Review Reports
- Hazal Deniz Kose 1 and
- Lezize Sebnem Turkun 2,*
Reviewer 1: Anonymous Reviewer 2: Anonymous Reviewer 3: Anonymous
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsThe manuscript compares two bioactive and two conventional dental resin composites: Stela automix (SA), Activa Presto (AP), Tetric N-Ceram 2 (TN) and Filtek Supreme (FS). The authors measure Vickers microhardness, nanoindentation and elastic modulus of 15 independently prepared samples for each resin composite.
The main finding of the study is that, AP resin composite has the lowest microhardness, nano hardness and elastic modulus compared to the other composites, while FN and TS show relatively similar hardness values. The findings presented in the manuscript are interesting by themselves and supported by comprehensive statistical testing, but there are issues which limit the conclusions of the manuscript.
1- First of all, the title of the manuscript asks the research question “Do Bioactive Resin Composites Differ Mechanically from Conventional Ones?” The title relates the observed differences between the composites to bioactivity. However, there are inherent differences between the composites (as depicted in Table 1). The observed differences among four different composites, are not the isolated effect of bioactivity on mechanical properties. Several parameters such as chemical composition, filler characteristic and content, polymerization technique, etc. differ between the composites. Each of these parameters can significantly affect the mechanical properties especially, filler characteristic and content. Additionally, the polishing step may affect surface roughness of each resin composite differently than others. Therefore, I believe the relevance of bioactivity to mechanical properties is not conclusively demonstrated.
I suggest a general revision to the manuscript title and any claim made in the manuscript about the relation of bioactivity to mechanical properties. Present the manuscript as a study of the mechanical properties of these commercial resin composites.
2- The authors describe the nanoindentation method in lines 136-140 of the manuscript, but the description is insufficient. The authors need to explain in detail, how the elastic moduli were measured. Moreover, it is necessary to report loading and unloading times and explain the fitting method for loading/unloading curves to obtain elastic modulus. The authors mention in line 322 of the manuscript that “Oliver-Pharr method, used to calculate hardness and elastic modulus from nanoindentation data”. However, they fail to define this method in Materials and Methods section of the manuscript.
3- The authors claim that lower modulus and weak correlation between Vickers microhardness and nanoindentation for AP resin composite is related to the viscoelastic deformation of this sample (lines 322-334). However, it should be noted that the other three resin samples also possess polymeric phases with viscoelastic deformation behaviors. That is why in my previous comment I urged the authors to report loading and unloading time for their measurements. Because all the resin composite samples can technically behave as viscoelastic materials. Therefore, this claim without appropriate dynamic mechanical testing is unproven.
4- Including some representative force-displacement curves, and a few images of the indentation demarcation on the surface of the composites will strengthen the manuscript, in my opinion.
Moreover, please add statistical significance signs on the figures, so the reader can distinguish significant differences between samples just by looking at the figures.
Author Response
Comment 1- First of all, the title of the manuscript asks the research question “Do Bioactive Resin Composites Differ Mechanically from Conventional Ones?” The title relates the observed differences between the composites to bioactivity. However, there are inherent differences between the composites (as depicted in Table 1). The observed differences among four different composites, are not the isolated effect of bioactivity on mechanical properties. Several parameters such as chemical composition, filler characteristic and content, polymerization technique, etc. differ between the composites. Each of these parameters can significantly affect the mechanical properties especially, filler characteristic and content. Additionally, the polishing step may affect surface roughness of each resin composite differently than others. Therefore, I believe the relevance of bioactivity to mechanical properties is not conclusively demonstrated.
I suggest a general revision to the manuscript title and any claim made in the manuscript about the relation of bioactivity to mechanical properties. Present the manuscript as a study of the mechanical properties of these commercial resin composites.
