Skip to Content
You are currently on the new version of our website. Access the old version .
SensorsSensors
  • Article
  • Open Access

19 December 2025

20 Pages

From Laboratory to Field: Concurrent Validity of Kinovea’s Linear Kinematics Tracking Tool for Semi-Automated Countermovement Jump Analysis

,
,
,
,
,
and
1
Faculty of Kinesiology, University of Osijek, 31000 Osijek, Croatia
2
Faculty of Sport and Physical Education, University of Belgrade, Blagoja Parovica 156, 11000 Belgrade, Serbia
3
Faculty of Medicine, University of Osijek, 31000 Osijek, Croatia
4
Faculty of Dental Medicine and Health, University of Osijek, 31000 Osijek, Croatia

Abstract

Affordable high-frame-rate cameras and open-source software, such as Kinovea (ver. 2025.1.0), have expanded the potential for conducting kinematic assessments outside laboratory settings. This study examined the reliability and validity of Kinovea’s semi-automated linear kinematics tracking tool by comparing its outputs with those from a 3D marker-based motion capture system (Qualisys). Ten recreationally active male basketball players (x̄ ± SD: age 23.7 ± 1.7 years; height 183 ± 5 cm; body mass 76.8 ± 9.8 kg) performed three CMJ trials, simultaneously recorded using both systems. Reflective markers placed on the shoulder, hip, and knee were tracked in Kinovea by two raters with different levels of experience to extract core CMJ variables (total take-off time and maximum vertical displacement) and complementary variables (eccentric and propulsion duration, and minimum vertical displacement). Inter-rater reliability and concurrent validity were evaluated using intraclass correlation coefficients (ICCs), coefficients of variation (CV%), standard error of measurement (SEM), and Bland–Altman analysis. Results showed excellent inter-rater reliability (ICC = 0.73–0.99) across all markers, with the hip and knee demonstrating the highest consistency. Strong validity relative to Qualisys was observed for both raters (ICC = 0.68–0.99; r > 0.80), with small systematic biases primarily in temporal variables. Collectively, these findings demonstrate that Kinovea’s semi-automated 2D analysis yields reliable and valid CMJ measurements comparable to 3D motion capture, even for less experienced users. As a free and easily deployable tool, it offers a widely accessible alternative for field-based performance monitoring and applied biomechanics research where laboratory-grade equipment is not available.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.