Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (1,671)

Search Parameters:
Keywords = higher output power

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
27 pages, 4509 KiB  
Article
Numerical Simulation and Analysis of Performance of Switchable Film-Insulated Photovoltaic–Thermal–Passive Cooling Module for Different Design Parameters
by Cong Jiao, Zeyu Li, Tiancheng Ju, Zihan Xu, Zhiqun Xu and Bin Sun
Processes 2025, 13(8), 2471; https://doi.org/10.3390/pr13082471 - 5 Aug 2025
Abstract
Photovoltaic–thermal (PVT) technology has attracted considerable attention for its ability to significantly improve solar energy conversion efficiency by simultaneously providing electricity and heat during the day. PVT technology serves a purpose in condensers and subcoolers for passive cooling in refrigeration systems at night. [...] Read more.
Photovoltaic–thermal (PVT) technology has attracted considerable attention for its ability to significantly improve solar energy conversion efficiency by simultaneously providing electricity and heat during the day. PVT technology serves a purpose in condensers and subcoolers for passive cooling in refrigeration systems at night. In our previous work, we proposed a switchable film-insulated photovoltaic–thermal–passive cooling (PVT-PC) module to address the structural incompatibility between diurnal and nocturnal modes. However, the performance of the proposed module strongly depends on two key design parameters: the structural height and the vacuum level of the air cushion. In this study, a numerical model of the proposed module is developed to examine the impact of design and meteorological parameters on its all-day performance. The results show that diurnal performance remains stable across different structural heights, while nocturnal passive cooling power shows strong dependence on vacuum level and structural height, achieving up to 103.73 W/m2 at 10 mm height and 1500 Pa vacuum, which is comparable to unglazed PVT modules. Convective heat transfer enhancement, induced by changes in air cushion shape, is identified as the primary contributor to improved nocturnal cooling performance. Wind speed has minimal impact on electrical output but significantly enhances thermal efficiency and nocturnal convective cooling power, with a passive cooling power increase of up to 31.61%. In contrast, higher sky temperatures degrade nocturnal cooling performance due to diminished radiative exchange, despite improving diurnal thermal efficiency. These findings provide fundamental insights for optimizing the structural design and operational strategies of PVT-PC systems under varying environmental conditions. Full article
(This article belongs to the Special Issue Numerical Simulation of Flow and Heat Transfer Processes)
Show Figures

Figure 1

27 pages, 30231 KiB  
Article
Modelling and Simulation of a 3MW, Seventeen-Phase Permanent Magnet AC Motor with AI-Based Drive Control for Submarines Under Deep-Sea Conditions
by Arun Singh and Anita Khosla
Energies 2025, 18(15), 4137; https://doi.org/10.3390/en18154137 - 4 Aug 2025
Abstract
The growing need for high-efficiency and reliable propulsion systems in naval applications, particularly within the evolving landscape of submarine warfare, has led to an increased interest in multiphase Permanent Magnet AC motors. This study presents a modelling and simulation approach for a 3MW, [...] Read more.
The growing need for high-efficiency and reliable propulsion systems in naval applications, particularly within the evolving landscape of submarine warfare, has led to an increased interest in multiphase Permanent Magnet AC motors. This study presents a modelling and simulation approach for a 3MW, seventeen-phase Permanent Magnet AC motor designed for submarine propulsion, integrating an AI-based drive control system. Despite the advantages of multiphase motors, such as higher power density and enhanced fault tolerance, significant challenges remain in achieving precise torque and variable speed, especially for externally mounted motors operating under deep-sea conditions. Existing control strategies often struggle with the inherent nonlinearities, unmodelled dynamics, and extreme environmental variations (e.g., pressure, temperature affecting oil viscosity and motor parameters) characteristic of such demanding deep-sea applications, leading to suboptimal performance and compromised reliability. Addressing this gap, this research investigates advanced control methodologies to enhance the performance of such motors. A MATLAB/Simulink framework was developed to model the motor, whose drive system leverages an AI-optimised dual fuzzy-PID controller refined using the Harmony Search Algorithm. Additionally, a combination of Indirect Field-Oriented Control (IFOC) and Space Vector PWM strategies are implemented to optimise inverter switching sequences for precise output modulation. Simulation results demonstrate significant improvements in torque response and control accuracy, validating the efficacy of the proposed system. The results highlight the role of AI-based propulsion systems in revolutionising submarine manoeuvrability and energy efficiency. In particular, during a test case involving a speed transition from 75 RPM to 900 RPM, the proposed AI-based controller achieves a near-zero overshoot compared to an initial control scheme that exhibits 75.89% overshoot. Full article
Show Figures

