Skip to Content
DiagnosticsDiagnostics
  • Article
  • Open Access

20 November 2026

15 Pages

Diagnostic Efficiency of Sequential Tissue Acquisition During Shape-Sensing Robotic-Assisted Bronchoscopy in a Thoracic Surgery Setting: A Biopsy-Level Analysis

,
,
and
1
Department of Thoracic Surgery, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany
2
Department of Thoracic Surgery, Helios Clinic Bonn/Rhein-Sieg, 53123 Bonn, Germany
3
Bonn Surgical Technology Center (BOSTER), University Hospital Bonn, Joseph-Schumpeter-Allee 1, 53227 Bonn, Germany
*
Author to whom correspondence should be addressed.
Diagnostics2026, 16(22), 3902;https://doi.org/10.3390/diagnostics16223902 
(registering DOI)
This article belongs to the Special Issue Lung Cancer: Screening, Diagnosis and Management: 2nd Edition

Abstract

Background: Shape-sensing robotic-assisted bronchoscopy (ssRAB) enables precise navigation to peripheral pulmonary lesions, while intraprocedural imaging can improve assessment of biopsy tool positioning relative to the target. However, successful lesion localization does not necessarily translate into diagnostic tissue acquisition, and little is known about the diagnostic contribution of individual sequential biopsy specimens. This study aimed to evaluate the diagnostic yield and sequential tissue acquisition during ssRAB at both the lesion and individual specimen level, with particular emphasis on the number of biopsies required to establish a diagnosis. Methods: We performed a retrospective single-center analysis of consecutive thoracic surgical ssRAB procedures using the ION™ Endoluminal System (Intuitive Surgical, Sunnyvale, CA, USA) between August 2024 and March 2026. Procedures performed exclusively for bronchoscopic lesion marking without diagnostic tissue acquisition were excluded. Intraprocedural imaging was performed using cone-beam computed tomography (CBCT) or C-arm fluoroscopy. Primary outcome measures included specimen-level diagnostic yield, lesion-level diagnostic yield, the biopsy number at which the first diagnostic specimen was obtained, and the diagnostic-to-total specimen ratio per lesion. Results: Eighty-four patients with 118 pulmonary nodules were included. Median lesion diameter was 9.0 mm, and 94 lesions (79.7%) were solid, 10 (8.5%) were subsolid, and 14 (11.9%) were pure ground-glass opacities. CBCT was used in 111 lesions (94.1%) and C-arm fluoroscopy in seven (5.9%). A diagnostic bronchoscopic result was obtained in 101 lesions, corresponding to a lesion-level diagnostic yield of 85.6%. A total of 794 individual biopsy specimens were obtained, of which 487 (61.3%) were diagnostic. The mean diagnostic-to-total specimen ratio per lesion was 0.59 ± 0.39. Among diagnostically successful lesions, the first biopsy specimen was diagnostic in 68/101 cases (67.3%). A diagnosis was established within the first three biopsy specimens in 91/101 lesions (90.1%) and within the first five specimens in 99/101 lesions (98.0%). In two lesions, the first diagnostic specimen was obtained with the eighth biopsy. Conclusions: Although ssRAB achieved a high lesion-level diagnostic yield, diagnostic performance at the individual specimen level was substantially lower. Most successful diagnoses were established within the first three biopsy specimens, while additional sampling continued to provide incremental diagnostic information. These findings highlight the distinction between successful lesion localization and successful tissue acquisition and support a sequential, rather than single-sample, approach to tissue acquisition during ssRAB.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.