Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (88)

Search Parameters:
Keywords = magnetic recording technology

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 2117 KB  
Perspective
Noninvasive Neuromodulation and Neuroimaging to Enhance Glymphatic Function for Neurodegenerative and Autoimmune Disorders in Next-Generation Personalized Treatments and Precision Neuropsychiatry: A Perspective Proposal
by Castañeyra-Perdomo Agustín, José L. González-Mora, Sophocles Goulis, Risto J. Ilmoniemi, Pantelis Lioumis, Nikos Makris and Stefano Pallanti
Appl. Sci. 2026, 16(13), 6593; https://doi.org/10.3390/app16136593 - 2 Jul 2026
Viewed by 122
Abstract
Transcranial magnetic stimulation-electroencephalography (TMS–EEG) biomarkers have recently become available as a means to obtain new understanding of the causal chains of neuronal signaling in the brain. This is a key piece in the puzzle of how the brain is organized and how it [...] Read more.
Transcranial magnetic stimulation-electroencephalography (TMS–EEG) biomarkers have recently become available as a means to obtain new understanding of the causal chains of neuronal signaling in the brain. This is a key piece in the puzzle of how the brain is organized and how it works. Using dMRI tractography, we can map the circuit beneath a chosen cortical target; TMS can then stimulate it, and EEG records responses that reflect—and may even be caused by—activity in that structural circuit. The chain of events after stimulus delivery can be observed and quantified using current neuroimaging and TMS–EEG technology, a matter of tremendous relevance on how to approach novel therapeutic approaches in clinical conditions. Herein, we elaborate upon a perspective of how groundbreaking multi-locus TMS (mTMS) technology associated with EEG and multimodal neuroimaging can be applied to modulate the flow dynamics of the glymphatic system (GS). The enhancement of the GS waste clearance functionality has been shown to improve significantly symptom severity in neurodegenerative disorders such as Alzheimer’s (AD) and Parkinson’s disease (PD) or long COVID. In this perspective paper, we consider that next-generation therapeutics using versatile technologies such as noninvasive neuromodulation and neuroimaging will provide important benefits in public health and in how society can address the management of these difficult-to-deal-with ailments more effectively. Full article
(This article belongs to the Special Issue MR-Based Neuroimaging, 2nd Edition)
Show Figures

Figure 1

28 pages, 22158 KB  
Review
Brain–Computer Interface (BCI) and Neuroergonomics Applications in Transportation Systems: An Overview of Current Trends and Future Perspectives
by Marco Guerrieri
Appl. Sci. 2026, 16(12), 5737; https://doi.org/10.3390/app16125737 - 6 Jun 2026
Viewed by 603
Abstract
A brain–computer interface (BCI) is a complex system that allows humans to interact with physical devices by analysing and interpreting brain signals obtained from neuroimaging modalities (electroencephalography, electrocorticography, magnetoencephalography, intracortical neuron recording, functional magnetic resonance imaging, etc.). BCI applications in robotics and medicine [...] Read more.
A brain–computer interface (BCI) is a complex system that allows humans to interact with physical devices by analysing and interpreting brain signals obtained from neuroimaging modalities (electroencephalography, electrocorticography, magnetoencephalography, intracortical neuron recording, functional magnetic resonance imaging, etc.). BCI applications in robotics and medicine have demonstrated invaluable benefits. The rise of BCI technology and neuroergonomics techniques could also provide promising solutions in transportation systems, particularly in smart roads, vehicles, and traffic regulation systems. This narrative literature review examines how, in the age of smart transportation systems and self-driving vehicles, different far-future applications of BCI systems could be integrated to enhance the safety and capacity of transportation systems. Full article
(This article belongs to the Special Issue Advances in Virtual Reality and Vision for Driving Safety)
Show Figures

