Next Article in Journal
Factors Determining Buying Behavior on the Organic Food Market in the Visegrad Group Countries—Using Canonical Correlation Analysis
Previous Article in Journal
Relational Resources, Digital Capability, and Value Proposition Innovation: Impact on Entrepreneurial Performance in Chinese Snack Enterprises
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effect of Ventilation Strategies of Center-Mounted Louver Ventilation Window on Building Energy Consumption and Daylighting

1
College of Architecture and Urban Planning, Qingdao University of Technology, Qingdao 266033, China
2
School of Environmental and Municipal Engineering, Jilin Jianzhu University, Changchun 130118, China
*
Author to whom correspondence should be addressed.
Sustainability 2025, 17(2), 670; https://doi.org/10.3390/su17020670
Submission received: 18 December 2024 / Revised: 13 January 2025 / Accepted: 14 January 2025 / Published: 16 January 2025

Abstract

An innovative center-mounted louver ventilation window suitable for seasonal ventilation strategies was proposed, combining the regional climate of Qingdao. The sustainable development concept is embodied, which can not only reduce building energy consumption but also consider the quality of daylighting. This research constructed a comprehensive evaluation framework, taking an office building in Qingdao as an example. The framework utilized the parametric design platform Grasshopper and its environmental design plug-in Ladybugtools. It considered the daylighting performance and energy consumption of the building. This study included six different ventilation strategies, with energy use intensity and useful daylight illuminance as evaluation indicators. The results indicated that the seasonal ventilation strategies and parameters of blinds were optimized to significantly improve the energy efficiency of the building without compromising daylighting quality. The optimized solution reduces energy consumption from 83.81 kWh/m2 to 55.0 kWh/m2, achieving a 34.4% reduction while maintaining a high UDI. This energy-saving effect reveals the influence of different ventilation strategies on energy and daylighting. And it provides an important reference for sustainable design in similar climate contexts.
Keywords: center-mounted louver ventilation window; ventilation strategies; energy consumption; daylighting; sustainable building design center-mounted louver ventilation window; ventilation strategies; energy consumption; daylighting; sustainable building design

Share and Cite

MDPI and ACS Style

Ma, Q.; Ma, H.; Wan, Z.; Wang, Z.; Wei, X. Effect of Ventilation Strategies of Center-Mounted Louver Ventilation Window on Building Energy Consumption and Daylighting. Sustainability 2025, 17, 670. https://doi.org/10.3390/su17020670

AMA Style

Ma Q, Ma H, Wan Z, Wang Z, Wei X. Effect of Ventilation Strategies of Center-Mounted Louver Ventilation Window on Building Energy Consumption and Daylighting. Sustainability. 2025; 17(2):670. https://doi.org/10.3390/su17020670

Chicago/Turabian Style

Ma, Qingsong, Hao Ma, Ziwei Wan, Zhen Wang, and Xindong Wei. 2025. "Effect of Ventilation Strategies of Center-Mounted Louver Ventilation Window on Building Energy Consumption and Daylighting" Sustainability 17, no. 2: 670. https://doi.org/10.3390/su17020670

APA Style

Ma, Q., Ma, H., Wan, Z., Wang, Z., & Wei, X. (2025). Effect of Ventilation Strategies of Center-Mounted Louver Ventilation Window on Building Energy Consumption and Daylighting. Sustainability, 17(2), 670. https://doi.org/10.3390/su17020670

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop