Review Reports
- Elisa Capuana *,
- Emmanuel Fortunato Gulino and
- Vincenzo La Carrubba
- et al.
Reviewer 1: Anonymous Reviewer 2: Min Wu
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsThe manuscript entitled “Rheological behavior, filament stability, and microstructure of an extrusion-processable kefiran–PG formulation” submitted by Capuana and colleagues, reports the development of a kefiran-PG system designed to control print fidelity.
Using a variety of characterization methods, including oscillatory strain, frequency and time sweep measurements, ATR-FT-IR, and SEM, the authors demonstrate that this system can function as a time-evolving extrusion ink. This is a particularly important contribution to the rapidly advancing field of additive manufacturing. Notably, the reported system can be tuned after mixing and can preserve its architecture without undergoing rapid fragmentation.
The paper is well-structured; the experiments are systematic and appropriately interpreted. The language is clear, and overall, the paper is coherent and engaging. Moreover, the data presented support the conclusions, and the references align well with the statements discussed in the paper. Therefore, I recommend publishing this paper in Polymers after addressing the minor suggestions indicated below.
Three figures need to be improved.
- Figure 4 shows only one axis but contains information for two axes. The vertical axis should extend only up to 95, not 100, to avoid presenting empty space in the data display.
- Figure 5 needs a larger font, as the current size makes the information difficult to read. The figure should be redesigned to clearly present the data, possibly by labeling the top panel as A and the bottom panel as B and placing on top of each other.
- Figure 7: Use a larger font for better readability. Additionally, present the figure as Panel A (top), Panel B (middle), and Panel C (bottom) to ensure the information is clearly visible.
- Regarding Figure 2 and Figure 3, the first sentence title “Cross-sectional SEM images of freeze-dried kefiran–PG constructs” is the same in both, giving the first impression that these images are presenting same information. Maybe this sentence should be modified so that it already clearly presents what is different between the two figures from line one.
Comments for author File:
Comments.pdf
Author Response
Reviewer 1
The manuscript entitled “Rheological behavior, filament stability, and microstructure of an extrusion-processable kefiran–PG formulation” submitted by Capuana and colleagues, reports the development of a kefiran-PG system designed to control print fidelity.
Using a variety of characterization methods, including oscillatory strain, frequency and time sweep measurements, ATR-FT-IR, and SEM, the authors demonstrate that this system can function as a time-evolving extrusion ink. This is a particularly important contribution to the rapidly advancing field of additive manufacturing. Notably, the reported system can be tuned after mixing and can preserve its architecture without undergoing rapid fragmentation.
The paper is well-structured; the experiments are systematic and appropriately interpreted. The language is clear, and overall, the paper is coherent and engaging. Moreover, the data presented support the conclusions, and the references align well with the statements discussed in the paper. Therefore, I recommend publishing this paper in Polymers after addressing the minor suggestions indicated below.
Three figures need to be improved.
- Figure 4 shows only one axis but contains information for two axes. The vertical axis should extend only up to 95, not 100, to avoid presenting empty space in the data display.
Author’s response: Thank you for your careful observation regarding Figure 4. You are absolutely right about both aspects that you have highlighted. We have corrected the figure according to the indications given. The updated version of Figure 4 is now included in the revised manuscript.
- Figure 5 needs a larger font, as the current size makes the information difficult to read. The figure should be redesigned to clearly present the data, possibly by labeling the top panel as A and the bottom panel as B and placing on top of each other.
Author’s response: Thanks for the suggestion on Figure 5. We fully agree that readability was compromised by the small font size. We have redesigned the figure following your instructions.
- Figure 7: Use a larger font for better readability. Additionally, present the figure as Panel A (top), Panel B (middle), and Panel C (bottom) to ensure the information is clearly visible.
Author’s response: Thank you for your feedback on Figure 7. We increased the font size to improve readability and rearranged the figure by arranging the three panels vertically.
- Regarding Figure 2 and Figure 3, the first sentence title “Cross-sectional SEM images of freeze-dried kefiran–PG constructs” is the same in both, giving the first impression that these images are presenting same information. Maybe this sentence should be modified so that it already clearly presents what is different between the two figures from line one.