Figure 1

28 pages, 13030 KiB  
Article
Meta-Heuristic Optimization for Hybrid Renewable Energy System in Durgapur: Performance Comparison of GWO, TLBO, and MOPSO
by Sudip Chowdhury, Aashish Kumar Bohre and Akshay Kumar Saha
Sustainability 2025, 17(15), 6954; https://doi.org/10.3390/su17156954 - 31 Jul 2025
Viewed by 185
Abstract
This paper aims to find an efficient optimization algorithm to bring down the cost function without compromising the stability of the system and respect the operational constraints of the Hybrid Renewable Energy System. To accomplish this, MATLAB simulations were carried out using three [...] Read more.
This paper aims to find an efficient optimization algorithm to bring down the cost function without compromising the stability of the system and respect the operational constraints of the Hybrid Renewable Energy System. To accomplish this, MATLAB simulations were carried out using three optimization techniques: Grey Wolf Optimization (GWO), Teaching–Learning-Based Optimization (TLBO), and Multi-Objective Particle Swarm Optimization (MOPSO). The study compared their outcomes to identify which method yielded the most effective performance. The research included a statistical analysis to evaluate how consistently and stably each optimization method performed. The analysis revealed optimal values for the output power of photovoltaic systems (PVs), wind turbines (WTs), diesel generator capacity (DGs), and battery storage (BS). A one-year period was used to confirm the optimized configuration through the analysis of capital investment and fuel consumption. Among the three methods, GWO achieved the best fitness value of 0.24593 with an LPSP of 0.12528, indicating high system reliability. MOPSO exhibited the fastest convergence behaviour. TLBO yielded the lowest Net Present Cost (NPC) of 213,440 and a Cost of Energy (COE) of 1.91446/kW, though with a comparatively higher fitness value of 0.26628. The analysis suggests that GWO is suitable for applications requiring high reliability, TLBO is preferable for cost-sensitive solutions, and MOPSO is advantageous for obtaining quick, approximate results. Full article
(This article belongs to the Special Issue Energy Technology, Power Systems and Sustainability)
Show Figures

Figure 1

9 pages, 651 KiB  
Article
Intracycle Velocity Variation During a Single-Sculling 2000 m Rowing Competition
by Joana Leão, Ricardo Cardoso, Jose Arturo Abraldes, Susana Soares, Beatriz B. Gomes and Ricardo J. Fernandes
Sensors 2025, 25(15), 4696; https://doi.org/10.3390/s25154696 - 30 Jul 2025
Viewed by 226
Abstract
Rowing is a cyclic sport that consists of repetitive biomechanical actions, with performance being influenced by the balance between propulsive and resistive forces. The current study aimed to assess the relationships between intracycle velocity variation (IVV) and key biomechanical and performance variables in [...] Read more.
Rowing is a cyclic sport that consists of repetitive biomechanical actions, with performance being influenced by the balance between propulsive and resistive forces. The current study aimed to assess the relationships between intracycle velocity variation (IVV) and key biomechanical and performance variables in male and female single scullers. Twenty-three experienced rowers (10 females) completed a 2000 m rowing competition, during which boat position and velocity were measured using a 15 Hz GPS, while cycle rate was derived from the integrated triaxial accelerometer sampling at 100 Hz. From these data, it was possible to calculate distance per cycle, IVV, the coefficient of velocity variation (CVV), and technical index values. Males presented higher mean, maximum and minimum velocity, distance per cycle, CVV, and technical index values than females (15.40 ± 0.81 vs. 13.36 ± 0.88 km/h, d = 0.84; 21.39 ± 1.68 vs. 18.77 ± 1.52 km/h, d = 1.61; 11.15 ± 1.81 vs. 9.03 ± 0.85 km/h, d = 1.45; 7.68 ± 0.32 vs. 6.89 ± 0.97 m, d = 0.69; 14.13 ± 2.02 vs. 11.64 ± 1.93%, d = 2.06; and 34.25 ± 4.82 vs. 26.30 ± 4.23 (m2/s·cycle), d = 4.56, respectively). An association between mean velocity and intracycle IVV, CVV, and cycle rate (r = 0.68, 0.74 and 0.65, respectively) was observed in males but not in female single scullers (which may be attributed to anthropometric specificities). In female single scullers, mean velocity was related with distance per cycle and was associated with technical index in both males and females (r = 0.76 and 0.66, respectively). Despite these differences, male and female single scullers adopted similar pacing strategies and CVV remained constant throughout the 2000 m race (indicating that this variable might not be affected by fatigue). Differences were also observed in the velocity–time profile, with men reaching peak velocity first and having a faster propulsive phase. Data provided new information on how IVV and CVV relate to commonly used biomechanical variables in rowing. Technical index (r = 0.87): distance per cycle was associated with technical index in both males and females (r = 0.76 and 0.66, respectively). Future studies should include other boat classes and other performance variables such as the power output and arc length. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