Figure 1

16 pages, 16417 KB  
Article
A Hierarchically Structured Composite Integrating a Biomass-Derived Magnetic Carbon Framework with Various Magnetic Phases, Exhibiting Outstanding Electromagnetic Wave Absorption Performance
by Yutao Zhang, Jiawei Bi, Tiancheng Yuan, Shenpeng Xia and Minzhen Bao
Molecules 2026, 31(10), 1775; https://doi.org/10.3390/molecules31101775 - 21 May 2026
Viewed by 570
Abstract
A lightweight and high-efficiency microwave-absorbing material was developed via an in situ solvothermal pyrolysis strategy by anchoring sphere-like Fe3O4 nanostructures onto bamboo-derived porous carbon (BPC). The resulting composites preserve the intrinsic anisotropic honeycomb architecture of bamboo while introducing uniformly distributed [...] Read more.
A lightweight and high-efficiency microwave-absorbing material was developed via an in situ solvothermal pyrolysis strategy by anchoring sphere-like Fe3O4 nanostructures onto bamboo-derived porous carbon (BPC). The resulting composites preserve the intrinsic anisotropic honeycomb architecture of bamboo while introducing uniformly distributed magnetic nanoparticles, enabling synergistic dielectric–magnetic loss. Electromagnetic parameters, alongside impedance matching, were successfully modulated through the optimization of precursor concentrations. Of the evaluated materials, BPC-0.9 stood out for its intense attenuation, recording an RLmin of −45.17 dB at a 1.8 mm thickness. Furthermore, a significant effective absorption bandwidth of 6.65 GHz was attained by the BPC-0.6 sample at only 2.2 mm. Several factors contribute to the boosted efficiency, starting with conductive and interfacial polarization losses paired with multiple scattering events. Furthermore, magnetic loss components, encompassing eddy current effects as well as natural and exchange resonances, play a pivotal role in optimizing the material’s response. Furthermore, radar cross-section (RCS) modeling reveals a substantial reduction of 19.9 dB·m2, verifying the material’s viability for real-world stealth technologies. Our findings offer a straightforward methodology for fabricating magnetic carbon structures from biomass with adjustable dielectric responses, underscoring their potential in high-performance energy conversion and low-density microwave absorption. Full article
(This article belongs to the Special Issue Emerging Multifunctional Materials for Next-Generation Energy Systems)
Show Figures

Graphical abstract

18 pages, 1693 KB  
Article
Neuromagnetism “On the Cheap”: Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans
by Lyam M. Bailey, Clara Knox and Timothy Bardouille
Sensors 2026, 26(10), 3131; https://doi.org/10.3390/s26103131 - 15 May 2026
Viewed by 379
Abstract
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically shielded rooms to reduce external electromagnetic noise and typically comprise sensor arrays covering the entire head. Such systems [...] Read more.
Background: Optically pumped magnetometers (OPMs) have emerged as a promising technology for neuromagnetic recording in humans. Current state-of-the-art OPM systems are housed in large magnetically shielded rooms to reduce external electromagnetic noise and typically comprise sensor arrays covering the entire head. Such systems are extremely costly to purchase and install, and take up large amounts of physical space, which limits the accessibility of this technology to research groups with limited funding. Here we sought to evaluate the utility of a more accessible “starter” OPM system comprising a small cylindrical mu-metal shield and partial sensor coverage. Methods: Twelve participants underwent right-sided median nerve stimulation (MNS) intended to elicit ubiquitous sensorimotor responses: somatosensory-evoked fields (SEFs, comprising N20m, P35m and P60m components) and event-related (de)synchronization (ERD/ERS) of oscillatory neuronal rhythms in the mu and beta frequency ranges. Results: Following MNS, we observed robust N20m and P60m peaks, as well as the expected mu ERD and beta ERS effects. Moreover, these responses could be localized to expected cortical generators. However, we observed markedly lower SNR than that seen in state-of-the-art systems. We make recommendations for further improvements to this system and others like it. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