Author’s response: Thank you for that comment. However, we would respectfully clarify that the captions in Figures 2 and 3 are already distinct from the first sentence: Figure 2: "Cross-sectional SEM images of freeze-dried kefiran–PG constructs..." and Figure 3: "Surface SEM images of freeze-dried kefiran–PG constructs...". We understand that the similar structure of the sentences may have generated confusion at first reading. If you feel that the distinction can be made even more immediate, we are open to further emphasizing the difference between cross-sectional analysis and surface morphology already in the first line of each caption.
Reviewer 2 Report
Comments and Suggestions for AuthorsReviewer Comments on the Manuscript: “Rheological behavior, filament stability, and microstructure of 2 an extrusion-processable kefiran–PG formulation”.
This study develops a kefiran–propylene glycol (PG) formulation for extrusion-based additive manufacturing, enabling control over print fidelity through time-dependent supramolecular reorganization. The research concept is clear and the experimental design is largely comprehensive. However, several aspects require improvement, including the description of experimental details, data presentation, and depth of discussion. A major revision is required before the manuscript can be resubmitted for rereview. My detailed comments and suggestions are as follows:
- Line 29:The authors are encouraged to explicitly articulate, toward the end of the Introduction, the anticipated molecular-level role of PG in modulating hydrogen-bonding equilibria, beyond its nominal function as a “processing aid”.
- Line 119: The kefiran-to-PG mass ratio was set at 4:1, but the authors do not specify whether this was derived from preliminary screening or literature precedent.
- Lines 344-345:The apparent porosity was calculated as 60.9±2%. The authors appropriately acknowledge ice-templating effects from freeze-drying in the Discussion; however, the Results section would benefit from addressing whether extrusion shear induces pore orientation.
- Lines 393-394:The authors attribute enhanced absorption in the 2920–2850 cm⁻¹ region to PG incorporation. A control spectrum of pure PG is recommended to exclude potential interference from lipid contaminants that may persist following extraction.
- Line 541: The conclusions are overly general. The authors are advised to incorporate specific data driven recommendations, such as an optimal post mixing waiting time for printing, and to articulate concrete prospects for biomedical or food related applications.
- The experiments utilized two needle gauges, 20 G and 23 G. However, the subsequent results (e.g., Figure 1 and Figure 4) do not specify which gauge was employed for each dataset. Given that nozzle inner diameter alters shear rate and consequently affects microstructure and porosity, this information must be clearly stated.
- The authors should ensure consistent formatting for mathematical symbols and physical quantities (e.g., G', G''), preferably in italics, as mixed formatting appears throughout the manuscript.
- There are multiple grammatical errors and inappropriate word choices throughout the manuscript. Please review the entire text, correct these issues, and refine the language for accuracy and clarity.
9.Check and standardize the reference formatting throughout the manuscript.
Author Response
Reviewer 2
Reviewer Comments on the Manuscript: “Rheological behavior, filament stability, and microstructure of 2 an extrusion-processable kefiran–PG formulation”.
This study develops a kefiran–propylene glycol (PG) formulation for extrusion-based additive manufacturing, enabling control over print fidelity through time-dependent supramolecular reorganization. The research concept is clear and the experimental design is largely comprehensive. However, several aspects require improvement, including the description of experimental details, data presentation, and depth of discussion. A major revision is required before the manuscript can be resubmitted for rereview. My detailed comments and suggestions are as follows:
- Line 29:The authors are encouraged to explicitly articulate, toward the end of the Introduction, the anticipated molecular-level role of PG in modulating hydrogen-bonding equilibria, beyond its nominal function as a “processing aid”.
Author’s response: Thank you for this valuable tip. We have expanded the last paragraph of the Introduction to explain the anticipated molecular mechanism of propylene glycol in the modulation of hydrogen binding equilibria of kefiran. Specifically, we described how PG competes with water molecules for hydrogen binding sites along the kefiran chain, acting as a molecular regulator that balances processability and structural stabilization. This integration now provides a solid scientific rationale for the role of the PG that goes far beyond its nominal function of "processing aid".
