Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (783)

Search Parameters:
Keywords = muscle ultrasound

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 2779 KiB  
Article
Clinical and Electrodiagnostic Correlations of Ultrasound-Detected Markedly Enlarged Median Nerve at the Wrist
by Lisa B. E. Shields, Vasudeva G. Iyer, Theresa Kluthe, Kahir Jawad, Jun Cai, Yi Ping Zhang and Christopher B. Shields
Neurol. Int. 2025, 17(8), 124; https://doi.org/10.3390/neurolint17080124 - 7 Aug 2025
Abstract
Background/Objectives: This is a retrospective review of 36 patients with electrodiagnostic (EDX) confirmation of carpal tunnel syndrome (CTS) and ultrasound (US) detection of marked median nerve enlargement (defined as a cross-sectional area [CSA] of 40 mm2 or greater) at the wrist. Methods: [...] Read more.
Background/Objectives: This is a retrospective review of 36 patients with electrodiagnostic (EDX) confirmation of carpal tunnel syndrome (CTS) and ultrasound (US) detection of marked median nerve enlargement (defined as a cross-sectional area [CSA] of 40 mm2 or greater) at the wrist. Methods: We describe the clinical, electrodiagnostic (EDX), and US findings in these patients and discuss the pathophysiologic basis of a markedly enlarged median nerve. Results: The markedly enlarged median nerve was detected by US in a total of 39 hands (36 patients, with 3 bilateral). Of the 39 hands, thenar atrophy was observed in 15 (38.5%) hands, and pinprick loss in the median nerve distribution was noted in all hands. Moderately severe or severe median nerve entrapment at the carpal tunnel (CT) was confirmed by EDX studies in 21 (53.8%) and 16 (41.0%) hands, respectively. A total of 12 (30.8%) hands had no compound muscle action potentials (CMAPs) over the abductor pollicis brevis muscle, and sensory nerve action potentials (SNAPs) were not detected in 31 (79.5%) hands. The wrist CSA was between 40 and 44 mm2 in 20 (51.3%) hands, between 45 and 49 mm2 in 13 (33.3%) hands, and 50 mm2 or greater in 6 (15.4%) hands. Conclusions: The implications of the markedly enlarged median nerve for surgical management of CTS are unknown, and future prospective studies are needed. Full article
(This article belongs to the Section Movement Disorders and Neurodegenerative Diseases)
Show Figures

Figure 1

15 pages, 3059 KiB  
Article
The Sonographic Evaluation of Abductor Injury After Intramedullary Nailing for the Hip Fractures
by Yonghyun Yoon, Howon Lee, King Hei Stanley Lam, Minjae Lee, Jonghyeok Lee and Jihyo Hwang
J. Clin. Med. 2025, 14(15), 5498; https://doi.org/10.3390/jcm14155498 - 5 Aug 2025
Abstract
Background/Objectives: Iatrogenic abductor muscle injury following intramedullary nailing for proximal hip fractures can negatively impact postoperative rehabilitation and clinical outcomes. To quantify iatrogenic abductor muscle injury after intramedullary nailing and detect the degree of degenerative change in muscle around the entry point of [...] Read more.
Background/Objectives: Iatrogenic abductor muscle injury following intramedullary nailing for proximal hip fractures can negatively impact postoperative rehabilitation and clinical outcomes. To quantify iatrogenic abductor muscle injury after intramedullary nailing and detect the degree of degenerative change in muscle around the entry point of trochanteric fractures. Methods: This cross-sectional study used data from a single center database from May to December 2023. This study utilized ultrasound examinations performed by a single expert orthopedic surgeon. This study included 61 patients who underwent intramedullary nailing surgery for adult hip fractures. All surgeries were performed by a single experienced hip surgeon. Patients who declined sonographic evaluation or did not undergo ultrasound during their admission were excluded. For more accurate comparison, sonography was also conducted on the healthy, non-operative limb. Descriptive statistics were used to summarize patient and ultrasound findings. A subgroup analysis using Fisher’s exact test was performed to assess the association between implant type and the incidence of iatrogenic gluteus medius tendon injury. Results: Of the 61 patients, tendon tears were identified in 35 cases (57%) on the affected side, with 20 cases (33%) involving gluteus medius tendon tears without fractures on the ipsilateral facet. Gluteus minimus tendon tears were observed in 13 cases (21%), while gluteus medius tendon tears were noted in 31 cases (51%). In the unaffected limbs, tendon degeneration was detected in the form of tendinosis and calcification. Overall, 39 patients (64%) exhibited abductor tendon tendinosis, and 30 patients (49%) were diagnosed with calcification. Conclusions: Gluteus medius and Gluteus minimus are important abductors for hip disease rehabilitation. Iatrogenic gluteus medius tendon injury during the intramedullary nailing showed 33%. Abductor degeneration also showed 92% of the unaffected limbs. This study suggests that abductor degeneration can be a risk factor of falling among the elderly population and an iatrogenic abductor injury can be an obstacle for the early recovery of ambulation in the hip fracture patients. Prevention of abductor degeneration and iatrogenic abductor injury might be important for the hip fracture prevention and rehabilitation. Full article
(This article belongs to the Section Orthopedics)
Show Figures