23 pages, 1107 KB  
Systematic Review
Technological Pathways for Rare Earth Elements Recovery from WEEE: A Systematic Mapping Review
by Luca Taglieri, Pietro Romano, Francesco Vegliò, Alberto Gallifuoco and Luciano Fratocchi
Recycling 2026, 11(4), 65; https://doi.org/10.3390/recycling11040065 - 1 Apr 2026
Viewed by 1568
Abstract
Rare earth elements (REEs) are essential to many low-carbon and digital technologies, yet the primary supply is geographically concentrated; waste electrical and electronic equipment (WEEE) could act as an “urban mine”, but recovery pathways remain fragmented. We synthesize the evidence through a structured [...] Read more.
Rare earth elements (REEs) are essential to many low-carbon and digital technologies, yet the primary supply is geographically concentrated; waste electrical and electronic equipment (WEEE) could act as an “urban mine”, but recovery pathways remain fragmented. We synthesize the evidence through a structured literature review of Scopus and Web of Science indexed studies focusing on WEEE-derived feedstocks for REE recovery: 148 records were screened and 51 papers met the inclusion criteria. Reporting of the search and study selection process follows PRISMA 2020. We coded each study by WEEE source/fraction, core technology family, and process configuration, target REEs, performance reporting, environmental proxies, and maturity, and discussed gaps against circularity goals. Results show an intense concentration on a few feedstocks, permanent magnets (22 studies), fluorescent lamps (16), and batteries (6), with only limited attention to multi-source streams. Hydrometallurgical routes dominate, while biometallurgical options are less explored. Recovery is more frequently reported than selectivity and environmental indicators, and most solutions remain at proof-of-concept maturity. Due to the heterogeneity of feedstocks, process configurations, and reported metrics, the findings were synthesized qualitatively (no meta-analysis). This review highlights priorities for future work: multi-source and heavy rare earth elements focused feedstocks, more selective and intensified flowsheets, harmonized performance reporting, and scale-up supported by life-cycle and cost assessments. Full article
Show Figures

Graphical abstract

16 pages, 1577 KB  
Article
Signal Processing Techniques for Enhancing an Areal Density in Two-Reader/Three-Track Detection of Staggered Bit-Patterned Magnetic Recording Systems
by Natthakan Rueangnetr, Satra Tor. Wattanaphol, Kittipon Kankhunthod, Simon J. Greaves and Chanon Warisarn
Appl. Syst. Innov. 2026, 9(3), 66; https://doi.org/10.3390/asi9030066 - 23 Mar 2026
Viewed by 771
Abstract
As the demand for digital storage capacity continues to grow, bit-patterned magnetic recording (BPMR) has emerged as a promising technology to overcome the superparamagnetic limit of conventional recording methods. Nevertheless, the extremely close spacing of magnetic islands in BPMR can result in significant [...] Read more.
As the demand for digital storage capacity continues to grow, bit-patterned magnetic recording (BPMR) has emerged as a promising technology to overcome the superparamagnetic limit of conventional recording methods. Nevertheless, the extremely close spacing of magnetic islands in BPMR can result in significant signal corruption, particularly due to inter-track interference. This paper presents robust signal-processing schemes for a two-reader, three-track detection system in a staggered BPMR configuration to address these challenges. The first proposed method employs a sum-soft-information technique, which combines log-likelihood ratios from two detectors to maximize mutual information. This approach significantly improves the reliability of middle-track detection. We also propose the inter-track interference subtraction technique, in which the highly reliable data recovered from the middle track are used to reconstruct the interference signal, which is then subtracted from the upper and lower tracks using an optimized weighting factor. Simulation results at an areal density of 3.0 Tb/in2 demonstrate that an optimized weighting factor of 1.78 effectively cancels interference. Moreover, the results indicate that our proposed scheme achieves a bit-error rate (BER) comparable to that of the three-reader, one-track detection BPMR systems. Furthermore, our method also demonstrates a lower BER for both adjacent tracks when compared to the conventional single-reader, two-track reading system, even in the presence of 10% media noise. Full article
Show Figures

