Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (45)

Search Parameters:
Keywords = air change rate (ACH)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 31399 KB  
Article
Multi-Objective Optimization of Passive Solar Chimney Ventilation in Eastern Algeria: A Case Study Combining Surrogate Modeling and Metaheuristic Search
by Billal Belfegas, Aissa Laouissi, Vasanth Swaminathan, Yacine Karmi, Raouache Elhadj and Mourad Nouioua
Energies 2026, 19(12), 2776; https://doi.org/10.3390/en19122776 - 9 Jun 2026
Viewed by 283
Abstract
Solar chimneys represent an effective passive ventilation technology capable of improving indoor thermal comfort while reducing building energy consumption. In this study, the thermal and fluid dynamic performance of a solar chimney integrated into a residential building located in Bordj Bou Arréridj (Eastern [...] Read more.
Solar chimneys represent an effective passive ventilation technology capable of improving indoor thermal comfort while reducing building energy consumption. In this study, the thermal and fluid dynamic performance of a solar chimney integrated into a residential building located in Bordj Bou Arréridj (Eastern Algeria) was investigated through a comprehensive numerical, predictive, and optimization framework. A transient mathematical model was developed to evaluate the influence of key geometric parameters, including chimney width and inlet opening width, as well as environmental factors such as solar radiation intensity and wind speed, on the system performance. The generated simulation database was subsequently employed to develop and compare four machine learning models, namely, Artificial Neural Networks with Bayesian Regularization (ANN-BR), Deep Neural Networks optimized by Improved Grey Wolf Optimization (DNN-IGWO), k-Nearest Neighbors (KNN), and Extreme Gradient Boosting (XGBoost), for predicting eight output parameters including glazing temperature, fluid temperature, absorber temperature, outlet temperature, thermal efficiency, air change rate (ACH), mass flow rate, and outlet velocity. The results demonstrated that increasing chimney and inlet widths significantly enhances ventilation performance by increasing airflow rate and ACH. Weather conditions and wind speed were also found to strongly affect thermal efficiency and buoyancy-driven airflow. Among the predictive models, XGBoost and DNN-IGWO exhibited the highest predictive accuracy, achieving coefficients of determination (R2) close to unity and very low prediction errors for all output variables, confirming their robustness and generalization capability. The proposed methodology provides a reliable tool for rapid performance prediction and design optimization of solar chimney systems under different climatic and operating conditions, thereby supporting the development of energy-efficient passive ventilation strategies for residential buildings. Full article
Show Figures

Figure 1

30 pages, 11402 KB  
Article
Hybrid Solar Tube System for Integrated Daylighting and Passive Ventilation: Design and Performance Assessment for Energy-Efficient Buildings
by Faris Alqurashi, Rached Nciri and Faouzi Nasri
Buildings 2026, 16(11), 2207; https://doi.org/10.3390/buildings16112207 - 30 May 2026
Cited by 1 | Viewed by 566
Abstract
This study presents the design and performance evaluation of a hybrid solar-driven system (SOLIVE) that integrates tubular daylighting and buoyancy-driven natural ventilation within a single architectural component for industrial and large-scale buildings. While solar tubes and solar chimneys have been widely studied as [...] Read more.
This study presents the design and performance evaluation of a hybrid solar-driven system (SOLIVE) that integrates tubular daylighting and buoyancy-driven natural ventilation within a single architectural component for industrial and large-scale buildings. While solar tubes and solar chimneys have been widely studied as independent passive technologies, their combined use in a unified system capable of delivering both daylight and ventilation remains largely unexplored. The proposed system utilizes solar tubes not only for transmitting natural daylight but also as thermal drivers that induce airflow through the stack effect generated by solar heating along the tube surface. A mathematical framework combining photometric daylight modeling and buoyancy-driven airflow analysis was developed to evaluate the system performance. Numerical simulations were conducted for three representative solar reference days (Equinox, Summer Solstice, and Winter Solstice). The influence of the key design parameters, including illuminated surface area (5–15 m2), solar tube diameter (0.1–0.3 m), and ventilated space volume (20–60 m3), was systematically analyzed. The results show that, under the adopted modelling assumptions, the system provides peak illuminance between 376 and 502 lux and ventilation rates up to 20.5 air changes per hour (ACH). These values are discussed as indicative benchmarks with respect to ISO 8995-1 and ASHRAE 62.1, rather than as proof of full real-building compliance, since glare, illuminance uniformity, thermal comfort, occupancy, wind effects and HVAC integration were not fully modelled. These findings demonstrate the potential of the proposed system as an effective passive solution for improving indoor environmental quality and reducing building energy demand in sunny climates. Full article
(This article belongs to the Special Issue Daylighting and Environmental Interactions in Building Design)
Show Figures

Figure 1

27 pages, 14936 KB  
Article
Experimentally Validated Discrete Phase Model for PM2.5 and PM10 with Numerical Transport Mapping
by Ren Paulo Estaquio, Ma Kevina Canlas, Neil Astrologo, Job Immanuel Encarnacion, Joshua Agar, Ken Bryan Fernandez, Julius Rhoan Lustro and Joseph Gerard Reyes
Fluids 2026, 11(4), 90; https://doi.org/10.3390/fluids11040090 - 29 Mar 2026
Cited by 2 | Viewed by 1043
Abstract
Indoor exposure to particulate matter (PM) depends on ventilation-driven transport, yet sensor placement in real rooms is often based on limited point data. This study develops and experimentally validates a transient CFD framework, using RANS airflow coupled with Lagrangian discrete phase tracking, to [...] Read more.
Indoor exposure to particulate matter (PM) depends on ventilation-driven transport, yet sensor placement in real rooms is often based on limited point data. This study develops and experimentally validates a transient CFD framework, using RANS airflow coupled with Lagrangian discrete phase tracking, to map PM2.5 and PM10 in a full-scale 2.0 × 3.0 × 2.5 m bedroom with a fixed, non-oscillating pedestal fan and an open window. Airflow was verified by grid independence and validated against 10-point velocity measurements (RMSE = 0.108 m·s−1). Incense experiments (≈31 min burn) provided PM time series over the first 60 min at 16 locations on two heights; emission rate, burning time, and air-change rate (1.96–5.39 ACH) were calibrated so that accepted models achieved aggregate R2 > 0.90. Spatial mapping on a 0.5 m grid shows that PM behavior is governed primarily by airflow-defined accumulation pockets rather than by source proximity alone. A near-source region consistently captured strong early-time peaks, whereas remote low-exchange pockets remained elevated during the decay phase. For PM2.5, the most persistent hotspot is a ceiling-adjacent recirculation pocket, while for PM10, gravitational settling shifted the dominant hotspots toward floor-layer, low-velocity regions. An exposure score combining normalized peak and time-averaged concentrations, interpreted together with particle-track persistence metrics, distinguished transiently traversed regions from true retention pockets. The results show that sensor placement should follow the monitoring objective: near-source regions are more responsive to peak events, ceiling pockets are more suitable for persistent PM2.5 monitoring, and floor hotspots are more critical for PM10. No single fixed sensor location adequately represents both particle sizes in the present bedroom and ventilation configuration. Full article
(This article belongs to the Special Issue CFD Applications in Environmental Engineering)
Show Figures

Figure 1

24 pages, 12273 KB  
Article
Application of Airfoil Arrays on Building Façades as a Passive Design Strategy to Improve Indoor Ventilation
by Ardalan Aflaki and Atiye Jarrahi
Architecture 2025, 5(3), 64; https://doi.org/10.3390/architecture5030064 - 18 Aug 2025
Cited by 1 | Viewed by 2542
Abstract
Natural ventilation could be established as an effective passive design strategy for increasing air changes per hour in a built environment. Modern air conditioning systems often fail to provide sufficient fresh air, potentially causing health issues for occupants. In contrast, natural ventilation offers [...] Read more.
Natural ventilation could be established as an effective passive design strategy for increasing air changes per hour in a built environment. Modern air conditioning systems often fail to provide sufficient fresh air, potentially causing health issues for occupants. In contrast, natural ventilation offers an effective alternative for maintaining sufficient indoor air quality in buildings. This study explores the application of grouped airfoil arrays on building façades as an innovative passive design to enhance the air change rate. Numerical simulations were conducted to analyze various airfoil configurations, determining the most effective design for building a façade. Three groups, including symmetrical, semi-symmetrical, and flat-bottomed grouped airfoils, were selected according to their aerodynamic properties and potential impacts on airflow dynamics. For this purpose, a typical high-rise residential building was selected as a case study for field measurement and CFD simulation. The results indicated that symmetrical airfoil arrays could increase the air changes per hour (ACH) up to 23 times per hour with a wind velocity of 0.37 m/s at 10 m above ground, whereas their bidirectional performance ensured stable airflow regardless of wind direction. Although semi-symmetrical airfoil arrays maximize air capture and induce beneficial turbulence, the ACH within a residential unit was boosted up to 16 times per hour under the same outdoor wind velocity conditions. The ACH was 14 times per hour for the flat-bottom airfoils, serving as a comparative baseline and providing insights into the performance advantages of more complex designs. Full article
Show Figures

