Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (60)

Search Parameters:
Keywords = unreinforced masonry (URM)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
31 pages, 15889 KB  
Article
Comparison of Different Seismic Fragility Models for the Prediction of the 2012 Emilia Damage Scenario
by Chiara Monteferrante, Vitor Silva and Nicola Buratti
Buildings 2026, 16(16), 3236; https://doi.org/10.3390/buildings16163236 - 14 Aug 2026
Viewed by 194
Abstract
This study addresses the seismic vulnerability of unreinforced masonry (URM) buildings affected by the 2012 Emilia earthquake sequence through a scenario-based damage assessment. The OpenQuake engine is employed to simulate damage scenarios by integrating detailed exposure data, ground-motion fields derived from INGV and [...] Read more.
This study addresses the seismic vulnerability of unreinforced masonry (URM) buildings affected by the 2012 Emilia earthquake sequence through a scenario-based damage assessment. The OpenQuake engine is employed to simulate damage scenarios by integrating detailed exposure data, ground-motion fields derived from INGV and UNIBO shakemaps, and a selection of fragility models developed using different methodological frameworks. Particular attention is given to the critical comparison of analytical, empirical, and hybrid models, with reference to their underlying assumptions, treatment of seismic input, and compatibility with available exposure and damage data. The results demonstrate that fragility-model selection, ground-motion representation, and regional construction typologies substantially influence scenario-based damage estimates. By fostering a more informed and critical use of fragility functions, this work provides a methodological framework for their application in damage scenario simulations and risk-informed decision-making, thereby supporting the refinement of vulnerability models and the development of more effective strategies for risk mitigation and emergency planning. Full article
(This article belongs to the Special Issue Seismic Protection and Preparedness of the Built Environment)
Show Figures

Figure 1

26 pages, 9769 KB  
Article
Numerical Investigation of Masonry Walls Using Mega-Interlocking Concrete Blocks
by Antoon Labib, Bowen Zeng, Carlos Cruz-Noguez and Yong Li
Modelling 2026, 7(2), 66; https://doi.org/10.3390/modelling7020066 - 29 Mar 2026
Cited by 2 | Viewed by 1305
Abstract
Conventional concrete masonry construction consists of an assemblage of concrete blocks, mortar, grout, and steel reinforcement. While effective, this constructive method is constrained by its low productivity. In recent decades, advances in construction and manufacturing technologies now allow for the production of larger [...] Read more.
Conventional concrete masonry construction consists of an assemblage of concrete blocks, mortar, grout, and steel reinforcement. While effective, this constructive method is constrained by its low productivity. In recent decades, advances in construction and manufacturing technologies now allow for the production of larger and more complex block typologies, enabling designers to reassess conventional designs to optimize structural performance and construction efficiency. As such, this study introduces the “mega-interlocking block”, a novel block that integrates the benefits of mega blocks (i.e., blocks with larger sizes) with a newly designed interlocking mechanism to enhance structural performance and expedite the construction of masonry walls in work sites where forklifts, scissor lifts and other smaller crane equipment are available. A numerical study was conducted to evaluate the in-plane (IP) and out-of-plane (OOP) behaviors of masonry walls constructed with mega-interlocking blocks, including both unreinforced masonry (URM) and reinforced masonry (RM) configurations, compared to standard block walls. A simplified micro-modeling approach was utilized to account for various possible failure modes associated with masonry structures. Results indicate that mega-interlocking blocks significantly improve wall stiffness and load-bearing capacity under IP loading, both with and without mortar, outperforming standard block walls. Under OOP loading, interlocking blocks provide moderate performance gains when mortar is present, though their effectiveness diminishes in mortarless configurations. For URM walls under IP loading, the implementation of mega-interlocking blocks yielded substantial improvements in stiffness and capacity, with the most notable benefits observed in walls with larger aspect ratios. Although the relative advantages in RM walls were less pronounced due to the homogenizing effects of grout and reinforcement, mega-interlocking blocks still demonstrated robust structural performance, making them a promising alternative to standard masonry units. Full article
(This article belongs to the Section Modelling in Engineering Structures)
Show Figures

