Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (73)

Search Parameters:
Keywords = refractive index and gas sensing

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 9434 KB  
Article
High-Sensitivity Bistable Biosensor Based on the Photonic Crystal Fabry-Pérot Cavity with Weyl Semimetal
by Shiqi Yang, Daohong Xiao, Xiangjie Luo, Kui Wang, Haishan Tian and Leyong Jiang
Photonics 2026, 13(8), 716; https://doi.org/10.3390/photonics13080716 - 29 Jul 2026
Abstract
Optical bistability (OB) with low threshold and high tunability is crucial for advanced photonic devices. This work theoretically investigates low-threshold and tunable OB in a one-dimensional photonic crystal Fabry-Pérot (FP) cavity embedded with a Weyl semimetal (WSM) layer. By combining the local field [...] Read more.
Optical bistability (OB) with low threshold and high tunability is crucial for advanced photonic devices. This work theoretically investigates low-threshold and tunable OB in a one-dimensional photonic crystal Fabry-Pérot (FP) cavity embedded with a Weyl semimetal (WSM) layer. By combining the local field enhancement of the cavity and the large third-order nonlinear refractive index of the WSM, we achieve OB in the terahertz regime with a low threshold of ~105 V/m. Furthermore, the OB threshold and hysteresis width can be flexibly manipulated via the Fermi energy of WSM, incident angle, photonic crystal period, the refractive index of the dielectric inside the cavity, and the position of the WSM inside the FP cavity. Moreover, based on the high sensitivity of switching thresholds to refractive index and displacement variations, we also propose a dual-parameter sensing scheme. This exhibits excellent sensing performance for gas sensing (sensitivity up to 96.48 × 105 V/m·RIU) and high sensitivity for displacement sensing (0.91 × 106 V/m·μm). We believe that the above results can provide reference schemes for nonlinear photonic devices. Full article
(This article belongs to the Section Lasers, Light Sources and Sensors)
Show Figures

Figure 1

58 pages, 7265 KB  
Review
Review of Optical Fiber and Integrated Photonic Sensors for Industry and Smart Manufacturing: Technologies, Applications, Structural Health Monitoring and AI-Enabled Sensing
by Giannis Poulopoulos and Hercules Avramopoulos
Sensors 2026, 26(11), 3581; https://doi.org/10.3390/s26113581 - 4 Jun 2026
Viewed by 1133
Abstract
Smart manufacturing, Industry 4.0, and cyber-physical systems (CPSs) require sensing architectures capable of resolving both spatially distributed asset behavior and highly localized process states. This review examines optical fiber sensors (OFSs) and integrated photonic sensors for industrial monitoring through a deployment-oriented, multi-scale perspective. [...] Read more.
Smart manufacturing, Industry 4.0, and cyber-physical systems (CPSs) require sensing architectures capable of resolving both spatially distributed asset behavior and highly localized process states. This review examines optical fiber sensors (OFSs) and integrated photonic sensors for industrial monitoring through a deployment-oriented, multi-scale perspective. The discussion covers five major application regimes: continuous infrastructure surveillance, structural health monitoring (SHM) of load-bearing composites, dynamic condition monitoring of machinery, in situ observability in advanced manufacturing, and localized chemical or gas sensing. Extended fiber-optic networks, including distributed fiber-optic sensing (DFOS) based on Rayleigh, Raman, and Brillouin scattering, together with multiplexed fiber Bragg grating (FBG) sensors, provide passive, embeddable, and remotely interrogated monitoring for large-scale assets and harsh environments. Photonic integrated circuits (PICs) shift transduction to compact node-level devices for localized thermal, mechanical, refractive-index, absorption, vibration, and inertial measurements, while plasmonic and dielectric nanophotonic sensors extend optical monitoring toward surface-selective and chemically specific detection. Across these platforms, digital signal processing (DSP), machine learning (ML), sensor fusion, and digital-twin (DT) coupling are treated as artificial-intelligence-enabled (AI-enabled) layers for signal recovery, inverse mapping, uncertainty reduction, and predictive maintenance. The review argues that scalable industrial adoption is less limited by sensing physics than by the complete deployment chain: packaging, fiber–chip interfacing, calibration stability, interrogation robustness, and AI-enabled data interpretation. This manuscript is structured as a deployment-oriented narrative review of optical fiber and integrated photonic sensors for industrial monitoring and smart manufacturing. Full article
Show Figures

Figure 1

12 pages, 2256 KB  
Article
CO2 Sensing Characteristics of 2H-MoS2-Coated D-Shaped Optical Fiber Sensors
by Han-Mam Kang, Hyung-il Jang, Tae-Jung Ahn and Min-Ki Kwon
Micromachines 2026, 17(3), 341; https://doi.org/10.3390/mi17030341 - 11 Mar 2026
Cited by 1 | Viewed by 628
Abstract
In this study, a highly crystalline 2H (hexagonal)-phase MoS2 sensing layer with a precisely controlled crystal structure was realized through a combination of DC sputtering and sulfurization annealing processes, and subsequently integrated with a D-shaped optical fiber to develop a highly sensitive [...] Read more.
In this study, a highly crystalline 2H (hexagonal)-phase MoS2 sensing layer with a precisely controlled crystal structure was realized through a combination of DC sputtering and sulfurization annealing processes, and subsequently integrated with a D-shaped optical fiber to develop a highly sensitive carbon dioxide (CO2) sensor. Conventionally sputtered MoS2 thin films often suffer from the presence of unstable metallic 1T (tetragonal) phases and a high density of sulfur vacancies, which significantly degrade sensor reversibility and long-term stability. Here, high-temperature annealing under a sulfur-rich atmosphere was employed to induce a complete phase transition from the metastable 1T phase to the stable semiconducting 2H phase, while simultaneously healing sulfur vacancies. Enhanced crystallinity was confirmed by Raman spectroscopy. The fabricated sensor exhibited excellent linearity (R2 > 0.99) and markedly improved repeatability over a CO2 concentration range of 1000–10,000 ppm. This significant performance enhancement is attributed to reversible charge transfer induced by sulfur vacancy passivation, which modulates the complex refractive index of the MoS2 layer and optimizes optical interaction with the evanescent field of the D-shaped fiber. The phase engineering and defect-healing strategy presented in this work effectively addresses the drift issues commonly observed in conventional electrical gas sensors and provides a crucial pathway toward the realization of high-performance optical gas sensors. Full article
(This article belongs to the Special Issue Gas Sensors and Electronic Noses)
Show Figures

Figure 1

28 pages, 4574 KB  
Review
Flatland Metasurfaces for Optical Gas Sensing
by Muhammad A. Butt
Sensors 2026, 26(4), 1293; https://doi.org/10.3390/s26041293 - 17 Feb 2026
Cited by 1 | Viewed by 1923
Abstract
Flatland metasurfaces provide a fundamentally distinct approach to optical gas sensing by confining light–matter interaction to planar, subwavelength interfaces, where resonant energy storage and near-field enhancement replace extended optical path lengths. This review presents a physics-driven perspective on metasurface-enabled gas sensing, focusing on [...] Read more.
Flatland metasurfaces provide a fundamentally distinct approach to optical gas sensing by confining light–matter interaction to planar, subwavelength interfaces, where resonant energy storage and near-field enhancement replace extended optical path lengths. This review presents a physics-driven perspective on metasurface-enabled gas sensing, focusing on how gaseous analytes perturb the complex eigenmodes of engineered planar resonators. Diverse sensing modalities, including enhanced molecular absorption, refractive index-induced resonance shifts, loss modulation, polarization conversion, and chemo-optical transduction, are unified within a common perturbative framework that links sensitivity to mode confinement, quality factor, and analyte overlap. The analysis highlights fundamental trade-offs imposed by material dispersion, intrinsic loss, and radiation balance across plasmonic, dielectric, polaritonic, and hybrid metasurface platforms operating from the visible to the terahertz regime. Attention is given to the limits of chemical selectivity in flatland architectures and to the role of functional materials, multimodal transduction, and computational inference in addressing these constraints. System-level considerations, including thermal stability, fabrication tolerance, and integration with detectors and electronics, are identified as critical determinants of real-world performance. By consolidating disparate approaches within a unified flatland framework, this review provides physical insight and design guidance for the development of compact, integrable, and application-specific optical gas sensing systems. Full article
Show Figures

Figure 1

9 pages, 3690 KB  
Proceeding Paper
A Hexa-Band Terahertz Metamaterial Absorber Using a Symmetrical Boss Cross Structure with Biomedical Applications
by Santosh Kumar Mishra, Uddipan Nath, Sagnik Banerjee, Bhargav Appasani, Omprakash Acharya, Sunil Kumar Mishra, Amitkumar V. Jha, Avireni Srinivasulu and Cristian Ravariu
Eng. Proc. 2025, 87(1), 114; https://doi.org/10.3390/engproc2025087114 - 31 Oct 2025
Cited by 1 | Viewed by 1109
Abstract
Terahertz (THz) metamaterial absorbers have become a prominent research topic in recent years. In this paper, a hexa-band metamaterial absorber is designed for bio-medical sensing applications. The design can detect changes in the surrounding medium’s refractive index and operates in the refractive index [...] Read more.
Terahertz (THz) metamaterial absorbers have become a prominent research topic in recent years. In this paper, a hexa-band metamaterial absorber is designed for bio-medical sensing applications. The design can detect changes in the surrounding medium’s refractive index and operates in the refractive index range of 1.3–1.4, with six prominent absorption peaks. The proposed structure comprises a square ring resonator made up of gold with a boss-cross structure at the center, on top of a Gallium Arsenide (GaAs) substrate having a thickness of 8 μm. When the surrounding medium’s refractive index is 1.4, it offers six absorption peaks at 0.537 THz, 2.573 THz, 3.025 THz, 3.146 THz, 3.489 THz, 3.7348 THz, with corresponding peak absorption of 75%, 92.9%, 98.4%, 98.71%, 94.1%, and 99.34%, respectively. The structure has been designed at n = 1.4 instead of n = 1, as several biological specimens, such as blood, breast cells, etc., have refractive index in the range of 1.3–1.4, and it offers 6 bands for n = 1.4. This choice was made because many biomedical applications have a refractive index around 1.4. The design parameters were selected through a parametric analysis, so as to achieve maximum absorption peaks. The design has also been tested with different polarization angles, and it has been discovered that the absorber is polarization-insensitive. This design can inspire future research on the biomedical application of THz absorbers. Full article
(This article belongs to the Proceedings of The 5th International Electronic Conference on Applied Sciences)
Show Figures

Figure 1

17 pages, 2192 KB  
Article
Cascaded MZI and FPI Sensor for Simultaneous Measurement of Air Pressure and Temperature Using Capillary Fiber and Dual-Core Fiber
by Tongtong Zhu, Xintong Zhong, Xinhao Guo, Qipeng Huang, Xiaoyong Chen, Chuanxin Teng, Peng-Cheng Li, Xuehao Hu and Hang Qu
Photonics 2025, 12(11), 1047; https://doi.org/10.3390/photonics12111047 - 23 Oct 2025
Cited by 2 | Viewed by 928
Abstract
In this paper, we propose and experimentally demonstrate a dual-parameter fiber optic sensor, which combines a Fabry–Perot interferometer (FPI) and a Mach–Zehnder interferometer (MZI) for simultaneous pressure and temperature sensing. The Fabry–Perot (FP) cavity is formed by sandwiching a capillary fiber between a [...] Read more.
In this paper, we propose and experimentally demonstrate a dual-parameter fiber optic sensor, which combines a Fabry–Perot interferometer (FPI) and a Mach–Zehnder interferometer (MZI) for simultaneous pressure and temperature sensing. The Fabry–Perot (FP) cavity is formed by sandwiching a capillary fiber between a single-mode fiber and a dual-core fiber (DCF). A fluid channel is very close to the central core of the DCF. By precisely drilling micro-air chambers in the annular cladding of a capillary fiber (CF) using a femtosecond laser, external air pressure can directly affect the capillary fiber and induce changes in the refractive index of the air in the CF. The F-P cavity achieves a pressure sensitivity of 3.67 nm/MPa with a temperature cross-sensitivity of 2.82 pm/°C. The MZI is constructed using a dual-core fiber filled with silicone oil in the fluidic channel, which enhances temperature sensitivity through the thermo-optic effect. The MZI sensor exhibits a nonlinear temperature response with an average sensitivity of 103.43 pm/°C. The corresponding pressure cross-sensitivity is about –0.11 nm/MPa. Due to very low cross-sensitivity, simultaneous measurement of temperature and gas pressure is feasible. In addition, we implement a variant by replacing silicone oil with a UV-curable adhesive, which delivers a comparable FP-based pressure sensitivity of ~3.93 nm/MPa while yielding an MZI-based temperature sensitivity of 71.7 pm/°C and potentially improved long-term stability. Full article
(This article belongs to the Special Issue Advances in Optical Fiber Sensing Technology)
Show Figures

Figure 1

14 pages, 1220 KB  
Article
High-Sensitivity Terahertz Biosensor Based on a Multi-Layer Hybrid Structure Consisting of a Defect Mode and Graphene
by Hai Hu, Shiying Mo, Yangbao Deng and Zhengchun Zhao
Biosensors 2025, 15(10), 702; https://doi.org/10.3390/bios15100702 - 17 Oct 2025
Cited by 1 | Viewed by 1086
Abstract
A high-sensitivity terahertz (THz) biosensor is proposed in this paper based on a multi-layer hybrid structure consisting of a defect mode and graphene with a truncation layer. This biosensor is based on symmetrical Bragg reflectors with a defect layer and graphene with a [...] Read more.
A high-sensitivity terahertz (THz) biosensor is proposed in this paper based on a multi-layer hybrid structure consisting of a defect mode and graphene with a truncation layer. This biosensor is based on symmetrical Bragg reflectors with a defect layer and graphene with a truncation layer, which effectively comprise a multi-layer hybrid resonance excitation structure. The high sensitivity of this biosensor is developed through defect mode resonance, and the resonance reflection peak is made sharper and more sensitive by using graphene with a truncation layer. After testing and analysis, the sensitivity of this biosensor structure is greatly affected by the refractive index and thickness of the sensing medium. By setting parameters appropriately, the composite structure can be used as both a liquid biosensor and a gas biosensor, the maximum sensitivity of which can surpass 2000°/RIU, while an FOM value of 22,500 RIU−1 can be achieved. At the same time, when the refractive index of the liquid sensing medium changes to 0.01 relative to water (the same applies to changes in the gas sensing medium), the sensitivity of this structure still exceeds 600°/RIU, demonstrating that this biosensor has advantages including high sensitivity, a high FOM, wide applicability, and slow sensitivity attenuation. Therefore, the sensing scheme proposed in this paper has potential application prospects in the field of biosensing based on micro/nanostructures due to its simple structure, low requirements for processing conditions, and high sensitivity. Full article
(This article belongs to the Special Issue Nanophotonics and Surface Waves in Biosensing Applications)
Show Figures

Figure 1

13 pages, 3092 KB  
Article
Carbon Dioxide Gas Sensor Based on Terahertz Metasurface with Asymmetric Cross-Shaped Holes Empowered by Quasi-Bound States in the Continuum
by Kai He and Tian Ma
Sensors 2025, 25(13), 4178; https://doi.org/10.3390/s25134178 - 4 Jul 2025
Cited by 6 | Viewed by 1604
Abstract
In this paper, a novel type of polarization-insensitive terahertz metal metasurface with cross-shaped holes is presented, which is designed based on the theory of bound states in continuous media. The fundamental unit of the metasurface comprises a metal tungsten sheet with a cross-shaped [...] Read more.
In this paper, a novel type of polarization-insensitive terahertz metal metasurface with cross-shaped holes is presented, which is designed based on the theory of bound states in continuous media. The fundamental unit of the metasurface comprises a metal tungsten sheet with a cross-shaped hole structure. A thorough analysis of the optical properties and the quasi-BIC response is conducted using the finite element method. Utilizing the symmetry-breaking theory, the symmetry of the metal metasurface is broken, allowing the excitation of double quasi-BIC resonance modes with a high quality factor and high sensitivity to be achieved. Analysis of the multipole power distribution diagram and the spatial distribution of the electric field at the two quasi-BIC resonances verifies that the two quasi-BIC resonances of the metasurface are excited by electric dipoles and electric quadrupoles, respectively. Further simulation analysis demonstrates that the refractive index sensitivities of the two quasi-BIC modes of the metasurface reach 404.5 GHz/RIU and 578.6 GHz/RIU, respectively. Finally, the functional material PHMB is introduced into the metasurface to achieve highly sensitive sensing and detection of CO2 gas concentrations. The proposed metallic metasurface structure exhibits significant advantages, including high sensitivity, ease of preparation, and a high Q-value, which renders it highly promising for a broad range of applications in the domains of terahertz biosensing and highly sensitive gas sensing. Full article
(This article belongs to the Special Issue The Advanced Flexible Electronic Devices: 2nd Edition)
Show Figures

