When Does Multimodal Fusion Help? Cross-Domain Transfer, Joint Fusion, and Late Fusion of SLO and OCT for Glaucoma Detection Under an Analysis-Locked Evaluation

,
and
1
Department of AI Software Convergence, Konyang University, Daejeon 35365, Republic of Korea
2
Korea Research Institute of Bioscience and Biotechnology, Daejeon 34141, Republic of Korea
3
Department of Biotechnology, University of Science & Technology (UST), Daejeon 34113, Republic of Korea
4
Department of Artificial Intelligence, Konyang University, Daejeon 35365, Republic of Korea
Diagnostics2026, 16(23), 3936;https://doi.org/10.3390/diagnostics16233936 
(registering DOI)
This article belongs to the Special Issue Deep Learning Techniques for Imaging-Based Diagnosis

Abstract

Background/Objectives: Multimodal deep learning for glaucoma detection often combines fundus imaging with optical coherence tomography (OCT), yet it is unclear when fusion adds information beyond OCT alone and how such models behave under domain shift. We compared joint and late fusion of scanning laser ophthalmoscopy (SLO) and OCT and their cross-domain transfer. Methods: Models trained on GAMMA (color fundus photographs and macular OCT; 99 cases) were applied without retraining to the Harvard-FairVision glaucoma test split (3000 patients; SLO and OCT). Unimodal and multimodal models were then trained on FairVision (6000 training and 1000 validation patients). Four candidates (OCT-only, concatenation and cross-attention fusion, and late fusion with a cross-fitted SLO weight of 0.15) were locked with their calibration and thresholds and evaluated once on the same test split. Results: Cross-domain transfer yielded areas under the receiver operating characteristic curve (AUROCs) of 0.635–0.653. In-domain OCT-only reached a test AUROC of 0.876. Neither jointly trained cross-attention fusion (ΔAUROC −0.0045; 95% confidence interval (CI) −0.0110 to 0.0021) nor concatenation fusion (+0.0009; 95% CI −0.0056 to 0.0074) improved on OCT-only. Late fusion yielded a small ranking improvement (+0.0059; 95% CI 0.0033 to 0.0087; Holm-adjusted p = 0.0012), but a sensitivity gain at matched specificity was not established. Post hoc analyses identified lower AUROC among Black patients and a higher false-positive rate among normal eyes. Conclusions: OCT carried most of the diagnostic information. Standard joint fusion did not add value. Low-weight late fusion improved ranking slightly on a previously accessed test split; this requires independent confirmation and does not establish clinical benefit. Fusion claims require strong unimodal and late-fusion baselines and external validation.

1. Introduction

Glaucoma is a leading cause of irreversible blindness, and a large fraction of cases remain undiagnosed [1,2]. Deep learning applied to fundus photographs and optical coherence tomography (OCT) has shown promise for automated screening [3]. Because the two modalities capture complementary aspects of optic nerve damage, multimodal fusion of fundus imaging and OCT has become a common design choice, and public benchmarks such as GAMMA were created specifically to encourage it [4]. For human readers, adding OCT to fundus photographs raised glaucoma screening sensitivity from 55.4% to 80.0% at a similar specificity [5].
Deep learning models for glaucoma have been developed for each of these modalities [6]. Models based on color fundus photographs achieved high discrimination in large datasets, although performance varied across external datasets that differed in population and camera [7]. Three-dimensional networks applied to spectral-domain OCT volumes detected glaucomatous optic neuropathy with AUROCs of about 0.89 in independent external datasets [8], indicating that OCT alone already carries a strong diagnostic signal.
Multimodal approaches combine structural imaging with functional or clinical information. A network fusing visual field pattern deviation plots with circular peripapillary OCT scans outperformed networks using either input alone [9], and a model combining macular OCT, color fundus photographs and clinical data reached an AUROC of 0.97 in the UK Biobank [10]. Multimodal networks have also been used to predict visual-field results from optic disc photographs and OCT [11]. In such studies, the benefit of fusion is usually measured against unimodal networks trained within the same development data [9].
Two questions are less well answered. First, how much does fusion add beyond OCT alone when the OCT model is strong? Joint training of multimodal networks can underuse a weaker modality, so that the fused model performs no better than its best unimodal branch [12,13]. On Harvard-FairVision, a standard jointly trained SLO–OCT ResNet did not exceed a unimodal OCT ResNet (area under the receiver operating characteristic curve (AUROC) 0.826 versus 0.833), whereas modality-balancing methods (0.839–0.845) and the method proposed in that work (0.861) exceeded both [14]. Second, how do such models behave under domain shift? Medical imaging models frequently lose performance when applied to data from other institutions, devices or imaging modalities [7,15], and multimodal models may be particularly exposed because each branch can shift independently.
Harvard-FairVision provides a large glaucoma cohort with paired scanning laser ophthalmoscopy (SLO) fundus images and three-dimensional OCT, one sample per patient, official splits and demographic attributes [16]. It therefore allows multimodal fusion, domain transfer and subgroup performance to be studied on the same data. Previous work on this cohort and related Harvard datasets has focused mainly on fairness-aware training and has documented differences in glaucoma detection performance between racial groups [14,16,17,18].
In this study we asked when multimodal fusion helps in glaucoma detection. We first applied models trained on GAMMA to FairVision without retraining and analyzed why they failed. We then trained unimodal and multimodal models on FairVision, fixed a small set of candidates together with their calibration and thresholds before accessing the test labels for these models, and evaluated them once on the official test split. Finally, we examined performance across demographic subgroups and decomposed the largest disparity. Relative to previous comparisons on this cohort [14], we add paired confidence intervals on the same test samples, a protocol that fixed calibration and operating thresholds before testing, a separately trained late-fusion baseline and a cross-domain analysis. Our contribution is a comparative and methodological one rather than a new architecture: we report a negative cross-domain result, a pre-specified comparison of joint and late fusion, and a subgroup error analysis, each with explicit statements of what the design can and cannot support.

