Review Reports
- Patrick Downes 1,*,
- Andy Banks 2 and
- Jack Ingledew-Gale 1
- et al.
Reviewer 1: Anonymous Reviewer 2: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsThe paper describes the planning and execution of environmental monitoring during the NORI mining trial. I found the discussion of instrument performance and sampling difficulties particularly useful. My main concerns are the uncertainty in the penetration-depth estimate, the interpretation of plume observations, and inconsistencies in the operational data. Several references also need attention.
(1) The mean penetration depth of 3.6 cm is estimated from post-mining bathymetry and an interpolated surface representing the original seabed. It is therefore not a direct measurement of the difference between surveyed pre- and post-mining surfaces. This distinction should be clearer in the main text. The 5 cm grid spacing does not establish the vertical accuracy of the estimate. The authors should report the bathymetric uncertainty and examine how the result changes with the smoothing and interpolation settings. Testing the reconstruction on undisturbed areas would help establish the error associated with the method. It is also unclear how representative the approximately 350 m section of PR.1 is of the wider operation. Since redeposition and mechanical displacement can both alter seabed elevation, the measured depression should not be treated as equivalent to the depth of sediment removal without further discussion.
(2) The description of plume detectability is difficult to follow. Lines 595–597 state that the benthic plume was rarely detectable beyond approximately 200 m, yet lines 677–695 report repeated detections by AUVs operating approximately 1–2 km from the collector. Differences in sampling height, timing and instrument response may explain this, but the text needs to make those differences clear. Please give the background turbidity levels and the criteria used to identify a plume, together with the relevant sensor calibration information.
(3) The specific contribution of this manuscript should be distinguished more clearly from previous multi-platform monitoring studies and companion publications arising from the NORI trial. The integrated collection, lifting, and discharge operation provides a valuable setting, but the manuscript should identify which monitoring methods, performance assessments, and findings are newly presented here. References to companion studies are appropriate, but their findings should be clearly separated from results demonstrated in this manuscript.
(4) The conclusions should distinguish monitoring performance, measured environmental pressures, and biological effects. This manuscript mainly demonstrates data acquisition and characterizes selected physical observations; detailed biological, chemical, and acoustic impact assessments are largely addressed elsewhere. Claims concerning the completeness of environmental assessment and applicability to commercial operations should therefore be qualified. The short, intermittent trial and the approximately 11-hour sustained full-capacity run do not establish the consequences of continuous commercial-scale operations.
(5) Please check the air-injection pressure at lines 248–249. The stated value is approximately 20 bar at an injection depth of 2,500 m. The measurement location and pressure reference are needed to interpret this value. In particular, specify whether it is an absolute pressure, a gauge pressure or a pressure difference across a component.
(6) The monitoring coverage during the full-capacity run, PR.1, needs clarification. According to Table 1, the Island Pride monitoring campaign ended on 2 November, before PR.1 took place. Figure S14 also shows that the CTD/NTU records from most FT and FBCT stations ended before this run. Although some instruments remained operational, the coverage available during PR.1 was clearly different from that of the earlier tests. This is difficult to reconcile with the statements at lines 802–812 that reliable turbidity records were obtained throughout the programme and that instrument failures did not materially reduce spatial coverage. Since PR.1 is central to the discussion of monitoring under full-capacity operation, the authors should identify which usable records constrain plume extent, intensity and duration during this run. If observations from lower-capacity tests are used to characterize conditions during PR.1, the basis for doing so should be explained.
I also noted the following editorial points:
Line 1154: correct “Niskin bottes” to “Niskin bottles”.
Line 1160: correct “though leakage or backflow” to “through leakage or backflow”.
Line 1198: correct “dispersion an sedimentation” to “dispersion and sedimentation”.
Line 1337: “The steps … is outlined” should be “The steps … are outlined”.
References [36] and [62] are duplicate entries for the same Iannotta et al. paper. One entry should be removed and the citations renumbered.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsThe prepared study is scientifically significant. The dataset is rich and valuable. However, the most fundamental weakness of the article is the incomplete interpretation of the environmental monitoring results. The study falls between a scientific article and a report. Because the article provides a comprehensive account of field monitoring activities. The ecological interpretation of the findings is incomplete. The scientific results and claims should be further supported by data.
A more rigorous statistical evaluation of the monitoring data, clearer comparisons between control and affected areas or periods, and a stronger ecological interpretation of the observed patterns would significantly contribute to the article. Operational details should be shortened. Some information in the discussion section is repeated in the findings section. Also, concepts such as "first," "world's first," etc., should be supported by comprehensive literature.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThe revision has improved the manuscript. The scope is clearer, and the discussion now gives a more accurate account of the limitations in monitoring coverage during PR.1. The explanation of differences between ROV and AUV plume observations is also helpful. The duplicate reference and the incorrectly specified air-injection pressure have been addressed. However, the uncertainty in the penetration-depth estimate remains unresolved, and several operational quantities need clearer definitions. I recommend further major revision, focusing on the following points.
- The response to the first comment does not yet quantify the uncertainty in the reconstructed seabed surface. A vertical resolution of 1 cm does not establish vertical measurement accuracy. Likewise, an approximately normal distribution of elevation changes, with similar mean and median values, does not rule out a systematic error in the reconstructed reference surface. The reported percentiles describe variation across the disturbed track; they do not establish the uncertainty of the depth estimate.
