benchmark electrical state and independent macro reference retain separate identities (Figure 1).

2.2. Cellular-Scale Electromagnetic Benchmark

All frequency-domain quantities used the time convention exp ( + j ω t ) , with ω = 2 π f and complex admittivity γ = σ + j ω ε 0 ε r . A single-shell spherical-cell benchmark represented intracellular medium, a thin membrane and extracellular medium. Its normal equivalent radius was 5 μm and membrane thickness was 5 nm. Intracellular and extracellular conductivities were both 1 S m − 1 , with relative permittivities of 80. Membrane conductivity and relative permittivity were 10 − 7   S m − 1 and 5. These fixed inputs defined a mechanism-isolation benchmark; they were not assigned as measured acute-ischemia compartment properties.
Maxwell–Garnett [16], symmetric Bruggeman [17], and a host/inclusion-swapped Maxwell–Garnett comparator were used to examine dependence on the effective-medium formulation. The latter exchanges the host and inclusion roles; it is not a fourth independent classical theory. Markel [18] provides the effective-medium expressions and their theoretical context. The single-shell representation follows the membrane-separated modeling tradition of Pauly and Schwan [4]. Occupancy-only and radius-only changes served as structural diagnostics within this benchmark. They were not interpreted as independently occurring physiological processes. Analytical spectra, limiting-case checks and the full mixing-law expressions are assigned to Supplementary Material; the principal quantitative transfer relation was obtained from explicit RVEs rather than by averaging the analytical predictions.

2.3. Explicit Space-Filling RVE Model

The RVE resolved intracellular and connected extracellular domains within a fixed cubic volume. Its side length was L = [ ( 4 π R 0 3 / 3 ) / 0.80 ] 1 / 3 , approximately 8.6823 μm. The uniform-connected family, denoted A, contained a centred cubic cell with side a = L ( 1 − ϕ ) 1 / 3 . The surrounding ECS remained connected as ϕ changed. The bottleneck family, B, used a cubic core with six axial protrusions. For a core side b, protrusion width w = 0.45 b , and protrusion length ℓ, cellular volume satisfied b 3 + 6 w 2 ℓ = ( 1 − ϕ ) L 3 . The minimum gap was g neck = κ ( L − a ) / 2 , with ℓ = L / 2 − g neck − b / 2 . The bottleneck comparison sampled κ = 0.30, 0.60 and 0.90 at ϕ = 0.05, 0.10, 0.15 and 0.20. Because this construction also changes membrane area, it was designated a bottleneck–geometry perturbation. These geometries are model abstractions, not reconstructions of neurites, cell-type diversity or measured tortuosity.
An additional arrangement comparison used eight identical cubic cells in a domain of side 2 L . Aligned and staggered configurations retained cellular volume, cell shape and total membrane area. Staggering applied alternating transverse offsets of half the single-cell boundary gap without changing the cells themselves. This comparison sampled ϕ = 0.05, 0.10 and 0.20 at 100 kHz, 1 MHz and 3 MHz, respectively. It tested arrangement effects separately from the area changes inherent to family B. Representative geometries appear in Figure 2 and Figure S4.
Figure 2. Benchmark-derived frequency-dependent structural modulation. (A) Uniform-connected RVE geometry and ECS fraction. (B) Effective conductivity versus ϕ at the five directly solved microscopic frequencies 1 kHz, 100 kHz, 1 MHz, 3 MHz and 10 MHz. (C) R σ normalized to ϕ = 0.20 at matching frequency; the ϕ = 0.10 series is 0.49644, 0.77523, 0.88692 and 0.98453 at 100 kHz, 1 MHz, 3 MHz and 10 MHz, respectively. (D) Structural modulation at the head frequency grid, with interpolated microscopic inputs distinguished at 300 kHz, 2 MHz and the remaining 5 MHz states; the ϕ = 0.05 5 MHz ratio uses the targeted direct E0 solutions. In (A), light blue denotes ECS and gray denotes the cell. Colors in (B,C) follow the frequency legend in (B); the 1 kHz and 100 kHz curves nearly overlap at the displayed scale. In (D), filled and open circles denote direct and interpolated RVE inputs, respectively. Nominal σ i = σ e and ε i = ε e ; the high-frequency approach towards unity partly reflects that benchmark. It is not recovery of real ischemic tissue.
For a time-harmonic, linear isotropic bulk compartment with no impressed volumetric current source, charge conservation and Ampere’s law require conservation of total current,
∇ · J tot = ∇ · ( J c + j ω D ) = 0 , J c = σ E , D = ε 0 ε r E .
The local electroquasistatic approximation neglects the inductive part of the microscopic electric field, so that E = − ∇ u . With γ = σ + j ω ε 0 ε r , Equation (1) becomes
∇ · ( γ ∇ u ) = 0 .
This is a source-free complex-admittivity equation, often called Poisson-like because of its divergence-form operator. Within each homogeneous compartment, nonzero constant γ gives ∇ 2 u = 0 . The derivation does not assume that conductive current alone is divergence-free at interfaces or that interfacial free charge vanishes. The distinction between current conservation and constitutive assumptions is essential in quasi-static tissue models [19]; explicitly separated intracellular and extracellular domains also underlie cell-by-cell EMI formulations [20].
The approximation requires harmonic steady state, small-signal linear properties, no active bulk sources, and negligible inductive corrections on the RVE scale. For the benchmark, η = ω μ 0 | γ | L 2 is 5.96 × 10 − 9 at 10 MHz, giving | k | L = η = 7.72 × 10 − 5 . These independently recalculated values support the local scalar-potential approximation, while the head-scale vector-potential equation retains induction and displacement current. The RVE side is about 0.0029 of the 3 mm reference lesion diameter. This scale separation motivates an effective-property description but does not prove that the chosen artificial geometry statistically represents real tissue.
Across a membrane of thickness d m , an approximately uniform normal field gives j n = γ m ( u i − u e ) / d m . In the thin-interface limit,
y m = G m + j ω C m , G m = σ m / d m , C m = ε 0 ε r , m / d m , n · J tot , i = n · J tot , e = j n = y m ( u i − u e ) ,
where the same normal n points from intracellular to extracellular medium. Thus the interface conserves normal total current while allowing a potential jump; it is not a zero-impedance contact or a separately meshed membrane volume. The reduction assumes thickness small relative to local geometry and neglects tangential transport through the membrane layer. Time-harmonic thin-layer analysis supports this construction for suitable smooth geometries [21] but supplies no error bound for these polyhedral corners. Here d m / L = 5.76 × 10 − 4 . At ϕ = 0.05 , d m / g A = 0.0679 ; and, at κ = 0.30 , d m / g neck = 0.226 . The smallest-gap/corner configurations therefore need particular caution: mesh refinement verifies the interface model’s discretization, not its equivalence to a resolved finite-thickness membrane.
The principal boundary conditions were u = 0 on x = 0 , u = 1 mV on x = L , and n · J tot = 0 on the four lateral faces. They represent a longitudinal terminal experiment with no lateral exchange rather than a general periodic homogenization problem. Selected lateral-periodic comparisons tested this choice. The positive terminal admittance Y = I / V drive yielded γ eff = Y L x / A terminal , σ eff = Re γ eff and ε r , eff = Im γ eff / ( ω ε 0 ) . For the single cube, γ eff = Y / L ; larger domains used their actual dimensions. Passive signs, geometry volumes, membrane selections and terminal pairing were checked.
Matched finite sensitivities were defined entirely within family B at ( ϕ 0 , κ 0 ) = ( 0.10 , 0.60 ) . Holding the other coordinate fixed,
S p ( h ) ( f ) = σ B ( p 0 ( 1 + h ) , f ) − σ B ( p 0 ( 1 − h ) , f ) 2 h σ 0 ( f ) , σ 0 ( f ) = σ B ( ϕ 0 , κ 0 , f ) , Q ( h ) = | S ϕ ( h ) | | S κ ( h ) | .
The principal comparison used h = 0.50 : ϕ = 0.05 , 0.15 at κ = 0.60 ; and κ = 0.30 , 0.90 at ϕ = 0.10 . Additional direct geometry solves used h = 0.10 and 0.05. All comparisons retained signs and the same-frequency denominator. These central finite sensitivities are not infinitesimal derivatives or global sensitivity indices. Unequal endpoint/arrangement comparisons are retained only as secondary finite effects in S9.
The microscopic benchmark settings are summarized in Table 1.
Table 1. Reproducibility summary of the microscopic benchmark. Detailed geometry and executable sources are retained in Supplementary S9 and S10.