2. Materials and Methods

2.1. Study Design

This was a retrospective study of two publicly available, de-identified datasets. The study had three parts (Table 1). In E04, models developed on GAMMA were applied without retraining or recalibration to the FairVision test split. In E05, unimodal and multimodal models were trained on the FairVision training split and compared on the validation split; four candidates were then fixed and evaluated once on the FairVision test split. Because the same test split had already been analyzed in E04, the E05 test evaluation is an analysis-locked evaluation on a previously accessed split, not an independent external confirmation. Subgroup analyses were post hoc.
Table 1. Datasets and their roles.

2.2. Datasets

GAMMA contains paired color fundus photographs and OCT volumes graded as normal, early glaucoma or progressive glaucoma [4]. Glaucoma grades were assigned from the visual-field MD (early, MD better than −6 dB; progressive, −6 dB or worse), and non-glaucoma eyes were drawn from a myopia cohort [4]. OCT volumes were acquired with a Topcon DRI OCT Triton, are macula-centered and contain 256 B-scans over a 3 × 3 mm field. All cases came from the GAMMA training partition, which is released with labels. After one case flagged as a potential duplicate was removed, 99 cases were used. Case identifiers are not verified person identifiers, so patient-level independence within GAMMA could not be confirmed.
Harvard-FairVision glaucoma contains 10,000 subjects, with one SLO fundus image and one OCT volume per subject and self-reported age, gender, race, ethnicity, preferred language and marital status [16]. Labels are based on visual function: normal eyes have a visual field (VF) mean deviation (MD) of −1 dB or better with a normal glaucoma hemifield test and pattern standard deviation, and glaucomatous eyes have MD worse than −3 dB with abnormal results on both [16]. Eyes with intermediate findings are therefore absent. We used the official split and included all of its cases; no cases were excluded. Images were acquired, de-identified and labeled by the dataset providers, and acquisition settings are described in the dataset publications [4,16]. The authors performed no additional annotation, and inter- or intra-rater variability of the labels is not reported by the providers. No images, labels or demographic attributes required for the analyses were missing. The anatomical region covered by the OCT cubes is not stated in the dataset paper; related work from the same group derived optic disc and cup boundaries from these OCT scans [19], which suggests optic-nerve-head-centered acquisitions. The dataset is distributed under CC BY-NC-ND 4.0 for non-commercial research.

2.3. Image Preprocessing

For FairVision, the 200 × 200 grayscale SLO image was replicated to three channels. Eight B-scans were selected at uniformly spaced positions out of 200. Eight slices were used to keep full fine-tuning of a 2D encoder over all slices feasible on a single 24 GB GPU and to match the input of the GAMMA source models; the possible effect of this choice is discussed in Section 4.6. The B-scan index axis (axis 0) and depth axis (axis 1) of the OCT array were identified on six training volumes from layer-band structure and slow-axis discontinuity. All images were resized to 224 × 224 with bilinear interpolation, without cropping, and normalized with the ImageNet mean and standard deviation. GAMMA source models used the color fundus image and eight uniformly spaced B-scans out of 256 with the same resizing and normalization.

2.4. Models and Training

All models used a torchvision ResNet18 pretrained on ImageNet with the final fully connected layer removed (512-dimensional features) [20]. OCT features from the eight B-scans were pooled with attention-based multiple-instance pooling that also received the normalized slice position [21]. Concatenation fusion projected OCT and fundus features to 128 dimensions each and combined them in a 256-to-128 layer. Cross-attention fusion used the projected fundus feature as the query over position-encoded OCT tokens (four heads, 128 dimensions). Training conditions differed between E04 and E05 (Table 2), so differences between their results cannot be attributed to the training data alone.
Table 2. Training conditions.
E05 models were trained with AdamW (learning rate 1 × 10−4 for encoders and 1 × 10−3 for heads, weight decay 1 × 10−4), a cosine schedule with one warm-up epoch, batch size 32, up to 20 epochs and early stopping with a patience of five epochs on validation AUROC. Augmentation consisted of a horizontal flip applied jointly to SLO and OCT and independent brightness and contrast perturbations of up to ±10%. Training used bfloat16 mixed precision on a single NVIDIA RTX 3090 (24 GB; NVIDIA Corporation, Santa Clara, CA, USA). A variant of each fusion model initialized from the trained unimodal encoders was also evaluated on validation. To separate the contribution of source-domain training from that of target-domain training, the OCT-only, concatenation and cross-attention models were additionally trained on FairVision from GAMMA-trained weights under the same E05 protocol. For each seed, the fold-1 GAMMA checkpoint with the same seed was used and the three-class classifier was replaced by a new two-class layer. The frozen-encoder OCT-only source model evaluated in E04 (Table 2) was not used for initialization, because its encoder was identical to the ImageNet encoder. Instead, the OCT-only model was initialized from the OCT branch (encoder, attention pooling and projection layer) of the GAMMA concatenation model, and the two fusion models from the corresponding GAMMA fusion models (both encoders and all fusion layers except the classifier). Because these GAMMA fusion models had trained only layer 4 of the OCT encoder, layers 1–3 of all transferred OCT encoders were identical to ImageNet weights; layer 4 differed by a relative Frobenius norm of 0.9–1.7%, with 98% of its parameters changed. The transferred fundus encoders had been frozen and were identical to ImageNet weights. BatchNorm running statistics of all source encoders had been fixed at ImageNet values and were identical at transfer, whereas the BatchNorm scale and shift parameters of OCT layer 4 had been trained. Table S4 lists these components for each architecture. These models were compared on validation only.
As a post hoc control for modality imbalance, added during revision, concatenation fusion was retrained with on-the-fly gradient modulation [13] under otherwise identical conditions (ImageNet initialization, three seeds, validation only). At each step, the contribution of each modality was scored as the mean probability assigned to the true class when the projected feature of the other modality was set to zero. When the ratio ρ of the OCT score to the SLO score exceeded 1, the step size of the OCT encoder was multiplied by 1 − tanh(α(ρ − 1)), and symmetrically for the SLO encoder, with α = 0.5 fixed in advance. This is a variant of the original rule, 1 − tanh(αρ) [13], chosen so that no modulation is applied at balance (ρ = 1). The scaling was applied to the step size rather than to the gradient because AdamW normalizes gradient magnitude, and the Gaussian noise enhancement of the original method was not used. This model was not evaluated on the test split, because it was not part of the locked protocol.

