Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (403)

Search Parameters:
Keywords = ground source heat pumps

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 2664 KiB  
Article
Analysis of Heat Exchange Efficiency and Influencing Factors of Energy Tunnels: A Case Study of the Torino Metro in Italy
by Mei Yin, Pengcheng Liu and Zhenhuang Wu
Buildings 2025, 15(15), 2704; https://doi.org/10.3390/buildings15152704 - 31 Jul 2025
Viewed by 170
Abstract
Both ground source heat pumps (GSHPs) and energy underground structures are engineered systems that utilize shallow geothermal energy. However, due to the construction complexity and associated costs of energy tunnels, their heat exchange efficiency relative to GSHPs remains a topic worthy of in-depth [...] Read more.
Both ground source heat pumps (GSHPs) and energy underground structures are engineered systems that utilize shallow geothermal energy. However, due to the construction complexity and associated costs of energy tunnels, their heat exchange efficiency relative to GSHPs remains a topic worthy of in-depth investigation. In this study, a thermal–hydraulic (TH) coupled finite element model was developed based on a section of the Torino Metro Line in Italy to analyze the differences in and influencing factors of heat transfer performance between energy tunnels and GSHPs. The model was validated by comparing the outlet temperature curves under both winter and summer loading conditions. Based on this validated model, a parametric analysis was conducted to examine the effects of the tunnel air velocity, heat carrier fluid velocity, and fluid type. The results indicate that, under identical environmental conditions, energy tunnels exhibit higher heat exchange efficiency than conventional GSHP systems and are less sensitive to external factors such as fluid velocity. Furthermore, a comparison of different heat carrier fluids, including alcohol-based fluids, refrigerants, and water, revealed that the fluid type significantly affects thermal performance, with the refrigerant R-134a outperforming ethylene glycol and water in both heating and cooling efficiency. Full article
Show Figures

Figure 1

16 pages, 3470 KiB  
Article
Performance Analysis of Multi-Source Heat Pumps: A Regression-Based Approach to Energy Performance Estimation
by Reza Alijani and Fabrizio Leonforte
Sustainability 2025, 17(15), 6804; https://doi.org/10.3390/su17156804 - 26 Jul 2025
Viewed by 310
Abstract
The growing demand for energy-efficient heating, ventilation, and air conditioning (HVAC) systems has increased interest in multi-source heat pumps as a sustainable solution. While extensive research has been conducted on heat pump performance prediction, there is still a lack of practical tools for [...] Read more.
The growing demand for energy-efficient heating, ventilation, and air conditioning (HVAC) systems has increased interest in multi-source heat pumps as a sustainable solution. While extensive research has been conducted on heat pump performance prediction, there is still a lack of practical tools for early-stage system evaluation. This study addresses that gap by developing regression-based models to estimate the performance of various heat pump configurations, including air-source, ground-source, and dual-source systems. A simplified performance estimation model was created, capable of delivering results with accuracy levels comparable to TRNSYS simulation outputs, making it a valuable and accessible tool for system evaluation. The analysis was conducted across nine climatic zones in Italy, considering key environmental factors such as air temperature, ground temperature, and solar irradiance. Among the tested configurations, hybrid systems like Solar-Assisted Ground-Source Heat Pumps (SAGSHP) achieved the highest performance, with SCOP values up to 4.68 in Palermo and SEER values up to 5.33 in Milan. Regression analysis confirmed strong predictive accuracy (R2 = 0.80–0.95) and statistical significance (p < 0.05), emphasizing the models’ reliability across different configurations and climatic conditions. By offering easy-to-use regression formulas, this study enables engineers and policymakers to estimate heat pump performance without relying on complex simulations. Full article
(This article belongs to the Special Issue Sustainability and Energy Performance of Buildings)
Show Figures

