Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (73)

Search Parameters:
Keywords = resonant photoacoustic spectroscopy

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
25 pages, 1075 KB  
Review
The Role of Tumor pH in Breast Cancer Imaging: Biology, Diagnostic Applications, and Emerging Techniques
by Dyutika Kantamneni, Saumya Gurbani and Mary Salvatore
Diagnostics 2026, 16(1), 76; https://doi.org/10.3390/diagnostics16010076 - 25 Dec 2025
Viewed by 847
Abstract
Breast cancer screening, while vital for reducing mortality, faces significant limitations in sensitivity and specificity, particularly in dense breasts. Current modalities primarily detect anatomical changes, often missing biologically aggressive tumors at their earliest stages. The altered metabolism of cancer cells establishes a characteristic [...] Read more.
Breast cancer screening, while vital for reducing mortality, faces significant limitations in sensitivity and specificity, particularly in dense breasts. Current modalities primarily detect anatomical changes, often missing biologically aggressive tumors at their earliest stages. The altered metabolism of cancer cells establishes a characteristic inverted pH gradient that drives tumor invasion, metastasis, and treatment resistance. This makes tumor acidity a compelling, functional biomarker for early detection. This review synthesizes the emerging role of pH as a diagnostic biomarker and provides a critical evaluation of advanced imaging techniques for its non-invasive or minimal measurement. We detail the biological underpinnings of tumor acidosis, emphasizing its regulation through glycolytic reprogramming and dysregulated proton transport. Our analysis encompasses a broad spectrum of pH-sensitive imaging modalities, including magnetic resonance methods such as Chemical Exchange Saturation Transfer (CEST) MRI for extracellular pH mapping and multi-nuclear Magnetic Resonance Spectroscopy (MRS) using 1H, 31P, and 19F nuclei to probe various cellular compartments. Furthermore, we examine hyperpolarized 13C MRI for real-time metabolic flux imaging, where metrics such as the lactate-to-pyruvate ratio demonstrate significant predictive value for treatment response. The review also assesses optical and photoacoustic imaging techniques, which offer high sensitivity but are often constrained to superficial tumors. Imaging tumor pH provides a powerful functional window into the earliest metabolic shifts in breast cancer, far preceding macroscopic anatomical changes. The ongoing development and evidence support the role of the pH-sensitive imaging techniques in diagnosis, lesion characterization, and therapy. Additionally, it holds promise for supplementing breast cancer screening by enabling earlier, more specific detection and personalized risk stratification, ultimately aiming to improve patient outcomes. Full article
(This article belongs to the Special Issue Advances in Breast Diagnostics)
Show Figures

Figure 1

20 pages, 3452 KB  
Article
Highly Sensitive Online Detection of Acetylene in Transformer Oil Using Photoacoustic Spectroscopy
by Fuxing Cui, Mingjun Nie, Ting Chen and Ming Xu
Electronics 2025, 14(24), 4907; https://doi.org/10.3390/electronics14244907 - 13 Dec 2025
Viewed by 338
Abstract
To meet the demand for online monitoring of acetylene (C2H2) in transformer oil, a high-sensitivity detection system based on photoacoustic spectroscopy (PAS) is presented. The system integrates custom-designed modules for signal acquisition, phase-sensitive detection, and data processing, centered around [...] Read more.
To meet the demand for online monitoring of acetylene (C2H2) in transformer oil, a high-sensitivity detection system based on photoacoustic spectroscopy (PAS) is presented. The system integrates custom-designed modules for signal acquisition, phase-sensitive detection, and data processing, centered around a high-performance microcontroller. A full-wave lock-in amplification-based phase-sensitive detection circuit enables precise extraction of nV-level photoacoustic signals. Finite element simulations of the resonant photoacoustic cell in COMSOL 6.2 were conducted to optimize the structural configuration and sensor placement, achieving maximum acoustic response. Calibration experiments confirmed excellent system performance, demonstrating a linear response (R2 > 0.99) over the 0.5–20 ppm range and a practical detection limit of 0.1 ppm. Comparative evaluations against conventional dissolved gas analysis (DGA) equipment verify the system’s sensitivity, stability, and temporal resolution, demonstrating its potential as a high-sensitivity and reliable solution for transformer fault gas diagnostics. Full article
Show Figures