2.5. Late Fusion

Late fusion combined the ensemble probabilities of the separately trained OCT-only and SLO-only models on the logit scale:
zlate = (1 − w) logit(pOCT) + w logit(pSLO)
The SLO weight w was chosen by cross-fitting within the validation split: for each of 20 random stratified two-fold partitions, w was selected on one half from a grid of 0 to 0.5 in steps of 0.05 and applied to the other half. The median selected weight, w = 0.15, was fixed for testing. Within each partition, w was the grid value giving the highest AUROC of the fused score on the selection half, with ties resolved in favor of the smaller weight. Before Equation (1) was applied, probabilities were clipped to [10−6, 1 − 10−6], and the fused logit was the input to Platt calibration. To separate the effect of the weight from that of the score scale, probability averaging and logit averaging were compared at w = 0, 0.15 and 0.50 on the same held-out halves.

2.6. Analysis Lock and Test Evaluation

Before the E05 test evaluation, the following were written to a locked protocol file: the four candidates (OCT-only, cross-attention fusion and concatenation fusion with ImageNet initialization, and late fusion with w = 0.15), per-candidate Platt calibration fitted on validation [22], two operating thresholds (0.5 after calibration and the validation threshold giving 85% specificity), the primary and secondary comparisons, the bootstrap procedure, and SHA-256 hashes of all twelve checkpoints and of the evaluation script. The evaluation script refused to run if any hash changed and allowed a single evaluation. The primary comparison was the AUROC difference between cross-attention fusion and OCT-only; secondary comparisons were concatenation fusion and late fusion versus OCT-only. The protocol file was created on 28 October 2026; test predictions were generated the same day and the single evaluation was run on 29 October 2026 (file timestamps). The code, protocol and hashes were first released publicly later on 29 October 2026 (GitHub and Zenodo, v1.0.0); the lock was therefore not independently time-stamped before the evaluation. Subgroup analyses used the validation-derived 85%-specificity threshold.

2.7. Statistical Analysis

We report AUROC, area under the precision–recall curve (AUPRC), Brier score, expected calibration error (ECE, 10 equal-width bins), and sensitivity and specificity at the locked thresholds. Confidence intervals were obtained from 5000 bootstrap resamples stratified by class; the same resamples were used for all models, giving paired differences. Two-sided bootstrap p-values were computed from the proportion of resamples on either side of zero. Multiplicity adjustment (Bonferroni and Holm [23]) was applied post hoc to the three pre-specified AUROC comparisons. We also report the McClish-standardized partial AUROC for false-positive rates up to 0.2 [24] and, descriptively, sensitivity at a test-matched specificity of 0.85 with thresholds re-estimated within each resample. In FairVision each subject contributes one eye, so the resampling unit is the patient. No formal sample-size calculation was performed; all cases of the official splits were used, which gave 95% confidence interval half-widths of about 0.003 to 0.007 for paired AUROC differences on the test split. To express the trade-off at the validation-derived thresholds, differences in sensitivity and specificity between late fusion and OCT-only were converted to additional detections and additional false-positive referrals per 1000 people at prevalences of 3.5%, representative of population screening [1]; 10%, as a plausible value for a referral or high-risk setting; and 48.9% (the test prevalence). For the comparison at matched specificity, the difference in sensitivity and its confidence limits were multiplied by the number of people with glaucoma per 1000.

2.8. Subgroup Analyses

Post hoc subgroup analyses used the locked predictions, calibration and thresholds. AUROC with 2000-resample stratified bootstrap intervals was computed for subgroups with at least 30 cases and at least 10 cases per class. We summarized disparities with the worst-subgroup AUROC, the maximum AUROC gap and the equity-scaled AUROC (ES-AUC) [17]. Demographic parity difference was not used because subgroup prevalence differed (0.37 to 0.65). To decompose the racial disparity, we computed age-standardized AUROC as the weighted mean of stratum-specific AUROCs over four age strata (<50, 50–59, 60–69 and ≥70 years), with weights given by the age distribution of the full test split and renormalized over strata that met the minimum-size criteria (all four strata met them in each racial group; smallest stratum, n = 45); sensitivity by VF severity among glaucomatous eyes (MD −6 to −3, −12 to −6 and below −12 dB, following [25] within the dataset’s label definition); and the false-positive rate, age and MD of normal eyes at the validation-derived 85%-specificity threshold. The difference in false-positive rates between groups is reported with event counts and a Newcombe hybrid-score 95% confidence interval.

2.9. Software

Analyses used Python 3.11.17, PyTorch 2.14.1 with CUDA 12.6, torchvision 0.29.1, NumPy 2.4.6, pandas 3.1.0 and scikit-learn 1.9.1.

3. Results

3.1. Cross-Domain Transfer (E04)

Models developed on GAMMA discriminated poorly on the FairVision test split and almost never predicted glaucoma at a threshold of 0.5 (Table 3). Cross-attention fusion had a lower AUROC than concatenation fusion (difference −0.0183, 95% CI −0.0258 to −0.0109). Neither fusion model differed significantly from the OCT-only model (concatenation +0.0083, 95% CI −0.0061 to 0.0231; cross-attention −0.0100, 95% CI −0.0259 to 0.0057).
Table 3. Cross-domain transfer of GAMMA-developed models to the FairVision test split (n = 3000).
Predicted probabilities collapsed toward the normal class. The mean predicted probability of glaucoma was 0.093, 0.134 and 0.174 for the three models, against a prevalence of 0.489; the mean three-class probabilities of the concatenation model were 0.907 (normal), 0.066 (early) and 0.027 (progressive). Ranking information was partly retained, with higher mean scores in glaucomatous than in normal eyes (0.111 versus 0.077 for concatenation). All Brier scores exceeded the 0.250 obtained by a constant prediction at the test prevalence, a post hoc reference value rather than a deployable baseline. In the GAMMA development data, the same collapsed binary score, with probabilities averaged over the three seeds before the AUROC was computed, reached out-of-fold AUROCs of 0.950 (concatenation), 0.943 (cross-attention) and 0.900 (OCT-only), with sensitivity at 0.5 of 0.86–0.90 and specificity of 0.78–0.88; with 99 cases, these estimates are imprecise. Two separate failures were therefore present on FairVision: a loss of ranking performance, from 0.90–0.95 to 0.635–0.653, and a near-complete failure of the original 0.5 operating threshold.

