Search Parameters:
Keywords = concrete moisture diffusion model

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 7814 KB  
Article
Numerical Solution for Chloride Transport at the Corners of Square Piles Subjected to Wetting–Drying Cycles
by Siyang Wu, Xiaodong Shao, Xiaolong Ding, Lü Liu, Dong Huang, Guoxiong Mei and Wenbing Wu
Appl. Sci. 2026, 16(16), 8227; https://doi.org/10.3390/app16168227 - 18 Aug 2026
Viewed by 166
Abstract
The durability of marine concrete square piles is critically governed by chloride transport at the corners of piles, regions subject to multi-directional erosion and pronounced accumulation under cyclic wetting–drying conditions. In this study, we developed a two-dimensional coupled moisture–chloride convection–diffusion model for a [...] Read more.
The durability of marine concrete square piles is critically governed by chloride transport at the corners of piles, regions subject to multi-directional erosion and pronounced accumulation under cyclic wetting–drying conditions. In this study, we developed a two-dimensional coupled moisture–chloride convection–diffusion model for a quarter section of the corner of a square pile, incorporating the time-dependent surface chloride concentration and a nonlinear moisture diffusion coefficient. The governing equations were numerically solved using the unconditionally stable alternating direction implicit (ADI) finite-difference method, which effectively overcomes the instability issues inherent in long-term simulations of strongly coupled systems. Model predictions were validated against experimental data from the literature, showing good agreement. Parametric investigations revealed that (1) the effect of moisture–chloride coupling is significant, with a low initial degree of saturation intensifying capillary-driven convection and accelerating early-stage chloride ingress; (2) a higher water-to-cement ratio markedly increases pore connectivity, exacerbating chloride accumulation under bidirectional erosion; and (3) increasing the drying-to-wetting time ratio effectively reduces net chloride buildup by curtailing the total duration of immersion. These findings provide a theoretical foundation for durability design and service-life assessment regarding square pile foundations in marine tidal and splash zones. Full article
(This article belongs to the Topic Durability of Structure and Construction Materials)
Show Figures

Figure 1

16 pages, 1094 KB  
Article
The One-Dimensional Moisture Transport Model for Concrete Under Dry–Wet Cycles
by Yanjuan Chen, Luping Tang, Jianming Gao, Shuping Wang and Guangxuan Wang
Buildings 2026, 16(11), 2204; https://doi.org/10.3390/buildings16112204 - 30 May 2026
Viewed by 527
Abstract
This study proposes a novel analytical model to predict one-dimensional moisture transport in concrete under cyclic drying and wetting conditions. The framework distinguishes between two physical mechanisms: diffusion-driven evaporation during drying and capillary-driven suction during wetting. Governing equations for weight loss and gain [...] Read more.
This study proposes a novel analytical model to predict one-dimensional moisture transport in concrete under cyclic drying and wetting conditions. The framework distinguishes between two physical mechanisms: diffusion-driven evaporation during drying and capillary-driven suction during wetting. Governing equations for weight loss and gain are derived for each respective phase. During the drying phase, weight loss follows a linear relationship with the square root of time, allowing the diffusion coefficient to be determined via evaporation tests. For the wetting phase, a modified sorptivity approach is employed, incorporating an error-function baseline to account for residual moisture. A calibration coefficient of ε is utilized to correct for varying conditions between standard water suction tests and environmental wetting, particularly for air-entrained concrete characterized by larger capillary volumes and complex tortuosity. Experimental validation was conducted on concrete with varying water-to-cement ratios. The model demonstrated excellent agreement with experimental data, maintaining relative errors below 10% for standard mixes. While higher-porosity samples exhibited greater scatter due to “water traps” and complex pore structures, the model effectively captured cumulative moisture trends over multiple cycles. This framework provides a robust tool for assessing the durability of concrete structures in unsheltered environments. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