2.4. Normalized Structural Modulation and Prescribed Cross-Scale Connection

The nominal structural modulation used family A and the benchmark electrical state E 0 :
R σ ( ϕ , f ) = σ eff ( ϕ , f , E 0 ) σ eff ( 0.20 , f , E 0 ) .
The macro-scale connection was a phenomenological multiplicative structural perturbation prescription:
σ lesion , macro ( f ) = σ normal , macro ( f ) R σ ( ϕ , f ) .
Normalization guarantees R σ ( 0.20 , f ) = 1 and hence identity with the independent macro normal reference at that structural state. It does not establish that relative modulation is invariant to electrical state. Dimensionless electrical contrasts, including γ i / γ e and the membrane-to-bulk admittance ratio L ( G m + j ω C m ) / γ e , remain relevant after normalization. The prescription assumes that the benchmark-derived relative structural effect can be used as a conditional multiplicative perturbation of the independent reference. The resulting forward calculation tests the physical consequences of that specified connection, not validated constitutive upscaling or an experimentally calibrated ischemic-brain relation.
Available ϕ knots were 0.05, 0.075, 0.10, 0.125, 0.15, 0.175, 0.20 and 0.25. Direct RVE solutions were available at 1 kHz, 100 kHz, 1 MHz, 3 MHz and 10 MHz. Frozen shape-preserving piecewise cubic Hermite interpolation (PCHIP) was retained along ϕ , without extrapolation outside 0.05–0.25; the normalized ratio was interpolated linearly against logarithmic frequency between solved frequencies. No coefficients were refitted. Microscopic inputs at 300 kHz and 2 MHz remained interpolated. At 5 MHz, direct topology-A E0 solves at ϕ = 0.20 and 0.05 replaced the interpolated ratio for the compressed endpoint: R σ = 0.9107688604 , compared with the historical 0.8815302230. Other 5 MHz structural inputs remain interpolated. The paired reference head calculation was recomputed only for the affected endpoint, with its mesh, air-domain and alternate-factorization checks. Figure 2 distinguishes these direct and interpolated inputs; S10 records the reconciliation.
For the electrical-state comparison, the structural prescription was extended within the same family A as
R σ ( ϕ , f ; E j ) = σ eff ( ϕ , f ; E j ) σ eff ( 0.20 , f ; E j ) , σ lesion , macro , j ( f ) = σ normal , macro ( f ) R σ ( ϕ , f ; E j ) .
Each electrical state therefore used its own uncompressed reference. The original E 0 prescription remained the reference prediction. The independently sourced normal tissue conductivities and permittivities, lesion permittivity, head geometry, excitation and receiver were fixed across E j ; only the lesion conductivity multiplier changed. This is a conditional phenomenological extension without calibration to measured ischemic compartment properties.
For non-direct frequencies, the established electrical-scenario interpolation was retained: both structural endpoints were first divided by the original E 0 , ϕ = 0.20 conductivity at each direct frequency, each branch was interpolated linearly in log f , and the compressed branch was divided by the same state’s uncompressed branch. The common reference cancels at direct knots; at intermediate frequencies this explicit interpolation construction is not equivalent to interpolating absolute conductivities or fitting a new constitutive model. The prior direct E 0 and E3 5 MHz endpoint pairs superseded interpolation there. N9 used its verified strict production-mesh 10 MHz pair, including as the upper interpolation knot. Other 5 MHz inputs remained interpolated. No direct 5 MHz correction was extrapolated to other frequencies (S12).

2.5. Prescribed Electrical Stress Scenarios

Electrical dependence was evaluated using dimensionless stress scenarios because the adopted physiological evidence did not establish matched acute-ischemia values for intracellular conductivity, extracellular conductivity, membrane capacitance and membrane conductance. The reference scenario retained E 0 . Each of the four parameters was then multiplied individually by 0.75 or 1.25, with two additional scenarios applying all lower or all upper multipliers. This gave eleven prescribed scenarios. Membrane capacitance and conductance changes were implemented through membrane permittivity and conductivity at fixed thickness; bulk permittivities and geometry were retained. These prescribed electrical stress scenarios test conditional dependence, not a physiological envelope, probability distribution or confidence interval. They do not demonstrate cross-electrical-state transfer invariance.
Two denominators separated electrical changes from structural changes. The total ratio was R total ( ϕ , f , E ) = σ eff ( ϕ , f , E ) σ eff ( 0.20 , f , E 0 ) . The matched-electrical ratio was R matched ( ϕ , f , E ) = σ eff ( ϕ , f , E ) σ eff ( 0.20 , f , E ) . The former represents the combined change relative to a fixed normal reference; the latter isolates the structural comparison under the same electrical scenario. Material minima and maxima of R total at ϕ = 0.10 and 2, 3 and 5 MHz were propagated through the head model. These discrete endpoint calculations did not define a continuous-parameter response bound. An existing targeted mesh refinement was retained to assess the high-frequency matched-electrical reversal.
A staged topology-A analysis was performed at ϕ = 0.20 and 0.05. A 3 × 3 factorial independently varied σ i and σ e over 0.75, 1.00 and 1.25 S m − 1 , holding both bulk relative permittivities at 80. At ( σ i , σ e ) = ( 1 , 0.75 ) , additional branches used C m / C m 0 = 0.75 , 1.25 and G m / G m 0 = 0.1 , 10 , one parameter at a time. An illustrative stronger-contrast case used ( 0.30 , 1.50 )   S m − 1 and C m / C m 0 = 1.2 . These 14 sets at two structural states and five frequencies supplied 140 new direct frequency solutions. We evaluated C = R matched − 1 and retained both complex contrast groups introduced in Section 2.4. Direct additional frequencies and mesh comparisons bracketed selected crossings (S10). No sparse-grid contour was interpreted as a continuously certified phase boundary.
The ranges have distinct evidential status. The conductivity factorial and conductance factors are benchmark stress tests, not measured acute-ischemia intervals. Zhou et al. [13] inferred neuronal cytoplasmic conductivity 0.75–0.95 S m − 1 and membrane capacitance 0.010–0.012 F m − 2 from dielectrophoresis of mouse hippocampal cells; their glial analysis considered 0.3–0.4 S m − 1 . These provide preparation-specific context for selected orders of magnitude, not support for every factorial endpoint or for the assumed extracellular value. The illustrative C m = 0.010625   F m − 2 lies in that capacitance interval, but the combined case is analyst-selected and retains benchmark bulk permittivity. The intracellular factorial is not identical to the inferred neuronal interval: its 1.00 and 1.25 S m − 1 nodes are stress choices. Extracellular conductivity 0.75–1.25 S m − 1 (1.50 in the illustrative case) and membrane conductance 2–200 S m − 2 are analyst-selected benchmark tests; no verified acute-ischemia interval is assigned to either. No cited study supplies a jointly measured electrical state for these ischemic RVEs. Supplementary S10 records sources, experimental context and this distinction explicitly.
Five representative states were selected from the existing electrical results for complete head spectra at ϕ = 0.05 : E 0 ; E3, with reduced extracellular conductivity; N6, the largest positive 10 MHz matched response among the nine conductivity-grid nodes; N9, with reduced membrane capacitance; and N10, with increased membrane capacitance at the E3 bulk contrast. The conductance branches were not selected for head propagation because their archived 10 MHz responses were nearly indistinguishable from E3. All five used G m = 20   S m − 2 , ε r , i = ε r , e = 80 and the same geometry. Their ( σ i , σ e , C m / C m 0 ) values were ( 1 , 1 , 1 ) , ( 1 , 0.75 , 1 ) , ( 1.25 , 0.75 , 1 ) , ( 1 , 0.75 , 0.75 ) and ( 1 , 0.75 , 1.25 ) , respectively. These are benchmark stress states. Selection spans observed responses and parameter contrasts, not physiological likelihood. The 140 factorial solutions were reused, without new RVE solves. Unavailable ϕ = 0.10 factorial states were marked missing, without substitution from another electrical state.
Mechanistic comparisons retained the complex dimensionless groups
χ ( f ) = σ i + j ω ε 0 ε r , i σ e + j ω ε 0 ε r , e , Λ m ( f ) = L ( G m + j ω C m ) σ e + j ω ε 0 ε r , e ,
with the existing L = 8.682328464 μm and exp ( + j ω t ) convention. Both γ e and L y m have units S m − 1 . Real and imaginary parts, magnitudes and phases were tabulated; the mechanism map uses direct RVE points and does not fit a continuous reversal boundary (S13).

