Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (501)

Search Parameters:
Keywords = film interference

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
23 pages, 3916 KiB  
Article
Leveraging Wearable Sensors for the Identification and Prediction of Defensive Pessimism Personality Traits
by You Zhou, Dongfen Li, Bowen Deng and Weiqian Liang
Micromachines 2025, 16(8), 906; https://doi.org/10.3390/mi16080906 (registering DOI) - 2 Aug 2025
Viewed by 248
Abstract
Defensive pessimism, an important emotion regulation and motivation strategy, has increasingly attracted scholarly attention in psychology. Recently, sensor-based methods have begun to supplement or replace traditional questionnaire surveys in personality research. However, current approaches for collecting vital signs data face several challenges, including [...] Read more.
Defensive pessimism, an important emotion regulation and motivation strategy, has increasingly attracted scholarly attention in psychology. Recently, sensor-based methods have begun to supplement or replace traditional questionnaire surveys in personality research. However, current approaches for collecting vital signs data face several challenges, including limited monitoring durations, significant data deviations, and susceptibility to external interference. This paper proposes a novel approach using a NiCr/NiSi alloy film temperature sensor, which has a K-type structure and flexible piezoelectric pressure sensor to identify and predict defensive pessimism personality traits. Experimental results indicate that the Seebeck coefficients for K-, T-, and E-type thermocouples are approximately 41 μV/°C, 39 μV/°C, and 57 μV/°C, respectively, which align closely with national standards and exhibit good consistency across multiple experimental groups. Moreover, radial artery frequency experiments demonstrate a strong linear relationship between pulse rate and the intensity of external stimuli, where stronger stimuli correspond to faster pulse rates. Simulation experiments further reveal a high correlation between radial artery pulse frequency and skin temperature, and a regression model based on the physiological sensor data shows a good fit (p < 0.05). These findings verify the feasibility of using temperature and flexible piezoelectric pressure sensors to identify and predict defensive pessimism personality characteristics. Full article
Show Figures

Figure 1

16 pages, 4629 KiB  
Article
Development of a Reflective Electrochromic Zinc-Ion Battery Device for Infrared Emissivity Control Using Self-Doped Polyaniline Films
by Yi Wang, Ze Wang, Tong Feng, Jiandong Chen, Enkai Lin and An Xie
Polymers 2025, 17(15), 2110; https://doi.org/10.3390/polym17152110 - 31 Jul 2025
Viewed by 229
Abstract
Electrochromic devices (ECDs) capable of modulating both visible color and infrared (IR) emissivity are promising for applications in smart thermal camouflage and multifunctional displays. However, conventional transmissive ECDs suffer from limited IR modulation due to the low IR transmittance of transparent electrodes. Here, [...] Read more.
Electrochromic devices (ECDs) capable of modulating both visible color and infrared (IR) emissivity are promising for applications in smart thermal camouflage and multifunctional displays. However, conventional transmissive ECDs suffer from limited IR modulation due to the low IR transmittance of transparent electrodes. Here, we report a reflection-type electrochromic zinc-ion battery (HWEC-ZIB) using a self-doped polyaniline nanorod film (SP(ANI-MA)) as the active layer. By positioning the active material at the device surface, this structure avoids interference from transparent electrodes and enables broadband and efficient IR emissivity tuning. To prevent electrolyte-induced IR absorption, a thermal lamination encapsulation method is employed. The optimized device achieves emissivity modulation ranges of 0.28 (3–5 μm) and 0.19 (8–14 μm), delivering excellent thermal camouflage performance. It also exhibits a visible color change from earthy yellow to deep green, suitable for various natural environments. In addition, the HWEC-ZIB shows a high areal capacity of 72.15 mAh cm−2 at 0.1 mA cm−2 and maintains 80% capacity after 5000 cycles, demonstrating outstanding electrochemical stability. This work offers a versatile device platform integrating IR stealth, visual camouflage, and energy storage, providing a promising solution for next-generation adaptive camouflage and defense-oriented electronics. Full article
(This article belongs to the Section Smart and Functional Polymers)
Show Figures

