Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (2,089)

Search Parameters:
Keywords = passive ranging

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 1613 KiB  
Article
Evaluation of a Passive-Assist Exoskeleton Under Different Assistive Force Profiles in Agricultural Working Postures
by Naoki Saito, Takumi Kobayashi, Kohei Akimoto, Toshiyuki Satoh and Norihiko Saga
Actuators 2025, 14(8), 381; https://doi.org/10.3390/act14080381 (registering DOI) - 1 Aug 2025
Abstract
To enable the practical application of passive back-support exoskeletons employing pneumatic artificial muscles (PAMs) in tasks such as agricultural work, we evaluated their assistive effectiveness in a half-squatting posture with a staggered stance. In this context, assistive force profiles were adjusted according to [...] Read more.
To enable the practical application of passive back-support exoskeletons employing pneumatic artificial muscles (PAMs) in tasks such as agricultural work, we evaluated their assistive effectiveness in a half-squatting posture with a staggered stance. In this context, assistive force profiles were adjusted according to body posture to achieve more effective support. The targeted assistive force profile was designed to be continuously active from the standing to the half-squatting position, with minimal variation across this range. The assistive force profile was developed based on a PAM contractile force model and implemented using a cam mechanism. The effectiveness of assistance was assessed by measuring body flexion angles and erector spinae muscle activity during lifting and carrying tasks. The results showed that the assistive effect was greater on the side with the forward leg. Compared to the condition without exoskeleton assistance, the conventional pulley-based system reduced muscle activity by approximately 20% whereas the cam-based system achieved a reduction of approximately 30%. Full article
(This article belongs to the Special Issue Actuation and Sensing of Intelligent Soft Robots)
20 pages, 4215 KiB  
Article
Influence of Membrane Composition on the Passive Membrane Penetration of Industrially Relevant NSO-Heterocycles
by Zsófia Borbála Rózsa, Tamás Horváth, Béla Viskolcz and Milán Szőri
Int. J. Mol. Sci. 2025, 26(15), 7427; https://doi.org/10.3390/ijms26157427 (registering DOI) - 1 Aug 2025
Viewed by 70
Abstract
This study investigates how phospholipid headgroups influence passive membrane penetration and structural impact of four nitrogen-, sulfur-, and oxygen-containing heterocycles (NSO-HETs)—N-methyl-2-pyrrolidone (PIR), 1,4-dioxane (DIOX), oxane (OXA), and phenol (PHE). Using all-atom molecular dynamics simulations combined with Accelerated Weight Histogram free energy calculations, the [...] Read more.
This study investigates how phospholipid headgroups influence passive membrane penetration and structural impact of four nitrogen-, sulfur-, and oxygen-containing heterocycles (NSO-HETs)—N-methyl-2-pyrrolidone (PIR), 1,4-dioxane (DIOX), oxane (OXA), and phenol (PHE). Using all-atom molecular dynamics simulations combined with Accelerated Weight Histogram free energy calculations, the passive transport of NSO-HETs across DPPC, DPPE, DPPA, and DPPG bilayers was characterized. DPPG showed the highest membrane affinity, increasing permeability (logPmemb/bulk) by 27–64% compared to DPPE, associated with the lowest permeability and tightest lipid packing. Free energy barriers are also decreased in DPPG relative to DPPE; PIR’s central barrier dropped from 19.2 kJ/mol (DPPE) to 16.6 kJ/mol (DPPG), while DIOX’s barrier decreased from 7.2 to 5.2 kJ/mol. OXA exhibited the lowest central barriers (1.2–2.2 kJ/mol) and uniquely accumulated at higher concentrations in the bilayer center than in bulk water, with free energy ranging from −3.4 to −5.9 kJ/mol. PHE and OXA caused significant bilayer thinning (up to 11%) and reduced lipid tail order, especially in DPPE and DPPA. Concentration effects were most pronounced in DPPE, where high solute loading disrupted lipid order and altered free energy profiles. These results highlight the crucial role of headgroup identity in modulating NSO-HET membrane permeability and structural changes. Full article
(This article belongs to the Section Macromolecules)
Show Figures

Figure 1

22 pages, 1556 KiB  
Article
Long-Term Performance of Passive Volatile Organic Compounds (VOCs) Samplers for Indoor Air
by John H. Zimmerman, Brian Schumacher, Christopher C. Lutes, Brian Cosky and Heidi Hayes
Environments 2025, 12(8), 267; https://doi.org/10.3390/environments12080267 (registering DOI) - 31 Jul 2025
Viewed by 168
Abstract
The reliability of passive samplers in measuring volatile organic compounds (VOCs) in indoor air depends on whether the uptake rate is constant given the environmental conditions and sampler exposure duration. The first phase of this study evaluated the performance of charcoal-based, solvent-extracted passive [...] Read more.
The reliability of passive samplers in measuring volatile organic compounds (VOCs) in indoor air depends on whether the uptake rate is constant given the environmental conditions and sampler exposure duration. The first phase of this study evaluated the performance of charcoal-based, solvent-extracted passive samplers (e.g., Radiello® 130 passive samplers with white diffusive bodies) over exposure periods ranging from 1 week to 1 year in a test house with known vapor intrusion (VI). Chloroform %Bias values exceeded the ±30% acceptance criterion after 4 weeks exposure. Benzene, hexane, and trichloroethylene (TCE) concentrations were within the acceptance criterion for up to three months. Toluene and tetrachloroethylene (PCE), the two least volatile compounds, demonstrated uniform uptake rates over one year. In the second phase of this study, testing of the longer exposure times of 6 months and 1 year were evaluated with three additional passive samplers: Waterloo Membrane SamplerTM (WMSTM), SKC 575 with secondary diffusive cover, and Radiello® 130 passive samplers with yellow diffusive bodies. The SKC 575 and Radiello® 130 passive samplers produced acceptable results (%Bias ≤ 30%) over the 6-month exposure period, while the WMSTM sampler results favored petroleum hydrocarbon more than chlorinated solvent uptake. After the 1-year exposure period, the passive sampler performances were acceptable under specific conditions of this study. The results suggest that all three samplers can produce acceptable results over exposure time periods beyond 30 days and up to a year for some compounds. Full article
Show Figures

Figure 1

13 pages, 2066 KiB  
Article
Sport-Specific Shoulder Rotator Adaptations: Strength, Range of Motion, and Asymmetries in Female Volleyball and Handball Athletes
by Manca Lenart, Žiga Kozinc and Urška Čeklić
Symmetry 2025, 17(8), 1211; https://doi.org/10.3390/sym17081211 - 30 Jul 2025
Viewed by 160
Abstract
This study aimed to compare isometric strength, range of motion (RoM), and strength ratios of shoulder internal and external rotators between female volleyball and hand ball players Twenty-five volleyball players (age = 21.8 ± 4.8 years, height = 178.5 ± 7.1 cm, mass [...] Read more.
This study aimed to compare isometric strength, range of motion (RoM), and strength ratios of shoulder internal and external rotators between female volleyball and hand ball players Twenty-five volleyball players (age = 21.8 ± 4.8 years, height = 178.5 ± 7.1 cm, mass = 69.3 ± 7.7 kg) and twenty-four handball players (age = 19.5 ± 2.9 years, height = 169.7 ± 6.4 cm, mass = 67.6 ± 8.4 kg), all competing in the Slovenian 1st national league, participated. Maximal isometric strength and passive RoM of internal and external rotation were measured bilaterally using a handheld dynamometer and goniometer, respectively. A significant group × side interaction was observed for internal rotation RoM (F = 5.41; p = 0.024; η2 = 0.10), with volleyball players showing lower RoM on the dominant side (p = 0.001; d = 0.89), but this was not the case for handball players (p = 0.304). External rotation strength also showed a significant interaction (F = 9.34; p = 0.004; η2 = 0.17); volleyball players were stronger in the non-dominant arm (p = 0.033), while handball players were stronger in the dominant arm (p = 0.041). The external-to-internal rotation strength ratio was significantly lower on the dominant side in volleyball players compared to handball players (p = 0.047; d = 0.59). Findings suggest sport-specific adaptations and asymmetries in shoulder function, emphasizing the need for sport-specific and individually tailored injury prevention strategies. Volleyball players, in particular, may benefit from targeted strengthening of external rotators and flexibility training to address imbalances. Full article
(This article belongs to the Special Issue Application of Symmetry in Biomechanics)
Show Figures

Figure 1

16 pages, 1571 KiB  
Article
Effectiveness of Ultrasound-Guided Lavage for Rotator Cuff Calcific Tendinopathy: A Case Series Study from a Clinical and Radiological Perspective
by Lucrezia Moggio, Michele Mercurio, Nicola Marotta, Umile Giuseppe Longo, Giorgio Gasparini, Antonio Ammendolia and Alessandro de Sire
J. Clin. Med. 2025, 14(15), 5376; https://doi.org/10.3390/jcm14155376 - 30 Jul 2025
Viewed by 203
Abstract
Background/Objectives: Rotator cuff calcific tendinopathy (RCCT) is one of the most common causes of non-traumatic shoulder pain. To date, there is still no consensus regarding the most effective method for its treatment. Ultrasound-guided percutaneous aspiration is suggested during the reabsorption phase of [...] Read more.
Background/Objectives: Rotator cuff calcific tendinopathy (RCCT) is one of the most common causes of non-traumatic shoulder pain. To date, there is still no consensus regarding the most effective method for its treatment. Ultrasound-guided percutaneous aspiration is suggested during the reabsorption phase of calcific metaplasia. We aimed to evaluate the effectiveness of ultrasound-guided lavage for RCCT from a clinical and radiological perspective. Methods: We involved patients affected by RCCT of the supraspinatus tendon. The approach used for the calcification lavage was the one-needle technique, consisting in inserting a 16–18 G needle on a 20 mL syringe with 0.9% saline solution, in the calcific metaplasia, under ultrasound guidance, using an in-plane approach; the repetitive action of pressing and releasing the plunger was repeated until the contents of the syringe became milky, at which point the syringe was replaced with a new one, always containing saline solution. The physiotherapy treatment began 7 days after the procedure. We assessed the Numeric Rating Scale, the Gartner classification, the Disability of the Arm, Shoulder and Hand scale, the Constant–Murley shoulder score, and the passive range of motion of flexion and abduction. Results: We included 23 subjects. The analysis of the data at baseline and t1 showed a statistically significant improvement in all the functional variables (p < 0.05). This result was mainly evident for pain, with a p-value of 0.001. Conclusions: The findings of the present prospective case series study showed an improvement in the clinical and radiological outcomes after ultrasound-guided percutaneous aspiration for rotator cuff calcific tendinopathy. Full article
(This article belongs to the Special Issue Musculoskeletal Imaging and Intervention)
Show Figures

