Search Results (74)

Search Parameters:
Keywords = lightning current measurement

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 5086 KB  
Article
Kerr-Based Interrogation of Lightning-Impulse Field Transients in Oil–Cellulose Composites and Their Interfacial Charging Effect
by Xiaolin Zhao, Haoxuan Zhang, Chunjia Gao, Yuwei Zhong, Xiang Zhao, Bo Qi and Shuqi Zhang
Processes 2026, 14(3), 551; https://doi.org/10.3390/pr14030551 - 4 Feb 2026
Viewed by 512
Abstract
To address the stringent insulation safety requirements of modern high-voltage transformers, accurately characterizing the transient electric field is critical. However, a significant problem remains: current engineering models typically rely on static capacitive distributions, failing to capture the dynamic electric field distortion induced by [...] Read more.
To address the stringent insulation safety requirements of modern high-voltage transformers, accurately characterizing the transient electric field is critical. However, a significant problem remains: current engineering models typically rely on static capacitive distributions, failing to capture the dynamic electric field distortion induced by rapid space charge injection under lightning impulses. Therefore, a non-contact spatial electric field measurement method based on the optical Kerr effect was employed to analyze the influence of electrode material, voltage amplitude, and wavefront time. Unlike traditional simulation models that often assume constant mobility and focus solely on the shielding effect, this study reveals a non-monotonic electric field evolution driven by a ‘Static-Dynamic’ mode transition. The proposed model highlights two critical breakthroughs: (1) Mechanism Innovation: It experimentally verifies that charge injection is governed by the ion charge-to-mass ratio rather than just the work function, leading to a newly identified field enhancement phase during the wavefront that overcomes the limitations of capacitive models that underestimate transient stress. (2) Parameter Quantification: Precise spatiotemporal thresholds are established—negative charges traverse the gap within ~200 ns, while positive charges require ~10 μs to reach equilibrium. These findings provide experimentally calibrated time constants for simulation correction and offer new criteria for optimizing electrode materials in UHV transformers to mitigate transient field distortion. Full article
(This article belongs to the Section Materials Processes)
Show Figures

Figure 1

14 pages, 2474 KB  
Article
Simulation-Based Analysis of the Heating Behavior of Failed Bypass Diodes in Photovoltaic-Module Strings
by Ibuki Kitamura, Ikuo Nanno, Norio Ishikura, Masayuki Fujii, Shinichiro Oke and Toshiyuki Hamada
Energies 2026, 19(2), 472; https://doi.org/10.3390/en19020472 - 17 Jan 2026
Viewed by 540
Abstract
With the expansion of photovoltaic (PV) systems, failures of bypass diodes (BPDs) embedded in PV modules can degrade the power-generation performance and pose safety risks. When a BPD fails, current circulates within the module, leading to overheating and eventual burnout of the failed [...] Read more.
With the expansion of photovoltaic (PV) systems, failures of bypass diodes (BPDs) embedded in PV modules can degrade the power-generation performance and pose safety risks. When a BPD fails, current circulates within the module, leading to overheating and eventual burnout of the failed BPD. The heating characteristics of a BPD depend on its fault resistance, and although many modules are connected in series in actual PV systems, the heating risk at the module-string level has not been sufficiently evaluated to date. In this study, a numerical simulation model is constructed to reproduce the operation of PV modules and module strings containing failed BPDs, and its validity is verified through experiments. The validated numerical simulation results quantitatively illustrate how series-connected PV modules modify the fault-resistance dependence of BPD heating under maximum power-point operation. The results show that, under maximum power-point operation, the fault resistance at which BPD heating becomes critical shifts depending on the number of series-connected modules examined, while the magnitude of the maximum heating decreases as the string length increases. The heat generated in a BPD at the maximum power point decreases as the number of series-connected modules increases for the representative string configurations analyzed. However, under open-circuit conditions due to power-conditioner abnormalities, the power dissipated in the failed BPD increases significantly, posing a very high risk of burnout. Considering that lightning strikes are one of the major causes of BPD failure, adopting diodes with higher voltage and current ratings and improving the thermal design of junction boxes are effective measures to reduce BPD failures. The simulation model constructed in this study, which was experimentally validated for short PV strings, can reproduce the electrical characteristics and heating behaviors of PV modules and strings with BPD failures with accuracy sufficient for comparative and parametric trend analysis, and serves as a practical tool for system-level safety assessment, design considerations, and maintenance planning within the representative configurations analyzed. Full article
Show Figures