3.2. Sources of Domain Shift

Preprocessing was identical between development and transfer: training and inference used the same resizing without cropping and the same normalization, and input statistics computed through both pipelines matched exactly. B-scans were taken at the same relative positions. The datasets nevertheless differed in input modality, geometry and intensity (Table 4). Because encoder BatchNorm statistics had been fixed at ImageNet values during development, test-time BatchNorm re-estimation was not evaluated.
Table 4. Input differences between GAMMA and FairVision.

3.3. In-Domain Unimodal Baselines (E05)

Trained on FairVision, the OCT-only model reached a validation AUROC of 0.851 ± 0.001 (mean ± SD over three seeds) and the SLO-only model 0.766 ± 0.003 (Table 5). Validation AUROC peaked early (epochs 4–5 for OCT and 2–9 for SLO). Mean predicted probabilities of individual seeds ranged from 0.36 to 0.66, so balanced accuracy at 0.5 varied between seeds. These values come from a different split, training data and training configuration than those in E04 (Table 2) and should not be read as the effect of domain adaptation.
Table 5. Validation performance of E05 models.

3.4. Fusion and Source Initialization on Validation (Exploratory)

No multimodal candidate was established as superior to OCT-only on validation. Cross-attention fusion with ImageNet initialization was 0.007 higher than OCT-only (95% CI −0.005 to 0.019), but this comparison used the same split as model selection. Cross-attention fusion initialized from unimodal encoders was 0.023 lower (95% CI −0.041 to −0.006); optimization effects such as learning-rate sensitivity could not be excluded.
OCT-only and SLO-only predictions were moderately correlated (Spearman 0.67; 0.42 within normal and 0.63 within glaucomatous eyes). Equal-weight averaging of probabilities lowered AUROC relative to OCT-only (−0.014, 95% CI −0.027 to −0.000). Because this comparison changed both the weight and the score scale, probability and logit averaging were compared on the same held-out halves (Table S5). At w = 0.15, the mean held-out AUROC difference versus OCT-only was +0.0016 for probability and +0.0028 for logit averaging; at w = 0.50, it was −0.0135 and −0.0115, respectively. The loss at equal weighting was therefore attributable mainly to the weight, not to the score scale. Cross-fitted weight selection chose SLO weights of 0.05 to 0.25 (median 0.15), with a mean held-out AUROC difference of +0.002 (range −0.001 to 0.003; positive in 18 of 20 repetitions). The repetitions reuse the same 1000 cases and are not independent tests.
Initializing from GAMMA-trained weights did not change validation AUROC relative to ImageNet initialization for any architecture (three-seed ensembles): OCT-only 0.8627 versus 0.8622 (difference +0.0005, 95% CI −0.0072 to 0.0081), concatenation 0.8588 versus 0.8581 (+0.0007, 95% CI −0.0090 to 0.0108) and cross-attention 0.8651 versus 0.8694 (−0.0043, 95% CI −0.0133 to 0.0049). Training curves and best epochs were similar under both initializations. In all three comparisons the GAMMA-initialized OCT encoder differed from the ImageNet encoder in layer 4 (Table S4).
To examine modality imbalance directly, the SLO input of the trained ImageNet-initialized fusion models was altered on validation (Table S6). Replacing it with a blank image changed AUROC by −0.010 (95% CI −0.019 to −0.001) for concatenation and by −0.001 (95% CI −0.012 to 0.010) for cross-attention fusion. Replacing it with the SLO image of another patient changed AUROC by −0.023 (95% CI −0.036 to −0.011) and −0.024 (95% CI −0.040 to −0.009), respectively. With a blank SLO image, concatenation fusion was below OCT-only (−0.014; 95% CI −0.026 to −0.004).
With gradient modulation, the OCT score exceeded the SLO score in 99–100% of training steps at the selected epoch (median ρ 1.23–1.27), and the OCT encoder step size was reduced by 12–13% on average. The three-seed ensemble reached a validation AUROC of 0.8625, compared with 0.8581 for standard concatenation fusion (difference +0.0045; 95% CI −0.0036 to 0.0128) and 0.8622 for OCT-only (+0.0003; 95% CI −0.0115 to 0.0125) (Table S7).