Figure 1

14 pages, 1887 KB  
Article
Enhancing Robustness in Photoacoustic Detection of Dissolved Acetylene in Transformer Oil: Temperature Effects on Resonance Frequency and Suppression Using the Perturbation Observation Method
by Heli Ni, Jiajia Wang, Xinye Wu, Jinxuan Song, Zhicheng Wu, Lin He and Qiaogen Zhang
Energies 2025, 18(24), 6512; https://doi.org/10.3390/en18246512 - 12 Dec 2025
Viewed by 276
Abstract
Photoacoustic spectroscopy is a promising method for detecting dissolved acetylene (C2H2) in transformer oil, facilitating early fault diagnosis in power transformers. However, temperature variations significantly influence the resonance frequency of the photoacoustic cell, potentially reducing detection accuracy. This study [...] Read more.
Photoacoustic spectroscopy is a promising method for detecting dissolved acetylene (C2H2) in transformer oil, facilitating early fault diagnosis in power transformers. However, temperature variations significantly influence the resonance frequency of the photoacoustic cell, potentially reducing detection accuracy. This study investigates the temperature effects on the first-order longitudinal acoustic mode of a resonant photoacoustic cell using finite element simulations with thermo-viscous acoustics. The results show that as the temperature increases, the resonant frequency increases linearly and the sound pressure amplitude decreases, consistent with analytical models. To enhance system robustness, a perturbation observation method is proposed, treating operating frequency as the independent variable and acoustic pressure as the dependent variable. Time-domain simulations validate its effectiveness in tracking resonance frequency shifts under varying temperatures, ensuring reliable detection. Future work should focus on improving frequency resolution, noise filtering, and adaptive step-size optimization for practical applications. Full article
Show Figures

Figure 1

10 pages, 1118 KB  
Communication
A Compact Highly Sensitive Cone–Sphere Photoacoustic Spectroscopy Sensor for Real-Time Detection of Dissolved Acetylene in Transformer Oil
by Jiao Yang and Yazhou Liu
Photonics 2025, 12(12), 1208; https://doi.org/10.3390/photonics12121208 - 8 Dec 2025
Viewed by 1285
Abstract
In this work, we report a compact and highly sensitive photoacoustic spectroscopy (PAS) system based on a cone–sphere coupled photoacoustic cell (CSC-PAC) for real-time detection of trace acetylene (C2H2) dissolved in transformer oil. The sensing module integrates a conical [...] Read more.
In this work, we report a compact and highly sensitive photoacoustic spectroscopy (PAS) system based on a cone–sphere coupled photoacoustic cell (CSC-PAC) for real-time detection of trace acetylene (C2H2) dissolved in transformer oil. The sensing module integrates a conical resonator with a spherical cavity, forming a hybrid structure that effectively enhances photoacoustic confinement and energy coupling efficiency. Finite element thermo-viscoelastic simulations were employed to optimize the cavity geometry and resonance conditions for maximum signal generation. Experimental results demonstrate a strong linear correlation between the photoacoustic signal and C2H2 concentration (R2 > 0.999), with a sensitivity of 2.45 µV·ppm−1. Allan deviation confirms a detection limit of 18.6 ppb is achieved at a 400 s averaging time, confirming excellent system stability. The miniaturized light-acoustic spectroscopy sensor, with a total volume of 7.5 mL and a rapid response time of 25.5 s, provides a high-performance and field-deployable platform for on-site monitoring of high-voltage power equipment and other industrial applications. Full article
Show Figures