20 pages, 11450 KB  
Article
A Novel Simulation Method for the Spatiotemporal Variation in Relative Humidity in Early Age of Polypropylene Fibers Reinforced Concrete
by Zhaohui Chen, Linsong Shen, Wangdui Gerong, Fengyou He, Hongyu Zhao and Junbo Sun
Buildings 2025, 15(22), 4032; https://doi.org/10.3390/buildings15224032 - 8 Nov 2025
Viewed by 574
Abstract
Early-age cracking remains a major durability challenge for concrete. It is primarily caused by internal restraint stresses induced by humidity and temperature gradients during hydration. Conventional approaches often fail to capture the coupled and non-uniform nature of heat and moisture transport, limiting their [...] Read more.
Early-age cracking remains a major durability challenge for concrete. It is primarily caused by internal restraint stresses induced by humidity and temperature gradients during hydration. Conventional approaches often fail to capture the coupled and non-uniform nature of heat and moisture transport, limiting their ability to predict cracking risk and evaluate mitigation strategies. To address this limitation, we characterize the spatiotemporal evolution of internal humidity and temperature using a spatial coefficient of variation. From a numerical standpoint, the influence of polypropylene fibers (PPFs) on internal relative humidity is elucidated by adopting an unconditionally stable backward-Euler finite-difference scheme to resolve multiple coupled physicochemical processes—hydration, heat release, self-desiccation, heat and moisture diffusion to the environment—and their mutual interactions. Furthermore, a one-dimensional homogeneous random-field model is proposed to quantify the spatial non-uniformity of humidity in PPF concrete. On this basis, the effects of polypropylene fibers (PPFs) in mitigating internal humidity is quantitatively revealed. Good agreement is achieved between simulations and tests, with standard deviations of 0.0119 for normal concrete and 0.0041 for PPF concrete, thereby validating the model’s predictive capability for the spatiotemporal distribution of internal relative humidity (RH) in PPF concrete. According to the numerical analysis, owing to the moisture-sorption characteristics of PPFs, at a depth of 25 mm, the internal RH in PPF concrete has decreased by 16% at 28 days, whereas normal concrete exhibits a 28% decrease. With increasing depth, the RH reduction at 28 days is approximately 13% for both PPF concrete and plain concrete, and the time-dependent evolution of RH in PPF concrete is broadly similar to that of normal concrete. Furthermore, the mitigating influence of PPFs decreases with hydration age and distance from the surface, reflecting the gradual decline of diffusion heterogeneity over time and depth. These findings provide new numerical evidence for the effectiveness of PPFs in reducing the early-age cracking risk in concrete. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

17 pages, 1980 KB  
Article
Digital Twin Model for Predicting Hygrothermal Performance of Building Materials from Moisture Permeability Tests
by Anna Szymczak-Graczyk, Jacek Korentz and Tomasz Garbowski
Materials 2025, 18(18), 4360; https://doi.org/10.3390/ma18184360 - 18 Sep 2025
Cited by 16 | Viewed by 1338
Abstract
Moisture transport in building materials significantly influences their durability, mechanical integrity, and thermal performance. This study presents an experimental investigation of moisture permeability in a range of traditional and modern wall elements, including autoclaved aerated concrete (ACC), ceramic blocks, silicate blocks, perlite concrete [...] Read more.
Moisture transport in building materials significantly influences their durability, mechanical integrity, and thermal performance. This study presents an experimental investigation of moisture permeability in a range of traditional and modern wall elements, including autoclaved aerated concrete (ACC), ceramic blocks, silicate blocks, perlite concrete blocks, and concrete units. Both vapor diffusion and capillary transport mechanisms were analyzed under controlled climatic conditions using gravimetric and hygrometric methods. Among the tested materials, autoclaved aerated concrete (AAC) was selected for detailed numerical modeling because of its high porosity, strong capillarity, and widespread use in modern construction, which make it especially vulnerable to moisture-related degradation. Based on the experimental findings, a digital twin was developed to simulate hygrothermal behavior of walls made of ACC under various environmental conditions. The model incorporates advanced moisture transport equations, capturing diffusion and capillary effects while considering real-world variables, such as relative humidity, temperature fluctuations, and wetting–drying cycles. Calibration demonstrated strong agreement with experimental data, enabling reliable predictions of moisture behavior over extended exposure scenarios. This integrated approach provides a robust engineering tool for assessing the long-term material performance of AAC, predicting degradation risks, and optimizing material selection in humid climates. The study illustrates how coupling experimental data with digital modeling can enhance the design of moisture-resistant and durable building envelopes. Full article
(This article belongs to the Section Construction and Building Materials)
Show Figures

