Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (100)

Search Parameters:
Keywords = lightning protection systems

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
25 pages, 2825 KB  
Article
Transient Overvoltage Analysis and Insulation Coordination for an ±800 kV/8 GW MMC-Based Ultra-High-Voltage DC Transmission System
by Xiaorui Liu, Guoliang Zhou, Tiantian He, Lianhui Ning, Weiwen Zeng, Lingfeng Xia, Haoyuan Li, Qingxin Wang, Junyuan Zhang, Ruoxi Fan, Xinliang Liu and Hanjin Song
Electronics 2026, 15(13), 2859; https://doi.org/10.3390/electronics15132859 - 1 Jul 2026
Viewed by 322
Abstract
Facing the demand of long-distance, high-voltage and high-power transmission, the research on MMC-UHVDC (Modular Multilevel Converter based Ultra High Voltage Direct Current) has become a hot issue. This paper focuses on the ±800 kV/8 GW UHVDC transmission system to conduct simulation modelling and [...] Read more.
Facing the demand of long-distance, high-voltage and high-power transmission, the research on MMC-UHVDC (Modular Multilevel Converter based Ultra High Voltage Direct Current) has become a hot issue. This paper focuses on the ±800 kV/8 GW UHVDC transmission system to conduct simulation modelling and insulation coordination studies. First, broadband models of the main circuit and primary equipment are established to simulate and analyse the distribution characteristics of both switching and lightning transient overvoltages under typical faults. Second, based on the overvoltage severity at critical nodes, two surge arrester configuration schemes with distinct internal valve protection topologies are proposed. Finally, an Improved Fuzzy Analytic Hierarchy Process (FAHP) is introduced to perform a quantitative techno-economic evaluation of the comparative schemes. The results demonstrate that the optimised configuration successfully suppresses extreme overvoltages at vulnerable sub-module nodes, maintaining adequate insulation margins. These research findings provide a highly reliable mathematical framework and engineering reference for the safe design of UHVDC systems. Full article
(This article belongs to the Special Issue Advanced Technologies for Future Electric Power Transmission Systems)
Show Figures

Figure 1

26 pages, 10775 KB  
Review
A Review of Overvoltage Protection Technologies and Protective Devices for Wind Turbines
by Jinru Sun, Zhicheng Peng, Dongxin Liu, Zhuoyan Chen, Yihe Li, Aoyu Wang, Zijia Jiao and Xueling Yao
Energies 2026, 19(11), 2704; https://doi.org/10.3390/en19112704 - 4 Jun 2026
Viewed by 505
Abstract
Wind turbines are persistently threatened by both lightning overvoltage and switching overvoltage due to their ultra-high structure, dense power electronics, and harsh operational environments, which severely endanger the safe and stable operation of the units. This paper systematically reviews the generation mechanism, type [...] Read more.
Wind turbines are persistently threatened by both lightning overvoltage and switching overvoltage due to their ultra-high structure, dense power electronics, and harsh operational environments, which severely endanger the safe and stable operation of the units. This paper systematically reviews the generation mechanism, type characteristics, and hazards of overvoltages in wind turbines. An internal and collaborative overvoltage protection system based on lightning protection zones (LPZs) is described. Focusing on three core protective devices—metal oxide varistors (MOVs), gas discharge tubes (GDTs), and Transient Voltage Suppressors (TVSs)—the research progress in material modification, structural optimisation, and performance evolution laws is explored. Additionally, the development of series-parallel topological collaborative design for multiple devices and active-triggered intelligent protection technologies is analysed. It is highlighted that current wind turbine overvoltage protection still faces bottlenecks in standard applicability, device operating condition adaptability, and system-level collaborative design. Future research should focus on the application of a wide bandgap and nanomaterials, the improvement of test standards tailored for actual operating conditions, and the construction of multi-physics coupling simulation and active intelligent early warning protection systems, so as to provide theoretical and technical support for high-reliability overvoltage protection of large-capacity and offshore wind turbines. Full article
(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
Show Figures

