Review Reports
- Yukun He 1,2,
- Hongbo Zhao 3 and
- Yueyang Peng 1,2
- et al.
Reviewer 1: Valeri Slavchev Reviewer 2: Farhan Mumtaz Reviewer 3: Andrey V. Ustinov
Round 1
Reviewer 1 Report
Comments and Suggestions for AuthorsThe manuscript presents the design and error analysis of an optical wavefront measurement system intended for large-aperture segmented mirrors during the coarse calibration phase after in-orbit deployment. The topic is timely and relevant, and the authors address an important challenge in space optical metrology by combining optical system design, photogrammetry, error modeling, and experimental validation. Overall, the work demonstrates technical depth and includes both theoretical analysis and prototype testing, which are clear strengths of the paper.
However, in its current form, the manuscript requires several important revisions to improve its clarity, completeness, and scientific rigor. The following comments are intended to help enhance the overall quality and readability of the paper.
- The caption and explanation of Figure 2 are too brief. The authors should expand the description and clearly explain what is shown in the figure, including the system configuration, key components, and their roles within the wavefront measurement process. A more detailed explanation would significantly improve the reader's understanding of the proposed system architecture.
- Figure 4 contains two different subfigures, but they are not clearly separated or labeled. It is recommended that the authors explicitly divide the figure into subfigures (a) and (b), refer to them consistently in the text, and provide a clear explanation of what each subfigure represents. In addition, the values and labels on the coordinate axes are very small and difficult to read, especially compared to the main text. The axis labels and tick values should be enlarged to improve readability.
- In Figure 4, a spatial frequency of 156.25 lp/mm (line pairs per millimeter) is shown, but this value is not discussed in the text. This is a critical parameter related to the imaging performance of the camera and the system's resolving capability. The authors should explain the significance of this spatial frequency and clarify why this specific camera was selected. Providing additional technical details about the camera (sensor characteristics, pixel size, ...) would strengthen the justification of the system design.
- For Figure 5, which presents the optomechanical structure with exterior and sectional views, it would be beneficial to include key dimensions, labels, and annotations. Without dimensional information or component identification, the figure provides limited insight into the mechanical design. Adding such details would make the figure more informative and meaningful.
- The resolution and overall quality of Figures 6 and 7 should be improved. The figures should be presented at a larger size with higher resolution to ensure that all details, curves, and labels are clearly visible.
- The abbreviation "FOV" is used in Figures 3 and 22 without being defined in the text. Although it can be assumed to stand for "field of view", it should be explicitly introduced and defined when first used, in accordance with standard scientific writing conventions.
- In Figure 7, the caption and description should be revised to explicitly state the temperature conditions under which the data were obtained. It is currently unclear whether the presented results correspond to a reference temperature ( 24 °C) or another operating condition. This information is important for interpreting the thermal performance of the system.
- The conclusion section should be expanded to more clearly articulate why the proposed design and measurement method are advantageous compared to existing approaches. The authors should explicitly discuss:
- The main advantages of their system and methodology.
- The operational and measurement boundary conditions.
- The performance of the camera and system under low-illumination conditions and how such conditions affect measurement accuracy.
In addition, the authors are encouraged to include a broader discussion of related work by other research groups in this field. A more comprehensive comparison with existing methods would help clarify the specific contributions and advancements offered by the present study and would strengthen the literature review.
Author Response
Comments 1:The caption and explanation of Figure 2 are too brief. The authors should expand the description and clearly explain what is shown in the figure, including the system configuration, key components, and their roles within the wavefront measurement process. A more detailed explanation would significantly improve the reader's understanding of the proposed system architecture.
Response 1:Figure 2a-b has been revised to include the reference coordinate system of the folding mechanism, along with key steps in wavefront measurement such as triangulation principles, coordinate transformation, and wavefront fitting. Figure 2b briefly outlines the position of coordinate transformation and wavefront fitting within the wavefront measurement process. Detailed implementation methods are elaborated in the sections “Common Reference Transformation of Target” and “Wavefront Fitting.”