Figure 1

15 pages, 1306 KiB  
Article
Measurement Reliability for the Anatomical Characteristics of Cervical Muscles Using Musculoskeletal Ultrasound in Healthy Individuals
by Georgios Sidiropoulos, Nikolaos Strimpakos, Asimakis K. Kanellopoulos, Maria Tsekoura, Konstantinos Alexiou, Olympia Papakonstantinou and Zacharias Dimitriadis
Muscles 2025, 4(3), 28; https://doi.org/10.3390/muscles4030028 - 5 Aug 2025
Viewed by 66
Abstract
Background: The reliable assessment of cervical muscle morphology is essential for both clinical and research use. However, evidence on the reliability of ultrasound measurements remains limited. Objective: To investigate the intra-rater and test–retest reliability of morphological measurements of the Longus Colli, Sternocleidomastoid, Multifidus [...] Read more.
Background: The reliable assessment of cervical muscle morphology is essential for both clinical and research use. However, evidence on the reliability of ultrasound measurements remains limited. Objective: To investigate the intra-rater and test–retest reliability of morphological measurements of the Longus Colli, Sternocleidomastoid, Multifidus Cervicis, and Semispinalis Capitis muscles using musculoskeletal ultrasound. Methods: Cross-sectional area, anteroposterior, and lateral dimensions were assessed using B-mode ultrasound. Anterior neck muscles were scanned in the supine position, while posterior neck muscles were scanned in the prone position. Each muscle was measured three times (to assess intra-rater reliability), which was repeated after 30 min (to assess test–retest reliability). Measurements were also normalized according to BMI and neck circumference. Results: Intra-rater reliability was found to be good to excellent for the Longus Colli (ICC = 0.77–0.92), excellent for the Sternocleidomastoid (ICC = 0.93–0.99), good to excellent for the Semispinalis Capitis (ICC = 0.89–0.97), and moderate to excellent for the Multifidus Cervicis (ICC = 0.69–0.92). Test–retest reliability was found to be moderate to good for the Longus Colli (ICC = 0.73–0.87), good to excellent for the Sternocleidomastoid (ICC = 0.84–0.98), good to excellent for the Semispinalis Capitis (ICC = 0.78–0.95), and good to excellent for the Multifidus Cervicis (ICC = 0.80–0.92). Conclusions: Musculoskeletal ultrasound demonstrates strong reliability for cervical muscle assessment, supporting its clinical use. Full article
Show Figures

Figure 1

13 pages, 849 KiB  
Article
Morphofunctional Profile Focusing on Strength and Ultrasound of the Upper Limbs in Female Breast Cancer Survivors: A Comparative Cross-Sectional Study Between Groups with and Without Lymphoedema and Between Ipsilateral and Contralateral Limbs
by Ana Rafaela Cardozo Da Silva, Juliana Netto Maia, Vanessa Maria Da Silva Alves Gomes, Naiany Tenório, Juliana Fernandes de Souza Barbosa, Ana Claudia Souza da Silva, Vanessa Patrícia Soares de Sousa, Leila Maria Alvares Barbosa, Armèle de Fátima Dornelas de Andrade and Diego Dantas
Biomedicines 2025, 13(8), 1884; https://doi.org/10.3390/biomedicines13081884 - 2 Aug 2025
Viewed by 300
Abstract
Background: Breast cancer is the most common neoplasm in women. Despite effective treatments, sequelae such as decreased muscle strength, upper limb dysfunction, and tissue changes are common, highlighting the need for functional assessments during rehabilitation. This study analysed the morphofunctional profile of [...] Read more.
Background: Breast cancer is the most common neoplasm in women. Despite effective treatments, sequelae such as decreased muscle strength, upper limb dysfunction, and tissue changes are common, highlighting the need for functional assessments during rehabilitation. This study analysed the morphofunctional profile of the upper limbs in breast cancer survivors, comparing muscle strength and ultrasound findings between groups with and without lymphoedema, as well as between ipsilateral and contralateral limbs. Methods: This cross-sectional study included female breast cancer survivors treated at an oncology physical therapy clinic. Muscle strength was measured using dynamometry (handgrip and arm flexor strength), and ultrasound assessed the thickness of the dermal–epidermal complex (DEC), subcutaneous tissue (SUB), and muscle (MT). Results: The upper limbs of 41 women were evaluated. No significant differences were observed between those with and without breast cancer-related lymphoedema (BCRL). When comparing the ipsilateral and contralateral limbs, significant reductions were observed in arm flexor strength (p < 0.001; 95% CI: −9.77 to −2.50), handgrip strength (p < 0.001; 95% CI: −4.10 to −1.22), and tissue thickness, with increased DEC thickness on the forearm (0.20 mm; p = 0.022) and arm flexors (0.25 mm; p < 0.001) of the ipsilateral limb. Conclusion: Significant differences in muscle strength and tissue structure between ipsilateral and contralateral limbs may reflect surgical and local pathophysiological effects. A trend toward reduced values for these parameters was also noted in limbs with BCRL, reinforcing the importance of future research to elucidate underlying mechanisms and guide more effective therapeutic strategies. Full article
(This article belongs to the Section Molecular and Translational Medicine)
Show Figures