Figure 1

23 pages, 3453 KiB  
Article
Robust Peak Detection Techniques for Harmonic FMCW Radar Systems: Algorithmic Comparison and FPGA Feasibility Under Phase Noise
by Ahmed El-Awamry, Feng Zheng, Thomas Kaiser and Maher Khaliel
Signals 2025, 6(3), 36; https://doi.org/10.3390/signals6030036 - 30 Jul 2025
Viewed by 199
Abstract
Accurate peak detection in the frequency domain is fundamental to reliable range estimation in Frequency-Modulated Continuous-Wave (FMCW) radar systems, particularly in challenging conditions characterized by a low signal-to-noise ratio (SNR) and phase noise impairments. This paper presents a comprehensive comparative analysis of five [...] Read more.
Accurate peak detection in the frequency domain is fundamental to reliable range estimation in Frequency-Modulated Continuous-Wave (FMCW) radar systems, particularly in challenging conditions characterized by a low signal-to-noise ratio (SNR) and phase noise impairments. This paper presents a comprehensive comparative analysis of five peak detection algorithms: FFT thresholding, Cell-Averaging Constant False Alarm Rate (CA-CFAR), a simplified Matrix Pencil Method (MPM), SVD-based detection, and a novel Learned Thresholded Subspace Projection (LTSP) approach. The proposed LTSP method leverages singular value decomposition (SVD) to extract the dominant signal subspace, followed by signal reconstruction and spectral peak analysis, enabling robust detection in noisy and spectrally distorted environments. Each technique was analytically modeled and extensively evaluated through Monte Carlo simulations across a wide range of SNRs and oscillator phase noise levels, from 100 dBc/Hz to 70 dBc/Hz. Additionally, real-world validation was performed using a custom-built harmonic FMCW radar prototype operating in the 2.4–2.5 GHz transmission band and 4.8–5.0 GHz harmonic reception band. Results show that CA-CFAR offers the highest resilience to phase noise, while the proposed LTSP method delivers competitive detection performance with improved robustness over conventional FFT and MPM techniques. Furthermore, the hardware feasibility of each algorithm is assessed for implementation on a Xilinx FPGA platform, highlighting practical trade-offs between detection performance, computational complexity, and resource utilization. These findings provide valuable guidance for the design of real-time, embedded FMCW radar systems operating under adverse conditions. Full article
Show Figures

Graphical abstract

16 pages, 4613 KiB  
Article
Passive Layer Evolution of Anodized B206 Aluminum in Seawater for Tidal Energy Applications: An Electrochemical Approach
by Ibrahim M. Gadala, Shabnam Pournazari, Davood Nakhaie, Akram Alfantazi, Daan M. Maijer and Edouard Asselin
Metals 2025, 15(8), 846; https://doi.org/10.3390/met15080846 - 29 Jul 2025
Viewed by 237
Abstract
Aluminum–copper casting alloys are potential candidate materials for use in marine applications where high mechanical strength and superior fatigue resistance are desired. The corrosion and protection of aluminum alloy B206 in seawater through surface passivation continues to pose challenges, hampering its widespread use [...] Read more.
Aluminum–copper casting alloys are potential candidate materials for use in marine applications where high mechanical strength and superior fatigue resistance are desired. The corrosion and protection of aluminum alloy B206 in seawater through surface passivation continues to pose challenges, hampering its widespread use in marine structures. In this study, the electrochemical behavior of B206 is investigated in artificial seawater at temperatures and dissolved oxygen (DO) concentrations anticipated during service in marine environments. In particular, the influence of anodizing B206 in deaerated seawater on the subsequent corrosion behavior of the alloy is studied using potentiodynamic and potentiostatic polarization, electrochemical impedance spectroscopy (EIS), and Mott–Schottky analysis. The results showed that the effect of DO on the corrosion of B206 is more significant than the effect of temperature. In the absence of DO, results of potentiostatic polarization, EIS, and Mott–Schottky analysis at anodic potentials all indicated the development of a thicker, more protective passive layer in colder seawater. Moreover, passive layer thickness modeled using Power-Law was found to range between 3 and 9 nm, whilst decreasing in thickness with temperature. Donor densities of the n-type passive layer are on the order of 1021 cm−3 and increase with temperature. The findings presented in this study support the feasibility of implementing anodizing for B206 in marine service environments. Full article
Show Figures