17 pages, 2003 KiB  
Article
Effect of Caffeinated Chewing Gum on Maximal Strength, Muscular Power, and Muscle Recruitment During Bench Press and Back Squat Exercises
by Li Ding, Jue Liu, Yixuan Ma, Tze-Huan Lei, Mathew Barnes, Li Guo, Bin Chen, Yinhang Cao and Olivier Girard
Nutrients 2025, 17(15), 2455; https://doi.org/10.3390/nu17152455 - 28 Jul 2025
Viewed by 477
Abstract
Background/Objectives: This study aims to investigate the effects of caffeinated chewing gum on maximal strength, muscular power, and neural drive to the prime movers during bench press and back squat in resistance-trained men. Methods: Sixteen resistance-trained males participated in a double-blind, [...] Read more.
Background/Objectives: This study aims to investigate the effects of caffeinated chewing gum on maximal strength, muscular power, and neural drive to the prime movers during bench press and back squat in resistance-trained men. Methods: Sixteen resistance-trained males participated in a double-blind, randomized trial, chewing either caffeinated gum (4 mg/kg) or placebo gum on two separate occasions, seven days apart. After chewing for 5 min, participants performed a maximal strength test followed by muscular power assessments at 25%, 50%, 75%, and 90% of their one-repetition maximum (1RM), completing with 3, 2, 1, and 1 repetition (s), respectively, for bench press and back squat. Surface electromyography data were recorded for each repetition. Results: Caffeinated gum did not significantly improve one-repetition maximum (1RM) for bench press (p > 0.05), but increased mean frequency (MF) and median frequency (MDF) in anterior deltoid, pectoralis major, and biceps brachii (all p < 0.05) compared to placebo. For back squat, 1RM increased with caffeinated gum, along with higher MF and MDF in vastus medialis (all p < 0.05). Caffeinated gum also improved mean and peak velocities, and mean and peak power outputs at 25–75% 1RM during the bench press (all p < 0.05), along with elevated MDF in pectoralis major and biceps brachii (all p < 0.05). Similar improvements were seen in mean and peak velocities during the back squat at 25–90% 1RM (all p < 0.05), along with higher MF and MDF in vastus medialis and increased normalized root mean square activity in gluteus maximus (all p < 0.05). Conclusions: Caffeinated chewing gum (4 mg/kg) enhanced muscular power (25–75% 1RM) in the bench press and improved maximal strength and muscular power (25–90% 1RM) in the back squat by increasing muscle recruitment in resistance-trained men. Full article
(This article belongs to the Special Issue Energy Drink Effectiveness on Human Health and Exercise Performance)
Show Figures

Figure 1

18 pages, 1296 KiB  
Article
A Comprehensive Comparison and Evaluation of AI-Powered Healthcare Mobile Applications’ Usability
by Hessah W. Alduhailan, Majed A. Alshamari and Heider A. M. Wahsheh
Healthcare 2025, 13(15), 1829; https://doi.org/10.3390/healthcare13151829 - 26 Jul 2025
Viewed by 504
Abstract
Objectives: Artificial intelligence (AI) symptom-checker apps are proliferating, yet their everyday usability and transparency remain under-examined. This study provides a triangulated evaluation of three widely used AI-powered mHealth apps: ADA, Mediktor, and WebMD. Methods: Five usability experts applied a 13-item AI-specific [...] Read more.
Objectives: Artificial intelligence (AI) symptom-checker apps are proliferating, yet their everyday usability and transparency remain under-examined. This study provides a triangulated evaluation of three widely used AI-powered mHealth apps: ADA, Mediktor, and WebMD. Methods: Five usability experts applied a 13-item AI-specific heuristic checklist. In parallel, thirty lay users (18–65 years) completed five health-scenario tasks on each app, while task success, errors, completion time, and System Usability Scale (SUS) ratings were recorded. A repeated-measures ANOVA followed by paired-sample t-tests was conducted to compare SUS scores across the three applications. Results: The analysis revealed statistically significant differences in usability across the apps. ADA achieved a significantly higher mean SUS score than both Mediktor (p = 0.0004) and WebMD (p < 0.001), while Mediktor also outperformed WebMD (p = 0.0009). Common issues across all apps included vague AI outputs, limited feedback for input errors, and inconsistent navigation. Each application also failed key explainability heuristics, offering no confidence scores or interpretable rationales for AI-generated recommendations. Conclusions: Even highly rated AI mHealth apps display critical gaps in explainability and error handling. Embedding explainable AI (XAI) cues such as confidence indicators, input validation, and transparent justifications can enhance user trust, safety, and overall adoption in real-world healthcare contexts. Full article
Show Figures

Figure 1

13 pages, 983 KiB  
Article
Physiological Demands Across Exercise Intensity Domains in Rowing: Implications of Weight Category and Sex Differences
by Manoel Rios, Ricardo Cardoso, Ana Sofia Monteiro, João Paulo Vilas-Boas and Ricardo J. Fernandes
Sports 2025, 13(8), 245; https://doi.org/10.3390/sports13080245 - 25 Jul 2025
Viewed by 217
Abstract
We examined the physiological demands of trained rowers across four exercise intensity domains (considering the effects of weight category and sex). Twenty-four trained rowers (12 lightweight and 12 heavyweight) performed 7 × 3 min incremental bouts on a Concept2 rowing ergometer (30 W [...] Read more.
We examined the physiological demands of trained rowers across four exercise intensity domains (considering the effects of weight category and sex). Twenty-four trained rowers (12 lightweight and 12 heavyweight) performed 7 × 3 min incremental bouts on a Concept2 rowing ergometer (30 W power increases and 60 s rest intervals). Performance, cardiorespiratory and metabolic responses were continuously assessed throughout the experimental protocol to characterize internal load across progressive exercise intensities. Statistical analyses included a repeated measures ANOVA test and independent t-tests (p ≤ 0.05). Heavyweight rowers exhibited greater absolute anaerobic energy production in the severe domain (41.25 ± 10.39 vs. 32.54 ± 5.92 kJ) (p = 0.02), higher peak metabolic power (up to 1.57 ± 0.30 vs. 1.48 ± 0.30 kW) (p = 0.001) and greater total energy expenditure (up to 277.52 ± 51.23 vs. 266.69 ± 51.59 kJ) (p = 0.001) than lightweight rowers, whereas the latter showed comparable relative cardiorespiratory responses to heavyweights. With respect to sex differences, males demonstrated higher oxygen uptake (from ~43–59 vs. ~34–48 mL·kg−1·min−1) (p = 0.001), ventilation (from ~78–146 vs. ~49–99 L·min−1) (p = 0.001), metabolic power (from ~1.1–1.7 vs. ~0.7–1.0 kW) (p = 0.001) and energy expenditure (from ~193–305 vs. ~119–209 kJ) (p = 0.001) across all intensity domains. However, blood lactate levels and anaerobic energy contributions were similar between sexes. These findings demonstrated that domain-based physiological profiling effectively differentiates internal responses among rowers by weight category and sex. Heavyweights showed greater absolute energy output, while lightweights demonstrated higher metabolic efficiency. Males had elevated cardiorespiratory and metabolic values, but relative bioenergetic responses were similar across groups. These findings support individualized training based on physiological profiles. Full article
Show Figures

Figure 1

22 pages, 6221 KiB  
Article
Development and Experimental Validation of a Tubular Permanent Magnet Linear Alternator for Free-Piston Engine Applications
by Parviz Famouri, Jayaram Subramanian, Fereshteh Mahmudzadeh-Ghomi, Mehar Bade, Terence Musho and Nigel Clark
Machines 2025, 13(8), 651; https://doi.org/10.3390/machines13080651 - 25 Jul 2025
Viewed by 287
Abstract
The ongoing rise in global electricity demand highlights the need for advanced, efficient, and environmentally responsible energy conversion technologies. This research presents a comprehensive design, modeling, and experimental validation of a tubular permanent magnet linear alternator (PMLA) integrated with a free piston engine [...] Read more.
The ongoing rise in global electricity demand highlights the need for advanced, efficient, and environmentally responsible energy conversion technologies. This research presents a comprehensive design, modeling, and experimental validation of a tubular permanent magnet linear alternator (PMLA) integrated with a free piston engine system. Linear alternators offer a direct conversion of linear motion to electricity, eliminating the complexity and losses associated with rotary generators and enabling higher efficiency and simplified system architecture. The study combines analytical modeling, finite element simulations, and a sensitivity-based design optimization to guide alternator and engine integration. Two prototype systems, designated as alpha and beta, were developed, modeled, and tested. The beta prototype achieved a maximum electrical output of 550 W at 57% efficiency using natural gas fuel, demonstrating reliable performance at elevated reciprocating frequencies. The design and optimization of specialized flexure springs were essential in achieving stable, high-frequency operation and improved power density. These results validate the effectiveness of the proposed design approach and highlight the scalability and adaptability of PMLA technology for sustainable power generation. Ultimately, this study demonstrates the potential of free piston linear generator systems as efficient, robust, and environmentally friendly alternatives to traditional rotary generators, with applications spanning hybrid electric vehicles, distributed energy systems, and combined heat and power. Full article
(This article belongs to the Section Electrical Machines and Drives)
Show Figures

Figure 1

20 pages, 21323 KiB  
Article
C Band 360° Triangular Phase Shift Detector for Precise Vertical Landing RF System
by Víctor Araña-Pulido, B. Pablo Dorta-Naranjo, Francisco Cabrera-Almeida and Eugenio Jiménez-Yguácel
Appl. Sci. 2025, 15(15), 8236; https://doi.org/10.3390/app15158236 - 24 Jul 2025
Viewed by 152
Abstract
This paper presents a novel design for precise vertical landing of drones based on the detection of three phase shifts in the range of ±180°. The design has three inputs to which the signal transmitted from an oscillator located at the landing point [...] Read more.
This paper presents a novel design for precise vertical landing of drones based on the detection of three phase shifts in the range of ±180°. The design has three inputs to which the signal transmitted from an oscillator located at the landing point arrives with different delays. The circuit increases the aerial tracking volume relative to that achieved by detectors with theoretical unambiguous detection ranges of ±90°. The phase shift measurement circuit uses an analog phase detector (mixer), detecting a maximum range of ±90°and a double multiplication of the input signals, in phase and phase-shifted, without the need to fulfill the quadrature condition. The calibration procedure, phase detector curve modeling, and calculation of the input signal phase shift are significantly simplified by the use of an automatic gain control on each branch, dwhich keeps input amplitudes to the analog phase detectors constant. A simple program to determine phase shifts and guidance instructions is proposed, which could be integrated into the same flight control platform, thus avoiding the need to add additional processing components. A prototype has been manufactured in C band to explain the details of the procedure design. The circuit uses commercial circuits and microstrip technology, avoiding the crossing of lines by means of switches, which allows the design topology to be extrapolated to much higher frequencies. Calibration and measurements at 5.3 GHz show a dynamic range greater than 50 dB and a non-ambiguous detection range of ±180°. These specifications would allow one to track the drone during the landing maneuver in an inverted cone formed by a surface with an 11 m radius at 10 m high and the landing point, when 4 cm between RF inputs is considered. The errors of the phase shifts used in the landing maneuver are less than ±3°, which translates into 1.7% losses over the detector theoretical range in the worst case. The circuit has a frequency bandwidth of 4.8 GHz to 5.6 GHz, considering a 3 dB variation in the input power when the AGC is limiting the output signal to 0 dBm at the circuit reference point of each branch. In addition, the evolution of phases in the landing maneuver is shown by means of a small simulation program in which the drone trajectory is inside and outside the tracking range of ±180°. Full article
(This article belongs to the Section Applied Physics General)
Show Figures

Figure 1

12 pages, 262 KiB  
Article
Sex Differences in Bench Press Strength and Power: A Velocity-Based Analysis Adjusted for Body Composition
by Olga López-Torres, Raúl Nieto-Acevedo, Amelia Guadalupe-Grau and Valentín Emilio Fernández Elías
J. Funct. Morphol. Kinesiol. 2025, 10(3), 284; https://doi.org/10.3390/jfmk10030284 - 24 Jul 2025
Viewed by 767
Abstract
Background: Resistance training (RT) promotes muscle hypertrophy and strength gains in both men and women. However, sex differences in neuromuscular performance, muscle fiber composition, and the hormonal environment influence strength and power adaptations. While men generally exhibit greater absolute and relative strength, it [...] Read more.
Background: Resistance training (RT) promotes muscle hypertrophy and strength gains in both men and women. However, sex differences in neuromuscular performance, muscle fiber composition, and the hormonal environment influence strength and power adaptations. While men generally exhibit greater absolute and relative strength, it remains unclear to what extent these differences persist across various load intensities. A better understanding of sex-specific strength and power profiles may help optimize training strategies. The aim of this study was to compare strength and power performance during the bench press exercise in physically active males and females, relative to body mass and fat-free mass (FFM). Methods: Twenty-nine physically active individuals (16 men: 21.3 ± 4.1 years, 13 women: 22.6 ± 4.9 years) performed a one-repetition maximum (1RM) test and an incremental velocity-based assessment at 45%, 55%, 65%, 75%, and 85% of the 1RM using a Smith machine. The barbell velocity was measured via a linear transducer, with the mean propulsive velocity (MPV) recorded for each load. Power-related variables (e.g., peak force [F0], maximal velocity [V0], and maximal power [Pmax]) were analyzed. To account for differences in body composition, data were adjusted for body mass and FFM. Results: Men exhibited significantly greater strength and power than women across most loads when adjusted for both body mass and fat-free mass (FFM) (p < 0.05). These differences were particularly pronounced when normalized to FFM (45–75%1RM; p = 0.001–0.031), with large effect sizes observed (ηp2 = 0.185–0.383). Notably, sex differences in mean propulsive velocity (MPV) disappeared at 85%1RM (p = 0.208; ηp2 = 0.06), suggesting that maximal neuromuscular recruitment may minimize sex-related disparities at higher intensities. Furthermore, men demonstrated significantly higher values in six of the seven power-related variables, with no significant differences in the %1RM required to achieve an optimal power output. Conclusions: These findings confirm that men exhibit greater strength and power than women, even after adjusting for body composition. However, at high relative loads (≥85%1RM), sex differences in movement velocity appear to diminish, likely due to similar recruitment patterns of high-threshold motor units. These results highlight the importance of sex-specific resistance training programs, particularly in relation to load prescription and the application of velocity-based training methods. Full article
20 pages, 3903 KiB  
Article
High-Performance Barium Titanate, Carbon Nanotube, and Styrene–Butadiene Rubber-Based Single Composite TENG for Energy Harvesting and Handwriting Recognition
by Md Najib Alam, Vineet Kumar, Youjung Kim, Dong-Joo Lee and Sang-Shin Park
Polymers 2025, 17(15), 2016; https://doi.org/10.3390/polym17152016 - 23 Jul 2025
Viewed by 282
Abstract
In this research, a single composite-type stretchable triboelectric nanogenerator (TENG) is proposed for efficient energy harvesting and handwriting recognition. The composite TENGs were fabricated by blending dielectric barium titanate (BT) and conductive carbon nanotubes (CNTs) in varying amounts into a styrene–butadiene rubber matrix. [...] Read more.
In this research, a single composite-type stretchable triboelectric nanogenerator (TENG) is proposed for efficient energy harvesting and handwriting recognition. The composite TENGs were fabricated by blending dielectric barium titanate (BT) and conductive carbon nanotubes (CNTs) in varying amounts into a styrene–butadiene rubber matrix. The energy harvesting efficiency depends on the type and amount of fillers, as well as their dispersion within the matrix. Stearic acid modification of BT enables near-nanoscale filler distribution, resulting in high energy conversion efficiencies. The composite achieved power efficiency, power density, charge efficiency, and charge density values of 1.127 nW/N, 8.258 mW/m3, 0.146 nC/N, and 1.072 mC/m3, respectively, under only 2% cyclic compressive strain at 0.85 Hz. The material performs better at low stress–strain ranges, exhibiting higher charge efficiency. The generated charge in the TENG composite is well correlated with the compressive stress, which provides a minimum activation pressure of 0.144 kPa, making it suitable for low-pressure sensing applications. A flat composite with dimensions of 0.02 × 6 × 5 cm3 can produce a power density of 26.04 W/m3, a charge density of 0.205 mC/m3, and an output voltage of 10 V from a single hand pat. The rubber composite also demonstrates high accuracy in handwriting recognition across different individuals, with clear differences in sensitivity curves. Repeated attempts by the same person show minimal deviation (<5%) in writing time. Additionally, the presence of reinforcing fillers enhances mechanical strength and durability, making the composite suitable for long-term cyclic energy harvesting and wearable sensor applications. Full article
(This article belongs to the Special Issue Polymeric Materials in Energy Conversion and Storage, 2nd Edition)
Show Figures

Graphical abstract

17 pages, 2690 KiB  
Article
Impact Analysis of Price Cap on Bidding Strategies of VPP Considering Imbalance Penalty Structures
by Youngkook Song, Yongtae Yoon and Younggyu Jin
Energies 2025, 18(15), 3927; https://doi.org/10.3390/en18153927 - 23 Jul 2025
Viewed by 225
Abstract
Virtual power plants (VPPs) enable the efficient participation of distributed renewable energy resources in electricity markets by aggregating them. However, the profitability of VPPs is challenged by market volatility and regulatory constraints, such as price caps and imbalance penalties. This study examines the [...] Read more.
Virtual power plants (VPPs) enable the efficient participation of distributed renewable energy resources in electricity markets by aggregating them. However, the profitability of VPPs is challenged by market volatility and regulatory constraints, such as price caps and imbalance penalties. This study examines the joint impact of varying price cap levels and imbalance penalty structures on the bidding strategies and revenues of VPPs. A stochastic optimization model was developed, where a three-stage scenario tree was utilized to capture the uncertainty in electricity prices and renewable generation output. Simulations were performed under various market conditions using real-world price and generation data from the Korean electricity market. The analysis reveals that higher price cap coefficients lead to greater revenue and more segmented bidding strategies, especially under asymmetric penalty structures. Segment-wise analysis of bid price–quantity pairs shows that over-bidding is preferred under upward-only penalty schemes, while under-bidding is preferred under downward-only ones. Notably, revenue improvement tapers off beyond a price cap coefficient of 0.8, which indicates that there exists an optimal threshold for regulatory design. The findings of this study suggest the need for coordination between price caps and imbalance penalties to maintain market efficiency while supporting renewable energy integration. The proposed framework also offers practical insights for market operators and policymakers seeking to balance profitability, adaptability, and stability in VPP-integrated electricity markets. Full article
(This article belongs to the Section C: Energy Economics and Policy)
Show Figures

Figure 1

9 pages, 414 KiB  
Article
Effects of a Short-Term Ballistic Training Program on Performance and Strength Deficit in Elite Youth Female Soccer Players
by Irineu Loturco, Bernardo Requena, Valter P. Mercer, Tulio B. M. A. Moura, Matheus G. A. Alexandre, Lucas D. Tavares and Lucas A. Pereira
Sports 2025, 13(7), 237; https://doi.org/10.3390/sports13070237 - 21 Jul 2025
Viewed by 417
Abstract
This study examined the effects of a short-term ballistic training program on neuromuscular performance and strength-deficit (SDef) in elite youth female soccer players. Twenty-two under-20 athletes completed a 4-week intervention during the pre-season phase, comprising 12 loaded and 8 unloaded ballistic training sessions [...] Read more.
This study examined the effects of a short-term ballistic training program on neuromuscular performance and strength-deficit (SDef) in elite youth female soccer players. Twenty-two under-20 athletes completed a 4-week intervention during the pre-season phase, comprising 12 loaded and 8 unloaded ballistic training sessions performed at maximal intended velocity. Pre- and post-intervention assessments included vertical jumps (squat jump [SJ], countermovement jump [CMJ]), sprinting speed (5, 10, and 20 m), one-repetition maximum (1RM) and peak force (PF) in the half-squat (HS), and peak power and velocity during jump squats (JS) at 30% of 1RM. SDef was calculated as the percentage difference in PF between 1RM in the HS and 30% 1RM. Significant improvements were observed in SJ, CMJ, sprint speed, 1RM-strength, and bar-derived mechanical outputs (ES = 1.18–1.66; p < 0.05), with no significant changes in SDef. These results indicate that elite youth female soccer players can improve strength-, power-, and speed-related capacities without compromising force production at higher movement velocities (thus maintaining their SDef). The improvements observed likely reflect the combined effect of a high-frequency, velocity-oriented training approach and a concurrent reduction in traditional technical–tactical (i.e., soccer-specific) training volume. This is the first study to demonstrate that ballistic exercises alone—when properly structured—can enhance neuromuscular performance in female soccer players without increasing SDef. These findings provide practical guidance for practitioners aiming to optimize physical development in team-sport athletes without relying on heavier training loads or extended resistance training sessions—and, especially, without compromising their ability to apply force at higher velocities. Full article
(This article belongs to the Special Issue Cutting-Edge Research on Physical Fitness Profile in Soccer Players)
Show Figures

Figure 1

16 pages, 4472 KiB  
Article
Effect of Low-Level Laser Therapy on Periodontal Host Cells and a Seven-Species Periodontitis Model Biofilm
by Selma Dervisbegovic, Susanne Bloch, Vera Maierhofer, Christian Behm, Xiaohui Rausch-Fan, Andreas Moritz, Christina Schäffer and Oleh Andrukhov
Int. J. Mol. Sci. 2025, 26(14), 6803; https://doi.org/10.3390/ijms26146803 - 16 Jul 2025
Viewed by 322
Abstract
Low-level laser therapy (LLLT) is gaining attention as an effective adjunct to non-surgical periodontal treatment. This study evaluates the potential of LLLT to reduce bacterial load in a clinically relevant in vitro subgingival biofilm model and its impact on the inflammatory response. A [...] Read more.
Low-level laser therapy (LLLT) is gaining attention as an effective adjunct to non-surgical periodontal treatment. This study evaluates the potential of LLLT to reduce bacterial load in a clinically relevant in vitro subgingival biofilm model and its impact on the inflammatory response. A subgingival biofilm model consisting of seven bacterial species was established. Primary human gingival fibroblasts (GFs) and periodontal ligament cells (PDLs) were cultured. Both biofilms and host cells were treated with the DenLase Diode Laser (980 nm) under various clinically relevant settings. The composition and structure of the seven-species biofilms were evaluated using quantitative PCR and fluorescence microscopy, respectively. The inflammatory response in host cells was analyzed by measuring the gene and protein expression levels of various inflammatory mediators. Laser treatment at power outputs ranging from 0.3 to 2 W had no significant effect on biofilm composition or architecture. LLLT, particularly at higher power settings, reduced the viability in both GFs and PDLs up to 70%. Gene expression levels of inflammatory mediators were only minimally influenced by laser treatment. However, LLLT significantly decreased the secretion of all examined cytokines. These findings suggest that LLLT with a 980 nm diode laser, under clinically relevant conditions, exerts anti-inflammatory rather than antimicrobial effects. Full article
Show Figures

Figure 1

15 pages, 4556 KiB  
Article
Vibration Suppression Algorithm for Electromechanical Equipment in Distributed Energy Supply Systems
by Huan Wang, Fangxu Han, Bo Zhang and Guilin Zhao
Energies 2025, 18(14), 3757; https://doi.org/10.3390/en18143757 - 16 Jul 2025
Viewed by 235
Abstract
In recent years, distributed energy power supply systems have been widely used in remote areas and extreme environments. However, the intermittent and uncertain output power may cause power grid fluctuations, leading to higher harmonics in electromechanical equipment, especially motors. For permanent magnet synchronous [...] Read more.
In recent years, distributed energy power supply systems have been widely used in remote areas and extreme environments. However, the intermittent and uncertain output power may cause power grid fluctuations, leading to higher harmonics in electromechanical equipment, especially motors. For permanent magnet synchronous motor (PMSM) systems, an electromagnetic (EM) vibration can cause problems such as energy loss and mechanical wear. Therefore, it is necessary to design control algorithms that can effectively suppress EM vibration. To this end, a vibration suppression algorithm for fractional-slot permanent magnet synchronous motors based on a d-axis current injection is proposed in this paper. Firstly, this paper analyzes the radial electromagnetic force of the fractional-slot PMSM to identify the main source of EM vibration in fractional-slot PMSMs. Based on this, the intrinsic relationship between the EM vibration of fractional-slot PMSMs and the d-axis and q-axis currents is explored, and a method for calculating the d-axis current to suppress the vibration is proposed. Experimental verification shows that the proposed algorithm can effectively suppress EM vibration. Full article
Show Figures

Figure 1

Back to TopTop