Figure 1

23 pages, 4929 KB  
Article
Research on the Coordination of Surge Protectors in Communication Power Systems
by Kang Yang, Hongyan Xing, Zhoulong Wang and Linlong Shi
Energies 2026, 19(10), 2454; https://doi.org/10.3390/en19102454 - 20 May 2026
Viewed by 500
Abstract
To address the issue of coordination failure in multi-stage surge protective devices (SPDs) under lightning surges in communication power systems, this study employs traveling wave propagation theory and electromagnetic transient simulations using the PSCAD/EMTDC platform. It systematically evaluates how lightning strike location, interstage [...] Read more.
To address the issue of coordination failure in multi-stage surge protective devices (SPDs) under lightning surges in communication power systems, this study employs traveling wave propagation theory and electromagnetic transient simulations using the PSCAD/EMTDC platform. It systematically evaluates how lightning strike location, interstage cable length, and load type affect energy coordination and overvoltage response in a two-stage SPD configuration. By combining time-domain and frequency-domain analysis, the coupling mechanism of SPD conduction timing is revealed. There exists a critical length for the interstage cable to ensure coordinated operation of the SPDs. This critical length decreases with increasing surge intensity but increases significantly with greater lightning strike distance. Incorporating an appropriate series inductor can provide the necessary time delay, serving as an alternative to using a long cable. For capacitive loads, although an excessively short cable can reduce the amplitude of oscillatory voltage spikes, it aggravates the surge steepness, thereby stressing the SPD. These oscillations can be effectively suppressed by installing a damping resistor in front of the SPD2. Furthermore, the study reveals a strong coupling between energy coordination and overvoltage behavior under capacitive load conditions, indicating that the two must be jointly optimized. The parameter configurations and practical recommendations presented offer quantitative design guidance for SPD selection, cable layout, and resonance suppression in communication power systems. Full article
Show Figures