Comments 2:Figure 4 contains two different subfigures, but they are not clearly separated or labeled. It is recommended that the authors explicitly divide the figure into subfigures (a) and (b), refer to them consistently in the text, and provide a clear explanation of what each subfigure represents. In addition, the values and labels on the coordinate axes are very small and difficult to read, especially compared to the main text. The axis labels and tick values should be enlarged to improve readability.
Response 2:Figure 4(a) and (b) have been explained in greater detail, and the axis labels on the MTF curve plots have been optimized to enhance the readability of the images.
Comments 3:In Figure 4, a spatial frequency of 156.25 lp/mm (line pairs per millimeter) is shown, but this value is not discussed in the text. This is a critical parameter related to the imaging performance of the camera and the system's resolving capability. The authors should explain the significance of this spatial frequency and clarify why this specific camera was selected. Providing additional technical details about the camera (sensor characteristics, pixel size, ...) would strengthen the justification of the system design.
Response 3:In Figure 4(b), the value of 156.25 Lp/mm depends on the detector's pixel size, and the relevant calculation process is described in the annotation of Figure 4(b).
Comments 4:For Figure 5, which presents the optomechanical structure with exterior and sectional views, it would be beneficial to include key dimensions, labels, and annotations. Without dimensional information or component identification, the figure provides limited insight into the mechanical design. Adding such details would make the figure more informative and meaningful.
Response 4:In Figure 5(a), the outer envelope dimensions of the measurement camera have been added and annotated. Lenses, lens mount, retaining rings, and detector assembly have been labeled in Figure 5(b).
Comments 5:The resolution and overall quality of Figures 6 and 7 should be improved. The figures should be presented at a larger size with higher resolution to ensure that all details, curves, and labels are clearly visible.
Response 5:The clarity of the label values in Figures 6 and 7 has been optimized to improve the readability of the images.
Comments 6:The abbreviation "FOV" is used in Figures 3 and 22 without being defined in the text. Although it can be assumed to stand for "field of view", it should be explicitly introduced and defined when first used, in accordance with standard scientific writing conventions.
Response 6:Page 2, line 36 explains FOV.
Comments 7:In Figure 7, the caption and description should be revised to explicitly state the temperature conditions under which the data were obtained. It is currently unclear whether the presented results correspond to a reference temperature ( 24 °C) or another operating condition. This information is important for interpreting the thermal performance of the system.
Response 7:The reference temperature of 20°C for the finite element simulation was described in the annotations of Figure 7. The actual simulation temperature was 24°C, simulating a thermal load with a 4°C temperature rise.
Comments 8:The conclusion section should be expanded to more clearly articulate why the proposed design and measurement method are advantageous compared to existing approaches. The authors should explicitly discuss:
- The main advantages of their system and methodology.
- The operational and measurement boundary conditions.
- The performance of the camera and system under low-illumination conditions and how such conditions affect measurement accuracy.
Response 8:A discussion section has been added, outlining the primary advantages of this proposal in terms of in-orbit environmental adaptability and measurement range. The discussion elaborates on the operational environment and conditions for the proposed measurement system. Furthermore, the active target designed in this study provides illumination in low-light conditions, ensuring camera imaging and mitigating the impact of orbital shadow zones on measurements.
Comments 9:In addition, the authors are encouraged to include a broader discussion of related work by other research groups in this field. A more comprehensive comparison with existing methods would help clarify the specific contributions and advancements offered by the present study and would strengthen the literature review.
Response 9:Table 16 has been added to the discussion, comparing key technical indicators between existing solutions and the proposed approach to further illustrate the advantages and innovations of the proposed solution.
Author Response File:
Author Response.pdf
Reviewer 2 Report
Comments and Suggestions for AuthorsThe authors report an interesting way to design a system for measuring the shape of large, segmented mirrors, which is crucial for their setup and adjustment in space. The paper, titled "Design and Error Analysis of an Optical Measurement System for the Wavefront of Large-Aperture Segmented Mirror," is noteworthy. However, several aspects of the methods used, the presentation of results, and the discussion need significant improvement to meet the standards of a technical publication. A major revision is recommended, and the specific points that require attention are as follows:
- The abstract must clearly state the new contributions of this work compared to existing methods, especially regarding the specific challenges of large segmented mirrors in a space environment. The current abstract is quite descriptive but lacks a strong statement of innovation.