Response 1: We thank the reviewer for this important comment. The tested materials differ in filler characteristics and content, monomer composition, and polymerization mode; therefore, as you also mentioned, the observed differences cannot be attributed to bioactivity as an isolated factor. Accordingly, the title has been changed to “Mechanical Characterization of Two Bioactive and Two Conventional Resin Composites Using Vickers Micro-Hardness and Nanoindentation”, and the Abstract, Aim, Discussion, and Conclusions have been revised to present the work as a characterization of four commercial resin composites. Statements implying a causal relationship between bioactivity and mechanical properties have been removed or rephrased, and the Limitations section now addresses compositional differences, polymerization mode, and the possible influence of polishing on surface finish.
Comment 2- The authors describe the nanoindentation method in lines 136-140 of the manuscript, but the description is insufficient. The authors need to explain in detail, how the elastic moduli were measured. Moreover, it is necessary to report loading and unloading times and explain the fitting method for loading/unloading curves to obtain elastic modulus. The authors mention in line 322 of the manuscript that “Oliver-Pharr method, used to calculate hardness and elastic modulus from nanoindentation data”. However, they fail to define this method in Materials and Methods section of the manuscript.
Response 2: We thank the reviewer for this comment. The description of the nanoindentation procedure has been expanded in the Materials and Methods section. Indentations were performed using a trapezoidal load function consisting of a 5 s loading segment to a peak load of 6000 µN (1200 µN/s), a 2 s holding segment at peak load, and a 5 s unloading segment (1200 µN/s). The Oliver–Pharr method is now defined in the Materials and Methods section: nano-hardness and elastic modulus were calculated from the unloading segment of the load–depth curves, which was fitted with a power-law function to obtain the contact stiffness, contact depth, and projected contact area. The corresponding equations have also been provided (pages 5–6, lines 174–188).
Comment 3- The authors claim that lower modulus and weak correlation between Vickers microhardness and nanoindentation for AP resin composite is related to the viscoelastic deformation of this sample (lines 322-334). However, it should be noted that the other three resin samples also possess polymeric phases with viscoelastic deformation behaviors. That is why in my previous comment I urged the authors to report loading and unloading time for their measurements. Because all the resin composite samples can technically behave as viscoelastic materials. Therefore, this claim without appropriate dynamic mechanical testing is unproven.
Response 3: We thank the reviewer for this valuable comment and agree that all tested materials contain polymeric phases and may therefore exhibit viscoelastic behavior. As viscoelastic properties were not assessed by dynamic mechanical testing in the present study, the attribution of the lower modulus and weaker method agreement of AP to viscoelastic deformation is not supported by our data. Accordingly, the relevant statements in the Discussion have been revised to present viscoelasticity only as a possible explanation, explicitly noting that all tested materials may behave viscoelastically. The loading, holding, and unloading times of the nanoindentation protocol have been added to the Materials and Methods section (see our response to Comment 2), and the absence of viscoelastic characterization has been added as a limitation of the study (page 15, lines 399-412; page 19, lines 611-617).
Comment 4- Including some representative force-displacement curves, and a few images of the indentation demarcation on the surface of the composites will strengthen the manuscript, in my opinion.
Moreover, please add statistical significance signs on the figures, so the reader can distinguish significant differences between samples just by looking at the figures.
Response 4: We thank the reviewer for this valuable suggestion. Representative load–depth curves have been added (Figure 5). For each material, the curve of the indentation whose nano-hardness and elastic modulus values were closest to the group mean is presented. Unfortunately, images of the indentation impressions were not obtained during testing; this has been acknowledged as a limitation of the study (page 19, lines 617-618). We greatly appreciate this suggestion and will ensure that such images are obtained and reported in our future nanoindentation studies.
As suggested, letters indicating statistically significant differences between materials have been added to Figures 2–4, and the corresponding explanations have been included in the figure captions.
