Review Reports
- Henrik Schröter 1 and
- Udo Kragl 1,2,*
Reviewer 1: Nan Li Reviewer 2: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsThis manuscript presents a valuable experimental investigation into the influence of module hydrodynamics and concentration polarization on the determination of nanofiltration membrane pore size. The comparison between two channel designs is informative, and the experimental work appears technically sound. However, several central interpretations and methodological assumptions require further clarification in order to adequately support the conclusions. A major revision is therefore recommended.
1. In Figure 6b, the calculated intrinsic retention for Cell II is reported to be lower than the corresponding observed retention. This result is physically inconsistent because the solute concentration at the membrane interface cannot be lower than the bulk concentration under steady-state filtration conditions. This issue directly challenges the validity of the applied film-theory correction. The authors are requested to provide a thorough discussion of the possible origins of this discrepancy, including the potential overestimation of the mass transfer coefficient km, limitations of the adopted model, or experimental uncertainty. The implications of this inconsistency for the reliability of the correction procedure should also be clearly addressed.
2. The manuscript states that experimentally determined and theoretically calculated km values are in good agreement, as shown in Table 2, while later suggesting that km is likely overestimated, at least for Cell I. This apparent inconsistency requires clarification. The authors should explain how an overestimation of km is inferred despite the reported agreement and should further discuss the sensitivity of the intrinsic retention correction to uncertainties in km, particularly under the low-Reynolds-number flow conditions relevant to Cell I.
3. The Sherwood correlation given in Eq. 11 is applied to both the straight, wide channel of Cell I and the narrow, meandering channel of Cell II. Additional justification is needed for its use in the latter case, where secondary flows, entrance effects, or developing flow regimes may be present. The authors should discuss the applicability and potential limitations of this correlation for the complex channel geometry of Cell II.
4. The conclusions are drawn based on experiments conducted with a single nanofiltration membrane, TS80, and one neutral solute, glucose. Statements suggesting broader implications for nanofiltration membrane characterization should therefore be moderated. It would strengthen the manuscript to explicitly discuss the potential limitations of generalizing the findings to charged solutes, solutes with different sizes or diffusivities, and membranes with different pore structures or surface properties.
5. In the pore size fitting procedure, several physical parameters are combined into a single fitting factor γ. The robustness of this approach should be briefly discussed. In particular, the authors should comment on the potential correlation between the fitted pore radius rp and γ, and how such correlation may influence the confidence in the reported pore size values.
6. To improve the overall clarity and presentation of the manuscript, several editorial issues should be addressed in a consolidated manner. These include ensuring consistent notation throughout the text, for example using a single symbol for permeate flux and applying rp uniformly for pore radius, correcting typographical errors such as “exlusion” in Section 1.2, “phyton” in the Data Availability Statement, and the duplicated verb “must be be” on Page 9, and improving the resolution and readability of Figures 5 and 7 so that data points, trend lines, and labels are clearly distinguishable. In addition, the claim regarding improved sustainability at lower flow rates should be briefly qualified or supported with a concise justification to place this statement in an appropriate and measured context.
Author Response
Thank your for the careful review. Please see attached pdf file with answers.
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsPlease see the attachment.
Comments for author File:
Comments.pdf
Author Response
Thank your for the careful review. Please see attached pdf file with answers.
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThank you for the careful revision. My main concerns raised in the previous review have been satisfactorily addressed, and the manuscript is now suitable for publication.