2.6. Independent Macro-Scale Tissue Properties

Macro-scale conductivity and relative permittivity were obtained together from the IT’IS Tissue Properties Database V5.0 frequency-dependent dielectric model [22], based on Gabriel et al. [7]. The main homogeneous brain reference was Brain (Grey Matter). The verified source mappings were Scalp to Skin (Dry), Skull (Cortical) to Bone (Cortical), and Cerebrospinal Fluid to its direct dielectric model. Brain (White Matter) was retained only as a separate sensitivity comparator. Neither a generic Brain substitute nor a grey/white average was used. The low-frequency conductivity database was not combined with dielectric-model permittivity. Official source files, mapping records and unit checks were retained with the processed properties.
For the nominal lesion, σ lesion ( f ) = σ normal , macro ( f ) R σ ( ϕ , f ) , whereas ε r , lesion ( f ) = ε r , normal , macro ( f ) . The earlier discrete stress endpoints used R total in place of R σ ; the complete electrical-state spectra in Section 3.6 instead used the same-state ratio in Equation (7). This is a controlled conductivity-component experiment, not a complete complex-admittivity model of ischemia. The independent macro reference fixes the absolute normal material system; it does not calibrate the benchmark compartment parameters. R ε was not assumed equal to R σ . At 3 MHz, a separate sensitivity applied the independently extracted RVE permittivity ratio to the lesion, and another substituted the White Matter baseline. Both retained the reference lesion geometry and ϕ = 0.10. These checks evaluated distinct material assumptions at a representative frequency rather than defining the main model.

2.7. Reference Head-Scale Forward Model

The generic reference small-animal head comprised the concentric spherical brain, CSF, skull and scalp regions, with outer radii of 6.0, 6.3, 6.7 and 7.2 mm, respectively (Figure 3). These were analyst-selected reference dimensions, not atlas-derived anatomy. Spherical lesions lay on the positive z axis, with centroid z = R brain − depth . Depth was measured from the centroid to the brain surface. The main configuration used diameter 3 mm and depth 1.5 mm. Size comparisons used diameters 1, 2 and 3 mm at that depth; depth comparisons used 1.5, 3 and 5 mm at diameter 3 mm. Containment required | R brain − depth | + diameter / 2 ≤ R brain . Non-contained combinations were excluded without clipping or relocation, and the tangent reference geometry received geometry and mesh checks.
Figure 3. Reference forward geometry and existing total fields. (A) Generic concentric reference head with brain/CSF/skull/scalp radii 6.0/6.3/6.7/7.2 mm. (B) Non-optimized coaxial loops of radius 7.2 mm at z = −10/+10 mm, transmitter current 0.010 A; the on-axis reference lesion has D = 3 mm and centroid depth 1.5 mm measured from the brain surface to its centre. The sphere is tangent to the brain surface and fully contained. (C) Existing 10 MHz, ϕ = 0.05 lesion-state total magnetic-flux-density magnitude. (D) The corresponding induced conduction current-density magnitude. These are not lesion-induced difference fields, secondary-only fields or 5 MHz maps. Native exported nodes are shown without interpolation; zero conduction-current nodes are masked on the logarithmic color scale. The separate inset in B defines δ = V lesion − V normal V normal on a shared paired mesh. Complex magnitude, phase change and amplitude change remain distinct.
The standard non-optimized coaxial reference configuration used single-turn transmit and receive loops of radius 7.2 mm, centred at z = −10 and +10 mm. The transmitter carried 0.010 A, represented by uniform impressed azimuthal current over a circular cross-section of radius 0.1 mm. The receiver was an ideal non-loading flux loop. All media were nonmagnetic. With exp ( + j ω t ) , the axisymmetric formulation used A = A ϕ e ϕ , E ϕ = − j ω A ϕ and B = ∇ × A . For this azimuthal, nonmagnetic configuration, its governing operator is
∇ × ( μ 0 − 1 ∇ × A ) + ( j ω σ − ω 2 ε 0 ε r ) A = J ext .
It retains both conduction and displacement current; it is not a conductivity-only quasistatic field equation. Quadratic magnetic-vector-potential discretization and the Magnetic Insulation exterior-boundary and Axial Symmetry nodes were verified in the saved model metadata. Magnetic Insulation imposes the exterior tangential-vector-potential condition; regularity requires A ϕ to vanish on the symmetry axis. Material interfaces share the field solution with the usual electromagnetic continuity conditions and no imposed surface-current sheet. Axisymmetry is exact for the selected coaxial/on-axis geometry but does not test off-axis lesion sensitivity. The production air-domain radius was 120 mm. The recorded electrically-small scale check supported the near-field reference treatment without justifying the removal of the displacement current.
Receiver voltage was V RX = − j ω Φ , with Φ = 2 π r RX A ϕ ( r RX , z RX ) . Normal and lesion states shared the same geometric partitions and mesh. Their normalized complex difference was δ = V lesion − V normal V normal . Three quantities were kept distinct: | δ | ; phase change arg ( V lesion / V normal ) ; and relative amplitude change | V lesion | / | V normal | − 1 . Head solutions were evaluated at 100 kHz, 300 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz and 10 MHz. The matched comparator replaced the structural conductivity prescription with σ lesion = 0.90 σ normal , macro , holding geometry, normal properties and lesion permittivity unchanged.

2.8. Numerical Verification

Finite-element calculations used COMSOL Multiphysics 6.4. Microscopic verification included homogeneous-medium recovery, a thin-membrane slab benchmark, geometry-volume checks, mesh refinement, representative-domain size comparisons and selected lateral-boundary comparisons. A spatial-direction check compared orthogonal drives at a specified structural and frequency point; it was not treated as exhaustive anisotropy testing. These checks addressed the extraction procedure and the controlled structural comparisons separately from physiological applicability.
Head-scale verification examined the paired complex perturbation under mesh refinement, air-domain enlargement, transmitter-current scaling and independent direct factorizations using MUMPS and PARDISO. Independent air-coil and homogeneous-sphere reference calculations tested baseline coupling and the secondary response. For the designated 5 MHz reference case, the numerical comparison scale was defined as the maximum absolute difference in δ among the medium/fine mesh, 90/120 mm air-domain and alternate-solver comparisons. This tested convergence-difference estimate was used to assess local numerical resolvability. It was not a global bound and contained no hardware-noise assumption. The main local comparison appears in Table 2; Supplementary S11 reports the current paired voltages and differences; and S7 retains historical records, baseline benchmarks and source metadata. MUMPS was the recorded default direct factorization and PARDISO the alternate direct factorization. The maximum linear residual in the updated paired solves was 3.8 × 10 − 13 ; a configured residual acceptance threshold is distinct from a solver tolerance. The effective solver relative-tolerance value was not explicitly verified from saved model metadata and is not inferred from defaults. This verification follows the need to distinguish forward-model sensitivity from numerical effects in induction calculations [23].
Table 2. Numerical separation of the reference paired response from the tested discretization and domain variations. Absolute changes are magnitudes of complex differences, | δ check − δ reference | ; percentages use the reference | δ | = 1.4090631438175302 × 10 − 9 . These comparisons concern the difference quantity itself, not just the much larger baseline voltage.
An independent layered-sphere reference was implemented for the no-lesion baseline, using radial spherical-Bessel solutions inside each of the four conductive dielectric layers and an unbounded magnetoquasistatic exterior. The continuity of A ϕ and the tangential magnetic field matched the layer coefficients. The exterior basis was normalized at the outer radius, so its scattering coefficient ratio is dimensionless (S11). The radii, frequency-dependent complex properties, coil centres/radii, transmitter current, exp ( + j ω t ) convention and receiver flux definition matched the FEM model. A filament source replaced its finite circular wire section, and exterior vacuum displacement current was omitted in the reference. The implementation was checked against the independent homogeneous-sphere limit and 12/24/32-term truncations. It compares complex receiver A ϕ and voltage at all seven head frequencies; a separately available FEM air run supports a secondary-response comparison at 5 MHz. It does not independently certify a localized lesion or its much smaller differential voltage (S11).
The complete electrical-state comparison added 35 direct lesion head-frequency solutions and seven common normal-reference solutions on the original seven-frequency grid. All used the unchanged saved production mesh (21,952 elements), 120 mm air radius and MUMPS factorization. The newly computed normal voltages agreed with the archived normal reference to within 2.6 × 10 − 14 in relative complex voltage. The maximum relative difference between the reproduced and archived E 0 response magnitudes was 8.3 × 10 − 9 . These reproduction checks do not replace mesh/domain convergence tests for every alternative state. In particular, the existing 5 MHz E 0 numerical separation factor is not assigned to the new spectra.

3. Results

3.1. ECS Compression Produces Frequency-Dependent Conductivity Remodeling

Under fixed benchmark electrical properties, ECS compression reduced effective conductivity in a frequency-dependent manner. For a representative reduction in extracellular-space fraction from 0.20 to 0.10, the normalized conductivity, R σ , was 0.49644 at 100 kHz, 0.77523 at 1 MHz, 0.88692 at 3 MHz and 0.98453 at 10 MHz (Figure 2). Each value used the same-frequency reference at an ECS fraction of 0.20. Thus, the same structural change produced a substantial relative conductivity contrast at the lower end of the head-model frequency range and a ratio approaching unity at its upper end. The structural perturbation could not be represented by a single frequency-independent conductivity decrement.
The nominal material relation remained monotonic across the sampled structural domain, while its curvature depended on frequency. Conductivity increased with ECS fraction at every directly solved RVE frequency. The intermediate structural states therefore formed an ordered family of material responses rather than a contrast defined only at the most compressed endpoint. The existing curve comparisons supported frequency-dependent curvature, with an approximately linear relation at 10 MHz. The interpolated structural relation retained this behavior without requiring a universal polynomial dependence on ECS fraction. Its scientific content lies in the resolved structural and frequency dependence, not in a claim of strong nonlinearity throughout the spectrum.
The controlled structural relation provided a common description without converting distinct regional observations into a disease trajectory. The literature-derived regional pairs motivated the range of ECS changes, whereas the RVE ratios used a common structural reference to isolate the effect of changing extracellular occupancy. These are complementary roles: the former supplied physiological anchors and the latter defined a conditional material relation. The resulting relation describes how effective conductivity changes when structure is varied within the benchmark system. In E 0 , σ i = σ e and ε i = ε e . As membrane capacitive bypass increases, these equal bulk properties become more accessible, reducing the effective distinction between compartments. The approach of R σ towards unity therefore partly reflects this benchmark choice; it does not imply that real ischemic brain returns to normal at high frequency. The next comparison established whether this fraction-dependent response exceeded the corrections introduced by the tested geometric alternatives.

3.2. Matched Perturbations Identify a Conditional Structural-Sensitivity Ranking

Equal relative perturbations within the same bottleneck family supported a larger ECS-fraction sensitivity at the tested baseline. At h = 0.50 , Q was 14.09, 14.99, 7.66, 4.67 and 2.94 at 1 kHz, 100 kHz, 1 MHz, 3 MHz and 10 MHz, respectively (Figure 4, Table 3). Both coordinates use ± 50 % of their own baseline values, one common conductivity denominator, and exactly paired frequencies. These ratios establish a matched finite comparison for family B, not universal dominance over arbitrary geometric features.
Figure 4. Matched dimensionless finite sensitivities in bottleneck family B. All panels use ( ϕ 0 , κ 0 ) = ( 0.10 , 0.60 ) , with the other coordinate fixed. (A) Signed S ϕ ( h ) . (B) Signed S κ ( h ) ; negative high-frequency values are retained. (C) Q ( h ) = | S ϕ ( h ) | / | S κ ( h ) | . Symbols are direct FEM evaluations; joining lines are guides. The h = 0.50 comparison uses existing verified data; h = 0.10 and 0.05 use new geometry solves. Finite-step stability is not a global biological ranking.
Table 3. Matched finite sensitivities at ϕ 0 = 0.10 , κ 0 = 0.60 and h = 0.50 . Conductivity is in S m − 1 ; sensitivities and Q are dimensionless. The four perturbed parameter values are specified in Equation (4) and its accompanying text.
The signed sensitivities add information that an effect-magnitude ratio hides. S ϕ ( 0.50 ) remained positive, whereas S κ ( 0.50 ) changed from positive at 1 and 100 kHz to negative at 1, 3 and 10 MHz. Thus, increasing the bottleneck coordinate did not always increase conductivity. In this family, changing κ also changes membrane area and local current access; it is not an isolated measure of tortuosity. Forty-five additional direct frequency solutions at h = 0.10 and 0.05 retained this sign pattern and Q > 1 at every frequency. Across all three step sizes, Q ranged from 14.09–16.15, 14.99–17.12, 7.00–7.66, 4.26–4.67 and 2.78–3.11 at the five ascending frequencies. Values do not converge monotonically with step size, and changing geometries also changes the mesh. Thus the ranking is stable over the tested finite steps, but differential-derivative convergence is not established (S9).
The area-preserving arrangement comparison remains informative but has no continuous parameter matched to this derivative-like normalization. Its largest absolute correction was 4.9452%, while the largest bottleneck correction relative to family A was 7.0573%. These are retained as explicitly unequal finite effects in S9, with their parameter changes and denominators stated explicitly; they are not normalized sensitivities.

3.3. The Prescribed Cross-Scale Connection Yields a Locally Resolved Reference Response

Conditionally transferring the benchmark-derived normalized modulation to independent macro properties produced a complex-voltage perturbation numerically resolved relative to the tested convergence differences at the verified reference condition. This is the forward consequence of the multiplicative prescription in Section 2.4, not evidence that normalization validates its biological transfer. The conductivity-component experiment retained normal macro permittivity. Reference geometry and field quantities appear in Figure 3; nominal response spectra appear in Figure 5.
Figure 5. Nominal external spectra and numerical checks. (A) Reconciled nominal | δ | : the ϕ = 0.05 5 MHz point uses direct RVE input and equals 1.40906314382 × 10 − 9 . The largest sampled nominal value is 1.55387807595 × 10 − 9 at 3 MHz; this is not an optimized frequency. Other interpolated microscopic inputs retain their status. (B) The updated 5 MHz paired reference response and complex differences under mesh refinement, air-domain change and alternate factorization. Their local separation factor is 164.532855, not SNR or an error bound. (C) Unchanged propagated stress endpoints at ϕ = 0.10 , 2/3/5 MHz, with their original input provenance; the 5 MHz microscopic inputs in this panel remain interpolated. Their largest propagated value, 4.85328497812 × 10 − 9 , is a discrete stress result, not a physiological bound.
The directly evaluated 5 MHz reference at diameter 3 mm, centroid depth 1.5 mm and ϕ = 0.05 gave | δ | = 1.40906314382 × 10 − 9 using direct E0 microscopic solutions. The raw complex voltages gave | V normal | = 149.5145 μV, | Δ V | = 0.210675 pV and a predominantly quadrature perturbation, with phase change 1.40906312752 × 10 − 9 rad. The relative amplitude change, 2.14273 × 10 − 13 , is distinct and was not independently shown to be numerically resolved. The historical interpolated-input result, 1.87077512449 × 10 − 9 , is preserved as a superseded comparison in S11. On the reconciled nominal grid, the largest sampled magnitude is 1.55387807595 × 10 − 9 at 3 MHz and ϕ = 0.05 . This sampled maximum does not inherit the independent paired convergence checks performed at 5 MHz. Neither value establishes an instrument detection limit.
Response/largest tested difference = 164.532855, a local separation factor. It is not an SNR, error bound, confidence ratio or accuracy factor. The reference result is numerically resolved relative to the tested convergence differences at the verified reference condition; this status is not transferred automatically to other sizes or frequencies. S11 supplies the updated paired comparisons; S7 retains the historical interpolation-based records and earlier solver evidence.
Prescribed electrical stress scenarios altered both the material contrast and the propagated response. Among the propagated material endpoints at an ECS fraction of 0.10, the largest response was 4.85328497812 × 10 − 9 at 5 MHz, with the same reference lesion geometry. The corresponding nominal response at that ECS fraction was 1.13165420738 × 10 − 9 . The larger stress result was neither the nominal headline nor a physiological maximum or confidence upper bound. Propagation covered the material extrema at 2, 3 and 5 MHz, not every electrical scenario throughout the spectrum. At the material level, reducing extracellular conductivity to 0.75 of its benchmark value also produced matched-electrical structural reversals at 10 MHz. The compressed endpoint retained a positive conductivity change of approximately 1.909% after the existing mesh refinement. Thus, the nominal structural direction is conditional on the electrical properties, while the demonstrated microstructure-to-external-response connection remains explicitly defined.