Figure 1

24 pages, 1003 KB  
Review
Diagnostic Potential of Metabolomic and Proteomic Biomarkers in Cardiology—A Narrative Review
by Lazzat Zhussupbekova, Dinara Nurkina, Gyulnar Zhussupova, Aliya Smagulova, Venera Rakhmetova, Elmira Akhmedyarova, Aisha Darybayeva, Klara Kurmangaliyeva and Ilya Kukes
Biomedicines 2026, 14(2), 257; https://doi.org/10.3390/biomedicines14020257 - 23 Jan 2026
Cited by 2 | Viewed by 2309
Abstract
Cardiovascular disease is a major cause of death worldwide and a global socio-economic problem. To date, there are numerous studies focused on finding new biomarkers of cardiovascular diseases. High-technological methods such as mass spectrometry (MS), high-performance liquid chromatography (HPLC), and nuclear magnetic resonance [...] Read more.
Cardiovascular disease is a major cause of death worldwide and a global socio-economic problem. To date, there are numerous studies focused on finding new biomarkers of cardiovascular diseases. High-technological methods such as mass spectrometry (MS), high-performance liquid chromatography (HPLC), and nuclear magnetic resonance (NMR) spectroscopy enable us to record thousands of metabolites of organs and tissues. Studying organisms at a molecular level contributes to an in-depth understanding of preclinical conditions of various diseases. Metabolomics reflects the dynamics of metabolism distribution, including environmental influences, allowing us to create a metabolic profile of the patient. The aim of this review was to analyze current data on metabolomic and proteomic biomarkers in the diagnosis of cardiovascular diseases. The search databases were used to select studies on the potential clinical and diagnostic application of proteomic and metabolomic markers in cardiology. The selected sources were subjected to qualitative and thematic analysis. All biomarkers were grouped according to the pathophysiological process (inflammation, blood coagulation and lipid metabolism disorders, myocardial necrosis, etc.). The association of changes in metabolomic and proteomic profiles with the activation of pathogenic processes in the cardiovascular system was demonstrated. The use of these multivariate markers, individually or in combination, will increase the accuracy of early diagnosis and the effectiveness of treatment. This article also highlights the limitations of the method and possible ways to solve them. Full article
(This article belongs to the Section Endocrinology and Metabolism Research)
Show Figures

Figure 1

21 pages, 1155 KB  
Systematic Review
Benchtop NMR in Biomedicine: An Updated Literature Overview
by Linda Fantato, Maria Salobehaj, Jacopo Patrussi, Gaia Meoni, Alessia Vignoli and Leonardo Tenori
Metabolites 2026, 16(1), 3; https://doi.org/10.3390/metabo16010003 - 22 Dec 2025
Cited by 1 | Viewed by 1599
Abstract
Background: Nuclear Magnetic Resonance (NMR) spectroscopy is a powerful analytical tool in metabolomics, but it is often hindered by the high cost and technical complexity of the machines, limiting its clinical and point-of-care applications. Recent advances in benchtop NMR technology have sought [...] Read more.
Background: Nuclear Magnetic Resonance (NMR) spectroscopy is a powerful analytical tool in metabolomics, but it is often hindered by the high cost and technical complexity of the machines, limiting its clinical and point-of-care applications. Recent advances in benchtop NMR technology have sought to overcome these barriers by providing more compact, affordable, and user-friendly instruments. This systematic review aims to assess the potential of benchtop NMR in clinical metabolomics, highlighting its practical advantages, current applications, and technological challenges relative to high-field systems. Methods: For this systematic review we searched Web of Science and PubMed databases to identify studies employing benchtop NMR spectroscopy in clinical and biomedical applications. The review focuses on works that evaluated metabolic profiling in human and animal disease contexts, compared benchtop and high-field performance, and utilized advanced data analysis methods, including multivariate and machine learning approaches. Results: Among the 74 records identified, 15 research articles were eligible, including 11 studies involving human biospecimens and 4 studies concerning animal samples. The selected works were published between 2018 and 2025. These studies demonstrated the potential clinical utility of low-field NMR in differentiating disease states such as tuberculosis, type 2 diabetes, neonatal sepsis, and chronic kidney disease, achieving diagnostic accuracies comparable to high-field instruments. Conclusions: Although limited by lower sensitivity and spectral resolution, benchtop NMR represents a significant step toward the democratization of NMR-based metabolomics. Continued hardware development, improved pulse sequences, and the integration of artificial intelligence for spectral processing and modeling are expected to enhance its analytical power and accelerate its clinical adoption. Full article
(This article belongs to the Collection Advances in Metabolomics)
Show Figures

