Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (216)

Search Parameters:
Keywords = magnetoresistance sensor

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 2386 KB  
Article
Introduction of RKKY-pMTJ-Based Ultrafast Magnetic Sensor Architecture and Magnetic Multilayer Optimization
by Jaehun Cho and June-Seo Kim
Sensors 2025, 25(21), 6793; https://doi.org/10.3390/s25216793 - 6 Nov 2025
Viewed by 289
Abstract
A state-of-the-art tunnel magnetoresistance (TMR) sensor architecture, which is based on the perpendicularly magnetized magnetic tunnel junction (pMTJ), is introduced and engineered for ultrafast, high thermal stability, and linearity for magnetic field detection. Limitations in high-frequency environments, stemming from insufficient thermal stability and [...] Read more.
A state-of-the-art tunnel magnetoresistance (TMR) sensor architecture, which is based on the perpendicularly magnetized magnetic tunnel junction (pMTJ), is introduced and engineered for ultrafast, high thermal stability, and linearity for magnetic field detection. Limitations in high-frequency environments, stemming from insufficient thermal stability and slow recovery times in conventional TMR sensors, are overcome by this approach. The standard MRAM structure is modified, and the Ruderman–Kittel–Kasuya–Yosida (RKKY) interaction is employed to give a strong, internal restoring torque to the storage layer magnetization. Sensor linearity is also ensured by this RKKY mechanism, and rapid relaxation to the initial spin state is observed when an external field is removed. The structural and magnetic properties of the multilayer stack are experimentally demonstrated. Robust synthetic antiferromagnetic (SAF) coupling is confirmed by using polar MOKE spectroscopy with an optimal Ru insertion layer thickness (0.6 nm), which is essential for high thermal stability. Subsequently, an ultrafast response of this TMR sensor architecture is probed by micromagnetic simulations. The storage layer magnetization rapidly recovers to the SAF state within an ultrashort time of 5.78 to 5.99 ns. This sub-6 ns recovery time scale suggests potential operation into the hundreds of MHz range. Full article
(This article belongs to the Section State-of-the-Art Sensors Technologies)
Show Figures

Figure 1

22 pages, 4298 KB  
Article
Electronic Noise Measurement of a Magnetoresistive Sensor: A Comparative Study
by Cristina Davidaș, Elena Mirela Ștețco, Liviu Marin Viman, Mihai Sebastian Gabor, Ovidiu Aurel Pop and Traian Petrișor
Sensors 2025, 25(19), 6182; https://doi.org/10.3390/s25196182 - 6 Oct 2025
Viewed by 661
Abstract
The intrinsic noise of giant magnetoresistive (GMR) sensors is large at low frequencies, and their resolution is inevitably significantly limited. Investigation of GMR noise requires the use of measurement systems that have lower noise than the sample. In this context, the main purpose [...] Read more.
The intrinsic noise of giant magnetoresistive (GMR) sensors is large at low frequencies, and their resolution is inevitably significantly limited. Investigation of GMR noise requires the use of measurement systems that have lower noise than the sample. In this context, the main purpose of this study is to evaluate the effectiveness of two electronic noise measurement configurations of a single GMR sensing element. The first method connects the sample in a voltage divider configuration and the second method connects in a Wheatstone bridge configuration. Three amplification set-ups were investigated: a low-noise amplifier, an ultra-low-noise amplifier and an instrumentation amplifier. Using cross-correlation, the noise of the measurement system introduced by the amplifiers was reduced. Noise spectra were recorded at room temperature in the frequency range of 0.5 Hz to 10 kHz, under different sample bias voltages. The measurements were performed in zero applied magnetic field and in a field corresponding to the maximum sensitivity of the sensor. From the noise spectra, the detectivity of the sensor was determined to be in the 200–300 nT/√Hz range. Good agreement was observed between the results obtained using all three set-ups, suggesting the effectiveness of the noise measurement systems applied to the magnetoresistive sensor. Full article
(This article belongs to the Special Issue Advances and Applications of Magnetic Sensors: 2nd Edition)
Show Figures