Figure 1

25 pages, 1696 KiB  
Article
Dual-Level Electric Submersible Pump (ESP) Failure Classification: A Novel Comprehensive Classification Bridging Failure Modes and Root Cause Analysis
by Mostafa A. Sobhy, Gehad M. Hegazy and Ahmed H. El-Banbi
Energies 2025, 18(15), 3943; https://doi.org/10.3390/en18153943 - 24 Jul 2025
Viewed by 302
Abstract
Electric submersible pumps (ESPs) are critical for artificial lift operations; however, they are prone to frequent failures, often resulting in high operational costs and production downtime. Traditional ESP failure classifications are limited by lack of standardization and the conflation of failure modes with [...] Read more.
Electric submersible pumps (ESPs) are critical for artificial lift operations; however, they are prone to frequent failures, often resulting in high operational costs and production downtime. Traditional ESP failure classifications are limited by lack of standardization and the conflation of failure modes with root causes. To address these limitations, this study proposes a new two-step integrated failure modes and root cause (IFMRC) classification system. The new framework clearly distinguishes between failure modes and root causes, providing a systematic, structured approach that enhances fault diagnosis and failure analysis and can lead to better failure prevention strategies. This methodology was validated using a case study of over 4000 ESP installations. The data came from Egypt’s Western Desert, covering a decade of operational data. The sources included ESP databases, workover records, and detailed failure investigation (DIFA) reports. The failure modes were categorized into electrical, mechanical, hydraulic, chemical, and operational types, while root causes were linked to environmental, design, operational, and equipment factors. Statistical analysis, in this case study, revealed that motor short circuits, low flow conditions, and cable short circuits were the most frequent failure modes, with excessive heat, scale deposition, and electrical grounding faults being the dominant root causes. This study underscores the importance of accurate root cause failure classification, robust data acquisition, and expanded failure diagnostics to improve ESP reliability. The proposed IFMRC framework addresses limitations in conventional taxonomies and facilitates ongoing enhancement of ESP design, operation, and maintenance in complex field conditions. Full article
(This article belongs to the Section H1: Petroleum Engineering)
Show Figures

Figure 1

16 pages, 5647 KiB  
Article
Performance Degradation of Ground Source Heat Pump Systems Under Ground Temperature Disturbance: A TRNSYS-Based Simulation Study
by Yeqi Huang, Zhongchao Zhao and Mengke Sun
Energies 2025, 18(15), 3909; https://doi.org/10.3390/en18153909 - 22 Jul 2025
Viewed by 192
Abstract
Ground temperature (GT) variation significantly affects the energy performance of ground source heat pump (GSHP) systems. Both long-term thermal accumulation and short-term dynamic responses contribute to the degradation of the coefficient of performance (COP), especially under cooling-dominated conditions. This study develops a mechanism-based [...] Read more.
Ground temperature (GT) variation significantly affects the energy performance of ground source heat pump (GSHP) systems. Both long-term thermal accumulation and short-term dynamic responses contribute to the degradation of the coefficient of performance (COP), especially under cooling-dominated conditions. This study develops a mechanism-based TRNSYS simulation that integrates building loads, subsurface heat transfer, and dynamic heat pump operation. A 20-year case study in Shanghai reveals long-term performance degradation driven by thermal boundary shifts. Results show that GT increases by over 12 °C during the simulation period, accompanied by a progressive increase in ΔT by approximately 0.20 K and a consistent decline in COP. A near-linear inverse relationship is observed, with COP decreasing by approximately 0.038 for every 1 °C increase in GT. In addition, ΔT is identified as a key intermediary linking subsurface thermal disturbance to efficiency loss. A multi-scale response framework is established to capture both annual degradation and daily operational shifts along the Load–GT–ΔT–COP pathway. This study provides a quantitative explanation of the thermal degradation process and offers theoretical guidance for performance forecasting, operational threshold design, and thermal regulation in GSHP systems. Full article
(This article belongs to the Section B: Energy and Environment)
Show Figures