Figure 1

23 pages, 1593 KB  
Article
Natural Ventilation Technique of uNVeF in Urban Residential Unit Through a Case Study
by Ming-Lun Alan Fong and Wai-Kit Chan
Urban Sci. 2025, 9(8), 291; https://doi.org/10.3390/urbansci9080291 - 25 Jul 2025
Cited by 3 | Viewed by 3460
Abstract
The present study was motivated by the need to enhance indoor air quality and reduce airborne disease transmission in dense urban environments where high-rise residential buildings face challenges in achieving effective natural ventilation. The problem lies in the lack of scalable and convenient [...] Read more.
The present study was motivated by the need to enhance indoor air quality and reduce airborne disease transmission in dense urban environments where high-rise residential buildings face challenges in achieving effective natural ventilation. The problem lies in the lack of scalable and convenient tools to optimize natural ventilation rate, particularly in urban settings with varying building heights. To address this, the scientific technique developed with an innovative metric, the urbanized natural ventilation effectiveness factor (uNVeF), integrates regression analysis of wind direction, velocity, air change rate per hour (ACH), window configurations, and building height to quantify ventilation efficiency. By employing a field measurement methodology, the measurements were conducted across 25 window-opening scenarios in a 13.9 m2 residential unit on the 35/F of a Hong Kong public housing building, supplemented by the Hellman Exponential Law with a site-specific friction coefficient (0.2907, R2 = 0.9232) to estimate the lower floor natural ventilation rate. The results confirm compliance with Hong Kong’s statutory 1.5 ACH requirement (Practice Note for Authorized Persons, Registered Structural Engineers, and Registered Geotechnical Engineers) and achieving a peak ACH at a uNVeF of 0.953 with 75% window opening. The results also revealed that lower floors can maintain 1.5 ACH with adjusted window configurations. Using the Wells–Riley model, the estimation results indicated significant airborne disease infection risk reductions of 96.1% at 35/F and 93.4% at 1/F compared to the 1.5 ACH baseline which demonstrates a strong correlation between ACH, uNVeF and infection risks. The uNVeF framework offers a practical approach to optimize natural ventilation and provides actionable guidelines, together with future research on the scope of validity to refine this technique for residents and developers. The implications in the building industry include setting up sustainable design standards, enhancing public health resilience, supporting policy frameworks for energy-efficient urban planning, and potentially driving innovation in high-rise residential construction and retrofitting globally. Full article
Show Figures

Figure 1

61 pages, 4626 KB  
Article
Integrating Occupant Behavior into Window Design: A Dynamic Simulation Study for Enhancing Natural Ventilation in Residential Buildings
by Mojgan Pourtangestani, Nima Izadyar, Elmira Jamei and Zora Vrcelj
Buildings 2025, 15(13), 2193; https://doi.org/10.3390/buildings15132193 - 23 Jun 2025
Cited by 2 | Viewed by 2515
Abstract
Predicted natural ventilation (NV) often diverges from actual performance in dwellings. This discrepancy arises in part because most design tools do not account for how occupants actually operate windows. This study aims to determine how window geometry and orientation should be adjusted when [...] Read more.
Predicted natural ventilation (NV) often diverges from actual performance in dwellings. This discrepancy arises in part because most design tools do not account for how occupants actually operate windows. This study aims to determine how window geometry and orientation should be adjusted when occupant behavior is considered. Survey data from 150 Melbourne residents were converted into two window-operation schedules: Same Behavior (SB), representing average patterns, and Probable Behavior (PB), capturing stochastic responses to comfort, privacy, and climate. Both schedules were embedded in EnergyPlus and applied to over 200 annual simulations across five window-design stories that varied orientations, placements, and window-to-wall ratios (WWRs). Each story was tested across two living room wall dimensions (7 m and 4.5 m) and evaluated for air-change rate per hour (ACH) and solar gains. PB increased annual ACH by 5–12% over SB, with the greatest uplift in north-facing cross-ventilated layouts on the wider wall. Integrating probabilistic occupant behavior into window design remarkably improves NV effectiveness, with peak summer ACH reaching 4.8, indicating high ventilation rates that support thermal comfort and improved IAQ without mechanical assistance. These results highlight the potential of occupant-responsive window configurations to reduce reliance on mechanical cooling and enhance indoor air quality (IAQ). This study contributes a replicable occupant-centered workflow and ready-to-apply design rules for Australian temperate climates, adapted to different climate zones. Future research will extend the method to different climates, housing types, and user profiles and will integrate smart-sensor feedback, adaptive glazing, and hybrid ventilation strategies through multi-objective optimization. Full article
Show Figures