Graphical abstract

20 pages, 3662 KB  
Article
Enhancing Signal Processing Capability with Tabu Search Algorithm Utilization for Rate-4/5 Modulation Coded Bit-Patterned Magnetic Recording
by Mutita Mattayakan, Chanon Warisarn, Jaejin Lee and Kittipon Kankhunthod
Appl. Sci. 2025, 15(24), 12944; https://doi.org/10.3390/app152412944 - 8 Dec 2025
Cited by 1 | Viewed by 490
Abstract
To meet the growing demand for higher storage capacities, bit-patterned magnetic recording (BPMR) has emerged as a leading solution for achieving ultra-high user densities (UDs). However, BPMR systems are significantly impacted by two-dimensional (2D) interferences, specifically inter-symbol interference (ISI) and inter-track interference (ITI), [...] Read more.
To meet the growing demand for higher storage capacities, bit-patterned magnetic recording (BPMR) has emerged as a leading solution for achieving ultra-high user densities (UDs). However, BPMR systems are significantly impacted by two-dimensional (2D) interferences, specifically inter-symbol interference (ISI) and inter-track interference (ITI), which can degrade the quality of the readback signal. This paper introduces a rate-4/5 constructive ITI (CITI) modulation scheme, combined with a Tabu search (TS)-based error correction algorithm, to address the limitations of conventional CITI modulation codes. In the original encoding scheme, some codewords still contain forbidden patterns within their borders. The TS algorithm enhances the performance of the outermost tracks by refining unreliable bits identified through a distance-based reliability metric, which differs from earlier TS-based detectors that were directly used for multi-track detection. A proposed soft-information adjuster is then used to correct the poor reliability of soft information, resulting in improved soft-information reliability and decoding performance. A modified TS detector is also proposed, where the single-bit criterion for selecting the number of input bits is adopted, to improve neighbor selection and better align with the signal characteristics of the inner tracks. Simulation results show that the proposed system can achieve up to 2.7 dB and 4.0 dB improvements in bit error rate (BER) at a user density (UD) of 2.4 Terabits per square inch, compared to conventional uncoded and coded systems, respectively, while also reducing computational complexity. Furthermore, the results also imply that when the recording systems must operate under fluctuations in the size and position of the bit-island, our proposed system can provide superior performance. Full article
(This article belongs to the Section Electrical, Electronics and Communications Engineering)
Show Figures

