Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (129)

Search Parameters:
Keywords = whole cell biosensors

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
23 pages, 2366 KiB  
Article
Whole-Cell Fiber-Optic Biosensor for Real-Time, On-Site Sediment and Water Toxicity Assessment: Applications at Contaminated Sites Across Israel
by Gal Carmeli, Abraham Abbey Paul, Kathelina Kristollari, Evgeni Eltzov, Albert Batushansky and Robert S. Marks
Biosensors 2025, 15(7), 404; https://doi.org/10.3390/bios15070404 - 22 Jun 2025
Viewed by 1235
Abstract
Sediments are key players in the optimum functioning of ecosystems; however, they also represent the largest known repository of harmful contaminants. The vast variety of these sediment-associated contaminants may exert harmful effects on marine communities and can impair ecosystem functioning. Whole-cell biosensors are [...] Read more.
Sediments are key players in the optimum functioning of ecosystems; however, they also represent the largest known repository of harmful contaminants. The vast variety of these sediment-associated contaminants may exert harmful effects on marine communities and can impair ecosystem functioning. Whole-cell biosensors are a rapid and biologically relevant tool for assessing environmental toxicity. Therefore, in this study, we developed a bioassay-based toxicity measurement system using genetically modified bacteria to create a whole-cell optical biosensor. Briefly, reporter bacteria were integrated and immobilized using a calcium alginate matrix on fiber-optic tips connected to a photon counter placed inside a light-proof, portable case. The calcium alginate matrix acts as a semi-permeable membrane that protects the reporter-encapsulated optical fiber tips and allows the inward passage of toxicant(s) to induce a dose-dependent response in the bioreporter. The samples were tested by directly submerging the fiber tip with immobilized bacteria into vials containing either water or suspended sediment samples, and the subsequent bioluminescent responses were acquired. In addition to bioavailable sediment toxicity assessments, conventional chemical methods, such as liquid chromatography–mass spectroscopy (LC-MS) and inductively coupled plasma optical emission spectroscopy (ICP-OES), were used for comprehensive evaluation. The results demonstrated the efficacy of the biosensor in detecting various toxicity levels corresponding to identified contaminants, highlighting its potential integration into environmental monitoring frameworks for enhanced sediment and water quality assessments. Despite its utility, this study notes the system’s operational challenges in field conditions, recommending future enhancements for improved portability and usability in remote locations. Full article
(This article belongs to the Special Issue Optical Biosensors for Environmental Monitoring)
Show Figures

Figure 1

24 pages, 5306 KiB  
Article
Cellular Mechanical Phenotypes of Drought-Resistant and Drought-Sensitive Rice Species Distinguished by Double-Resonator Piezoelectric Cytometry Biosensors
by Ding Tang, Tiean Zhou, Weisong Pan, Shimei Wang and Muhammad Ahmad Hassan
Biosensors 2025, 15(6), 334; https://doi.org/10.3390/bios15060334 - 23 May 2025
Viewed by 478
Abstract
Various high-throughput screening methods have been developed to explore plant phenotypes, primarily at the organ and whole plant levels. There is a need to develop phenomics methods at the cellular level to narrow down the genotype to phenotype gap. This study used double-resonator [...] Read more.
Various high-throughput screening methods have been developed to explore plant phenotypes, primarily at the organ and whole plant levels. There is a need to develop phenomics methods at the cellular level to narrow down the genotype to phenotype gap. This study used double-resonator piezoelectric cytometry biosensors to capture the dynamic changes in mechanical phenotypes of living cells of two rice species, drought-resistant Lvhan No. 1 and drought-sensitive 6527, under PEG6000 drought stress. In rice cells of Lvhan No. 1 and 6527, mechanomics parameters, including cell-generated surface stress (ΔS) and viscoelastic parameters (G′, G″, G″/G′), were measured and compared under 5–25% PEG6000. Lvhan No. 1 showed larger viscoelastic but smaller surface stress changes with the same concentration of PEG6000. Moreover, Lvhan No. 1 cells showed better wall–plasma membrane–cytoskeleton continuum structure maintaining ability under drought stress, as proven by transient tension stress (ΔS > 0) and linear G′~ΔS, G″~ΔS relations at higher 15–25% PEG6000, but not for 6527 cells. Additionally, two distinct defense and drought resistance mechanisms were identified through dynamic G″/G′ responses: (i) transient hardening followed by softening recovery under weak drought, and (ii) transient softening followed by hardening recovery under strong drought. The abilities of Lvhan No. 1 cells to both recover from transient hardening to softening and to recover from transient softening to hardening are better than those of 6527 cells. Overall, the dynamic mechanomics phenotypic patterns (ΔS, G′, G″, G″/G′, G′~ΔS, G″~ΔS) verified that Lvhan No. 1 has better drought resistance than that of 6527, which is consistent with the field data. Full article
(This article belongs to the Section Biosensor and Bioelectronic Devices)
Show Figures