3.5. Analysis-Locked Test Evaluation (E05)

The primary comparison did not show an advantage for cross-attention fusion over OCT-only (ΔAUROC −0.0045, 95% CI −0.0110 to 0.0021; Table 6, Figure 1). Its validation advantage did not reproduce on test. Concatenation fusion did not differ from OCT-only (+0.0009, 95% CI −0.0056 to 0.0074). Late fusion yielded a small improvement (+0.0059, 95% CI 0.0033 to 0.0087).
Table 6. Analysis-locked evaluation on the FairVision test split (n = 3000, prevalence 0.489).
Figure 1. AUROC differences of fusion models versus OCT-only on the validation (open circles, exploratory, 2000 bootstrap resamples) and test splits (filled circles, analysis-locked, 5000 paired stratified bootstrap resamples). Error bars are 95% confidence intervals. Late fusion has no validation interval because its weight was cross-fitted on validation. AUROC, area under the receiver operating characteristic curve.
Calibration and thresholds fixed on validation transferred to test, with ECE of 0.024 to 0.030 and test specificities of 0.843 to 0.859 at the 85%-specificity threshold. Because these specificities differ between models, the sensitivities in Table 6 do not compare models at equal specificity. Confusion matrices at both thresholds are given in Table S2d. At the validation-derived thresholds, late fusion detected 32 more of the 1466 glaucomatous eyes than OCT-only (1124 versus 1092) and produced 17 more false positives among the 1534 normal eyes (234 versus 217). Per 1000 people, this corresponds to about 0.8 additional detections and 10.7 additional false-positive referrals at a prevalence of 3.5%; 2.2 and 10.0 at 10%; and 10.7 and 5.7 at the test prevalence of 48.9%. This trade-off arose mainly because the two models operated at different specificities. At matched specificity, the estimated gain was 0.5 additional detections per 1000 at 3.5% prevalence (95% CI −0.1 to 1.0) and 1.4 at 10% (95% CI −0.3 to 2.7).
The late-fusion improvement remained after adjustment across all three comparisons and when the two secondary comparisons were adjusted separately (Holm-adjusted p = 0.0008). It was also present in the high-specificity region of the ROC curve. At equal specificity, the sensitivity gain was not established. The paired comparisons and post hoc sensitivity analyses are summarized in Table 7.
Table 7. AUROC differences versus OCT-only. The ΔAUROC and its paired-bootstrap 95% CI are the pre-specified comparisons; the unadjusted p-values, the multiplicity adjustment, partial AUROC and the sensitivity analysis with thresholds re-estimated on the test split are post hoc.

3.6. Subgroup Analyses (Post Hoc)

AUROC differed most by race (Table 8). The late-fusion improvement was positive in most subgroups, with intervals excluding zero in the larger ones. Small subgroups such as Hispanic (n = 106) and Spanish-speaking (n = 44) patients had wide intervals and are not interpreted.
Table 8. OCT-only AUROC and late-fusion difference by subgroup.
Across races, the worst-subgroup AUROC was 0.811 for OCT-only, 0.814 for cross-attention, 0.821 for late fusion and 0.830 for concatenation, with ES-AUC of 0.784, 0.806, 0.796 and 0.814, respectively. Part of the smaller gap of the fusion models reflected lower AUROC in Asian patients (0.905 for concatenation and 0.890 for cross-attention).
The lower AUROC in Black patients was not explained by age or severity (Table 9). After age standardization the gap between Black and White patients remained 0.068. Glaucomatous eyes of Black patients had worse VF MD, and sensitivity in moderate and advanced disease was higher than in White patients. In normal eyes, however, the false-positive rate at the validation-derived 85%-specificity threshold was 31.3% (51/163) in Black and 13.1% (162/1238) in White patients, a difference of 18.2 percentage points (95% CI 11.3 to 25.9). The worst MD among the 1534 normal-labeled eyes of the test split was −1.00 dB, so no normal-labeled eye had MD worse than −1 dB; false-positive and true-negative normal eyes had similar MD. In all three races, false-positive normal eyes were older than true-negative ones.
Table 9. Decomposition of the racial disparity (OCT-only, validation-derived 85%-specificity threshold).

4. Discussion

4.1. Principal Findings

In FairVision, OCT carried most of the information needed to detect glaucoma. Jointly trained concatenation and cross-attention fusion did not improve on OCT alone, whereas combining separately trained OCT and SLO models with a small SLO weight gave a small improvement that survived multiplicity adjustment. Models developed on GAMMA did not transfer to FairVision, and post hoc analyses showed lower AUROC among Black patients, accompanied by a higher false-positive rate among normal eyes. MultiFair (arXiv version 3) [14] provides a direct precedent on the same official split: a unimodal three-dimensional OCT ResNet reached an AUROC of 0.833 and a standard jointly trained SLO–OCT ResNet 0.826, with the lowest subgroup AUROC in Black patients, whereas modality-balancing methods reached 0.839–0.845 and the proposed MultiFair method 0.861. Our joint-fusion result agrees with theirs for standard joint fusion, and our ordering of racial subgroups is consistent with that report, although values are not directly comparable because input sampling, training and evaluation procedures differ. The present study adds paired confidence intervals on the same test samples, a protocol that fixed calibration and thresholds before testing, a separately trained late-fusion baseline and a cross-domain analysis. Our test-set conclusion about joint fusion applies to standard joint training; one modality-balancing method was examined on validation only (Section 3.4).

4.2. Cross-Domain Transfer

The E04 failure combined two kinds of shift. The inputs changed in modality, image geometry, intensity and probably the imaged region (Table 4), and the target changed as well: the binary score obtained by summing the GAMMA probabilities for early and progressive glaucoma was trained against GAMMA labels, which are also based on visual-field MD but follow different criteria [4]. In GAMMA, glaucomatous eyes were staged by MD alone and non-glaucoma eyes were drawn from a myopia cohort, without the −3 dB, glaucoma hemifield test and pattern standard deviation requirements that define FairVision labels (Section 2.2). The fundus branch received grayscale SLO images although it had been trained on color photographs, and OCT B-scans differed in aspect ratio and brightness. Two consequences should be distinguished. Ranking performance fell from the source-domain level (out-of-fold AUROC 0.90–0.95) to 0.635–0.653, whereas the original 0.5 operating threshold failed almost completely (sensitivity 0.3–2.4%). The design cannot separate the contributions of input shift and label-definition shift [15]. In a controlled comparison on validation, initializing the E05 models from GAMMA-trained weights left AUROC unchanged relative to ImageNet initialization (differences −0.004 to +0.001, all intervals including zero). This experiment therefore did not demonstrate an additional benefit of GAMMA initialization, and the improvement from E04 to E05 is not attributable to the source weights in this setting; it should not be read as evidence that source-domain pretraining is ineffective in general. This conclusion is limited by the modest adaptation of the source encoders (about 1% relative change in layer 4) and by the remaining differences in evaluation split between E04 and E05 (Table 2).
Cross-attention fusion was worse than concatenation in E04 but not in E05. With datasets and training conditions both changing, this pattern does not establish that one architecture is more sensitive to domain shift.