Figure 1

32 pages, 2768 KiB  
Article
A Comprehensive Simplified Algorithm for Heat Transfer Modeling of Medium-Deep Borehole Heat Exchangers Considering Soil Stratification and Geothermal Gradient
by Boyu Li, Fei Lei and Zibo Shen
Energies 2025, 18(14), 3716; https://doi.org/10.3390/en18143716 - 14 Jul 2025
Viewed by 234
Abstract
Medium-deep borehole heat exchanger (BHE) systems represent an emerging form of ground source heat pump technology. Their heat transfer process is significantly influenced by geothermal gradient and soil stratification, typically simulated using segmented finite line source (SFLS) models. However, this approach involves computationally [...] Read more.
Medium-deep borehole heat exchanger (BHE) systems represent an emerging form of ground source heat pump technology. Their heat transfer process is significantly influenced by geothermal gradient and soil stratification, typically simulated using segmented finite line source (SFLS) models. However, this approach involves computationally intensive procedures that hinder practical engineering implementation. Building upon an SFLS model adapted for complex geological conditions, this study proposes a comprehensive simplified algorithm: (1) For soil stratification: A geothermally-weighted thermal conductivity method converts layered heterogeneous media into an equivalent homogeneous medium; (2) For geothermal gradient: A temperature correction method establishes fluid temperatures under geothermal gradient by superimposing correction terms onto uniform-temperature model results (g-function model). Validated through two engineering case studies, this integrated algorithm provides a straightforward technical tool for heat transfer calculations in BHE systems. Full article
Show Figures

Figure 1

22 pages, 3505 KiB  
Article
Coupled Study on the Building Load Dynamics and Thermal Response of Ground Sources in Shallow Geothermal Heat Pump Systems Under Severe Cold Climate Conditions
by Jianlin Li, Xupeng Qi, Xiaoli Li, Huijie Huang and Jian Gao
Modelling 2025, 6(3), 63; https://doi.org/10.3390/modelling6030063 - 7 Jul 2025
Viewed by 214
Abstract
To address thermal imbalance and ground temperature degradation in shallow geothermal heat pump (GSHP) systems in severely cold climates, this study analyzes a typical logistics building using an hourly dynamic load model. Multiyear simulations were conducted to investigate the coupling between building load [...] Read more.
To address thermal imbalance and ground temperature degradation in shallow geothermal heat pump (GSHP) systems in severely cold climates, this study analyzes a typical logistics building using an hourly dynamic load model. Multiyear simulations were conducted to investigate the coupling between building load variation and soil thermal response. The results indicate that with a cumulative heating load of 14.681 million kWh and cooling load of 6.3948 million kWh, annual heat extraction significantly exceeds heat rejection, causing ground temperature to decline by about 1 °C per year. Over five and ten years, the cumulative drops reached 2.65 °C and 4.71 °C, respectively, leading to a noticeable reduction in borehole heat exchanger performance and system COP. The study quantitatively evaluates ground temperature and heat exchange degradation, highlighting the key role of load imbalance. To mitigate long-term thermal deterioration, strategies such as load optimization, summer heat reinjection, and operational adjustments are proposed. The findings offer guidance for the design and sustainable operation of GSHP systems in cold regions. Full article
Show Figures

Figure 1

30 pages, 2104 KiB  
Article
Meeting 2030 Targets: Heat Pump Installation Scenarios in Italy
by Giovanni Murano, Francesca Caffari, Nicolandrea Calabrese and Marco Dall’Ombra
Sustainability 2025, 17(13), 5938; https://doi.org/10.3390/su17135938 - 27 Jun 2025
Viewed by 669
Abstract
The study examines the role of heat pumps (HPs) in achieving the targets set by the Italian National Integrated Energy and Climate Plan (PNIEC) for 2030, using official data and European-recognized calculation methodologies to quantify the renewable energy produced. Starting from the current [...] Read more.
The study examines the role of heat pumps (HPs) in achieving the targets set by the Italian National Integrated Energy and Climate Plan (PNIEC) for 2030, using official data and European-recognized calculation methodologies to quantify the renewable energy produced. Starting from the current stock analysis—21 million HPs installed in 2022, providing 39 GWth of thermal capacity—the research outlines potential growth scenarios based on installation trends from the past three years: Scenario A assumes 2.5 million HPs/year, (b) 2.2 million/year, and (c) 1.6 million/year. Only Scenario A, the most ambitious, achieves full compliance with 2030 targets by ensuring over 4723 ktoe of renewable energy produced. An additional Scenario D is analyzed, based on the lowest annual installed capacity observed in the past three years but with a modified technology mix emphasizing air-to-water (A/W) and ground-source water-to-water (W/W) HPs. This scenario still achieves the 2030 goals, reaching 66.04 GWth and 4859 ktoe of renewable energy. The results confirm that technology choices will be strategic to meet the targets. The study also highlights the importance of stable incentive policies, proper development of the industrial supply chain, and a plan for the technological upgrading of the existing systems stock. Full article
(This article belongs to the Special Issue Sustainability and Energy Performance of Buildings)
Show Figures