Figure 1

13 pages, 2468 KB  
Article
On-Chip Silicon Bragg-Grating-Waveguide-Based Polymer Slot for Gas Sensing
by Merna Khafagy, Maira Khafagy, Passant Hesham and Mohamed A. Swillam
Photonics 2025, 12(6), 608; https://doi.org/10.3390/photonics12060608 - 12 Jun 2025
Cited by 7 | Viewed by 2500
Abstract
This work presents a novel CO2 gas sensor based on a slotted polymer-phaseshift Bragg grating (SP-PSBG) waveguide filled with polyhexamethylene biguanide (PHMB) as the sensing medium. The transmission resonance, characterized by a narrow peak with a full width at half maximum [...] Read more.
This work presents a novel CO2 gas sensor based on a slotted polymer-phaseshift Bragg grating (SP-PSBG) waveguide filled with polyhexamethylene biguanide (PHMB) as the sensing medium. The transmission resonance, characterized by a narrow peak with a full width at half maximum (FWHM) of 1.6 nm within the Bragg grating bandgap, is highly responsive to refractive index changes in PHMB caused by variations in CO2 concentration. Numerical simulations demonstrate a sensitivity of 14.4 pm/ppm, outperforming conventional gas sensors based on functional material coatings. This enhanced performance comes from the direct interaction between the PHMB-filled resonant structure and the cladding that contains CO2 molecules, eliminating the need for polymer-coated cladding layers. The optimization approach employed in this design focuses on maximizing the optical confinement factor within the PHMB-filled slot, leading to an effective overlap between the guided optical mode and the sensing material. Full article
(This article belongs to the Special Issue Advances in Integrated Photonics)
Show Figures

Figure 1

11 pages, 2104 KB  
Article
High-Precision Interferometric Measurements of Gas Refractive Index Using Homodyne Detection
by Yanan Miao, Fang Xie, Wentao Feng, Yifeng Zhu, Xun Zhang and Fang Liu
Sensors 2025, 25(11), 3519; https://doi.org/10.3390/s25113519 - 3 Jun 2025
Cited by 2 | Viewed by 1884
Abstract
Balanced homodyne detection, which offers advantages that include low noise and strong anti-interference capabilities, is commonly used as a detection method in quantum metrology. In this article, we propose application of the balanced homodyne detection technique to the gas sensing and measurement field. [...] Read more.
Balanced homodyne detection, which offers advantages that include low noise and strong anti-interference capabilities, is commonly used as a detection method in quantum metrology. In this article, we propose application of the balanced homodyne detection technique to the gas sensing and measurement field. By constructing a Mach–Zehnder interferometer based on balanced homodyne detection, we realize high-precision measurement of the refractive index of air. The device exhibits interference efficiency of 99% and a common-mode rejection ratio of 40 dB, thus enabling dynamic monitoring of optical phase changes. Under conditions that include a stabilized temperature of 25 °C, atmospheric pressure of 100.08 kPa, and relative humidity of 30%, the refractive index of air was measured experimentally to be n=1.0002711 with a measured minimum standard deviation of 1×107. The proposed technique provides high measurement sensitivity and stability, and it also offers the advantage of noncontact measurement. Furthermore, the proposed scheme is applicable to both measurement and dynamic sensing of the refractive indices of gases, along with sensing and measurement of transparent liquids and biological samples. Full article
(This article belongs to the Special Issue Advanced Sensors for Gas Monitoring)
Show Figures

Figure 1

13 pages, 3847 KB  
Article
Hybrid Growth of Clad Crystalline Sapphire Fibers for Ultra-High-Temperature (>1500 °C) Fiber Optic Sensors
by Mohammad Ahsanul Kabir, Kai-Cheng Wu, Kai-Ting Chou, Fang Luo and Shizhuo Yin
Photonics 2025, 12(4), 299; https://doi.org/10.3390/photonics12040299 - 25 Mar 2025
Cited by 3 | Viewed by 1948
Abstract
Ultra-high-temperature (>1500 °C) sensors play vital roles in ensuring operational excellence in variety of energy-related applications, such as power plant boilers and gas turbine engines. Crystalline sapphire fibers have enormous potential to replace conventional expensive precious metal (e.g., Pt/Rh)-based high-temperature (>1500 °C) sensors [...] Read more.
Ultra-high-temperature (>1500 °C) sensors play vital roles in ensuring operational excellence in variety of energy-related applications, such as power plant boilers and gas turbine engines. Crystalline sapphire fibers have enormous potential to replace conventional expensive precious metal (e.g., Pt/Rh)-based high-temperature (>1500 °C) sensors by offering higher environmental robustness and distributed sensing capabilities. However, a lack of proper cladding substantially compromises the performance of the sensor. To overcome this fundamental limitation, we develop a hybrid growing method to fabricate low-loss clad crystalline sapphire fibers. We grow a higher-refractive-index doped crystalline sapphire fiber core using the laser-heated pedestal growth (LHPG) method and lower-refractive-index undoped crystalline sapphire fiber cladding using the liquid-phase epitaxy (LPE) method. Furthermore, due to the existence of this cladding layer, a single mode of operation can be achieved at a core diameter size of 30 μm. The experimental results confirm that the grown clad crystalline sapphire fiber can survive in extremely high-temperature (>1500 °C) harsh environments due to the matched coefficient of thermal expansion (CTE) between the fiber core and the cladding. The numerical results also indicate a temperature sensing accuracy of 3.5 °C. This opens the door for developing point and distributed fiber sensor networks capable of enduring extremely harsh environments at extremely high temperatures. Full article
Show Figures

Figure 1

25 pages, 30298 KB  
Review
Topological Photonic Crystal Sensors: Fundamental Principles, Recent Advances, and Emerging Applications
by Israa Abood, Sayed El. Soliman, Wenlong He and Zhengbiao Ouyang
Sensors 2025, 25(5), 1455; https://doi.org/10.3390/s25051455 - 27 Feb 2025
Cited by 26 | Viewed by 6960
Abstract
Topological photonic sensors have emerged as a breakthrough in modern optical sensing by integrating topological protection and light confinement mechanisms such as topological states, quasi-bound states in the continuum (quasi-BICs), and Tamm plasmon polaritons (TPPs). These devices exhibit exceptional sensitivity and high-Q [...] Read more.
Topological photonic sensors have emerged as a breakthrough in modern optical sensing by integrating topological protection and light confinement mechanisms such as topological states, quasi-bound states in the continuum (quasi-BICs), and Tamm plasmon polaritons (TPPs). These devices exhibit exceptional sensitivity and high-Q resonances, making them ideal for high-precision environmental monitoring, biomedical diagnostics, and industrial sensing applications. This review explores the foundational physics and diverse sensor architectures, from refractive index sensors and biosensors to gas and thermal sensors, emphasizing their working principles and performance metrics. We further examine the challenges of achieving ultrahigh-Q operation in practical devices, limitations in multiparameter sensing, and design complexity. We propose physics-driven solutions to overcome these barriers, such as integrating Weyl semimetals, graphene-based heterostructures, and non-Hermitian photonic systems. This comparative study highlights the transformative impact of topological photonic sensors in achieving ultra-sensitive detection across multiple fields. Full article
(This article belongs to the Special Issue Feature Review Papers in Optical Sensors)
Show Figures

Figure 1

17 pages, 4616 KB  
Article
All-Metal Metamaterial-Based Sensor with Novel Geometry and Enhanced Sensing Capability at Terahertz Frequency
by Sagnik Banerjee, Ishani Ghosh, Carlo Santini, Fabio Mangini, Rocco Citroni and Fabrizio Frezza
Sensors 2025, 25(2), 507; https://doi.org/10.3390/s25020507 - 16 Jan 2025
Cited by 19 | Viewed by 3768
Abstract
This research proposes an all-metal metamaterial-based absorber with a novel geometry capable of refractive index sensing in the terahertz (THz) range. The structure consists of four concentric diamond-shaped gold resonators on the top of a gold metal plate; the resonators increase in height [...] Read more.
This research proposes an all-metal metamaterial-based absorber with a novel geometry capable of refractive index sensing in the terahertz (THz) range. The structure consists of four concentric diamond-shaped gold resonators on the top of a gold metal plate; the resonators increase in height by 2 µm moving from the outer to the inner resonators, making the design distinctive. This novel configuration has played a very significant role in achieving multiple ultra-narrow resonant absorption peaks that produce very high sensitivity when employed as a refractive index sensor. Numerical simulations demonstrate that it can achieve six significant ultra-narrow absorption peaks within the frequency range of 5 to 8 THz. The sensor has a maximum absorptivity of 99.98% at 6.97 THz. The proposed absorber also produces very high-quality factors at each resonance. The average sensitivity is 7.57/Refractive Index Unit (THz/RIU), which is significantly high when compared to the current state of the art. This high sensitivity is instrumental in detecting smaller traces of samples that have very correlated refractive indices, like several harmful gases. Hence, the proposed metamaterial-based sensor can be used as a potential gas detector at terahertz frequency. Furthermore, the structure proves to be polarization-insensitive and produces a stable absorption response when the angle of incidence is increased up to 60°. At terahertz wavelength, the proposed design can be used for any value of the aforementioned angles, targeting THz spectroscopy-based biomolecular fingerprint detection and energy harvesting applications. Full article
(This article belongs to the Special Issue Recent Advances in THz Sensing and Imaging)
Show Figures