Figure 1

27 pages, 321 KB  
Article
Regulatory Governance of AI in the Generative AI Era: A Comparative Study of South Korea’s AI Basic Act and the EU AI Act for Sustainable Digital Transformation
by Jungmi Bang
Laws 2026, 15(3), 42; https://doi.org/10.3390/laws15030042 - 13 May 2026
Viewed by 2483
Abstract
This study conducts a comparative legal analysis of South Korea’s Framework Act on Artificial Intelligence (enacted January 2025, effective January 2026) and the EU AI Act (effective August 2024), focusing on the structural implications of their divergent regulatory philosophies for sustainable digital governance. [...] Read more.
This study conducts a comparative legal analysis of South Korea’s Framework Act on Artificial Intelligence (enacted January 2025, effective January 2026) and the EU AI Act (effective August 2024), focusing on the structural implications of their divergent regulatory philosophies for sustainable digital governance. Employing legal interpretive analysis (textual, systematic, and teleological) and comparative legal methodology, supplemented by risk-based regulation theory and the theory of hardening of soft norms, this paper examines three interconnected dimensions: the conceptual distinction between “high-impact” and “high-risk” AI, the legal nature of self-regulatory structures, and the potential distortion of civil liability attribution. The analysis reveals that Korea’s adoption of the “high-impact” concept, while strategically reducing compliance costs and avoiding stigma effects, generates significant legal gaps, including potential violations of the constitutional principle of clarity, a “liability lightning rod” phenomenon transferring responsibility from AI operators to frontline practitioners, and insufficient institutional prerequisites for effective self-regulation. In contrast, the EU’s ex-ante preventive framework provides greater legal certainty through direct enumeration of high-risk sectors and mandatory conformity assessments. Drawing on the growing body of EU AI Act scholarship, this paper proposes a five-step legislative model for dynamic regulatory adjustment tailored to Korea’s constitutional structure, encompassing statutory core criteria, periodic re-evaluation with parliamentary oversight, phased mandatory enforcement, and a presumption of conformity system, thereby offering a co-regulatory framework that balances innovation promotion with fundamental rights protection. Full article
22 pages, 5797 KB  
Article
Computational Investigation of Lightning Strike Damage Effects on an Aircraft Fuel Tank Cover
by Feng Yue and Xiaofeng Xue
Fibers 2026, 14(5), 46; https://doi.org/10.3390/fib14050046 - 23 Apr 2026
Viewed by 960
Abstract
Fuel vapor can be ignited by lightning through various means, particularly through hot spot formation on fuel tank skins. The wing fuel tank cover and its surrounding outer plates together form part of the aerodynamic shape of an aircraft. The lightning protection design [...] Read more.
Fuel vapor can be ignited by lightning through various means, particularly through hot spot formation on fuel tank skins. The wing fuel tank cover and its surrounding outer plates together form part of the aerodynamic shape of an aircraft. The lightning protection design of the fuel system, including wing fuel tank, is of great significance for ensuring the aircraft safety. Based on the Joule heating and implosion effect, the damage response of a composite fuel tank cover subjected to lightning strikes is analyzed in this paper. The adopted method combines electrical–thermal coupling with explicit dynamics analysis. Firstly, a finite element model of the fuel tank cover is established using electrical–thermal coupling elements, and the lightning current impact simulation is carried out under given electrical boundary conditions and thermal boundary conditions. On one hand, the ablation criterion is determined by the Joule heating effect and the sublimation temperature of materials. The thermal damage of composite materials subjected to transient high currents is obtained through transient thermal analysis. On the other hand, special implosion elements are selected according to the temperature distribution obtained from the electrical–thermal coupling analysis. The original composite material model in the implosion region needs to be replaced with a new material model described by the high-explosive material model and the JWL equation of state. The von Mises stress distribution and pressure distribution on the structure after implosion are discussed in detail. The results show that concave pits are formed near the implosion zone. Unlike the thermal damage morphology defined by the ablation criterion, the implosion effect makes the damage distribution deviate from the initial fiber direction of each layer. The implosion dynamic method reveals the internal damage and pit and bulge phenomenon around the lightning attachment area to a certain extent. Full article
Show Figures

Figure 1

20 pages, 3551 KB  
Article
GMM-Based Lightning Damage Detection for Wind Turbines Under De-Rated Operation Using the Scaled Power Curve
by Takuto Matsui, Koki Naito and Kazuo Yamamoto
Energies 2026, 19(7), 1790; https://doi.org/10.3390/en19071790 - 6 Apr 2026
Viewed by 628
Abstract
Many countries are actively promoting the large-scale deployment of wind power generation, both onshore and offshore. However, damage to wind turbines caused by winter lightning has become a growing concern in Japan. Japan has made efforts since an early stage to establish legal [...] Read more.
Many countries are actively promoting the large-scale deployment of wind power generation, both onshore and offshore. However, damage to wind turbines caused by winter lightning has become a growing concern in Japan. Japan has made efforts since an early stage to establish legal frameworks for reducing lightning damage; nevertheless, lightning damage to wind turbines remains a problem that has not been completely eradicated. After a wind turbine has been struck by lightning, it is restarted only after its structural integrity has been verified; however, the current method relies on visual inspection by workers, making accurate and rapid inspections difficult. One approach to solving this problem is to use anomaly detection techniques based on SCADA data. Research is currently underway to implement this approach. However, anomaly detection methods based on SCADA data have been criticized for their limited ability to accommodate multiple operating modes, including de-rated operation. In this study, we propose the “scaled power curve” as a robust feature that is less affected by operating modes, with its effectiveness verified through anomaly detection. This method showed improved anomaly detection accuracy compared to using the original power curve as a feature; moreover, in the present case, the method remained effective under de-rated operation. By using this feature, it is expected that a lightning damage detection model can be developed, contributing to improved availability of wind turbines. Full article
(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
Show Figures