Figure 1

16 pages, 14336 KiB  
Article
Three-Dimensional Binary Marker: A Novel Underwater Marker Applicable for Long-Term Deployment Scenarios
by Alaaeddine Chaarani, Patryk Cieslak, Joan Esteba, Ivan Eichhardt and Pere Ridao
J. Mar. Sci. Eng. 2025, 13(8), 1442; https://doi.org/10.3390/jmse13081442 - 28 Jul 2025
Viewed by 254
Abstract
Traditional 2D optical markers degrade quickly in underwater applications due to sediment accumulation and marine biofouling, becoming undetectable within weeks. This paper presents a Three-Dimensional Binary Marker, a novel passive fiducial marker designed for underwater Long-Term Deployment. The Three-Dimensional Binary Marker addresses the [...] Read more.
Traditional 2D optical markers degrade quickly in underwater applications due to sediment accumulation and marine biofouling, becoming undetectable within weeks. This paper presents a Three-Dimensional Binary Marker, a novel passive fiducial marker designed for underwater Long-Term Deployment. The Three-Dimensional Binary Marker addresses the 2D-markers limitation through a 3D design that enhances resilience and maintains contrast for computer vision detection over extended periods. The proposed solution has been validated through simulation, water tank testing, and long-term sea trials for 5 months. In each stage, the marker was compared based on detection per visible frame and the detection distance. In conclusion, the design demonstrated superior performance compared to standard 2D markers. The proposed Three-Dimensional Binary Marker provides compatibility with widely used fiducial markers, such as ArUco and AprilTag, allowing quick adaptation for users. In terms of fabrication, the Three-Dimensional Binary Marker uses additive manufacturing, offering a low-cost and scalable solution for underwater localization tasks. The proposed marker improved the deployment time of fiducial markers from a couple of days to sixty days and with a range up to seven meters, providing robustness and reliability. As the marker survivability and detection range depend on its size, it is still a valuable innovation for Autonomous Underwater Vehicles, as well as for inspection, maintenance, and monitoring tasks in marine robotics and offshore infrastructure applications. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

18 pages, 6211 KiB  
Article
An Optimization Method to Enhance the Accuracy of Noise Source Impedance Extraction Based on the Insertion Loss Method
by Rongxuan Zhang, Ziliang Zhang, Jun Zhan and Chunying Gong
Micromachines 2025, 16(8), 864; https://doi.org/10.3390/mi16080864 - 26 Jul 2025
Viewed by 287
Abstract
The optimal design of electromagnetic interference (EMI) filters relies on accurate characterization of noise source impedance. The conventional insertion loss method involves integrating two distinct passive two-port networks between the linear impedance stabilization network (LISN) and the equipment under test (EUT). The utilization [...] Read more.
The optimal design of electromagnetic interference (EMI) filters relies on accurate characterization of noise source impedance. The conventional insertion loss method involves integrating two distinct passive two-port networks between the linear impedance stabilization network (LISN) and the equipment under test (EUT). The utilization of the insertion loss to formulate a system of binary quadratic equations concerning the real and imaginary components of the impedance of the noise source enables the precise extraction of the magnitude and phase of the noise source impedance in theory. However, inherent inaccuracies in the insertion loss method during extraction can compromise impedance accuracy or even cause extraction failure. This work employs a series inductance method to overcome these limitations. Exact analytical expressions are derived for the magnitude and phase of the noise source impedance. Subsequently, the application scope of the series insertion loss method is analyzed, and the impact of insertion loss measurement error on noise source impedance extraction accuracy is quantified. Requirements for improving extraction accuracy are discussed, and method optimization strategies are proposed. The permissible range of insertion loss error ensuring a solution exists is deduced. Finally, simulation and experimental results validate the proposed approach in a buck converter. Full article
Show Figures