Figure 1

20 pages, 3300 KB  
Article
Development of an Integrated Forestry Survey Device for Tree Height and DBH
by Ao Xu, Xianfang Zheng, Kejie Zhao, Shaobin Zhang, Linhao Sun and Luming Fang
Forests 2025, 16(10), 1529; https://doi.org/10.3390/f16101529 - 30 Sep 2025
Viewed by 339
Abstract
Tree diameter at breast height (DBH) and tree height are important quantitative attributes in forestry surveys. They serve as essential data for calculating forest stock, growth, and carbon sequestration, and are of significant research value for forest health assessments and other research outcomes. [...] Read more.
Tree diameter at breast height (DBH) and tree height are important quantitative attributes in forestry surveys. They serve as essential data for calculating forest stock, growth, and carbon sequestration, and are of significant research value for forest health assessments and other research outcomes. To improve the efficiency of forest resource inventories and to reduce labor costs, a forestry survey device integrating multiple sensors has been developed. Based on the principles of laser ranging and the tunnel magnetoresistance effect, this device integrates both the DBH and tree height measurements. Compared to traditional measurement methods, it boasts a compact size, low cost, and high measurement accuracy. Experimental applications have shown that the average root mean square error (RMSE) of tree height measurements ranges from 31 to 55 cm, while the DBH measurement accuracy reaches 98%, We acknowledge that, although this accuracy meets the requirements for general forestry surveys, it still falls short of the accuracy required for high-precision forest resource surveys (<20 cm), which points to a direction for future improvement. Full article
(This article belongs to the Special Issue Forest Resources Inventory, Monitoring, and Assessment)
Show Figures

Figure 1

22 pages, 5182 KB  
Article
A Novel TMR Cantilever-Based Bi-Directional Flow Sensor for Agricultural and Domestic Applications
by Anwar Ulla Khan and Ateyah Alzahrani
Sensors 2025, 25(18), 5915; https://doi.org/10.3390/s25185915 - 22 Sep 2025
Viewed by 2373
Abstract
This article introduces a novel, cost-effective, noninvasive sensing mechanism for measuring water flow rate. It employs two tunneling magnetoresistance (TMR) sensors (analog and bi-polar), a magnet, and a stainless-steel cantilever. The TMR sensors are installed outside the insulating water pipe. A magnet is [...] Read more.
This article introduces a novel, cost-effective, noninvasive sensing mechanism for measuring water flow rate. It employs two tunneling magnetoresistance (TMR) sensors (analog and bi-polar), a magnet, and a stainless-steel cantilever. The TMR sensors are installed outside the insulating water pipe. A magnet is fixed at the free end of the cantilever and integrated into the pipe system. The cantilever’s deflection corresponds to the flow rate, with an analog TMR sensor measuring the bending angle. This bending angle, in either direction of the cantilever’s deflection, is captured through the analog voltage from the TMR sensor. The output from the analog TMR sensor is an analog voltage that directly reflects the strength of the magnetic field. An ESP32 microcontroller records the voltage from the analog TMR sensor, converts it to flow rates, and utilizes the bi-polar TMR sensor to ascertain the flow direction. A prototype sensor was developed and tested in a laboratory-scale setup to validate the effectiveness of the sensing mechanism. This prototype demonstrated a worst-case accuracy of 1.0% across flow rates of 0 to 1.5 m3/h for both the forward and reverse flow directions. The response and recovery times of the sensor are approximately 470 ms and 592 ms for forward and 487 ms and 625 ms for reverse direction flow. Also, hysteresis errors of 1.84% and 2.06% have been calculated for both flow directions. Notably, the sensing element does not contain any rotating components or require electrical connections to the cantilever for measurement. These attributes potentially lead to lower maintenance requirements and a longer lifespan for the sensor. Full article
Show Figures