Figure 1

18 pages, 5567 KB  
Article
Quantitative Analysis of Lightning Rod Impacts on the Radiation Pattern and Polarimetric Characteristics of S-Band Weather Radar
by Xiaopeng Wang, Jiazhi Yin, Fei Ye, Ting Yang, Yi Xie, Haifeng Yu and Dongming Hu
Remote Sens. 2026, 18(3), 392; https://doi.org/10.3390/rs18030392 - 23 Jan 2026
Cited by 1 | Viewed by 660
Abstract
Lightning rods, while essential for protecting weather radars from direct lightning strikes, act as persistent non-meteorological scatterers that can interfere with signal transmission and reception and thereby degrade detection accuracy and product quality. Existing studies have mainly focused on X-band and C-band systems, [...] Read more.
Lightning rods, while essential for protecting weather radars from direct lightning strikes, act as persistent non-meteorological scatterers that can interfere with signal transmission and reception and thereby degrade detection accuracy and product quality. Existing studies have mainly focused on X-band and C-band systems, and robust, measurement-based quantitative assessments for S-band dual-polarization radars remain scarce. In this study, a controllable tilting lightning rod, a high-precision Far-field Antenna Measurement System (FAMS), and an S-band dual-polarization weather radar (SAD radar) are jointly employed to systematically quantify lightning-rod impacts on antenna electromagnetic parameters under different rod elevation angles and azimuth configurations. Typical precipitation events were analyzed to evaluate the influence of the lightning rods on dual-polarization parameters. The results show that the lightning rod substantially elevates sidelobe levels, with a maximum enhancement of 4.55 dB, while producing only limited changes in the antenna main-beam azimuth and beamwidth. Differential reflectivity (ZDR) is the most sensitive polarimetric parameter, exhibiting a persistent positive bias of about 0.24–0.25 dB in snowfall and mixed-phase precipitation, while no persistent azimuthal anomaly is evident during freezing rain; the co-polar correlation coefficient (ρhv) is only marginally affected. Collectively, these results provide quantitative, far-field evidence of lightning-rod interference in S-band dual-polarization radars and provide practical guidance for more reasonable lightning-rod placement and configuration, as well as useful references for ZDR-oriented polarimetric quality-control and correction strategies. Full article
(This article belongs to the Section Engineering Remote Sensing)
Show Figures

Figure 1

25 pages, 7150 KB  
Article
Integrating Frequency-Spatial Features for Energy-Efficient OPGW Target Recognition in UAV-Assisted Mobile Monitoring
by Lin Huang, Xubin Ren, Daiming Qu, Lanhua Li and Jing Xu
Sensors 2026, 26(2), 506; https://doi.org/10.3390/s26020506 - 12 Jan 2026
Viewed by 730
Abstract
Optical Fiber Composite Overhead Ground Wire (OPGW) cables serve dual functions in power systems, lightning protection and critical communication infrastructure for real-time grid monitoring. Accurate OPGW identification during UAV inspections is essential to prevent miscuts and maintain power-communication functionality. However, detecting small, twisted [...] Read more.
Optical Fiber Composite Overhead Ground Wire (OPGW) cables serve dual functions in power systems, lightning protection and critical communication infrastructure for real-time grid monitoring. Accurate OPGW identification during UAV inspections is essential to prevent miscuts and maintain power-communication functionality. However, detecting small, twisted OPGW segments among visually similar ground wires is challenging, particularly given the computational and energy constraints of edge-based UAV platforms. We propose OPGW-DETR, a lightweight detector based on the D-FINE framework, optimized for low-power operation to enable reliable detection. The model incorporates two key innovations: multi-scale convolutional global average pooling (MC-GAP), which fuses spatial features across multiple receptive fields and integrates spectrally motivated features for enhanced fine-grained representation, and a hybrid gating mechanism that dynamically balances global and spatial features while preserving original information through residual connections. By enabling real-time inference with minimal energy consumption, OPGW-DETR addresses UAV battery and bandwidth limitations while ensuring continuous detection capability. Evaluated on a custom OPGW dataset, the S-scale model achieves 3.9% improvement in average precision (AP) and 2.5% improvement in AP50 over the baseline. By mitigating misidentification risks, these gains improve communication reliability. As a result, uninterrupted grid monitoring becomes feasible in low-power UAV inspection scenarios, where accurate detection is essential to ensure communication integrity and safeguard the power grid. Full article
(This article belongs to the Section Internet of Things)
Show Figures