Figure 1

27 pages, 5442 KB  
Article
Seismic Vulnerability Assessment and Upgrade Strategies of Unreinforced Masonry Buildings—Case Studies from Croatia
by Laurie Ducom, Chaimaa Jaafari and Mislav Stepinac
Buildings 2026, 16(6), 1238; https://doi.org/10.3390/buildings16061238 - 20 Mar 2026
Viewed by 731
Abstract
Earthquakes are rare and infrequent natural phenomena with considerable consequences for the urban environment, human life and society. Croatia is a country highly exposed to seismic risks due to its geographical location and its large stock of unreinforced masonry buildings (URM). This article [...] Read more.
Earthquakes are rare and infrequent natural phenomena with considerable consequences for the urban environment, human life and society. Croatia is a country highly exposed to seismic risks due to its geographical location and its large stock of unreinforced masonry buildings (URM). This article proposes an assessment of their vulnerability by combining a macroseismic approach, allowing for a comprehensive analysis of a group of buildings, with detailed numerical modelling of a building in Zagreb using 3Muri 12.2 software. Three reinforcement techniques are compared in terms of their structural performance, cost, carbon footprint and compatibility with the built heritage. The study shows that each method has advantages and limitations: shotcrete is low-cost but has a high carbon impact and can be too invasive for heritage buildings; FRP offers the best structural performance but remains very expensive, while FRCM appears to be a balanced compromise, combining performance, durability and compliance with architectural conservation constraints. This article highlights the importance of adapting the approach to each situation and combining reliable assessment with appropriate reinforcement solutions. It also invites reflection on the possibility of linking seismic interventions and energy renovations to improve safety, economy, sustainability and living comfort. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

50 pages, 25225 KB  
Article
Mitigating Damage in Laterally Supported URM Walls Under Severe Catastrophic Blast Using UHPC and UHPFRC Coatings with and Without Embedded Steel-Welded Wire Mesh
by S. M. Anas, Rayeh Nasr Al-Dala’ien, Mohammed Benzerara and Mohammed Jalal Al-Ezzi
Appl. Mech. 2026, 7(1), 23; https://doi.org/10.3390/applmech7010023 - 11 Mar 2026
Cited by 3 | Viewed by 1453
Abstract
In many densely populated towns and semi-urban areas, masonry buildings often stand close to busy roads, exposing them to blasts from improvised explosives or other localized sources. Such structures are rarely designed to resist sudden explosive forces, making severe damage or even progressive [...] Read more.
In many densely populated towns and semi-urban areas, masonry buildings often stand close to busy roads, exposing them to blasts from improvised explosives or other localized sources. Such structures are rarely designed to resist sudden explosive forces, making severe damage or even progressive collapse likely. Even moderate-intensity blasts can weaken walls, endanger occupants, and cause significant property loss. Unlike reinforced concrete, masonry is highly susceptible to explosive impact. Therefore, understanding how these buildings behave under blast loads and developing affordable protection methods is crucial. Low-rise unreinforced masonry (URM) structures, usually up to about 13 m in height (roughly 2–4 stories), common in villages, semi-urban regions, and conflict-prone zones, are particularly at risk. In many areas, these poorly constructed buildings lack proper engineering design and are therefore highly vulnerable to blast damage. Non-load-bearing internal dividers and perimeter enclosures are especially prone to lateral displacement, which can initiate instability and, in severe cases, lead to overall structural failure. This research focuses on reducing catastrophic damage in URM walls when exposed to close-proximity blast forces using concrete-based protective coatings, both with and without embedded steel-welded wire mesh. The study references a previously tested laterally supported clay brick wall built with cement–sand mortar as the baseline model, with its behavior validated against experimental findings from existing literature. Two blast cases were considered corresponding to scaled stand-off distances of 2.19 m/kg1/3 and 1.83 m/kg1/3, representing moderate flexural-shear cracking and full structural failure, respectively. To replicate the observed behavior, a comprehensive 3D numerical simulation was developed using the ABAQUS/Explicit 2020 solver. The model’s predictions were benchmarked and verified through comparison with reported test data. While both blast intensities were used to confirm computational accuracy, the effectiveness of UHPC and UHPFRC protective coatings with and without embedded wire mesh was specifically evaluated under the more severe collapse scenario (Z = 1.83 m/kg1/3). Results indicated that at a scaled distance of 1.83 m/kg1/3, the uncoated URM wall could not withstand the blast because of poor tensile and bending capacity. In contrast, the UHPC- and UHPFRC-coatings provided improved confinement and better stress distribution. When welded wire mesh was embedded, crack control improved further, the interface bond strengthened, and a larger portion of blast energy was absorbed and dissipated. Full article
Show Figures