Figure 1

16 pages, 4245 KB  
Article
Van der Waals Magnetic Tunnel Junctions Based on Two-Dimensional 1T-VSe2 and Rotationally Aligned h-BN Monolayer
by Qiaoxuan Zhang, Cong Wang, Wenjie Wang, Rong Sun, Rongjie Zheng, Qingchang Ji, Hongwei Yan, Zhengbo Wang, Xin He, Hongyan Wang, Chang Yang, Jinchen Yu, Lingjiang Zhang, Ming Lei and Zhongchang Wang
Nanomaterials 2025, 15(16), 1246; https://doi.org/10.3390/nano15161246 - 14 Aug 2025
Viewed by 599
Abstract
Magnetic tunnel junctions (MTJs) are pivotal for spintronic applications such as magneto resistive memory and sensors. Two-dimensional van der Waals heterostructures offer a promising platform for miniaturizing MTJs while enabling the twist-angle engineering of their properties. Here, we investigate the impact of twisting [...] Read more.
Magnetic tunnel junctions (MTJs) are pivotal for spintronic applications such as magneto resistive memory and sensors. Two-dimensional van der Waals heterostructures offer a promising platform for miniaturizing MTJs while enabling the twist-angle engineering of their properties. Here, we investigate the impact of twisting the insulating barrier layer on the performance of a van der Waals MTJ with the structure graphene/1T-VSe2/h-BN/1T-VSe2/graphene, where 1T-VSe2 serves as the ferromagnetic electrodes and the monolayer h-BN acts as the tunnel barrier. Using first-principles calculations based on density functional theory (DFT) combined with the non-equilibrium Green’s function (NEGF) formalism, we systematically calculate the spin-dependent transport properties for 18 distinct rotational alignments of the h-BN layer (0° to 172.4°). Our results reveal that the tunneling magnetoresistance (TMR) ratio exhibits dramatic, rotation-dependent variations, ranging from 2328% to 24,608%. The maximum TMR occurs near 52.4°. An analysis shows that the twist angle modifies the d-orbital electronic states of interfacial V atoms in the 1T-VSe2 layers and alters the spin polarization at the Fermi level, thereby governing the spin-dependent transmission through the barrier. This demonstrates that rotational manipulation of the h-BN layer provides an effective means to engineer the TMR and performance of van der Waals MTJs. Full article
(This article belongs to the Section 2D and Carbon Nanomaterials)
Show Figures

Graphical abstract

15 pages, 24344 KB  
Article
The Influence of Dimensional Parameters on the Characteristics of Magnetic Flux Concentrators Used in Tunneling Magnetoresistance Devices
by Ran Bi, Huiquan Zhang, Shi Pan, Xinting Liu, Ruiying Chen, Shilin Wu and Jun Hu
Sensors 2025, 25(15), 4739; https://doi.org/10.3390/s25154739 - 31 Jul 2025
Viewed by 664
Abstract
Measuring weak magnetic fields proposes significant challenges to the sensing capabilities of magnetic field sensors. The magnetic field detection capacity of tunnel magnetoresistance (TMR) sensors is often insufficient for such applications, necessitating targeted optimization strategies to improve their performance in weak-field measurements. Utilizing [...] Read more.
Measuring weak magnetic fields proposes significant challenges to the sensing capabilities of magnetic field sensors. The magnetic field detection capacity of tunnel magnetoresistance (TMR) sensors is often insufficient for such applications, necessitating targeted optimization strategies to improve their performance in weak-field measurements. Utilizing magnetic flux concentrators (MFCs) offers an effective approach to enhance TMR sensitivity. In this study, the finite element method was employed to analyze the effects of different MFC geometric structures on the uniformity of the magnetic field in the air gap and the magnetic circuit gain (MCG). It was determined that the MCG of the MFC is not directly related to the absolute values of its parameters but rather to their ratios. Simulation analyses evaluated the impact of these parameter ratios on both the MCG and its spatial distribution uniformity, leading to the formulation of MFC design optimization principles. Building on these simulation-derived principles, several MFCs were fabricated using the 1J85 material, and an experimental platform was established to validate the simulation findings. The fabricated MFCs achieved an MCG of 7.325 times. Based on the previously developed TMR devices, a detection sensitivity of 2.46 nT/Hz @1Hz was obtained. By optimizing parameter configurations, this work provides theoretical guidance for further enhancing the performance of TMR sensors in magnetic field measurements. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