Figure 1

16 pages, 2642 KiB  
Article
Optimizing Whole-Cell Biosensors for the Early Detection of Crop Infections: A Proof-of-Concept Study
by Nadav Zanger and Evgeni Eltzov
Biosensors 2025, 15(5), 300; https://doi.org/10.3390/bios15050300 - 8 May 2025
Cited by 1 | Viewed by 491
Abstract
This study presents a proof-of-concept evaluation of optimized whole-cell biosensors designed for the real-time detection of crop infections. Genetically engineered luminescent bacterial strains were used to detect volatile organic compounds (VOCs) emitted by crops during spoilage. Key factors investigated include bacterial uniformity, nutrient [...] Read more.
This study presents a proof-of-concept evaluation of optimized whole-cell biosensors designed for the real-time detection of crop infections. Genetically engineered luminescent bacterial strains were used to detect volatile organic compounds (VOCs) emitted by crops during spoilage. Key factors investigated include bacterial uniformity, nutrient supply, and temperature effects. The results demonstrated that lower temperatures (+4 °C) yielded higher sensor sensitivity and prolonged bacterial viability. A proof-of-concept evaluation was conducted in storage-like conditions, showing effective infection detection in potatoes. These findings underscore the potential of whole-cell-based biosensors for monitoring postharvest production in cold storage environments. Full article
(This article belongs to the Section Biosensor and Bioelectronic Devices)
Show Figures

Figure 1

54 pages, 21736 KiB  
Review
Whole Cells of Microorganisms—A Powerful Bioanalytical Tool for Measuring Integral Parameters of Pollution: A Review
by Maxim Cheliukanov, George Gurkin, Roman Perchikov, Anastasia Medvedeva, Tatyana Lavrova, Tatyana Belousova, Aleksandra Titova, Yulia Plekhanova, Sergei Tarasov, Anna Kharkova, Vyacheslav Arlyapov, Philippe Mandin, Hideaki Nakamura and Anatoly Reshetilov
Biosensors 2025, 15(5), 290; https://doi.org/10.3390/bios15050290 - 4 May 2025
Viewed by 1225
Abstract
Microbial biosensors are bioanalytical devices that can measure the toxicity of pollutants or detect specific substances. This is the greatest advantage of microbial biosensors which use whole cells of microorganisms as powerful tools for measuring integral parameters of environmental pollution. This review explores [...] Read more.
Microbial biosensors are bioanalytical devices that can measure the toxicity of pollutants or detect specific substances. This is the greatest advantage of microbial biosensors which use whole cells of microorganisms as powerful tools for measuring integral parameters of environmental pollution. This review explores the core principles of microbial biosensors including biofuel devices, emphasizing their capacity to evaluate biochemical oxygen demand (BOD), toxicity, heavy metals, surfactants, phenols, pesticides, inorganic pollutants, and microbiological contamination. However, practical challenges, such as sensitivity to environmental factors like pH, salinity, and the presence of competing substances, continue to hinder their broader application and long-term stability. The performance of these biosensors is closely tied to both technological advancement and the scientific understanding of biological systems, which influence data interpretation and device optimization. The review further examines cutting-edge developments, including the integration of electroactive biofilms with nanomaterials, molecular biology techniques, and artificial intelligence, all of which significantly enhance biosensor functionality and analytical accuracy. Commercial implementations and improvement strategies are also discussed, providing a comprehensive overview of the state-of-the-art in this field. Overall, this work consolidates recent progress and identifies both the potential and limitations of microbial biosensors, offering valuable insights into their future development for environmental monitoring. Full article
(This article belongs to the Special Issue Microbial Biosensor: From Design to Applications—2nd Edition)
Show Figures