Figure 1

7 pages, 1892 KB  
Proceeding Paper
Spectrum-Based Assessment of Damaged Low-Rise Masonry Building
by Marjo Hysenlliu, Huseyin Bilgin and Altin Bidaj
Eng. Proc. 2026, 125(1), 8; https://doi.org/10.3390/engproc2026125008 - 26 Jan 2026
Viewed by 434
Abstract
Seismic performance evaluation of existing buildings is essential for defining effective mitigation strategies in earthquake-prone regions. This study investigates the seismic performance of low-rise unreinforced masonry (URM) residential buildings located in several cities in the Albanian territory. Material properties were obtained from experimental [...] Read more.
Seismic performance evaluation of existing buildings is essential for defining effective mitigation strategies in earthquake-prone regions. This study investigates the seismic performance of low-rise unreinforced masonry (URM) residential buildings located in several cities in the Albanian territory. Material properties were obtained from experimental tests conducted on representative samples and subsequently adopted in the development of analytical models. Three-dimensional finite element models were generated based on the collected geometric data and experimentally determined material characteristics. Nonlinear static (pushover) analyses were carried out to assess the seismic capacity and identify the potential failure mechanisms of the buildings. The numerical results showed significant variation in performance depending on the building typology, with some cases reaching the near-collapse limit state under design-level earthquakes. The capacity curves and performance points obtained from the models demonstrate the pronounced influence of construction techniques, boundary conditions, and material properties on the seismic response. The results indicated that URM residential buildings exhibit distinctive seismic performance characteristics influenced by their construction techniques and material properties. Based on the findings, recommendations for retrofit strategies are proposed to enhance the seismic resilience of such structures. Full article
Show Figures

Figure 1

38 pages, 9151 KB  
Article
Experimental and Numerical Investigation of Historic Brickwork Masonry with Weak and Degraded Joints: Failure Mechanisms Under Compression and Shear
by Erica Magagnini, Vanni Nicoletti and Fabrizio Gara
Buildings 2025, 15(21), 3993; https://doi.org/10.3390/buildings15213993 - 5 Nov 2025
Cited by 1 | Viewed by 1562
Abstract
The failure behaviour of historic unreinforced masonry (URM) structures is strongly influenced by the properties of bricks and mortar. Over time, degradation processes compromise these materials, with significant effect on structural response and safety. Nevertheless, deterioration effects on the nonlinear behaviour of masonry [...] Read more.
The failure behaviour of historic unreinforced masonry (URM) structures is strongly influenced by the properties of bricks and mortar. Over time, degradation processes compromise these materials, with significant effect on structural response and safety. Nevertheless, deterioration effects on the nonlinear behaviour of masonry have been only marginally investigated. This study investigates the mechanical behaviour and failure mechanisms of historic brick masonry with weak and irregular mortar joints, representative of Mediterranean traditional constructions. An extensive experimental programme was conducted on mortars, historic clay bricks, prisms, wallets, and triplet specimens, complemented by in-situ flat jack tests. Results confirm the critical role of mortar quality and joint irregularities in reducing compressive and shear strength and in influencing deformation capacity of historic masonry. The experimental findings served as a basis for the calibration of a Finite Element Model (FEM), subsequently employed to gain deeper insight into the governing failure mechanisms in a real study case. A critical discussion of compression and shear failure criteria is presented, focusing on historic masonry. Experimental and analytical comparisons show major discrepancies in classical criteria, especially with degraded mortars. The study shows that in historic masonry with weak joints, failure is often governed by compression rather than shear. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