14 pages, 1682 KB  
Article
Recording of Cardiac Excitation Using a Novel Magnetocardiography System with Magnetoresistive Sensors Outside a Magnetic Shielded Room
by Leo Yaga, Miki Amemiya, Yu Natsume, Tomohiko Shibuya and Tetsuo Sasano
Sensors 2025, 25(15), 4642; https://doi.org/10.3390/s25154642 - 26 Jul 2025
Cited by 1 | Viewed by 1895
Abstract
Magnetocardiography (MCG) provides a non-invasive, contactless technique for evaluating the magnetic fields generated by cardiac electrical activity, offering unique spatial insights into cardiac electrophysiology. However, conventional MCG systems depend on superconducting quantum interference devices that require cryogenic cooling and magnetic shielded environments, posing [...] Read more.
Magnetocardiography (MCG) provides a non-invasive, contactless technique for evaluating the magnetic fields generated by cardiac electrical activity, offering unique spatial insights into cardiac electrophysiology. However, conventional MCG systems depend on superconducting quantum interference devices that require cryogenic cooling and magnetic shielded environments, posing considerable impediments to widespread clinical adoption. In this study, we present a novel MCG system utilizing a high-sensitivity, wide-dynamic-range magnetoresistive sensor array operating at room temperature. To mitigate environmental interference, identical sensors were deployed as reference channels, enabling adaptive noise cancellation (ANC) without the need for traditional magnetic shielding. MCG recordings were obtained from 40 healthy participants, with signals processed using ANC, R-peak-synchronized averaging, and Bayesian spatial signal separation. This approach enabled the reliable detection of key cardiac components, including P, QRS, and T waves, from the unshielded MCG recordings. Our findings underscore the feasibility of a cost-effective, portable MCG system suitable for clinical settings, presenting new opportunities for noninvasive cardiac diagnostics and monitoring. Full article
(This article belongs to the Special Issue Novel Optical Sensors for Biomedical Applications—2nd Edition)
Show Figures

Figure 1

24 pages, 8345 KB  
Article
Enhancing Reliability in Redundant Homogeneous Sensor Arrays with Self-X and Multidimensional Mapping
by Elena Gerken and Andreas König
Sensors 2025, 25(13), 3841; https://doi.org/10.3390/s25133841 - 20 Jun 2025
Cited by 2 | Viewed by 3290
Abstract
Mechanical defects and sensor failures can substantially undermine the reliability of low-cost sensors, especially in applications where measurement inaccuracies or malfunctions may lead to critical outcomes, including system control disruptions, emergency scenarios, or safety hazards. To overcome these challenges, this paper presents a [...] Read more.
Mechanical defects and sensor failures can substantially undermine the reliability of low-cost sensors, especially in applications where measurement inaccuracies or malfunctions may lead to critical outcomes, including system control disruptions, emergency scenarios, or safety hazards. To overcome these challenges, this paper presents a novel Self-X architecture with sensor redundancy, which incorporates dynamic calibration based on multidimensional mapping. By extracting reliable sensor readings from imperfect or defective sensors, the system utilizes Self-X principles to dynamically adapt and optimize performance. The approach is initially validated on synthetic data from tunnel magnetoresistance (TMR) sensors to facilitate method analysis and comparison. Additionally, a physical measurement setup capable of controlled fault injection is described, highlighting practical validation scenarios and ensuring the realism of synthesized fault conditions. The study highlights a wide range of potential TMR sensor failures that compromise long-term system reliability and demonstrates how multidimensional mapping effectively mitigates both static and dynamic errors, including offset, amplitude imbalance, phase shift, mechanical misalignments, and other issues. Initially, four individual TMR sensors exhibited mean absolute error (MAE) of 4.709°, 5.632°, 2.956°, and 1.749°, respectively. To rigorously evaluate various dimensionality reduction (DR) methods, benchmark criteria were introduced, offering insights into the relative improvements in sensor array accuracy. On average, MAE was reduced by more than 80% across sensor combinations. A clear quantitative trend was observed: for instance, the MAE decreases from 4.7°–5.6° for single sensors to 0.111° when the factor analysis method was applied to four sensors. This demonstrates the concrete benefit of sensor redundancy and DR algorithms for creating robust, fault-tolerant measurement systems. Full article
Show Figures