4.3. Joint Versus Late Fusion

Modality imbalance offers one explanation for the limited benefit of joint fusion: when one modality is much more informative, joint optimization can leave the weaker branch undertrained [12,13]. Our findings are consistent with this, since OCT outperformed SLO, equal-weight late fusion was harmful, and only low-weight late fusion helped. The SLO ablation did not support a simple suppression of SLO. A mismatched SLO image lowered AUROC by 0.023–0.024 in both fusion models, so both used SLO features (Section 3.4). However, a blank SLO image left cross-attention fusion almost unchanged, and concatenation fusion with a blank SLO image fell below OCT-only. Together, these results suggest that SLO contributed little net information in the jointly trained models and that their OCT pathway was not stronger than the separately trained OCT-only model. During training with gradient modulation, the OCT pathway dominated the SLO pathway in almost every step, which shows the imbalance directly. With gradient modulation, concatenation fusion achieved a numerically higher validation AUROC than standard concatenation and an AUROC similar to that of OCT-only. However, neither paired difference was statistically established, and the results do not demonstrate that correcting modality imbalance improves discrimination beyond OCT alone. Other balancing methods exceeded both OCT-only and standard joint fusion on the same split (AUROC up to 0.861) [14], so our conclusion is limited to standard joint training and to the single balancing method and setting tested here.
The late-fusion gain was small. It amounted to 0.006 in AUROC and 0.008 in partial AUROC at high specificity, and the sensitivity difference at equal specificity was not significant. At the validation-derived thresholds, the gain came with lower specificity, which at a screening prevalence would add more false-positive referrals than detections (Section 3.5); at matched specificity, the sensitivity gain was not established. The result therefore supports improved ranking, not clinical benefit, which would require decision-curve analysis and external validation. Its practical value lies in showing that a simple, separately trained combination can extract information that joint fusion missed, and that such a baseline belongs in any evaluation of multimodal architectures. The contrast with human readers, for whom OCT added substantially to fundus photographs [5], suggests that the direction of fusion matters: once a model already uses OCT, a fundus-type image adds little.

4.4. Validation Selection Bias and Analysis Lock

The model that looked best on validation, cross-attention fusion, was the worst of the four on test. Using one validation split for both selection and comparison readily produces differences of this size. Fixing candidates, calibration, thresholds and comparisons before the test evaluation limited analytic flexibility. However, the test split had been analyzed in E04, so the E05 result is not an independent confirmation, and the late-fusion finding requires independent confirmation in another cohort.

4.5. Subgroup Disparities

The lower AUROC in Black patients persisted after age standardization and was accompanied by a higher false-positive rate in normal eyes, whereas sensitivity in glaucomatous eyes was not lower. Because the false-positive rate is measured at one threshold and AUROC summarizes ranking across all thresholds, this pattern does not establish that false positives caused the AUROC gap. Because FairVision defines normal eyes by a normal visual field, functional damage is unlikely to explain these false positives. Structural changes preceding VF loss, normal anatomical variation in optic disc and cup size between populations [26], image quality and other confounders remain possible. We did not measure disc size, cup-to-disc ratio or image quality, so these explanations are hypotheses. False-positive normal eyes were older than true negatives in all three races, suggesting that age-related changes may contribute.
At a common threshold, operating points differed between groups: Black patients had more false positives, and Asian patients had the fewest false positives but the lowest sensitivity in early disease (0.559). Group-specific calibration or fairness-aware training [16,17] could address this, but any use of race at deployment raises ethical questions that require separate consideration.

4.6. Limitations

  • Test reuse: The test split was analyzed in E04 before E05 was designed. E05 candidates were locked before their test evaluation, but the study was not independently registered.
  • Single cohort: E05 was evaluated in one cohort from one institution. Replication in other institutions, devices and periods is needed.
  • Spectrum: FairVision excludes eyes with VF MD between −3 and −1 dB, which may inflate discrimination relative to screening populations.
  • Imaged region: The OCT region of FairVision was inferred, not documented, and the GAMMA region relies on dataset documentation.
  • Source initialization: The comparison of GAMMA and ImageNet initialization used validation only, and the GAMMA source models had adapted their encoders only modestly; stronger source-domain pretraining might behave differently.
  • Input and model scope: Only eight B-scans at 224 × 224 resolution and a ResNet18 backbone were studied. Eight B-scans were used to keep training feasible and to match the source models. Denser sampling could strengthen OCT-only and thereby reduce the late-fusion margin, so results may differ for full 3D volumes, higher resolution or other backbones.
  • Post hoc subgroups: Subgroup analyses were not pre-specified, and small subgroups were imprecise.
  • Reference standard: Labels were taken from the public datasets; their annotation process and rater variability could not be assessed.
  • Multiplicity: Adjustment was applied after the test evaluation, although conclusions were unchanged under both adjustment families.

5. Conclusions

Models developed on GAMMA lost discrimination and produced strongly normal-biased predictions when applied to FairVision. Trained in-domain, OCT alone achieved an AUROC of 0.876, and standard jointly trained fusion with SLO did not improve on it; with one modality-balancing method, examined on validation only, concatenation fusion reached a validation AUROC similar to that of OCT-only, with no statistically established difference. Late fusion with a small, cross-fitted SLO weight produced a small improvement in ranking that remained after multiplicity adjustment. Because the test split had been previously accessed and the sensitivity gain at matched specificity was not established, this result requires independent confirmation and is not evidence of clinical benefit. Lower AUROC among Black patients was accompanied by a higher false-positive rate among normal eyes. These results argue for reporting strong unimodal and late-fusion baselines, external validation and subgroup error analyses when claiming benefits of multimodal fusion.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/diagnostics16233936/s1, Table S1: Locked evaluation protocol (candidates, calibration parameters, thresholds, comparisons and SHA-256 hashes); Table S2: Supplementary statistics (multiplicity adjustment, partial AUROC and sensitivity at matched specificity); Table S3: Subgroup results; Table S4: Components of each architecture that differed from ImageNet initialization and were transferred to E05; Table S5: Probability versus logit fusion on the cross-fitting halves; Table S6: SLO ablation on validation; Table S7: Concatenation fusion with gradient modulation on validation; File S1: CLAIM 2024 reporting crosswalk [27].