Figure 1

20 pages, 5070 KiB  
Article
Electrochemical Noise Analysis in Passivated Martensitic Precipitation-Hardening Stainless Steels in H2SO4 and NaCl Solutions
by Facundo Almeraya-Calderon, Miguel Villegas-Tovar, Erick Maldonado-Bandala, Demetrio Nieves-Mendoza, Ce Tochtli Méndez-Ramírez, Miguel Angel Baltazar-Zamora, Javier Olguín-Coca, Luis Daimir Lopez-Leon, Griselda Santiago-Hurtado, Verónica Almaguer-Cantu, Jesus Manuel Jaquez-Muñoz and Citlalli Gaona-Tiburcio
Metals 2025, 15(8), 837; https://doi.org/10.3390/met15080837 - 26 Jul 2025
Viewed by 289
Abstract
Precipitation-hardenable stainless steels (PHSS) are widely used in various applications in the aeronautical industry such in as landing gear supports, actuators, and fasteners, among others. This research aims to study the pitting corrosion behavior of passivated martensitic precipitation-hardening stainless steel, which underwent passivation [...] Read more.
Precipitation-hardenable stainless steels (PHSS) are widely used in various applications in the aeronautical industry such in as landing gear supports, actuators, and fasteners, among others. This research aims to study the pitting corrosion behavior of passivated martensitic precipitation-hardening stainless steel, which underwent passivation for 120 min at 25 °C and 50 °C in citric and nitric acid baths before being immersed in solutions containing 1 wt.% sulfuric acid (H2SO4) and 5 wt.% sodium chloride (NaCl). Electrochemical characterization was realized employing electrochemical noise (EN), while microstructural analysis employed scanning electron microscopy (SEM). The result indicates that EN reflects localized pitting corrosion mechanisms. Samples exposed to H2SO4 revealed activation–passivation behavior, whereas those immersed in NaCl exhibited pseudo-passivation, indicative of an unstable oxide film. Current densities in both solutions ranged from 10−3 to 10−5 mA/cm2, confirming susceptibility to localized pitting corrosion in all test conditions. The susceptibility to localized attack is associated with the generation of secondary oxides on the surface. Full article
(This article belongs to the Special Issue Recent Advances in High-Performance Steel)
Show Figures

Figure 1

18 pages, 1352 KiB  
Study Protocol
Effects of Hydrodilatation at Different Volumes on Adhesive Capsulitis in Phases 1 and 2: Clinical Trial Protocol HYCAFVOL
by Javier Muñoz-Paz, Ana Belén Jiménez-Jiménez, Francisco Espinosa-Rueda, Amin Wahab-Albañil, María Nieves Muñoz-Alcaraz, José Peña-Amaro and Fernando Jesús Mayordomo-Riera
Clin. Pract. 2025, 15(8), 141; https://doi.org/10.3390/clinpract15080141 - 26 Jul 2025
Viewed by 271
Abstract
Background: Adhesive capsulitis (AC) causes a global limitation of both active and passive range of motion (ROM) in the shoulder, with or without pain, and no specific radiographic findings. Its course is self-limiting and progresses through three or four stages. The diagnosis [...] Read more.
Background: Adhesive capsulitis (AC) causes a global limitation of both active and passive range of motion (ROM) in the shoulder, with or without pain, and no specific radiographic findings. Its course is self-limiting and progresses through three or four stages. The diagnosis is primarily clinical, since imaging tests are nonspecific. Treatment options include physical therapy (PT), intra-articular corticosteroid injections, suprascapular nerve block (SSNB), and hydrodilatation (HD). The latter is useful for expanding and reducing inflammation of the joint capsule through the insufflation of saline solution, anesthetics, and corticosteroids. Objectives: To compare whether patients with AC, stratified by phase 1 and 2, who receive high-volume HD as treatment achieve better outcomes in terms of shoulder pain and function compared to patients who receive low-volume HD. To compare whether there are differences in PT times and to determine mean axillary recess (AR) values. Methods: A randomized, parallel-block, triple-blind clinical trial will be conducted in 64 patients with AC in phases 1 and 2, aged 30 to 70 years, with limited active and passive ROM in two planes, and shoulder pain lasting more than 3 months. HD will be administered with volumes of 20 mL or 40 mL, followed by a conventional rehabilitation program. Outcomes will be reviewed at the 1st, 3rd, and 6th months of HD. Variables collected will include Shoulder Pain and Disability Index (SPADI), Visual Analog Scale (VAS), Range of motion (ROM), Lattinen index (LI), AR size, and time to completion of PT. Results: HD has been gaining clinical relevance in interventional rehabilitation as a treatment for AC, although its medium- and long-term efficacy remains a matter of debate. The variability in the volumes used for capsular expansion, with studies ranging from 18 mL to 47 mL, is compounded by the fact that most of these studies do not differentiate between AC stages. This could influence treatment effectiveness. Furthermore, diagnosis remains a challenge since valid and specific diagnostic parameters are lacking. Conclusions: Understanding the differences between HD techniques, considering the influence of certain factors such as the volume used or the stages of AC, as well as improving diagnosis and the coordination of scientific work. This could facilitate the development of protocols for the use of HD in AC. Full article
Show Figures