2. Line 119: The kefiran-to-PG mass ratio was set at 4:1, but the authors do not specify whether this was derived from preliminary screening or literature precedent.
Author’s response: Thank you for highlighting this important gap. The kefiran-PG mass ratio of 4:1 was not chosen arbitrarily, but derives from a systematic optimization conducted in our previous work (Sabatino et al., Int. J. Biol. Macromol. 2020, 149, 309–319), in which different kefiran-PG formulations were evaluated to identify optimal proportions to obtain stable and structurally cohesive gels. We have modified the text at line 119 (line 126 in the revised manuscript) to explicitly include this reference and clarify the scientific origin of the choice of this specific composition ratio.
3. Lines 344-345:The apparent porosity was calculated as 60.9±2%. The authors appropriately acknowledge ice-templating effects from freeze-drying in the Discussion; however, the Results section would benefit from addressing whether extrusion shear induces pore orientation.
Author’s response: Thank you for this very pertinent observation. In the Results section, we have supplemented the paragraph on porosity by adding a qualitative assessment of pore orientation based on visual inspection of cross-sectional SEM images. As now specified in the text, we did not observe an evident preferential orientation of pores along the extrusion direction, which suggests that the dominant mechanism in microstructure formation is ice-templating during freeze-drying rather than shear-induced alignment during processing.
4. Lines 393-394:The authors attribute enhanced absorption in the 2920–2850 cm⁻¹ region to PG incorporation. A control spectrum of pure PG is recommended to exclude potential interference from lipid contaminants that may persist following extraction.
Author’s response: We fully agree that a reference spectrum of pure PG is necessary. In the revised manuscript, the ATR–FTIR spectrum of pure PG has been included in Figure 6. The Results and Discussion sections have been revised accordingly.
5. Line 541: The conclusions are overly general. The authors are advised to incorporate specific data driven recommendations, such as an optimal post mixing waiting time for printing, and to articulate concrete prospects for biomedical or food related applications.
Author’s response: Thank you for that constructive remark. We have completely revised the Conclusions to make them more specific and application-oriented, incorporating: (1) a quantitative operational recommendation based on filament collapse analysis (optimal waiting time of 15 minutes), (2) concrete and articulated application perspectives for the biomedical and food sectors, directly related to the demonstrated properties, and (3) future directions targeted for specific target applications. The conclusions now provide readers with practical recommendations based on our experimental data and a clear view of the application potential of the developed system.
6. The experiments utilized two needle gauges, 20 G and 23 G. However, the subsequent results (e.g., Figure 1 and Figure 4) do not specify which gauge was employed for each dataset. Given that nozzle inner diameter alters shear rate and consequently affects microstructure and porosity, this information must be clearly stated.
Author’s response: Thank you for highlighting this crucial methodological gap. You're absolutely right: the inner diameter of the needle determines the shear rate during extrusion and can significantly influence the microstructure, the orientation of the polymer chains, and the final porosity of the constructs. To eliminate any ambiguity, we confirm that all experiments and data presented in this manuscript (including those in Figures 1-4) were obtained using only a 20 G needle (0.60 mm inner diameter). The needle 23 G mentioned in the original version had been used only in preliminary tests not included in this work.
7. The authors should ensure consistent formatting for mathematical symbols and physical quantities (e.g., G', G''), preferably in italics, as mixed formatting appears throughout the manuscript.
Author’s response: Thank you for noticing these formatting inconsistencies. We have revised the entire manuscript to standardize the notation: all mathematical symbols and physical quantities (G', G'', δ, L,…) are now italicized, while the units of measurement (Pa, mm, s, °C, Hz) remain in normal format according to SI conventions. Correction has been systematically applied to the main text and figure captions,
8. There are multiple grammatical errors and inappropriate word choices throughout the manuscript. Please review the entire text, correct these issues, and refine the language for accuracy and clarity.
