1. Introduction
Monitoring maternal and fetal health is central to perinatal care, supporting timely clinical intervention and appropriate decisions about the timing of birth to reduce the risk of stillbirth and adverse neonatal outcomes. Fetal–maternal monitoring relies on a range of technologies, with fetal heart rate (FHR) monitoring and ultrasonography among the most used to assess and manage pregnancy-related risks and complications. Yet important gaps remain between the information clinicians require and what current technologies can provide.
Stillbirth and perinatal morbidity remain major global health challenges, with intrapartum hypoxic–ischemic events contributing substantially to these adverse perinatal outcomes. In their 2023 review, Mendis et al. cited estimates of more than 2 million stillbirths worldwide each year, with regional estimates of the proportion occurring during labour ranging from 6% to 49% [1]. These figures show the need for better identification of pregnancies at increased risk, timely recognition of suspected fetal hypoxia, and appropriate clinical interventions to reduce the risk of adverse perinatal outcomes.
While FHR monitoring is widely used in obstetric care, its visual interpretation remains subject to significant observer variability [1,2]. Randomized controlled trials of some computerized intrapartum cardiotocography (CTG) interpretation systems have not demonstrated improved clinical outcomes [2]. Reliable, objective, and clinically relevant interpretation of CTG patterns remains challenging within the dynamic obstetric environment. At the same time, translating these findings into appropriate clinical decisions and interventions that improve perinatal outcomes remains equally challenging.
Large clinical datasets, advances in machine learning, new sensing technologies, and experimental models offer opportunities to address these gaps. Their value depends on whether they can provide reliable information that improves clinical decisions. This Special Issue brings together work from clinical, engineering, and physiological perspectives, addressing antenatal surveillance, labour monitoring, and neonatal care. As we recognize that fetal and neonatal health is a continuum, two contributions extend beyond birth by examining haemodynamic changes in preterm infants and epileptic-spasm detection in infants and young children.
The twelve contributions discussed here comprise seven original research articles and five reviews. We organize them under four themes: methodological foundations; risk stratification; physiology-informed modelling; and emerging sensing technologies and monitoring beyond birth. Table 1 provides an overview [1,2,3,4,5,6,7,8,9,10,11,12].
Table 1.
Overview of the twelve contributions discussed in this editorial, grouped by theme.
The collection addresses selected problems across antenatal, intrapartum, neonatal, and pediatric monitoring, combining foundational reviews with original modelling studies.
2. Foundations: Signal Quality, Evidence, and the Translation Gap
Three reviews set out the methodological basis of computerized fetal monitoring. Campos et al. conducted a PRISMA-ScR scoping review of methods for preprocessing the FHR signal, including 54 studies after database screening and reference checking [4]. They found that detection of poor signal quality typically relies on deviations from neighbouring samples, whereas correction usually relies on interpolation. They also found no consensus on how missing samples, outliers, and artefacts in the data should be defined. The review maps current methods; it does not establish which preprocessing approach is most effective.
Mendis et al. surveyed the full pipeline of computerized CTG analysis, including FHR and uterine-contraction sensing technologies, public and private datasets, preprocessing, and classification algorithms [1]. The quality of the CTG data is recognized as one of the main challenges to achieving the performance needed for clinical implementation. The authors offered recommendations for overcoming the barriers that have kept automated CTG analysis out of routine practice.
Varisco et al. added a narrative review with a systematic approach covering 30 studies on intrapartum acidemia prediction [5]. They report that guideline-based CTG interpretation often yields intermediate-risk classifications, and that evidence on the added value of fetal electrocardiogram ST analysis remains conflicting. They also report that individual FHR features can discriminate acidemic from healthy fetuses, and they identify models that integrate multiple features as a promising direction. Differences in acidaemia definitions and evaluation methods limit direct comparison across studies.
Across these reviews, progress requires advances in classifiers alongside standardized preprocessing; shared benchmarks; large, public, and multicentre datasets; and rigorous validation against meaningful outcomes.
3. Machine Learning for Risk Stratification Across Pregnancy and Labour
Three original articles apply data-driven models at different points in pregnancy and labour. Asfaw et al. analyzed the first 20 min of FHR recordings in a retrospective cohort of 51,449 births at 36 weeks’ gestation or later [3]. They compared one-dimensional convolutional neural network (CNN) and long short-term memory (LSTM) architectures with two-dimensional CNNs applied to spectrogram and scalogram representations. The parallel 1D-CNN–LSTM architecture performed best, and the best model achieved 20% sensitivity at 95% specificity. This result showcases the difficulty of predicting early-labour. It also shows the value of reporting operating points that make the trade-off between sensitivity and false-positive rate explicit.
Davis Jones et al. analyzed 8881 antepartum FHR recordings acquired before 37 weeks [2]. They compared 4867 recordings associated with preterm adverse outcomes with 4014 recordings from pregnancies subsequently delivered at term without the specified complications. A random forest using seven FHR-derived features achieved an area under the curve (AUC) of 0.88 on internal validation (95% confidence interval [CI] 0.86–0.90). The authors also reported a Brier score of 0.14 and favourable decision-curve results. These findings support further investigation of risk stratification within indicated antenatal surveillance. Because the cohort was selected and outcome-enriched, external validation and assessment of clinical impact remain necessary before applicability to screening or resource-limited settings can be established.
Zhoroev et al. investigated labour progression, an important consideration in labour management that, alongside CTG findings, informs decisions about clinical intervention and the timing of birth [6]. Their Gaussian process model jointly predicts cervical dilation and fetal station from previous pelvic examination findings, cumulative contraction count, epidural status, and induction status. It outperformed a mixed-effects model, was evaluated on a geographically separate validation dataset, and provided delivery-specific uncertainty estimates. These properties support potential real-time clinical use, which would need confirmation through prospective evaluation.
Together, these studies show a move towards uncertainty-aware clinical decision support assessed with clinically meaningful and interpretable metrics.
4. Physiology-Informed Modelling and Translational Animal Models
A strength of this collection is its inclusion of animal studies investigating fetal physiology, providing insights that cannot be obtained directly in human labour.
Tolladay et al. trained a convolutional neural network on 2698 umbilical cord occlusions from 57 near-term fetal sheep to estimate minimum fetal blood pressure during FHR decelerations [7]. In sheep, the model achieved a mean absolute error of 6.7 mmHg (R2 = 0.36). The authors then applied it to decelerations from 53,445 human CTG recordings. Human fetal blood pressure was not measured, so this application does not validate the accuracy of blood-pressure estimation in humans. The model could not yet clearly predict severe compromise in humans, but the work outlines a possible route towards non-invasive estimation of fetal hypotension, which may serve as an empirical marker of fetal compromise.
Frasch proposed the concept of a heart rate variability (HRV) code [8]. The review synthesizes experimental evidence, including studies in fetal sheep and neonatal piglets, suggesting that process-specific subsets of HRV measures may carry signatures of the fetal systemic inflammatory response, organ-specific inflammation of the brain and gut, chronic hypoxia, allostatic load, and vagotomy. This framework is a hypothesis supported by experimental evidence, not an established clinical diagnostic code.
Abbasi et al. evaluated CNN-based seizure classifiers using 31,015 annotated electroencephalography (EEG) segments from 40 preterm and near-term fetal sheep after hypoxia–ischemia, including experiments with therapeutic hypothermia [9]. The authors reported an average five-fold cross-validated accuracy of approximately 99.7%. Performance differed according to the developmental groups used for training and testing, and preterm seizures did not contain all the spectral features seen at term. Both findings suggest that maturational differences in seizure morphology matter for model development. The recordings came from dural electrodes, which have a higher signal-to-noise ratio than routine scalp EEG. These preclinical results therefore require validation in neonatal scalp EEG, and high segment-classification accuracy does not establish bedside event-detection performance. The pooled five-fold analysis should not be interpreted as evidence of generalization to unseen animals unless animal-level separation is confirmed.