Figure 1

31 pages, 14974 KB  
Article
3SqAir Project: A Living Lab Towards Sustainable Smart Strategy for Indoor Climate Quality Assurance in Classrooms
by James Ogundiran, Jean-Paul Kapuya Bulaba Nyembwe, John Omomoluwa Ogundiran, Ruben Alexandre de Souto Santos, Luísa Dias Pereira and Manuel Gameiro da Silva
Atmosphere 2025, 16(5), 584; https://doi.org/10.3390/atmos16050584 - 13 May 2025
Cited by 2 | Viewed by 1315
Abstract
The indoor climate quality in classrooms at the University of Coimbra, Portugal, was investigated as part of the 3SqAir project, supported by the Interreg SUDOE program. This research focused on two equipped classrooms with different ventilation systems: natural and mechanical ventilation. Both classrooms [...] Read more.
The indoor climate quality in classrooms at the University of Coimbra, Portugal, was investigated as part of the 3SqAir project, supported by the Interreg SUDOE program. This research focused on two equipped classrooms with different ventilation systems: natural and mechanical ventilation. Both classrooms were continuously monitored for IEQ parameters: thermal comfort, indoor air quality, noise, and lighting during heating and cooling seasons. Air temperature, relative humidity, CO2 concentration, particulate matter, nitrogen dioxide, volatile organic compounds, formaldehyde, sound pressure level, and illuminance were measured. Outdoor weather conditions were also recorded. The primary focus was on air temperature, CO2 concentrations, and relative humidity, while air change rates (ACH) were estimated using the Tracer Gas Method. The results showed inadequate thermal conditions in both classrooms, particularly during the heating season. Most weekly mean CO2 concentrations were within acceptable limits, while ACH were below standard recommendations in four CO2 decay phases. Simulations of CO2 decay revealed further air quality gaps in each room. Corrective measures within the 3SqAir project framework were suggested for approval and implementation while monitoring continues. This work represents the first phase in an evolving study towards developing sustainable strategies for improving indoor air quality in classrooms. Full article
(This article belongs to the Special Issue Modelling of Indoor Air Quality and Thermal Comfort)
Show Figures

Figure 1

24 pages, 8310 KB  
Article
Microclimate Air Motion and Uniformity of Indoor Plant Factory System: Effects of Crop Planting Density and Air Change Rate
by Han Gao, Zhi-Cheng Tan, Ming Yang, Cheng-Peng Ma, Yu-Fei Tang and Fu-Yun Zhao
Appl. Sci. 2025, 15(8), 4329; https://doi.org/10.3390/app15084329 - 14 Apr 2025
Cited by 4 | Viewed by 2175
Abstract
In a plant factory, maintaining proper and uniform air/moisture movement above the crop canopy is crucial for aiding plant growth. This research has utilized a three-dimensional computation model to investigate airflow and heat transfer in a plant factory, where airflow, heat, and humidity [...] Read more.
In a plant factory, maintaining proper and uniform air/moisture movement above the crop canopy is crucial for aiding plant growth. This research has utilized a three-dimensional computation model to investigate airflow and heat transfer in a plant factory, where airflow, heat, and humidity distributions above plant crops were calculated concerning five categories of crop planting density (Pd) and air change rate (ACH) in the crop area. Spatial uniformities of airflow velocity, temperature, and relative humidity immediately above the crops are evaluated using the objective uniformity parameter (OU), relative standard deviation of temperature (RSDT) and relative standard deviation of relative humidity (RSDRH), respectively. Furthermore, a factor of effectiveness (θ) is defined, depending on the uniformity of velocity, temperature, and relative humidity distribution, to comprehensively evaluate the impact of various ACH with Pd on overall effectiveness. Full numerical results show that air velocity, temperature, and relative humidity above the crops are notably influenced by Pd and ACH. As ACH increases, the OU of the air above the indoor crop also expands. Moreover, higher OU values are observed for smaller crop Pd. However, excessively small crop area planting densities and excessively large ACH do not result in a higher OU for the air above the crop. As ACH increases, both RSDT and RSDRH decay for the whole range of crop Pd. Moreover, smaller Pd values could achieve the uniformity of thermal fields, while having minimal effects on the relative humidity distributions. Generally, increasing ACH and decreasing Pd could enhance overall value of θ. However, excessively increasing ACH and decreasing Pd does not have a significant effect on θ, which is jointly influenced by OU, RSDT, and RSDRH. Therefore, a more suitable combination of ACH and Pd is urgently required to improve the design of agricultural system to enhance crop microclimate uniformity for optimal plant growth and productivity. Full article
(This article belongs to the Section Civil Engineering)
Show Figures

Figure 1

17 pages, 4269 KB  
Article
Optimising Air Change Rates: A CFD Study on Mitigating Pathogen Transmission in Aircraft Cabins
by Jaydon Benn and Lin Tian
Fluids 2025, 10(3), 74; https://doi.org/10.3390/fluids10030074 - 20 Mar 2025
Cited by 2 | Viewed by 2609
Abstract
Amid the COVID-19 pandemic, understanding airborne pathogen transmission within confined spaces became critically important. The release of infectious aerosols through activities such as breathing, speaking, and coughing poses significant health risks, especially in confined spaces like airplane cabins. This study addresses gaps in [...] Read more.
Amid the COVID-19 pandemic, understanding airborne pathogen transmission within confined spaces became critically important. The release of infectious aerosols through activities such as breathing, speaking, and coughing poses significant health risks, especially in confined spaces like airplane cabins. This study addresses gaps in the research by evaluating the impact of air changes per hour (ACH) on pathogen transmission in an aircraft cabin using computational fluid dynamics (CFD) simulations. A detailed computer-aided design (CAD) model representing half of a four-row section of a Boeing 737 cabin was developed, utilising symmetry boundary conditions to optimise the computational resources while maintaining accuracy. Using ANSYS Fluent 2024, four scenarios were simulated at ACH rates of 15, 20, 25, and 30, with 4 µm pathogens injected into the cabin from a single infector. Airflow patterns and pathogen residence times were analysed for each case. The results indicate that ACH 15 presents the highest risk of pathogen transmission, while increasing the ACH to 20 significantly reduces this risk, with diminishing returns observed beyond ACH 20. Thus, this study underscores the importance of balancing ventilation efficiency, energy consumption, and passenger comfort. The findings provide valuable insights into optimising the ventilation systems to mitigate the airborne transmission in aircraft cabins. Future research should explore higher ACH rates, validate their impact, and conduct a comprehensive optimisation study to further improve the infection control measures. Full article
(This article belongs to the Special Issue CFD Applications in Environmental Engineering)
Show Figures