Figure 1

18 pages, 18184 KB  
Article
Photoacoustic Gas Sensing Using a Novel Fluidic Microphone Based on Thermal MEMS
by Akash Gupta, Anant Bhardwaj, Achim Bittner and Alfons Dehé
Sensors 2025, 25(24), 7411; https://doi.org/10.3390/s25247411 - 5 Dec 2025
Viewed by 1777
Abstract
Photoacoustic spectroscopy (PAS) is a powerful technique for selective gas detection; however, its performance in non-resonant configurations is fundamentally constrained by the poor low-frequency response of conventional acoustic detectors. Commercial MEMS microphones, although compact and cost effective, exhibit limited infrasound sensitivity, which restricts [...] Read more.
Photoacoustic spectroscopy (PAS) is a powerful technique for selective gas detection; however, its performance in non-resonant configurations is fundamentally constrained by the poor low-frequency response of conventional acoustic detectors. Commercial MEMS microphones, although compact and cost effective, exhibit limited infrasound sensitivity, which restricts the development of truly miniaturised and broadband PAS systems. To address this limitation, we present a novel MEMS fluidic microphone (f-mic) that operates on a thermal sensing principle and is explicitly optimised for the infrasound regime. The sensor demonstrates a constant sensitivity of 32 μV/Pa for frequencies below 20 Hz. A detailed analytical model incorporating frequency-dependent effects is developed to identify and investigate the critical design parameters that influence system performance. The overall system exhibits a band-pass frequency response, enabling broadband operation. Based on these insights, a miniaturised photoacoustic cell is fabricated, ensuring efficient optical coupling and f-mic integration. Experimental validation using a CO2-targeted laser system demonstrates a linear response up to 5000 ppm, a sensitivity of 6 nV/ppm, and a theoretical detection limit of 300 ppb over 100 s, resulting in an NNEA of 6×106 W cm−1 Hz−0.5. These results establish the f-mic as a robust, scalable solution for non-resonant PAS, effectively overcoming a significant bottleneck in compact gas sensing technologies. Full article
Show Figures

Figure 1

12 pages, 804 KB  
Article
Integrating Photon-Based Techniques to Probe Structural and Phonon Dynamics in Bacterial Cellulose
by Levente Csóka and Bunsho Ohtani
Polymers 2025, 17(18), 2544; https://doi.org/10.3390/polym17182544 - 20 Sep 2025
Viewed by 542
Abstract
Bacterial cellulose, a biopolymer synthesised by microorganisms, exhibits remarkable structural, optical, and electronic properties. This study utilised a range of photon- and electron-based techniques, including X-ray diffraction, proton nuclear magnetic resonance (1H-NMR), photoacoustic spectroscopy, and scanning electron microscopy, to thoroughly characterise [...] Read more.
Bacterial cellulose, a biopolymer synthesised by microorganisms, exhibits remarkable structural, optical, and electronic properties. This study utilised a range of photon- and electron-based techniques, including X-ray diffraction, proton nuclear magnetic resonance (1H-NMR), photoacoustic spectroscopy, and scanning electron microscopy, to thoroughly characterise BC. While XRD and NMR directly employ photons to probe the structure and composition, PAS indirectly converts absorbed photons into phonons to evaluate optoelectronic features. SEM revealed a dense nanofibrillar network with fibrils measuring 10–75 nm in diameter. XRD confirmed the crystalline nature of BC, identifying characteristic peaks associated with cellulose Iα. 1H-NMR relaxation analysis differentiated between the ordered and disordered cellulose regions. PAS determined an optical bandgap of 2.97 eV and identified defect states between 3.6 and 2.9 eV, including a prominent peak at 3.35 eV, likely resulting from oxygen vacancies, hydroxyl modifications, or UV-induced rearrangements. These defects modify BC’s electronic structure, suggesting potential for bandgap engineering. The integration of these complementary techniques provides a multidimensional understanding of BC’s morphology, crystallinity, and electronic behaviour, underscoring its potential in bioelectronics, advanced composites, and biomedical applications. Full article
(This article belongs to the Special Issue Advances in Cellulose-Based Polymers and Composites, 2nd Edition)
Show Figures

Figure 1

11 pages, 2829 KB  
Article
Low-Cost, LED-Based Photoacoustic Spectrophone Using Hemispherical Acoustic Resonant Cavity for Measurement of Hydrocarbon Gases
by Gaoxuan Wang, Lingxiao Hou, Fangjun Li, Lihui Wang, Chao Fei, Xiaojian Hong and Sailing He
Atmosphere 2025, 16(9), 1012; https://doi.org/10.3390/atmos16091012 - 28 Aug 2025
Viewed by 929
Abstract
Spherical acoustic resonant cavities have been increasingly reported in photoacoustic spectroscopy due to their small volume and enhanced effective gas absorption path length. For further reducing the acoustic cavity volume and exploiting broadband LED as a light source, this paper reports a low-cost, [...] Read more.
Spherical acoustic resonant cavities have been increasingly reported in photoacoustic spectroscopy due to their small volume and enhanced effective gas absorption path length. For further reducing the acoustic cavity volume and exploiting broadband LED as a light source, this paper reports a low-cost, LED-based photoacoustic gas-sensing system using a hemispherical acoustic resonant (HAR) cavity with a radius of 15 mm and a volume of 7.07 mL. The placement of both the excitation light source and transducer, as important elements in photoacoustic spectroscopy, was systematically optimized for improving the generation efficient of photoacoustic signal. The frequency response of the HAR cavity was thoroughly characterized for exploring an optimal operation frequency of the light source. Through positional and frequency optimization, the developed low-cost, LED-based photoacoustic spectrophone realized highly sensitive measurements of hydrocarbon gases with measurement sensitivities of 111.6 ppm (3σ) for isobutane, 140.1 ppm (3σ) for propane, and 866.4 ppm (3σ) for ethylene at an integration time of 1 s. These results demonstrate the strong potential of low-cost, LED-HAR-based PA-sensing systems in the field of gas sensing for widespread deployment in distributed sensor networks and atmospheric monitoring platforms. Full article
Show Figures

Figure 1

12 pages, 3116 KB  
Article
Dual-Component Beat-Frequency Quartz-Enhanced Photoacoustic Spectroscopy Gas Detection System
by Hangyu Xu, Yiwen Feng, Zihao Chen, Zhenzhao Zhuang, Jinbao Xia, Yiyang Zhao and Sasa Zhang
Photonics 2025, 12(8), 747; https://doi.org/10.3390/photonics12080747 - 24 Jul 2025
Viewed by 1624
Abstract
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting [...] Read more.
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting the transient response of the quartz tuning fork (QTF) to acquire gas concentrations while concurrently capturing the QTF resonant frequency and quality factor in real-time. Owing to the short beat period and rapid system response, this approach significantly reduces time-delay constraints in time-division measurements, eliminating the need for periodic calibration inherent in conventional methods and preventing detection interruptions. The experimental results demonstrate minimum detection limits of 5.69 ppm for methane and 0.60 ppm for acetylene. Both gases exhibited excellent linear responses over the concentration range of 200 ppm to 4000 ppm, with the R2 value for methane being 0.996 and for acetylene being 0.997. The system presents a viable solution for the real-time, calibration-free monitoring of dissolved gases in transformer oil. Full article
(This article belongs to the Special Issue Advances in Optical Fiber Sensing Technology)
Show Figures