Figure 1

39 pages, 1059 KB  
Systematic Review
Ground Enhancement Materials for Grounding Systems: A Systematic Review of Factors, Technologies and Advances
by Hugo Martínez Ángeles, Cesar Augusto Navarro Rubio, Luis Angel Iturralde Carrera, Leonel Díaz-Tato, José Gabriel Ríos Moreno, Mario Trejo Perea, Roberto Valentín Carrillo-Serrano and Juvenal Rodríguez-Reséndiz
Technologies 2026, 14(1), 49; https://doi.org/10.3390/technologies14010049 - 8 Jan 2026
Cited by 3 | Viewed by 2854
Abstract
Grounding Systems (GS) play a critical role in electrical safety, lightning protection, and the reliable operation of power and renewable energy infrastructures, particularly in high-resistivity soils. In this context, Ground Enhancement Materials (GEM) are widely used to reduce soil resistivity and improve grounding [...] Read more.
Grounding Systems (GS) play a critical role in electrical safety, lightning protection, and the reliable operation of power and renewable energy infrastructures, particularly in high-resistivity soils. In this context, Ground Enhancement Materials (GEM) are widely used to reduce soil resistivity and improve grounding performance. This systematic review analyzes and synthesizes recent advances (2018–2025) in GEM applied to GS, with emphasis on their electrical performance, durability, and environmental sustainability. The review covers conventional GEM, industrial waste-derived materials, and hybrid formulations, evaluating their effectiveness under different soil types and moisture conditions. Comparative analysis of the literature indicates that GEM derived from industrial byproducts and hybrid composites often exhibit superior long-term resistivity reduction due to enhanced moisture retention and material-soil interactions, especially in clay-rich and heterogeneous soils. Sustainability considerations such as environmental impact, material availability, and long-term stability are increasingly influencing GEM selection and design. Overall, this review provides a structured framework for understanding the factors governing GEM performance while highlighting current trends, challenges, and future research directions in the development of sustainable grounding solutions. Full article
(This article belongs to the Special Issue Technological Advances in Science, Medicine, and Engineering 2025)
Show Figures

Figure 1

30 pages, 14158 KB  
Article
The Three-Dimensional Analytical Modeling of Lightning-Induced Heat Diffusion: The Critical Roles of the Continuing Current and Lightning Channel Radius in Structural Damage
by Konrad Sobolewski and Piotr Strużewski
Appl. Sci. 2026, 16(1), 452; https://doi.org/10.3390/app16010452 - 31 Dec 2025
Cited by 2 | Viewed by 1410
Abstract
The utilization of metal roofing as natural air terminals is a standard practice in lightning protection; however, the risk of thermal perforation and subsequent ignition of internal hazardous atmospheres remains a critical safety concern. While current standards (e.g., IEC 62305) primarily focus on [...] Read more.
The utilization of metal roofing as natural air terminals is a standard practice in lightning protection; however, the risk of thermal perforation and subsequent ignition of internal hazardous atmospheres remains a critical safety concern. While current standards (e.g., IEC 62305) primarily focus on material thickness and total charge (Q), this study demonstrates that these parameters alone are insufficient for predicting burn-through failure. We present a comprehensive electrothermal analysis based on the method of images to simulate three-dimensional heat diffusion in finite-thickness plates (0.5–7 mm) made of aluminum, copper, and steel. Unlike simplified 1D models, our approach considers the spatial distribution of the heat source and the varying depth of the thermal penetration. The results confirm that the continuing current component (Qlong200 C) is the primary driver of volumetric melting. Crucially, the sensitivity analysis reveals that the lightning channel radius (rmbo) acts as a governing factor for perforation risk; a reduction in the lightning channel radius from 5 mm to 2 mm can shift the outcome from minor surface heating to complete perforation for thin sheets (0.5 mm), even under identical charge conditions. This paper identifies a “safety gap” in current engineering practices, demonstrating that neglecting this parameter constriction effect results in an underestimation of the thermal threat. The proposed analytical model provides a precise tool for determining the safety margins of natural air terminals, offering direct applicability for designing lightning protection systems in high-risk industrial facilities. Full article
(This article belongs to the Section Applied Thermal Engineering)
Show Figures