Graphical abstract

16 pages, 2711 KiB  
Article
Ultrasensitive Peptide-Based Electrochemical Biosensor for Universal Diagnostic of Dengue
by Isis Campos Prado, João Pedro Rangel da Silva Carvalho, André Souza Araujo, Paloma Napoleão-Pêgo and Salvatore Giovanni De-Simone
Biosensors 2025, 15(4), 236; https://doi.org/10.3390/bios15040236 - 8 Apr 2025
Viewed by 905
Abstract
Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, [...] Read more.
Dengue is a neglected disease mainly affecting tropical and subtropical countries. The diagnosis of dengue fever is still a problem since most of it is made from whole or recombinant DENV proteins, which present cross-reactions with other members of the Flavivirus family. Therefore, there is still a huge demand for new diagnostic methods that provide rapid, low-cost, easy-to-use confirmation. Thus, in this study, we developed an affordable electrochemical biosensor for rapidly detecting immunoglobulin G (IgG) serological antibodies in the sera of DENV-infected patients. An identified linear B-cell epitope (DENV/18) specific for DENV 1–4 serotypes recognized by IgG in patient sera was selected as a target molecule after a microarray of peptides using the SPOT-synthesis methodology. After chemical synthesis, the DENV/18-peptide was immobilized on the surface of the working electrode of a commercially available screen-printed gold electrode (SPGE). The capture of DENV-specific IgG allowed for the formation of an immunocomplex that was measured by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) using a potassium ferrocyanide/ferricyanide ([Fe(CN)6]3−/4−) electrochemical probe. An evaluation of the biosensor’s performance showed a detection limit of 100 µg mL−1 for the synthetic peptides (DENV/18) and 1.21 ng mL−1 in CV and 0.43 ng mL−1 in DPV for human serum, with a sensitivity of 7.21 µA in CV and 8.79 µA in DPV. The differentiation of infected and uninfected individuals was possible even at a high dilution factor that reduced the required sample volumes to a few microliters. The final device proved suitable for diagnosing DENV by analyzing real serum samples, and the results showed good agreement with molecular biology diagnostics. The flexibility to conjugate other antigenic peptides to SPEs suggests that this technology could be rapidly adapted to diagnose other pathogens. Full article
(This article belongs to the Special Issue Biosensing and Diagnosis—2nd Edition)
Show Figures

Graphical abstract

13 pages, 1448 KiB  
Perspective
Bioluminescent Microbial Bioreporters: A Personal Perspective
by Shimshon Belkin
Biosensors 2025, 15(2), 111; https://doi.org/10.3390/bios15020111 - 14 Feb 2025
Cited by 3 | Viewed by 1079
Abstract
This review attempts to summarize my three decades-long involvement in, and contribution to, the design, construction and testing of bioluminescent microbial sensor strains (bioreporters). With the understanding that such a document cannot be completely free of bias, the review focuses on studies from [...] Read more.
This review attempts to summarize my three decades-long involvement in, and contribution to, the design, construction and testing of bioluminescent microbial sensor strains (bioreporters). With the understanding that such a document cannot be completely free of bias, the review focuses on studies from my own lab only, with almost no coverage of the parallel progress made by others in similar fields. This admittedly subjective approach by no way detracts from the achievements of countless excellent researchers who are not mentioned here, and whose contributions to the field are at least as important as that of my own. The review covers basic aspects of microbial sensor design, and then progresses to describe approaches to performance improvement of sensor strains aimed at the detection of either specific chemicals, groups of chemicals sharing similar characteristics, or global effects, such as toxicity and genotoxicity. The need for integration of live sensor cells into a compatible hardware platform is highlighted, as is the importance of long-term maintenance of the cells’ viability and activity. The use of multi-member sensors’ panels is presented as a means for enhancing the detection spectrum and sample “fingerprinting”, along with a list of different purposes to which such sensors have been put to use. Full article
Show Figures