Figure 1

14 pages, 1227 KiB  
Article
Reliability and Inter-Device Agreement Between a Portable Handheld Ultrasound Scanner and a Conventional Ultrasound System for Assessing the Thickness of the Rectus Femoris and Vastus Intermedius
by Carlante Emerson, Hyun K. Kim, Brian A. Irving and Efthymios Papadopoulos
J. Funct. Morphol. Kinesiol. 2025, 10(3), 299; https://doi.org/10.3390/jfmk10030299 - 1 Aug 2025
Viewed by 125
Abstract
Background: Ultrasound (U/S) can be used to evaluate skeletal muscle characteristics in clinical and sports settings. Handheld U/S devices have recently emerged as a cheaper and portable alternative to conventional U/S systems. However, further research is warranted on their reliability. We assessed [...] Read more.
Background: Ultrasound (U/S) can be used to evaluate skeletal muscle characteristics in clinical and sports settings. Handheld U/S devices have recently emerged as a cheaper and portable alternative to conventional U/S systems. However, further research is warranted on their reliability. We assessed the reliability and inter-device agreement between a handheld U/S device (Clarius L15 HD3) and a more conventional U/S system (GE LOGIQ e) for measuring the thickness of the rectus femoris (RF) and vastus intermedius (VI). Methods: Cross-sectional images of the RF and VI muscles were obtained in 20 participants by two assessors, and on two separate occasions by one of those assessors, using the Clarius L15 HD3 and GE LOGIQ e devices. RF and VI thickness measurements were obtained to determine the intra-rater reliability, inter-rater reliability, and inter-device agreement. Results: All intraclass correlation coefficients (ICCs) were above 0.9 for intra-rater reliability (range: 0.94 to 0.97), inter-rater reliability (ICC: 0.97), and inter-device agreement (ICC: 0.98) when comparing the two devices in assessing RF and VI thickness. For the RF, the Bland–Altman plot revealed a mean difference of 0.06 ± 0.07 cm, with limits of agreement ranging from 0.21 to −0.09, whereas for the VI, the Bland–Altman plot showed a mean difference of 0.07 ± 0.10 cm, with limits of agreement ranging from 0.27 to −0.13. Conclusions: The handheld Clarius L15 HD3 was reliable and demonstrated high agreement with the more conventional GE LOGIQ e for assessing the thickness of the RF and VI in young, healthy adults. Full article
(This article belongs to the Section Kinesiology and Biomechanics)
Show Figures

Figure 1

12 pages, 441 KiB  
Article
Diagnostic Value of Point-of-Care Ultrasound for Sarcopenia in Geriatric Patients Hospitalized for Hip Fracture
by Laure Mondo, Chloé Louis, Hinda Saboul, Laetitia Beernaert and Sandra De Breucker
J. Clin. Med. 2025, 14(15), 5424; https://doi.org/10.3390/jcm14155424 - 1 Aug 2025
Viewed by 234
Abstract
Introduction: Sarcopenia is a systemic condition linked to increased morbidity and mortality in older adults. Point-of-Care Ultrasound (POCUS) offers a rapid, bedside method to assess muscle mass. This study evaluates the diagnostic accuracy of POCUS compared to Dual-energy X-ray Absorptiometry (DXA), the [...] Read more.
Introduction: Sarcopenia is a systemic condition linked to increased morbidity and mortality in older adults. Point-of-Care Ultrasound (POCUS) offers a rapid, bedside method to assess muscle mass. This study evaluates the diagnostic accuracy of POCUS compared to Dual-energy X-ray Absorptiometry (DXA), the gold standard method, and explores its prognostic value in old patients undergoing surgery for hip fractures. Patients and Methods: In this prospective, single-center study, 126 patients aged ≥ 70 years and hospitalized with hip fractures were included. Sarcopenia was defined according to the revised 2018 EWGSOP2 criteria. Muscle mass was assessed by the Appendicular Skeletal Muscle Mass Index (ASMI) using DXA and by the thickness of the rectus femoris (RF) muscle using POCUS. Results: Of the 126 included patients, 52 had both DXA and POCUS assessments, and 43% of them met the diagnostic criteria for sarcopenia or severe sarcopenia. RF muscle thickness measured by POCUS was significantly associated with ASMI (R2 = 0.30; p < 0.001). POCUS showed a fair diagnostic accuracy in women (AUC 0.652) and an excellent accuracy in men (AUC 0.905). Optimal diagnostic thresholds according to Youden’s index were 5.7 mm for women and 9.3 mm for men. Neither RF thickness, ASMI, nor sarcopenia status predicted mortality or major postoperative complications. Conclusions: POCUS is a promising, accessible tool for diagnosing sarcopenia in old adults with hip fractures. Nonetheless, its prognostic utility remains uncertain and should be further evaluated in long-term studies. Full article
(This article belongs to the Special Issue The “Orthogeriatric Fracture Syndrome”—Issues and Perspectives)
Show Figures

Figure 1

21 pages, 1893 KiB  
Article
Relationship Between Body Composition and Biomarkers in Adult Females with Breast Cancer: 1-Year Follow-Up Prospective Study
by Angélica Larrad-Sáinz, María Gemma Hernández Núñez, Ana Barabash Bustelo, Inés Gil Prados, Johanna Valerio, José Luis Espadas Gil, María Eugenia Olivares Crespo, María Herrera de la Muela, Blanca Bernaldo Madrid, Irene Serrano García, Ignacio Cristóbal García, Miguel Ángel Rubio-Herrera, Alfonso Luis Calle-Pascual, Juana María Brenes Sánchez and Pilar Matía-Martín
Nutrients 2025, 17(15), 2487; https://doi.org/10.3390/nu17152487 - 30 Jul 2025
Viewed by 269
Abstract
Background/Objectives: After diagnosis, it is common for women with breast cancer to gain weight, which is associated with worse clinical outcomes. However, traditional measures such as body weight, BMI, and waist circumference do not detect key changes in body composition, such as fat [...] Read more.
Background/Objectives: After diagnosis, it is common for women with breast cancer to gain weight, which is associated with worse clinical outcomes. However, traditional measures such as body weight, BMI, and waist circumference do not detect key changes in body composition, such as fat redistribution or muscle loss. The objective of this exploratory study was to assess the evolution of body composition and muscle strength after one year of treatment, and their relationship with metabolic biomarkers. Methods: Prospective observational study in newly diagnosed breast cancer patients. Body composition was assessed using bioelectrical impedance analysis (BIA) and ultrasound (US); muscle strength was measured by handgrip dynamometry. Biomarkers analyzed included glucose, insulin, Homeostatic Model Assessment of Insulin Resistance (HOMA-IR), glycosylated hemoglobin (HbA1c), total cholesterol (and its fractions), triglycerides, C-reactive protein (CRP), 6-interleukin (IL-6), vitamin D, myostatin, and fibroblast growth factor 21 (FGF-21). Results: Sixty-one women (mean age 58 years) were included. After one year, fat mass and related parameters significantly increased, while skeletal muscle mass and muscle strength decreased. Sarcopenic obesity prevalence rose from 1.16% to 4.9%. No significant changes were found in biomarkers, but positive correlations were observed between fat parameters and insulin, HOMA-IR, and triglycerides, and negative correlations with HDL-cholesterol. Conclusions: BIA and US can detect unfavorable changes in body composition that are not reflected in conventional measurements. At one year post-diagnosis, women showed increased fat accumulation, muscle loss, and reduced strength, even without significant metabolic biomarker changes. Further research is warranted to elucidate the long-term clinical implications of these findings and the external validity in larger cohorts. Full article
(This article belongs to the Special Issue Body Composition and Nutritional Status in Cancer Patients)
Show Figures