Figure 1

16 pages, 1042 KiB  
Review
A Review on Passivation Strategies for Germanium-Based Thermophotovoltaic Devices
by Pablo Martín and Ignacio Rey-Stolle
Materials 2025, 18(15), 3427; https://doi.org/10.3390/ma18153427 - 22 Jul 2025
Viewed by 303
Abstract
Interest in germanium electronic devices is experiencing a comeback thanks to their suitability for a wide range of new applications, like CMOS transistors, quantum technology or infrared photonics. Among these applications, Ge-based thermophotovoltaic converters could become the backbone of thermo-electrical batteries. However, these [...] Read more.
Interest in germanium electronic devices is experiencing a comeback thanks to their suitability for a wide range of new applications, like CMOS transistors, quantum technology or infrared photonics. Among these applications, Ge-based thermophotovoltaic converters could become the backbone of thermo-electrical batteries. However, these devices are still far from the efficiency threshold needed for industrial deployment, with surface recombination as the main limiting factor for the material. In this work, we discuss the main passivation techniques developed for germanium photovoltaic and thermophotovoltaic devices, summarizing their main advantages and disadvantages. The analysis reveals that surface recombination velocities as low as 2.7 cm/s and 1.3 cm/s have already been reported for p-type and n-type germanium, respectively, although improving surface recombination velocities below 100 cm/s would result in marginal efficiency gains. Therefore, the main challenge for the material is not reducing this parameter further but developing robust and reliable processes for integrating the current techniques into functional devices. Full article
Show Figures

Figure 1

49 pages, 15060 KiB  
Review
A Comprehensive Review of Thermal Management Challenges and Safety Considerations in Lithium-Ion Batteries for Electric Vehicles
by Ali Alawi, Ahmed Saeed, Mostafa H. Sharqawy and Mohammad Al Janaideh
Batteries 2025, 11(7), 275; https://doi.org/10.3390/batteries11070275 - 19 Jul 2025
Viewed by 1093
Abstract
The transition to electric vehicles (EVs) is accelerating due to global efforts to reduce greenhouse gas emissions and reliance on fossil fuels. Lithium-ion batteries (LIBs) are the predominant energy storage solution in EVs, offering high energy density, efficiency, and long lifespan. However, their [...] Read more.
The transition to electric vehicles (EVs) is accelerating due to global efforts to reduce greenhouse gas emissions and reliance on fossil fuels. Lithium-ion batteries (LIBs) are the predominant energy storage solution in EVs, offering high energy density, efficiency, and long lifespan. However, their adoption is overly involved with critical safety concerns, including thermal runaway and overheating. This review systematically focuses on the critical role of battery thermal management systems (BTMSs), such as active, passive, and hybrid cooling systems, in maintaining LIBs within their optimal operating temperature range, ensuring temperature homogeneity, safety, and efficiency. Additionally, the study explores the impact of integrating artificial intelligence (AI) and machine learning (ML) into BTMS on thermal performance prediction and energy-efficient cooling, focusing on optimizing the operating parameters of cooling systems. This review provides insights into enhancing LIB safety and performance for widespread EV adoption by addressing these challenges. Full article
Show Figures