Appendix B explains why the authors chose interpolation rather than pre/post-survey differencing, but the accuracy of that interpolation still needs to be tested. One practical approach would be to withhold strips of approximately the same width from undisturbed seabed, reconstruct them using the same procedure, and compare the reconstruction with the measured surface. An equivalent validation would also be acceptable. The authors should report the reconstruction error and show how the mean PD changes across a reasonable range of smoothing parameters.
The comparison with the XRF/XRD estimate of “up to 5 cm” does not resolve this issue. A maximum estimate and a mean estimate are different quantities. If this comparison is intended as independent validation, the relevant sampling locations, definitions and uncertainties should be provided.
- The interpretation of net elevation change as separate cutting and mechanical-disturbance contributions remains insufficiently supported.
The clarification that PD represents net elevation change relative to an interpolated unmined surface is appropriate. However, the manuscript still identifies the central depression of 3.0 cm as cut depth and attributes the additional 0.8–1.6 cm beneath the caterpillar tracks to mechanical disturbance. Differences between regional mean elevations cannot, by themselves, isolate these processes. Erosion, compaction, lateral displacement and redeposition may contribute differently across the track. Unless independent evidence supports this separation, the values should be presented as estimated net depressions in the central and tread regions. The attribution of their differences to specific processes should be qualified.
The statement at lines 1466–1467 that a systematic elevation change would not alter the reported PD also needs qualification. A common elevation offset affecting both the track and reference surface could cancel, whereas unequal redeposition in the mined and reference areas would change the estimated depression.
- The time and mass bases of the operational quantities need to be reconciled. For PR.1, the manuscript reports approximately 18–19 kg s−1 maintained continuously for approximately 11 h. On a common mass basis, this would correspond to approximately 713–752 t, whereas Table A1 reports 604 t. Please explain whether these quantities use different time intervals, measurement locations or dry/wet mass definitions, and whether temporary storage within the system affects their correspondence. A related clarification is needed for STR.3.1. Table A1 lists 448 t and an operating time of 3.5 h, while Figure S7 shows a discharge period exceeding 6 h. The operating time may therefore refer to collector activity rather than the full lifting or discharge period. These distinctions should be stated explicitly before rates and cumulative quantities are compared. Figure S7 presents discharge mass spill rate, rather than nodule production rate. The authors should identify the operational records supporting the reported nodule production rates and explain how the time-integrated rates relate to the recovered mass.
- The averaging interval for the reported discharge mass spill rate should be specified.
The caption of Figure S7 states that the dashed lines represent mean non-zero mass spill rates. The main text reports an average of approximately 0.3 kg s−1 during PR.1 without identifying this averaging convention.
Please clarify whether this value applies to the approximately 11 h steady-state production phase, all non-zero discharge intervals, or the complete run including interruptions. The corresponding duration and total discharged mass should also be reported. This distinction matters when the value is used to parameterize plume models, because a mean calculated only during active discharge does not describe the release over the complete operational period.
- Figure S4 is a useful addition, but the detection-threshold calculation is still unclear. The caption refers to “unbiased empirical noise floors”, yet the estimator and its statistical basis are not defined. Please specify how the baseline periods were selected, the number of observations used, the definition of the box-plot whiskers, and the calculation linking these distributions to the thresholds reported at lines 441–450. It should also be clear whether thresholds were determined for each individual sensor or applied across an instrument type. The distinction between baseline offset, background variability and instrumental noise should be maintained. The handling of the drift-affected RBR records should also be stated explicitly, including whether they were used only as supporting evidence for plume detection.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Round 3
Reviewer 1 Report
Comments and Suggestions for AuthorsThe authors have substantially addressed my previous concerns. The reconstruction tests on undisturbed seabed provide useful evidence for the penetration-depth estimate, and the added conveyor-belt records clarify the production rates and corrected run totals. The discharge averaging convention is also now explicit. I recommend minor revision to address the following remaining points.
1. Please clarify the statistical meaning of the reported ±2.1 cm uncertainty. Using per-line means to account for spatially correlated pixels is appropriate, but the exact calculation, including the formula and degrees of freedom, should be stated. Multiplying the standard deviation of reference-line means by a t critical value describes a different quantity from a confidence interval on their overall mean. Please explain how this uncertainty is transferred to the PR.1 estimate and briefly describe the widths, lengths and spacing of the reference strips. “No detectable systematic bias” would also be more accurate than “no systematic bias”.
2. The smoothing sensitivity test reports changes in reconstruction RMSE on undisturbed seabed. This supports the stability of interpolation in those areas, but does not directly establish the sensitivity of the estimated PD where raised track edges are present. Please report the range of PR.1 mean PD obtained under the tested settings, or limit the sensitivity conclusion explicitly to the undisturbed reference areas.
3. Section 2.3.3 states that detection thresholds were determined for individual sensors, but also describes averaging the thresholds of the ten Hyperion sensors across the array. Please clarify whether individual readings were assessed against their own thresholds or against the array average. If the latter was used, explain how differences in sensor offsets were accommodated. The minimum-variance baseline window also represents particularly quiet conditions; its implications for interpreting detections during more variable background periods should be acknowledged.
4. A final language edit is still needed. Examples include “as a function depth” in Figure 21, “station’s” in Figure 26, and “Knowledge … are fundamental” in the Conclusions. Please also replace “concentrations of approximately 15 NTU” with wording that describes turbidity, since NTU is not a unit of mass concentration.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf