Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (791)

Search Parameters:
Keywords = photoacoustic

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
24 pages, 3788 KiB  
Review
Advances in Photoacoustic Imaging of Breast Cancer
by Yang Wu, Keer Huang, Guoxiong Chen and Li Lin
Sensors 2025, 25(15), 4812; https://doi.org/10.3390/s25154812 - 5 Aug 2025
Abstract
Breast cancer is the leading cause of cancer-related mortality among women world-wide, and early screening is critical for improving patient survival. Medical imaging plays a central role in breast cancer screening, diagnosis, and treatment monitoring. However, conventional imaging modalities—including mammography, ultrasound, and magnetic [...] Read more.
Breast cancer is the leading cause of cancer-related mortality among women world-wide, and early screening is critical for improving patient survival. Medical imaging plays a central role in breast cancer screening, diagnosis, and treatment monitoring. However, conventional imaging modalities—including mammography, ultrasound, and magnetic resonance imaging—face limitations such as low diagnostic specificity, relatively slow imaging speed, ionizing radiation exposure, and dependence on exogenous contrast agents. Photoacoustic imaging (PAI), a novel hybrid imaging technique that combines optical contrast with ultrasonic spatial resolution, has shown great promise in addressing these challenges. By revealing anatomical, functional, and molecular features of the breast tumor microenvironment, PAI offers high spatial resolution, rapid imaging, and minimal operator dependence. This review outlines the fundamental principles of PAI and systematically examines recent advances in its application to breast cancer screening, diagnosis, and therapeutic evaluation. Furthermore, we discuss the translational potential of PAI as an emerging breast imaging modality, complementing existing clinical techniques. Full article
(This article belongs to the Special Issue Optical Imaging for Medical Applications)
Show Figures

Figure 1

25 pages, 5899 KiB  
Review
Non-Invasive Medical Imaging in the Evaluation of Composite Scaffolds in Tissue Engineering: Methods, Challenges, and Future Directions
by Samira Farjaminejad, Rosana Farjaminejad, Pedram Sotoudehbagha and Mehdi Razavi
J. Compos. Sci. 2025, 9(8), 400; https://doi.org/10.3390/jcs9080400 - 1 Aug 2025
Viewed by 315
Abstract
Tissue-engineered scaffolds, particularly composite scaffolds composed of polymers combined with ceramics, bioactive glasses, or nanomaterials, play a vital role in regenerative medicine by providing structural and biological support for tissue repair. As scaffold designs grow increasingly complex, the need for non-invasive imaging modalities [...] Read more.
Tissue-engineered scaffolds, particularly composite scaffolds composed of polymers combined with ceramics, bioactive glasses, or nanomaterials, play a vital role in regenerative medicine by providing structural and biological support for tissue repair. As scaffold designs grow increasingly complex, the need for non-invasive imaging modalities capable of monitoring scaffold integration, degradation, and tissue regeneration in real-time has become critical. This review summarizes current non-invasive imaging techniques used to evaluate tissue-engineered constructs, including optical methods such as near-infrared fluorescence imaging (NIR), optical coherence tomography (OCT), and photoacoustic imaging (PAI); magnetic resonance imaging (MRI); X-ray-based approaches like computed tomography (CT); and ultrasound-based modalities. It discusses the unique advantages and limitations of each modality. Finally, the review identifies major challenges—including limited imaging depth, resolution trade-offs, and regulatory hurdles—and proposes future directions to enhance translational readiness and clinical adoption of imaging-guided tissue engineering (TE). Emerging prospects such as multimodal platforms and artificial intelligence (AI) assisted image analysis hold promise for improving precision, scalability, and clinical relevance in scaffold monitoring. Full article
(This article belongs to the Special Issue Sustainable Biocomposites, 3rd Edition)
Show Figures

