Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (120)

Search Parameters:
Keywords = disposable electrochemical sensor

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 3024 KiB  
Article
Rapid Microwave-Assisted Synthesis of CuSe Nanoparticles for High-Sensitivity Serotonin Biosensing in Serum
by Sankar Sekar, Ramalingam Manikandan, Shiva Kumar Arumugasamy, Saravanan Sekar, Youngmin Lee, Seung-Cheol Chang and Sejoon Lee
Chemosensors 2025, 13(7), 264; https://doi.org/10.3390/chemosensors13070264 - 21 Jul 2025
Viewed by 398
Abstract
In this study, a simple and effective approach was developed for the quantitative detection of serotonin. Hexagonal copper selenide nanostructures (CuSe) were employed to modify a disposable screen-printed carbon electrode (SPCE), and their ability to electrochemically detect serotonin in serum samples was investigated. [...] Read more.
In this study, a simple and effective approach was developed for the quantitative detection of serotonin. Hexagonal copper selenide nanostructures (CuSe) were employed to modify a disposable screen-printed carbon electrode (SPCE), and their ability to electrochemically detect serotonin in serum samples was investigated. The fabricated CuSe nanostructures exhibited an interconnected, cluster-like morphology composed of irregularly shaped particles with a distinct hexagonal crystal structure. The electrochemical results revealed that the CuSe/SPCE sensor showed better electrochemical activity and good analytical sensing performance towards serotonin detection. The sensor exhibited a linear response in the concentration range of 10 to 1000 nM, with an excellent correlation coefficient (R2 = 0.9998) and a low detection limit of 3 nM. Furthermore, the CuSe/SPCE showed better selectivity, impressive sensitivity (12.45 µM/µA cm−2), and good reproducibility toward serotonin detection, making it a promising electrochemical biosensor for serotonin detection in various real biological samples. Full article
(This article belongs to the Special Issue Electrochemical Sensing in Medical Diagnosis)
Show Figures

Figure 1

14 pages, 1587 KiB  
Article
Electrochemical Disposable Printed Aptasensor for Sensitive Ciprofloxacin Monitoring in Milk Samples
by Daniela Nunes da Silva, Thaís Cristina de Oliveira Cândido and Arnaldo César Pereira
Chemosensors 2025, 13(7), 235; https://doi.org/10.3390/chemosensors13070235 - 28 Jun 2025
Viewed by 432
Abstract
An electrochemical aptasensor was developed for the rapid and sensitive detection of ciprofloxacin (CPX) in milk samples. The device was fabricated on a polyethylene terephthalate (PET) substrate using a screen-printing technique with carbon-based conductive ink. Gold nanoparticles (AuNPs) were incorporated to enhance aptamer [...] Read more.
An electrochemical aptasensor was developed for the rapid and sensitive detection of ciprofloxacin (CPX) in milk samples. The device was fabricated on a polyethylene terephthalate (PET) substrate using a screen-printing technique with carbon-based conductive ink. Gold nanoparticles (AuNPs) were incorporated to enhance aptamer immobilization and facilitate electron transfer at the electrode surface. The sensor’s analytical performance was optimized by adjusting key parameters, including AuNP volume, DNA aptamer concentration, and incubation times for both the aptamer and the blocking agent (6-mercapto-1-hexanol, MCH). Differential pulse voltammetry (DPV) measurements demonstrated a linear response ranging from 10 to 50 nmol L−1 and a low detection limit of 3.0 nmol L−1. When applied to real milk samples, the method achieved high recovery rates (101.4–106.7%) with a relative standard deviation below 3.1%, confirming its robustness. This disposable and cost-effective aptasensor represents a promising tool for food safety monitoring, with potential for adaptation to detect other pharmaceutical residues in dairy products. Full article
Show Figures

Figure 1

15 pages, 2152 KiB  
Article
Ultrasensitive Analysis of BRCA-1 Based on Gold Nanoparticles and Molybdenum Disulfide Electrochemical Immunosensor with Enhanced Signal Amplification
by Derya Bal Altuntaş
Biosensors 2025, 15(5), 330; https://doi.org/10.3390/bios15050330 - 21 May 2025
Viewed by 650
Abstract
The BRCA-1 protein, recognized for its diagnostic relevance in a wide spectrum of malignancies, has been the focus of extensive investigation. In this study, an electrochemical immunosensor specifically designed for BRCA-1 detection was fabricated. The sensing platform utilizes disposable pencil graphite electrodes modified [...] Read more.
The BRCA-1 protein, recognized for its diagnostic relevance in a wide spectrum of malignancies, has been the focus of extensive investigation. In this study, an electrochemical immunosensor specifically designed for BRCA-1 detection was fabricated. The sensing platform utilizes disposable pencil graphite electrodes modified with a nanocomposite composed of gold nanoparticles (AuNPs), molybdenum disulfide (MoS2), and chitosan (CS). This multifunctional nanostructure significantly promotes electron transfer efficiency and supports the effective immobilization of antibodies. The constructed immunosensor exhibited excellent analytical performance, with a linear detection range between 0.05 and 20 ng/mL for BRCA-1 and a notably low limit of detection at 0.04 ng/mL. The device maintained a relative standard deviation of 3.59% (n = 3), indicating strong reproducibility. In addition, a high recovery rate of 98 ± 3% was achieved in spiked serum samples, even in the presence of common electroactive interferents such as dopamine and ascorbic acid. These findings highlight the sensor’s promising applicability for the clinical detection of BRCA-1 and potentially other cancer-related biomarkers. Full article
(This article belongs to the Section Biosensor Materials)
Show Figures

Figure 1

44 pages, 16366 KiB  
Review
Recent Advances in Paper-Based Electronics: Emphasis on Field-Effect Transistors and Sensors
by Dimitris Barmpakos, Apostolos Apostolakis, Fadi Jaber, Konstantinos Aidinis and Grigoris Kaltsas
Biosensors 2025, 15(5), 324; https://doi.org/10.3390/bios15050324 - 19 May 2025
Viewed by 1355
Abstract
Paper-based electronics have emerged as a sustainable, low-cost, and flexible alternative to traditional substrates for electronics, particularly for disposable and wearable applications. This review outlines recent developments in paper-based devices, focusing on sensors and paper-based field-effect transistors (PFETs). Key fabrication techniques such as [...] Read more.
Paper-based electronics have emerged as a sustainable, low-cost, and flexible alternative to traditional substrates for electronics, particularly for disposable and wearable applications. This review outlines recent developments in paper-based devices, focusing on sensors and paper-based field-effect transistors (PFETs). Key fabrication techniques such as laser-induced graphene, inkjet printing, and screen printing have enabled the creation of highly sensitive and selective devices on various paper substrates. Material innovations, especially the integration of graphene, carbon-based materials, conductive polymers, and other novel micro- and nano-enabled materials, have significantly enhanced device performance. This review discusses modern applications of paper-based electronics, with a particular emphasis on biosensors, electrochemical and physical sensors, and PFETs designed for flexibility, low power, and high sensitivity. Advances in PFET architectures have further enabled the development of logic gates and memory systems on paper, highlighting the potential for fully integrated circuits. Despite challenges in durability and performance consistency, the field is rapidly evolving, driven by the demand for green electronics and the need for decentralized, point-of-care diagnostic tools. This paper also identifies detection strategies used in paper-based sensors, reviews limitations in the current fabrication methods, and outlines opportunities for the scalable production of multifunctional paper-based systems. This review addresses a critical gap in the literature by linking device-level innovation with real-world sensor applications on paper substrates. Full article
(This article belongs to the Special Issue Biosensing and Diagnosis—2nd Edition)
Show Figures

Figure 1

15 pages, 4484 KiB  
Article
A Highly Sensitive Electrochemical Immunosensor for Cortisol Detection
by Pritu Parna Sarkar, Ali Ashraf, Ahmed Hasnain Jalal, Fahmida Alam and Nazmul Islam
Biosensors 2025, 15(5), 321; https://doi.org/10.3390/bios15050321 - 17 May 2025
Viewed by 1139
Abstract
In this research, an interdigitated gear-shaped working electrode is presented for cortisol sensing. Overall, the sensor was designed in a three-electrode system and was fabricated using direct laser scribing. A synthesized conductive ink based on graphene and polyaniline was further employed to enhance [...] Read more.
In this research, an interdigitated gear-shaped working electrode is presented for cortisol sensing. Overall, the sensor was designed in a three-electrode system and was fabricated using direct laser scribing. A synthesized conductive ink based on graphene and polyaniline was further employed to enhance the electrochemical performance of the sensor. Scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy were employed for physicochemical characterization of the laser-induced graphene (LIG) sensor. Cortisol, a biomarker essential in detecting stress, was detected both in phosphate-buffered saline (PBS, pH = 7.4) and human serum within a linear range of 100 ng/mL to 100 µg/mL. Ferri/ferrocyanide was employed as the redox probe to detect cortisol in PBS. The electrochemical performance of the developed sensor was assessed via differential pulse voltammetry (DPV), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and chronoamperometry. The electrochemical performance demonstrates high sensitivity and selectivity alongside strong repeatability (relative standard deviation (RSD) = 3.8%, n = 4) and reproducibility (RSD = 5.85%, n = 5). Overall, these results highlight the sensor’s reliability, high sensitivity, and repeatability and reproducibility in the detection of cortisol. The sensor successfully detected cortisol in the complex medium of human serum and effectively distinguished it in a ternary mixture containing cortisol and dopamine. Also, the use of direct laser writing on Kapton film makes the approach cost-effective and thus disposable, making it suitable for chronic stress diagnostics and neurological research applications. Full article
(This article belongs to the Special Issue Innovative Biosensing Technologies for Sustainable Healthcare)
Show Figures

Figure 1

17 pages, 3386 KiB  
Article
MoS2/MWCNT Nanostructure: Enhanced Performance of Screen-Printed Carbon Electrode for Voltammetric Determination of 4-Nitrophenol in Water Samples
by Hadi Beitollahi and Somayeh Tajik
Micromachines 2025, 16(4), 366; https://doi.org/10.3390/mi16040366 - 23 Mar 2025
Cited by 2 | Viewed by 514
Abstract
In the present work, we designed a straightforward and disposable voltammetric sensor utilizing a molybdenum disulfide/multi-walled carbon nanotube nanostructure-modified screen-printed carbon electrode (MoS2/MWCNTs/SPCE) for 4-nitrophenol (4-NP) determination. The successful synthesis of the MoS2/MWCNT nanostructure was characterized using Fourier transform [...] Read more.
In the present work, we designed a straightforward and disposable voltammetric sensor utilizing a molybdenum disulfide/multi-walled carbon nanotube nanostructure-modified screen-printed carbon electrode (MoS2/MWCNTs/SPCE) for 4-nitrophenol (4-NP) determination. The successful synthesis of the MoS2/MWCNT nanostructure was characterized using Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EXD) mapping. The electrochemical behavior of 4-NP at the MoS2/MWCNTs/SPCE was examined using differential pulse voltammetry (DPV), cyclic voltammetry (CV), and chronoamperometry techniques. The MoS2/MWCNTs/SPCE exhibited outstanding electro-catalytic activity for the voltammetric detection of 4-NP. Under optimized conditions, the reduction peak current showed a linear dependence with the concentration of 4-NP in the range of 0.05 to 800.0 µM, and a detection limit (LOD) of 0.01 µM was determined. In addition, the MoS2/MWCNTs/SPCE sensor has advantages including repeatability, reproducibility, stability, inexpensiveness, and practical application. The MoS2/MWCNTs/SPCE-based sensor was also utilized for the determination of 4-NP in real water specimens. Full article
Show Figures

Figure 1

13 pages, 1915 KiB  
Article
Gold Nanoparticle-Enhanced Graphene Immunosensor for Rapid Detection of Gardnerella vaginalis in Clinical Diagnostics
by Wioleta Lewandowska, Marta Sosnowska, Tomasz Łęga, Kasjan Szemiako, Sabina Żołędowska, Dawid Nidzworski and Beata Gromadzka
Chemosensors 2025, 13(3), 111; https://doi.org/10.3390/chemosensors13030111 - 19 Mar 2025
Cited by 1 | Viewed by 748
Abstract
The global market increasingly demands alternative rapid diagnostic tools, such as disposable biosensors, to meet the growing need for point-of-care clinical testing of infectious diseases. Bacterial vaginosis (BV), a common infection caused by Gardnerella vaginalis, requires efficient and accurate detection methods to [...] Read more.
The global market increasingly demands alternative rapid diagnostic tools, such as disposable biosensors, to meet the growing need for point-of-care clinical testing of infectious diseases. Bacterial vaginosis (BV), a common infection caused by Gardnerella vaginalis, requires efficient and accurate detection methods to improve patient outcomes and prevent complications. However, existing diagnostic approaches often lack sensitivity, specificity, or rapid response times, highlighting the need for innovative biosensing solutions. In response to this challenge, we developed a peptide-based electrochemical biosensor for the specific detection of Gardnerella vaginalis. The sensor was designed to achieve high sensitivity, selectivity, and stability, with detection performed through electrochemical techniques. Cyclic voltammetry (CV) was employed to monitor electron transfer kinetics at the electrode surface, while electrochemical impedance spectroscopy (EIS) provided insights into changes in resistance and capacitance during peptide binding. The sensor fabrication involved covalently bonding anti-Gardnerella vaginalis peptides to a gold nanoparticle (AuNP)-modified graphene electrode, significantly enhancing bioreceptor immobilization stability and increasing the surface area for target binding interactions. The incorporation of AuNPs improved signal amplification due to their high surface-to-volume ratio and excellent conductivity, leading to enhanced sensor performance. The biosensor demonstrated a low detection limit (LOD) of 0.02305 μg/mL, with a rapid response time of 5 min across various concentrations of the target Gardnerella vaginalis antigen. The results confirmed specific and selective binding to the pathogen marker, with minimal interference from non-target species, ensuring high accuracy. The combination of graphene, AuNPs, and peptide bioreceptors resulted in robust signal enhancement, making this biosensor a promising tool for fast and reliable point-of-care diagnostics in clinical settings. Full article
Show Figures

Figure 1

40 pages, 4519 KiB  
Review
Advances in Monitoring Crop and Soil Nutrient Status: Proximal and Remote Sensing Techniques
by Pedro Tomas Bulacio Fischer, Alessandro Carella, Roberto Massenti, Raudhatul Fadhilah and Riccardo Lo Bianco
Horticulturae 2025, 11(2), 182; https://doi.org/10.3390/horticulturae11020182 - 8 Feb 2025
Cited by 1 | Viewed by 1567
Abstract
Soil and water pollution caused by excessive use of fertilizers and resource scarcity are critical issues in modern horticulture. Although laboratory tests are reliable, they take time and use chemical reagents that must be disposed of and complex protocols. Monitoring plant nutrient status [...] Read more.
Soil and water pollution caused by excessive use of fertilizers and resource scarcity are critical issues in modern horticulture. Although laboratory tests are reliable, they take time and use chemical reagents that must be disposed of and complex protocols. Monitoring plant nutrient status through technologies that allow continuous and rapid assessment is crucial for precise resource management. Several proximal and remote sensors that use different physico-chemical principles to monitor plant nutrient status are available nowadays. However, these technologies still have important operative and structural limitations that must be overcome. The aim of this review is to summarize the current status and latest developments in proximal and remote sensors capable of monitoring plant and soil nutrients, focusing on sensor types, principles, applications, and their strengths and weaknesses. Electrochemical proximal sensors allow continuous monitoring of nutrients in the plant sap or in the soil solution but work on a single spot basis. Instruments based on optical sensors allow immediate measurements and quick analysis, but do not work on a continuous basis. On the other hand, remote sensors, such as drone-mounted cameras and satellite systems, are based on large-area imaging and can be used to estimate crop nutrient status by processing images at different wavelengths. Finally, combining proximal and remote techniques may be needed to achieve very accurate monitoring of plant and nutrient status. Full article
(This article belongs to the Special Issue Irrigation and Fertilization Management in Horticultural Production)
Show Figures

Figure 1

13 pages, 5084 KiB  
Article
Electrochemical Glucose Sensor Based on Dual Redox Mediators
by Changyun Quan, Yue Zhang, Yuanyuan Liu, Liping Wen, Haixia Yang, Xueqin Huang, Minghui Yang and Binjie Xu
Biosensors 2025, 15(1), 9; https://doi.org/10.3390/bios15010009 - 27 Dec 2024
Cited by 3 | Viewed by 2678
Abstract
Electrochemical glucose sensor holds significant promise for the monitoring of blood glucose levels in diabetic patients. In this study, we proposed a novel electrochemical glucose sensor based on 1,10-Phenanthroline-5,6-dione (PD)/Ru(III) as a dual redox mediator. The synergistic effect of PD and Ru(III) was [...] Read more.
Electrochemical glucose sensor holds significant promise for the monitoring of blood glucose levels in diabetic patients. In this study, we proposed a novel electrochemical glucose sensor based on 1,10-Phenanthroline-5,6-dione (PD)/Ru(III) as a dual redox mediator. The synergistic effect of PD and Ru(III) was utilized to efficiently facilitate the electron transfer between the enzyme-active center and the electrode. Then, a commercial disposable electrochemical glucose sensor was constructed based on screen-printing electrodes. Experimental results indicated the synergy between PD and Ru(III) provided a promising electron transfer environment for a glucose dehydrogenase (GDH)-catalyzed glucose reaction. The sensor exhibits a linear glucose response range from 0.01 to 38.6 mmol/L, with a limit of detection (LOD) as low as 7.0 µmol/L and a sensitivity of 38 µA·L/(mmol·cm2). The accuracy of the sensor was further validated in spiked recovery tests of human venous blood samples. The glucose recovery rate was between 99.5% and 107%, with a relative standard deviation (RSD) of less than 3.2%. These results demonstrate that our sensor has high potential for commercialization and practical application in glucose monitoring. Full article
(This article belongs to the Special Issue State-of-the-Art Biosensors in China (2nd Edition))
Show Figures

Figure 1

12 pages, 3565 KiB  
Article
Interdigitated Gear-Shaped Screen-Printed Electrode Using G-PANI Ink for Sensitive Electrochemical Detection of Dopamine
by Pritu Parna Sarkar, Ridma Tabassum, Ahmed Hasnain Jalal, Ali Ashraf and Nazmul Islam
J. Sens. Actuator Netw. 2024, 13(6), 84; https://doi.org/10.3390/jsan13060084 - 6 Dec 2024
Cited by 1 | Viewed by 1843
Abstract
In this research, a novel interdigitated gear-shaped, graphene-based electrochemical biosensor was developed for the detection of dopamine (DA). The sensor’s innovative design improves the active surface area by 94.52% and 57% compared to commercially available Metrohm DropSens 110 screen-printed sensors and printed circular [...] Read more.
In this research, a novel interdigitated gear-shaped, graphene-based electrochemical biosensor was developed for the detection of dopamine (DA). The sensor’s innovative design improves the active surface area by 94.52% and 57% compared to commercially available Metrohm DropSens 110 screen-printed sensors and printed circular sensors, respectively. The screen-printed electrode was fabricated using laser processing and modified with graphene polyaniline conductive ink (G-PANI) to enhance its electrochemical properties. Fourier Transform Infrared (FTIR) Spectroscopy and X-ray diffraction (XRD) were employed to characterize the physiochemical properties of the sensor. Dopamine, a neurotransmitter crucial for several body functions, was detected within a linear range of 0.1–100 µM, with a Limit of Detection (LOD) of 0.043 µM (coefficient of determination, R2 = 0.98) in phosphate-buffer saline (PBS) with ferri/ferrocyanide as the redox probe. The performance of the sensor was evaluated using cyclic voltammetry (CV) and Chronoamperometry, demonstrating high sensitivity and selectivity. The interdigitated gear-shaped design exhibited excellent repeatability, with a relative standard deviation (RSD) of 1.2% (n = 4) and reproducibility, with an RSD of 2.3% (n = 4). In addition to detecting dopamine in human serum, the sensor effectively distinguished dopamine in a ternary mixture containing uric acid (UA) and ascorbic acid (AA). Overall, this novel sensor design offers a reliable, disposable, and cost-effective solution for dopamine detection, with potential applications in medical diagnostics and neurological research. Full article
(This article belongs to the Section Actuators, Sensors and Devices)
Show Figures

Graphical abstract

12 pages, 2643 KiB  
Article
A Novel Methylene Blue Indicator-Based Aptasensor for Rapid Detection of Pseudomonas aeruginosa
by Somayeh Maghsoomi, Julia Walochnik, Martin Brandl and Mai-Lan Pham
Int. J. Mol. Sci. 2024, 25(21), 11682; https://doi.org/10.3390/ijms252111682 - 30 Oct 2024
Cited by 2 | Viewed by 1888
Abstract
Pseudomonas aeruginosa is a significant opportunistic pathogen highly prevalent in the environment, requiring early detection methods to prevent infections in vulnerable individuals. The most specific aptamer for P. aeruginosa, F23, has been used for the development of various assays and sensors for [...] Read more.
Pseudomonas aeruginosa is a significant opportunistic pathogen highly prevalent in the environment, requiring early detection methods to prevent infections in vulnerable individuals. The most specific aptamer for P. aeruginosa, F23, has been used for the development of various assays and sensors for early diagnosis and monitoring. In this study, a novel F23-based electrochemical aptasensor was designed using disposal gold screen-printed electrodes (Au-SPEs) with high reproducibility. Methylene blue (MB) was used as an exogenous indicator, which significantly amplified the electrochemical signal and improved the sensitivity of detection. The aptasensor explored a limit of detection (LOD) of 8 CFU·mL−1 and high selectivity for P. aeruginosa over other interfering bacteria. Furthermore, it showed potential to detect P. aeruginosa in tap water samples, offering a point-of-care tool for rapidly controlling the growth of this bacterium in various applications. Full article
(This article belongs to the Special Issue Recent Advances on Bioreceptors and Nanomaterial-Based Biosensors)
Show Figures

Figure 1

16 pages, 4478 KiB  
Article
Gold Nanoparticle-Embedded Thiol-Functionalized Ti3C2Tx MXene for Sensitive Electrochemical Sensing of Ciprofloxacin
by Mari Elancheziyan, Manisha Singh and Keehoon Won
Nanomaterials 2024, 14(20), 1655; https://doi.org/10.3390/nano14201655 - 15 Oct 2024
Cited by 7 | Viewed by 2028
Abstract
The unregulated use of ciprofloxacin (CIPF) has led to increased resistance in patients and has threatened human health with issues such as digestive disorders, kidney disorders, and liver complications. In order to overcome these concerns, this work introduces a portable electrochemical sensor based [...] Read more.
The unregulated use of ciprofloxacin (CIPF) has led to increased resistance in patients and has threatened human health with issues such as digestive disorders, kidney disorders, and liver complications. In order to overcome these concerns, this work introduces a portable electrochemical sensor based on a disposable integrated screen-printed carbon electrode (SPCE) coated with gold nanoparticle-embedded thiol-functionalized Ti3C2Tx MXene (AuNPs-S-Ti3C2Tx MXene) for simple, rapid, precise, and sensitive quantification of CIPF in milk and water samples. The high surface area and electrical conductivity of AuNPs are maximized thanks to the strong interaction between AuNPs and SH-Ti3C2Tx MXene, which can prevent the aggregation of AuNPs and endow larger electroactive areas. Ti3C2Tx MXene was synthesized from Ti3AlC2 MAX phases, and its thiol functionalization was achieved using 3-mercaptopropyl trimethoxysilane. The prepared AuNPs-S-Ti3C2Tx MXene nanocomposite was characterized using FESEM, EDS, XRD, XPS, FTIR, and UV–visible spectroscopy. The electrochemical behavior of the nanocomposite was examined using CV, EIS, DPV, and LSV. The AuNPs-S-Ti3C2Tx MXene/SPCE showed higher electrochemical performances towards CIPF oxidation than a conventional AuNPs-Ti3C2Tx MXene/SPCE. Under the optimized DPV and LSV conditions, the developed nonenzymatic CIPF sensor displayed a wide range of detection concentrations from 0.50 to 143 μM (DPV) and from 0.99 to 206 μM (LSV) with low detection limits of 0.124 μM (DPV) and 0.171 μM (LSV), and high sensitivities of 0.0863 μA/μM (DPV) and 0.2182 μA/μM (LSV). Full article
Show Figures

Graphical abstract

26 pages, 4155 KiB  
Review
Enhancing Sensitivity and Selectivity: Current Trends in Electrochemical Immunosensors for Organophosphate Analysis
by Yin Shen, Shichao Zhao, Fei Chen, Yanfei Lv and Li Fu
Biosensors 2024, 14(10), 496; https://doi.org/10.3390/bios14100496 - 12 Oct 2024
Cited by 7 | Viewed by 2507
Abstract
This review examines recent advancements in electrochemical immunosensors for the detection of organophosphate pesticides, focusing on strategies to enhance sensitivity and selectivity. The widespread use of these pesticides has necessitated the development of rapid, accurate, and field-deployable detection methods. We discuss the fundamental [...] Read more.
This review examines recent advancements in electrochemical immunosensors for the detection of organophosphate pesticides, focusing on strategies to enhance sensitivity and selectivity. The widespread use of these pesticides has necessitated the development of rapid, accurate, and field-deployable detection methods. We discuss the fundamental principles of electrochemical immunosensors and explore innovative approaches to improve their performance. These include the utilization of nanomaterials such as metal nanoparticles, carbon nanotubes, and graphene for signal amplification; enzyme-based amplification strategies; and the design of three-dimensional electrode architectures. The integration of these sensors into microfluidic and lab-on-a-chip devices has enabled miniaturization and automation, while screen-printed and disposable electrodes have facilitated on-site testing. We analyze the challenges faced in real sample analysis, including matrix effects and the stability of biological recognition elements. Emerging trends such as the application of artificial intelligence for data interpretation and the development of aptamer-based sensors are highlighted. The review also considers the potential for commercialization and the hurdles that must be overcome for widespread adoption. Future research directions are identified, including the development of multi-analyte detection platforms and the integration of sensors with emerging technologies like the Internet of Things. This comprehensive overview provides insights into the current state of the field and outlines promising avenues for future development in organophosphate pesticide detection. Full article
(This article belongs to the Special Issue State-of-the-Art Biosensors in China (2nd Edition))
Show Figures

Figure 1

21 pages, 4361 KiB  
Article
Curcumin-Based Molecularly Imprinted Polymer Electropolymerized on Single-Use Graphite Electrode for Dipyridamole Analysis
by Daniel Preda, Gabriel Lucian Radu, Emilia-Elena Iorgulescu, Mihaela-Carmen Cheregi and Iulia Gabriela David
Molecules 2024, 29(19), 4630; https://doi.org/10.3390/molecules29194630 - 29 Sep 2024
Viewed by 1163
Abstract
A new molecularly imprinted polymer (MIP)-based disposable electrochemical sensor for dipyridamole (DIP) determination was obtained. The sensor was rapidly prepared by potentiodynamic electrochemical polymerization on a pencil graphite electrode (PGE) using curcumin (CUR) as a functional monomer and DIP as a template molecule. [...] Read more.
A new molecularly imprinted polymer (MIP)-based disposable electrochemical sensor for dipyridamole (DIP) determination was obtained. The sensor was rapidly prepared by potentiodynamic electrochemical polymerization on a pencil graphite electrode (PGE) using curcumin (CUR) as a functional monomer and DIP as a template molecule. After the optimization of the conditions (pH, monomer–template ratio, scan rate, number of cyclic voltammetric cycles applied in the electro-polymerization process and extraction time of the template molecule) for MIP formation, DIP voltammetric behavior at the modified electrode (MIP_PGE) was investigated. DIP oxidation took place in a pH-dependent, irreversible mixed diffusion-adsorption controlled process. Differential pulse voltammetry (DPV) and adsorptive stripping differential pulse voltammetry (AdSDPV) were used to quantify DIP from pharmaceutical and tap water samples. Under optimized conditions (Britton–Robinson buffer at pH = 3.29), the obtained linear ranges were 5.00 × 10−8–1.00 × 10−5 mol/L and 5.00 × 10−9–1.00 × 10−7 mol/L DIP for DPV and AdSDPV, respectively. The limits of detection of the methods were 1.47 × 10−8 mol/L for DPV and 3.96 × 10−9 mol/L DIP for AdSDPV. Full article
(This article belongs to the Section Analytical Chemistry)
Show Figures

Figure 1

13 pages, 4048 KiB  
Article
Portable Electrochemical Immunosensor Based on a Gold Microblobs-Optimized Screen-Printed Electrode for SARS-CoV-2 Diagnosis
by Melissa M. Giacomet, Paulo H. M. Buzzetti, Oscar O. S. Junior, Alessandro F. Martins, Elton G. Bonafe and Johny P. Monteiro
Inorganics 2024, 12(9), 252; https://doi.org/10.3390/inorganics12090252 - 18 Sep 2024
Cited by 1 | Viewed by 1413
Abstract
The development of biosensors for determining the most diverse biomolecules is a constant focus of many research groups. There is a latent need to propose sensors that combine portability, simple measurements, and good analytical performance. Here, we propose an electrochemical immunosensor that is [...] Read more.
The development of biosensors for determining the most diverse biomolecules is a constant focus of many research groups. There is a latent need to propose sensors that combine portability, simple measurements, and good analytical performance. Here, we propose an electrochemical immunosensor that is fully portable and energy-independent for diagnosing antibodies against SARS-CoV-2 (the virus that causes COVID-19). Initially, disposable screen-printed carbon electrodes (SPEs) were covered by gold microblobs (AuMBs), which were synthesized amperometrically from Au3+ ions. Then, the SPE-AuMBs were coated with cysteamine, which allowed the N-hydroxysuccinimide-activated SARS-CoV-2 antigen (spike protein) to be immobilized. The antigen-activated electrode was used to detect COVID-19 antibodies from current measurements obtained by differential pulse voltammetry. The AuMBs synthesis time was optimized, and the presence of gold structures improved the electrochemical responses of the SPE. It was possible to quantitatively determine antibodies in the concentration range of 0.25 to 10 µg mL−1. This range includes concentrations found in biological fluids from patients at any stage of the disease. An analysis took approximately the same time as traditional rapid nasal tests (20 min) and costed less, considering all the steps necessary to prepare a disposable antigen-functionalized SPE. Full article
Show Figures

Graphical abstract

Back to TopTop