Comments and Suggestions for AuthorsThis case report describes a clinically relevant and technically interesting application of standing NanoNeedle arthroscopy for removal of osteochondral fragments from the distal interphalangeal joint in a horse. The manuscript is generally well structured and supported by clear intraoperative and radiographic documentation.
However, several minor revisions would improve clarity and scientific balance:
1. The statement regarding novelty should be moderated (e.g., “to the authors’ knowledge”) unless supported by a systematic literature confirmation.
2. Justification for performing standing arthroscopy instead of general anesthesia should be briefly clarified.
3. Sedation parameters should include the detomidine continuous rate infusion dosage.
4. Postoperative medical management should be described in greater detail, including whether systemic anti-inflammatory drugs and antibiotics were continued after surgery, as well as the number of regional limb perfusions performed with amikacin.
5. The Discussion would benefit from inclusion of procedural limitations and risks associated with standing arthroscopy.
6. Conclusions should be slightly tempered given that this report represents a single clinical case.
7. Minor language and typographical errors should be corrected (e.g., duplicated wording, spelling inconsistencies).
Overall, the manuscript represents a valuable contribution and is suitable for publication following minor revision.
Author Response
Comment 1: The statement regarding novelty should be moderated (e.g., “to the authors’ knowledge”) unless supported by a systematic literature confirmation.
Response: Thank you for your valuable comments. We believe we have improved the manuscript significantly with your help.
This has been revised.
Comment 2: Justification for performing standing arthroscopy instead of general anesthesia should be briefly clarified.
Response: A statement has been added to the Introduction to justify standing arthroscopy. “Standing arthroscopy offers several potential advantages. It avoids the risks associated with general anesthesia, including the systemic effects of anesthetic drugs, respiratory complications related to intubation, and the recovery period following anesthesia. Additionally, weight-bearing can increase joint space in certain joints, providing a more anatomically accurate view of the region. In many cases, standing arthroscopy may also be a more cost-effective option for the client.” (Line 43-48)
Comment 3: Sedation parameters should include the detomidine continuous rate infusion dosage.
Response: This information has been added. (Line 63-67)
Comment 4: Postoperative medical management should be described in greater detail, including whether systemic anti-inflammatory drugs and antibiotics were continued after surgery, as well as the number of regional limb perfusions performed with amikacin.
Response: This information has been added. Doxycycline (10mg/kg) was administered twice daily for 7 days post-surgery. In addition, 1 gram phenylbutazone was administered Q12 hours for 3 days then Q24 hours for 3 days. Only a single regional limb perfusion was performed. (Line 99-102)
Comment 5: The Discussion would benefit from inclusion of procedural limitations and risks associated with standing arthroscopy.
Response: Agreed. We have added this portion of the Discussion. “Standing arthroscopy has several important limitations that warrant consideration. Not all joints are readily accessibly in the standing horse, and the ability to manipulate the limb during the procedure is inherently restricted. In addition, even with appropriate restraint, patient movement may occur, resulting in a less stable and less consistent surgical field. Consequently, standing arthroscopy may be considered more technically demanding than procedures performed under general anesthesia. Given these constraints, standing arthroscopy is generally limited to diagnostic applications and relatively minor surgical interventions, such as debridement or fragment removal. Successful execution of standing arthroscopy depends on the use of well-designed and executed sedation protocols that provide sufficient analgesia to minimize patient movement and ensure the safety of both the patient and surgical personnel.” (Line 186-197)
Comment 6: Conclusions should be slightly tempered given that this report represents a single clinical case.
Response: Agreed. We have inserted language to temper our conclusions. We have also included limitations of standing arthroscopy. (Lines 140, 151, 168)
Comment 7: Minor language and typographical errors should be corrected (e.g., duplicated wording, spelling inconsistencies).
Response: Thank you, we have read the manuscript for minor language errors and corrected them where found.