Figure 1

10 pages, 1468 KiB  
Article
Noninvasive Mapping of Extracellular Potassium in Breast Tumors via Multi-Wavelength Photoacoustic Imaging
by Jeff Folz, Ahmad Eido, Maria E. Gonzalez, Roberta Caruso, Xueding Wang, Celina G. Kleer and Janggun Jo
Sensors 2025, 25(15), 4724; https://doi.org/10.3390/s25154724 - 31 Jul 2025
Viewed by 226
Abstract
Elevated extracellular potassium (K+) in the tumor microenvironment (TME) of breast and other cancers is increasingly recognized as a critical factor influencing tumor progression and immune suppression. Current methods for noninvasive mapping of the potassium distribution in tumors are limited. Here, [...] Read more.
Elevated extracellular potassium (K+) in the tumor microenvironment (TME) of breast and other cancers is increasingly recognized as a critical factor influencing tumor progression and immune suppression. Current methods for noninvasive mapping of the potassium distribution in tumors are limited. Here, we employed photoacoustic chemical imaging (PACI) with a solvatochromic dye-based, potassium-sensitive nanoprobe (SDKNP) to quantitatively visualize extracellular potassium levels in an orthotopic metaplastic breast cancer mouse model, Ccn6-KO. Tumors of three distinct sizes (5 mm, 10 mm, and 20 mm) were imaged using multi-wavelength photoacoustic imaging at five laser wavelengths (560, 576, 584, 605, and 625 nm). Potassium concentration maps derived from spectral unmixing of the photoacoustic images at the five laser wavelengths revealed significantly increased potassium levels in larger tumors, confirmed independently by inductively coupled plasma mass spectrometry (ICP-MS). The PACI results matched ICP-MS measurements, validating PACI as a robust, noninvasive imaging modality for potassium mapping in tumors in vivo. This work establishes PACI as a promising tool for studying the chemical properties of the TME and provides a foundation for future studies evaluating the immunotherapy response through ionic biomarker imaging. Full article
(This article belongs to the Special Issue Advances in Photoacoustic Resonators and Sensors)
Show Figures

Figure 1

12 pages, 3116 KiB  
Article
Dual-Component Beat-Frequency Quartz-Enhanced Photoacoustic Spectroscopy Gas Detection System
by Hangyu Xu, Yiwen Feng, Zihao Chen, Zhenzhao Zhuang, Jinbao Xia, Yiyang Zhao and Sasa Zhang
Photonics 2025, 12(8), 747; https://doi.org/10.3390/photonics12080747 - 24 Jul 2025
Viewed by 248
Abstract
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting [...] Read more.
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting the transient response of the quartz tuning fork (QTF) to acquire gas concentrations while concurrently capturing the QTF resonant frequency and quality factor in real-time. Owing to the short beat period and rapid system response, this approach significantly reduces time-delay constraints in time-division measurements, eliminating the need for periodic calibration inherent in conventional methods and preventing detection interruptions. The experimental results demonstrate minimum detection limits of 5.69 ppm for methane and 0.60 ppm for acetylene. Both gases exhibited excellent linear responses over the concentration range of 200 ppm to 4000 ppm, with the R2 value for methane being 0.996 and for acetylene being 0.997. The system presents a viable solution for the real-time, calibration-free monitoring of dissolved gases in transformer oil. Full article
(This article belongs to the Special Issue Advances in Optical Fiber Sensing Technology)
Show Figures