Figure 1

25 pages, 1652 KiB  
Review
Review of the Role of Heat Pumps in Decarbonization of the Building Sector
by Agnieszka Żelazna and Artur Pawłowski
Energies 2025, 18(13), 3255; https://doi.org/10.3390/en18133255 - 21 Jun 2025
Viewed by 602
Abstract
The transition to low-carbon heating systems is fundamental to achieving climate neutrality, particularly within the building sector, which accounts for a significant share of global greenhouse gas emissions. Among various technologies, heat pumps have emerged as a leading solution due to their high [...] Read more.
The transition to low-carbon heating systems is fundamental to achieving climate neutrality, particularly within the building sector, which accounts for a significant share of global greenhouse gas emissions. Among various technologies, heat pumps have emerged as a leading solution due to their high energy efficiency and potential to significantly reduce CO2 emissions, especially when powered by renewable electricity. This systematic review synthesizes findings from the recent literature, including peer-reviewed studies and industry reports, to evaluate the technical performance, environmental impact, and deployment potential of air source, ground source, and water source heat pumps. This review also investigates life cycle greenhouse gas emissions, the influence of geographical energy mix diversity, and the integration of heat pumps within hybrid and district heating systems. Results indicate that hybrid HP systems achieve the lowest specific GHG emissions (0.108 kgCO2eq/kWh of heat delivered on average), followed by WSHPs (0.018 to 0.216 kgCO2eq/kWh), GSHPs (0.050–0.211 kgCO2eq/kWh), and ASHPs (0.083–0.216 kgCO2eq/kWh). HP systems show a potential GHG emission reduction of up to 90%, depending on the kind of technology and energy mix. Despite higher investment costs, the lower environmental footprint of GSHPs and WSHPs makes them attractive options for decarbonizing the building sector due to better performance resulting from more stable thermal input and higher SCOP. The integration of heat pumps with thermal storage, renewable energy, and smart control technologies further enhances their efficiency and climate benefits, regardless of the challenges facing their market potential. This review concludes that heat pumps, particularly in hybrid configurations, are a cornerstone technology for sustainable building heat supply and energy transition. Full article
(This article belongs to the Section A: Sustainable Energy)
Show Figures

Graphical abstract

17 pages, 1848 KiB  
Article
Overcoming Uncertainties Associated with Local Thermal Response Functions in Vertical Ground Heat Exchangers
by Alejandro J. Extremera-Jiménez, Pedro J. Casanova-Peláez, Charles Yousif and Fernando Cruz-Peragón
Sustainability 2025, 17(12), 5509; https://doi.org/10.3390/su17125509 - 15 Jun 2025
Viewed by 939
Abstract
The short-term performance of ground heat exchangers (GHEs) is crucial for the optimal design of ground-source heat pumps (GSHPs), enhancing their contribution to sustainable energy solutions. Local short-time thermal response functions, or short-time g-functions (STGFs) derived from thermal response tests (TRTs), are of [...] Read more.
The short-term performance of ground heat exchangers (GHEs) is crucial for the optimal design of ground-source heat pumps (GSHPs), enhancing their contribution to sustainable energy solutions. Local short-time thermal response functions, or short-time g-functions (STGFs) derived from thermal response tests (TRTs), are of great interest for predicting the heat exchange due to their fast and simple applicability. The aim of this work is to perform a sensitivity analysis to assess the impact of thermal parameter variability and TRT operating conditions on the accuracy of the average fluid temperature (Tf) predictions obtained through a local STGF. First, the uncertainties associated with the borehole thermal resistance (Rb), transmitted from the soil volumetric heat capacity (CS) or some models dependent on GHE characteristics, such as the Zeng model, were found to have a low impact in Tf resulting in long-term deviations of ±0.2 K. Second, several TRTs were carried out on the same borehole, changing input parameters such as the volumetric flow rate and heat injection rate, in order to obtain their corresponding STGF. Validation results showed that each Tf profile consistently aligned well with experimental data when applying intermittent heat rate pulses (being the most unfavorable scenario), implying deviations of ±0.2 K, despite the variabilities in soil conductivity (λS), soil volumetric heat capacity (CS), and borehole thermal resistance (Rb). Full article
(This article belongs to the Special Issue Ground Source Heat Pump and Renewable Energy Hybridization)
Show Figures