Figure 1

29 pages, 4900 KiB  
Article
Physicochemical Rationale of Matrix Effects Involved in the Response of Hydrogel-Embedded Luminescent Metal Biosensors
by Elise Rotureau, Christophe Pagnout and Jérôme F. L. Duval
Biosensors 2024, 14(11), 552; https://doi.org/10.3390/bios14110552 - 13 Nov 2024
Viewed by 1394
Abstract
There is currently a critical need for understanding how the response and activity of whole-cell bacterial reporters positioned in a complex biological or environmental matrix are impacted by the physicochemical properties of their micro-environment. Accordingly, a comprehensive analysis of the bioluminescence response of [...] Read more.
There is currently a critical need for understanding how the response and activity of whole-cell bacterial reporters positioned in a complex biological or environmental matrix are impacted by the physicochemical properties of their micro-environment. Accordingly, a comprehensive analysis of the bioluminescence response of Cd(II)-inducible PzntA-luxCDABE Escherichia coli biosensors embedded in silica-based hydrogels is reported to decipher how metal bioavailability, cell photoactivity and ensuing light bioproduction are impacted by the hydrogel environment and the associated matrix effects. The analysis includes the account of (i) Cd speciation and accumulation in the host hydrogels, in connection with their reactivity and electrostatic properties, and (ii) the reduced bioavailability of resources for the biosensors confined (deep) inside the hydrogels. The measurements of the bioluminescence response of the Cd(II) inducible-lux biosensors in both hydrogels and free-floating cell suspensions are completed by those of the constitutive rrnB P1-luxCDABE E. coli so as to probe cell metabolic activity in these two situations. The approach contributes to unraveling the connections between the electrostatic hydrogel charge, the nutrient/metal bioavailabilities and the resulting Cd-triggered bioluminescence output. Biosensors are hosted in hydrogels with thickness varying between 0 mm (the free-floating cell situation) and 1.6 mm, and are exposed to total Cd concentrations from 0 to 400 nM. The partitioning of bioavailable metals at the hydrogel/solution interface following intertwined metal speciation, diffusion and Boltzmann electrostatic accumulation is addressed by stripping chronopotentiometry. In turn, we detail how the bioluminescence maxima generated by the Cd-responsive cells under all tested Cd concentration and hydrogel thickness conditions collapse remarkably well on a single plot featuring the dependence of bioluminescence on free Cd concentration at the individual cell level. Overall, the construction of this master curve integrates the contributions of key and often overlooked processes that govern the bioavailability properties of metals in 3D matrices. Accordingly, the work opens perspectives for quantitative and mechanistic monitoring of metals by biosensors in environmental systems like biofilms or sediments. Full article
(This article belongs to the Section Environmental Biosensors and Biosensing)
Show Figures