22 pages, 3172 KB  
Article
On the Out-of-Plane Strength of Masonry Infills Encased in RC Frames
by Lampros Kouzelis and Marina L. Moretti
Appl. Sci. 2025, 15(19), 10382; https://doi.org/10.3390/app151910382 - 24 Sep 2025
Cited by 2 | Viewed by 1389
Abstract
With reference to the widespread out-of-plane (OOP) failures of infill walls in reinforced concrete (RC) buildings during the 6 February 2023 earthquakes in Kahramanmaraş, Turkey, this paper investigates the OOP strength of unreinforced masonry (URM) infills without openings, enclosed in RC frames, while [...] Read more.
With reference to the widespread out-of-plane (OOP) failures of infill walls in reinforced concrete (RC) buildings during the 6 February 2023 earthquakes in Kahramanmaraş, Turkey, this paper investigates the OOP strength of unreinforced masonry (URM) infills without openings, enclosed in RC frames, while also considering the effect of prior in-plane (IP) loading. A comprehensive database has been compiled, including all available tests on infills subjected to OOP loading and sequential IP–OOP loading, as well as those on infills with gaps between the RC frame and the masonry panel. This study evaluates the effectiveness of established design models at predicting the OOP strength of infills in RC frames and proposes refinements to improve the predictive accuracy. For the OOP strength, two arch-based models are applied, and the impact of prior IP loading is addressed through a reduction factor, R. Based on test observations showing that prior IP loading disproportionately reduces the OOP strength in vulnerable infills, an improved R-factor is introduced, providing better alignment with experimental results than four existing design formulas. The influence of gaps between the infill and RC frame on the OOP behavior is also examined. The findings reveal inconsistencies and reduced reliability among the available design models, highlighting the need for further research on this critical topic. Full article
(This article belongs to the Special Issue Seismic Response and Safety Assessment of Building Structures)
Show Figures