Figure 1

23 pages, 4894 KB  
Article
Evaluating Copper-Induced Oxidative Stress in Germinating Wheat Seeds Using Laser Photoacoustic Spectroscopy and EPR Techniques
by Mioara Petrus, Cristina Popa, Ana-Maria Bratu, Alexandra Camelia Joita and Vasile Bercu
Toxics 2025, 13(7), 604; https://doi.org/10.3390/toxics13070604 - 18 Jul 2025
Viewed by 1352
Abstract
Copper is an essential micronutrient for plants, but excessive levels can induce toxicity and impair physiological functions. This study evaluates the toxic effects of copper sulfate (CuSO4) on the germination of common wheat (Triticum aestivum), with emphasis on the [...] Read more.
Copper is an essential micronutrient for plants, but excessive levels can induce toxicity and impair physiological functions. This study evaluates the toxic effects of copper sulfate (CuSO4) on the germination of common wheat (Triticum aestivum), with emphasis on the gas emission dynamics and oxidative stress biomarkers. Seeds were germinated in agar and exposed to CuSO4 at concentrations of 1 µM, 100 µM, 1 mM, and 10 mM; distilled water served as the control. Ethylene and ammonia emissions were quantified using CO2 laser photoacoustic spectroscopy, while electron paramagnetic resonance (EPR) spectroscopy was employed to detect free radicals and Cu2+ complexes. Exposure to Cu concentrations ≥ 1 mM significantly inhibited germination and biomass accumulation. Enhanced ethylene and ammonia emissions, particularly at 10 mM, indicated stress-related metabolic responses. The EPR spectra confirmed the presence of semiquinone radicals and Cu2+ complexes under higher Cu levels. These results demonstrate that photoacoustic and EPR techniques are effective tools for the early detection of metal-induced phytotoxicity and offer a non-invasive approach to environmental toxicity screening and plant stress assessment. Full article
Show Figures

Graphical abstract

10 pages, 1296 KB  
Article
High-Sensitivity Dynamic Detection of Dissolved Acetylene in Transformer Oil Based on High-Power Quartz-Enhanced Photoacoustic Spectroscopy Sensing System
by Yuxiang Wu, Tiehua Ma, Chenhua Liu, Yashan Fan, Shuai Shi, Songjie Guo, Yu Wang, Xiangjun Xu, Guqing Guo, Xuanbing Qiu, Zhijin Shang and Chuanliang Li
Photonics 2025, 12(7), 713; https://doi.org/10.3390/photonics12070713 - 16 Jul 2025
Cited by 2 | Viewed by 1017
Abstract
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with [...] Read more.
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with an optimized acoustic resonator to enhance the acoustic signal. The laser power was boosted to 150 mW using a C-band erbium-doped fiber amplifier (EDFA), achieving a detection limit of 469 ppb for C2H2 with an integration time of 1 s. The headspace degassing method was utilized to extract dissolved gases from the transformer oil, and the equilibrium process for the release of dissolved C2H2 was successfully monitored using the developed high-power QEPAS system. This approach provides reliable technical support for the real-time monitoring of the operational safety of power transformers. Full article
(This article belongs to the Section Lasers, Light Sources and Sensors)
Show Figures

Figure 1

14 pages, 4011 KB  
Article
The Optimization of a T-Cell Resonator: Towards Highly Sensitive Photoacoustic Spectroscopy for Noninvasive Blood Glucose Detection
by Thasin Mohammad Zaman, Md Rejvi Kaysir, Shazzad Rassel and Dayan Ban
Biosensors 2025, 15(4), 254; https://doi.org/10.3390/bios15040254 - 16 Apr 2025
Viewed by 1217
Abstract
Noninvasive blood glucose monitoring is crucial for diabetes management, and photoacoustic spectroscopy (PAS) offers a promising solution by detecting glucose levels through human skin. However, weak acoustic signals in PAS systems require optimized resonator designs for enhanced detection sensitivity. Designing such resonators physically [...] Read more.
Noninvasive blood glucose monitoring is crucial for diabetes management, and photoacoustic spectroscopy (PAS) offers a promising solution by detecting glucose levels through human skin. However, weak acoustic signals in PAS systems require optimized resonator designs for enhanced detection sensitivity. Designing such resonators physically is complex, requiring the precise identification of critical parameters before practical implementation. This study focused on optimizing a T-shaped photoacoustic resonator using finite element modeling in a COMSOL Multiphysics environment. By systematically varying the geometric design parameters of the T-cell resonator, a maximum increase in the pressure amplitude of 12.76 times with a quality factor (Q-factor) of 47.5 was achieved compared to the previously designed reference acoustic resonator. This study took a significant step forward by identifying key geometric parameters that influence resonator performance, paving the way for more sensitive and reliable noninvasive glucose monitoring systems. Full article
(This article belongs to the Section Optical and Photonic Biosensors)
Show Figures

Figure 1

11 pages, 1240 KB  
Article
Calibration of a Quartz Tuning Fork as a Sound Detector
by Judith Falkhofen and Marcus Wolff
Appl. Sci. 2025, 15(7), 3655; https://doi.org/10.3390/app15073655 - 26 Mar 2025
Viewed by 829
Abstract
This study compares the performance of a quartz tuning fork (QTF) with a highly sensitive ultrasound microphone in the context of acoustic measurements, applying the substitution calibration method. QTF sensors are increasingly used for high-precision tasks due to their sensitivity and stability, while [...] Read more.
This study compares the performance of a quartz tuning fork (QTF) with a highly sensitive ultrasound microphone in the context of acoustic measurements, applying the substitution calibration method. QTF sensors are increasingly used for high-precision tasks due to their sensitivity and stability, while microphones are still the standard in general acoustic measurements. The aim of this study is to evaluate both technologies across several key performance metrics, including linearity of response, sensitivity, noise characteristics, and acoustic detection limit. Which sensor is better suited to which acoustic and physical condition? The results show that QTFs perform exceptionally well in applications requiring high precision, especially in high-frequency and narrow-band measurements. The signal-to-noise-ratio (SNR) of the QTF at its resonance frequency is 14 dB higher than that of the microphone, whereas the detection limit and linearity are comparable. The findings suggest that QTF sensors are particularly advantageous for specialized applications like photoacoustic spectroscopy (PAS). Full article
(This article belongs to the Special Issue Application of Ultrasonic Non-destructive Testing)
Show Figures

Figure 1

10 pages, 3418 KB  
Article
Off-Beam Acoustic Micro-Resonator for QEPAS Sensor with a Custom Quartz Tuning Fork
by Yong Wang, Gang Wang, Jiapeng Wang, Chaofan Feng, Qingyuan Tian, Yifan Chen, Ruyue Cui, Hongpeng Wu and Lei Dong
Atmosphere 2025, 16(3), 352; https://doi.org/10.3390/atmos16030352 - 20 Mar 2025
Cited by 4 | Viewed by 1131
Abstract
Quartz-enhanced photoacoustic spectroscopy (QEPAS) has shown great promise for monitoring greenhouse gases and pollutants with a high measurement accuracy and limit of detection. A QEPAS sensor, which can achieve high photoacoustic signal gain without requiring the laser beam to pass through the two [...] Read more.
Quartz-enhanced photoacoustic spectroscopy (QEPAS) has shown great promise for monitoring greenhouse gases and pollutants with a high measurement accuracy and limit of detection. A QEPAS sensor, which can achieve high photoacoustic signal gain without requiring the laser beam to pass through the two prongs of a quartz tuning fork (QTF), is reported. A custom QTF with a resonant frequency of 7.2 kHz and a quality factor of 8406 was employed as a sound detection element, and the parameters of the acoustic micro-resonator (AmR) in the off-beam QEPAS spectrophone were optimized. A signal-to-noise ratio (SNR) gain of 16 was achieved based on the optimal AmR dimensions compared to the bare custom QTF. Water vapor (H2O) was detected utilizing the QEPAS sensor equipped with the off-beam spectrophone, achieving a minimum detection limit (MDL) of 4 ppm with a normalized noise equivalent absorption coefficient (NNEA) of 5.7 × 10−8 cm−1·W·Hz−1/2 at an integration time of 300 ms. Full article
(This article belongs to the Special Issue New Insights into Photoacoustic Spectroscopy and Its Applications)
Show Figures