- In the Introduction, while the discussion of existing technologies (JWST, ELT, DFS) is good, it requires a more direct comparison of their limitations (especially regarding large measurement range and accuracy) that this proposed system aims to overcome.
- The description of target distribution in Figure 3(a) mentions "8 reference targets with all four cameras" as the measurement baseline. These reference targets should be explicitly highlighted in the diagram, perhaps with a distinct color or shape, to make their role clearer.
- Table 1, "Key Parameters of the Measurement System," lists "Deviation RMS < 0.1 mm, PV < 0.45 mm" for wavefront measurement accuracy. An explicit statement is needed explaining why these values meet the requirements for coarse calibration, perhaps by referencing relevant sections or calculations.
- In Figure 4, the MTF curve shows "156.25 Lp/mm" as the spatial frequency limit. A discussion is necessary concerning how this relates to the camera's resolution and the ability to accurately measure target positions, especially given the pixel size mentioned in Table 5.
- Figure 5 (Optomechanical Structure) requires more specific annotations in the sectional view (b) to highlight key components like the lenses, lens mount, retaining rings, and detector assembly, as discussed in the text.
- The results of finite element analysis in Figure 6 and Figure 7 show "Contour Plot Displacement(Mag)" and "Surface figure." Units for the displacement magnitude (e.g., mm or µm) must be included, and a more explicit scale provided for the surface figure, especially its relation to the wavefront error criteria.
- Table 4, "Optomechanical Integration Analysis Results," provides PV and RMS values in nanometers. A brief explanation of the significance of these values in relation to the overall system performance and requirements for the optical components is necessary.
- Figure 21, "Target Position Measurement Error," shows curves for Z-axis and Y-axis errors. A more detailed explanation of the implications of these error magnitudes at different object distances for the overall wavefront fitting accuracy would strengthen the discussion.
- The conclusion states that the Chebyshev polynomial achieved maximum wavefront fitting deviations of 0.397 mm (PV) and 0.073 mm (RMS), meeting coarse calibration requirements. An explicit link between these values and the initial measurement accuracy requirements stated in Table 1 (Deviation RMS < 0.1 mm, PV < 0.45 mm) is required to clearly demonstrate that the system design and fitting algorithm meet the specifications.
Author Response
Comments 1:The abstract must clearly state the new contributions of this work compared to existing methods, especially regarding the specific challenges of large segmented mirrors in a space environment. The current abstract is quite descriptive but lacks a strong statement of innovation.
Response 1:Page 1, line 25: The abstract outlines the key advantages of this work compared to other systems. Page 3, line 95: The introduction details the main contributions of this work.
Comments 2:In the Introduction, while the discussion of existing technologies (JWST, ELT, DFS) is good, it requires a more direct comparison of their limitations (especially regarding large measurement range and accuracy) that this proposed system aims to overcome.
Response 2:Table 16 has been added to the discussion, comparing key technical indicators between existing solutions and the proposed approach to further illustrate the advantages and innovations of the proposed solution.
Comments 3:The description of target distribution in Figure 3(a) mentions "8 reference targets with all four cameras" as the measurement baseline. These reference targets should be explicitly highlighted in the diagram, perhaps with a distinct color or shape, to make their role clearer.
Response 3:The reference targets in Figure 3(a) have been marked with triangles.
Comments 4:Table 1, "Key Parameters of the Measurement System," lists "Deviation RMS < 0.1 mm, PV < 0.45 mm" for wavefront measurement accuracy. An explicit statement is needed explaining why these values meet the requirements for coarse calibration, perhaps by referencing relevant sections or calculations.
Response 4:If the deviation between the measured wavefront and the actual wavefront is too large after the coarse calibration stage, the fine calibration stage cannot proceed. Therefore, during the coarse calibration stage, the wavefront must be calibrated within the measurement range of the wavefront sensor. According to existing public data, the maximum measurement range of the sensor in the fine calibration stage is 0.5 mm. Thus, the PV measurement accuracy of the measurement system in this paper must be less than 0.5 mm. Considering measurement margin, PV < 0.45 mm. Relevant discussions and reference opinions are mentioned in the article. The RMS < 0.1 mm specification is determined based on engineering experience. For optical surfaces, PV is typically 3 to 5 times the RMS value. This paper adopts a factor of 4.5, resulting in an RMS measurement accuracy better than 0.1 mm. Relevant discussions have been supplemented in the text. Page6,Line172.