Figure 1

22 pages, 9995 KB  
Article
Skin-Inspired Magnetoresistive Tactile Sensor for Force Characterization in Distributed Areas
by Francisco Mêda, Fabian Näf, Tiago P. Fernandes, Alexandre Bernardino, Lorenzo Jamone, Gonçalo Tavares and Susana Cardoso
Sensors 2025, 25(12), 3724; https://doi.org/10.3390/s25123724 - 13 Jun 2025
Cited by 1 | Viewed by 1524
Abstract
Touch is a crucial sense for advanced organisms, particularly humans, as it provides essential information about the shape, size, and texture of contacting objects. In robotics and automation, the integration of tactile sensors has become increasingly relevant, enabling devices to properly interact with [...] Read more.
Touch is a crucial sense for advanced organisms, particularly humans, as it provides essential information about the shape, size, and texture of contacting objects. In robotics and automation, the integration of tactile sensors has become increasingly relevant, enabling devices to properly interact with their environment. This study aimed to develop a biomimetic, skin-inspired tactile sensor device capable of sensing applied force, characterizing it in three dimensions, and determining the point of application. The device was designed as a 4 × 4 matrix of tunneling magnetoresistive sensors, which provide a higher sensitivity in comparison to the ones based on the Hall effect, the current standard in tactile sensors. These detect magnetic field changes along a single axis, wire-bonded to a PCB and encapsulated in epoxy. This sensing array detects the magnetic field from an overlayed magnetorheological elastomer composed of Ecoflex and 5 µm neodymium–iron–boron ferromagnetic particles. Structural integrity tests showed that the device could withstand forces above 100 N, with an epoxy coverage of 0.12 mL per sensor chip. A 3D movement stage equipped with an indenting tip and force sensor was used to collect device data, which was then used to train neural network models to predict the contact location and 3D magnitude of the applied force. The magnitude-sensing model was trained on 31,260 data points, being able to accurately characterize force with a mean absolute error ranging between 0.07 and 0.17 N. The spatial sensitivity model was trained on 171,008 points and achieved a mean absolute error of 0.26 mm when predicting the location of applied force within a sensitive area of 25.5 mm × 25.5 mm using sensors spaced 4.5 mm apart. For points outside the testing range, the mean absolute error was 0.63 mm. Full article
(This article belongs to the Special Issue Smart Magnetic Sensors and Application)
Show Figures