Figure 1

16 pages, 5818 KiB  
Case Report
Novel Sonoguided Digital Palpation and Ultrasound-Guided Hydrodissection of the Long Thoracic Nerve for Managing Serratus Anterior Muscle Pain Syndrome: A Case Report with Technical Details
by Nunung Nugroho, King Hei Stanley Lam, Theodore Tandiono, Teinny Suryadi, Anwar Suhaimi, Wahida Ratnawati, Daniel Chiung-Jui Su, Yonghyun Yoon and Kenneth Dean Reeves
Diagnostics 2025, 15(15), 1891; https://doi.org/10.3390/diagnostics15151891 - 28 Jul 2025
Viewed by 1092
Abstract
Background and Clinical Significance: Serratus Anterior Muscle Pain Syndrome (SAMPS) is an underdiagnosed cause of anterior chest wall pain, often attributed to myofascial trigger points of the serratus anterior muscle (SAM) or dysfunction of the Long Thoracic Nerve (LTN), leading to significant disability [...] Read more.
Background and Clinical Significance: Serratus Anterior Muscle Pain Syndrome (SAMPS) is an underdiagnosed cause of anterior chest wall pain, often attributed to myofascial trigger points of the serratus anterior muscle (SAM) or dysfunction of the Long Thoracic Nerve (LTN), leading to significant disability and affecting ipsilateral upper limb movement and quality of life. Current diagnosis relies on exclusion and physical examination, with limited treatment options beyond conservative approaches. This case report presents a novel approach to chronic SAMPS, successfully diagnosed using Sonoguided Digital Palpation (SDP) and treated with ultrasound-guided hydrodissection of the LTN using 5% dextrose in water (D5W) without local anesthetic (LA), in a patient where conventional treatments had failed. Case Presentation: A 72-year-old male presented with a three-year history of persistent left chest pain radiating to the upper back, exacerbated by activity and mimicking cardiac pain. His medical history included two percutaneous coronary interventions. Physical examination revealed tenderness along the anterior axillary line and a positive hyperirritable spot at the mid axillary line at the 5th rib level. SDP was used to visualize the serratus anterior fascia (SAF) and LTN, and to reproduce the patient’s concordant pain by palpating the LTN. Ultrasound-guided hydrodissection of the LTN was then performed using 20–30cc of D5W without LA to separate the nerve from the surrounding tissues, employing a “fascial unzipping” technique. The patient reported immediate pain relief post-procedure, with the pain reducing from 9/10 to 1/10 on the Numeric Rating Scale (NRS), and sustained relief and functional improvement at the 12-month follow-up. Conclusions: Sonoguided Digital Palpation (SDP) of the LTN can serve as a valuable diagnostic adjunct for visualizing and diagnosing SAMPS. Ultrasound-guided hydrodissection of the LTN with D5W without LA may provide a promising and safe treatment option for patients with chronic SAMPS refractory to conservative management, resulting in rapid and sustained pain relief. Further research, including controlled trials, is warranted to evaluate the long-term efficacy and generalizability of these findings and to compare D5W to other injectates. Full article
Show Figures

Figure 1

20 pages, 1273 KiB  
Article
Safety and Anatomical Accuracy of Dry Needling of the Quadratus Femoris Muscle: A Cadaveric Study
by Marta Sánchez-Montoya, Jaime Almazán-Polo, Néstor Vallecillo Hernández, Charles Cotteret, Fabien Guerineau, Domingo de Guzman Monreal-Redondo and Ángel González-de-la-Flor
Healthcare 2025, 13(15), 1828; https://doi.org/10.3390/healthcare13151828 - 26 Jul 2025
Viewed by 280
Abstract
Introduction: Deep dry needling (DDN) is commonly applied in physiotherapy to treat musculoskeletal pain. The quadratus femoris (QF) muscle, located in the ischiofemoral space (IFS), represents a clinically relevant yet anatomically complex target. However, limited evidence exists on the safety, accuracy, and reliability [...] Read more.
Introduction: Deep dry needling (DDN) is commonly applied in physiotherapy to treat musculoskeletal pain. The quadratus femoris (QF) muscle, located in the ischiofemoral space (IFS), represents a clinically relevant yet anatomically complex target. However, limited evidence exists on the safety, accuracy, and reliability of non-ultrasound-guided DDN in this region. Aims: To assess the safety and accuracy of a standardized, non-ultrasound-guided DDN approach to the QF muscle, and to evaluate the intra- and inter-rater reliability of key procedural outcomes. Additionally, to determine the agreement between ultrasound imaging and anatomical dissection as validation methods for needle placement. Methods: An experimental cross-sectional study was conducted on five fresh cadavers (n = 24 approaches) by two physiotherapists with different DN experience. A standardized dry needling protocol was executed without ultrasound guidance, and anatomical and procedural variables were documented. Reliability (intra/inter-rater) was assessed for needle size, sciatic nerve (SN) puncture, IFS targeting, and overall success. In a subset, needle placement was validated through ultrasound and subsequent dissection. Results: The IFS was reached in 70.8% of procedures, and the SN was punctured in 16.7%. Inter-rater reliability for needle size was poor (κ = 0.04). Agreement between ultrasound and dissection was excellent for the ischiofemoral location and success (100%) and moderate for non SN puncture (90%; κ = 0.62). Conclusions: The standardized protocol demonstrated moderate accuracy and revealed a relevant clinical risk when targeting the quadratus femoris muscle. While inter-rater reliability was limited, agreement between ultrasound and dissection methods was high, supporting their complementary use for validating needle placement in anatomically complex procedures. Full article
Show Figures