Figure 1

31 pages, 9021 KB  
Article
Assessment of Floor-Level Impact on Natural Ventilation and Indoor Thermal Environment in Hot–Humid Climates: A Case Study of a Mid-Rise Educational Building
by Emeka J. Mba, Peter I. Oforji, Francis O. Okeke, Ikechukwu W. Ozigbo, Chinyelu D. F. Onyia, Chinelo A. Ozigbo, Emmanuel C. Ezema, Foluso C. Awe, Rosemary C. Nnaemeka-Okeke and Stephanie C. Onyia
Buildings 2025, 15(5), 686; https://doi.org/10.3390/buildings15050686 - 22 Feb 2025
Cited by 12 | Viewed by 6352
Abstract
The rapid urbanization of developing cities has intensified the challenge of maintaining thermal comfort in buildings, particularly in hot–humid climates. This study investigates the impact of floor level on airflow patterns and indoor temperatures in multi-purpose mid-rise buildings in Onitsha, Nigeria, where increasing [...] Read more.
The rapid urbanization of developing cities has intensified the challenge of maintaining thermal comfort in buildings, particularly in hot–humid climates. This study investigates the impact of floor level on airflow patterns and indoor temperatures in multi-purpose mid-rise buildings in Onitsha, Nigeria, where increasing urban density and frequent power outages necessitate effective passive cooling strategies. Through a mixed-method approach combining empirical measurements, computational fluid dynamics (CFD) simulations, and thermal performance analysis, the research examined variations in ventilation rates and temperature distributions across different floor levels of a six-story educational building over an annual cycle, focusing on the hottest (27 February), coldest (28 December), most windy (3 April), and least windy (17 September) days. Results revealed distinct floor-level ventilation patterns: upper floors (fourth–fifth) achieved 39–40 air changes per hour (ACH) during hot periods while maintaining temperatures of 30–35 degrees Celsius (°C); middle floors (second–third) showed moderate ventilation (15–22 ACH) but experienced heat accumulation (35–42 °C); and lower floors reached 20 ACH during windy conditions. Temperature stratification varied from 15 °C between floors across the entire building during peak conditions to 7 °C during windy periods. Stack-driven ventilation in upper floors contributed to temperature reductions of up to 3 °C, while wind-driven ventilation promoted uniform temperature distribution across all levels. These findings informed floor-specific design recommendations: hybrid ventilation systems with automated controls, strategic architectural features including a minimum floor level area of 15% for the central atrium, and comprehensive monitoring systems with six temperature sensors per floor. This study provides evidence-based strategies for optimizing thermal comfort in tropical urban environments, particularly valuable for designing energy-efficient buildings in rapidly developing cities with hot-humid climates. Full article
(This article belongs to the Special Issue Healthy, Low-Carbon and Resilient Built Environments)
Show Figures

Figure 1

25 pages, 8162 KB  
Article
Parametric Analysis of the Factors Impacting the Spatial Distribution of Particles in a Bus Environment
by Zeinab Bahman Zadeh, Bryan E. Cummings and L. James Lo
Sustainability 2025, 17(3), 1051; https://doi.org/10.3390/su17031051 - 27 Jan 2025
Cited by 1 | Viewed by 1906
Abstract
This study presents a parametric analysis of the factors impacting particle distribution within a bus environment using computational fluid dynamics (CFD) simulations, with a primary focus on the relative concentration (RC) of particles. The Novel Relative Concentration (RC) metric, which measures the deviation [...] Read more.
This study presents a parametric analysis of the factors impacting particle distribution within a bus environment using computational fluid dynamics (CFD) simulations, with a primary focus on the relative concentration (RC) of particles. The Novel Relative Concentration (RC) metric, which measures the deviation from a return concentration, was used to assess the effects of ventilation rates, the number and spatial arrangement of particle emitters, and thermal conditions. Our investigation reveals that increasing air changes per hour (ACHs) from 5.74 h−1 to 28.66 h−1 reduces the overall particle concentration by approximately 45%, but localized high concentration zones persist, with maximum RC values observed at 1.57. Scenarios with evenly distributed emitters achieved near-uniform particle distribution, with RC values averaging around 0.95, while clustered emitters resulted in localized high concentrations, with RC values exceeding 2.0. Thermal conditions were found to have a minimal effect on RC, with average values of 1.664 for cooling and 1.588 for heating, showing only a 4.68% difference. The RC metric provided clear insights into the non-uniformity of particle distribution, highlighting areas prone to higher concentrations, with some zones reaching RC values of 2.5, indicating concentrations 2.5 times higher than the well-mixed average. These findings underscore the importance of optimizing ventilation systems for both overall air exchange and uniform air distribution, offering practical implications for improving air quality and reducing the risk of airborne pathogen transmission in public transportation systems. Future research should explore real-time ventilation adjustments based on passenger load, the effects of different particle types, and the development of models incorporating human behavior and movement patterns. Full article
Show Figures