Figure 1

18 pages, 6097 KB  
Article
Impact Characteristic Analysis of Tower Foundation Under Concealed Conductive Paths with Grounding Grid Based on a Scaled Model
by Ziheng Pu, Ruize Qin, Peng Li and Tian Wu
Appl. Sci. 2025, 15(22), 12143; https://doi.org/10.3390/app152212143 - 16 Nov 2025
Viewed by 630
Abstract
Concealed conductive connections between a transmission tower’s grounding grid and its foundation can cause a portion of the lightning strike current to enter the foundation and concentrate at the concealed conduction locations, thereby increasing the risk of foundation deterioration. To investigate the impact [...] Read more.
Concealed conductive connections between a transmission tower’s grounding grid and its foundation can cause a portion of the lightning strike current to enter the foundation and concentrate at the concealed conduction locations, thereby increasing the risk of foundation deterioration. To investigate the impact characteristics of such currents on the foundation under this operating condition, this study first establishes an electro-thermal-mechanical coupled finite-element model of the tower foundation that incorporates a subsurface concealed conductive loop, and compares the foundation’s temperature rise and mechanical characteristics under lightning currents and under power-frequency follow currents. The results indicate that power-frequency follow current poses a substantially greater hazard to the foundation than lightning current. Based on similarity theory, scaling laws for the foundation subjected to the impacts of power-frequency follow current are then derived. Considering that the intrinsic electro-thermal properties of the foundation cannot be altered in the scaled model, a parameter correction method is proposed according to quasi-similarity criteria. The corrected scaled-model results are compared with those of the prototype in simulation, and principal indicators exhibit deviations within 3%. A physical scaled model was subsequently designed and fabricated for impact testing, and ultrasonic inspection was used to assess potential damage in the concealed conduction region. The results show that under the action of power-frequency follow currents, the maximum temperature at the concealed conductive region reaches 124 °C, with deviations of 2.83% from the prototype simulation and 3.58% from the scaled-model simulation. The tower foundation was subjected to 20 power-frequency follow current impacts. After each impact and subsequent cooling, ultrasonic measurements of wave propagation velocity at the concealed conduction center decreased from 3.797 km/s to 3.571 km/s. The observed reduction in wave speed indicates a loss of local concrete structural integrity and suggests the risk of performance degradation and initiation of microcracks. These findings provide a reference basis for assessing the safety of tower foundations under concealed conduction conditions. Full article
Show Figures

Figure 1

27 pages, 3406 KB  
Article
Simulation-Based Framework for Backflashover Rate Estimation in High-Voltage Transmission Lines Integrating Monte-Carlo, ATP-EMTP, and Leader Progression Model
by André T. Lobato, Liliana Arevalo, Rodolfo A. R. Moura, Marco Aurélio O. Schroeder and Vernon Cooray
Energies 2025, 18(21), 5670; https://doi.org/10.3390/en18215670 - 29 Oct 2025
Cited by 2 | Viewed by 1270
Abstract
Lightning-induced backflashovers pose significant risks to high-voltage transmission systems, particularly in high lightning activity regions. Conventional backflashover rate (BFR) estimation methods rely on simplified empirical formulas that lack accuracy in complex scenarios. This paper presents a comprehensive simulation framework integrating (i) a Simulation-Based [...] Read more.
Lightning-induced backflashovers pose significant risks to high-voltage transmission systems, particularly in high lightning activity regions. Conventional backflashover rate (BFR) estimation methods rely on simplified empirical formulas that lack accuracy in complex scenarios. This paper presents a comprehensive simulation framework integrating (i) a Simulation-Based Leader Progression Model (SB-LPM) implemented in COMSOL Multiphysics–MATLAB to evaluate lightning attachment through detailed electrostatic field analysis and streamer-leader dynamics, (ii) ATP-EMTP electromagnetic transient simulations incorporating multi-component Heidler function current waveforms, calibrated to regional lightning measurements, and (iii) a Monte Carlo analysis for statistical assessment of backflashover susceptibility. Applied to a representative 138 kV transmission line in Minas Gerais, Brazil, the framework shows that BFR results are highly sensitive to tower-footing impedance and attachment model selection. The SB-LPM yields systematically different predictions compared to traditional electrogeometric models, yielding approximately 10% lower BFR estimates at 20 Ω grounding impedance relative to the widely used Eriksson model. The framework enables comprehensive lightning performance assessment by incorporating geometry-sensitive attachment modeling, realistic current waveform synthesis, and detailed system transient response, providing valuable insights for transmission line insulation coordination studies. Full article
(This article belongs to the Topic EMC and Reliability of Power Networks)
Show Figures