Figure 1

20 pages, 7035 KiB  
Article
Microstructure Evolution Mechanism and Corrosion Resistance of FeCrNi(AlTi)x Medium Entropy Alloy Prepared by Laser Melting Deposition with Al and Ti Content Changes
by Kai Wang, Mingjie Liu, Chuan Liu, Xiaohui Li and Guanghui Shao
Coatings 2025, 15(7), 851; https://doi.org/10.3390/coatings15070851 - 19 Jul 2025
Viewed by 309
Abstract
In order to improve the microstructure and corrosion resistance of entropy alloy in the FeCrNi system, laser melting deposition technology was used as a preparation method to study the effects of different contents of Al and Ti on the microstructure and corrosion resistance [...] Read more.
In order to improve the microstructure and corrosion resistance of entropy alloy in the FeCrNi system, laser melting deposition technology was used as a preparation method to study the effects of different contents of Al and Ti on the microstructure and corrosion resistance of entropy alloy in FeCrNi(AlTi)x (x = 0.17, 0.2, and 0.24). The results show that the addition of Al and Ti elements can change the phase structure of the alloy from a single FCC phase structure to an FCC + BCC biphase structure. The BCC phase volume fraction of FeCrNi(AlTi)0.2 is the highest among the three alloys, reaching 37.5%. With the addition of Al and Ti content, the grain of the alloy will be refined to a certain extent. In addition, the dual-phase structure will also improve the corrosion resistance of the alloy. In 3.5 wt.% NaCl solution, the increase of Al and Ti content can effectively improve the protection of the passivation film on the surface of the entropy alloy in FeCrNi(AlTi)x, effectively inhibit the large-scale corrosion phenomenon on the alloy surface, and thus improve the corrosion resistance of the alloy. In a certain range, increasing the content of Al and Ti elements in the FeCrNi(AlTi)x system can improve the corrosion resistance of the alloy. Full article
Show Figures

Figure 1

41 pages, 2729 KiB  
Review
Memristor Emulator Circuits: Recent Advances in Design Methodologies, Healthcare Applications, and Future Prospects
by Amel Neifar, Imen Barraj, Hassen Mestiri and Mohamed Masmoudi
Micromachines 2025, 16(7), 818; https://doi.org/10.3390/mi16070818 - 17 Jul 2025
Viewed by 499
Abstract
Memristors, as the fourth fundamental circuit element, have attracted significant interest for their potential in analog signal processing, computing, and memory storage technologies. However, physical memristor implementations still face challenges in reproducibility, scalability, and integration with standard CMOS processes. Memristor emulator circuits, implemented [...] Read more.
Memristors, as the fourth fundamental circuit element, have attracted significant interest for their potential in analog signal processing, computing, and memory storage technologies. However, physical memristor implementations still face challenges in reproducibility, scalability, and integration with standard CMOS processes. Memristor emulator circuits, implemented using analog, digital, and mixed components, have emerged as practical alternatives, offering tunability, cost effectiveness, and compatibility with existing fabrication technologies for research and prototyping. This review paper provides a comprehensive analysis of recent advancements in memristor emulator design methodologies, including active and passive analog circuits, digital implementations, and hybrid approaches. A critical evaluation of these emulation techniques is conducted based on several performance metrics, including maximum operational frequency range, power consumption, and circuit topology. Additional parameters are also taken into account to ensure a comprehensive assessment. Furthermore, the paper examines promising healthcare applications of memristor and memristor emulators, focusing on their integration into biomedical systems. Finally, key challenges and promising directions for future research in memristor emulator development are outlined. Overall, the research presented highlights the promising future of memristor emulator technology in bridging the gap between theoretical memristor models and practical circuit implementations. Full article
(This article belongs to the Section E:Engineering and Technology)
Show Figures

Figure 1

Back to TopTop