Figure 1

23 pages, 4894 KiB  
Article
Evaluating Copper-Induced Oxidative Stress in Germinating Wheat Seeds Using Laser Photoacoustic Spectroscopy and EPR Techniques
by Mioara Petrus, Cristina Popa, Ana-Maria Bratu, Alexandra Camelia Joita and Vasile Bercu
Toxics 2025, 13(7), 604; https://doi.org/10.3390/toxics13070604 - 18 Jul 2025
Viewed by 392
Abstract
Copper is an essential micronutrient for plants, but excessive levels can induce toxicity and impair physiological functions. This study evaluates the toxic effects of copper sulfate (CuSO4) on the germination of common wheat (Triticum aestivum), with emphasis on the [...] Read more.
Copper is an essential micronutrient for plants, but excessive levels can induce toxicity and impair physiological functions. This study evaluates the toxic effects of copper sulfate (CuSO4) on the germination of common wheat (Triticum aestivum), with emphasis on the gas emission dynamics and oxidative stress biomarkers. Seeds were germinated in agar and exposed to CuSO4 at concentrations of 1 µM, 100 µM, 1 mM, and 10 mM; distilled water served as the control. Ethylene and ammonia emissions were quantified using CO2 laser photoacoustic spectroscopy, while electron paramagnetic resonance (EPR) spectroscopy was employed to detect free radicals and Cu2+ complexes. Exposure to Cu concentrations ≥ 1 mM significantly inhibited germination and biomass accumulation. Enhanced ethylene and ammonia emissions, particularly at 10 mM, indicated stress-related metabolic responses. The EPR spectra confirmed the presence of semiquinone radicals and Cu2+ complexes under higher Cu levels. These results demonstrate that photoacoustic and EPR techniques are effective tools for the early detection of metal-induced phytotoxicity and offer a non-invasive approach to environmental toxicity screening and plant stress assessment. Full article
Show Figures

Graphical abstract

18 pages, 2083 KiB  
Article
Quantification of Microplastics in Urban Compost-Amended Farmland Soil Using an Elutriation Device
by Luigi Paolo D’Acqui, Sara Di Lonardo, Martina Grattacaso, Alessandra Bonetti and Ottorino-Luca Pantani
Agronomy 2025, 15(7), 1736; https://doi.org/10.3390/agronomy15071736 - 18 Jul 2025
Viewed by 228
Abstract
Microplastics (MPs) present in farmland soils, where urban compost has been distributed since 2005, were extracted using a device based on elutriation, a method developed for marine sediments but not yet used in soil. Since (i) fine earth (diameter < 2 mm) is [...] Read more.
Microplastics (MPs) present in farmland soils, where urban compost has been distributed since 2005, were extracted using a device based on elutriation, a method developed for marine sediments but not yet used in soil. Since (i) fine earth (diameter < 2 mm) is the standard fraction used for soil analysis and (ii) the size of MPs contained in urban compost may exceed that value, MP were recovered from both the entire soil and fine earth. The recovered MPs pieces were weighed, counted, and characterized using FTIR photoacoustic spectroscopy (FTIR-PAS). Both the mass and number of recovered MPs pieces (>34 µm) were comparable to those reported in the literature for soils. Polystyrene, polyethylene, and polypropylene are the primary polymers. Nevertheless, some issues were highlighted: (i) the importance of sampling the soil by volume, and (ii) the need of analyzing the entire soil sample rather than just the fraction below 2 mm, commonly used in soil analysis; (iii) the necessity of breaking up (i.e., by ultrasonication and/or dispersion) soil aggregates that may withstand the elutriation process. Full article
(This article belongs to the Section Agroecology Innovation: Achieving System Resilience)
Show Figures

Figure 1

10 pages, 1296 KiB  
Article
High-Sensitivity Dynamic Detection of Dissolved Acetylene in Transformer Oil Based on High-Power Quartz-Enhanced Photoacoustic Spectroscopy Sensing System
by Yuxiang Wu, Tiehua Ma, Chenhua Liu, Yashan Fan, Shuai Shi, Songjie Guo, Yu Wang, Xiangjun Xu, Guqing Guo, Xuanbing Qiu, Zhijin Shang and Chuanliang Li
Photonics 2025, 12(7), 713; https://doi.org/10.3390/photonics12070713 - 16 Jul 2025
Viewed by 281
Abstract
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with [...] Read more.
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with an optimized acoustic resonator to enhance the acoustic signal. The laser power was boosted to 150 mW using a C-band erbium-doped fiber amplifier (EDFA), achieving a detection limit of 469 ppb for C2H2 with an integration time of 1 s. The headspace degassing method was utilized to extract dissolved gases from the transformer oil, and the equilibrium process for the release of dissolved C2H2 was successfully monitored using the developed high-power QEPAS system. This approach provides reliable technical support for the real-time monitoring of the operational safety of power transformers. Full article
(This article belongs to the Section Lasers, Light Sources and Sensors)
Show Figures