Figure 1

27 pages, 1773 KB  
Article
The Mathematical Modeling of a Lightning Strike in an HVAC Line Considering the Modified Hamilton–Ostrogradsky Principle
by Vitaliy Levoniuk, Andriy Chaban, Paweł Czaja, Aleksander Dydycz, Andrzej Szafraniec, Roman Kwiecień and Małgorzata Górska
Energies 2025, 18(24), 6599; https://doi.org/10.3390/en18246599 - 17 Dec 2025
Cited by 1 | Viewed by 740
Abstract
Based on the modified Hamilton–Ostrogradsky principle, a mathematical model of a distributed-parameter high-voltage HVAC line that includes lightning shield wires is proposed. A partial differential equation of a five-wire power line is produced as a result. Therefore, a methodology for looking for boundary [...] Read more.
Based on the modified Hamilton–Ostrogradsky principle, a mathematical model of a distributed-parameter high-voltage HVAC line that includes lightning shield wires is proposed. A partial differential equation of a five-wire power line is produced as a result. Therefore, a methodology for looking for boundary conditions of a long line equation in the five-wire version is proposed here. A mathematical model is introduced as an example of a section of a power line that consists of a high-voltage long line that includes shield wires operating in an equivalent concentrated-parameter power system presented in its circuit version. The system is described with both partial and ordinary derivative differential equations. Poincaré boundary conditions of the third type are applied to solve the state equations of the object discussed. A discrete line model is thus presented, described with ordinary differential equations based on the well-known straight-line method. Transient processes across the system are analysed exactly at the moment of a lightning strike against a shield wire in the middle section of the line. To this end, a mathematical lightning strike model is developed by means of cubic spline interpolation. The original system of differential equations is integrated into the implicit Euler method, considering the Seidel method. The end results of the computer simulation are presented graphically and analysed. The results show the effectiveness of the proposed method of analysing transients across ultra-high-voltage lines that include lightning protection wires and can serve as accurate calculations of power supply lightning protection at the stages of design and production. Full article
Show Figures