Figure 1

13 pages, 3697 KB  
Article
Classification of Artificial Gear Damage by Angle Measurement Utilizing the Gear Wheel as a Material Measure
by Yanik Koch, Florian Michael Becker-Dombrowsky and Eckhard Kirchner
Appl. Sci. 2025, 15(12), 6446; https://doi.org/10.3390/app15126446 - 8 Jun 2025
Viewed by 666
Abstract
Gear condition monitoring is predominantly executed through the utilization of acceleration sensors positioned on the housing. However, recent advancements have identified measuring the instantaneous angular speed as a compelling alternative as it shortens the transmission path and therefore provides high-quality rotational angle information [...] Read more.
Gear condition monitoring is predominantly executed through the utilization of acceleration sensors positioned on the housing. However, recent advancements have identified measuring the instantaneous angular speed as a compelling alternative as it shortens the transmission path and therefore provides high-quality rotational angle information that can be used to increase damage prediction accuracy, particularly under transient operating conditions. Additionally, there are a variety of methodologies for integrating sensors into gears, which underscores the necessity for high-quality condition data. However, it should be noted that a significant amount of effort is required to successfully integrate these sensors into the rotating system. This publication uses a gear wheel sensor that employs the gear itself as a material measure to acquire rotational angle data and to deduce the damage condition. A magnetoresistive sensor is integrated into the gearbox housing radially facing a ferromagnetic gear and measures the rotational angle by the gear teeth. Various artificial tooth flank damages are applied to the pinion. The rotational angle is measured with the gear sensor, and the damage state is classified with a random forest classifier using established evaluations in the time and frequency domains. The tests are conducted under stationary operating conditions at an array of speed and torque levels. Additionally, they are performed under transient operating conditions, employing speed ramps at constant torque. The results of the classification are evaluated by means of classification accuracy and confusion matrices and compared with those obtained via a classic encoder at the pinion shaft and an acceleration sensor at the gearbox housing. Full article
(This article belongs to the Special Issue Novel Approaches for Fault Diagnostics of Machine Elements)
Show Figures

Figure 1

18 pages, 5532 KB  
Article
Investigation of a Magnetic Sensor Based on the Magnetic Hysteresis Loop and Anisotropic Magnetoresistance of CoFe Thin Films Epitaxial Grown on Flexible Mica and Rigid MgO Substrates with Strain Effect
by Jen-Chieh Cheng, Min-Chang You, Aswin kumar Anbalagan, Guang-Yang Su, Kai-Wei Chuang, Chao-Yao Yang and Chih-Hao Lee
Micromachines 2025, 16(4), 412; https://doi.org/10.3390/mi16040412 - 30 Mar 2025
Cited by 3 | Viewed by 805
Abstract
The anisotropic magnetoresistance (AMR) effect is widely used in microscale and nanoscale magnetic sensors. In this study, we investigate the correlation between AMR and the crystal structure, epitaxial relationship, and magnetic properties of Co50Fe50 thin films deposited on rigid MgO [...] Read more.
The anisotropic magnetoresistance (AMR) effect is widely used in microscale and nanoscale magnetic sensors. In this study, we investigate the correlation between AMR and the crystal structure, epitaxial relationship, and magnetic properties of Co50Fe50 thin films deposited on rigid MgO and flexible mica substrates. The AMR ratio is approximately 1.6% for CoFe films on mica, lower than the 2.5% observed in epitaxially grown films on MgO substrates. The difference is likely due to the well-defined easy axis in the single domain epitaxial thin films on MgO, which enhances the AMR ratio. Microscopic strain induced by lattice mismatch and bending on flexible substrates were determined using grazing incidence X-ray diffraction and extended X-ray absorption fine structure techniques. These results showed that neither microscopic nor macroscopic strain (below 0.5%) affects the AMR ratio on mica, suggesting its suitability for magnetic sensors in flexible and wearable devices. Additionally, investigating M-H loops under various growth temperatures, lattice mismatch conditions, and bending strains could further benefit the fabrication and integration of the micro-scale magnetic sensors in the microelectronic industry. Full article
(This article belongs to the Special Issue Feature Papers of Micromachines in 'Materials and Processing' 2024)
Show Figures