Figure 1

19 pages, 4254 KB  
Article
Study on the Failure Causes and Improvement Measures of Arresters in 10 kV Distribution Transformer Areas
by Taishan Hu, Yuanzhi Wu, Zhiming Liao, Gang Liu, Shangmao Hu, Yongxia Han, Lu Qu and Licheng Li
Energies 2025, 18(17), 4501; https://doi.org/10.3390/en18174501 - 25 Aug 2025
Cited by 2 | Viewed by 1459
Abstract
In recent years, arresters in 10 kV distribution transformer areas of the Guangdong power grid have exhibited a rising trend of premature failures, posing a serious threat to distribution network reliability. This paper studied the failure causes of arresters through performance tests on [...] Read more.
In recent years, arresters in 10 kV distribution transformer areas of the Guangdong power grid have exhibited a rising trend of premature failures, posing a serious threat to distribution network reliability. This paper studied the failure causes of arresters through performance tests on failed arresters and through deterioration tests on new arresters and their prorated sections under typical operating stresses. The failed arresters and their internal varistors displayed varying degrees of physical damage and pronounced degradation in electrical performance, characterized by a strong polarity effect on the DC reference voltage (U1mA), elevated DC leakage current (IL) and resistive current (iR), and excessive residual voltage (U5kV). In the lightning impulse test, varistors primarily showed pinhole-type damage and significant polarity effects on ΔU1mA. In the AC aging test, ΔU5kV increased markedly. In the water immersion test, varistors exhibited salt deposits and aluminum electrode blackening, with ΔU1mA decreasing, while IL and ΔiR increased significantly. Overall, internal moisture superimposed on other operating stresses was identified as a major internal cause of arrester failure, while pollution flashover of the housing was considered the primary external factor. Corresponding improvement measures in material optimization, testing and inspection, and operation and maintenance are proposed to enhance arrester reliability. Full article
Show Figures

Figure 1

16 pages, 3781 KB  
Article
Review of NFPA 780 Standard Compliance for Improved Lightning Protection in Indonesia’s Oil and Gas Industry
by Bryan Denov and Reynaldo Zoro
Energies 2025, 18(15), 4002; https://doi.org/10.3390/en18154002 - 28 Jul 2025
Cited by 3 | Viewed by 4677
Abstract
Lightning represents a critical danger to facilities such as oil tank farms, with the potential to cause major explosive incidents. To address this risk, Indonesia’s oil and gas industry has adopted the NFPA 780 Standard for lightning protection systems. However, tank explosions and [...] Read more.
Lightning represents a critical danger to facilities such as oil tank farms, with the potential to cause major explosive incidents. To address this risk, Indonesia’s oil and gas industry has adopted the NFPA 780 Standard for lightning protection systems. However, tank explosions and refinery disruptions caused by lightning strikes continue to occur annually, highlighting the need to reassess the standard’s self-protection criteria, particularly in Indonesia’s tropical climate. The NFPA 780 standard was primarily developed based on lightning characteristics in subtropical regions. This study evaluates its effectiveness in tropical environments, where lightning parameters such as peak currents, frequencies, and ground flash densities differ significantly. By analyzing specific incidents of tank explosions in Indonesia, the research reveals that compliance with the NFPA 780 standard alone may not be adequate to protect critical infrastructure. To address these challenges, this study proposes a novel approach to lightning protection by designing solutions tailored to the unique characteristics of tropical climates. By incorporating local lightning parameters, the proposed measures aim to enhance safety and resilience in oil and gas facilities. This research provides a framework for adapting international standards to regional needs, improving the effectiveness of lightning protection in tropical environments. Full article
(This article belongs to the Topic EMC and Reliability of Power Networks)
Show Figures