Comments 5:In Figure 4, the MTF curve shows "156.25 Lp/mm" as the spatial frequency limit. A discussion is necessary concerning how this relates to the camera's resolution and the ability to accurately measure target positions, especially given the pixel size mentioned in Table 5.
Response 5:In Figure 4(b), the value of 156.25 Lp/mm depends on the detector's pixel size. The relevant calculation process has been described in the annotation for Figure 4(b).
Comments 6:Figure 5 (Optomechanical Structure) requires more specific annotations in the sectional view (b) to highlight key components like the lenses, lens mount, retaining rings, and detector assembly, as discussed in the text.
Response 6:Lenses, lens mount, retaining rings, and detector assembly are labeled in Figure 5(b).
Comments 7:The results of finite element analysis in Figure 6 and Figure 7 show "Contour Plot Displacement (Mag)" and "Surface figure." Units for the displacement magnitude (e.g., mm or µm) must be included, and a more explicit scale provided for the surface figure, especially its relation to the wavefront error criteria.
Response 7:Figure 6 and Figure 7 have already described the units for “Contour Plot Displacement (Mag)” and “Surface Figure.”
Comments 8:Table 4, "Optomechanical Integration Analysis Results," provides PV and RMS values in nanometers. A brief explanation of the significance of these values in relation to the overall system performance and requirements for the optical components is necessary.
Response 8:Page 9, Line 239 explains the importance of PV and RMS on optical element surfaces for camera imaging quality and specifies the relevant requirements.
Comments 9:Figure 21, "Target Position Measurement Error," shows curves for Z-axis and Y-axis errors. A more detailed explanation of the implications of these error magnitudes at different object distances for the overall wavefront fitting accuracy would strengthen the discussion.
Response 9:In the deviation analysis, Table 15 has been added. The error input for Table 15 is the camera measurement error corresponding to the measured object distance, while the error input for Table 14 is the maximum measurement error of the measuring camera. Since the error input value for Table 14 is larger, the error analysis results for Table 15 are smaller than those for Table 14.
Comments 10:The conclusion states that the Chebyshev polynomial achieved maximum wavefront fitting deviations of 0.397 mm (PV) and 0.073 mm (RMS), meeting coarse calibration requirements. An explicit link between these values and the initial measurement accuracy requirements stated in Table 1 (Deviation RMS < 0.1 mm, PV < 0.45 mm) is required to clearly demonstrate that the system design and fitting algorithm meet the specifications.
Response 10:Page 29, line 696, explains the relationship between 0.397 mm (PV) and 0.073 mm (RMS) and the measurement accuracy requirements in Table 2 (formerly Table 1).
Author Response File:
Author Response.pdf
Reviewer 3 Report
Comments and Suggestions for AuthorsNotes to the manuscript
“Design and Error Analysis of an Optical Measurement System for the Wavefront of Large-Aperture Segmented Mirror”
The authors present a measurement system based on an optical camera and targets to increase an accuracy of the wavefront measurement for large-aperture segmented mirrors after in-orbit deployment. This system utilizes photogrammetry principles to measure target positions, fit the wavefront of the segmented mirror, and form a control with the calibration mechanism. The measurement camera features a 16°×12° rectangular field of view with a 100 mm focal length and it achieved modulation transfer function greater than 0.11. A quantitative analysis of error sources and their impact on target position measurement accuracy was conducted. Finite element simulation and Monte Carlo methods analyzed wavefront fitting accuracy under different operating conditions. Results show that the wavefront measurement deviation meets the accuracy requirements for the coarse calibration phase. It is also shown that in this problem, the use of Chebyshev polynomials for wavefront fitting provides higher accuracy than Zernike polynomials.
The manuscript is well written, основная часть замечаний – the main part of the comments consist of correcting typos and making changes to the text.
Notes.