Figure 1

55 pages, 3852 KB  
Review
Review of the Influence of the Interaction Between In-Plane and Out-of-Plane Behaviors on the Seismic Response of Non-Framed Unreinforced Masonry Walls
by Amirhossein Ghezelbash, Jan G. Rots and Francesco Messali
Buildings 2025, 15(16), 2874; https://doi.org/10.3390/buildings15162874 - 14 Aug 2025
Cited by 6 | Viewed by 1845
Abstract
This study reviews existing research on the effects of the interaction between in-plane (IP) and out-of-plane (OOP) behaviors on the seismic response of non-framed unreinforced masonry (URM) structures. During earthquakes, masonry buildings exhibit complex behaviors. First, walls may experience simultaneous IP and OOP [...] Read more.
This study reviews existing research on the effects of the interaction between in-plane (IP) and out-of-plane (OOP) behaviors on the seismic response of non-framed unreinforced masonry (URM) structures. During earthquakes, masonry buildings exhibit complex behaviors. First, walls may experience simultaneous IP and OOP actions, or pre-existing IP and OOP damage, deformation, or loads that can alter their unidirectional IP or OOP seismic response. Second, the IP and OOP action of one wall can affect the behavior of its intersecting walls. However, the effects of these behaviors, referred to as “direct IP-OOP interactions” and “Flange effects”, respectively, are often disregarded in design and assessment provisions. To address this gap, this study explores findings from experimental and numerical research conducted at the wall level currently available in the literature, identifying the nature of these interaction effects and the key parameters that affect their extent. The available body of work includes only a few experimental studies on interaction effects, whereas numerical investigations are more extensive. However, most numerical studies focus on how OOP pre-damage/deformation influences the IP behaviors (OOP/IP interactions) and the role of flanges in IP response (F/IP interactions), leaving significant gaps in understanding the effects of IP pre-damage/deformation on the OOP response (IP/OOP interactions) and the OOP response in the presence of flanges (F/OOP interactions). Among the parameters studied, boundary conditions, wall height-to-length aspect ratio, and vertical overburden are found to have the most significant influence on interaction effects because of their relevance for the IP and OOP failure mechanisms. Other parameters, such as the restriction of top uplift, the presence of openings, or changes in slenderness ratio, are not comprehensively studied, and the available data are insufficient for definitive conclusions. Methodologies available in the literature for extrapolating the findings observed at the wall level to building-level analyses are reviewed. The current predictive equations primarily address the effects of OOP pre-load and Flange effects on IP response. Furthermore, only a few macro-element models are proposed for cost-effective, large-scale building simulations. To bridge these gaps, future research must expand experimental investigations, develop more comprehensive design and assessment equations, and refine numerical modeling techniques for building-level applications. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

34 pages, 19699 KB  
Article
Comprehensive Material Characterization and Seismic Performance Evaluation of a Traditional Masonry Residential Building with Reinforced Concrete Slabs
by Basak Boduroglu Yazici and Oguz Uzdil
Buildings 2025, 15(10), 1710; https://doi.org/10.3390/buildings15101710 - 18 May 2025
Cited by 4 | Viewed by 3291
Abstract
Reinforced concrete began replacing traditional masonry construction in the early 20th century, yet hybrid buildings combining unreinforced masonry (URM) walls with concrete slabs remain prevalent in Istanbul. Understanding their seismic behavior is critical for risk mitigation and heritage preservation. This study investigates a [...] Read more.
Reinforced concrete began replacing traditional masonry construction in the early 20th century, yet hybrid buildings combining unreinforced masonry (URM) walls with concrete slabs remain prevalent in Istanbul. Understanding their seismic behavior is critical for risk mitigation and heritage preservation. This study investigates a seven-story masonry residential building with cast-in-place reinforced concrete slabs constructed in 1953. The assessment involved non-destructive inspections, double flat-jack and shear tests, and geophysical site surveys. A finite element model was developed using Midas Gen software v2020 and analyzed through linear response spectrum and nonlinear pushover analyses based on TBSC-18 and SRMGHS-17. The modulus of elasticity ranged from 200.2 MPa to 1062.2 MPa, and bed joint shear strength varied between 0.50 MPa and 0.79 MPa. The building satisfied inter-story drift criteria for limited damage (SL-3), controlled damage (SL-2), and pre-collapse (SL-1). However, it failed to meet the shear force requirements at all levels. Pushover analysis revealed ultimate lateral capacities of 11,997 kN in the x-direction and 16,209 kN in the y-direction. The findings highlight the shear vulnerability of such hybrid systems and underscore the importance of combining experimental characterization with numerical modeling to develop effective retrofitting strategies. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