3.4. Geometry and Frequency Weighting Distinguish the Prescribed Structural Prediction

The exported external responses increased with lesion size and decreased with centroid depth across the feasible sampled reference configurations. At 3 MHz and an ECS fraction of 0.10, increasing diameter from 2 to 3 mm at a fixed depth of 1.5 mm yielded | δ | values of 1.2297 × 10 − 10 and 9.2823 × 10 − 10 . For the 3 mm lesion, increasing depth from 1.5 to 3 to 5 mm yielded 9.2823 × 10 − 10 , 8.8090 × 10 − 10 and 8.4131 × 10 − 10 , respectively. The sampled ordering was also retained at 2 and 5 MHz (Figure 6). The 1 mm points are retained in S8 as exploratory/not independently numerically certified; the D3 reference comparison is not their certification. These finite scans characterize the reference geometry and do not establish a universal size or depth law.
Figure 6. Sampled geometric trends and spectral comparison with a constant decrement. (A) D2/D3 size comparison at fixed centroid depth 1.5 mm, ϕ = 0.10, and 2/3/5 MHz. (B) D3 centroid-depth comparison at 1.5/3/5 mm. (C) At D3/depth1.5/ ϕ = 0.10, compare the seven-frequency nominal structural prescription and conductivity-only −10% comparator with unchanged lesion permittivity in both. The response-magnitude ratio decreases from 5.035587 at 100 kHz to 0.154677 at 10 MHz; this is a spectral comparison, not an accuracy ranking or full replication of the dual-property González et al. [11] model. (D) RVE-to-comparator response-magnitude ratio at the seven sampled frequencies, decreasing from 5.035587 at 100 kHz to 0.154677 at 10 MHz. The separate 3 MHz White/Grey and independently prescribed permittivity checks are reported in Table S8b; permittivity policy can affect magnitude.
The largest sampled relative material contrast did not coincide with the largest sampled external response. For the same ECS fraction of 0.10 over the common 100 kHz–10 MHz range, | R σ − 1 | was largest at the low-frequency endpoint, whereas the nominal external response reached its largest sampled value at 5 MHz. The comparison holds the lesion state and reference geometry fixed while changing the physical quantity being evaluated. It separates relative material contrast from receiver response and shows why the frequency dependence of the former cannot alone specify the latter. The result identifies a maximum on the tested grid, not an optimized operating frequency.
The constant conductivity-decrement comparator did not reproduce the frequency dependence of the structure-derived prediction. With geometry, normal tissue properties and the unchanged-permittivity policy held constant, and the RVE-to-comparator response-magnitude ratios were 5.035587, 3.705414, 2.247668, 1.542993, 1.130784, 0.716638 and 0.154677 at 100 kHz, 300 kHz, 1 MHz, 2 MHz, 3 MHz, 5 MHz and 10 MHz, respectively. Relative to the nominal RVE prediction, the constant decrement gave lower responses at the lower tested frequencies and higher responses at the upper tested frequencies. A single rescaling could therefore not align the two spectra. At 3 MHz, however, their response ratios were nearly constant across the sampled size and depth combinations, so the distinction was spectral rather than a demonstrated difference in normalized spatial-response shape.
Single-frequency material checks changed the response magnitude without replacing the spectral comparison. At 3 MHz, the White Matter reference produced 0.605715 times the Grey Matter response, and the separate permittivity-transfer sensitivity produced 1.068184 times the principal response. These checks quantify dependence on the absolute reference properties and on an independently specified permittivity contrast at one frequency. In particular, the latter establishes that permittivity policy can affect magnitude, not that permittivity is negligible. The central result is that the external prediction combines geometry-dependent electromagnetic weighting with a structure-derived material spectrum. The normalized structural modulation therefore contributes frequency information that an arbitrary constant conductivity decrement does not retain.

3.5. Structural Reversal Depends Jointly on Bulk Contrast and Membrane Coupling

The factorial separated matched structural reversal from a change in the fixed-reference total ratio (Figure 7). At 10 MHz, compression from ϕ = 0.20 to 0.05 increased conductivity at two of the nine conductivity-grid nodes: ( σ i , σ e ) = ( 1 , 0.75 ) and ( 1.25 , 0.75 )   S m − 1 , with C = + 1.853 % and + 3.536 % . The remaining seven nodes were negative. In particular, ( 1.25 , 1 ) remained negative ( − 0.378 % ), although σ i > σ e . A comparison of the two real conductivities alone therefore does not determine the finite-frequency structural sign.
Figure 7. Electrical conditionality of structural compression, C = σ ( 0.05 , f , E ) / σ ( 0.20 , f , E ) − 1 . (A) Signed 10 MHz conductivity factorial; each labelled node is a direct FEM result, with baseline membrane parameters. (B) Selected direct response spectra. (C) Membrane-capacitance dependence near the high-frequency transition, including additional direct frequency points and selected mesh refinement. (D) Sign-change brackets on the sampled conductivity grid; segments connect opposite-sign nodes and indicate only where a crossing may lie under continuity, not a certified continuous boundary. Bulk relative permittivities remain 80. Connecting curves are visual guides. Open diamonds additionally show the stricter N9 10 MHz production/fine-mesh results; these are distinct from its production-setting curve. All parameter sets, denominators and direct-point status are provided in S10.
At ( 1 , 0.75 ) , changing C m / C m 0 from 0.75 to 1.00 to 1.25 changed the 10 MHz structural response from − 0.135 % to + 1.853 % to + 2.782 % with the production settings. Targeted N9 checks with stationary tolerance 10 − 7 and iterative residual acceptance 10 − 6 gave − 0.175895 % and − 0.175775 % on the production and refined meshes, respectively. The signed difference changed by only 0.000120 percentage points between these stricter solves; their logged linear residuals were at most 1.3 × 10 − 10 . All four mesh/solver combinations remained negative, supporting the N9 sign within these tests, while its magnitude was solver-sensitive under the production settings (S10). In contrast, G m / G m 0 = 0.1 and 10 gave + 1.853 % and + 1.852 % at that frequency. This limited high-frequency conductance dependence does not establish negligible membrane conductance at lower frequencies. The illustrative ( 0.30 , 1.50 ) case with C m / C m 0 = 1.2 remained negative at all five sampled frequencies, including − 29.40 % at 10 MHz. The refined E3 result, + 1.909 % , establishes the persistence of that particular reversal under its mesh change, rather than parameter-universal robustness. Sixteen additional direct frequency solutions at 5, 7, 8 and 9 MHz, including both structural endpoints and both meshes, bracketed the E3 sign change between 7 and 8 MHz on each mesh (S10). No exact transition frequency is inferred.
The two denominators yield different conclusions even at the same electrical point. For ( 1 , 0.75 ) at 10 MHz, R matched = 1.018530 , but R total = 0.963928 : compression raises conductivity relative to the same electrical state’s uncompressed structure while the final conductivity remains below the original E 0 reference. Conversely, a total ratio above unity need not imply a positive structural change. The sparse parameter grid establishes directly simulated positive and negative examples; it neither defines a physiological probability of reversal nor a complete four-parameter phase diagram.
Across the five selected states, the directly solved 100 kHz matched changes were all negative, from − 74.49 % to − 71.80 % . At 10 MHz they separated into − 2.2364 % , + 1.8530 % , + 3.5358 % , − 0.1759 % and + 2.7818 % for E 0 , E3, N6, N9 and N10, respectively, using the strict N9 replacement. The same structural compression thus remained conductivity-reducing for E 0 and N9 but conductivity-increasing for the other three states at that sampled frequency. The distinction is propagated through the fixed macro reference in the following comparison.