Figure 1

18 pages, 9340 KB  
Article
Prediction of Compressive Strength of Concrete Considering Pore Relative Humidity
by Gyeonghee An
Materials 2025, 18(12), 2859; https://doi.org/10.3390/ma18122859 - 17 Jun 2025
Cited by 1 | Viewed by 1074
Abstract
This study investigates a prediction method for the compressive strength of concrete considering the pore relative humidity. Water within concrete not only facilitates the bonding of cementitious materials and aggregates but also influences the pore structure, thus affecting the compressive strength of concrete. [...] Read more.
This study investigates a prediction method for the compressive strength of concrete considering the pore relative humidity. Water within concrete not only facilitates the bonding of cementitious materials and aggregates but also influences the pore structure, thus affecting the compressive strength of concrete. While the relationship between the water–cement ratio and mechanical properties has been extensively explored, the quantitative effects of curing and moisture history on compressive strength remain insufficiently demonstrated. This research aims to fill this gap by proposing predictive models that consider the history of pore humidity. Experimental data from previous studies were utilized to develop and verify these models. Pore humidity was assessed through self-desiccation and diffusion processes. A self-desiccation model was formulated based on existing experimental results, and the finite element method was employed for diffusion analysis. The prediction model for compressive strength was derived from the rate constant model, incorporating apparent activation energy and adjusting for various curing conditions. The proposed models provide a robust framework for predicting the compressive strength of concrete under diverse curing scenarios. This research contributes to the development of practical tools for ensuring the safety and durability of concrete structures in the construction industry. Full article
(This article belongs to the Section Construction and Building Materials)
Show Figures

Figure 1

25 pages, 2915 KB  
Article
Meshless Numerical Simulation on Dry Shrinkage Cracking of Concrete Piles for Offshore Wind Power Turbine
by Cong Hu, Jianfeng Xue, Taicheng Li, Haiying Mao, Haotian Chang and Wenbing Zhang
Buildings 2025, 15(12), 2006; https://doi.org/10.3390/buildings15122006 - 11 Jun 2025
Cited by 1 | Viewed by 955
Abstract
Against the backdrop of the global energy transition, offshore wind power has undergone rapid development. As a vital component of offshore wind power infrastructure, dry shrinkage cracking in concrete piles poses a significant threat to the safe and stable operation of offshore wind [...] Read more.
Against the backdrop of the global energy transition, offshore wind power has undergone rapid development. As a vital component of offshore wind power infrastructure, dry shrinkage cracking in concrete piles poses a significant threat to the safe and stable operation of offshore wind power systems. However, the fundamental mechanism of concrete pile cracking during dry shrinkage—particularly the coupled effects of moisture diffusion, meso-structural heterogeneity, and stress evolution—remains poorly understood, lacking a unified theoretical framework. This knowledge gap hinders the development of targeted anti-cracking strategies for offshore concrete structures. Hence, investigating the mechanism of dry shrinkage cracking is of substantial importance. This paper employs numerical simulation to explore the patterns and influencing factors of dry shrinkage cracking in concrete piles for offshore wind turbines, aiming to provide theoretical support for enhancing pile performance. A meshless numerical simulation method based on the smoothed particle hydrodynamics (SPH) framework is developed, which generates concrete meso-structures via a specific algorithm, discretizes the moisture diffusion equation, defines dry shrinkage stress terms, and introduces a fracture coefficient to characterize particle failure, enabling the simulation of concrete dry shrinkage cracking processes. Simulation schemes are designed for varying aggregate percentages, aggregate particle sizes, dry shrinkage coefficients, and moisture diffusion coefficients, using a 100 mm-diameter circular concrete model. Qualitative results reveal the following: Increased aggregate percentages lead to more uniform moisture diffusion, with dry shrinkage crack number and length first increasing and then decreasing; larger aggregate particle sizes exacerbate moisture diffusion non-uniformity and intensify dry shrinkage cracking; higher dry shrinkage coefficients correlate with increased crack number and length; elevated moisture diffusion coefficients accelerate surface water loss, with cracking severity first increasing and then decreasing. The proposed SPH-based meshless method effectively simulates dry shrinkage cracking in offshore wind turbine concrete piles, demonstrating the significant impact of different factors on moisture diffusion and cracking patterns. This study offers insights for applying the SPH method in related fields, deepens the understanding of concrete dry shrinkage cracking mechanisms, and provides a theoretical foundation for the design and optimization of offshore wind power concrete piles. Full article
(This article belongs to the Special Issue Low Carbon and Green Materials in Construction—3rd Edition)
Show Figures

Figure 1

22 pages, 3210 KB  
Article
Development and Validation of a Coupled Hygro-Chemical and Thermal Transport Model in Concrete Using Parallel FEM
by Okpin Na and Giyeol Lee
Appl. Sci. 2025, 15(11), 5989; https://doi.org/10.3390/app15115989 - 26 May 2025
Cited by 1 | Viewed by 1313
Abstract
The durability of reinforced concrete structures in aggressive environments is strongly influenced by the ingress of chloride and other harmful ions, which is further complicated under partially saturated conditions, due to the coexistence of liquid and gas phases within the pore network. This [...] Read more.
The durability of reinforced concrete structures in aggressive environments is strongly influenced by the ingress of chloride and other harmful ions, which is further complicated under partially saturated conditions, due to the coexistence of liquid and gas phases within the pore network. This study aimed to develop a predictive moisture–chemical–temperature model and to elucidate the mechanisms governing ion transport in partially saturated concrete. A multi-species hygro-chemo-thermo transport model was formulated based on the Nernst–Planck equation, incorporating electroneutrality, zero current conditions, and the coupled effects of moisture and temperature gradients. The model was numerically implemented using a parallel FE method with the Crank–Nicolson scheme, supported by domain decomposition and SPMD techniques for high computational efficiency. As a result, experimental validation was performed through chloride ponding tests under varying temperature conditions (20 °C, 35 °C, 50 °C), water-to-cement ratios (0.55, 0.65), and relative humidity differences (100%, 60%). The simulation results showed good agreement with the experimental data and confirmed that the proposed model can effectively predict chloride penetration under both isothermal and non-isothermal conditions. Additionally, the simulations revealed that moisture gradients accelerate ion transport, as the inward migration of the moisture front enhances the diffusion rates of chloride, sodium, and calcium ions until a steady-state moisture distribution is reached. Full article
Show Figures

Figure 1

18 pages, 7033 KB  
Article
Study of Concrete Moisture Transfer Characteristics in the Presence of the Concrete Micro–Meso Structure Effect
by Xiaogang Zhang, Shuhua Zhang, Bofu Chen, Bin Tian, Xiaochun Lu, Bobo Xiong and Zhao Pan
Appl. Sci. 2025, 15(4), 1774; https://doi.org/10.3390/app15041774 - 10 Feb 2025
Cited by 4 | Viewed by 2024
Abstract
Water and water transfer are the keys of the concrete durability problem; the non-uniform moisture transfer caused by the concrete micro–meso structure has a great effect on the drying shrinkage crack, transfers of inimical ions, etc. For the non-uniform moisture transfer problem, a [...] Read more.
Water and water transfer are the keys of the concrete durability problem; the non-uniform moisture transfer caused by the concrete micro–meso structure has a great effect on the drying shrinkage crack, transfers of inimical ions, etc. For the non-uniform moisture transfer problem, a multi-scale concrete moisture diffusion coefficient model which can consider the effect of Knudsen diffusion was established and verified based on the moisture transfer mechanism of porous medium and the concrete micro–meso structure characteristics. The effects of pore structure, the interfacial transition zone, and aggregate on the concrete moisture diffusion coefficient were studied based on the model, and the non-uniform moisture transfer characteristics and differences in concrete wetting and drying were analyzed via simulations. The results show that the moisture transfers more easily via the pores ranging from 10 nm to 100 nm, the effect of Knudsen diffusion increases with the increasing water-to-cement ratio and decreases with the increasing relative moisture, and Knudsen diffusion is also an effect factor which causes the moisture diffusion coefficient to increase with the increase in moisture. Moisture transfers more easily via the interfacial transition zone at the meso-level and causes a “flow around” phenomenon. The “S” growth relation between the moisture diffusion coefficient and relative moisture can consider the differences in the moisture diffusion coefficient under wetting and drying conditions to a certain extent, which makes concrete wet faster than dry. In addition, the jumping growth of the moisture diffusion coefficient in the relation also leads to an “inflection point” in the concrete moisture distribution. Full article
(This article belongs to the Special Issue Structural Health Monitoring for Concrete Dam)
Show Figures

Figure 1

20 pages, 11003 KB  
Article
An Integrated Model for Mass Transport, Corrosion Propagation, and Cracking in Offshore Reinforced Concrete Structures
by Wenchao Li, Huaikuan Wang, Jiangshun Wu, Bo Zhang, Yuming Lai, Feifei Huang and Ying Jin
Coatings 2025, 15(2), 172; https://doi.org/10.3390/coatings15020172 - 3 Feb 2025
Viewed by 1838
Abstract
The corrosion of steel reinforcements substantially degrades the longevity of reinforced concrete structures, particularly in marine settings. This investigation introduces a comprehensive model that simulates the processes involved in moisture and chloride ion transport, rebar corrosion, and the consequent cracking of concrete. The [...] Read more.
The corrosion of steel reinforcements substantially degrades the longevity of reinforced concrete structures, particularly in marine settings. This investigation introduces a comprehensive model that simulates the processes involved in moisture and chloride ion transport, rebar corrosion, and the consequent cracking of concrete. The model reveals that the transport dynamics of chloride ions are primarily dictated by their penetration rates through the solution. The sensitivity of the steel to corrosion is a function of the concentrations of water and chloride ions, whereas the rate of corrosion predominantly depends on the availability of oxygen at the corrosive site. Oxygen diffusion is the rate-limiting step in the entire process of the electrochemical reactions of the rebar. And the peak corrosion rates are observed at the interface between the solution and the gas phase. The model calculates the stress and strain in the concrete resulting from volumetric expansion due to oxidization of the steel bars. By accurately reproducing the progression of corrosion-related damage, this model provides crucial insights for predicting the service life of offshore concrete structures and enhancing durability against aggressive environmental conditions. Full article
(This article belongs to the Special Issue Alloy/Metal/Steel Surface: Fabrication, Structure, and Corrosion)
Show Figures

Graphical abstract

14 pages, 4677 KB  
Article
Experimental Investigation of Water Vapor Concentration on Fracture Properties of Asphalt Concrete
by Yu Chen, Tingting Huang, Xuqing Wen, Kai Zhang and Zhengang Li
Materials 2024, 17(13), 3289; https://doi.org/10.3390/ma17133289 - 3 Jul 2024
Cited by 3 | Viewed by 2341
Abstract
The effect of moisture on the fracture resistance of asphalt concrete is a significant concern in pavement engineering. To investigate the effect of the water vapor concentration on the fracture properties of asphalt concrete, this study first designed a humidity conditioning program at [...] Read more.
The effect of moisture on the fracture resistance of asphalt concrete is a significant concern in pavement engineering. To investigate the effect of the water vapor concentration on the fracture properties of asphalt concrete, this study first designed a humidity conditioning program at the relative humidity (RH) levels of 2%, 50%, 80%, and 100% for the three types of asphalt concrete mixtures (AC-13C, AC-20C, and AC-25C).The finite element model was developed to simulate the water vapor diffusion and determine the duration of the conditioning period. The semi-circular bending (SCB) test was then performed at varying temperatures of 5 °C, 15 °C, and 25 °C to evaluate the fracture energy and tensile strength of the humidity-conditioned specimens. The test results showed that the increasing temperature and the RH levels resulted in a lower peak load but greater displacement of the mixtures. Both the fracture energy and tensile strength tended to diminish with the rising temperature. It was also found that moisture had a significant effect on the tensile strength and fracture energy of asphalt concrete. Specifically, as the RH level increased from 2% to 100% (i.e., the water vapor concentration rose from 0.35 g/m3 to 17.27 g/m3), the tensile strength of the three types of mixtures was reduced by 34.84% on average, which revealed that the water vapor led to the loss of adhesion and cohesion within the mixture. The genetic expression programming (GEP) model was developed to quantify the effect of water vapor concentrations and temperature on the fracture indices. Full article
Show Figures

Figure 1

25 pages, 18279 KB  
Article
Moisture Diffusion Coefficient of Concrete under Different Conditions
by Fengbin Zhou, Wenhao Li, Ying Hu, Lepeng Huang, Zhuolin Xie, Jun Yang, Daifeng Wu and Zhonghao Chen
Buildings 2023, 13(10), 2421; https://doi.org/10.3390/buildings13102421 - 22 Sep 2023
Cited by 41 | Viewed by 5558
Abstract
Humidity change in concrete is the leading cause of concrete shrinkage. Moreover, the moisture diffusion coefficient of concrete is an essential parameter for assessing and predicting the internal moisture content of concrete. However, there is a lack of theoretical construction and experimental studies [...] Read more.
Humidity change in concrete is the leading cause of concrete shrinkage. Moreover, the moisture diffusion coefficient of concrete is an essential parameter for assessing and predicting the internal moisture content of concrete. However, there is a lack of theoretical construction and experimental studies on the effect of different conditions, especially different constraints, on the moisture diffusion coefficient of concrete. Therefore, the internal humidity, pore structure parameters, and basic mechanical properties of concrete under different strength grades C30, C40, C50, and C60 (C stands for concrete and numbers indicate the strength class of the concrete), curing environments (dry and sealed curing conditions), and constraints were tested in this study. In addition, a calculation model of concrete’s internal humidity and humidity diffusion coefficient was established. The research findings show that the internal humidity of concrete decreased with age due to hydration and drying. External humidity had a significant effect on the moisture change of concrete, and the lower the external humidity, the larger the humidity diffusion coefficient and the faster the internal humidity of concrete decreases. Reinforcement (confinement) changes the pore structure parameters of the concrete, which in turn affects the transport of moisture within the concrete. The higher the reinforcement rate, the larger the pore structure parameters of the concrete, the larger the humidity diffusion coefficient, and the faster the concrete humidity decreases. The method proposed in the study can accurately predict the internal humidity of concrete using the humidity diffusion coefficient. The research results are a reference for preventing concrete shrinkage and cracking in construction. Full article
(This article belongs to the Special Issue Research on the Crack Control of Concrete)
Show Figures

Figure 1

18 pages, 13312 KB  
Article
Coupled Effect of Chloride Corrosion and Repeated Uniaxial Compressive Loading on Unsaturated Concrete
by Bing Han, Ziwei Song, Jinquan Zhang, Huibing Xie, Wutong Yan, Yun Liu and Jiaping Yu
Materials 2023, 16(8), 2947; https://doi.org/10.3390/ma16082947 - 7 Apr 2023
Cited by 3 | Viewed by 2213
Abstract
Concrete structure performance continuously deteriorates during operation, and the performance is simultaneously affected by chloride corrosion and repeated traffic loading. Repeated-loading-induced cracks have an impact on the rate of chloride corrosion. Chloride-induced concrete corrosion also affect the stress level of the structure under [...] Read more.
Concrete structure performance continuously deteriorates during operation, and the performance is simultaneously affected by chloride corrosion and repeated traffic loading. Repeated-loading-induced cracks have an impact on the rate of chloride corrosion. Chloride-induced concrete corrosion also affect the stress level of the structure under loading. Therefore, the coupled effect of repeated loading and chloride corrosion on the structural performance needs to be investigated. An upgraded test device was developed for chloride corrosion testing of unsaturated concrete structures under repeated loading. Based on the experimental results, considering the influence of repeated loading on the moisture diffusion coefficient and the chloride diffusion coefficient, a chloride transport model for unsaturated concrete under the coupled effect of repeated uniaxial compressive loading and corrosion was established. The chloride concentration under coupled loading was determined by the Crank–Nicolson finite difference method and the Thomas algorithm, and then chloride transport under the coupled effect of repeated loading and corrosion was analyzed. The results showed that the stress level and the repeated loading cycles directly affect the relative volumetric water content and chloride concentration in unsaturated concrete. The effect of chloride corrosion is more severe in unsaturated concrete compared to saturated concrete. Full article
Show Figures

Figure 1

17 pages, 6014 KB  
Article
Inverse Estimation of Moisture Diffusion Model for Concrete Using Artificial Neural Network
by Jae Min Lee and Chang Joon Lee
Materials 2022, 15(17), 5945; https://doi.org/10.3390/ma15175945 - 28 Aug 2022
Cited by 1 | Viewed by 2044
Abstract
In this research, the moisture diffusion model for concrete was inversely estimated using artificial neural network (ANN) and the data collected from virtual experiments. In addition, the moisture distribution was predicted using the ANN model in numerical analysis. For inverse estimation, virtual experimental [...] Read more.
In this research, the moisture diffusion model for concrete was inversely estimated using artificial neural network (ANN) and the data collected from virtual experiments. In addition, the moisture distribution was predicted using the ANN model in numerical analysis. For inverse estimation, virtual experimental data were used. The virtual experimental data were generated by adding noise to the moisture distribution obtained by a numerical simulation using a known moisture diffusion model. ANNs of two architectures were used in the inverse estimation. For performance test, the inversely estimated ANN model and the known moisture diffusion model were compared. The predicted humidity distribution using the ANN and virtual experiment data were also compared. The inversely estimated ANN model was in a good agreement with the known moisture diffusion model used for the virtual experiment. Full article
(This article belongs to the Special Issue New Advances in Cement and Concrete Research)
Show Figures

Figure 1

18 pages, 4048 KB  
Article
Climatic Issue in an Advanced Numerical Modeling of Concrete Carbonation
by Viet Duc Ngo, Ngoc Tan Nguyen, Frédéric Duprat, Ngoc Tru Vu and Viet Phuong Nguyen
Sustainability 2021, 13(11), 5994; https://doi.org/10.3390/su13115994 - 26 May 2021
Cited by 5 | Viewed by 3936
Abstract
Damage in reinforced concrete structures is frequently caused by reinforcement corrosion due to carbonation. Although a wide range of literature contributed to the concrete carbonation consisting of experimental investigations and numerical simulations, research work on a complete numerical model for concrete carbonation prediction [...] Read more.
Damage in reinforced concrete structures is frequently caused by reinforcement corrosion due to carbonation. Although a wide range of literature contributed to the concrete carbonation consisting of experimental investigations and numerical simulations, research work on a complete numerical model for concrete carbonation prediction with integrated climatic variables (e.g., temperature, relative humidity) is still a challenge. The present paper aims to propose an advanced numerical model to simulate the penetration of carbon dioxide and moisture, diffusion of calcium ions, heat transfer, and porosity modification in concrete material using COMSOL Multiphysics software. Three coupled mass conservation equations of calcium, water, and carbon dioxide are solved together with additional equations regarding the heat transfer, variation of porosity, and content of portlandite and other hydrates and calcites. In this study, the actual temporal variabilities of temperature and relative humidity in Toulouse, France, are used as a case study. The predicted results of portlandite profiles and carbonation depth are compared with the experimental data and discussed to identify the effect of climatic variables on the concrete carbonation. Full article
Show Figures