Figure 1

15 pages, 3170 KB  
Article
Measuring Relative Component Motion and Stability in Total Hip Replacements Using a Magnetic Position and Orientation Sensing System
by Oliver G. Vickers, Peter R. Culmer, Graham H. Isaac, Robert W. Kay, Matthew P. Shuttleworth, Tim N. Board and Sophie Williams
Sensors 2025, 25(23), 7280; https://doi.org/10.3390/s25237280 - 29 Nov 2025
Cited by 1 | Viewed by 958
Abstract
An instrumented total hip replacement (THR) implant capable of remote and continuous monitoring would be an attractive prospect for a surgeon to conveniently track the recovery of their patients. Measuring the relative motion of the prosthesis components would provide insight into joint kinematics [...] Read more.
An instrumented total hip replacement (THR) implant capable of remote and continuous monitoring would be an attractive prospect for a surgeon to conveniently track the recovery of their patients. Measuring the relative motion of the prosthesis components would provide insight into joint kinematics and contribute to the detection of adverse events including impingement and subluxation. The aim of this study was to develop a sensing system to measure the relative orientation and translation of the prosthesis components. A tri-axis magnetometer and a permanent magnet were integrated into clinically available THR components, forming a magnetic position and orientation sensing system. A robotic arm was used to articulate the components through controlled motion routines and record the orientation of the components. The output of the robot arm and a camera tracking system were used to validate the performance of the sensing system. The sensing system measured the relative orientation of the components to two degrees of freedom with an RMSE of <4.0° and measured the displacement of the femoral head during an impingement-driven subluxation motion with an RMSE of 0.2 mm. This proof-of-concept work has shown that magnetic sensing technology can track the position and orientation of THR components. With further development, this sensing method could feature within an instrumented THR implant. Full article
(This article belongs to the Special Issue Advanced Sensors in Biomechanics and Rehabilitation—2nd Edition)
Show Figures

Figure 1

22 pages, 2450 KB  
Review
Development Trend in Non-Destructive Techniques for Cultural Heritage: From Material Characterization to AI-Driven Diagnosis
by Mingrui Zhang, Suchi Liu, Haojian Shao, Zonghuan Ba, Jie Liu, Mǎdǎlina Georgiana Albu Kaya, Keyong Tang and Guohe Han
Heritage 2025, 8(9), 381; https://doi.org/10.3390/heritage8090381 - 16 Sep 2025
Cited by 8 | Viewed by 4375
Abstract
Cultural heritage (CH) relics are irreplaceable records of human civilization, encompassing diverse historical, technological, and artistic achievements. Extracting their structural and compositional information without affecting their physical integrity is a critical challenge. This review summarizes recent advances in non-destructive techniques (NDTs) for CH [...] Read more.
Cultural heritage (CH) relics are irreplaceable records of human civilization, encompassing diverse historical, technological, and artistic achievements. Extracting their structural and compositional information without affecting their physical integrity is a critical challenge. This review summarizes recent advances in non-destructive techniques (NDTs) for CH analysis and emphasizes the balance between the depth of analysis and conservation ethics. Techniques are broadly categorized into spectrum-based, X-ray-based, and digital-based methods. Spectroscopic techniques such as Fourier transform infrared (FTIR), Raman, and nuclear magnetic resonance (NMR) spectroscopy provide molecular-level insights into organic and inorganic components, often requiring minimal or no sampling. X-ray-based techniques, including conventional and spatially resolved XRD/XRF and total reflection XRF (TRXRF), provide powerful means for crystal and elemental analysis, including in situ pigment identification and trace material analysis. Digital-based methods include high-resolution imaging, three-dimensional modeling, data fusion, and AI-driven diagnosis to achieve the non-invasive visualization, monitoring, and virtual restoration of CH assets. This review highlights a methodology shift from traditional molecular-level detection to data-centric and AI-assisted diagnosis, reflecting the paradigm shift in heritage science. Full article
Show Figures