Figure 1

18 pages, 13729 KB  
Article
Design of NO2 Photoacoustic Detection System Based on Finite Element Simulation
by Long Wu, Tao Chen, Biao Xiang and Likun Xing
Appl. Sci. 2024, 14(23), 11343; https://doi.org/10.3390/app142311343 - 5 Dec 2024
Viewed by 1231
Abstract
Based on photoacoustic spectroscopy and finite element simulation technology, a simulation model of sound field excitation in a cylindrical resonant photoacoustic cell was established. The finite element simulation method was used to analyze the acoustic mode and sound pressure distribution of the cavity [...] Read more.
Based on photoacoustic spectroscopy and finite element simulation technology, a simulation model of sound field excitation in a cylindrical resonant photoacoustic cell was established. The finite element simulation method was used to analyze the acoustic mode and sound pressure distribution of the cavity structure of the photoacoustic cell. The effects of the geometric parameters of the resonator and the buffer cavity on the performance of the photoacoustic cell were compared. The frequency response characteristics of the photoacoustic cell and the effects of the air intake and the air outlet were studied. Based on the simulation results, a cylindrical resonant photoacoustic cell was designed, and a photoacoustic sensor for NO2 detection was built. NO2 with a volume fraction of 10−5 was taken as the sample gas through frequency scanning to obtain the frequency response curve of the system. The resonant frequency is 1730 Hz, and the cell constant is about 542.3 (Pa*cm)/W. The quality factor is 10.05. By linear fitting the calibration curve of the sensor, the fitting slope is 0.012 µV/ppb, and R2 is 0.998. Atmospheric NO2 detection was carried out for two consecutive weeks, whose findings are in good agreement with the data released by a Huainan environmental monitoring site. The experimental results show that the system can detect NO2 in the atmosphere with high sensitivity. Full article
Show Figures

Figure 1

16 pages, 4115 KB  
Review
Photoacoustic Resonators for Non-Invasive Blood Glucose Detection Through Photoacoustic Spectroscopy: A Systematic Review
by Md Rejvi Kaysir, Thasin Mohammad Zaman, Shazzad Rassel, Jishen Wang and Dayan Ban
Sensors 2024, 24(21), 6963; https://doi.org/10.3390/s24216963 - 30 Oct 2024
Cited by 10 | Viewed by 5491
Abstract
Diabetes mellitus is a prevalent disease with a rapidly increasing incidence projected worldwide, affecting both industrialized and developing regions. Effective diabetes management requires precise therapeutic strategies, primarily through self-monitoring of blood glucose levels to achieve tight glycemic control, thereby mitigating the risk of [...] Read more.
Diabetes mellitus is a prevalent disease with a rapidly increasing incidence projected worldwide, affecting both industrialized and developing regions. Effective diabetes management requires precise therapeutic strategies, primarily through self-monitoring of blood glucose levels to achieve tight glycemic control, thereby mitigating the risk of severe complications. In recent years, there have been significant advancements in non-invasive techniques for measuring blood glucose using photoacoustic spectroscopy (PAS), as it shows great promise for the detection of glucose using the infrared region (e.g., MIR and NIR) of light. A critical aspect of this method is the detection of the photoacoustic signal generated from blood glucose, which needs to be amplified through a photoacoustic resonator (PAR). In this work, an overview of various types of PARs used for non-invasive glucose sensing is reviewed, highlighting their operating principle, design requirements, limitations, and potential improvements needed to enhance the analysis of photoacoustic signals. The motivation behind this review is to identify and discuss main parameters crucial to the efficient design of PARs used in non-invasive glucose detection, which will be helpful for furthering the basic understanding of this technology and achieving the highly sensitive PAR required for non-invasive glucose monitoring. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

Back to TopTop