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsThis paper study compared two bioactive (Stela Automix, SA; Activa Presto, AP) and two conventional (Tetric N-Ceram 2, TN; Filtek Supreme Flowable, FS) resin composites using Vickers micro-hardness and nanoindentation. The references provided in this paper indicate that these studies on the samples listed have been already done by previous investigations and almost same results are reproduced here. The discussion portion also confirms that the previous studies on these samples concluded same interpretations and this study reaffirms. It is not clear what is new in the present study. It is important to show what has been done previously, what the present study target, and what is new the present study provides.
Comments for author File:
Comments.pdf
Author Response
Comment 1- This paper study compared two bioactive (Stela Automix, SA; Activa Presto, AP) and two conventional (Tetric N-Ceram 2, TN; Filtek Supreme Flowable, FS) resin composites using Vickers micro-hardness and nanoindentation. The references provided in this paper indicate that these studies on the samples listed have been already done by previous investigations and almost same results are reproduced here. The discussion portion also confirms that the previous studies on these samples concluded same interpretations and this study reaffirms. It is not clear what is new in the present study. It is important to show what has been done previously, what the present study target, and what is new the present study provides.
Response 1: We thank the reviewer for this important comment. We agree that the novelty of the study was not clearly stated in the original manuscript. We would respectfully note that most of the previous studies cited in the original Discussion evaluated different materials (e.g., Activa BioACTIVE Restorative rather than Activa Presto) or different properties (e.g., flexural or compressive strength) and were used to provide context rather than to indicate that the present measurements had already been performed. Previous studies on the tested materials have mainly focused on macroscale properties, and most of the available data on Activa products concern the resin modified glass ionomer formulation, Activa BioACTIVE Restorative. Evidence on the nanoscale mechanical behavior of SA and AP is scarce, and the correspondence between their micro- and nanoscale hardness values has not yet been adequately addressed. The Introduction has been revised to define the specific research gap and state the aim of the study more clearly, and a statement on the contribution of the present findings has been added to the Discussion (page 2-3, lines 78-93; page 13, lines 335-337). In addition, statements in the Discussion that implied agreement with previous studies of other Activa products have been corrected (see also our response to Reviewer 3, Comment 5).
Reviewer 3 Report
Comments and Suggestions for AuthorsDear Authors,
The manuscript presents a comparison of the mechanical properties of four restorative composites using Vickers micro-hardness and nanoindentation. Some methodological details need clarification, and several interpretations should be reconsidered. The contribution to the existing literature also needs to be explained more clearly. My comments are listed below.
- Previous studies could be discussed in more detail to support the stated research gap. In particular, please clarify whether these materials have previously been compared using either method and what additional information is expected from their combined use (lines 71-78).
- Please provide more details of the nanoindentation procedure, including the loading and unloading rates and holding time at peak load. The Oliver–Pharr method mentioned in the Discussion should also be specified here. Please clarify whether the reported modulus is the reduced modulus or Young’s modulus and, if the latter, state the Poisson’s ratio used. (lines 136–140).
- Please clarify how the five nanoindentation sites were selected on each specimen and how they were positioned relative to the Vickers impressions, since both tests were performed on the same surface (lines 128–140).
- Please describe how the specimens were handled after removal from water and before mechanical testing, including any drying procedure and the time between removal and measurement (lines 123–140).
- Reference [7] evaluated Activa Bioactive Restorative, not Activa Presto. Please correct the statement in lines 335–336 and make clear that the cited findings concern a different product.
- Please discuss the possible reasons for AP’s behavior more cautiously. Viscoelasticity, filler–matrix adhesion, and microvoid formation were not measured in this study, so their contribution remains uncertain (lines 322–345 and 364–383).
- Strong correlations do not establish that the two methods are interchangeable. Likewise, the non-significant correlation for AP does not necessarily mean that they provide different information, particularly with only 15 specimens per material. Please revise these interpretations (lines 400-411).
Best regardes.
Author Response
Comment 1- Previous studies could be discussed in more detail to support the stated research gap. In particular, please clarify whether these materials have previously been compared using either method or what additional information is expected from their combined use (lines 71-78).