Figure 1

13 pages, 2028 KB  
Article
Study on Transient Overvoltage and Surge Arrester Electrical Stresses in Offshore Wind Farms Under Multiple Lightning Strokes
by Jie Zhang, Yong Wang, Jun Xiong, Junxiang Liu, Lu Zhu, Chao Huang, Jianfeng Shi and Yongxia Han
J. Mar. Sci. Eng. 2025, 13(12), 2307; https://doi.org/10.3390/jmse13122307 - 4 Dec 2025
Cited by 2 | Viewed by 889
Abstract
Lightning strikes are a major cause of wind turbine (WT) damage, with approximately 80% of cloud-to-ground lightning strikes exhibiting a multi-stroke characteristic. Therefore, studying the transient overvoltages induced by multiple lightning strokes is essential for the effective lightning protection of offshore WTs. Firstly, [...] Read more.
Lightning strikes are a major cause of wind turbine (WT) damage, with approximately 80% of cloud-to-ground lightning strikes exhibiting a multi-stroke characteristic. Therefore, studying the transient overvoltages induced by multiple lightning strokes is essential for the effective lightning protection of offshore WTs. Firstly, a multiple-stroke lightning current model representative of Guangdong Province, China, is established based on data from the lightning location system and rocket-triggered lightning experiments. Simulations are then employed to analyze the transient overvoltage of a Guangdong offshore wind farm under multiple lightning strikes. Simulation results indicate that when a WT is subjected to a two-stroke lightning flash, with current amplitudes corresponding to a cumulative probability density of approximately 1%, the surge arrester A1 must be configured with four parallel columns to ensure the insulation safety of the equipment without sustaining damage. Additionally, adequate electrical clearance must be maintained between the power cable and the tower wall, or alternatively, a high-strength insulating material may be applied over the cable armor to prevent flashover. Moreover, it is observed that the front time of the impulse current flowing through the surge arrester is approximately 2 μs, significantly shorter than the front time specified in IEC 60099-4 for the repetitive charge transfer capability test of ZnO varistors. Hence, it is essential to consider local lightning intensity and distribution characteristics when studying the transient overvoltages in offshore wind farms, optimizing surge arrester configurations, and assessing the impulse withstand performance of ZnO varistors, in order to ensure the safe and stable operation of offshore WTs. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

21 pages, 1677 KB  
Article
Assessment of Lightning Activity and Early Warning Capability Using Near-Real-Time Monitoring Data in Hanoi, Vietnam
by Hoang Hai Son, Nguyen Xuan Anh, Tran Hong Thai, Pham Xuan Thanh, Pham Le Khuong, Hiep Van Nguyen, Do Ngoc Thuy, Bui Ngoc Minh, Nguyen Nhu Vinh, Duong Quang Ve, Hung Mai Khanh, Dang Dinh Quan and Tien Du Duc
Atmosphere 2025, 16(12), 1335; https://doi.org/10.3390/atmos16121335 - 26 Nov 2025
Viewed by 1320
Abstract
This study investigates lightning activity and evaluates a near-real-time lightning warning system for the inner Hanoi area, using data collected during 2020–2024 from the Strike Guard (SG) and EFM-100C instruments located in Chuong My, Hanoi, Vietnam. Lightning detection data were incorporated with rainfall [...] Read more.
This study investigates lightning activity and evaluates a near-real-time lightning warning system for the inner Hanoi area, using data collected during 2020–2024 from the Strike Guard (SG) and EFM-100C instruments located in Chuong My, Hanoi, Vietnam. Lightning detection data were incorporated with rainfall and lightning location information from the Vietnam Meteorological and Hydrological Administration (VNMHA) for quality checking. The SG data over the research area revealed clear diurnal and seasonal variations, with lightning most frequent in the late afternoon and two major peaks in June and September corresponding to the summer monsoon. A combined warning method using EFM-100C electric field measurements and SG alert states achieved an average lead time of 15 min, a Probability of Detection (POD) of 82.22%, a Critical Success Index (CSI) of 76.55%, an F1 score of 86.72%, and a False Alarm Ratio (FAR) of 8.26%. These results demonstrate that integrating electric field and optical–electromagnetic measurements can provide effective localized lightning warnings for the urban areas. The approach is cost-efficient, operationally feasible, and particularly valuable for protecting critical infrastructure regions, supporting enhanced lightning safety and disaster mitigation in northern Vietnam. Full article
(This article belongs to the Section Meteorology)
Show Figures