In the Introduction, it is advisable to mention a review describing the correction of optical aberrations: [Optical wavefront aberration: detection, recognition, and compensation techniques - a comprehensive review, Optics & Laser Technology 191, 113342-(22p) (2025); https://doi.org/10.1016/j.optlastec.2025.113342].
Page 4, Figure 2(b). ”u” replace by ”v”.
Page 8, Line 185. ”the intallation plate” replace by ”the installation plate”.
Page 11, Line 276. ”the intallnation platform” replace by ”the installation platform”.
Page 13, Eq. (1). Add a + sign to the exponent.
Page 16, Table 8. ”4x2-3x” replace by ” 4x3-3x ” in row 7.
Page 19, Eq. (3). It is advisable to add the final result –(epL/f)dy to the formula. Similarly in formulas (4) and (5).
Page 19, Line 443. ”is 0.114 mm.” replace by ”is 0.152 mm.”.
Page 23. Caption of Figure 23 is identical to caption of Figure 22.
Page 23, Line 519. There is a phrase “was calculated using the following formula”, but the formula is absent.
Page 26, Table 13. Is it possible to explain why the greatest deviations are observed at temperatures in the middle part of the range?
Pages 27-28. Check the list of authors in sources [3], [13], [20], [23].
Author Response
Comments 1:In the Introduction, it is advisable to mention a review describing the correction of optical aberrations: [Optical wavefront aberration: detection, recognition, and compensation techniques - a comprehensive review, Optics & Laser Technology 191, 113342-(22p) (2025); https://doi.org/10.1016/j.optlastec.2025.113342].
Response 1:This literature reviews the current state of wavefront measurement research, future challenges, and development directions, aligning closely with the research focus of this paper. It also provides guidance for the author's further investigation into wavefront measurement techniques. This paper has already cited this literature as Ref[4].
Comments 2:Page 4, Figure 2(b). ”u” replace by ”v”.
Response 2:u has been modified to [v,u], and Z has been simultaneously changed to [Z,X] to further clarify the relationship. Additionally, the wavefront fitting step has been added to Figure 2(b) to enhance the clarity of the principle explanation.
Comments 3:Page 8, Line 185. ”the intallation plate” replace by ”the installation plate”.
Response 3:Page 9, line 218, has been corrected for spelling errors.
Comments 4:Page 11, Line 276. ”the intallnation platform” replace by ”the installation platform”.
Response 4:Page12,line313, has been corrected for spelling errors.
Comments 5:Page 13, Eq. (1). Add a + sign to the exponent.
Response 5:The “+” sign has been added to the exponential part of Eq. (1).
Comments 6:Page 16, Table 8. ”4x2-3x” replace by ” 4x3-3x ” in row 7.
Response 6:Table 9 (formerly Table 8), the 7th row has been modified to reflect the updated index values.
Comments 7:Page 19, Eq. (3). It is advisable to add the final result –(epL/f)dy to the formula. Similarly in formulas (4) and (5).
Response 7:Equations (3), (4), and (5) have been revised to refine the final results of the formula.
Comments 8:Page 19, Line 443. ”is 0.114 mm.” replace by ”is 0.152 mm.”.
Response 8:Page20,line480,The numbers have been modified.
Comments 9:Page 23. Caption of Figure 23 is identical to caption of Figure 22.
Response 9:Page24,line555,The title of Figure 23 has been revised.
Comments 10:Page 23, Line 519. There is a phrase “was calculated using the following formula”, but the formula is absent.
Response 10:The MTF calculation formula, Eq. (9), has been added.
Comments 11:Page 26, Table 13. Is it possible to explain why the greatest deviations are observed at temperatures in the middle part of the range?
Response 11:Table 14 (formerly Table 13) shows the wavefront fitting deviation used to evaluate the measurement accuracy of the system. This deviation depends on the measurement errors introduced during Monte Carlo simulations and has no direct correlation with temperature. The wavefront error of the segment mirror is temperature-dependent, and its PV values under different temperature conditions are provided in Table 1. It is important to distinguish between the PV value of the wavefront error of the segment mirror itself and the PV value of the wavefront fitting deviation. The former refers to the wavefront error of the segment mirror itself under the influence of temperature and the folding mechanism, while the latter refers to the deviation when calculating and fitting the wavefront of the segment mirror using the measurement system proposed in this paper. The distinction between wavefront error and wavefront fitting deviation is described in Figure 24.