Figure 1

13 pages, 2016 KiB  
Article
Pelvic Floor Adaptation to a Prenatal Exercise Program: Does It Affect Labor Outcomes or Levator Ani Muscle Injury? A Randomized Controlled Trial
by Aránzazu Martín-Arias, Irene Fernández-Buhigas, Daniel Martínez-Campo, Adriana Aquise Pino, Valeria Rolle, Miguel Sánchez-Polan, Cristina Silva-Jose, Maria M. Gil and Belén Santacruz
Diagnostics 2025, 15(15), 1853; https://doi.org/10.3390/diagnostics15151853 - 23 Jul 2025
Viewed by 469
Abstract
Background: Physical exercise during pregnancy is strongly recommended due to its well-established benefits for both mother and child. However, its impact on the pelvic floor remains insufficiently studied. This study aimed to evaluate pelvic floor adaptations to a structured prenatal exercise program using [...] Read more.
Background: Physical exercise during pregnancy is strongly recommended due to its well-established benefits for both mother and child. However, its impact on the pelvic floor remains insufficiently studied. This study aimed to evaluate pelvic floor adaptations to a structured prenatal exercise program using transperineal ultrasound, and to assess associations with the duration of the second stage of labor and mode of delivery. Methods: This is a planned secondary analysis of a randomized controlled clinical trial (RCT) (NCT04563065) including women with singleton pregnancies at 12–14 weeks of gestation. Participants were randomized to either an exercise group, which followed a supervised physical exercise program three times per week, or a control group, which received standard antenatal care. Transperineal ultrasound was used at the second trimester of pregnancy and six months postpartum to measure urogenital hiatus dimensions at rest, during maximal pelvic floor contraction, and during the Valsalva maneuver, to calculate hiatal contractility and distensibility and to evaluate levator ani muscle insertion. Regression analyses were performed to assess the relationship between urogenital hiatus measurements and both duration of the second stage of labor and mode of delivery. Results: A total of 78 participants were included in the final analysis: 41 in the control group and 37 in the exercise group. The anteroposterior diameter of the urogenital hiatus at rest was significantly smaller in the exercise group compared to controls (4.60 mm [SD 0.62] vs. 4.91 mm [SD 0.76]; p = 0.049). No other statistically significant differences were observed in static measurements. However, contractility was significantly reduced in the exercise group for both the latero-lateral diameter (8.54% vs. 4.04%; p = 0.012) and hiatus area (20.15% vs. 12.55%; p = 0.020). Distensibility was similar between groups. There were no significant differences in the duration of the second stage of labor or mode of delivery. Six months after delivery, there was an absolute risk reduction of 32.5% of levator ani muscle avulsion in the exercise group compared to the control group (53.3% and 20.8%, respectively; p = 0.009). Conclusions: A supervised exercise program during pregnancy appears to modify pelvic floor morphology and function, reducing the incidence of levator ani muscle avulsion without affecting the type or duration of delivery. These findings support the safety and potential protective role of prenatal exercise in maintaining pelvic floor integrity. Full article
Show Figures

Figure 1

11 pages, 2700 KiB  
Article
Description of Ultrasound-Guided Lumbar Erector Spinae Plane (ESP) Block and Comparison of the Spread of Two Volumes of Dye in Cat Cadavers
by Adriana Vasconcelos Nobre, Heytor Jales Gurgel, Elaine Cristina Batista Torres, Geovana de Lima Aleixo, Daiara Joana Lima de Farias, Paulo de Souza Júnior and Roberto Thiesen
Animals 2025, 15(15), 2157; https://doi.org/10.3390/ani15152157 - 22 Jul 2025
Viewed by 212
Abstract
The erector spinae plane (ESP) block is a widely used technique for perioperative analgesia. It involves the infiltration of anesthetics into the interfacial plane between the erector spinae muscle and the transverse processes of the vertebrae. In veterinary medicine, this technique has been [...] Read more.
The erector spinae plane (ESP) block is a widely used technique for perioperative analgesia. It involves the infiltration of anesthetics into the interfacial plane between the erector spinae muscle and the transverse processes of the vertebrae. In veterinary medicine, this technique has been adapted for different species, but there are no cadaveric studies in cats. This study describes the ultrasound-guided lumbar ESP-block technique and evaluates the spread of two volumes of dye in feline cadavers. Injections were performed at the second lumbar vertebra (L2) level using 0.6 mL/kg (high volume [HV]) and 0.4 mL/kg (low volume [LV]) of methylene blue bilaterally. After anatomical dissection, the distribution of the dye, the staining of the spinal nerve branches, and the presence of dye in the epidural space were recorded. The results demonstrated that the HV treatment provided wider longitudinal distribution, staining the dorsal branch of the spinal nerves in an average of five segments per injection, without extravasation into the epidural space. It is concluded that the HV treatment promotes efficient multisegmental spread in feline cadavers. Full article
(This article belongs to the Section Veterinary Clinical Studies)
Show Figures