23 pages, 3753 KB  
Article
In-Plane Strengthening of Unreinforced Masonry Walls with Discrete Glass Fiber-Reinforced Polymer Grid Strips Bonded with Sprayed Polyurea
by Piyong Yu, Pedro Silva and Antonio Nanni
Materials 2025, 18(4), 771; https://doi.org/10.3390/ma18040771 - 10 Feb 2025
Cited by 3 | Viewed by 1483
Abstract
In this study, unreinforced masonry (URM) walls constructed from concrete blocks and clay bricks were strengthened using horizontally and vertically oriented glass fiber-reinforced polymer (GFRP) grid strips bonded with sprayed polyurea. The walls were subjected to diagonal compression loading until failure. The results [...] Read more.
In this study, unreinforced masonry (URM) walls constructed from concrete blocks and clay bricks were strengthened using horizontally and vertically oriented glass fiber-reinforced polymer (GFRP) grid strips bonded with sprayed polyurea. The walls were subjected to diagonal compression loading until failure. The results demonstrated a significant improvement in both the shear capacity and pseudo-ductility of the strengthened URM walls compared to their unstrengthened counterparts. The primary conclusions drawn from this research are as follows: (1) the maximum strain in the vertical GFRP strips increased with the higher axial stiffness of the strips; (2) the discrete vertical strips contributed substantially to enhancing the shear capacity and pseudo-ductility of the URM walls; (3) increasing the axial stiffness of the vertical strips can alter the failure mode of the walls, shifting it from joint failure to tension or compression failure of the blocks or bricks; (4) a reduction factor is necessary to account for the potential asymmetrical performance of double-sided strengthening schemes applied to URM walls. The experimental program was reported in a previous publication and additional information is presented in this paper. Full article
Show Figures

Figure 1

25 pages, 4289 KB  
Article
Extending a Macro-Element Approach for the Modeling of 3D Masonry Structures Under Transient Dynamic Loading
by Damien Decret, Yann Malecot, Yannick Sieffert, Florent Vieux-Champagne and Laurent Daudeville
Appl. Sci. 2024, 14(23), 11080; https://doi.org/10.3390/app142311080 - 28 Nov 2024
Cited by 1 | Viewed by 1398
Abstract
Masonry structures, particularly those used in developing countries and in historic buildings, typically consist of unreinforced masonry (URM) walls connected by timber or reinforced concrete elements. This study proposes enhancements to the existing two-dimensional (2D) deformable frame model (DFM) to enhance its ability [...] Read more.
Masonry structures, particularly those used in developing countries and in historic buildings, typically consist of unreinforced masonry (URM) walls connected by timber or reinforced concrete elements. This study proposes enhancements to the existing two-dimensional (2D) deformable frame model (DFM) to enhance its ability in simulating masonry walls with a specific focus on accurately predicting the transient dynamic response of three-dimensional (3D) masonry structures while maintaining a minimal number of degrees of freedom (DOF). For the modeling of URM walls, the DFM framework employs elastic beams and diagonal struts with nonlinear constitutive behavior. Structural elements, such as reinforced concrete or timber reinforcements, are represented using conventional beam finite elements. This paper first reviewed the current DFM configuration, which primarily addresses the in-plane (IP) behavior of URM structures. It then introduced modifications tailored for 3D structural analysis. The reliability of the enhanced model was validated through two approaches. First, a modal analysis compared the results from the updated DFM with those from a reference 3D model based on cubic finite elements. Second, a shaking table experiment conducted on a half-scale masonry house was simulated. The findings demonstrate that, despite its limited number of DOF, the updated DFM effectively captures the main natural vibration modes. Furthermore, it shows the model’s ability to predict the nonlinear transient dynamic response of 3D masonry structures with accuracy and limited computational time. Full article
(This article belongs to the Section Civil Engineering)
Show Figures