Figure 1

14 pages, 3344 KB  
Article
Current Sensor with Optimized Linearity for Lightning Impulse Current Measurement
by Wenting Li, Yinglong Diao, Feng Zhou, Zhaozhi Long, Shijun Xie, Jiawei Fan, Kangmin Hu and Zhehao Wang
Sensors 2025, 25(14), 4516; https://doi.org/10.3390/s25144516 - 21 Jul 2025
Cited by 1 | Viewed by 1154
Abstract
Impulse current measurement technology is widely used in various applications, including lightning protection monitoring in power systems, welding current measurement in aircraft and shipbuilding industries, as well as high-current measurement in pulsed power systems. With the advancement of industrial technology, the measurement range [...] Read more.
Impulse current measurement technology is widely used in various applications, including lightning protection monitoring in power systems, welding current measurement in aircraft and shipbuilding industries, as well as high-current measurement in pulsed power systems. With the advancement of industrial technology, the measurement range of impulse currents has continuously expanded, reaching levels as high as mega-amperes (MA). The calibration of the scale factor for impulse current measurement devices is determined through comparison with standard measurement devices. Developing high-accuracy impulse current measurement devices and accurately judging their characteristics are prerequisites for ensuring the precise calibration of impulse current values. This paper introduces two different types of high-impulse current measurement devices. Experimental studies were conducted on the scale factor and response characteristics of the sensors. The scale factor extension calibration method for sensors under high currents of more than 100 kA has also been introduced. Test results indicate that the developed impulse current measurement devices can serve as standard measurement devices for high impulse current measurement. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

26 pages, 6795 KB  
Article
Analysis of Time-Domain Characteristics of Microsecond-Scale Repetitive Pulse Discharge Events in Lightning
by Jinxing Shen, Zheng Sun, Lihua Shi and Shi Qiu
Atmosphere 2025, 16(5), 606; https://doi.org/10.3390/atmos16050606 - 16 May 2025
Cited by 2 | Viewed by 1730
Abstract
To clarify the background of multiple burst (MB) specifications in the aviation lightning test standards, a broadband lightning electromagnetic field measurement system was employed to collect 91 sets of VLF/LF band nature flash data. A total of 719 typical repetitive pulse (RP) groups [...] Read more.
To clarify the background of multiple burst (MB) specifications in the aviation lightning test standards, a broadband lightning electromagnetic field measurement system was employed to collect 91 sets of VLF/LF band nature flash data. A total of 719 typical repetitive pulse (RP) groups were identified, and 163,589 single pulse samples were analyzed statistically. The variational mode decomposition (VMD) method and a trend-free correlation on index (TFCI) were used to extract RPs from the slowly varying trends and high-frequency noises from the measured data. The time-domain characteristics of four kinds of RPs corresponding to the lightning discharge events—initial breakdown pulse (IBP), regular pulse bursts (RPB), chaotic pulse train (CPT), and dart-stepped leader (DSL)—were investigated. By comparing previous statistics and the definition in current international aviation standards, the intrinsic correlation between RPs and the defined parameters of MBs was explored. New recommendations for the MB test standard were subsequently proposed. Full article
(This article belongs to the Section Upper Atmosphere)
Show Figures