Figure 1

26 pages, 1906 KiB  
Article
The Thermoelastic Component of the Photoacoustic Response in a 3D-Printed Polyamide Coated with Pigment Dye: A Two-Layer Model Incorporating Fractional Heat Conduction Theories
by Marica N. Popovic, Slobodanka P. Galovic, Ervin K. Lenzi and Aloisi Somer
Fractal Fract. 2025, 9(7), 456; https://doi.org/10.3390/fractalfract9070456 - 12 Jul 2025
Viewed by 237
Abstract
This study presents a theoretical model for the thermoelastic response in transmission-mode photoacoustic systems that feature a two-layer structure. The model incorporates volumetric optical absorption in both layers and is based on classical heat conduction theory, hyperbolic generalized heat conduction theory, and fractional [...] Read more.
This study presents a theoretical model for the thermoelastic response in transmission-mode photoacoustic systems that feature a two-layer structure. The model incorporates volumetric optical absorption in both layers and is based on classical heat conduction theory, hyperbolic generalized heat conduction theory, and fractional heat conduction models including inertial memory in Generalizations of the Cattaneo Equation (GCEI, GCEII, and GCEIII). To validate the model, comparisons were made with the existing literature models. Using the proposed model, the thermoelastic photoacoustic response of a two-layer system composed of a 3D-printed porous polyamide (PA12) substrate coated with a thin, highly absorptive protective dye layer is analyzed. We obtain that the thickness and thermal conduction in properties of the coating are very important in influencing the thermoelastic component and should not be overlooked. Furthermore, the thermoelastic component is affected by the selected fractional model—whether it is subdiffusion or superdiffusion—along with the value of the order of the fractional derivative, as well as the optical absorption coefficient of the layer being investigated. Additionally, it is concluded that the phase has a greater impact than the amplitude when selecting the appropriate theoretical heat conduction model. Full article
Show Figures

Figure 1

35 pages, 9604 KiB  
Review
Multifunctional Upconversion Nanoparticles Transforming Photoacoustic Imaging: A Review
by Yuqian Zhang, Zerui Li, Ziqing Du, Jianming Pan and Yanan Huang
Nanomaterials 2025, 15(14), 1074; https://doi.org/10.3390/nano15141074 - 10 Jul 2025
Viewed by 645
Abstract
Photoacoustic imaging (PAI) merges the high spatial resolution of optical methods with the deep tissue penetration provided by ultrasound, making it a valuable tool in biomedical imaging. In recent years, a diverse array of photoacoustic contrast agents, spanning both organic and inorganic materials, [...] Read more.
Photoacoustic imaging (PAI) merges the high spatial resolution of optical methods with the deep tissue penetration provided by ultrasound, making it a valuable tool in biomedical imaging. In recent years, a diverse array of photoacoustic contrast agents, spanning both organic and inorganic materials, has been developed. Among them, upconversion nanoparticles (UCNPs) stand out as promising candidates due to their unique optical features, tunable absorption in the near-infrared I (NIR-I, 750–1350 nm) region, and strong potential for both imaging and treatment-related uses. This review discusses the growing significance of UCNPs in the field of PAI, focusing on their structural characteristics, strengths, and existing challenges. Then, we talk about an up-to-date account of the current literature on the use of UCNPs as contrast agents for PAI. Lastly, we discuss the challenges and perspectives of UCNPs as a contrast agent for PAI in preclinical research and clinical diagnosis. Full article
Show Figures

Figure 1

27 pages, 5697 KiB  
Review
Optical Non-Invasive Glucose Monitoring Using Aqueous Humor: A Review
by Haolan Xi and Yiqing Gong
Sensors 2025, 25(13), 4236; https://doi.org/10.3390/s25134236 - 7 Jul 2025
Viewed by 778
Abstract
This review explores optical technologies for non-invasive glucose monitoring (NIGM) using aqueous humor (AH) as media, addressing the limitations of traditional invasive methods in diabetes management. It analyzes key techniques such as Raman spectroscopy, polarimetry, and mid- and near-infrared spectral methods, highlighting their [...] Read more.
This review explores optical technologies for non-invasive glucose monitoring (NIGM) using aqueous humor (AH) as media, addressing the limitations of traditional invasive methods in diabetes management. It analyzes key techniques such as Raman spectroscopy, polarimetry, and mid- and near-infrared spectral methods, highlighting their respective challenges, alongside emerging hybrid approaches like photoacoustic spectroscopy and optical coherence tomography. Crucially, the practical realization of these optical methods for portable NIGM hinges on advanced instrumentation. Therefore, this review also details progress in compact NIR spectrometers. While conventional systems often lack suitability, significant advancements in on-chip technologies—including miniaturized dispersive spectrometers and various on-chip Fourier transform systems (e.g., spatial heterodyne, stationary wave integral, and temporally modulated FT systems)—utilizing integration platforms like SOI and SiN are promising. Such innovations offer the potential for high spectral resolution, large bandwidth, and miniaturization, which are essential for developing practical AH-based NIGM systems to improve diabetes care. Full article
(This article belongs to the Special Issue Advances in Miniaturization and Power Efficiency of Optical Sensors)
Show Figures

Figure 1

23 pages, 1184 KiB  
Article
Time-Resolved Photoacoustic Response of Thin Semiconductors Measured with Minimal Volume Cell: Influence of Photoinduced Charge Carriers
by Slobodanka P. Galovic, Dragana K. Markushev, Dragan D. Markushev, Katarina Lj. Djordjevic, Marica N. Popovic, Edin Suljovrujic and Dragan M. Todorovic
Appl. Sci. 2025, 15(13), 7290; https://doi.org/10.3390/app15137290 - 28 Jun 2025
Viewed by 228
Abstract
When a semiconducting sample is illuminated by an intensity-modulated monochromatic light beam with photon energy exceeding the band gap, part of the absorbed energy is directly converted into heat through photon–lattice interactions. This gives rise to a heat source that closely follows the [...] Read more.
When a semiconducting sample is illuminated by an intensity-modulated monochromatic light beam with photon energy exceeding the band gap, part of the absorbed energy is directly converted into heat through photon–lattice interactions. This gives rise to a heat source that closely follows the temporal profile of the optical excitation, known as the fast heat source. Simultaneously, another portion of the absorbed energy is used to generate electron-hole pairs. These charge carriers diffuse together and recombine via electron–electron and electron–hole interactions, transferring their kinetic energy to the lattice and producing additional heating of the sample. This indirect heating mechanism, associated with carrier recombination, is referred to as the slow heat source. In this study, we develop a model describing surface temperature variations on the non-illuminated side of a thermally thin semiconductor exposed to a rectangular optical pulse, explicitly accounting for the contribution of surface charge carrier recombinations. Using this model, we investigate the influence of surface recombination velocity and the material’s plasma properties on the time-domain temperature response for both plasma-opaque and plasma-transparent samples. Our results demonstrate that charge carrier recombinations can significantly affect the transient photoacoustic signal recorded using a minimum volume cell, highlighting the potential of time-resolved photoacoustic techniques for probing the electronic properties of semiconductors. Full article
(This article belongs to the Special Issue Advances in Photoacoustic and Photothermal Phenomena)
Show Figures