Figure 1

31 pages, 4590 KiB  
Article
A Semi-Analytical Dynamic Model for Ground Source Heat Pump Systems: Addressing Medium- to Long-Term Performance Under Ground Temperature Variations
by Mohammad Mahmoudi Majdabadi and Seama Koohi-Fayegh
Sustainability 2025, 17(12), 5391; https://doi.org/10.3390/su17125391 - 11 Jun 2025
Viewed by 679
Abstract
As the demand for sustainable heating, ventilation, and air conditioning (HVAC) solutions rises, ground source heat pumps (GSHPs) offer high efficiency but are sensitive to subsurface thermal dynamics. The overall objective of this study is to evaluate the impact of ground temperature variations [...] Read more.
As the demand for sustainable heating, ventilation, and air conditioning (HVAC) solutions rises, ground source heat pumps (GSHPs) offer high efficiency but are sensitive to subsurface thermal dynamics. The overall objective of this study is to evaluate the impact of ground temperature variations on GSHP performance by proposing a semi-analytical dynamic model capable of simulating medium- to long-term heat pump operations. The proposed model accounts for the interactions between the ground heat exchanger (GHE) and the heat pump. A case study using the proposed model demonstrates how ground temperature variations from external factors affect the coefficient of performance (COP) and the heating and cooling capacity of GSHP systems. For ±5 °C ground shifts, the heating capacity falls below peak demand if the subsurface temperature drops by more than 2 °C, requiring supplemental heating. Peak cooling and capacity vary by less than 1% and 3% for every unit of ground temperature change (°C), respectively. These results quantify both the resilience and limits of GSHP sustainability under realistic thermal disturbances. Full article
(This article belongs to the Special Issue Ground Source Heat Pump and Renewable Energy Hybridization)
Show Figures

Figure 1

27 pages, 10560 KiB  
Article
Ground Heat Exchangers from Artificial Ground-Freezing Probes for Tunnel Excavations
by Fawad Ahmed, Nicola Massarotti, Alessandro Mauro and Gennaro Normino
Energies 2025, 18(11), 2965; https://doi.org/10.3390/en18112965 - 4 Jun 2025
Viewed by 459
Abstract
Ground-source heat pumps (GSHPs), despite their high efficiencies, are still not as cost-effective as air-source heat pumps, especially in urban environments, due to the necessity of drilling/excavation. Integrating GSHPs into existing geo-structures, such as underground tunnels, can play a vital role in reducing [...] Read more.
Ground-source heat pumps (GSHPs), despite their high efficiencies, are still not as cost-effective as air-source heat pumps, especially in urban environments, due to the necessity of drilling/excavation. Integrating GSHPs into existing geo-structures, such as underground tunnels, can play a vital role in reducing the overall costs of GSHP systems and promoting their use in cities. Tunnels can be realized through artificial ground freezing (AGF) by using probes for circulating the freezing fluid, which are left in the ground once the tunnel is completed. The novelty of the present work lies in the proposal of a sustainable reuse of AGF probes as ground heat exchangers (GHEs). The idea of converting AGF probes is both sustainable and cost-effective for GSHPs, as it can reduce installation costs by eliminating the drilling/excavation process. A test was performed for the first time in the Piazza Municipio metro station in Naples, Southern Italy, where several AGF probes, initially used for the construction of two tunnels, have then been converted into GHEs. The probes have been connected to a testing device called the energy box. The experiments included testing the heat transfer in the recovered AGF probes through cooling and heating operations. This work presents a numerical simulation of a test that has been validated against experimental results. Full article
Show Figures