Author Contributions

Conceptualization, W.S.K. and H.R.C.; methodology, H.R.C. and W.S.K.; software, H.R.C.; validation, H.R.C. and C.-S.L.; formal analysis, H.R.C.; investigation, H.R.C.; data curation, H.R.C.; writing—original draft preparation, H.R.C.; writing—review and editing, W.S.K. and C.-S.L.; supervision, W.S.K. and C.-S.L.; funding acquisition, W.S.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by the ANCHOR program through the Daejeon ANCHOR Center, funded by the Ministry of Education (MOE) and the Daejeon Metropolitan City, Republic of Korea (2026-ANCHOR-06-001). This work was supported by the National Research Foundation of Korea (NRF) grants funded by the Korea government (MSIT) (RS-2026-25615755). The funders had no role in the design of the study; in the collection, analyses or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Institutional Review Board Statement

Ethical review and approval were waived for this study because it was a secondary analysis of publicly available, de-identified datasets (Harvard-FairVision and GAMMA). Collection of the Harvard-FairVision data was approved by the Institutional Review Board of the originating institution [16].

Data Availability Statement

Harvard-FairVision is available from the Harvard Ophthalmology AI Lab under a CC BY-NC-ND 4.0 license (https://ophai.hms.harvard.edu/datasets/harvard-ef30k (accessed on 23 October 2026)). GAMMA is available from the challenge website (https://gamma.grand-challenge.org/). The datasets are not redistributed by the authors. The analysis code, the locked evaluation protocol and the SHA-256 hashes of all evaluated checkpoints are openly available on GitHub (https://github.com/WSKIM-KYU/glaucoma-slo-oct-fusion (accessed on 23 October 2026)) and archived on Zenodo (https://doi.org/10.5281/zenodo.23757332; release v1.0.0) under the MIT License. The scripts and logs of the post hoc revision analyses, including the SLO ablation and the modality-balancing experiment (Tables S4–S7), are available in the same GitHub repository and archived on Zenodo (https://doi.org/10.5281/zenodo.24361358; release v1.1.0). These analyses were not part of the original locked test protocol, and no additional model was evaluated on the test split. Trained model weights and case-level predictions are not distributed because they are derived from data licensed under CC BY-NC-ND 4.0.

Acknowledgments

During the preparation of this study, the authors used Claude Opus 5.5 (Anthropic, San Francisco, CA, USA) to assist with study design, analysis code, statistical scripts and manuscript drafting, and ChatGPT (GPT-6, OpenAI, San Francisco, CA, USA) to assist with manuscript review and revision. The authors reviewed and verified all outputs, and responsibility for the analyses and the submitted content remains with the authors.

Conflicts of Interest

The authors declare no conflicts of interest. The Guest Editor of this Special Issue is affiliated with the Department of Artificial Intelligence, Konyang University, the same department as W.S.K. The authors have requested that this manuscript be handled by an independent editor, with no involvement of the Guest Editor in its peer review or editorial decision.

Abbreviations

The following abbreviations are used in this manuscript: AUROC, area under the receiver operating characteristic curve; AUPRC, area under the precision–recall curve; CI, confidence interval; ECE, expected calibration error; ES-AUC, equity-scaled AUROC; MD, mean deviation; OCT, optical coherence tomography; pAUC, partial AUROC; SLO, scanning laser ophthalmoscopy; VF, visual field.