Figure 1

14 pages, 4344 KiB  
Article
Ultrasound-Based Morphological and Functional Assessment in Male CrossFit Athletes with Unilateral Subacromial Shoulder Pain: An Observational Study
by Fabien Guerineau, Ann Cools, Jaime Almazán-Polo, María Dolores Sosa-Reina, Vanesa Abuín-Porras, Cristian Baroa-Fernández, Pablo García-Ginés, Ana Román-Franganillo and Ángel González-de-la-Flor
Medicina 2025, 61(7), 1304; https://doi.org/10.3390/medicina61071304 - 19 Jul 2025
Viewed by 276
Abstract
Background and Objectives: CrossFit is a discipline involving a wide range of overhead movements performed at high intensity and under accumulated fatigue that predispose to a high risk of shoulder complex injuries. This study aimed to compare ultrasonographic findings between symptomatic and [...] Read more.
Background and Objectives: CrossFit is a discipline involving a wide range of overhead movements performed at high intensity and under accumulated fatigue that predispose to a high risk of shoulder complex injuries. This study aimed to compare ultrasonographic findings between symptomatic and asymptomatic shoulders in CrossFit athletes. Materials and Methods: A cross-sectional study was conducted to compare ultrasound parameters between the painful and non-painful shoulders in CrossFit athletes with unilateral subacromial shoulder pain. Assessed variables included subacromial subdeltoid bursa thickness, supraspinatus tendon thickness, the acromiohumeral distance, the coracoacromial ligament distance, the bicipital groove angle, cross-sectional area of the biceps brachii longus head tendon, as well as the serratus anterior and lower trapezius muscle thickness. Results: Twenty male CrossFit athletes (forty shoulders) with an average age of 25.70 ± 4.03 years participated in the study. A statistically significant increase was observed (p < 0.05) in the subacromial subdeltoid bursa thickness in the painful shoulder compared to the asymptomatic side. All other ultrasound parameters did not show statistically significant differences. Conclusions: Only subacromial subdeltoid bursa thickness differed significantly between sides. This isolated finding may not fully explain shoulder pain, which cannot be solely attributed to morphological changes. Further research is needed to determine the relationship between shoulder pain and ultrasound features in CrossFit athletes, as well as the role of ultrasound in predicting structural changes in pain conditions. Full article
(This article belongs to the Special Issue Recent Trends in Physical Therapy for Musculoskeletal Disorders)
Show Figures

Figure 1

31 pages, 3523 KiB  
Article
Sustainable Tunable Anisotropic Ultrasound Medical Phantoms for Skin, Skeletal Muscle, and Other Fibrous Biological Tissues Using Natural Fibers and a Bio-Elastomeric Matrix
by Nuno A. T. C. Fernandes, Diana I. Alves, Diana P. Ferreira, Maria Monteiro, Ana Arieira, Filipe Silva, Betina Hinckel, Ana Leal and Óscar Carvalho
J. Compos. Sci. 2025, 9(7), 370; https://doi.org/10.3390/jcs9070370 - 16 Jul 2025
Viewed by 511
Abstract
Medical phantoms are essential to imaging calibration, clinician training, and the validation of therapeutic procedures. However, most ultrasound phantoms prioritize acoustic realism while neglecting the viscoelastic and anisotropic properties of fibrous soft tissues. This gap limits their effectiveness in modeling realistic biomechanical behavior, [...] Read more.
Medical phantoms are essential to imaging calibration, clinician training, and the validation of therapeutic procedures. However, most ultrasound phantoms prioritize acoustic realism while neglecting the viscoelastic and anisotropic properties of fibrous soft tissues. This gap limits their effectiveness in modeling realistic biomechanical behavior, especially in wave-based diagnostics and therapeutic ultrasound. Current materials like gelatine and agarose fall short in reproducing the complex interplay between the solid and fluid components found in biological tissues. To address this, we developed a soft, anisotropic composite whose dynamic mechanical properties resemble fibrous biological tissues such as skin and skeletal muscle. This material enables wave propagation and vibration studies in controllably anisotropic media, which are rare and highly valuable. We demonstrate the tunability of damping and stiffness aligned with fiber orientation, providing a versatile platform for modeling soft-tissue dynamics and validating biomechanical simulations. The phantoms achieved Young’s moduli of 7.16–11.04 MPa for skin and 0.494–1.743 MPa for muscles, shear wave speeds of 1.51–5.93 m/s, longitudinal wave speeds of 1086–1127 m/s, and sound absorption coefficients of 0.13–0.76 dB/cm/MHz, with storage, loss, and complex moduli reaching 1.035–6.652 kPa, 0.1831–0.8546 kPa, and 2.138–10.82 kPa. These values reveal anisotropic response patterns analogous to native tissues. This novel natural fibrous composite system affords sustainable, low-cost ultrasound phantoms that support both mechanical fidelity and acoustic realism. Our approach offers a route to next-gen tissue-mimicking phantoms for elastography, wave propagation studies, and dynamic calibration across diverse clinical and research applications. Full article
Show Figures