Figure 1

15 pages, 921 KB  
Article
Structural, Thermophysical, and Magnetic Properties of the γ-Fe4N System: Density Functional Theory and Experimental Study
by Guillermo A. Muñoz Medina, Azucena M. Mudarra Navarro, Crispulo E. Deluque Toro and Arles V. Gil Rebaza
Processes 2025, 13(8), 2402; https://doi.org/10.3390/pr13082402 - 28 Jul 2025
Cited by 2 | Viewed by 1122
Abstract
The γ-Fe4N system has a high technological relevance due to its multiple applications in the field of surface treatment against wear and corrosion of iron in steel parts, as well as in the manufacturing of high-density magnetic recording devices, [...] Read more.
The γ-Fe4N system has a high technological relevance due to its multiple applications in the field of surface treatment against wear and corrosion of iron in steel parts, as well as in the manufacturing of high-density magnetic recording devices, and so on. In the present work, we present a wide research of the structural, elastic, magnetic, vibrational, and thermophysical properties by means of the phonon analysis. For these purposes, we have compared theoretical and experimental results. The theoretical data were obtained by employing ab initio electronic structure calculations in the framework of density functional theory (DFT), and different experimental measurements, such as X-ray diffraction, magnetization measurements, and calorimetric techniques, were used to characterize the γ-Fe4N system. The resulting comparison showed an excellent agreement between the theoretical and experimental data reported. Full article
Show Figures

Figure 1

15 pages, 1954 KB  
Article
3D-Printed Helmet for Electromagnetic Articulograph Applied in the Study of Oral Physiology
by Franco Marinelli, Francisco Andrés Escobar Jara, Camila Venegas-Ocampo, Josefa Alarcón, Giannina Álvarez, Gloria Cifuentes-Suazo, Marcela Jarpa-Parra, Pablo Navarro, Gladys Morales and Ramón Fuentes Fernández
Appl. Sci. 2025, 15(14), 7913; https://doi.org/10.3390/app15147913 - 16 Jul 2025
Viewed by 1304
Abstract
Electromagnetic articulography is a technique developed for recording three-dimensional movements. It is based on magnetic induction, where small currents are induced in miniature receiver coils acting as motion sensors by means of electromagnetic fields generated by transmitter coils. This technology has been applied [...] Read more.
Electromagnetic articulography is a technique developed for recording three-dimensional movements. It is based on magnetic induction, where small currents are induced in miniature receiver coils acting as motion sensors by means of electromagnetic fields generated by transmitter coils. This technology has been applied in dental research to record mandibular movements during mastication, Posselt’s envelope of motion, and micromovements of dental prostheses. The AG501 electromagnetic articulograph (Carstens Medizinelektronik GmbH, Bovenden, Germany) provides a Head Correction (HC) procedure to eliminate head movement, which requires the reference sensors to be firmly attached to the subject’s head. If the sensors shift during the recordings, it becomes necessary to reposition them and repeat the head correction procedure. The aim of this study was to develop a 3D-printed helmet to securely fix the reference sensors to the head of a subject in the context of performing a series of recordings involving the mastication of 36 foods and the execution of Posselt’s envelope of motion. The number of HCs required was recorded for a group using the helmet and for a control group in which the sensors were attached to the subject’s head using tissue adhesive. A total of 29 recordings were conducted with and without the helmet. Without the helmet 44 HCs were required; on the other hand, with the helmet 36 HCs were required. On average, 1.5 HCs were required per session without the helmet and 1.2 HCs with the helmet, showing a non-significant difference (p < 0.05). A reduction in the number of HCs required per session was observed. However, more than one HC was still needed to complete a session. This could be addressed in future research by designing a series of helmets that adapt to different head sizes. Full article
(This article belongs to the Special Issue 3D Printed Materials Dentistry II)
Show Figures