These studies show that controlled experimental physiology can help guide the development of computerized monitoring features and predictive models intended that may eventually be tested in human clinical settings.
5. Emerging Sensing Modalities and Monitoring Beyond Birth
Fetal–maternal monitoring depends on the quality of the signals it acquires. Giordano et al. conducted a PRISMA-guided scoping review of acquisition hardware for fetal phonocardiography (FPCG), identifying 57 studies that describe 26 research prototypes and eight commercial devices [10]. None of the commercial devices was designed specifically for fetal use. Recent advances involve the use of multi-microphone and multi-sensor designs, but quantitative validation is usually lacking. As FPCG is a passive and non-invasive modality, it may be suitable for long-term and remote monitoring, although the review identifies unresolved obstacles to home use.
Two articles extend automated physiological-signal analysis to neonatal and pediatric applications. Although these contributions go beyond birth, they reflect the continuum between obstetrics and neonatology, with technological advances in each field offering insights that can inform the other. Huang et al. evaluated YOLO-based extraction of five echocardiographic parameters in preterm infants with patent ductus arteriosus, using a single-centre dataset from 33 infants [11]. The best parameter-specific models achieved mean average precision at an intersection-over-union threshold of 0.50 (mAP50) ranging from 81.15% to 99.50%. These are object-detection metrics, not measures of diagnostic accuracy for haemorrhagic complications. The findings support further evaluation of automated echocardiographic measurement.
Feng et al. developed IESS-FusionNet to classify epileptic-spasm and non-spasm windows in synchronized EEG and surface electromyography (EMG) recordings from ten children aged 5 months to 4 years with confirmed infantile epileptic spasms syndrome (IESS) [12]. The dataset comprised 129 recordings. The model combines dual-stream signal encoding with a Receptance Weighted Key Value (RWKV)-based cross-modal fusion module. It achieved a reported mean accuracy of 89.5%, specificity of 90.7%, and sensitivity of 88.3% across five experiments using a subject-level 8:1:1 training, validation, and test split, that is, with a single test patient in each experiment. Their results describe spasm-window classification in a small cohort with confirmed diagnoses, but not syndrome screening in an unselected population. Larger independent cohorts are needed to assess generalisability and clinical readiness.
These contributions explore automated acquisition and analysis beyond conventional FHR monitoring. Clinical implementation will require further evaluation, and their populations, clinical tasks, and evidence requirements remain distinct.
6. Conclusions
The contributions discussed in this editorial examine how quantitative, physiology-informed, and data-driven methods could improve monitoring and help to prevent adverse perinatal and neonatal outcomes. For FHR monitoring, this means moving beyond subjective visual interpretation; beyond FHR, it includes new sensing modalities, experimental models, and automated analysis of neonatal and pediatric signals. The contributions address selected problems across pregnancy, labour, neonatal care, and pediatric monitoring, using clinical datasets, experimental physiology, sensing hardware, and machine learning, while reporting the limits of current performance. Their results also highlight why technical performance, and clinical value must be evaluated separately.
Several priorities recur across the collection: consistent preprocessing and outcome definitions; shared, large benchmark datasets; validation with appropriate participant-level separation; testing in independent populations; and prospective evaluation within clinical workflows. Models that combine physiological signals and clinical risk factors also need an assessment of calibration, uncertainty, interpretability, and the consequences of acting on their predictions.
The next step is to improve classification and to establish when additional information changes a clinical decision, and whether that change benefits patients. Collaboration between engineers, physiologists, clinicians, and, ultimately, patient representatives will be essential to identify which approaches can contribute to fewer preventable perinatal deaths, fewer unnecessary interventions, and better outcomes for mothers and children.
Funding
This research received no external funding.
Acknowledgments
The Guest Editors thank all authors for their valuable contributions, the reviewers for their constructive and timely evaluations, and the editorial staff of Bioengineering for their support in preparing this Special Issue.