3.6. Electrical-State Dependence of the Predicted Extracranial Spectrum

Complete direct head calculations at the original seven frequencies showed that microscopic electrical-state dependence changes the response magnitude, phase direction and spectral shape even when the macro normal material system is fixed (Figure 8). At 10 MHz, the receiver phase changes for E 0 , E3, N6, N9 and N10 were, respectively, + 0.9084 , − 0.7526 , − 1.4361 , + 0.07144 and − 1.1299 nrad. Positive matched conductivity changes in E3, N6 and N10 therefore produced phase changes of the opposite sign to E 0 in this specified geometry. Their 10 MHz magnitudes were 0.7526 , 1.4361 and 1.1299 × 10 − 9 , compared with 0.9084 × 10 − 9 for E 0 and 0.07144 × 10 − 9 for N9. The complex spectral differences, | δ j − δ 0 | / | δ 0 | , were 182.85%, 258.10%, 92.13% and 224.39% for E3, N6, N9 and N10. Values above 100% partly reflect opposite phase directions and should not be read as magnitude increases.
Figure 8. Electrical-state-dependent extracranial spectra with fixed macro normal properties, lesion geometry and coil configuration. (A) | δ j | . (B) Signed phase change arg ( V lesion , j / V normal ) . (C) Relative complex difference 100 | δ j − δ 0 | / | δ 0 | , which includes phase direction. (D) Matched conductivity change 100 C j . Filled circles identify direct RVE inputs; open squares identify interpolated RVE inputs. Every head point is a direct FEM solve. Curves connect the seven original frequency samples without implying additional solutions or certified maxima.
The largest sampled normalized responses were 1.55388 , 1.22873 , 1.43881 , 1.87427 and 1.12990 × 10 − 9 for E 0 , E3, N6, N9 and N10, occurring at 3, 3, 3, 5 and 10 MHz, respectively. N6 at 10 MHz ( 1.43611 × 10 − 9 ) was only 0.187% below its 3 MHz value; this near-tie does not establish a numerically robust peak ordering. N9’s sampled maximum uses interpolated 5 MHz microscopic input. Neither these sampled maxima nor lines between frequency points establish an operating optimum or an independently validated continuous spectrum. The associated voltage differences, relative amplitude changes, input provenance and common normal voltages are reported in S12. The small amplitude changes are retained for traceability without claiming their independent numerical resolution.
Figure 9 organizes the structural response using the two complex contrast groups. At 10 MHz, E3, N9 and N10 share χ = 1.332164 − 0.019711 j , while | Λ m | is 6.42895, 4.82171 and 8.03619, respectively. Their membrane-admittance phases remain close to 80.60°, yet the reduced-capacitance state has a negative structural response and the other two have positive responses. At the same membrane ratio as E3, N6 has χ = 1.664327 − 0.039422 j and the larger positive response. These matched contrasts support a joint mechanism; they do not identify a universal threshold.
Figure 9. Discrete dimensionless mechanism map for the selected topology-A electrical states. (A) Direct RVE samples in log 10 | χ | and log 10 | Λ m | , with color indicating 100 C j and shape indicating frequency. Some coincident markers overlap because bulk properties coincide. In (B), N9 and N10 coincide, with N10 plotted on top; E3 has the same compartment contrast at matching frequencies. (B,C) Phases of the two complex groups preserve information absent from the magnitude map. (D) Signed 10 MHz responses, including the verified strict production-mesh N9 result. The map is a set of calculated conditional examples, without a fitted phase boundary or universal reversal threshold. All complex components are supplied in S13.

3.7. Independent Spherical References Test the Commercial FEM Baseline

Air-coil and homogeneous-sphere comparisons were evaluated from the raw complex outputs and independent quadrature/24-term multipole code. The relative complex-voltage difference for the air coil was 0.6161365%; the homogeneous-sphere secondary-response error was 0.2948769%. The four-layer reference gave a 0.3207% secondary-response error at 5 MHz (Figure 10; full real/imaginary components and absolute differences in S11). Its homogeneous-material limit agreed with the existing independent sphere implementation to within 4.8 × 10 − 9 in relative secondary response over the seven-frequency grid.
Figure 10. Independent reference calculations compared with COMSOL 6.4. (A) Total receiver voltage for the no-lesion four-layer sphere at seven frequencies. (B) Frequency-specific complex total-voltage discrepancy. (C) Distinct 5 MHz benchmark metrics: air total voltage, homogeneous-sphere secondary response and layered-sphere secondary response. Secondary quantities use ( V t i s s u e − V a i r ) / V a i r for each implementation separately. (D) Multipole truncation and homogeneous-limit checks. These comparisons validate specified baseline quantities, not heterogeneous lesion differences or hardware detectability.
The approximately 0.616% total-voltage discrepancy across the grid is dominated by baseline coupling and must not be confused with the smaller relative discrepancy of the material-induced secondary response. The FEM uses a finite wire section and a 120 mm air boundary, whereas the reference uses a filament and unbounded vacuum. The reference also omits exterior vacuum displacement current. These controlled formulation differences, together with discretization and series truncation, prevent attributing all disagreement to one source. The comparison tests complex receiver A ϕ through the same flux-to-voltage relation as the FEM; it is not a full internal-field validation. MUMPS/PARDISO comparisons remain alternate factorizations of the same FEM equations, rather than independent physical benchmarks. None of these baseline errors is an error bar for the lesion-induced differential response.

4. Discussion

4.1. Structural Sensitivity Is Robust Within a Stated Comparison, Not Universal

The matched comparison supports ECS fraction as the more influential coordinate around the tested bottleneck-family baseline, with both parameters perturbed by the same relative amount. This corrects the ambiguity of comparing unequal endpoint effects. The conclusion is local to a specified geometry family, baseline, frequency and finite step; it does not rank ECS against every feature of real tissue. The negative high-frequency bottleneck sensitivity further shows why signs must accompany magnitudes. Membrane area and access to intracellular pathways change with the bottleneck construction, while the separate arrangement comparison preserves membrane area.
The electrical scan places a stronger boundary on the nominal conductivity-reduction mechanism. At low frequencies, membrane impedance restricts intracellular access, so extracellular occupancy strongly affects conduction. Increasing frequency increases capacitive coupling and changes the contribution of intracellular pathways. With unequal compartment admittivities, compression can then raise or lower effective conductivity depending jointly on bulk contrast, membrane admittance and geometry. The dimensionless groups γ i / γ e and L y m / γ e retain those dependencies after normalization. The failure of σ i > σ e alone to predict the sign, and the capacitance-induced sign change, demonstrate that the reversal cannot be reduced to a comparison of two real conductivities. The N9 negative sign persisted with stricter solver settings on both meshes, although its production-setting magnitude was sensitive to the solver tolerance. Existing bulk dissipative-power partitions support increased intracellular participation but do not include membrane dissipation or uniquely identify a causal decomposition.
What persists across the tested analyses is the frequency dependence and conditionality of structural modulation, not a universal negative sign. The positive E3 example survives its mesh refinement; the wider grid also contains negative examples and a capacitance-dependent boundary. The benchmark has equal bulk properties, so its high-frequency approach toward unity is partly built into that electrical choice. Neither this approach nor a positive matched change means physiological recovery. The systematic but sparse scan identifies controlling contrasts and falsifies an unconditional sign claim; it does not establish a physiological reversal region.
The dimensionless comparisons make this mechanism more specific. For E3, | Λ m | rises from 0.06440 at 100 kHz to 6.42895 at 10 MHz: membrane admittance changes from small to large relative to the bulk scale γ e / L . Over the same interval, arg Λ m changes from 89.76° to 80.60°, and χ retains a nonzero negative phase. At weak coupling, the membrane limits exchange with intracellular domains, and connected extracellular pathways can dominate conduction. Stronger capacitive exchange permits intracellular regions to participate more in the effective response; increased intracellular occupancy can then offset or exceed the loss of extracellular pathway volume when the compartment contrast and geometry permit it. The E3–N9–N10 comparison holds χ fixed while varying membrane capacitance, and the E3–N6 comparison holds Λ m fixed while varying intracellular admittivity. Both changes alter C, demonstrating that neither | χ | > 1 nor | Λ m | alone determines the sign. The phases and geometrical connectivity remain part of the boundary-value problem. At 10 MHz, ω C m 0 ≃ 5.56 × 10 5   S m − 2 greatly exceeds the tested G m = 2 –200 S m − 2 , consistent with the weak high-frequency conductance dependence in the archived branches; this argument does not remove conductance effects at low frequency. No new membrane-resolved power partition was computed, so this interpretation rests on controlled parameter contrasts rather than a newly measured or fully decomposed current pathway.

