Review Reports
- Jin W. Kim * and
- Ho-Sang Kim
Reviewer 1: Anonymous Reviewer 2: Anonymous Reviewer 3: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for Authors
The manuscript asks whether an additional procedural synthetic pretraining stage (ImageNet to synthetic to real) improves few-shot industrial defect classification compared with direct ImageNet to real fine-tuning. The authors present it as an evaluation study rather than a new method.
The main findings are largely null. On the wafer data, the apparent synthetic advantage at k = 2 arises mostly from a decline of the ImageNet arm, concentrated in a class with two test parents, and shrinks under head matching. On NEU and MVTec-FS, synthetic features help frozen readouts but not full fine-tuning. On GC10, a fine-tuning gain appears only at k = 1 (+0.038 macro-F1) and reverses at k = 10. The authors conclude that synthetic pretraining must be evaluated with the intended classifier and adaptation procedure, and propose a reporting checklist (Figure 8).
Major comments
The framing does not match the evidence. The title ("Synthetic Pretraining Gains … Depend on …") and the abstract present conditional gains.
In Table 3, the k = 2 difference (+0.0389) has a crossed range that includes zero.
In Table 4, all MVTec-FS differences are below 0.007 in magnitude, and all their ranges include zero. On GC10, only k = 1 has a range excluding zero, and the sign reverses at k = 10.
2. The reported uncertainty omits test-set sampling variance. The crossed ranges resample training seeds and support manifests on a fixed test set. They do not reflect which candidates happen to be in the test set, and this is the dominant source of variance here.
STAIN has one test parent and carries a weight of 1/8 in macro-F1. Changing that single prediction can move macro-F1 by up to approximately 0.125. This exceeds every effect reported for the wafer data (−0.069, +0.039, +0.108).
The authors' own data confirm this. In the all-parent comparison, removing STAIN reduces the gain from +0.1090 to +0.0135 (Table S12). ERO, with two test parents, accounts for 81.2% of the ImageNet decline (l. 357–358).
The 119 test parents come from only three wafers and are not independent. Table S8 shows the sign of the k = 1 difference reversing on wafer 3.
Please add a bootstrap over test parents, stratified by class, for the wafer endpoint, and over query image groups for the public datasets. Report these intervals alongside the crossed ranges. At minimum, report a leave-one-parent-out sensitivity for classes with fewer than five test parents. Please also report the test support of each class next to every class-level result, and state that F1 for a class with one or two test parents is not interpretable on its own.
3. The support levels are nested and partly identical across manifests. The k = 2 selection contains the k = 1 parent plus one more (Table 1). For small classes, the three manifests are not independent draws: DMP and SLP have a mean Jaccard of 1.000 at k = 2 (Table S1). The "support interaction" therefore compares strongly correlated training sets on the same test set. Moreover, the ImageNet arm loses 0.0695 macro-F1 when one labelled example per class is added (Table 3). This is not plausible as a learning effect. It indicates that noise from rare test classes and from the identity of the added parent dominates the signal. The interpretation of the +0.1078 interaction in Section 3.1 should reflect this explicitly, rather than treating it as the primary finding.
4. The wafer test set is not independent of the generator design. The authors state that test wafers had been observed before generator design. CSCR and POL were excluded because "test observations had informed their generation rules".
Table S2 lists grey-level priors per class (e.g., 104.0 ± 34.5 for CTM) that appear to be estimated from real images. Please state from which wafers these and all other renderer parameters were derived. If test wafers were used, this is direct leakage into the treatment arm and must be stated in the main text.
The same 119-parent test set was reused across more than 300 trained models and numerous sensitivity analyses designed after earlier results. This is adaptive overfitting to the test set. The wafer results should be explicitly labelled as exploratory throughout, including in the abstract.
5. Partitioning and augmentation need clarification. The split itself (wafer-level holdout, parent identity retained by all views) appears sound. Several details are missing or ambiguous. For the public collections, the text says images were grouped "before regions and augmented views were assigned to a partition". Please state whether augmented views were generated only from the support partition, on the fly during training, or generated for the whole pool and then assigned by group.
Please describe how the four development-only splits used for recipe selection were constructed: by wafer, by parent, stratified or random. Please confirm that normalisation statistics and any pre-processing parameters were computed on training data only. Please state when the augmentation ranges (gain, bias, gamma, blur, noise) were fixed relative to any evaluation on test wafers. Test-time augmentation with six views is described for the wafer data. Please state whether test-time augmentation was used for NEU, MVTec-FS and GC10. With a context factor of 2.0, crops of neighbouring candidates may overlap. Please report whether this occurs within the test set.