Conflicts of Interest
M.G.F. holds an ECG-related patent (WO2018160890A1) and a fetal EEG patent (US9215999B2), and is a co-founder of, and holds equity in, several pregnancy-health start-ups. A.G. is a founder and director of Safer Birth Ltd. The other authors declare no conflicts of interest.
References
- Mendis, L.; Palaniswami, M.; Brownfoot, F.; Keenan, E. Computerised Cardiotocography Analysis for the Automated Detection of Fetal Compromise during Labour: A Review. Bioengineering 2023, 10, 1007. [Google Scholar] [CrossRef] [Scilit]
- Asfaw, D.; Jordanov, I.; Impey, L.; Namburete, A.; Lee, R.; Georgieva, A. Multimodal Deep Learning for Predicting Adverse Birth Outcomes Based on Early Labour Data. Bioengineering 2023, 10, 730. [Google Scholar] [CrossRef] [Scilit]
- Davis Jones, G.; Cooke, W.R.; Vatish, M. Identifying High-Risk Pre-Term Pregnancies Using the Fetal Heart Rate and Machine Learning. Bioengineering 2026, 13, 203. [Google Scholar] [CrossRef] [Scilit]
- Campos, I.; Gonçalves, H.; Bernardes, J.; Castro, L. Fetal Heart Rate Preprocessing Techniques: A Scoping Review. Bioengineering 2024, 11, 368. [Google Scholar] [CrossRef] [Scilit]
- Varisco, G.; Steyde, G.; Peri, E.; Hoogendoorn, I.; Signorini, M.G.; van Laar, J.O.E.H.; Mischi, M.; van der Hout-van der Jagt, M.B. Predicting Intrapartum Acidemia: A Review of Approaches Based on Fetal Heart Rate. Bioengineering 2026, 13, 146. [Google Scholar] [CrossRef] [Scilit]
- Zhoroev, T.; Hamilton, E.F.; Warrick, P.A. Data-Driven Insights into Labor Progression with Gaussian Processes. Bioengineering 2024, 11, 73. [Google Scholar] [CrossRef] [Scilit]
- Tolladay, J.; Lear, C.A.; Bennet, L.; Gunn, A.J.; Georgieva, A. Prediction of Fetal Blood Pressure during Labour with Deep Learning Techniques. Bioengineering 2023, 10, 775. [Google Scholar] [CrossRef] [Scilit]
- Frasch, M.G. Heart Rate Variability Code: Does It Exist and Can We Hack It? Bioengineering 2023, 10, 822. [Google Scholar] [CrossRef] [Scilit]
- Abbasi, H.; Davidson, J.O.; Dhillon, S.K.; Zhou, K.Q.; Wassink, G.; Gunn, A.J.; Bennet, L. Deep Learning for Generalized EEG Seizure Detection after Hypoxia–Ischemia—Preclinical Validation. Bioengineering 2024, 11, 217. [Google Scholar] [CrossRef] [Scilit]
- Giordano, N.; Sbrollini, A.; Morettini, M.; Rosati, S.; Balestra, G.; Gambi, E.; Knaflitz, M.; Burattini, L. Acquisition Devices for Fetal Phonocardiography: A Scoping Review. Bioengineering 2024, 11, 367. [Google Scholar] [CrossRef] [Scilit]
- Huang, L.-C.; Zheng, Z.-W.; Lin, M.-C.; Tsai, Y.-T. Evaluating Hemodynamic Changes in Preterm Infants Using Recent YOLO Models. Bioengineering 2025, 12, 815. [Google Scholar] [CrossRef] [Scilit]
- Feng, J.; Liu, Z.; Shen, L.; Luo, X.; Chen, Y.; Li, L.; Zhang, T. IESS-FusionNet: Physiologically Inspired EEG-EMG Fusion with Linear Recurrent Attention for Infantile Epileptic Spasms Syndrome Detection. Bioengineering 2026, 13, 57. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.