References

  1. Tham, Y.C.; Li, X.; Wong, T.Y.; Quigley, H.A.; Aung, T.; Cheng, C.Y. Global prevalence of glaucoma and projections of glaucoma burden through 2040: A systematic review and meta-analysis. Ophthalmology 2014, 121, 2081–2090. [Google Scholar] [CrossRef] [Scilit]
  2. Weinreb, R.N.; Aung, T.; Medeiros, F.A. The pathophysiology and treatment of glaucoma: A review. JAMA 2014, 311, 1901–1911. [Google Scholar] [CrossRef] [Scilit]
  3. Ting, D.S.W.; Pasquale, L.R.; Peng, L.; Campbell, J.P.; Lee, A.Y.; Raman, R.; Tan, G.S.W.; Schmetterer, L.; Keane, P.A.; Wong, T.Y. Artificial intelligence and deep learning in ophthalmology. Br. J. Ophthalmol. 2019, 103, 167–175. [Google Scholar] [CrossRef] [Scilit]
  4. Wu, J.; Fang, H.; Li, F.; Fu, H.; Lin, F.; Li, J.; Huang, Y.; Yu, Q.; Song, S.; Xu, X.; et al. GAMMA challenge: Glaucoma grAding from Multi-Modality images. Med. Image Anal. 2023, 90, 102938. [Google Scholar] [CrossRef] [Scilit]
  5. Watanabe, T.; Hiratsuka, Y.; Kita, Y.; Tamura, H.; Kawasaki, R.; Yokoyama, T.; Kawashima, M.; Nakano, T.; Yamada, M. Combining Optical Coherence Tomography and Fundus Photography to Improve Glaucoma Screening. Diagnostics 2022, 12, 1100. [Google Scholar] [CrossRef] [Scilit]
  6. Thompson, A.C.; Jammal, A.A.; Medeiros, F.A. A review of deep learning for screening, diagnosis, and detection of glaucoma progression. Transl. Vis. Sci. Technol. 2020, 9, 42. [Google Scholar] [CrossRef] [Scilit]
  7. Liu, H.; Li, L.; Wormstone, I.M.; Qiao, C.; Zhang, C.; Liu, P.; Li, S.; Wang, H.; Mou, D.; Pang, R.; et al. Development and validation of a deep learning system to detect glaucomatous optic neuropathy using fundus photographs. JAMA Ophthalmol. 2019, 137, 1353–1360. [Google Scholar] [CrossRef] [Scilit]
  8. Ran, A.R.; Cheung, C.Y.; Wang, X.; Chen, H.; Luo, L.Y.; Chan, P.P.; Wong, M.O.M.; Chang, R.T.; Mannil, S.S.; Young, A.L.; et al. Detection of glaucomatous optic neuropathy with spectral-domain optical coherence tomography: A retrospective training and validation deep-learning analysis. Lancet Digit. Health 2019, 1, e172–e182. [Google Scholar] [CrossRef] [Scilit]
  9. Xiong, J.; Li, F.; Song, D.; Tang, G.; He, J.; Gao, K.; Zhang, H.; Cheng, W.; Song, Y.; Lin, F.; et al. Multimodal machine learning using visual fields and peripapillary circular OCT scans in detection of glaucomatous optic neuropathy. Ophthalmology 2022, 129, 171–180. [Google Scholar] [CrossRef] [Scilit]
  10. Mehta, P.; Petersen, C.A.; Wen, J.C.; Banitt, M.R.; Chen, P.P.; Bojikian, K.D.; Egan, C.; Lee, S.-I.; Balazinska, M.; Lee, A.Y.; et al. Automated detection of glaucoma with interpretable machine learning using clinical data and multimodal retinal images. Am. J. Ophthalmol. 2021, 231, 154–169. [Google Scholar] [CrossRef] [Scilit]
  11. Kihara, Y.; Montesano, G.; Chen, A.; Amerasinghe, N.; Dimitriou, C.; Jacob, A.; Chabi, A.; Crabb, D.P.; Lee, A.Y. Policy-driven, multimodal deep learning for predicting visual fields from the optic disc and OCT imaging. Ophthalmology 2022, 129, 781–791. [Google Scholar] [CrossRef] [Scilit]
  12. Wang, W.; Tran, D.; Feiszli, M. What makes training multi-modal classification networks hard? In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), Seattle, WA, USA, 13–19 June 2020; pp. 12695–12705. [Google Scholar]
  13. Peng, X.; Wei, Y.; Deng, A.; Wang, D.; Hu, D. Balanced multimodal learning via on-the-fly gradient modulation. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), New Orleans, LA, USA, 18–24 June 2022; pp. 8238–8247. [Google Scholar]
  14. Zubair, M.; Zheng, H.; Armstrong, G.W.; Shen, L.Q.; Wilson, G.; Tian, Y.; Zhu, X. MultiFair: Multimodal Balanced Fairness-Aware Medical Classification with Dual-Level Gradient Modulation. IEEE Trans. Med. Imaging 2026, 45, 5041–5058. [Google Scholar] [CrossRef] [Scilit]
  15. Zech, J.R.; Badgeley, M.A.; Liu, M.; Costa, A.B.; Titano, J.J.; Oermann, E.K. Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study. PLoS Med. 2018, 15, e1002683. [Google Scholar] [CrossRef] [Scilit]
  16. Luo, Y.; Khan, M.O.; Tian, Y.; Shi, M.; Dou, Z.; Elze, T.; Fang, Y.; Wang, M. FairVision: Equitable deep learning for eye disease screening via fair identity scaling. arXiv 2023, arXiv:2310.02492. [Google Scholar]
  17. Luo, Y.; Tian, Y.; Shi, M.; Pasquale, L.R.; Shen, L.Q.; Zebardast, N.; Elze, T.; Wang, M. Harvard Glaucoma Fairness: A retinal nerve disease dataset for fairness learning and fair identity normalization. IEEE Trans. Med. Imaging 2024, 43, 2623–2633. [Google Scholar] [CrossRef] [Scilit]
  18. Shi, M.; Luo, Y.; Tian, Y.; Shen, L.Q.; Zebardast, N.; Eslami, M.; Kazeminasab, S.; Boland, M.V.; Friedman, D.S.; Pasquale, L.R.; et al. Equitable artificial intelligence for glaucoma screening with fair identity normalization. npj Digit. Med. 2025, 8, 46. [Google Scholar] [CrossRef] [Scilit]
  19. Tian, Y.; Shi, M.; Luo, Y.; Kouhana, A.; Elze, T.; Wang, M. FairSeg: A large-scale medical image segmentation dataset for fairness learning using segment anything model with fair error-bound scaling. arXiv 2023, arXiv:2311.02189. [Google Scholar]
  20. He, K.; Zhang, X.; Ren, S.; Sun, J. Deep residual learning for image recognition. In Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Las Vegas, NV, USA, 27–30 June 2016; pp. 770–778. [Google Scholar]
  21. Ilse, M.; Tomczak, J.M.; Welling, M. Attention-based deep multiple instance learning. In Proceedings of the 35th International Conference on Machine Learning (ICML), Stockholm, Sweden, 11–13 July 2018; pp. 2127–2136. [Google Scholar]
  22. Platt, J. Probabilistic outputs for support vector machines and comparisons to regularized likelihood methods. In Advances in Large Margin Classifiers; MIT Press: Cambridge, MA, USA, 1999; pp. 61–74. [Google Scholar]
  23. Holm, S. A simple sequentially rejective multiple test procedure. Scand. J. Stat. 1979, 6, 65–70. [Google Scholar]
  24. McClish, D.K. Analyzing a portion of the ROC curve. Med. Decis. Mak. 1989, 9, 190–195. [Google Scholar] [CrossRef] [Scilit]
  25. Hodapp, E.; Parrish, R.K.; Anderson, D.R. Clinical Decisions in Glaucoma; Mosby: St. Louis, MO, USA, 1993. [Google Scholar]
  26. Varma, R.; Tielsch, J.M.; Quigley, H.A.; Hilton, S.C.; Katz, J.; Spaeth, G.L.; Sommer, A. Race-, age-, gender-, and refractive error-related differences in the normal optic disc. Arch. Ophthalmol. 1994, 112, 1068–1076. [Google Scholar] [CrossRef] [Scilit]
  27. Tejani, A.S.; Klontzas, M.E.; Gatti, A.A.; Mongan, J.T.; Moy, L.; Park, S.H.; Kahn, C.E., Jr. CLAIM 2024 Update Panel. Checklist for Artificial Intelligence in Medical Imaging (CLAIM): 2024 update. Radiol. Artif. Intell. 2024, 6, e240300. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.