Effect of Earthing Enhancing Compound (EEC) on Improving Tower Footing Resistance of a 500 kV Tower in a Rocky Area

  • Nur Alia Farina Mohd Nasir,
  • Mohd Zainal Abidin Ab Kadir,
  • Miszaina Osman,
  • Muhamad Safwan Abd Rahman,
  • Ungku Anisa Ungku Amirulddin,
  • Mohd Solehin Mohd Nasir,
  • Nur Hazirah Zaini and
  • Nik Hakimi Nik Ali

18 June 2021

This paper presents a comparative analysis of different earthing designs’ performances, with particular interest on the use of earthing enhancing compound (EEC) for a selected earthing design of 500 kV transmission towers in a rocky soil, using the S...

  • Article
  • Open Access
1 Citations
1,960 Views
25 Pages

11 April 2025

This paper presents a comprehensive assessment of the accuracy of high-frequency (HF) earth meters in measuring the tower-footing ground resistance of transmission line structures, combining simulation and experimental results. The findings demonstra...

  • Article
  • Open Access
3 Citations
4,449 Views
19 Pages

Influence of Lightning Current Parameters and Earthing System Designs on Tower Footing Impedance of 500 kV Lines

  • Nur Alia Farina Mohamad Nasir,
  • Mohd Zainal Abidin Ab Kadir,
  • Miszaina Osman,
  • Muhamad Safwan Abd Rahman,
  • Ungku Anisa Ungku Amirulddin,
  • Mohd Solehin Mohd Nasir,
  • Nur Hazirah Zaini and
  • Nik Hakimi Nik Ali

4 August 2021

This paper presents an optimum earthing system design for improving the lightning performance of a 500 kV transmission line for its sustainable operation. The study includes an interpretation of the soil profile and compares the results between defau...

  • Article
  • Open Access
2 Citations
2,778 Views
17 Pages

10 December 2020

Earthing and protective devices such as line surge arrestors (LSAs) play an important role in areas with high lightning occurrence for overhead HVAC lines’ performance. A lightning stroke of high magnitude can lead to back flash-overs, and the...

  • Article
  • Open Access
3 Citations
2,641 Views
21 Pages

7 August 2023

Backflashover rate (BFR) is strongly dependent on the cumulative peak current distribution (CCD) adopted in the calculations. An original aspect of the present work is that such dependence is simultaneously assessed in estimating the probability of t...

  • Article
  • Open Access
8 Citations
6,839 Views
20 Pages

Impact of Earthing System Designs and Soil Characteristics on Tower Footing Impedance and Ground Potential Rise: A Modelling Approach for Sustainable Power Operation

  • Nur Alia Farina Mohamad Nasir,
  • Mohd Zainal Abidin Ab Kadir,
  • Miszaina Osman,
  • Muhamad Safwan Abd Rahman,
  • Ungku Anisa Ungku Amirulddin,
  • Mohd Solehin Mohd Nasir,
  • Nur Hazirah Zaini and
  • Nik Hakimi Nik Ali

27 July 2021

Improving a tower earthing system by reducing the impedance is an effective solution to prevent back flashover from occurring and thus maintaining the sustainable operation of power supply. Knowledge of the soil and earthing structure is an important...

  • Article
  • Open Access
11 Citations
3,538 Views
19 Pages

8 November 2021

End resistance is a dominant variable in the sinking process of super-sized caisson foundation, which is of great importance to the safe sinking of the caisson foundation. Based on soil excavation process of super large caisson foundation of the main...