Reviewer 1 Report
Comments and Suggestions for AuthorsThe manuscript entitled “Real-Time Single-Cell Measurement and Kinetic Modeling of Daunorubicin Uptake in Multidrug Resistant Leukemia Cells Using a Microfluidic Biochip” developed a microfluidic biochip for real-time single-cell analysis of daunorubicin (DNR) uptake. It revealed distinct kinetic behaviors between drug-sensitive leukemia cells and multidrug-resistant cells overexpressing P-glycoprotein, with the latter requiring a two-process uptake model. The study uncovered substantial cell-to-cell heterogeneity that masked inhibitor effects at the population level, but a same-single-cell analysis approach demonstrated enhanced intracellular DNR retention and accelerated uptake following multidrug resistance inhibition. This work is novel in overcoming the limitations of the conventional population-averaged measurements. Besides, the findings from this work highlight the importance of single-cell kinetic profiling for improving therapeutic evaluation and developing more effective strategies to overcome chemotherapy resistance. The data amount is sufficient to support the key conclusions of this research. Considering the above-mentioned merits, I recommend that this manuscript be accepted for publication in Pathophysiology, provided that the authors adequately address the concerns outlined below.
#1 Please give descriptions regarding the significance of this work in the Introduction section. Usually, it is necessary to talk about the work significance in the introduction section. The reviewer failed to clearly catch the significance of this work in the introduction section. To help readers with better understanding of this research, please add one or two sentences in the final paragraph of the Introduction section regarding the research significance.
#2 Please give more details to Figure 1 to promote its readability. It is really difficult to understand the intention of the authors regarding the drug uptake measurement. Please add more details to aid in understanding the measurement process. Also, it would be more considerate to provide the real research equipment (microfluidic platform) used for the measurement.
#3 Please add the time information to Figure 2. The authors describe time-lapse sequence of single-cell capture and retention within the microfluidic biochip. It is recommended to give time gap between to neighboring images. Or the authors may consider add another merger image to this figure, showing the cell moving trajectory.
#4 Please measure at least three cells for Figure 3. It appears that Figure 3b presents real-time single-cell fluorescence data for DNR uptake from only a single representative cell. For statistical robustness and to ensure the reliability of the conclusions, measurements from at least three independent cells at each time point should be included and quantitatively analyzed.
#5 Please give the fluorescent images of the cells for the generation of the Figure 4. The authors compared the fluorescence of two types of cells (148-WT and 10-CEM/VLB), it would be much more convincing if the authors provided the fluorescent cell images. As for Figs. 5-7, it is also recommended to add some experimental or simulated images to match the data figure.
#6 Please well decorate the paper figures. The figures within the whole manuscript are not provided scientifically and clearly. For example, some texts are too large, while some are too tiny. Please refer to the paper from other researches to increase the figure quality.
#7 Please talk about the work efficiency of this microfluidic platform. To measure the cell fluorescence, it is necessary to subtract the background information. Besides, the platform seems to be capable of measuring one cell once. Please talk about whether the work efficiency is adequate or not. If not, please give corresponding solutions.
Comments on the Quality of English Languagegood
Author Response
see attached file
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for Authors1) The numbering of references is a bit odd. In the first paragraph, I encountered 1, 2, and then 23 and 24. Authors should fix this for smooth reading.
2) I would like to see a paragraph about microfluidics or its subtype, like droplet microfluidics, with an explanation of applications and basics, which is used frequently for single-cell analysis in cancer applications ( https://doi.org/10.1039/D2LC00435F ), single cell analysis (https://doi.org/10.1002/anie.201200460) ( http://www.nature.com/doifinder/10.1038/nprot.2013.046 ), drug-resistant bacterial infection diagnostics, etc.
3) I would like to see more explanation about the microfluidic chip in section 2.1. The explanation seemed a bit too little. Please give information about the initial cell concentration, pressure/flow rates used, and a bit more details about the fabrication process, dimensions, and number of trapping sites in the chip.
4) Authors should include fluorescence images in one of the figures, and more details about the imaging interval and systems used.
5) I could not find the details about how many cells were analysed in total.
Author Response
see attachment
Author Response File:
Author Response.pdf