Figure 1

15 pages, 8092 KB  
Article
Autonomous Lightning Strike Detection and Counting System Using Rogowski Coil Current Measurement
by Arthur F. Andrade, Giovanny M. B. Galdino, Ronimack T. Souza, Newton S. S. M. Fonseca, Antonio F. Leite Neto, Edson G. Costa and Eden L. Carvalho Junior
Sensors 2025, 25(8), 2563; https://doi.org/10.3390/s25082563 - 18 Apr 2025
Cited by 1 | Viewed by 2206
Abstract
Lightning strikes are a leading cause of outages on overhead transmission lines, significantly compromising power system reliability. Consequently, monitoring lightning activity is critical to mitigate its impact on lines with high outage rates. This study presents an autonomous lightning strike counter system utilizing [...] Read more.
Lightning strikes are a leading cause of outages on overhead transmission lines, significantly compromising power system reliability. Consequently, monitoring lightning activity is critical to mitigate its impact on lines with high outage rates. This study presents an autonomous lightning strike counter system utilizing a split-core Rogowski coil for non-invasive current measurement on transmission towers. The system combines the Rogowski coil with an active integrator circuit to reconstruct the incident current waveform from the coil voltage signal. A microcontroller-based processing unit records strike occurrences and classifies them by amplitude using predefined thresholds. Laboratory tests were carried out to evaluate the performance of the Rogowski coil and integrator circuit, validating the system accuracy in detecting current pulses associated with lightning strikes. Underway field tests will assess the sensor’s reliability during long-term autonomous operation on 345-kV transmission towers. The results demonstrate that the proposed system represents a practical and cost-effective solution for lightning monitoring in remote areas, contributing to enhanced data collection for engineering studies and improved reliability of electrical infrastructure. Full article
(This article belongs to the Special Issue Sensors Technology Applied in Power Systems and Energy Management)
Show Figures

Figure 1

19 pages, 33574 KB  
Article
Mechanical and Thermal Contributions to the Damage Suffered by an Aeronautical Structure Subjected to an Intense and Sudden Electrical Discharge
by Bryan Better, Aboulghit El Malki Alaoui, Christine Espinosa, Michel Arrigoni, Nathan Menetrier, Chabouh Yazidjian, Serge Guetta, Frédéric Lachaud, Christian Jochum, Michel Boustie and Didier Zagouri
Aerospace 2025, 12(3), 235; https://doi.org/10.3390/aerospace12030235 - 14 Mar 2025
Cited by 3 | Viewed by 1749
Abstract
Lightweight aeronautical structures and power generation structures such as wind turbines are fitted with protected external layers designed and certified to withstand severe climatic events such as lightning strikes. During these events, high currents flow through the structural protection but are likely to [...] Read more.
Lightweight aeronautical structures and power generation structures such as wind turbines are fitted with protected external layers designed and certified to withstand severe climatic events such as lightning strikes. During these events, high currents flow through the structural protection but are likely to induce effects deeper in the supporting composite material and could even reach or perforate pressurized tanks. In situ measurements are hard to achieve during current delivery due to the severe electromagnetic conditions, and the lightning strike phenomenon on these structures is not yet fully investigated. To gain a better understanding of the physics involved, similarities in direct damage between lightning-struck samples and those subjected to pulsed lasers and an electron gun are analyzed. These analyses show the inability of a pure mechanical contribution to fully reproduce the shape of the delamination distribution of lightning strikes. Conversely, the similarities in effect and damage with the thermomechanical contribution of electron beam deposition are highlighted, particularly the increase in core delamination due to the paint and the apparent similarities in delamination distribution. Full article
Show Figures

Figure 1

12 pages, 3372 KB  
Article
Lightning Current Distribution of the First and Subsequent Strokes Based on the Lightning Location System: Survey in Yunnan Power Grid
by Yutang Ma, Hongchun Shu, Changxin Xiao, Gaohui Yang, Chengwei Xie, Mengmeng Zhu and Pulin Cao
Atmosphere 2025, 16(1), 15; https://doi.org/10.3390/atmos16010015 - 26 Dec 2024
Cited by 2 | Viewed by 3295
Abstract
Lightning is an electrical discharge phenomenon in the atmosphere caused by charge separation in clouds, which is divided into cloud-to-ground (CG) and cloud-to-cloud (CC) lightning. In recent years, research on the characteristics of multiple-stroke ground lightning and the amplitude of lightning currents has [...] Read more.
Lightning is an electrical discharge phenomenon in the atmosphere caused by charge separation in clouds, which is divided into cloud-to-ground (CG) and cloud-to-cloud (CC) lightning. In recent years, research on the characteristics of multiple-stroke ground lightning and the amplitude of lightning currents has attracted significant attention. The amplitude of lightning currents serves as fundamental data for lightning protection in power systems. Its accurate measurement is crucial for designing and safeguarding power systems. This paper obtains data from a lightning location system and analyzes the probability density distribution of lightning current amplitudes. It is found that the median of lightning currents gradually decreases with an increasing number of multiple strokes, and there is a trend in the change of lightning current steepness. As the number of strokes increases, the median value of amplitude distribution gradually decreases, while the steepness coefficient shows an increasing trend. These research findings contribute to a deeper understanding of the characteristics of lightning and provide important references for lightning prevention and disaster reduction. Full article
(This article belongs to the Special Issue Atmospheric Electricity (2nd Edition))
Show Figures