Figure 1

17 pages, 5896 KiB  
Article
Simulation Study of the Effect of Oil Injection Speed on the Air Curtain of High-Speed Bearings
by Yanfang Dong, Botao Ye, Zibo Yan, Hai Zhang, Wei Yu, Jianyong Sun and Wenbo Zhou
Lubricants 2025, 13(8), 334; https://doi.org/10.3390/lubricants13080334 - 30 Jul 2025
Viewed by 225
Abstract
In order to improve the lubrication efficiency in the bearing cavity, this study establishes a simulation model of the fluid domain of the bearing cavity based on the computational fluid dynamics (CFD) method and systematically studies the flow characteristics of the lubricant and [...] Read more.
In order to improve the lubrication efficiency in the bearing cavity, this study establishes a simulation model of the fluid domain of the bearing cavity based on the computational fluid dynamics (CFD) method and systematically studies the flow characteristics of the lubricant and its lubrication mechanism in the high-speed rotary bearing. In the process of high-speed bearing operation, the lubricant is subject to the combined effect of centrifugal force and contact pressure, gradually spreads to both sides of the steel ball, and forms a stable oil film after injection from the nozzle. However, due to the influence of high pressure distribution in the contact area, the actual formation of the oil film coverage is relatively limited. In order to further optimize the lubrication effect, this study focuses on investigating the influence law of different injection speeds and rotational speeds on the bearing air curtain effect. The results of the study show that when the air curtain effect is enhanced, there will be significant shear interference on the trajectory of the lubricant, which is manifested in the phenomenon of “buckling” at the end of the lubricant, thus reducing the lubrication efficiency. To address this problem, this study innovatively proposes the air curtain obstruction coefficient K as a quantitative evaluation index, and through numerical simulation, it is found that the lubricant can effectively overcome the air curtain obstruction and achieve a better lubrication coverage when the value of K is reduced to below 0.4. Based on this finding, the study further confirmed that the lubrication efficiency of bearings can be significantly improved under different operating conditions by rationally regulating the injection rate. Full article
Show Figures

Figure 1

15 pages, 2557 KiB  
Article
Multiline Laser Interferometry for Non-Contact Dynamic Morphing of Hierarchical Surfaces
by Biagio Audia, Caterina Maria Tone, Pasquale Pagliusi, Alfredo Mazzulla, George Papavieros, Vassilios Constantoudis and Gabriella Cipparrone
Biomimetics 2025, 10(8), 486; https://doi.org/10.3390/biomimetics10080486 - 23 Jul 2025
Viewed by 364
Abstract
Hierarchical surface structuring is a critical aspect of advanced materials design, impacting fields ranging from optics to biomimetics. Among several laser-based methods for complex structuring of photo-responsive surfaces, the broadband vectorial interferometry proposed here offers unique performances. Such a method leverages a polychromatic [...] Read more.
Hierarchical surface structuring is a critical aspect of advanced materials design, impacting fields ranging from optics to biomimetics. Among several laser-based methods for complex structuring of photo-responsive surfaces, the broadband vectorial interferometry proposed here offers unique performances. Such a method leverages a polychromatic laser source, an unconventional choice for holographic encoding, to achieve deterministic multiscale surface structuring through interference light patterning. Azopolymer films are used as photosensitive substrates. By exploring the interaction between optomechanical stress modulations at different spatial periodicities induced within the polymer bulk, we demonstrate the emergence of hierarchical Fourier surfaces composed of multiple deterministic levels. These structures range from sub-micrometer to tens of micrometers scale, exhibiting a high degree of control over their morphology. The experimental findings reveal that the optical encoding scheme significantly influences the resulting topographies. The polarization light patterns lead to more regular and symmetric hierarchical structures compared to those obtained with intensity patterns, underscoring the role of vectorial light properties in controlling surface morphologies. The proposed method is fully scalable, compatible with more complex recording schemes (including multi-beam interference), and it is applicable to a wide range of advanced technological fields. These include optics and photonics (diffractive elements, polarimetric devices), biomimetic surfaces, topographical design, information encoding, and anti-counterfeiting, offering a rapid, reliable, and versatile strategy for high-precision surface structuring at a submicrometric scale. Full article
Show Figures