4.2. Why the Strongest Material Contrast Does Not Select the Strongest External Response

Relative material contrast and external receiver response describe different levels of the forward problem. The former measures the change in a local effective property relative to its normal value. The latter depends on the frequency-dependent normal tissue properties, excitation field, induced-current distribution and coupling to the receiver. Lesion volume and position determine which part of that field distribution experiences the altered material relation. Consequently, neither the relative conductivity ratio alone nor its largest departure from unity specifies the external spectrum. The model must propagate that ratio through an absolute reference material system and a defined electromagnetic geometry.
The separation between low-frequency material contrast and the external sampled maximum depends on the structural state and on the accuracy of the microscopic frequency representation. At ϕ = 0.10 , the retained interpolated-input spectrum has its largest sampled response at 5 MHz. At ϕ = 0.05 , direct 5 MHz RVE input reduced the corresponding external response by 24.68%, and the reconciled sampled maximum occurs at 3 MHz. Thus sparse microscopic interpolation can affect even the ordering of external frequency samples. The frequency weighting still combines the material spectrum with induction and receiver coupling, but neither sampled maximum identifies a general operating optimum or a shifted cellular dispersion peak.
The size and depth results express the spatial counterpart of this weighting. The spherical lesions lie on the symmetry axis, where azimuthal electric-field weighting is non-uniform and vanishes at the axis by regularity. Enlarging an on-axis lesion changes both the perturbed volume and the region over which the field is sampled; moving its centroid changes its coupling to the fixed transmit–receive geometry. The observed monotonic sampled trends are consistent with this dependence. Size response therefore cannot be interpreted from volume alone. These results do not represent arbitrary off-axis lesions and do not imply proportionality to volume or a universal attenuation exponent. Retaining the uncertified smallest-lesion outputs as marked exploratory points preserves the information in the finite scan without assigning them the numerical status of the verified reference response. Thus, spatial and spectral weighting form a common explanation for why a local material contrast needs a head-scale forward calculation.
The five complete spectra now show how electrical conditionality propagates beyond the RVE. The independently sourced macro normal conductivity and both normal and lesion permittivity were identical across comparisons, while each state’s own ϕ = 0.20 denominator defined its structural multiplier. Consequently, the observed magnitude and phase differences arise from changing that microscopic modulation within the specified head problem. Normalization enforces identity at ϕ = 0.20 but does not make the ratio electrically state-invariant. A different choice of microscopic state can reverse the predicted phase direction at high frequency or alter the largest sampled frequency. These are alternative conditional predictions, not uncertainty intervals for real ischemic tissue. Sparse microscopic interpolation and the near-tied N6 maxima further limit any interpretation of peak location; independent biological calibration and state-specific numerical verification remain necessary before generalizing these predictions.

4.3. What a Conditional Structural Prescription Adds to Fixed-Property Models

Prescribed bulk property changes provide a useful way to examine how an external electromagnetic measurement responds to a tissue perturbation. González et al. [11] combined rat measurements and modeling of inductive phase changes in brain ischaemia, establishing relevant bulk-response evidence. The present study addresses a different part of the explanation: how a controlled extracellular structural change generates the frequency-dependent property contrast supplied to the external forward model. Its contribution is a traceable, explicitly prescribed connection between these levels, not a new electromagnetic principle or a new claim that brain-related inductive changes can exist. Normalization supplies a reference identity; the conditional multiplicative structural prescription, not a validated constitutive mapping, supplies the cross-scale assumption.
The controlled constant-decrement comparison exposes the information added by this structural origin. A fixed conductivity decrement assigns the same relative material change throughout the spectrum. The RVE-derived relation instead produces a contrast whose magnitude depends jointly on ECS fraction and frequency. Propagating both prescriptions under otherwise matched conditions yielded a frequency-varying response ratio, including a change from ratios above unity to ratios below unity across the tested band. This difference cannot be represented by one multiplicative adjustment to the external spectrum. It supports retaining structure-derived frequency information when interpreting forward predictions, without requiring an accuracy ranking against tissue measurements that were not used as ground truth here.
The present comparator was conductivity-only, with unchanged permittivity in both compared models. The original model described by González et al. [11] reduced both conductivity and permittivity. Accordingly, the current comparison tests a controlled constant-conductivity prescription inspired by the broader fixed-property modeling approach; it is not a full reproduction of that work. This separation keeps the comparison focused on the material relation being investigated. It also explains why the demonstrated spectral difference should not be extended to a claim of different normalized spatial-response shapes, for which the sampled single-frequency comparison did not provide evidence.

4.4. Robust Numerical Findings, Conditional Transfer and Unresolved Detectability

Within the tested numerical framework, the supported findings are a dispersive structural material response, a matched finite-sensitivity ranking at the specified baseline, and a receiver spectrum that differs from a constant conductivity decrement under matched geometry and permittivity policy. These are reproducible model comparisons. The magnitude and sometimes sign of the material change depend on compartment and membrane properties; the external spectrum additionally depends on the multiplicative transfer prescription, independent macro baseline, lesion geometry and coil configuration. The independent layered reference strengthens verification of the concentric baseline, while the paired mesh/domain/solver checks address the reference lesion difference. Neither establishes biological calibration or every untested lesion configuration.
The physiological evidence supplies ECS anchors, not a jointly measured electrical state. Dielectrophoresis parameters from isolated mouse cells, low-frequency neural impedance measurements and ex vivo bulk pathological spectra come from different preparations and frequency ranges [13,14,15]. They cannot be combined into an acute-ischemia confidence interval. Ionic redistribution, depolarization, membrane dysfunction, vascular edema, cell death, perfusion and blood-volume changes can alter structure and electrical properties together. Their coupled time evolution remains outside this structural-only prescription. Measurements of ECS and compartment properties in matched preparations would be needed to test transfer to real tissue.
The nominal 5 MHz calculation predicts a 0.211 pV complex difference on a 149.5 μV receiver baseline, predominantly a phase perturbation of 1.4091 × 10 − 9 rad. The much smaller relative amplitude change is a separate quantity. The factor 164.53 compares the computed complex perturbation with selected numerical differences; it contains no sensor-noise spectrum, bandwidth, coupling drift, positioning uncertainty or interference model. Multifrequency induction hardware requires its own experimental characterization [24]. The present calculation therefore establishes neither practical detectability nor the impossibility of detection. A phantom test with independently measured complex properties, controlled geometry and phase/amplitude noise characterization would be a direct next step, followed by biological validation of the structural prescription.