Graphical abstract

12 pages, 1852 KiB  
Article
Development of an Escherichia coli Cell-Based Biosensor for Aspirin Monitoring by Genetic Engineering of MarR
by Yeonhong Kim, Yangwon Jeon, Kyeoungseok Song, Haekang Ji, Soon-Jin Hwang and Youngdae Yoon
Biosensors 2024, 14(11), 547; https://doi.org/10.3390/bios14110547 - 12 Nov 2024
Cited by 1 | Viewed by 1661
Abstract
Multiple antibiotic resistance regulators (MarRs) control the transcription of genes in the mar operon of Escherichia coli in the presence of salicylic acid (SA). The interaction with SA induces conformational changes in the MarR released from the promoter of the mar operon, turning [...] Read more.
Multiple antibiotic resistance regulators (MarRs) control the transcription of genes in the mar operon of Escherichia coli in the presence of salicylic acid (SA). The interaction with SA induces conformational changes in the MarR released from the promoter of the mar operon, turning on transcription. We constructed an SA-specific E. coli cell-based biosensor by fusing the promoter of the mar operon (PmarO) and the gene that encodes an enhanced green fluorescent protein (egfp). Because SA and aspirin are structurally similar, a biosensor for monitoring aspirin can be obtained by genetically engineering MarR to be aspirin (ASP)-responsive. To shift the selectivity of MarR toward ASP, we changed the residues around the ligand-binding sites by site-directed mutagenesis. We examined the effects of genetic engineering on MarR by introducing MarRs with PmarO-egfp into E. coli. Among the tested mutants, MarR T72A improved the ASP responses by approximately 3 times compared to the wild-type MarR, while still showing an SA response. Although the MarR T72A biosensor exhibited mutual interference between SA and ASP, it accurately determined the ASP concentration in spiked water and medicine samples with over 90% accuracy. While the ASP biosensors still require improvement, our results provide valuable insights for developing E. coli cell-based biosensors for ASP and transcription factor-based biosensors in general. Full article
(This article belongs to the Special Issue Cell-Based Biosensors for Rapid Detection and Monitoring)
Show Figures

Figure 1

11 pages, 3509 KiB  
Article
Quantitative Chemical Sensing Using Genetically Engineered Bacterial Bioreporters
by Yonatan Uziel, Yossef Kabessa, Benjamin Shemer, Etai Shpigel, Shimshon Belkin and Aharon J. Agranat
Chemosensors 2024, 12(10), 207; https://doi.org/10.3390/chemosensors12100207 - 11 Oct 2024
Cited by 1 | Viewed by 1246
Abstract
We present a generic quantitative chemical sensing methodology for assessing the concentration of a target material (TM) in an aqueous solution by using bioluminescent microbial bioreporters as the core sensing elements. Such bioreporters, genetically engineered to respond to the presence of a TM [...] Read more.
We present a generic quantitative chemical sensing methodology for assessing the concentration of a target material (TM) in an aqueous solution by using bioluminescent microbial bioreporters as the core sensing elements. Such bioreporters, genetically engineered to respond to the presence of a TM in their microenvironment by emitting bioluminescence, have previously been mostly designed to report the presence or absence of the TM in the sample. We extend this methodology to also assess the TM concentration, by exploiting the dose-dependency of the TM-induced luminescence. To overcome luminescence intensity variations due to bacterial batch differences and the ambient temperature, simultaneous measurements were carried out on sample solutions containing known concentrations of the TM. A “standard ratio” parameter, defined as the ratio between the two measurements, is shown to be independent of the bacterial batch and the temperature, and hence provides the conceptual basis for a generic quantitative chemical sensing methodology. Assessment of 2,4-dinitrotoluene (DNT) concentration in solutions is demonstrated with an accuracy of 2.5% over a wide dynamic range. Full article
Show Figures

Figure 1

12 pages, 3242 KiB  
Article
Electrochemical Impedance Spectroscopy-Based Microfluidic Biosensor Using Cell-Imprinted Polymers for Bacteria Detection
by Shiva Akhtarian, Satinder Kaur Brar and Pouya Rezai
Biosensors 2024, 14(9), 445; https://doi.org/10.3390/bios14090445 - 18 Sep 2024
Cited by 6 | Viewed by 2115
Abstract
The rapid and sensitive detection of bacterial contaminants using low-cost and portable point-of-need (PoN) biosensors has gained significant interest in water quality monitoring. Cell-imprinted polymers (CIPs) are emerging as effective and inexpensive materials for bacterial detection as they provide specific binding sites designed [...] Read more.
The rapid and sensitive detection of bacterial contaminants using low-cost and portable point-of-need (PoN) biosensors has gained significant interest in water quality monitoring. Cell-imprinted polymers (CIPs) are emerging as effective and inexpensive materials for bacterial detection as they provide specific binding sites designed to capture whole bacterial cells, especially when integrated into PoN microfluidic devices. However, improving the sensitivity and detection limits of these sensors remains challenging. In this study, we integrated CIP-functionalized stainless steel microwires (CIP-MWs) into a microfluidic device for the impedimetric detection of E. coli bacteria. The sensor featured two parallel microchannels with three-electrode configurations that allowed simultaneous control and electrochemical impedance spectroscopy (EIS) measurements. A CIP-MW and a non-imprinted polymer (NIP)-MW suspended perpendicular to the microchannels served as the working electrodes in the test and control channels, respectively. Electrochemical spectra were fitted with equivalent electrical circuits, and the charge transfer resistances of both cells were measured before and after incubation with target bacteria. The charge transfer resistance of the CIP-MWs after 30 min of incubation with bacteria was increased. By normalizing the change in charge transfer resistance and analyzing the dose–response curve for bacterial concentrations ranging from 0 to 107 CFU/mL, we determined the limits of detection and quantification as 2 × 102 CFU/mL and 1.4 × 104 CFU/mL, respectively. The sensor demonstrated a dynamic range of 102 to 107 CFU/mL, where bacterial counts were statistically distinguishable. The proposed sensor offers a sensitive, cost-effective, durable, and rapid solution for on-site identification of waterborne pathogens. Full article
Show Figures