6. Per-class results and confusion matrices are needed for all tasks. Table 3 does not state its metric. Please specify parent-level eight-class macro-F1 on 119 test parents in the caption, and give the test support per class.
Per-class F1 for both arms of the primary wafer comparison is not reported. Table S6 covers only the ImageNet arm, and Table S22 belongs to a different study (the exposure experiment). Please add a main-text table with per-class F1 for both arms at k = 1 and k = 2, together with test support.
Confusion matrices are provided only for the wafer pipelines (Figure S2), where performance is low. They are absent for NEU, GC10 and MVTec-FS, where performance is high and where the matrices would show which classes drive the differences. Please provide them, at least in the Supplementary Materials: for NEU and GC10 at k = 1 and the largest k for all three arms, and per product for MVTec-FS.
7. NEU is saturated and its high scores need qualification. Under full fine-tuning, macro-F1 exceeds 0.99 from k = 5 onwards (Figure 5a, Table S36). NEU-CLS is widely regarded as an easy benchmark, so a ceiling is plausible. However, three points should be addressed. At the ceiling, the comparison cannot discriminate between methods. Only k = 1 and k = 2 are informative, and the text and conclusions should say this. Content grouping produced 1,799 groups from 1,800 images, so it removed almost no dependence. NEU images are crops from a limited number of steel strips, and specimen and batch identifiers are unavailable. Crops of the same physical strip are therefore likely to appear in both support and query, which inflates scores. NEU has been public since 2013, and possible exposure during foundation-model pretraining is unknown. The near-domain control (macro-F1 = 1.0 for the synthetic arm, Table S39) evaluates the generator on its own distribution. It is trivially expected and should not be presented as evidence that the evaluation can detect a benefit.
Recommendation: Major revision
Author Response
We appreciate your precious comments.
Please see the attachment.
Author Response File:
Author Response.docx
Reviewer 2 Report
Comments and Suggestions for AuthorsThe paper presents how synthetic-data pretraining affects classification performance, including how this effect depends on the performance of ImageNet-based models. The model input may also include images of object defects of types that were not presented during training. The study was conducted on image datasets that contain industrial defects of various classes. The paper also states its limitations, including those for defects without a supplied location and for objects with multiple defects in a single image. Part of the paper is devoted to interpreting the effects of using synthetic data.
The experimental part is described in detail. It covers the image acquisition technology, although the optical parameters are not disclosed because they are proprietary. The paper describes in detail how the data were prepared and partitioned to compare the effectiveness of the machine learning models, as well as the principles of computation and the required evaluation metrics. The paper is accompanied by extensive supplementary materials. Given sufficient time, these materials allow readers to clarify particular details of the experiments and findings leaded. They also enable readers from the educational sector to develop a variety of teaching materials across a broad range of research interests in machine learning and applications.
Nevertheless, the reviewer has the following general comments.
- The paper presents an overall scheme of the study but does not describe the corresponding experimental schemes, that is, the computational algorithms, in detail. Since the paper reports an experimental study, the way this study is constructed should be formalized.
- The structure of the paper deviates somewhat from IMRaD: the Related Work is embedded in the Introduction. A separate section reviewing related studies is recommended (reviewer suggest to form a table with comparative analysis of previous solutions).
- The object of the study can be traced throughout the paper, but it is not formally described. The authors are encouraged to present an information model of the research object with appropriate mathematical or graphic notation. This would make it clearer how the synthetic extension differs from the baseline solution.
- The method presented in the paper is generally understandable after reading the entire text. However, the authors gave priority to a sequential description of the complex experiment. The original method itself, which is based on the specific features of the research object, is not described in a structured way.
- The reviewer could not find any hypotheses in the paper or any description of the procedure for testing them.
To the authors' credit, the experiments they conducted and described step by step led them to an original scheme for drawing conclusions about the effectiveness of synthetic pretraining. Although this scheme is semi-formal, it effectively represents the main scientific contribution of the paper. However, it is presented after the description of the complex experiment rather than in the methodological part. In the reviewer's opinion, a theoretical explanation of how this contribution works is a subject for future, in-depth research. As for the hypotheses, their formulation depends on various conditions that are identified during the experiments. Therefore, whether to make these revisions is left to the authors' discretion.
Specific comment:
- Figure 2. The endpoints of the segments representing the mean values (along the x-axis) do not align with the labels "1 parent" and "2 parents". It is also suggested that the thin lines be coloured so that readers can tell which approach each line belongs to: with or without synthetic data.
Author Response
We appreciate your precious comments.
Please see the attachment.
Author Response File:
Author Response.docx
Reviewer 3 Report
Comments and Suggestions for AuthorsThis manuscript examines whether pretraining on synthetic defects improves industrial defect classification compared with direct ImageNet transfer, using a wafer dataset and three public datasets. However, several issues should be considered.
(1) The training hyperparameters are given, but the generation rules, key parameters and implementation procedure of the synthetic defects are not described clearly. For example, the NEU synthetic source is described in only one sentence ("200 geometries per class"), yet it is reused directly for MVTec-FS and GC10.
(2) As an empirical evaluation study, the paper does not necessarily need to propose a new algorithm. However, it is not yet clear what new and practically useful insights it provides compared with existing transfer-learning studies.
(3) The method is currently described mainly in text, which makes the overall pipeline difficult to follow. The authors are encouraged to formulate the key steps (e.g., the synthetic generation and the transfer/training procedure) with equations and to provide a detailed flowchart and network architecture diagram, so that readers can better understand the method.
(4) The wafer test set contains only 119 defect candidates, some classes have only one or two samples, and the authors acknowledge that "Test images had been observed during development." This weakens the independence of the performance evaluation.
(5) The authors propose an evaluation procedure (Figure 8) rather than a method recommendation. However, the gains from synthetic pretraining are inconsistent across datasets, sample sizes and training strategies, and the procedure is drawn mainly from these limited comparisons. The authors may wish to consider whether its generality is sufficiently supported.
(6) The public-dataset experiments reuse a single generator and a single source-training seed ("one procedural source trained with one seed"), so the conclusions may depend heavily on this one setting.
(7) Although target heads are matched across pretraining routes, the frozen-feature and full fine-tuning evaluations use different classifiers and optimization procedures. Please distinguish readout-specific performance from general claims about feature quality, and clarify whether a controlled comparison using the same classifier architecture with and without backbone updating is available.
(8) The main text states several times that the resampling ranges reflect only variation over the chosen seeds and support selections. However, when the abstract reports the GC10 improvement (0.5569 to 0.5949), this limitation is not mentioned.
(9) The reduction in support interaction after head matching is observed for ConvNeXt-S, whereas ConvNeXt-Tiny shows a slight increase. Please qualify the corresponding statements in the abstract and discussion as referring specifically to the primary ConvNeXt-S comparison.
(10) In Table 4, the shuffled fine-tuning result for MVTec-FS at k=1 (0.6031) is higher than both ImageNet (0.5896) and Synthetic (0.5871), but this is not discussed in the text. Please explain.
Author Response
We appreciate your precious comments.
Please see the attachment.
Author Response File:
Author Response.docx
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThe authors have responded and most first-round comments are resolved. Three issues remain, one of which emerged from the new supplementary material and affects a headline finding.
Remaining major comments
1- Several wafer test parents share an identical whole-wafer input but carry different labels. Table S56 shows that ERO_0006, ERO_0007, SLP_0004 and SLP_0005, all on wafer 3, have an evaluation crop of 3,018 px. Test-wafer images measure 3,018 3,176 px per side, so this window covers the whole wafer. All four windows contain the same 77 other candidate centres. The classifier therefore appears to receive the same, or nearly the same, image for two ERO and two SLP labels. GPIT_0005 and GPIT_0006 on wafer 2 show a similar pattern, with crops of about 2,300 px containing 22–24 other centers.
The consequences are substantial:
The entire ERO test support (n = 2) is one image, and half of the SLP support (2 of 4) is the same image. No classifier can be correct on all four parents.
Figure S2 and Table 5 show the resulting trade-off. At k = 1, ImageNet predicts this image as ERO (ERO F1 0.64, SLP F1 0.00), whereas the synthetic route predicts SLP (ERO F1 0.00, SLP F1 0.24).
The ImageNet decline that accounts for 64.5% of the support interaction, 81.2% of which comes from ERO, therefore largely reflects a changed prediction for a single image with conflicting labels. This is consistent with the sensitivity to wafer 3 in Table S54a.
The original Supplementary Materials (lines 54 to 56) state that these whole-wafer images were not cross-label duplicates because their localised regions differed. The model, however, receives the context window, not the localised region. Duplicate checking was performed at a different level from the model input, which is precisely the type of pseudoreplication the manuscript sets out to address.
I ask the authors to confirm whether these windows are identical after resizing, re-score the wafer endpoint treating identical windows as one observation unit, or excluding whole-wafer candidates, and report the resulting H3 decomposition, state whether whole-wafer crops with conflicting labels also occur in the development set used for training and revise the third finding in the abstract and the conclusions accordingly.