Figure 1

14 pages, 3774 KB  
Article
Locating Strong Electromagnetic Pulses Recorded by a Single Satellite with Cluster Analysis and Worldwide Lightning Location Network Observations
by Zongxiang Li, Baofeng Cao, Wenjuan Zhang, Xiaoqiang Li, Xiong Zhang, Yongli Wei, Xiao Li, Changjiao Duan and Peng Li
Remote Sens. 2024, 16(23), 4442; https://doi.org/10.3390/rs16234442 - 27 Nov 2024
Cited by 2 | Viewed by 1698
Abstract
The integration of satellite-borne and ground-based global lightning location networks offers a better perspective to study lightning processes and their evolutionary characteristics within thunderstorm clouds, thereby bolstering the predictive capabilities for severe weather phenomena. Currently, the satellite-borne network is in the preliminary testing [...] Read more.
The integration of satellite-borne and ground-based global lightning location networks offers a better perspective to study lightning processes and their evolutionary characteristics within thunderstorm clouds, thereby bolstering the predictive capabilities for severe weather phenomena. Currently, the satellite-borne network is in the preliminary testing phase with a single satellite. The geographic locations of single-satellite detection events primarily rely on synchronous information from coincident ground-based network events; this method is called synchronous locating (SCL). However, variations in detection-frequency bands and system capabilities prevent this method from accurately locating more than a mere 10% of events. To address this limitation, this paper introduces a cluster-analysis-based strategy, utilizing the observations from the Worldwide Lightning Location Network (WWLLN), termed the cluster analysis locating (CAL) method. The CAL method’s performance, influenced by the density-based spatial clustering of applications with noise (DBSCAN), the K-means, and the mean shift algorithms, is examined. Subsequently, an advanced version, mean shift denoised (MSDN)-CAL, is proposed, demonstrating marked improvements in location accuracy and reliability over the other CAL methods. The satellite-borne wideband electromagnetic pulse detector (WEMPD), orbiting at an altitude of approximately 500 km with a 97.5° inclination, captured 1061 strong electromagnetic pulses (EMPs). Among these, trans-ionospheric single pulses (TISPs) and trans-ionospheric pulse pairs (TIPPs) constituted 21.30% and 78.70%, respectively. Using the MSDN-CAL method successfully determines the geographic locations for 81.15% (861 out of 1061) of the events. This success rate represents an approximate eightfold enhancement over the SCL method. The arithmetic mean, geometric mean, and standard deviation of the two-dimensional range deviation of the locating results between the MSDN-CAL method versus the WWLLN-SCL (or the Guangdong-Hong Kong-Macao Lightning Location System (GHMLLS)-SCL) method are 51.06 (176.26) km, 16.17 (92.53) km, and 100.95 (174.79) km, respectively. Furthermore, it has been possible to estimate the occurrence altitudes for 81.92% (684 out of 835) of the TIPP events. The altitude deviations, as determined by comparing them with the GHMLLS-SCL method’s locating results, exhibit an arithmetic mean of 2.08 km, a geometric mean of 1.30 km, and a standard deviation of 2.26 km. The outcomes of this research establish a foundation for deeper investigation into the origins of various event types, their seasonal variations, and their geographical distribution patterns. Moreover, they pave the way for utilizing a single satellite to measure global surface reflectance, thus contributing valuable data for meteorological and atmospheric studies. Full article
Show Figures

Figure 1

20 pages, 8220 KB  
Article
Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment
by Hossein Amini, Ali Mehrizi-Sani and Reza Noroozian
Energies 2024, 17(17), 4405; https://doi.org/10.3390/en17174405 - 3 Sep 2024
Cited by 7 | Viewed by 2217
Abstract
Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization [...] Read more.
Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup. Full article
(This article belongs to the Section F3: Power Electronics)
Show Figures