Comments 12:Pages 27-28. Check the list of authors in sources [3], [13], [20], [23].
Response 12:Pages 30-31: Formatting has been revised for [3], [16], [25], and [28].
Author Response File:
Author Response.pdf
Round 2
Reviewer 1 Report
Comments and Suggestions for AuthorsThe authors have carefully addressed the majority of the reviewer comments from the previous round. The manuscript has been significantly improved in terms of clarity, structure, and technical completeness. The additional explanations and expanded analyzes have strengthened the overall quality of the work, and the paper now presents a clearer and more coherent description of the proposed measurement system and its validation.
I appreciate the authors' efforts in revising the manuscript. However, I still have several minor comments that, if addressed, would further improve the quality and readability of the paper:
- The description of the target design requires additional detail. While the figure indicates that the pinhole diameter is Φ0.05 mm, the spacing between adjacent pinholes is not specified. Since this parameter directly affects photogrammetric accuracy and target recognition performance, the distance between pinholes should be clearly stated either in the figure or in the accompanying description.
- It is unclear why Figure 19 is included in the manuscript if it is not explicitly referenced in the main text. Please ensure that all figures are properly cited and discussed. If Figure 19 does not contribute directly to the analysis or discussion, the authors may consider removing it.
- Figures 11 and 19 contain an abbreviation (FIT) that appears to be important for understanding the presented results. However, this abbreviation is neither defined nor discussed anywhere in the manuscript. All abbreviations must be clearly defined at their first occurrence in the text.
- The axes in Figure 14 lack labels and units. Neither the coordinate axes nor their physical meaning are described in the figure caption. Proper axis labeling (including units, where applicable) is essential for clarity and reproducibility.
- In Figure 17 (“Wavefront after Chebyshev polynomial fitting: 3D View in Upper; 2D View in Lower”), the two subfigures should be explicitly labeled ((a) and (b)). These labels should also be referenced in the caption to improve clarity and facilitate discussion in the text.
In conclusion, the manuscript has improved substantially and is close to being suitable for publication. Addressing the minor points listed above will further enhance its technical clarity and presentation quality
Author Response
Comments 1:The description of the target design requires additional detail. While the figure indicates that the pinhole diameter is Φ0.05 mm, the spacing between adjacent pinholes is not specified. Since this parameter directly affects photogrammetric accuracy and target recognition performance, the distance between pinholes should be clearly stated either in the figure or in the accompanying description.
Response 1:The spacing of adjacent pinholes has been added in Figure 10: 0.78mm.
Comments 2:It is unclear why Figure 19 is included in the manuscript if it is not explicitly referenced in the main text. Please ensure that all figures are properly cited and discussed. If Figure 19 does not contribute directly to the analysis or discussion, the authors may consider removing it.
Response 2:Figure 19 illustrates the impact of image noise on the accuracy of centroid estimation. A citation for Figure 19 has been added to the text.
Comments 3:Figures 11 and 19 contain an abbreviation (FIT) that appears to be important for understanding the presented results. However, this abbreviation is neither defined nor discussed anywhere in the manuscript. All abbreviations must be clearly defined at their first occurrence in the text.
Response 3:“FIT” in Figures 11 and 19 refers to “Circle fit,” and the corresponding descriptions have been refined in Figures 11 and 19.
Comments 4:The axes in Figure 14 lack labels and units. Neither the coordinate axes nor their physical meaning are described in the figure caption. Proper axis labeling (including units, where applicable) is essential for clarity and reproducibility.
Response 4:Figure 14 adds axis labels and corresponding physical units.
Comments 5:In Figure 17 (“Wavefront after Chebyshev polynomial fitting: 3D View in Upper; 2D View in Lower”), the two subfigures should be explicitly labeled ((a) and (b)). These labels should also be referenced in the caption to improve clarity and facilitate discussion in the text.
Response 5:The two subfigures in Figure 17 have been clearly labeled as (a) and (b). They are referenced in the main text.
Reviewer 2 Report
Comments and Suggestions for AuthorsThe authors addressed most of the concerns.
Author Response
comment:The authors addressed most of the concerns.