2. The decision rule should use the combined interval, or the abstract should report it. The decision rule requires the crossed range and the test-set interval to exclude zero separately. It was introduced during revision, after the results were known. The combined interval, which resamples both sources of variation together, is the appropriate measure of uncertainty for the reported difference, and the authors themselves describe it as a stricter check.
Under the combined interval, H1 is not supported for any task (Table S53): GC10 k = 1 gives [−0.0128, +0.0951] on manifests 0–2 and [−0.0037, +0.0702] on manifests 0–9, and the mean over source runs gives [−0.0030, +0.0626]. Adopting it would not undermine the paper. The NEU and MVTec-FS frozen-readout gains and H4 on GC10 and NEU remain supported under it, and the conclusion that synthetic pretraining was not consistently beneficial is unchanged.
The abstract currently reports the GC10 gain with its post hoc ten-manifest estimate and test-set interval only (lines 17–18). Please report the pre-specified three-manifest result first and state that the combined interval includes zero. The k = 1 GC10 comparison is also one of eleven unadjusted comparisons (ines 737 to 739), which should be mentioned where the gain is first reported.
3. The dependence of the wafer renderer on the test wafers is only partly resolved.
Background image. All priors, including the re-measured ones, are computed relative to good_removed.bmp, a 3,024x3,024 px defect-free wafer image that also supplies the renderer's background and noise (l. 237–239 Protocol S2). Its size is within the range of the test-wafer images. Please state which wafer it was derived from. If it comes from wafers 1 to 3, even the development-only priors depend on a test image.
Discrepancy between published and measured priors. Table S60a shows that the published priors differ markedly from direct measurements on real patches: PIT 23 versus 79 (all wafers) and 88 (development only); DMP 25 versus 15 and 85. The main text describes the published priors as "measured on real defect patches". Please correct this description and explain the discrepancy.
Weak test for two classes. The development-only priors for dimple and crack rest on a single patch each (table S60a), so the re-measurement experiment is uninformative for those classes.
Other channels. The augmentation ranges were set after the test wafers had been evaluated (lines 226–227), and the class geometry rules were written with test observations available. These should be listed together with the priors as limitations of generator provenance in Section 5.3.
Minor comments
Length and structure. The revised manuscript has grown to 24 pages with eight tables, eight figures and an algorithm, and the supplement to 63 tables, 13 figures, two protocols and a methods note. Much of the added length repeats material rather than adding evidence, and the main findings are harder to extract than they need to be. I suggest the following cuts, which together should shorten the main text substantially without removing any result:
Merge the procedure exhibits. Figure 1, Figure 2a, Algorithm 1 and Figure 3 describe overlapping versions of the same workflow. Keep Algorithm 1 and one overview figure, move Figure 3 to the supplement or fold its checks into Section 5.2.
Compress standard formulations. Equations 4 to 7 state label-smoothed cross-entropy, ridge regression and nearest-prototype classification, which can be given in one sentence with references. The backbone rationale can be reduced.
State recurring caveats once. That crossed ranges describe the recorded grid, that positive-cell counts are not independent replications and that wafer results are exploratory is repeated in most captions and sections. State these once in Section 3.8 and remove the repetitions.
Condense the wafer controls. Section 4.2 (head, schedule, budget, renderer repair, BYOL, OpenCLIP, DINOv2, development selectors, prior re-measurement) can be reduced to a short paragraph pointing to the supplement, since all wafer results are exploratory. The authors may also consider presenting the wafer collection as a secondary case study after the public datasets, which carry the pre-specified hypotheses and are reproducible.
Shorten the Discussion and Conclusions. Section 5.1 restates Section 4.5, Section 5.2 overlaps with Algorithm 1 and Figure 3, and the Conclusions largely repeat the abstract. One paragraph of conclusions would suffice.
Shorten the abstract. A sentence in it is about six lines long, splitting it and dropping the post hoc details would make the abstract easier to read.
Author Response
We appreciate your precious comments!
Please find attached the answers to your comments.
Author Response File:
Author Response.pdf
Reviewer 3 Report
Comments and Suggestions for AuthorsSome figures appear to have been prepared with the assistance of AI tools. I recommend revising these figures to ensure scientific accuracy and improve their clarity and presentation quality.
Author Response
We appreciate your precious comments!
Please find attached the answers to your comments!
Author Response File:
Author Response.pdf
Round 3
Reviewer 1 Report
Comments and Suggestions for AuthorsI thank the authors for their thorough response. All major issues from the previous round have been resolved. I have no further requests and recommend acceptance in its present form.
Reviewer 3 Report
Comments and Suggestions for AuthorsThe authors have revised the mansucript based on the comments. I think it can be accepted.