Figure 1

10 pages, 6251 KB  
Article
Wavelength Tuning in Resonant Cavity Interband Cascade Light Emitting Diodes (RCICLEDs) via Post Growth Cavity Length Adjustment
by Nicolas Schäfer, Robert Weih, Julian Scheuermann, Florian Rothmayr, Johannes Koeth and Sven Höfling
Sensors 2024, 24(12), 3843; https://doi.org/10.3390/s24123843 - 14 Jun 2024
Cited by 3 | Viewed by 2743
Abstract
We demonstrate substrate-emitting resonant cavity interband cascade light emitting diodes (RCICLEDs) based on a single distributed Bragg reflector (DBR). These devices operate in continuous wave mode at room temperature. Compared to standard ICLEDs without a cavity, we achieved an 89% reduction in the [...] Read more.
We demonstrate substrate-emitting resonant cavity interband cascade light emitting diodes (RCICLEDs) based on a single distributed Bragg reflector (DBR). These devices operate in continuous wave mode at room temperature. Compared to standard ICLEDs without a cavity, we achieved an 89% reduction in the emission spectrum width, as indicated by the Full Width Half Maximum (FWHM) of 70 nm. Furthermore, we observed far-field narrowing and improved thermal stability. A single DBR configuration allows the cavity length to be adjusted by adding refractive index-matched material to the top of the epitaxial structure after epitaxial growth. This modification effectively shifts the cavity response towards longer wavelengths. We fabricated emitters comprising two cavities of different lengths, resulting in the emission of two distinct spectral lines that can be independently controlled. This dual-color capability enables one of the emission lines to serve as a built-in reference channel, making these LEDs highly suitable for cost-effective gas-sensing applications. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

12 pages, 2450 KB  
Article
Loop-Terminated Mach–Zehnder Interferometer Integrated with Functional Polymer for CO2 Gas Sensing
by Muhammad A. Butt
Appl. Sci. 2024, 14(11), 4714; https://doi.org/10.3390/app14114714 - 30 May 2024
Cited by 20 | Viewed by 2557
Abstract
In this work, a numerical study on the loop-terminated Mach–Zehnder interferometer (LT-MZI) structure for CO2 gas sensing applications is carried out via the finite element method. The sensing arm is covered with a polyhexamethylene biguanide (PHMB) polymer which is highly receptive to [...] Read more.
In this work, a numerical study on the loop-terminated Mach–Zehnder interferometer (LT-MZI) structure for CO2 gas sensing applications is carried out via the finite element method. The sensing arm is covered with a polyhexamethylene biguanide (PHMB) polymer which is highly receptive to CO2 gas. The refractive index of the host material decreases due to the absorption of the CO2 gas resulting in a shift in the interference pattern of the LT-MZI structure. As a result, a redshift in the wavelength is observed in the transmission spectrum of the device. The sensitivity of the device is estimated at 7.63 pm/ppm, 34.46 pm/ppm, and 74.78 pm/ppm for the sensing arm lengths of 5 µm, 10 µm, and 15 µm, respectively. The sensitivity can be further enhanced, however, at the cost of the bigger footprint of the device. Utilizing the innovative sensor design, a comprehensive range of CO2 gas concentrations spanning from 0 to 524 ppm is effectively detected. This compact and highly sensitive device serves as a vital tool for monitoring indoor CO2 levels, fostering a healthier breathing environment for all occupants. Full article
(This article belongs to the Special Issue Advanced Research in Optical Waveguides)
Show Figures

Figure 1

Back to TopTop