Figure 1

20 pages, 5032 KB  
Article
Energy Losses or Savings Due to Air Infiltration and Envelope Sealing Costs in the Passivhaus Standard: A Review on the Mediterranean Coast
by Víctor Echarri-Iribarren, Ricardo Gómez-Val and Iñigo Ugalde-Blázquez
Buildings 2024, 14(7), 2158; https://doi.org/10.3390/buildings14072158 - 13 Jul 2024
Cited by 5 | Viewed by 2917
Abstract
To obtain the Passivhaus Certificate or Passivhaus Standard (PHS), requirements regarding building envelope air tightness must be met: according to the n50 parameter, at a pressure of 50 Pa, air leakage must be below 0.6 air changes per hour (ACH). This condition [...] Read more.
To obtain the Passivhaus Certificate or Passivhaus Standard (PHS), requirements regarding building envelope air tightness must be met: according to the n50 parameter, at a pressure of 50 Pa, air leakage must be below 0.6 air changes per hour (ACH). This condition is verified by following the blower door test protocol and is regulated by the ISO 9972 standard, or UNE-EN-13829. Some construction techniques make it easier to comply with these regulations, and in most cases, construction joints and material joints must be sealed in a complex way, both on façades and roofs and at ground contact points. Performing rigorous quality control of these processes during the construction phase allows achieving a value below 0.6 ACH and obtaining the PHS certification. Yet, the value can increase substantially with the passage of time: as windows and doors are used, opened, or closed; as envelope materials expand; with humidity; etc. This could result in significant energy consumption increases and losing the PHS when selling the house at a later point in time. It is therefore important to carefully supervise the quality of the construction and its execution. In this study, we focused on a house located in Sitges (Barcelona). The envelope air tightness quality was measured during four construction phases, together with the sealing of the joints and service ducts. The blower door test was performed in each phase, and the n50 value obtained decreased each time. The execution costs of each phase were also determined, as were the investment amortisation rates based on the consequent annual energy demand reductions. Air infiltration dropped by 43.81%, with the final n50 value resulting in 0.59 ACH. However, the execution costs—EUR 3827—were high compared to the energy savings made, and the investment amortisation period rose to a 15- to 30-year range. To conclude, these airtightness improvements are necessary in cold continental climates but are not applicable on the Spanish Mediterranean coast. Full article
(This article belongs to the Special Issue Research on the Airtightness of Buildings)
Show Figures

Figure 1

24 pages, 9734 KB  
Article
Impact of Diffuser Location on Thermal Comfort Inside a Hospital Isolation Room
by Mustafa Alkhalaf, Adrian Ilinca, Mohamed Yasser Hayyani and Fahed Martini
Designs 2024, 8(2), 19; https://doi.org/10.3390/designs8020019 - 20 Feb 2024
Cited by 5 | Viewed by 3912
Abstract
Thermal comfort is increasingly recognized as vital in healthcare facilities, where patients spend 80–90% of their time indoors. Sensing, controlling, and predicting indoor air quality should be monitored for thermal comfort. This study examines the effects of ventilation design on thermal comfort in [...] Read more.
Thermal comfort is increasingly recognized as vital in healthcare facilities, where patients spend 80–90% of their time indoors. Sensing, controlling, and predicting indoor air quality should be monitored for thermal comfort. This study examines the effects of ventilation design on thermal comfort in hospital rooms, proposing four distinct ventilation configurations, each with three airflow rates of 9, 12, and 15 Air Changes per Hour (ACH). The study conducted various ventilation simulation scenarios for a hospital room. The objective is to determine the effect of airflow and the diffuser location distribution on thermal comfort. The Reynolds-Averaged Navier–Stokes (RANS) equations, along with the k–ε turbulence model, were used as the underlying mathematical representation for the airflow. The boundary conditions for the simulations were derived from the ventilation standards set by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) and insights from previous studies. Thermal comfort and temperature distribution were assessed using indices like Predicted Percentage Dissatisfaction (PPD), Predicted Mean Vote (PMV), and Air Diffusion Performance Index (ADPI). Although most of the twelve scenarios failed to attain thermal comfort, two of those instances were optimal in this simulation. Those instances involved the return diffuser behind the patient and airflow of 9 ACH, the minimum recommended by previous studies. It should be noted that the ADPI remained unmet in these cases, revealing complexities in achieving ideal thermal conditions in healthcare environments. This study extends the insights from our prior research, advancing our understanding of ventilation impacts on thermal comfort in healthcare facilities. It underscores the need for comprehensive approaches to environmental control, setting the stage for future research to refine these findings further. Full article
(This article belongs to the Topic Building Energy and Environment, 2nd Edition)
Show Figures