Reviewer 2 Report
Comments and Suggestions for AuthorsDear Authors
Below are our comments and suggestions regarding the manuscript entitled “Standing Arthroscopy of the Distal Interphalangeal Joint for Removal of Osteochondral Fragments of Distal P2 and the Extensor Process in a Horse” submitted to Animals for potential publication, under manuscript ID animals-4179653.
The manuscript maintains a high standard of writing throughout. The results are clear and effectively presented. The discussion is equally well handled, with conclusions that match the authors' objectives . Our only suggestion is that the authors could additionally reference needle arthroscopy procedures performed in cadaveric studies involving horses.
Also, a repeated phrase (A 7 A 7-) appears in the first line (line 48) of the Case Summary section.
Author Response
Comment 1: Our only suggestion is that the authors could additionally reference needle arthroscopy procedures performed in cadaveric studies involving horses.
Response: Thank you, we have included additional references. (Lines 42 - 43)
Comment 2: Also, a repeated phrase (A 7 A 7-) appears in the first line (line 48) of the Case Summary section.
Response: This has been corrected. (Lines 54)
Reviewer 3 Report
Comments and Suggestions for AuthorsDear authors
In summary, this case report describes the first reported use of standing NanoNeedle arthroscopy (2.2 mm scope, 3.2 mm cannula) for therapeutic debridement of dorsal osteochondral fragments from the distal P2 and extensor process of P3 in the right fore distal interphalangeal (DIP) joint of a 7-year-old Quarter Horse-TB cross gelding presenting with grade 3/5 lameness. The main contribution is demonstrating the technical feasibility, improved maneuverability, and excellent short- to medium-term outcome (soundness and return to competition at 5 months, confirmed at 1 year with radiographic remodeling) of this minimally invasive approach under sedation versus traditional general anesthesia. Strengths include detailed procedural description with intraoperative images/radiographs, clear highlighting of ergonomic advantages, and a logical extension of prior standing needle arthroscopy techniques from fetlocks to the anatomically challenging DIP joint.
I have few comments:
-The report comprehensively covers history, diagnostics, procedural details, immediate post-op course, and 1-year follow-up with objective measures (lameness grade, radiographs, performance return), providing a complete clinical narrative.
-Highly relevant to equine surgeons, particularly for field or high-risk anesthetic cases, as DIP extensor process fragments are a recognized cause of chronic lameness with good prognosis after conventional arthroscopy.
-Follow-up timeline is thorough, with consistent lameness grading and radiographic progression to remodeling.
-Lines 1–4: Title is precise and highlights novelty (standing arthroscopy, specific joint/fragments); consider adding "NanoNeedle" to emphasize equipment for searchability.
-Line 47: Minor repetition "A 7 A 7-year-old" correct to "A 7-year-old."
-Lines 57–62: specify detomidine CRI details (e.g., loading dose, rate) as sedation maintenance is critical for standing procedures.
-Lines 88–90: regional perfusion (1g) are standard; quantify perfusion technique (e.g., cephalic/MTP vein, tourniquet time)
Kind regards
Author Response
Comment 1: Lines 1–4: Title is precise and highlights novelty (standing arthroscopy, specific joint/fragments); consider adding "NanoNeedle" to emphasize equipment for searchability.
Response: NanoNeedle has been added to the title. Thank you for this suggestion.
Comment 2: Line 47: Minor repetition "A 7 A 7-year-old" correct to "A 7-year-old."
Response: This has been corrected. (Line 54)
Comment: 3: Lines 57–62: specify detomidine CRI details (e.g., loading dose, rate) as sedation maintenance is critical for standing procedures.
Response: This information has been added. Premed was 25 mg acepromazine, 5mg detomidine, 59mg morphine. Range of detomidine CRI was 0.025 – 0.2 mcg/kg/min (average 0.05 mcg/kg/min). (Lines 64-67)
Comment 4: Lines 88–90: regional perfusion (1g) are standard; quantify perfusion technique (e.g., cephalic/MTP vein, tourniquet time)
Response: This information has been added. Only a single limb perfusion was performed, tourniquet was maintained for 20 min, and the cephalic vein was used. (Line 97-98)