Figure 1

13 pages, 665 KB  
Review
Emerging Technologies for Injury Identification in Sports Settings: A Systematic Review
by Luke Canavan Dignam, Lisa Ryan, Michael McCann and Ed Daly
Appl. Sci. 2025, 15(14), 7874; https://doi.org/10.3390/app15147874 - 14 Jul 2025
Viewed by 2208
Abstract
Sport injury recognition is rapidly evolving with the integration of new emerging technologies. This systematic review aims to identify and evaluate technologies capable of detecting injuries during sports participation. A comprehensive search of PUBMED, Sport Discus, Web of Science, and ScienceDirect was conducted [...] Read more.
Sport injury recognition is rapidly evolving with the integration of new emerging technologies. This systematic review aims to identify and evaluate technologies capable of detecting injuries during sports participation. A comprehensive search of PUBMED, Sport Discus, Web of Science, and ScienceDirect was conducted following the PRISMA 2020 guidelines. The review was registered on PROSPERO (CRD42024608964). Inclusion criteria focused on prospective studies involving athletes of all ages, evaluating tools which are utilised to identify injuries in sports settings. The review included research between 2014 and 2024; retrospective, conceptual, and fatigue-focused studies were excluded. Risk of bias was assessed using the Critical Appraisal Skills Program (CASP) tool. Of 4283 records screened, 70 full-text articles were assessed, with 21 studies meeting the final inclusion criteria. The technologies were grouped into advanced imaging (Magnetic Resonance Imaging (MRI), Diffusion Tensor Imaging (DFI), and Quantitative Susceptibility Mapping (QSM), with biomarkers (i.e., Neurofilament Light (NfL), Tau protein, Glial Fibrillary Acidic Protein (GFAP), Salivary MicroRNAs, and Immunoglobulin A (IgA), and sideline assessments (i.e., the King–Devick test, KD-Eye Tracking, modified Balance Error Scoring System (mBESS), DETECT, ImPACT structured video analysis, and Instrumented Mouth Guards (iMGs)), which demonstrated feasibility for immediate sideline identification of injury. Future research should improve methodological rigour through larger, diverse samples and controlled designs, with real-world testing environments. Following this guidance, the application of emerging technologies may assist medical staff, coaches, and national governing bodies in identifying injuries in a sports setting, providing real-time assessment. Full article
(This article belongs to the Special Issue Sports Injuries: Prevention and Rehabilitation)
Show Figures

Figure 1

11 pages, 662 KB  
Brief Report
ECMO Support in Pediatric Populations with the Newborn ECMOLife Centrifugal Pump
by Carlo Pace Napoleone, Ignazio Condello, Maria Teresa Cascarano, Enrico Aidala, Licia Peruzzi, Isabella Molinari, Cristina Rivoldini, Maria Stella Di Carlo, Stefania Iannandrea and Enrico Bonaveglio
Medicina 2025, 61(3), 493; https://doi.org/10.3390/medicina61030493 - 13 Mar 2025
Viewed by 2478
Abstract
Background and Objectives: Pediatric ECMO is a valid support mechanism for refractory cardiac and/or respiratory failure. Magnetic levitation technology applied to the centrifugal pump has reduced the hemolysis caused by this procedure, which can be particularly dangerous, especially in neonates and small [...] Read more.
Background and Objectives: Pediatric ECMO is a valid support mechanism for refractory cardiac and/or respiratory failure. Magnetic levitation technology applied to the centrifugal pump has reduced the hemolysis caused by this procedure, which can be particularly dangerous, especially in neonates and small children. ECMOLife, a new magnetic levitation centrifugal pump, has been introduced for these patients. Materials and Methods: Four patients were supported with the ECMOLife System in a newborn setting, with veno-venous application in two cases and veno-arterial in the other two. All parameters related to pump functioning, anticoagulation, hemolysis, and inflammation were recorded for the duration of the support. Results: All patients survived the procedure, in three cases achieving recovery, while one veno-arterial ECMO was switched to VAD, and then the patient underwent heart transplantation. All recorded parameters were compatible with clinical conditions. In particular, free haemoglobin was close to 0 g/L in all recorded samples. The possibility of monitoring pump functioning parameters, venous and arterial O2 saturation, and venous and arterial pressures creates an opportunity to check the adequacy of mechanical support for the clinical condition of the patient. Conclusions: This is the first reported experiment in a newborn setting with ECMOLife mechanical support. At present, ECMOLife represents the only system with a newborn and pediatric pump, allowing for the continuous monitoring of perfusion and hemodynamic parameters, with a large number of facilities for transportation available. Full article
(This article belongs to the Section Pediatrics)
Show Figures

Figure 1

Back to TopTop