Response 1: We thank the reviewer for this suggestion. The Introduction has been revised to clarify the research gap. Previous studies on the tested materials have mainly focused on macroscale properties, and most of the available data on Activa products concern the resin modified glass ionomer formulation, Activa BioACTIVE Restorative, rather than Activa Presto. Evidence on the nanoscale mechanical behavior of SA and AP is scarce, and the correspondence between their micro- and nanoscale hardness values has not yet been adequately addressed. We have also clarified the additional information expected from the combined use of the two methods: nanoscale hardness and elastic modulus data for these materials, and an assessment of the consistency between micro- and nanoscale hardness measurements for each material (page 2-3, lines 78-93).
Comment 2- Please provide more details of the nanoindentation procedure, including the loading and unloading rates and holding time at peak load. The Oliver–Pharr method mentioned in the Discussion should also be specified here. Please clarify whether the reported modulus is the reduced modulus or Young’s modulus and, if the latter, state the Poisson’s ratio used. (lines 136–140).
Response 2: We thank the reviewer for this comment. The nanoindentation procedure has been described in more detail in the Materials and Methods section. Indentations were performed at a loading and unloading rate of 1200 µN/s (5 s each) to a peak load of 6000 µN, with a holding time of 2 s at peak load. The Oliver–Pharr method, previously mentioned only in the Discussion, is now specified in the Materials and Methods section. The reported modulus is the reduced elastic modulus (Er) obtained directly from the Oliver–Pharr analysis; as the Poisson’s ratios of the tested materials were not determined, Er was not converted to Young’s modulus. This has been clarified in the Materials and Methods section, where it is also stated that Er is referred to as “elastic modulus” throughout the manuscript for brevity (pages 5–6, lines 174–188).
Comment 3- Please clarify how the five nanoindentation sites were selected on each specimen and how they were positioned relative to the Vickers impressions, since both tests were performed on the same surface (lines 128–140).
Response 3: We thank the reviewer for this comment. The positioning of the indentations has now been clarified in the Materials and Methods section, and a schematic illustration has been added (Figure 1). The specimen surface was divided into two halves: nanoindentation was performed first at five randomly selected points within one half, and on the following day, five Vickers indentations were made in the opposite half, with a minimum distance of 1 mm between adjacent impressions. Since nanoindentation was performed before Vickers testing and the two tests were conducted in separate areas of the surface, interference between the two measurements could be avoided (page 4, 5; lines 156-165).
Comment 4- Please describe how the specimens were handled after removal from water and before mechanical testing, including any drying procedure and the time between removal and measurement (lines 123–140).
Response 4: We thank the reviewer for this comment. The handling of the specimens before testing has now been described in detail in the Materials and Methods section. At the end of the one-week storage period, the specimens were removed from distilled water, gently blotted dry with absorbent paper, and subjected to nanoindentation on the same day. The specimens were then re-immersed in distilled water at 37°C to allow recovery of any water lost during nanoindentation testing, and Vickers micro-hardness was measured on the following day after the same blot-drying procedure. Nanoindentation was performed first to avoid any influence of the larger Vickers impressions on the surrounding surface. This sequence and timing were applied identically to all specimens and material groups. In addition, the description of Vickers micro-hardness testing has been moved after that of nanoindentation to reflect the actual testing sequence (page 4-5, lines 147-160).
Comment 5- Reference [7] evaluated Activa Bioactive Restorative, not Activa Presto. Please correct the statement in lines 335–336 and make clear that the cited findings concern a different product.
Response 5: We thank the reviewer for pointing out this error. The reviewer is correct that reference [7] evaluated Activa BioACTIVE Restorative instead of Activa Presto. The sentence has been revised to state clearly that the cited findings concern a different product from the same manufacturer and cannot be directly extrapolated to AP (page 15, lines 420-427). The other citations of reference [7] in the manuscript, which refer to the study design and to the variability among bioactive materials, have been checked and correctly identify the tested product.