Figure 1

30 pages, 10870 KiB  
Article
Research on Configuration Optimization and Control Methods for Mid-Deep Geothermal Heat Pumps Coupled with Air-Source Heat Pump Systems for Space Heating in Residential Buildings
by Yanhui Wang, Jiewen Deng, Yangyang Su, Chenwei Peng, Minghui Ma, Yin Chen, Lei Fan, Min Chen, Qingpeng Wei and Hui Zhang
Buildings 2025, 15(11), 1938; https://doi.org/10.3390/buildings15111938 - 3 Jun 2025
Cited by 1 | Viewed by 306
Abstract
Mid-deep geothermal heat pump systems (MD-GHPs) feature high energy efficiency and low energy consumption, yet their promotion is restricted by high initial investment. While the initial investment of air-source heat pumps (ASHPs) is obviously lower, it also has a larger energy consumption. To [...] Read more.
Mid-deep geothermal heat pump systems (MD-GHPs) feature high energy efficiency and low energy consumption, yet their promotion is restricted by high initial investment. While the initial investment of air-source heat pumps (ASHPs) is obviously lower, it also has a larger energy consumption. To address the complementary strengths and weaknesses of single-source heat pump systems, this paper puts forward an integrated system combining MD-GHPs and ASHPs, and the series mode was determined as the optimal integration approach for the hybrid system through comparative analysis. Simulation analysis was conducted to explore the adaptability of series mode, and numbers of mid-deep ground heat exchangers in nine cities across various climate regions were studied. The MD-GHP system is suitable for space heating in Xining and Xi’an, while ASHPs are suitable for space heating in Nanjing and Hangzhou. For intermediate resource areas like Urumqi and Tsingdao, the series mode achieves the best economic benefits during the 24th year of operation. Full article
Show Figures

Figure 1

22 pages, 3538 KiB  
Article
Optimisation of Dynamic Operation Strategy for a Regional Multi-Energy System to Reduce Energy Congestion
by Yubang Hu, Qingjie Chen, Jiahui Fan, Shanshan Hu and Yingning Hu
Energies 2025, 18(11), 2857; https://doi.org/10.3390/en18112857 - 30 May 2025
Viewed by 426
Abstract
Focusing on the power consumption of a regional multi-energy system with the characteristics of energy congestion in students’ dormitory buildings in the hot summer and warm winter regions of southern China, a practical regional multi-energy system consisting of three subsystems, namely an integrated [...] Read more.
Focusing on the power consumption of a regional multi-energy system with the characteristics of energy congestion in students’ dormitory buildings in the hot summer and warm winter regions of southern China, a practical regional multi-energy system consisting of three subsystems, namely an integrated screw chiller (ISC), a screw ground-source heat pump (SGSHP), and an air-source heat pump (ASHP), was optimised by the operation control strategy. The system’s power consumption and cooling/heating load characteristics during operation were analysed, and changes in the terminal air-conditioning load were simulated. Based on the dynamic cooling and heating load of the building, a two-stage loading strategy was proposed for optimising the system operation. Taking the load demand matching requirement of the system output and the terminal load demand as constraints, a simulation model of the system was developed using TRNSYS 16 software, and the changes in power consumption and the cooling/heating capacity before and after optimisation were analysed. The results show that the optimised system reduced annual power consumption by approximately 19% and increased condensation heat recovery by about 2.3%. The optimised operation control strategy was aligned well with the terminal cooling and heating demands. Full article
Show Figures