Graphical abstract

17 pages, 373 KiB  
Review
Innovations in Stress Urinary Incontinence: A Narrative Review
by Tamas Szabo, Melinda-Ildiko Mitranovici, Liviu Moraru, Dan Costachescu, Laura Georgiana Caravia, Elena Bernad, Viviana Ivan, Adrian Apostol, Mihai Munteanu and Lucian Puscasiu
Medicina 2025, 61(7), 1272; https://doi.org/10.3390/medicina61071272 - 14 Jul 2025
Viewed by 491
Abstract
Urinary incontinence is characterized by the involuntary leakage of urine. The primary cause of stress urinary incontinence in women is the weakening of the pelvic floor muscles. Stress urinary incontinence (SUI) is a significant global health problem that impacts mainly middle-aged women, with [...] Read more.
Urinary incontinence is characterized by the involuntary leakage of urine. The primary cause of stress urinary incontinence in women is the weakening of the pelvic floor muscles. Stress urinary incontinence (SUI) is a significant global health problem that impacts mainly middle-aged women, with a severe impact on their quality of life. Traditional diagnostic methods and treatments often fail, although technological innovations have improved diagnostic accuracy, such as specific questionnaires or transperineal ultrasound. While medical therapies and surgical procedures are continuously being developed, controversies about the correct choices regarding diagnostic and treatment methods continue to exist. The aim of our review was to identify the innovative diagnostic tools and effective treatment procedures for SUI. A narrative review was conducted due to the heterogeneity of the studies. New methods for diagnosis and treatment have gained ground, and we have covered them in our review; however, the field continues to expand. A personalized approach to diagnosis is also a requirement because of the limitations of conventional urodynamic studies, and we emphasize the importance of such personalization in enhancing clinical decision making. Future medical strategies that combine both preventive and therapeutic care are desirable. Newer technologies were brought to light in this review, including stem cell therapy and laser therapy. Full article
(This article belongs to the Special Issue New Insights into Gynecological Disease)
13 pages, 2934 KiB  
Article
Mechanotransductive Activation of PPAR-γ by Low-Intensity Pulsed Ultrasound Induces Contractile Phenotype in Corpus Spongiosum Smooth Muscle Cells
by Huan Yu, Jianying Li, Zihan Xu, Zhiwei Peng, Min Wu, Yiqing Lv, Fang Chen, Mingming Yu and Yichen Huang
Biomedicines 2025, 13(7), 1701; https://doi.org/10.3390/biomedicines13071701 - 11 Jul 2025
Viewed by 347
Abstract
Background: Previously, we found that the pathological changes in the corpus spongiosum (CS) in hypospadias were mainly localized within smooth muscle tissue, presenting as a transformation from the contraction phenotype to synthesis. The role of low-intensity pulsed ultrasound (LIPUS) in regulating smooth muscle [...] Read more.
Background: Previously, we found that the pathological changes in the corpus spongiosum (CS) in hypospadias were mainly localized within smooth muscle tissue, presenting as a transformation from the contraction phenotype to synthesis. The role of low-intensity pulsed ultrasound (LIPUS) in regulating smooth muscle cells (SMCs) and angiogenesis has been confirmed. Objectives: To demonstrate the feasibility of regulating the phenotypic transformation of corpus spongiosum smooth muscle cells (CSSMCs) in hypospadias using LIPUS and to explore the potential mechanisms. Materials and Methods: The CSSMCs were extracted from CS in patients with proximal hypospadias. In vitro experiments were conducted to explore the appropriate LIPUS irradiation intensity and duration which could promote the phenotypic transformation of CSSMCs. A total of 71 patients with severe hypospadias were randomly divided into a control group and a LIPUS group to verify the in vivo transition effect of LIPUS. Consequently, the potential mechanisms by which LIPUS regulates the phenotypic transformation of CSSMCs were explored in vitro. Results: In vitro experiments showed that LIPUS with an intensity of 100 mW/cm2 and a duration of 10 min could significantly increase the expression of contraction markers in CSSMCs and decrease the expression of synthesis markers. Moreover, LIPUS stimulation could alter the phenotype of CSSMCs in patients with proximal hypospadias. RNA sequencing results revealed that peroxisome proliferator-activated receptor gamma (PPAR-γ) significantly increased after LIPUS stimulation. Overexpression of PPAR-γ significantly increased the expression of contraction markers in CSSMCs, and the knockdown of PPAR-γ blocked this effect. Conclusions: LIPUS can regulate the transition of CSSMCs from a synthetic to a contractile phenotype in hypospadias. The PPAR-γ-mediated signaling pathway is a possible mechanism involved in this process. Full article
(This article belongs to the Section Molecular and Translational Medicine)
Show Figures

Figure 1

Back to TopTop