Comment 6- Please discuss the possible reasons for AP’s behavior more cautiously. Viscoelasticity, filler–matrix adhesion, and micro-void formation were not measured in this study, so their contribution remains uncertain (lines 322–345 and 364–383).
Response 6: We thank the reviewer for this valuable comment and totally agree that viscoelasticity, filler–matrix adhesion, and micro-void formation were not measured in the present study. Accordingly, the relevant paragraphs of the Discussion have been revised to present these mechanisms only as possible explanations, and statements indicating that they were responsible for the behavior of AP have been removed. It is now explicitly stated that their contribution remains uncertain and requires further investigation (page 16-17; lines 455-495). The interpretation regarding viscoelasticity has also been revised in response to Reviewer 1, Comment 3, and the absence of viscoelastic characterization has been added to the limitations of the study.
Comment 7- Strong correlations do not establish that the two methods are interchangeable. Likewise, the non-significant correlation for AP does not necessarily mean that they provide different information, particularly with only 15 specimens per material. Please revise these interpretations (lines 400-411).
Response 7: We thank the reviewer for this important comment and fully agree. Correlation does not establish agreement or interchangeability between methods, and the non-significant correlation observed for AP may reflect the limited number of specimens per material rather than a true difference in the information captured by the two methods. Accordingly, the statement suggesting that the two methods may be interchangeable has been removed, and the interpretation of the findings for AP has been revised to acknowledge the limited sample size and to recommend further investigation. We have also noted that the strong pooled correlation is likely to be largely driven by between-material differences. In addition, the following paragraph discussing the practical implications of combining both methods has been shortened accordingly. The limited sample size for within-material correlation analyses has also been added to the limitations of the study (page 16-17, lines 512-549; page 19, lines 613-617).
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsAfter carefully reading the revised version of the manuscript and the authors' reply to my previous comments, I find that the manuscript has improved significantly and the reply from the authors addresses my previous concerns and doubts regarding the manuscript. I only have one minor comment for the authors:
The manuscript finds that there was no statistically significant difference between the hardness of SA and TN samples. Throughout the manuscript the authors claim that these two samples had "comparable" hardness (Discussion section line 330, line 334, Conclusion #3). A lack of statistical significance however, does not mean that these samples performed "comparably" or "did not differ". It only means that under the test conditions here, the differences were not large enough to matter. I urge the authors to correct this wording in the manuscript.
Author Response
Comment 1: The manuscript finds that there was no statistically significant difference between the hardness of SA and TN samples. Throughout the manuscript the authors claim that these two samples had "comparable" hardness (Discussion section line 330, line 334, Conclusion #3). A lack of statistical significance, however, does not mean that these samples performed "comparably" or "did not differ". It only means that under the test conditions here, the differences were not large enough to matter. I urge the authors to correct this wording in the manuscript.
Response 1: We thank the reviewer for this valuable comment and fully agree. The absence of a statistically significant difference does not establish that two materials performed comparably; it only indicates that any difference was not large enough to be detected under the present test conditions. Accordingly, all statements describing the hardness of SA and TN as “comparable”, “similar”, or “not different” have been revised throughout the manuscript to state that no statistically significant difference was detected between the two materials (Discussion, page 12, lines 329-351; page 13, 402-404; page 15, 480-481; Conclusions 2 and 3, page 16, lines 531-539). In addition, a sentence has been added to the Discussion explicitly noting that the absence of a statistically significant difference does not establish equivalence between the materials (page 12, lines 331-332).
Author Response File:
Author Response.pdf
Reviewer 3 Report
Comments and Suggestions for AuthorsDear Authors,
Thank you for your detailed responses and for incorporating my suggestions into the revised manuscript. All my comments have been addressed, and I have no further comments.
Best regards,
Reviewer
Author Response
Dear Authors,
Thank you for your detailed responses and for incorporating my suggestions into the revised manuscript. All my comments have been addressed, and I have no further comments.
Best regards,
Reviewer
Response: Thank you dear reviewer for your contribution and for improving our manuscript.