Figure 1

15 pages, 3527 KiB  
Article
Photoacoustic Spectroscopy Combined with a Multipass Circular Cell to Detect Low Concentrations of Ammonia
by Oscar E. Bonilla-Manrique, Alejandro Pérez Gonzalez-Banfi, Jorge Viñuela Pérez and Gabriele Dessena
Appl. Sci. 2025, 15(12), 6727; https://doi.org/10.3390/app15126727 - 16 Jun 2025
Viewed by 386
Abstract
Photoacoustic spectroscopy (PAS) has become a valuable technique for trace gas detection due to its high sensitivity and potential for miniaturization. This study presents the development and evaluation of a near-infrared PAS system using a 1532 nm semiconductor laser and a multipass cell [...] Read more.
Photoacoustic spectroscopy (PAS) has become a valuable technique for trace gas detection due to its high sensitivity and potential for miniaturization. This study presents the development and evaluation of a near-infrared PAS system using a 1532 nm semiconductor laser and a multipass cell (MPC) designed to enhance the optical path and thereby improve the detection of ammonia (NH3). The minimum detection limit was determined to be 770 ppb, with a normalized noise equivalent absorption (NNEA) coefficient of 1.07 × 10−8 W cm−1 Hz−1/2. While competitive with similar PAS systems, these results indicate that mid-infrared technologies still offer superior detection thresholds. The findings suggest that while this near-infrared setup may not yet match the sensitivity of systems using quantum cascade lasers or QEPAS, it offers notable advantages in terms of simplicity, cost, and potential for field deployment. The system’s configuration makes it a viable and efficient tool for industrial gas monitoring and real-time environmental applications, with future improvements likely to come from transitioning to the mid-infrared region and advancing laser stabilization and miniaturization techniques. Full article
(This article belongs to the Special Issue Recent Advances in Optical Sensors)
Show Figures

Figure 1

16 pages, 8177 KiB  
Article
Study and Characterization of Silicon Nitride Optical Waveguide Coupling with a Quartz Tuning Fork for the Development of Integrated Sensing Platforms
by Luigi Melchiorre, Ajmal Thottoli, Artem S. Vorobev, Giansergio Menduni, Angelo Sampaolo, Giovanni Magno, Liam O’Faolain and Vincenzo Spagnolo
Sensors 2025, 25(12), 3663; https://doi.org/10.3390/s25123663 - 11 Jun 2025
Viewed by 913
Abstract
This work demonstrates an ultra-compact optical gas-sensing system, consisting of a pigtailed laser diode emitting at 1392.5 nm for water vapor (H2O) detection, a silicon nitride (Si3N4) optical waveguide to guide the laser light, and a custom-designed, [...] Read more.
This work demonstrates an ultra-compact optical gas-sensing system, consisting of a pigtailed laser diode emitting at 1392.5 nm for water vapor (H2O) detection, a silicon nitride (Si3N4) optical waveguide to guide the laser light, and a custom-designed, low-frequency, and T-shaped Quartz Tuning Fork (QTF) as the sensitive element. The system employs both Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) and Light-Induced Thermoelastic Spectroscopy (LITES) techniques for trace gas sensing. A 3.8 mm-wide, S-shaped waveguide path was designed to prevent scattered laser light from directly illuminating the QTF. Both QEPAS and LITES demonstrated comparably low signal-to-noise ratios (SNRs), ranging from 1.6 to 3.2 for a 1.6% indoor H2O concentration, primarily owing to the reduced optical power (~300 μW) delivered to the QTF excitation point. These results demonstrate the feasibility of integrating photonic devices and piezoelectric components into portable gas-sensing systems for challenging environments. Full article
(This article belongs to the Special Issue Feature Papers in Optical Sensors 2025)
Show Figures