Figure 1

17 pages, 2315 KB  
Article
A Line-Mode Current Slope-Based Protection Scheme for Pole-to-Pole Short-Circuit Faults in DC Distribution Networks
by Wei Jin, Shiguang Feng and Yuping Lu
Symmetry 2025, 17(11), 1942; https://doi.org/10.3390/sym17111942 - 13 Nov 2025
Viewed by 702
Abstract
DC distribution networks exhibit inherent symmetry in their balanced power distribution and modular structure, offering high operational flexibility and making them particularly suitable for the integration of distributed generation and modern loads. This symmetric framework positions DC networks as a vital component of [...] Read more.
DC distribution networks exhibit inherent symmetry in their balanced power distribution and modular structure, offering high operational flexibility and making them particularly suitable for the integration of distributed generation and modern loads. This symmetric framework positions DC networks as a vital component of new power systems and a key development direction for future power supply systems in industrial and mining enterprises. However, pole-to-pole short-circuit faults disrupt this symmetry, characterized by low system damping, high fault currents, and extremely rapid current rise rates, which pose serious threats to system security and necessitate ultra-fast fault clearance. To address this issue, this paper proposes a novel pilot protection scheme inspired by symmetry principles, based on the slope of the line-mode current for pole-to-pole short-circuit faults in DC distribution networks. First, an equivalent circuit of the system before converter blocking under a pole-to-pole fault is established, and an analytical expression of the fault current is derived, incorporating symmetric analysis of modal components. Subsequently, the variation trends, amplitudes, and phase characteristics of the fault current under faults occurring in different zones of the DC line are analyzed from the perspective of modal symmetry, highlighting the symmetric and asymmetric behaviors of line-mode and zero-mode currents. Furthermore, considering the distinct symmetric properties of these currents during lightning disturbances and pole-to-pole faults, the least squares method is employed to perform linear fitting on the line-mode current, thereby capturing its symmetric variation trend. A pilot protection scheme utilizing the slope of the line-mode current is then proposed, leveraging symmetry in fault discrimination. Finally, simulation models built in MATLAB/Simulink (R2022a) are used for validation. The results demonstrate that the proposed protection method can quickly identify faults within 1.5 ms while exhibiting strong tolerance to a 20 Ω transitional resistance and 50 dB signal noise, indicating good feasibility and broad applicability, with symmetry-based analysis enhancing robustness. Full article
Show Figures

Figure 1

17 pages, 5046 KB  
Article
Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network
by Song Zhang, Xiaobin Xiao, Lei Jia, Huaifei Chen, Lu Qu, Chakhung Yeung, Yuxuan Ding and Yaping Du
Energies 2025, 18(19), 5097; https://doi.org/10.3390/en18195097 - 25 Sep 2025
Cited by 2 | Viewed by 1148
Abstract
Among various failure causes, lightning overvoltage represents the most significant threat to overhead distribution lines, which serve as critical components in power systems. This study uses the hybrid partial element equivalent circuit (PEEC) multi-conductor transmission line (MTL) method to perform overvoltage simulations and [...] Read more.
Among various failure causes, lightning overvoltage represents the most significant threat to overhead distribution lines, which serve as critical components in power systems. This study uses the hybrid partial element equivalent circuit (PEEC) multi-conductor transmission line (MTL) method to perform overvoltage simulations and investigate lightning risk distribution along distribution lines developed from a real 10 kV distribution networks in Guizhou, China. The results of the rocket-triggered lightning observation verify the accuracy of the hybrid method for direct lightning simulation. Combining the Monte Carlo method with the electro-geometric model (EGM), the impact of differential protection configurations on annual lightning flashover rates is analyzed. The results demonstrate that lightning strikes on phase wires generate high-magnitude overvoltages but with limited spatial influence, resulting in fewer pole flashovers. Conversely, strikes on poles produce lower overvoltage peaks but affect wider areas, leading to significantly more flashovers. Using annual flashover rates as the risk evaluation metric, the line topologies into high-risk, medium-risk, and other low-risk areas are classified. Targeting an annual flashover rate below 0.4 as the design objective, the configuration schemes of the arresters are progressively optimized. This risk-based approach provides an effective reference framework for differential protection design of distribution line safeguards. Full article
Show Figures

Figure 1

Back to TopTop