Figure 1

29 pages, 2457 KiB  
Article
Energy and Exergy Analysis of a Photovoltaic-Thermal Geothermal Heat Pump Coupled with Radiant Ceiling and Fresh Air System
by Yaolin Lin, Zhenyan Bu, Wei Yang, Melissa Chan, Lin Tian and Mingqi Dai
Energies 2025, 18(11), 2715; https://doi.org/10.3390/en18112715 - 23 May 2025
Viewed by 382
Abstract
This paper presents energy and exergy studies on a photovoltaic-thermal solar-assisted geothermal heat pump coupled with a radiant ceiling system. The system utilizes renewable solar and geothermal energy. It has an independent fresh air unit that provides clean air to the space. The [...] Read more.
This paper presents energy and exergy studies on a photovoltaic-thermal solar-assisted geothermal heat pump coupled with a radiant ceiling system. The system utilizes renewable solar and geothermal energy. It has an independent fresh air unit that provides clean air to the space. The computer model of the system was developed under the TRNSYST environment and validated with experimental results from open literature. Distribution of the energy consumption and exergy loss of the system were analyzed. It was found that the heat pump unit consumes the largest amount of energy while the transmission and distribution system has the highest exergy loss. Under optimized operating conditions, i.e., both demand side circulation flow and source side circulation flow are maintained at 65% of the design flow rate (design loop water temperature difference of 7.0 °C), the average exergy efficiency of the whole system was found to be 37.56%, which achieves an accumulative exergy loss reduction of 16.5% compared with 100% design flow rate condition during cooling season. The optimal bearing load ratio of the ground source heat pump vs. photovoltaic-thermal system in the heating season was found to be 67%. Full article
(This article belongs to the Section G: Energy and Buildings)
Show Figures

Figure 1

23 pages, 5215 KiB  
Article
Experimental Evaluation of Hybrid Renewable and Thermal Energy Storage Systems for a Net-Zero Energy Greenhouse: A Case Study of Yeoju-Si
by Misbaudeen Aderemi Adesanya, Anis Rabiu, Qazeem Opeyemi Ogunlowo, Min-Hwi Kim, Timothy Denen Akpenpuun, Wook-Ho Na, Kuljeet Singh Grewal and Hyun-Woo Lee
Energies 2025, 18(10), 2635; https://doi.org/10.3390/en18102635 - 20 May 2025
Viewed by 582
Abstract
The implementation of renewable energy systems (RESs) in the agricultural sector has significant potential to mitigate the negative effects of fossil fuel-based products on the global climate, reduce operational costs, and enhance crop production. However, the intermittent nature of RESs poses a major [...] Read more.
The implementation of renewable energy systems (RESs) in the agricultural sector has significant potential to mitigate the negative effects of fossil fuel-based products on the global climate, reduce operational costs, and enhance crop production. However, the intermittent nature of RESs poses a major challenge to realizing these benefits. To address this, thermal energy storage (TES) and hybrid heat pump (HHP) systems are integrated with RESs to balance the mismatch between thermal energy production and demand. In pursuit of clean energy solutions in the agricultural sector, a 3942 m2 greenhouse in Yeoju-si, South Korea, is equipped with 231 solar thermal (ST) collectors, 117 photovoltaic thermal (PVT) collectors, four HHPs, two ground-source heat pumps (GSHPs), a 28,500 m3 borehole TES (BTES) unit, a 1040 m3 tank TES (TTES) unit, and three short-term TES units with capacities of 150 m3, 30 m3, and 30 m3. This study evaluates the long-term performance of the integrated hybrid renewable energy and thermal energy storage systems (HRETESSs) in meeting the greenhouse’s heating and cooling demands. Results indicate that the annual system performance efficiencies range from 25.3% to 68.5% for ST collectors and 31.9% to 72.2% for PVT collectors. The coefficient of performance (COP) during the heating season is 3.3 for GSHPs, 2.5 for HHPs using BTES as a source, and 3.6 for HHPs using TTES as a source. During the cooling season, the COP ranges from 5.3 to 5.7 for GSHPs and 1.84 to 2.83 for ASHPs. Notably, the HRETESS supplied 3.4% of its total heating energy directly from solar energy, 89.3% indirectly via heat pump utilization, and 7.3% is provided by auxiliary heating. This study provides valuable insights into the integration of HRETESSs to maximize greenhouse energy efficiency and supports the development of sustainable agricultural energy solutions, contributing to reduced greenhouse gas emissions and operational costs. Full article
(This article belongs to the Section B: Energy and Environment)
Show Figures

Figure 1

Back to TopTop