Reviewer 1 Report
Comments and Suggestions for AuthorsThis manuscript presents a retrospective, single-center analysis of imaging strategies in 78 patients with biopsy-proven Langerhans cell histiocytosis and proposes a clinically oriented imaging algorithm. The topic is both relevant and practical, and the manuscript is generally clear and well structured. The emphasis on balancing diagnostic yield with radiation exposure and cost is particularly appropriate among pediatric populations.
However, the study primarily describes local practice patterns rather than giving a direct comparison of imaging modalities. This limitation reduces the strength of the conclusions and necessitates clearer framing.
- A main concern is selection bias. PET imaging was preferred in older patients and in those with suspected systemic or pulmonary disease. Consequently, the higher rate of multisystem disease detected in the PET group likely shows a higher pretest probability rather than superior diagnostic performance of PET. The manuscript should avoid language suggesting diagnostic superiority and should explicitly state that the findings reflect clinical decision-making patterns rather than comparative accuracy.
- There are additional issues regarding the statistical approach. Age is reported as a median and interquartile range, suggesting a non-normal distribution, yet an ANOVA was employed. This difference should be clarified, and non-parametric testing should be considered if appropriate. Exact p-values should be reported where feasible, and Table 2 would benefit from inclusion of a p-value comparing disease extent across imaging groups.
- The proposed clinical algorithm is reasonable and intuitive, however, it is derived from retrospective associations and has not been validated. The language needs to be moderated to reflect this limitation. Statements indicating that PET is “required” in specific pediatric scenarios are overly strong given the current evidence.
- There is an inconsistency in the reported study period: the Methods section states 2006–2024, while the Results section states 2001–2024. This difference requires correction.
- The discussion of cost and value for money is thoughtful but remains mostly speculative, as no formal economic analysis was conducted. This section should be shortened or reframed to more accurately reflect its illustrative character.
- More references should be newer.
- Minor issues:
- clarifying whether PET consistently refers to PET/CT
- correcting the spelling of “Declaration of Helsinki,” etc
- simplifying Figure 3 for improved readability
- including confidence intervals for key proportions, particularly for the detection of multisystem disease
- the reference style should be adapted to the publisher's recommendations.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for Authors1) The submission is a single-center retrospective cohort study (n=78) aimed to identify imaging selection predictors. No formal null hypothesis was stated. The study period was inconsistently reported as 2006-2024 and 2001-2024.
2) The primary study result is that an age stratification was identified: median age 34 years (IQR 8-56) for PET, 13 years (IQR 3-37) for bone scan, and 7 years (IQR 2-14) for skeletal survey (p<0.001). Multisystem disease was detected in 23.3% (7/30) of PET patients versus 2.7% (1/37) with skeletal surveys and 0% (0/11) with bone scans. Confidence intervals were not reported despite being calculated per methods.
3) Clinical relevance pertains to practice patterns in Langerhans cell histiocytosis (LCH) imaging being described. A clinical algorithm was developed and proposed without validation. Academic value is limited by selection bias.
4) Consider the following to improve the manuscript:
4.1) Validation of the algorithm using internal bootstrap validation (e.g., rms package in R) with performance metrics reported before clinical implementation.
4.2) Confidence intervals (Wilson score) must be reported for all proportions.
4.3) Whole-body magnetic resonance imaging should be discussed as an emerging radiation-free alternative with similar sensitivity to PET.
4.4) Multivariable logistic regression adjusting for selection bias (age, presenting site) should be performed using Firth's bias-reduced method (logistf package) suitable for small samples, reporting adjusted odds ratios with 95% CIs.
4.5) Clarification of the study period inconsistency (2006 vs 2001) is required.
4.6) TRIPOD guidelines should be followed, including a flow diagram distinguishing model development from validation.
4.7) Sample size justification using events-per-variable (EPV) calculations could be provided to clearly position the manuscript as hypothesis-generating.
4.8) Shapiro-Wilk testing should assess normality assumptions for ANOVA given small subgroups (n=11 bone scan), with non-parametric alternatives (Kruskal-Wallis) if assumptions are violated.
5) The conclusions are not consistent with the evidence provided. Superior PET detection was attributed to diagnostic accuracy rather than confounding by indication. The algorithm's utility was asserted without validation.
6) Regarding illustrative and tabular data:
6.1) Confidence intervals are absent in tables.
6.2) An unvalidated algorithm was presented in Figure 3. Heterogeneous categories were combined in Figure 2. No TRIPOD flow diagram was provided.
7) IRB approval and waiver of consent were reported. Data sharing was limited by HIPAA.
This manuscript uses single-center practice patterns to propose an unvalidated clinical algorithm.
Author Response
Please see the attachment.
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThe authors responded to my comments in detail and explained all of my reservations.
Author Response
We thank the reviewer for providing such helpful recommendations.
Reviewer 2 Report
Comments and Suggestions for AuthorsThe revision was executed with commendable thoroughness. The collegial tone and intellectual honesty demonstrated throughout the response are highly appreciated. While adequate internal validation was performed, the generalizability of the proposed framework remains uncertain.
An ad hoc scoring algorithm as utilized (2/1/0 for fully/partially/unaddressed) with the overall score of 29/30 (97%). Single point is deduced for clinical relevance given current limitations.
Kindly consider a title change to "Age-Stratified Imaging Selection in Langerhans Cell Histiocytosis: Towards a Clinical Decision Framework" to reflect the preliminary nature of the algorithm.
Author Response
Comment 1: "Kindly consider a title change to "Age-Stratified Imaging Selection in Langerhans Cell Histiocytosis: Towards a Clinical Decision Framework" to reflect the preliminary nature of the algorithm."
We thank the reviewer for this recommendation and we agree the change in title best reflects the stage of this study. The title now reflects the change.
Page (1), Lines (2-3): Age-Stratified Imaging Selection in Langerhans Cell Histiocytosis: Towards a Clinical Decision Framework