Figure 1

21 pages, 3721 KB  
Article
Enhancing Indoor Air Quality and Regulatory Compliance: An In-Depth Comparative Study on Ventilation Strategies and Their Impact on SARS-CoV-2 Transmission Risk
by Atefeh Abbaspour, Ali Bahadori-Jahromi, Alan Janbey, Paulina B. Godfrey and Shiva Amirkhani
Sustainability 2024, 16(1), 271; https://doi.org/10.3390/su16010271 - 27 Dec 2023
Cited by 10 | Viewed by 4560
Abstract
Enclosed-space ventilation plays a pivotal role in enhancing indoor air quality (IAQ). Various regulations and guidelines determine minimum fresh air requirements, varying by the application, country, etc. The present study employs real-time indoor CO2 measurements to calculate the actual air change rate [...] Read more.
Enclosed-space ventilation plays a pivotal role in enhancing indoor air quality (IAQ). Various regulations and guidelines determine minimum fresh air requirements, varying by the application, country, etc. The present study employs real-time indoor CO2 measurements to calculate the actual air change rate (ACH) and models the building’s compliance with Chartered Institution of Building Services Engineers (CIBSE) guidelines to assess its impact on IAQ. The contaminant considered is the SARS-CoV-2 virus with multiple infectors, and the study calculates the virus’s transmission risk under different scenarios. Fresh air is assumed to be provided by mechanical or hybrid ventilation. The results reveal that the current building conditions are unacceptable, showing a significant gap from the recommended guideline rates. Meeting CIBSE recommendations ensures indoor air safety in terms of CO2 concentration. However, in extreme conditions with five infectors, findings show a 14% reduction in mechanical ventilation efficacy. Among the hybrid ventilation scenarios, combining CIBSE rates with natural ventilation, with a 30% door and window opening from the class outset, proves most effective in reducing the virus’s transmission risk, with a 58–70% reduction from the building’s current condition. Furthermore, implementing supplementary measures like air cleaners resulted in an additional 28–50% reduction in transmission risk. Full article
Show Figures

Figure 1

18 pages, 7302 KB  
Article
Evaluation of Actual Ventilation Rates and Efficiency in Research-Scale Pig Houses Based on Ventilation Configurations
by Se-yeon Lee, Lak-yeong Choi, Jinseon Park, Kehinde Favour Daniel, Se-woon Hong, Kyeongseok Kwon and Okhwa Hwang
Animals 2023, 13(15), 2451; https://doi.org/10.3390/ani13152451 - 29 Jul 2023
Cited by 5 | Viewed by 3370
Abstract
Accurate ventilation control is crucial for maintaining a healthy and productive environment in research-specialized pig facilities. This study aimed to evaluate actual ventilation rates and ventilation efficiency by investigating different inlet and exhaust configurations. The research was conducted in two pig rooms, namely [...] Read more.
Accurate ventilation control is crucial for maintaining a healthy and productive environment in research-specialized pig facilities. This study aimed to evaluate actual ventilation rates and ventilation efficiency by investigating different inlet and exhaust configurations. The research was conducted in two pig rooms, namely pig room A and pig room B, in the absence of animals and workers to focus solely on evaluating the ventilation system’s performance. Actual ventilation rates were measured using hood-type anemometers, and the local air change per hour was analyzed at various measurement points via tracer gas decay experiments. The results demonstrated that specific inlet and exhaust combinations, such as side inlet/chimney outlet and ceiling inlet/side outlet, exhibited higher ventilation rates. However, the measured ventilation rates were much lower than the manufacturer’s specifications. The side exhaust fan closer to the pig activity space demonstrated better ventilation effectiveness for the animals than the chimney exhaust fan. Additionally, the ceiling inlet exhibited superior air distribution and uniformity. Lower ventilation rates and higher infiltration ratios resulted in reduced ventilation efficiency, with the difference between pig and worker activity spaces being pronounced. This study emphasizes the importance of selecting optimal inlet and exhaust configurations to achieve efficient ventilation and create a healthy environment for both pigs and workers. Full article
(This article belongs to the Section Animal System and Management)
Show Figures

Figure 1

Back to TopTop