Figure 1

29 pages, 6545 KB  
Article
Multiphysics and Multiscale Modeling of Coupled Transport of Chloride Ions in Concrete
by Amit Jain and Bora Gencturk
Materials 2021, 14(4), 885; https://doi.org/10.3390/ma14040885 - 13 Feb 2021
Cited by 17 | Viewed by 3780
Abstract
Chloride ions (Cl)-induced corrosion is one of the main degradation mechanisms in reinforced concrete (RC) structures. In most situations, the degradation initiates with the transport of Cl from the surface of the concrete towards the reinforcing steel. The accumulation of [...] Read more.
Chloride ions (Cl)-induced corrosion is one of the main degradation mechanisms in reinforced concrete (RC) structures. In most situations, the degradation initiates with the transport of Cl from the surface of the concrete towards the reinforcing steel. The accumulation of Cl at the steel-concrete interface could initiate reinforcement corrosion once a threshold Cl concentration is achieved. An accurate numerical model of the Cl transport in concrete is required to predict the corrosion initiation in RC structures. However, existing numerical models lack a representation of the heterogenous concrete microstructure resulting from the varying environmental conditions and the indirect effect of time dependent temperature and relative humidity (RH) on the water adsorption and Cl binding isotherms. In this study, a numerical model is developed to study the coupled transport of Cl with heat, RH and oxygen (O2) into the concrete. The modeling of the concrete microstructure is performed using the Virtual Cement and Concrete Testing Laboratory (VCCTL) code developed by the U.S. National Institute of Standards and Technology (NIST). The concept of equivalent maturation time is utilized to eliminate the limitation of simulating concrete microstructure using VCCTL in specific environmental conditions such as adiabatic. Thus, a time-dependent concrete microstructure, which depends on the hydration reactions coupled with the temperature and RH of the environment, is achieved to study the Cl transport. Additionally, Cl binding isotherms, which are a function of the pH of the concrete pore solution, Cl concentration, and weight fraction of mono-sulfate aluminate (AFm) and calcium-silicate-hydrate (C-S-H), obtained from an experimental study by the same authors are utilized to account for the Cl binding of cement hydration products. The temperature dependent RH diffusion was considered to account for the transport of Cl with moisture transport. The temperature and RH diffusion in the concrete domain, composite theory, and Cl binding and water adsorption isotherms are used in combination, to estimate the ensuing Cl diffusion field within the concrete. The coupled transport process of heat, RH, Cl, and O2 is implemented in the Multiphysics Object-Oriented Simulation Environment (MOOSE) developed by the U.S. Idaho National Laboratory (INL). The model was verified and validated using data from multiple experimental studies with different concrete mixture proportions, curing durations, and environmental conditions. Additionally, a sensitivity analysis was performed to identify that the water-to-cement (w/c) ratio, the exposure duration, the boundary conditions: temperature, RH, surface Cl concentration, Cl diffusion coefficient in the capillary water, and the critical RH are the important parameters that govern the Cl transport in RC structures. In a case study, the capabilities of the developed numerical model are demonstrated by studying the complex 2D diffusion of Cl in a RC beam located in two different climatic regions: warm and humid weather in Galveston, Texas, and cold and dry weather in North Minnesota, Minnesota, subjected to time varying temperature, RH, and surface Cl concentrations. Full article
(This article belongs to the Special Issue Advances in Construction and Building Materials)
Show Figures