Figure 1

16 pages, 14127 KiB  
Article
2PP-Hydrogel Covered Electrodes to Compensate for Media Effects in the Determination of Biomass in a Capillary Wave Micro Bioreactor
by Sven Meinen, Steffen Brinkmann, Kevin Viebrock, Bassant Elbardisy, Henning Menzel, Rainer Krull and Andreas Dietzel
Biosensors 2024, 14(9), 438; https://doi.org/10.3390/bios14090438 - 9 Sep 2024
Viewed by 1512
Abstract
Microbioreactors increase information output in biopharmaceutical screening applications because they can be operated in parallel without consuming large quantities of the pharmaceutical formulations being tested. A capillary wave microbioreactor (cwMBR) has recently been reported, allowing cost-efficient parallelization in an array that can be [...] Read more.
Microbioreactors increase information output in biopharmaceutical screening applications because they can be operated in parallel without consuming large quantities of the pharmaceutical formulations being tested. A capillary wave microbioreactor (cwMBR) has recently been reported, allowing cost-efficient parallelization in an array that can be activated for mixing as a whole. Although impedance spectroscopy can directly distinguish between dead and viable cells, the monitoring of cells in suspension within bioreactors is challenging because the signal is influenced by the potentially varying properties of the culture medium. In order to address this challenge, an impedance sensor consisting of two sets of microelectrodes in a cwMBR is presented. Only one set of electrodes was covered by a two-photon cross-linked hydrogel to become insensitive to the influence of cells while remaining sensitive to the culture medium. With this impedance sensor, the biomass of Saccharomyces cerevisiae could be measured in a range from 1 to 20 g L−1. In addition, the sensor can compensate for a change in the conductivity of the suspension of 5 to 15 mS cm−1. Moreover, the two-photon cross-linking of hydroxyethyl starch methacrylate hydrogel, which has been studied in detail, recommends itself for even much broader sensing applications in miniaturized bioreactors and biosensors. Full article
(This article belongs to the Special Issue MEMS Based Biosensors and Its Applications)
Show Figures