Figure 1

22 pages, 4167 KB  
Article
Evaluating the Role of Mortar Composition on the Cyclic Behavior of Unreinforced Masonry Shear Walls
by Meera Ramesh, Rafael Ramirez, Miguel Azenha and Paulo B. Lourenço
Materials 2024, 17(18), 4443; https://doi.org/10.3390/ma17184443 - 10 Sep 2024
Cited by 4 | Viewed by 1983
Abstract
The mechanical behavior of unreinforced masonry (URM) shear walls under in-plane cyclic loading is crucial for assessing their seismic performance. Although masonry structures have been extensively studied, the specific influence of varying lime content in cement-lime mortars on the cyclic behavior of URM [...] Read more.
The mechanical behavior of unreinforced masonry (URM) shear walls under in-plane cyclic loading is crucial for assessing their seismic performance. Although masonry structures have been extensively studied, the specific influence of varying lime content in cement-lime mortars on the cyclic behavior of URM walls has not been adequately explored. This study addresses this gap by experimentally evaluating the effects of three mortar mixes with increasing lime content, 1:0:5, 1:1:6, and 1:2:9 (cement:lime:sand, by volume), on the cyclic performance of brick URM walls. Nine single-leaf wall specimens 900 mm × 900 mm were constructed and subjected to combined vertical compression and horizontal cyclic loading. Key parameters such as drift capacity, stiffness degradation, and energy dissipation were measured. The results indicated that the inclusion of lime leads to a moderate improvement in drift capacity and ductility of the walls, with the 1:1:6 mix showing the highest lateral capacity (0.55 MPa), drift at cracking (0.08%), and drift at peak capacity (0.31%). Stiffness degradation and energy dissipation were found to be comparable across all mortar types. These findings suggest that partial substitution of cement with lime can enhance certain aspects of masonry performance. Further research is recommended to optimize mortar compositions for unreinforced masonry applications. Full article
(This article belongs to the Special Issue Advance in Sustainable Construction Materials, Second Volume)
Show Figures

Figure 1

27 pages, 12841 KB  
Article
The Influence of the Aggregate Configuration on the Seismic Assessment of Unreinforced Masonry Buildings in Historic Urban Areas
by Valentina Cima, Valentina Tomei, Ernesto Grande and Maura Imbimbo
Sustainability 2024, 16(10), 4172; https://doi.org/10.3390/su16104172 - 16 May 2024
Cited by 16 | Viewed by 2083
Abstract
Unreinforced masonry (URM) buildings in historic urban areas of European countries are generally clustered in an aggregate configuration and are often characterized by façade walls mutually interconnected with adjacent ones. As a result, the seismic performance of buildings in an aggregate configuration can [...] Read more.
Unreinforced masonry (URM) buildings in historic urban areas of European countries are generally clustered in an aggregate configuration and are often characterized by façade walls mutually interconnected with adjacent ones. As a result, the seismic performance of buildings in an aggregate configuration can be affected by the mutual interaction between the adjacent units. This interaction, often called the aggregate effect, could significantly influence the level of the seismic vulnerability of URM buildings in aggregate configuration toward in-plane and out-of-plane mechanisms, the latter being the object of the present paper. Traditional methods for assessing the seismic vulnerability of URM buildings neglect the interactions between adjacent buildings, potentially underestimating the actual vulnerability. This study aims to derive fragility curves specific for UMR buildings in aggregate configuration and proposes an innovative methodology that introduces the aggregate effect into an analytical approach, previously developed by the authors for isolated URM buildings. The aggregate effect is modeled by accounting for the friction forces arising among adjacent facades during the development of out-of-plane overturning mechanisms by considering different scenarios, based on how façade walls interact with neighboring structures (e.g., whether they are connected to transverse and/or lateral coplanar ones). The proposed approach is applied to a real case study of an Italian historical center. The obtained results demonstrate that the aggregate effect significantly influences the fragility curves of URM buildings arranged in aggregate configurations. This highlights the importance of considering this effect and the usefulness of the proposed approach for large-scale assessments of seismic vulnerability in historic urban areas, contributing to sustainable disaster risk prevention. Full article
Show Figures

Figure 1

22 pages, 3805 KB  
Article
A New Macro-Element for Predicting the Behavior of Masonry Structures under In-Plane Cyclic Loading
by Damien Decret, Yann Malecot, Yannick Sieffert, Florent Vieux-Champagne and Laurent Daudeville
Buildings 2024, 14(3), 768; https://doi.org/10.3390/buildings14030768 - 12 Mar 2024
Cited by 6 | Viewed by 2175
Abstract
A new macro model for the finite element modeling of unreinforced masonry (URM) exhibiting in-plane nonlinear cyclic behavior is proposed. The ultimate objective is to predict the seismic response of multi-story URM buildings. The macro model enables the modeling of URM shear walls [...] Read more.
A new macro model for the finite element modeling of unreinforced masonry (URM) exhibiting in-plane nonlinear cyclic behavior is proposed. The ultimate objective is to predict the seismic response of multi-story URM buildings. The macro model enables the modeling of URM shear walls with a limited number of degrees of freedom (DOF) at low computation times. The macro model consists of a deformable elastic frame supported by diagonal struts with nonlinear behavior aiming to capture all dissipative phenomena occurring during seismic events. The nonlinear constitutive behavior of diagonal struts is inspired by models documented in the literature, ensuring a robust foundation for the proposed approach. This paper first provides a comprehensive review of the principal models currently available for URM analysis. It then articulates the rationale behind the development of this new numerical model, aiming to address the limitations encountered in existing methodologies and to offer a simple and fast tool for predicting the seismic behavior of URM buildings. Afterward, the new model is presented and tested with the simulations of two experimental campaigns performed on different URM walls. The comparison between experimental and numerical results shows that with a limited number of DOF and parameters, it is possible to obtain a prediction of the experimental results with satisfying accuracy. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

32 pages, 43577 KB  
Article
Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
by Seyyed Motasam Hashemi and Ashraf Ayoub
Buildings 2024, 14(1), 257; https://doi.org/10.3390/buildings14010257 - 17 Jan 2024
Cited by 6 | Viewed by 2228
Abstract
Carbon fibre-reinforced polymer (CFRP) emerges as a viable solution for reinforcing unreinforced masonry (URM) walls subjected to shear loads. While masonry structures are straightforward to construct, the complexity of the construction materials, especially in terms of their mechanical properties, poses challenges for numerical [...] Read more.
Carbon fibre-reinforced polymer (CFRP) emerges as a viable solution for reinforcing unreinforced masonry (URM) walls subjected to shear loads. While masonry structures are straightforward to construct, the complexity of the construction materials, especially in terms of their mechanical properties, poses challenges for numerical studies of their structural behaviour. Walls, being fundamental components in masonry construction, play a crucial role in transferring both horizontal and vertical lateral forces. This study investigates the enhancement of masonry wall behaviour through the reinforcement of CFRP. CFRP reinforcement increases ductility and strength, reducing the risk of failure under shear conditions. Additionally, CFRP composites present a practical solution to strengthening masonry structures compared to traditional reinforcement. However, brick, mortar, and CFRP have not been thoroughly investigated. Experimental tests on the bond behaviour of different configurations of CFRP-retrofitted masonry triplets have not been performed before and are therefore presented in this paper. Triplet specimens, comprising three bricks and two mortar joints, both with and without CFRP strengthening, were subjected to bond testing. The study affirms that masonry triplets strengthened with CFRP under shear loads exhibit strength levels at least four to six times greater than those without CFRP. The experimental work was carried out with eight different CFRP configurations on triplet masonry, and each test was repeated four times. Further, the bond stress-slip relationship in the case of masonry triplets with and without CFRP was predicted with new mathematical equations based on the conducted test results. These equations were included in the commercial finite element software ANSYS and used to conduct simulations of CFRP-reinforced masonry triplets. The numerical results indicate good agreement between the finite element model and the test results. The outcome of this research improves the current knowledge on the use of CFRP to reinforce masonry walls with brick and mortar, which will contribute to the understanding of the effect of CFRP on masonry structures. Full article
Show Figures

Figure 1

Back to TopTop