Figure 1

16 pages, 521 KiB  
Systematic Review
Antibacterial and Bactericidal Effects of the Er: YAG Laser on Oral Bacteria: A Systematic Review of Microbiological Evidence
by Jakub Fiegler-Rudol, Dariusz Skaba, Aleksandra Kawczyk-Krupka and Rafał Wiench
J. Funct. Biomater. 2025, 16(6), 209; https://doi.org/10.3390/jfb16060209 - 3 Jun 2025
Viewed by 892
Abstract
Background: The Er:YAG laser has gained attention in dentistry for its potential to enhance microbial disinfection through targeted photothermal and photoacoustic mechanisms. Objective: This systematic review aimed to evaluate the antibacterial and bactericidal efficacy of Er:YAG laser therapy across clinically relevant oral pathogens [...] Read more.
Background: The Er:YAG laser has gained attention in dentistry for its potential to enhance microbial disinfection through targeted photothermal and photoacoustic mechanisms. Objective: This systematic review aimed to evaluate the antibacterial and bactericidal efficacy of Er:YAG laser therapy across clinically relevant oral pathogens in in vitro models. Methods: Following the PRISMA 2020 guidelines, a systematic search of PubMed, Embase, Scopus, and the Cochrane Library was conducted for studies published between 2015 and 2025. The review protocol was registered with PROSPERO (CRD420251031368). Eligibility criteria included in vitro or animal studies assessing the bactericidal effects of the Er:YAG laser on oral bacteria or fungi, either alone or in combination with chemical disinfectants. Study selection, data extraction, and quality assessment were conducted independently by multiple reviewers. Results: Ten in vitro studies met inclusion criteria. The Er:YAG laser demonstrated significant antibacterial effects against Enterococcus faecalis, Streptococcus mutans, Porphyromonas gingivalis, Candida albicans, and other species. Greater bacterial reduction was consistently observed when the laser was combined with adjunctive irrigants such as sodium hypochlorite or hydrogen peroxide. The laser was effective in reducing biofilm biomass and viable counts, particularly in complex anatomical settings. Most studies were rated as low risk of bias. Conclusions: Er:YAG laser therapy is a promising adjunctive tool for microbial disinfection in dentistry, particularly in challenging anatomical sites. Further well-designed in vivo and clinical studies are needed to confirm its efficacy and determine optimal treatment parameters. Full article
(This article belongs to the Section Biomaterials and Devices for Healthcare Applications)
Show Figures

Figure 1

21 pages, 2012 KiB  
Article
A Synergistic Approach Using Photoacoustic Spectroscopy and AI-Based Image Analysis for Post-Harvest Quality Assessment of Conference Pears
by Mioara Petrus, Cristina Popa, Ana Maria Bratu, Vasile Bercu, Leonard Gebac, Delia-Mihaela Mihai, Ana-Cornelia Butcaru, Florin Stanica and Ruxandra Gogot
Molecules 2025, 30(11), 2431; https://doi.org/10.3390/molecules30112431 - 1 Jun 2025
Cited by 1 | Viewed by 559
Abstract
This study presents a non-invasive approach to monitoring post-harvest fruit quality by applying CO2 laser photoacoustic spectroscopy (CO2LPAS) to study the respiration of “Conference” pears from local and commercially stored (supermarket) sources. Concentrations of ethylene (C2H4), [...] Read more.
This study presents a non-invasive approach to monitoring post-harvest fruit quality by applying CO2 laser photoacoustic spectroscopy (CO2LPAS) to study the respiration of “Conference” pears from local and commercially stored (supermarket) sources. Concentrations of ethylene (C2H4), ethanol (C2H6O), and ammonia (NH3) were continuously monitored under shelf-life conditions. Our results reveal that ethylene emission peaks earlier in supermarket pears, likely due to post-harvest treatments, while ethanol accumulates over time, indicating fermentation-related deterioration. Significantly, ammonia levels increased during the late stages of senescence, suggesting its potential role as a novel biomarker for fruit degradation. The application of CO2LPAS enabled highly sensitive, real-time detection of trace gases without damaging the fruit, offering a powerful alternative to traditional monitoring methods. Additionally, artificial intelligence (AI) models, particularly convolutional neural networks (CNNs), were explored to enhance data interpretation, enabling early detection of ripening and spoilage patterns through volatile compound profiling. This study advances our understanding of post-harvest physiological processes and proposes new strategies for improving storage and distribution practices for climacteric fruits. Full article
(This article belongs to the Special Issue Exclusive Feature Papers in Physical Chemistry, 3nd Edition)
Show Figures

Graphical abstract

Back to TopTop