5. Conclusions

At a common bottleneck-family baseline and matched ± 50 % relative perturbations, ECS fraction produced the larger dimensionless conductivity sensitivity at all five tested frequencies, while the bottleneck sensitivity changed sign. This establishes a conditional structural ranking rather than a comparison of unequal finite changes. A systematic conductivity grid and membrane checks showed that compression-induced conductivity reduction is not universal: high-frequency reversal depends jointly on compartment contrast and membrane coupling, and a positive matched structural change can coexist with a total conductivity below the original reference.
Under the stated multiplicative cross-scale prescription, structure-derived modulation yielded an external spectrum that a constant conductivity decrement did not reproduce. Independent air, homogeneous-sphere and layered-sphere references verified specified baseline quantities; separate paired numerical checks supported the reference complex lesion response. The largest sampled nominal response, 1.5539 × 10 − 9 at 3 MHz, is a conditional forward prediction, not an optimized operating frequency or demonstrated sensor capability. Complete spectra for five existing microscopic electrical states further showed that ECS structure alone does not determine the extracranial prediction: state-dependent structural modulation altered its magnitude, phase direction and sampled frequency ordering under fixed macro normal properties. Matched biological measurements and experimental noise/coupling characterization remain necessary to establish physiological transfer and detectability.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/bioengineering13121447/s1: File S1: Supplementary Materials, comprising Analytical equations, physiological anchors, complete tabulated checks, tissue-property provenance, raw complex voltages and additional geometric and material comparisons (S1–S13), including matched sensitivities, electrical reversal checks, independent layered-sphere references, complete conditional head spectra and complex dimensionless mechanism parameters.

Author Contributions

J.T.: conceptualization; methodology; software; validation; formal analysis; investigation; writing—original draft preparation; review and editing; supervision; funding acquisition; Y.L.: conceptualization; methodology; software; validation; formal analysis; investigation; writing—original draft preparation; S.T.: conceptualization; methodology; software; validation; formal analysis; investigation; W.Y.: conceptualization; methodology; software; validation; formal analysis; investigation; D.X.: conceptualization; methodology; software; validation; formal analysis; investigation; writing—original draft preparation; review and editing; supervision. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Natural Science Foundation of Changsha under Grant kq2502249 and the Science and Technology Program of Hunan provincial Department of Transportation under grant 202501-1.

Data Availability Statement

Data underlying the findings of this study are available from the corresponding author upon reasonable request. The modeling and analysis code supporting this study is available from the corresponding author upon reasonable request. No public deposit or redistribution of commercial software is asserted.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Syková, E.; Nicholson, C. Diffusion in Brain Extracellular Space. Physiol. Rev. 2008, 88, 1277–1340. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Simard, J.M.; Kent, T.A.; Chen, M.; Tarasov, K.V.; Gerzanich, V. Brain oedema in focal ischaemia: Molecular pathophysiology and theoretical implications. Lancet Neurol. 2007, 6, 258–268. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Perez-Pinzon, M.A.; Tao, L.; Nicholson, C. Extracellular potassium, volume fraction, and tortuosity in rat hippocampal CA1, CA3, and cortical slices during ischemia. J. Neurophysiol. 1995, 74, 565–573. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Pauly, H.; Schwan, H.P. Über die Impedanz einer Suspension von kugelförmigen Teilchen mit einer Schale. Z. FüR Naturforschung B 1959, 14, 125–131. [Google Scholar] [CrossRef] [Scilit]
  5. Gabriel, C.; Gabriel, S.; Corthout, E. The dielectric properties of biological tissues: I. Literature survey. Phys. Med. Biol. 1996, 41, 2231–2249. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  6. Gabriel, S.; Lau, R.W.; Gabriel, C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys. Med. Biol. 1996, 41, 2251–2269. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  7. Gabriel, S.; Lau, R.W.; Gabriel, C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys. Med. Biol. 1996, 41, 2271–2293. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Morris, A.; Griffiths, H.; Gough, W. A numerical model for magnetic induction tomographic measurements in biological tissues. Physiol. Meas. 2001, 22, 113–119. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Zolgharni, M.; Ledger, P.D.; Armitage, D.W.; Holder, D.S.; Griffiths, H. Imaging cerebral haemorrhage with magnetic induction tomography: Numerical modeling. Physiol. Meas. 2009, 30, S187–S200. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Gonzalez, C.A.; Valencia, J.A.; Mora, A.; Gonzalez, F.; Velasco, B.; Porras, M.A.; Salgado, J.; Polo, S.M.; Hevia-Montiel, N.; Cordero, S.; et al. Volumetric Electromagnetic Phase-Shift Spectroscopy of Brain Edema and Hematoma. PLoS ONE 2013, 8, e63223. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. González, C.A.; Villanueva, C.; Vera, C.; Flores, O.; Reyes, R.D.; Rubinsky, B. The detection of brain ischaemia in rats by inductive phase shift spectroscopy. Physiol. Meas. 2009, 30, 809–819. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Liu, F.; Crozier, S. Electromagnetic fields inside a lossy, multilayered spherical head phantom excited by MRI coils: Models and methods. Phys. Med. Biol. 2004, 49, 1835–1851. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Zhou, T.; Ming, Y.; Perry, S.F.; Tatic-Lucic, S. Estimation of the physical properties of neurons and glial cells using dielectrophoresis crossover frequency. J. Biol. Phys. 2016, 42, 571–586. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Bedard, C.; Piette, C.; Venance, L.; Destexhe, A. Extracellular and intracellular components of the impedance of neural tissue. Biophys. J. 2022, 121, 869–885. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  15. Yang, L.; Zhang, G.; Song, J.; Dai, M.; Xu, C.; Dong, X.; Fu, F. Ex-Vivo Characterization of Bioimpedance Spectroscopy of Normal, Ischemic and Hemorrhagic Rabbit Brain Tissue at Frequencies from 10 Hz to 1 MHz. Sensors 2016, 16, 1942. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  16. Garnett, J.C.M., XII. Colours in metal glasses and in metallic films. Philos. Trans. R. Soc. London. Ser. A Contain. Pap. A Math. Phys. Character 1904, 203, 385–420. [Google Scholar] [CrossRef] [Scilit]
  17. Bruggeman, D.A.G. Berechnung verschiedener physikalischer Konstanten von heterogenen Substanzen. I. Dielektrizitätskonstanten und Leitfähigkeiten der Mischkörper aus isotropen Substanzen. Ann. Phys. 1935, 416, 636–664. [Google Scholar] [CrossRef] [Scilit]
  18. Markel, V.A. Introduction to the Maxwell Garnett approximation: Tutorial. J. Opt. Soc. Am. A 2016, 33, 1244–1256. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  19. Gratiy, S.L.; Halnes, G.; Denman, D.; Hawrylycz, M.J.; Koch, C.; Einevoll, G.T.; Anastassiou, C.A. From Maxwell’s equations to the theory of current-source density analysis. Eur. J. Neurosci. 2017, 45, 1013–1023. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  20. Berre, N.; Rognes, M.E.; Massing, A. Cut Finite Element Discretizations of Cell-by-Cell EMI Electrophysiology Models. SIAM J. Sci. Comput. 2024, 46, B527–B553. [Google Scholar] [CrossRef] [Scilit]
  21. Poignard, C. About the transmembrane voltage potential of a biological cell in time-harmonic regime. ESAIM Proc. 2009, 26, 162–179. [Google Scholar] [CrossRef] [Scilit]
  22. Baumgartner, C.; Hasgall, P.A.; Di Gennaro, F.; Neufeld, E.; Lloyd, B.; Gosselin, M.C.; Payne, D.; Klingenböck, A.; Kuster, N. IT’IS Database for Thermal and Electromagnetic Parameters of Biological Tissues, Version 5.0; IT’IS Foundation: Zürich, Switzerland, 2025. [Google Scholar] [CrossRef]
  23. Zolgharni, M.; Ledger, P.D.; Griffiths, H. Forward modeling of magnetic induction tomography: A sensitivity study for detecting haemorrhagic cerebral stroke. Med. Biol. Eng. Comput. 2009, 47, 1301–1313. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Scharfetter, H.; Lackner, H.K.; Rosell, J. Magnetic induction tomography: Hardware for multi-frequency measurements in biological tissues. Physiol. Meas. 2001, 22, 131–146. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.