Author’s response: Thank you for this careful observation. We have conducted a systematic linguistic review of the entire manuscript, paying particular attention to the aspects you have pointed out. The revision covered several areas: correction of inaccurate grammatical constructions, elimination of redundancies and repetitions and improvement of terminological consistency.
9. Check and standardize the reference formatting throughout the manuscript.
Author’s response: We thank the Reviewer for this comment. All references have been carefully checked and corrected to comply with the MDPI Polymers style guidelines.
Round 2
Reviewer 2 Report
Comments and Suggestions for AuthorsReviewer Comments on the Manuscript: “Rheological behavior, filament stability, and microstructure of an extrusion-processable kefiran–PG formulation”.
This study investigates the rheological behavior, filament stability, and microstructure of an extrusion-processable kefiran–propylene glycol (PG) formulation. The experimental design is scientifically rigorous, with standardized data acquisition and adequate supporting evidence. The research rationale is clear, demonstrating strong innovation and practical value, and the manuscript generally meets publication standards. Upon review, no fundamental issues were identified in the core content. However, minor refinements are needed regarding detail presentation, formatting consistency, and nomenclature uniformity. Therefore, the authors are advised to address the following specific points, after which the manuscript may be accepted for publication:
- Line 127: An unnecessary paragraph marker appears before the sentence. Please check the entire manuscript and remove all redundant markers.
- Lines 344–345: Please unify the decimal precision of the porosity value (60.9±2%) to be consistent with the number of decimal places used for other statistical values throughout the manuscript.
- Upon checking, no error bars are present in any of the figures in the manuscript. Considering the variability of the experimental data, error bars can intuitively reflect the reliability and repeatability of the data. We suggest that the authors add error bars to the relevant quantitative analysis figures (e.g., figures involving numerical statistics and comparisons between groups) to ensure the standard presentation of the data.
- Check and standardize the reference formatting throughout the manuscript.
Author Response
1. Line 127: An unnecessary paragraph marker appears before the sentence. Please check the entire manuscript and remove all redundant markers.
Authors’ response: Thank you for this careful observation. We have removed the redundant paragraph marker appearing at line 127. A thorough review of the full text was also conducted to identify and eliminate all similar formatting artifacts. No other superfluous paragraph markers were found.
2. Lines 344–345: Please unify the decimal precision of the porosity value (60.9±2%) to be consistent with the number of decimal places used for other statistical values throughout the manuscript.
Authors’ response: Thank you for this observation. We would like to clarify that the porosity value as reported in the manuscript is 60.9 ± 1.2%, expressed with one decimal place for both the mean and the standard deviation. The level of decimal precision used is consistent with all other statistical values throughout the manuscript (e.g., normalized deflection values, swelling ratios, and mass loss percentages). No revision is necessary on this point, but we have verified that the value is correctly displayed in the revised manuscript.
3. Upon checking, no error bars are present in any of the figures in the manuscript. Considering the variability of the experimental data, error bars can intuitively reflect the reliability and repeatability of the data. We suggest that the authors add error bars to the relevant quantitative analysis figures (e.g., figures involving numerical statistics and comparisons between groups) to ensure the standard presentation of the data.
Authors’ response: We thank the reviewer for this suggestion. We would like to respectfully clarify that error bars representing mean ± standard deviation (n = 3) are already present in all figures involving quantitative replicate measurements, specifically in Figure 1C (normalized mid-span deflection) and Figure 5A–B (swelling ratio and apparent mass loss). This is also explicitly stated in the respective figure captions. Figure 4 displays a frequency distribution histogram of pore diameters derived from image analysis; in this context, error bars on individual bins are not standard practice, as the histogram represents the full measured distribution rather than replicate group means. Figure 7 presents rheological sweep measurements (strain, frequency, and time sweeps). These are continuous instrumental traces recorded on a single representative sample per condition, as is standard in rheological characterization of viscoelastic materials. We therefore consider that the manuscript already meets standard requirements for error bar reporting in all relevant quantitative figures.
4. Check and standardize the reference formatting throughout the manuscript.
Authors’ response: Thank you for this comment. We have conducted a thorough audit of all 70 references and standardized their formatting in accordance with MDPI Polymers guidelines.