Figure 1

20 pages, 1471 KiB  
Article
A New Approach for Interferent-Free Amperometric Biosensor Production Based on All-Electrochemically Assisted Procedures
by Rosanna Ciriello, Maria Assunta Acquavia, Giuliana Bianco, Angela Di Capua and Antonio Guerrieri
Biosensors 2025, 15(8), 470; https://doi.org/10.3390/bios15080470 - 22 Jul 2025
Viewed by 304
Abstract
A new approach in amperometric enzyme electrodes production based on all-electrochemically assisted procedures will be described. Enzyme (glucose oxidase) immobilization was performed by in situ co-crosslinking of enzyme molecules through electrophoretic protein deposition, assuring enzyme immobilization exclusively onto the transducer surface (Pt electrode). [...] Read more.
A new approach in amperometric enzyme electrodes production based on all-electrochemically assisted procedures will be described. Enzyme (glucose oxidase) immobilization was performed by in situ co-crosslinking of enzyme molecules through electrophoretic protein deposition, assuring enzyme immobilization exclusively onto the transducer surface (Pt electrode). Analogously, the poor selectivity of the transducer was dramatically improved by the electrosynthesis of non-conducting polymers with built-in permselectivity, permitting the formation of a thin permselective film onto the transducer surface, able to reject common interferents usually found in real samples. Since both approaches required a proper and distinct electrochemical perturbation (a pulsed current sequence for electrophoretic protein deposition and cyclic voltammetry for the electrosynthesis of non-conducting polymers), an appropriate coupling of the two all-electrochemical approaches was assured by a thorough study of the likely combinations of the electrosynthesis of permselective polymers with enzyme immobilization by electrophoretic protein deposition and by the use of several electrosynthesized polymers. For each investigated combination and for each polymer, the analytical performances and the rejection capabilities of the resulting biosensor were acquired so to gain information about their sensing abilities eventually in real sample analysis. This study shows that the proper coupling of the two all-electrochemical approaches and the appropriate choice of the electrosynthesized, permselective polymer permits the easy fabrication of novel glucose oxidase biosensors with good analytical performance and low bias in glucose measurement from typical interferent in serum. This novel approach, resembling classical electroplating procedures, is expected to allow all the advantages expected from such procedures like an easy preparation biosensor, a bi-dimensional control of enzyme immobilization and thickness, interferent- and fouling-free transduction of the electrodic sensor and, last but not the least, possibility of miniaturization of the biosensing device. Full article
(This article belongs to the Special Issue Novel Designs and Applications for Electrochemical Biosensors)
Show Figures

Figure 1

11 pages, 3598 KiB  
Article
NMR Spectroelectrochemistry in Studies of Procarbazine Oxidation by Laser-Induced Graphene Thin Films
by Zhe Wang, Xiaoping Zhang, Shihui Xu, Lin Yang, Lina Wang, Yijing Wang, Ahmad Mansoor and Wei Sun
C 2025, 11(3), 52; https://doi.org/10.3390/c11030052 - 21 Jul 2025
Viewed by 325
Abstract
In this paper, nanoscale graphene film electrodes were prepared using laser-induced technology, and an in situ electrochemical cell was constructed. The normalized peak areas at 2.82 ppm for the samples without the in situ electrochemical cell and with an in situ electrochemical cell [...] Read more.
In this paper, nanoscale graphene film electrodes were prepared using laser-induced technology, and an in situ electrochemical cell was constructed. The normalized peak areas at 2.82 ppm for the samples without the in situ electrochemical cell and with an in situ electrochemical cell are 4.02 and 4.41, respectively. Tests showed that this in situ electrochemical cell has minimal interference from the nuclear magnetic resonance (NMR) magnetic field, allowing for high-resolution in situ spectra. Using this in situ electrochemical cell and employing in situ electrochemistry combined with NMR techniques, we investigated the oxidation reaction of 0.01 M procarbazine (PCZ) in real-time. We elucidated the following oxidation mechanism for procarbazine: the oxidation of PCZ first generates azo-procarbazine, which then undergoes a double bond shift to hydrazo-procarbazine. hydrazo-procarbazine undergoes hydrolysis to yield benzaldehyde-procarbazine, and then finally oxidizes to produce N-isopropylterephthalic acid. This confirms that the combination of in situ electrochemistry and nuclear magnetic resonance technology provides chemists with an effective tool for in situ studying the reaction mechanisms of drug molecules. Full article
(This article belongs to the Section Carbon Materials and Carbon Allotropes)
Show Figures

Graphical abstract

19 pages, 3806 KiB  
Article
Electroactive Poly(amic acid) Films Grafted with Pendant Aniline Tetramer for Hydrogen Sulfide Gas Sensing Applications
by Kun-Hao Luo, Yun-Ting Chen, Hsuan-Yu Wu, Zong-Kai Ni and Jui-Ming Yeh
Polymers 2025, 17(14), 1915; https://doi.org/10.3390/polym17141915 - 11 Jul 2025
Viewed by 381
Abstract
Hydrogen sulfide (H2S) is a highly toxic and corrosive gas generated in numerous industrial and environmental processes; rapid, sensitive detection at low ppm levels is therefore crucial for ensuring occupational safety and protecting public health. This work explores the effect of [...] Read more.
Hydrogen sulfide (H2S) is a highly toxic and corrosive gas generated in numerous industrial and environmental processes; rapid, sensitive detection at low ppm levels is therefore crucial for ensuring occupational safety and protecting public health. This work explores the effect of grafting various loadings of pendant aniline tetramer pendants (PEDA) onto electroactive poly(amic acid) (EPAA) films and evaluates their performance as H2S gas sensors. Comprehensive characterization including ion trap mass spectrometry (Ion trap MS), Fourier-transform infrared spectroscopy (FTIR), cyclic voltammetry (CV), and four-probe conductivity measurements, confirmed successful PEDA incorporation and revealed enhanced electrical conductivity with increasing PEDA content. Gas sensing tests revealed that EPAA3 (3 wt% PEDA) achieved the best overall performance toward 10 ppm H2S, producing a 591% response with a rapid 108 s response time. Selectivity studies showed that the response of EPAA3 to H2S exceeded those for SO2, NO2, NH3, and CO by factors of five to twelve, underscoring its excellent discrimination against common interferents. Repeatability tests over five successive cycles gave a relative standard deviation of just 7.4% for EPAA3, and long-term stability measurements over 16 days in ambient air demonstrated that EPAA3 retained over 80%. These findings establish that PEDA-grafted PAA films combine the processability of poly(amic acid) with the sharp, reversible redox behavior of pendant aniline tetramers, delivering reproducible, selective, and stable H2S sensing. EPAA3, in particular, represents a balanced composition that maximizes sensitivity and durability, offering a promising platform for practical environmental monitoring and industrial safety applications. Full article
(This article belongs to the Special Issue Development of Applications of Polymer-Based Sensors and Actuators)
Show Figures

Figure 1

37 pages, 5136 KiB  
Review
Advancements in Optical Fiber Sensors for pH Measurement: Technologies and Applications
by Alaa N. D. Alhussein, Mohammed R. T. M. Qaid, Timur Agliullin, Bulat Valeev, Oleg Morozov, Airat Sakhabutdinov and Yuri A. Konstantinov
Sensors 2025, 25(14), 4275; https://doi.org/10.3390/s25144275 - 9 Jul 2025
Viewed by 531
Abstract
Measuring pH is a critical parameter in environmental monitoring, biomedical diagnostics, food safety, and industrial processes. Optical fiber sensors have proven highly effective for pH detection due to their exceptional sensitivity, rapid response, and resistance to electromagnetic interference, making them well suited for [...] Read more.
Measuring pH is a critical parameter in environmental monitoring, biomedical diagnostics, food safety, and industrial processes. Optical fiber sensors have proven highly effective for pH detection due to their exceptional sensitivity, rapid response, and resistance to electromagnetic interference, making them well suited for real-time monitoring. This review offers a comprehensive analysis of recent advances in optical fiber-based pH sensors, covering key techniques such as fluorescence-based, absorbance-based, evanescent wave, and interferometric methods. Innovations in Fiber Bragg Grating and Surface Plasmon Resonance technologies are also examined. The discussion extends to the impact of pH-sensitive coatings—ranging from nanomaterials and polymeric films to graphene-based compounds—on enhancing sensor performance. Recent advancements have also enabled automation in data analysis and improvements in remote sensing capabilities. The review further compares the economic viability of optical fiber sensors with traditional electrochemical methods, while acknowledging persistent issues such as temperature cross-sensitivity, long-term stability, and fabrication costs. Overall, recent developments have broadened the functionality and application scope of these sensors by improving efficiency, accuracy, and scalability. Future research directions are outlined, including advanced optical interrogation techniques, such as Addressed Fiber Bragg Structures (AFBSs), microwave photonic integration, and optimized material selection. These approaches aim to enhance performance, reduce costs, and enable the broader adoption of optical fiber pH sensors. Full article
(This article belongs to the Special Issue Feature Review Papers in Optical Sensors)
Show Figures

Figure 1

18 pages, 16017 KiB  
Article
Design and Fabrication of Multi-Frequency and Low-Quality-Factor Capacitive Micromachined Ultrasonic Transducers
by Amirhossein Moshrefi, Abid Ali, Mathieu Gratuze and Frederic Nabki
Micromachines 2025, 16(7), 797; https://doi.org/10.3390/mi16070797 - 8 Jul 2025
Viewed by 500
Abstract
Capacitive micromachined ultrasonic transducers (CMUTs) have been developed for air-coupled applications to address key challenges such as noise, prolonged ringing, and side-lobe interference. This study introduces an optimized CMUT design that leverages the squeeze-film damping effect to achieve a low-quality factor, enhancing resolution [...] Read more.
Capacitive micromachined ultrasonic transducers (CMUTs) have been developed for air-coupled applications to address key challenges such as noise, prolonged ringing, and side-lobe interference. This study introduces an optimized CMUT design that leverages the squeeze-film damping effect to achieve a low-quality factor, enhancing resolution and temporal precision for imaging as one of the suggested airborne application. The device was fabricated using the PolyMUMPs process, ensuring high structural accuracy and consistency. Finite element analysis (FEA) simulations validated the optimized parameters, demonstrating improved displacement, reduced side-lobe artifacts, and sharper main lobes for superior imaging performance. Experimental validation, including Laser Doppler Vibrometer (LDV) measurements of membrane displacement and mode shapes, along with ring oscillation tests to assess Q-factor and signal decay, confirmed the device’s reliability and consistency across four CMUT arrays. Additionally, this study explores the implementation of multi-frequency CMUT arrays, enhancing imaging versatility across different air-coupled applications. By integrating multiple frequency bands, the proposed CMUTs enable adaptable imaging focus, improving their suitability for diverse diagnostic scenarios. These advancements highlight the potential of the proposed design to deliver a superior performance for airborne applications, paving the way for its integration into advanced diagnostic systems. Full article
(This article belongs to the Special Issue MEMS Ultrasonic Transducers)
Show Figures

Figure 1

18 pages, 2702 KiB  
Article
Real-Time Depth Monitoring of Air-Film Cooling Holes in Turbine Blades via Coherent Imaging During Femtosecond Laser Machining
by Yi Yu, Ruijia Liu, Chenyu Xiao and Ping Xu
Photonics 2025, 12(7), 668; https://doi.org/10.3390/photonics12070668 - 2 Jul 2025
Viewed by 369
Abstract
Given the exceptional capabilities of femtosecond laser processing in achieving high-precision ablation for air-film cooling hole fabrication on turbine blades, it is imperative to develop an advanced monitoring methodology that enables real-time feedback control to automatically terminate the laser upon complete penetration detection, [...] Read more.
Given the exceptional capabilities of femtosecond laser processing in achieving high-precision ablation for air-film cooling hole fabrication on turbine blades, it is imperative to develop an advanced monitoring methodology that enables real-time feedback control to automatically terminate the laser upon complete penetration detection, thereby effectively preventing backside damage. To tackle this issue, a spectrum-domain coherent imaging technique has been developed. This innovative approach adapts the fundamental principle of fiber-based Michelson interferometry by integrating the air-film hole into a sample arm configuration. A broadband super-luminescent diode with a 830 nm central wavelength and a 26 nm spectral bandwidth serves as the coherence-optimized illumination source. An optimal normalized reflectivity of 0.2 is established to maintain stable interference fringe visibility throughout the drilling process. The system achieves a depth resolution of 11.7 μm through Fourier transform analysis of dynamic interference patterns. With customized optical path design specifically engineered for through-hole-drilling applications, the technique demonstrates exceptional sensitivity, maintaining detection capability even under ultralow reflectivity conditions (0.001%) at the hole bottom. Plasma generation during laser processing is investigated, with plasma density measurements providing optical thickness data for real-time compensation of depth measurement deviations. The demonstrated system represents an advancement in non-destructive in-process monitoring for high-precision laser machining applications. Full article
(This article belongs to the Special Issue Advances in Laser Measurement)
Show Figures

Figure 1

34 pages, 6513 KiB  
Article
Planar Electrically Large Structures of Carbon Nanotube Films with High Absorption and Shielding Performance in X-Band
by Apostolos Sotiropoulos, Athanasios Masouras, Hristos T. Anastassiu, Vassilis Kostopoulos and Stavros Koulouridis
Sensors 2025, 25(13), 3943; https://doi.org/10.3390/s25133943 - 25 Jun 2025
Viewed by 614
Abstract
We consider light, high-absorbance, low-reflectance, electrically large layered sheet structures composed of thin carbon nanotube films. Such structures can be utilized in electromagnetic absorption and shielding applications in the X-band. They are of increasing interest in sensor-enabling technologies, stealth systems, and EMI shielding [...] Read more.
We consider light, high-absorbance, low-reflectance, electrically large layered sheet structures composed of thin carbon nanotube films. Such structures can be utilized in electromagnetic absorption and shielding applications in the X-band. They are of increasing interest in sensor-enabling technologies, stealth systems, and EMI shielding of electronic components. Especially in aerospace, this is crucial, as sensors are integral to aerospace engineering, enhancing the safety, efficiency, and performance of aircraft and spacecraft. To that end, sheets with carbon nanotube films embedded in a glass fiber polymer matrix are fabricated. The films have a thickness of around 70 μm. As shown, they cause a significant attenuation of the electromagnetic field. For shielding applications, a single-film sheet structure with total thickness of 1.65 mm presents an attenuation of around 25 dB in the transmission coefficient, while the attenuation can reach 37 dB for a two-film sheet structure with thickness of 1.8 mm. Shielding effectiveness performance is found to be greater than 35 dB for the two-film sheet structure. For applications requiring both high shielding and absorption, a two-layered structure with a thickness of 4.65 mm has been designed. The absorption, represented by the Loss Factor, is calculated to achieve values greater than 90%. The simulation results show good agreement with the measured data. The findings demonstrate a promising structure for materials suitable for sensor housings and smart electromagnetic environments where the suppression of electromagnetic interference is critical. In conclusion, the addition of carbon nanotube films, even at micrometer thicknesses, within a glass fiber polymer matrix significantly enhances both electromagnetic shielding and absorption performance. Full article
(This article belongs to the Special Issue Nanotechnology Applications in Sensors Development)
Show Figures

Figure 1

11 pages, 6486 KiB  
Article
Surface Charging on Insulating Films with Different Thicknesses in UPS
by Lei Zhu and Xuefeng Xu
Appl. Sci. 2025, 15(12), 6846; https://doi.org/10.3390/app15126846 - 18 Jun 2025
Viewed by 297
Abstract
The conventional view holds that ultraviolet photoelectron spectroscopy (UPS) measurements are not applicable to insulating materials due to interference from charging effects. To avoid surface charging, researchers typically restrict valence band structure investigations to ultra-thin films. However, the UPS spectral performance of ultra-thin [...] Read more.
The conventional view holds that ultraviolet photoelectron spectroscopy (UPS) measurements are not applicable to insulating materials due to interference from charging effects. To avoid surface charging, researchers typically restrict valence band structure investigations to ultra-thin films. However, the UPS spectral performance of ultra-thin films tends to correlate with the substrate characteristics and film thickness, while charging effects, which still unavoidably occur, can also affect the realism of the results. This study systematically investigates the charging effects and valence band structural evolution in SiO2 insulating films with controlled thickness variations through XPS and UPS depth profiling. By analyzing spectral shifts, surface potential dynamics, and work function variations, three continuous regimes are identified. The results demonstrate that the surface potential undergoes abrupt intensification when exceeding critical thickness thresholds (about 8 nm), a phenomenon governed by substrate resistivity and charge compensation pathways. Conventional work function determination methods remain valid only when the actual effect of the applied bias exceeds the surface potential values. For thicker films, the limited efficacy of negative bias fails to compensate for the spectral shifts caused by surface charging, consequently rendering work function measurements unreliable. These findings provide critical guidance for optimizing UPS measurements and spectral interpretation in insulating films. Full article
Show Figures

Figure 1

15 pages, 3537 KiB  
Article
High-Efficiency Broadband Selective Photothermal Absorbers Based on Multilayer Chromium Films
by Chu Li, Er-Tao Hu, Yu-Xiang Zheng, Song-You Wang, Yue-Mei Yang, Young-Pak Lee, Jun-Peng Guo, Qing-Yuan Cai, Wei-Bo Duan and Liang-Yao Chen
Crystals 2025, 15(6), 562; https://doi.org/10.3390/cryst15060562 - 14 Jun 2025
Viewed by 361
Abstract
Photothermal conversion is a pivotal energy transformation mechanism in solar energy systems. Achieving high-efficiency and broadband photothermal conversion within the solar radiation spectrum holds strategic significance in driving the innovative development of renewable energy technologies. In this study, a transmission matrix method was [...] Read more.
Photothermal conversion is a pivotal energy transformation mechanism in solar energy systems. Achieving high-efficiency and broadband photothermal conversion within the solar radiation spectrum holds strategic significance in driving the innovative development of renewable energy technologies. In this study, a transmission matrix method was employed to design an interference-type solar selective absorber based on multilayer Cr-SiO2 planar films, successfully achieving an average absorption of 94% throughout the entire solar spectral range. Further analysis indicates that this newly designed absorber shows excellent absorption performance even at a relatively large incident angle (up to 60°). Additionally, the newly designed absorber demonstrates lower polarization sensitivity, enabling efficient operation under complicated incident conditions. With its simple fabrication process and ease of preparation, the proposed absorber holds substantial potential for applications in photothermal conversion fields such as solar thermal collectors. Full article
(This article belongs to the Special Issue Preparation and Characterization of Optoelectronic Functional Films)
Show Figures

Figure 1

12 pages, 2936 KiB  
Article
Binder-Free Metal–Organic Framework-Derived Zn(CN)2/V2O3/Carbon Cathode Fabricated via Electrophoretic Deposition for High-Performance Zn-Ion Batteries
by Hyemin Lee and Byoungnam Park
Inorganics 2025, 13(6), 194; https://doi.org/10.3390/inorganics13060194 - 11 Jun 2025
Viewed by 480
Abstract
In this study, a Zn(CN)2–V2O3–C composite cathode was synthesized via AC electrophoretic deposition (EPD) and evaluated for application in aqueous zinc-ion batteries (ZIBs). Here, we report for the first time a binder-free Zn(CN)2–V2O [...] Read more.
In this study, a Zn(CN)2–V2O3–C composite cathode was synthesized via AC electrophoretic deposition (EPD) and evaluated for application in aqueous zinc-ion batteries (ZIBs). Here, we report for the first time a binder-free Zn(CN)2–V2O3–C composite cathode, using AC-EPD to create an ultrathin architecture optimized for probing the electrode–electrolyte interface without interference from additives or bulk effects. The composite combines Zn(CN)2 for structural support, V2O3 as the redox-active material, and carbon for improved conductivity. X-ray diffraction confirmed the presence of Zn(CN)2 and V2O3 phases, while scanning electron microscopy revealed a uniform, ultrathin film morphology. Electrochemical analysis demonstrated a hybrid charge storage mechanism with a b-value of 0.64, indicating both capacitive and diffusion-controlled contributions. The electrode delivered a high specific capacity (~250 mAh/g at 500 mA/g) with stable cycling performance. These results highlight the potential of metal–organic framework-derived composites for high-performance ZIB cathodes. The composite is especially effective when prepared via AC-EPD, which yields ultrathin, uniform films with strong adhesion and low agglomeration. This enhances energy storage performance and provides a reliable platform for focusing on interfacial charge storage, excluding the effect of binders on electrochemical performance. Full article
Show Figures

Figure 1

13 pages, 2540 KiB  
Article
Simple Nanochannel-Modified Electrode for Sensitive Detection of Alkaline Phosphatase Through Electrochemiluminescence Signal Quenching by Enzymatic Reaction
by Tianjun Ma, Xuan Luo, Fengna Xi and Nuo Yang
Biosensors 2025, 15(6), 377; https://doi.org/10.3390/bios15060377 - 11 Jun 2025
Cited by 1 | Viewed by 595
Abstract
Development of sensitive and convenient alkaline phosphatase (ALP) detection methods is of great significance for food analysis, biomedical applications, and clinical tests. In this work, a sensitive detection method for ALP was established based on nanochannel-modified electrodes, where the electrochemical luminescence (ECL) signal [...] Read more.
Development of sensitive and convenient alkaline phosphatase (ALP) detection methods is of great significance for food analysis, biomedical applications, and clinical tests. In this work, a sensitive detection method for ALP was established based on nanochannel-modified electrodes, where the electrochemical luminescence (ECL) signal was quenched by the enzymatic reaction product. Vertically ordered mesoporous silica film (VMSF) was rapidly grown on low-cost ITO via the electrochemically assisted self-assembly (EASA) method. The resulting modified electrode (VMSF/ITO) exhibited a uniform and ordered nanochannel structure with nanochannel diameter of 2–3 nm and charge-selective permeability, enabling the enrichment of cationic ECL emitter tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+). Compared to the ITO electrode, VMSF/ITO increased the ECL signal by 60 times. In the presence of ALP, it catalyzes the hydrolysis of its substrate, disodium phenyl phosphate hydrate (DPP), generating phenol (Phe), which quenched the ECL signal of Ru(bpy)32+ and the co-reactant N,N-Dipropyl-1-propanamine (TPA). Based on this principle, ECL detection of ALP can be achieved. The linear detection range for ALP was 0.01 U/L to 30 U/L, with a limit of detection (LOD) of 0.008 U/L. The sensor exhibited high selectivity. Combined with the anti-contamination and anti-interference capabilities of VMSF, the constructed sensor enabled the detection of ALP levels in milk samples. Full article
(This article belongs to the Special Issue Biosensing and Diagnosis—2nd Edition)
Show Figures

Figure 1

Back to TopTop