Figure 1

16 pages, 5417 KB  
Article
Lightning Current Measurement Method Using Rogowski Coil Based on Integral Circuit with Low-Frequency Attenuation Feedback
by Yiping Xiao, Hongjian Jiao, Feng Huo and Zongtao Shen
Sensors 2024, 24(15), 4980; https://doi.org/10.3390/s24154980 - 1 Aug 2024
Cited by 7 | Viewed by 4476
Abstract
A lightning current measurement method using a Rogowski coil based on an integral circuit with low-frequency attenuation feedback was proposed to address the issue of low-frequency distortion in the measurement of lightning currents on transmission lines using Rogowski coils. Firstly, the causes of [...] Read more.
A lightning current measurement method using a Rogowski coil based on an integral circuit with low-frequency attenuation feedback was proposed to address the issue of low-frequency distortion in the measurement of lightning currents on transmission lines using Rogowski coils. Firstly, the causes of low-frequency distortion in lightning current measurements using Rogowski coils were analyzed from the perspective of frequency domains. On this basis, an integration correction optimization circuit with a low-frequency attenuation feedback network was designed to correct the low-frequency distortion. The optimized integration circuit can also reduce the impact of low-frequency noise and the DC bias of the operational amplifier (op-amp) on the integration circuit due to the high low-frequency gain. Additionally, a high-pass filtering and voltage-divided sampling circuit has been added to ensure the normal operation of the integrator and improve the measurement range of the measurement system. Then, according to the relationship between the amplitude–frequency characteristics of the measurement system and the parameters of each component, the appropriate types of components and op-amp were selected to expand the measurement bandwidth. Finally, a simulation verification was conducted, and the simulation results show that this measurement method can effectively expand the lower measurement frequency limit to 20 Hz, correct the low-frequency distortion caused by Rogowski coils measuring lightning currents on transmission lines, and accurately restore the measured lightning current waveform. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

19 pages, 42850 KB  
Article
Extraction of Factors Strongly Correlated with Lightning Activity Based on Remote Sensing Information
by Haochen Zhang, Yeqiang Deng, Yu Wang, Lei Lan, Xishan Wen, Chaoying Fang and Jun Xu
Remote Sens. 2024, 16(11), 1921; https://doi.org/10.3390/rs16111921 - 27 May 2024
Cited by 7 | Viewed by 2516
Abstract
Thunderstorms are a common natural phenomenon posing significant hazards to power systems, structures, and humans. With technological advancements, protection against lightning is gradually shifting from passive to active measures, which require the prediction of thunderstorm occurrences. Current research on lightning warning relies on [...] Read more.
Thunderstorms are a common natural phenomenon posing significant hazards to power systems, structures, and humans. With technological advancements, protection against lightning is gradually shifting from passive to active measures, which require the prediction of thunderstorm occurrences. Current research on lightning warning relies on various data sources, such as satellite data and atmospheric electric field data. However, these studies have placed greater emphasis on the process of warning implementation, overlooking the correlation between parameters used for lightning warning and lightning phenomena. This study relied on the ERA5 dataset and lightning location dataset from 117.5°E to 119.5°E longitude and 24.5°N to 25.5°N latitude during 2020–2021, utilizing Kriging interpolation to standardize the spatiotemporal precision of different parameters. After that, we conducted preliminary screening of the involved parameters based on the chi-squared test and utilized the Apriori algorithm to identify parameter intervals that were strongly associated with the occurrence of lightning. Subsequently, we extracted strong association rules oriented towards the occurrence of lightning and analyzed those rules with respect to lightning current amplitude, types, and ERA5 parameters. We found that thunderstorm phenomena are more likely to occur under specific ranges of temperature, humidity, and wind speed conditions, and we determined their parameter ranges. After that, we divided the target area into regions with different levels of lightning probability based on the strong association rules. By comparing the actual areas where lightning phenomena occurred with the areas at high risk of lightning based on ERA5 parameters, we validated the credibility of the obtained strong association rules. Full article