Graphical abstract

9 pages, 3799 KiB  
Communication
The Assessment of Methyl Methanesulfonate Absorption by Amphipods from the Environment Using Lux-Biosensors
by Uliana S. Novoyatlova, Anna A. Kudryavtseva, Sergey V. Bazhenov, Anna A. Utkina, Vadim V. Fomin, Shamil A. Nevmyanov, Bagila S. Zhoshibekova, Maria A. Fedyaeva, Mikhail Y. Kolobov and Ilya V. Manukhov
Biosensors 2024, 14(9), 427; https://doi.org/10.3390/bios14090427 - 5 Sep 2024
Cited by 4 | Viewed by 1705
Abstract
The ability of aquatic mesofauna representatives involved in trophic chains to sorb and accumulate toxicants is important for understanding the functioning of aquatic ecosystems and for fishing industry. This study investigated the capacity of marine amphipod Gammarus oceanicus and freshwater amphipods Eulimnogammarus vittatus [...] Read more.
The ability of aquatic mesofauna representatives involved in trophic chains to sorb and accumulate toxicants is important for understanding the functioning of aquatic ecosystems and for fishing industry. This study investigated the capacity of marine amphipod Gammarus oceanicus and freshwater amphipods Eulimnogammarus vittatus and Gammarus lacustris to absorb the DNA-alkylating agent methyl methanesulfonate (MMS). The presence of alkylating agents in the environment and in the tissues of the amphipods was determined using whole-cell lux-biosensor Escherichia coli MG1655 pAlkA-lux, in which the luxCDABE genes from Photorhabdus luminescens, enabling the luminescence of the cell culture, are controlled by the PalkA promoter of DNA glycosylase. It was shown that within one day of incubation in water containing MMS at a concentration above 10 μM, the amphipods absorbed the toxicant and their tissues produce more alkylation damage to biosensor cells than the surrounding water. Concentrations of MMS above 1 mM in the environment caused the death of the amphipods before the toxicant could be significantly concentrated in their tissues. The sensitivity and the capacity to absorb MMS were found to be approximately the same for the marine amphipod G. oceanicus and the freshwater amphipods E. vittatus and G. lacustris. Full article
(This article belongs to the Section Environmental Biosensors and Biosensing)
Show Figures

Figure 1

22 pages, 8826 KiB  
Article
Microbead-Encapsulated Luminescent Bioreporter Screening of P. aeruginosa via Its Secreted Quorum-Sensing Molecules
by Abraham Abbey Paul, Yael Schlichter Kadosh, Ariel Kushmaro and Robert S. Marks
Biosensors 2024, 14(8), 383; https://doi.org/10.3390/bios14080383 - 8 Aug 2024
Cited by 3 | Viewed by 2728
Abstract
Pseudomonas aeruginosa is an opportunistic Gram-negative bacterium that remains a prevalent clinical and environmental challenge. Quorum-sensing (QS) molecules are effective biomarkers in pinpointing the presence of P. aeruginosa. This study aimed to develop a convenient-to-use, whole-cell biosensor using P. aeruginosa reporters individually [...] Read more.
Pseudomonas aeruginosa is an opportunistic Gram-negative bacterium that remains a prevalent clinical and environmental challenge. Quorum-sensing (QS) molecules are effective biomarkers in pinpointing the presence of P. aeruginosa. This study aimed to develop a convenient-to-use, whole-cell biosensor using P. aeruginosa reporters individually encapsulated within alginate-poly-L-lysine (alginate-PLL) microbeads to specifically detect the presence of bacterial autoinducers. The PLL-reinforced microbeads were prepared using a two-step method involving ionic cross-linking and subsequent coating with thin layers of PLL. The alginate-PLL beads showed good stability in the presence of a known cation scavenger (sodium citrate), which typically limits the widespread applications of calcium alginate. In media containing synthetic autoinducers—such as N-(3-oxo dodecanoyl) homoserine lactone (3-oxo-C12-HSL) and N-butanoyl-L-homoserine lactone (C4-HSL), or the cell-free supernatants of planktonic or the flow-cell biofilm effluent of wild P. aeruginosa (PAO1)—the encapsulated bacteria enabled a dose-dependent detection of the presence of these QS molecules. The prepared bioreporter beads remained stable during prolonged storage at 4 and −80 °C and were ready for on-the-spot sensing without the need for recovery. The proof-of-concept, optical fiber-based, and whole-cell biosensor developed here demonstrates the practicality of the encapsulated bioreporter for bacterial detection based on specific QS molecules. Full article
Show Figures