Figure 1

18 pages, 8023 KB  
Article
Two Degrees of Freedom Synchronous Motion Modulation Technique Using MEMS Voltage-Controlled Oscillator-Based Phase-Locked Loop for Magnetoresistive Sensing
by Zhenyu Shi, Zhenxiang Qi, Haoqi Lyu, Qifeng Jiao, Chen Chen and Xudong Zou
Sensors 2025, 25(6), 1835; https://doi.org/10.3390/s25061835 - 15 Mar 2025
Viewed by 2441
Abstract
This study presents a novel dual phase-locked loop two-dimensional synchronized motion modulation (TDSMM-DPLL) system designed to enhance the low-frequency detection capability of magnetoresistive (MR) sensors by effectively mitigating 1/f noise. The TDSMM-DPLL system integrates a comb-driven resonator and a piezoelectric cantilever beam resonator, [...] Read more.
This study presents a novel dual phase-locked loop two-dimensional synchronized motion modulation (TDSMM-DPLL) system designed to enhance the low-frequency detection capability of magnetoresistive (MR) sensors by effectively mitigating 1/f noise. The TDSMM-DPLL system integrates a comb-driven resonator and a piezoelectric cantilever beam resonator, achieving synchronized magnetic field modulation through a DPLL circuit that adjusts the resonant frequency of the comb-driven resonator to twice that of the cantilever beam resonator. Theoretical analysis and finite element simulations demonstrate a modulation efficiency of 38.98%, which is significantly higher than that of traditional one-dimensional modulation methods. Experimental validation confirms the system’s effectiveness, showing a 3.13-fold reduction in frequency Allan variance, decreasing from 217.32 ppb to 69.46 ppb, indicating substantial noise suppression. These results highlight the TDSMM-DPLL system’s potential to improve the performance of MR sensors in low-frequency applications, making it a promising solution for high-precision magnetic field detection. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

17 pages, 4437 KB  
Article
A Positioning System Design Based on Tunnel Magnetoresistance Sensors for Rapid Zoom Optical Lens
by Junqiang Gong, Dameng Liu and Jianbin Luo
Sensors 2025, 25(6), 1820; https://doi.org/10.3390/s25061820 - 14 Mar 2025
Cited by 1 | Viewed by 1306
Abstract
In response to the accurate positioning issue for high-speed moving lens groups in rapid zoom optical lenses with voice coil motors (VCMs), we demonstrate a positioning system design based on tunnel magnetoresistance sensors. The equivalent magnetic charge method and finite element method (FEM) [...] Read more.
In response to the accurate positioning issue for high-speed moving lens groups in rapid zoom optical lenses with voice coil motors (VCMs), we demonstrate a positioning system design based on tunnel magnetoresistance sensors. The equivalent magnetic charge method and finite element method (FEM) simulations were utilized to compute the magnetic field distribution of the magnetic grating encoder. Based on analytical computation, the optimal air gap δS between the sensor and magnetic grating is determined to be δS = 0.15 mm, which balances magnetic flux density amplitude and total harmonic distortion. In addition, a simplified fitting model is proposed to reduce computational complexity. We quantify the magnetic interference of VCM through three-dimensional flux leakage mapping by FEM analysis, deriving an optimal sensor position OS, with a 24 mm y-offset and 20 mm z-offset relative to the VCM’s origin OV. The position error caused by interference remains below 5 μm with maximum deviations at trajectory endpoints of the moving group. The original signal output is processed and corrected, and eventually, the measured displacement exhibits a linear relationship with actual displacement. Our study provides a comprehensive framework for the design and optimization of magnetic positioning systems in optical applications with electromagnetic motors. Full article
Show Figures

Figure 1

16 pages, 1923 KB  
Article
A High-Sensitivity, Low-Noise, and Low-Hysteresis Tunneling Magnetoresistance Sensor Based on Structural Optimization of Magnetic Tunnel Junctions
by Ran Bi, Ruiying Chen, Shilin Wu, Haoyu Ma, Huiquan Zhang, Xinting Liu, Jinliang He and Jun Hu
Sensors 2025, 25(6), 1730; https://doi.org/10.3390/s25061730 - 11 Mar 2025
Cited by 8 | Viewed by 2087
Abstract
Accurate measurement of magnetic fields holds immense significance across various disciplines, such as IC circuit measurement, geological exploration, and aerospace. The sensitivity and noise parameters of magnetic field sensors play a vital role in detecting minute fluctuations in magnetic fields. However, the current [...] Read more.
Accurate measurement of magnetic fields holds immense significance across various disciplines, such as IC circuit measurement, geological exploration, and aerospace. The sensitivity and noise parameters of magnetic field sensors play a vital role in detecting minute fluctuations in magnetic fields. However, the current detection capability of tunneling magnetoresistance (TMR) is insufficient to meet the requirements for weak magnetic field measurement. This study investigates the impact of structural and fabrication parameters on the performance of TMR sensors. We fabricated series-connected TMR sensors with varying long-axis lengths of the elliptical cross-section and adjusted their performance by modifying annealing magnetic fields and magnetic field bias along the easy axis. The results demonstrate that TMR sensitivity decreases with increasing long-axis length, increases initially and then decreases with an annealing magnetic field, and decreases with a higher bias magnetic field along the easy axis. The voltage noise level of TMR sensors decreases as the long-axis length increases. Notably, the detection capability of TMR sensors exhibits a non-monotonic dependence on long-axis length. Moreover, we optimized the hysteresis of TMR sensors by applying a magnetic field bias along the easy axis. When the bias along the easy axis reached 16 Oe or −40 Oe, the hysteresis level was reduced to below 0.5 Oe. After encapsulating the TMR devices into a full Wheatstone bridge structure, we achieved a detection capability of 17 nT/Hz@1Hz. This study highlights that the detection capability of TMR devices is jointly influenced by fabrication parameters. By optimizing parameter configuration, this work provides theoretical guidance for further enhancing the performance of TMR devices in magnetic field measurements. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

17 pages, 6962 KB  
Article
Magnetic Field Meter Based on CMR-B-Scalar Sensor for Measurement of Microsecond Duration Magnetic Field Pulses
by Pavel Piatrou, Voitech Stankevic, Nerija Zurauskiene, Skirmantas Kersulis, Mindaugas Viliunas, Algirdas Baskys, Martynas Sapurov, Vytautas Bleizgys, Darius Antonovic, Valentina Plausinaitiene, Martynas Skapas, Vilius Vertelis and Borisas Levitas
Sensors 2025, 25(6), 1640; https://doi.org/10.3390/s25061640 - 7 Mar 2025
Viewed by 1064
Abstract
This study presents a system for precisely measuring pulsed magnetic fields with high amplitude and microsecond duration with minimal interference. The system comprises a probe with an advanced magnetic field sensor and a measurement unit for signal conversion, analysis, and digitization. The sensor [...] Read more.
This study presents a system for precisely measuring pulsed magnetic fields with high amplitude and microsecond duration with minimal interference. The system comprises a probe with an advanced magnetic field sensor and a measurement unit for signal conversion, analysis, and digitization. The sensor uses a thin nanostructured manganite La-Sr-Mn-O film exhibiting colossal magnetoresistance, which enables precise magnetic field measurement independent of its orientation. Films with different compositions were optimized and tested in pulsed magnetic fields. The measurement unit includes a pulsed voltage generator, an ADC, a microcontroller, and an amplifier unit. Two versions of the measurement unit were developed: one with a separate amplifier unit configured for the sensor positioned more than 1 m away from the measurement unit, and the other with an integrated amplifier for the sensor positioned at a distance of less than 0.5 m. A bipolar pulsed voltage supplying the sensor minimized the parasitic effects of the electromotive force induced in the probe circuit. The data were transmitted via a fiber optic cable to a PC equipped with a special software for processing and recording. Tests with 20–30 μs pulses up to 15 T confirmed the effectiveness of the system for measuring high pulsed magnetic fields. Full article
(This article belongs to the Special Issue Magnetic Field Sensing and Measurement Techniques)
Show Figures

Figure 1

Back to TopTop