Figure 1

41 pages, 3245 KiB  
Review
Recent Advances in Biosensor Technology for Early-Stage Detection of Hepatocellular Carcinoma-Specific Biomarkers: An Overview
by Raja Chinnappan, Tariq Makhzoum, Momo Arai, Amro Hajja, Farah Abul Rub, Ibrahim Alodhaibi, Mohammed Alfuwais, Muhammad Affan Elahi, Eman Abdullah Alshehri, Lohit Ramachandran, Naresh Kumar Mani, Shugufta Abrahim, Mohammad Shabab Mir, Khaled Al-Kattan, Tanveer Ahmad Mir and Ahmed Yaqinuddin
Diagnostics 2024, 14(14), 1519; https://doi.org/10.3390/diagnostics14141519 - 15 Jul 2024
Cited by 3 | Viewed by 3680
Abstract
Hepatocellular carcinoma is currently the most common malignancy of the liver. It typically occurs due to a series of oncogenic mutations that lead to aberrant cell replication. Most commonly, hepatocellular carcinoma (HCC) occurs as a result of pre-occurring liver diseases, such as hepatitis [...] Read more.
Hepatocellular carcinoma is currently the most common malignancy of the liver. It typically occurs due to a series of oncogenic mutations that lead to aberrant cell replication. Most commonly, hepatocellular carcinoma (HCC) occurs as a result of pre-occurring liver diseases, such as hepatitis and cirrhosis. Given its aggressive nature and poor prognosis, the early screening and diagnosis of HCC are crucial. However, due to its plethora of underlying risk factors and pathophysiologies, patient presentation often varies in the early stages, with many patients presenting with few, if any, specific symptoms in the early stages. Conventionally, screening and diagnosis are performed through radiological examination, with diagnosis confirmed by biopsy. Imaging modalities tend to be limited by their requirement of large, expensive equipment; time-consuming operation; and a lack of accurate diagnosis, whereas a biopsy’s invasive nature makes it unappealing for repetitive use. Recently, biosensors have gained attention for their potential to detect numerous conditions rapidly, cheaply, accurately, and without complex equipment and training. Through their sensing platforms, they aim to detect various biomarkers, such as nucleic acids, proteins, and even whole cells extracted by a liquid biopsy. Numerous biosensors have been developed that may detect HCC in its early stages. We discuss the recent updates in biosensing technology, highlighting its competitive potential compared to conventional methodology and its prospects as a tool for screening and diagnosis. Full article
(This article belongs to the Special Issue Recent Advancements of Molecular Biomarkers in Cancer)
Show Figures

Figure 1

29 pages, 1672 KiB  
Review
Whole-Cell Biosensor for Iron Monitoring as a Potential Tool for Safeguarding Biodiversity in Polar Marine Environments
by Marzia Calvanese, Caterina D’Angelo, Maria Luisa Tutino and Concetta Lauro
Mar. Drugs 2024, 22(7), 299; https://doi.org/10.3390/md22070299 - 28 Jun 2024
Viewed by 4600
Abstract
Iron is a key micronutrient essential for various essential biological processes. As a consequence, alteration in iron concentration in seawater can deeply influence marine biodiversity. In polar marine environments, where environmental conditions are characterized by low temperatures, the role of iron becomes particularly [...] Read more.
Iron is a key micronutrient essential for various essential biological processes. As a consequence, alteration in iron concentration in seawater can deeply influence marine biodiversity. In polar marine environments, where environmental conditions are characterized by low temperatures, the role of iron becomes particularly significant. While iron limitation can negatively influence primary production and nutrient cycling, excessive iron concentrations can lead to harmful algal blooms and oxygen depletion. Furthermore, the growth of certain phytoplankton species can be increased in high-iron-content environments, resulting in altered balance in the marine food web and reduced biodiversity. Although many chemical/physical methods are established for inorganic iron quantification, the determination of the bio-available iron in seawater samples is more suitably carried out using marine microorganisms as biosensors. Despite existing challenges, whole-cell biosensors offer other advantages, such as real-time detection, cost-effectiveness, and ease of manipulation, making them promising tools for monitoring environmental iron levels in polar marine ecosystems. In this review, we discuss fundamental biosensor designs and assemblies, arranging host features, transcription factors, reporter proteins, and detection methods. The progress in the genetic manipulation of iron-responsive regulatory and reporter modules is also addressed to the optimization of the biosensor performance, focusing on the improvement of sensitivity and specificity. Full article
Show Figures

Figure 1

Back to TopTop