Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (118)

Search Parameters:
Keywords = blood velocity fields

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 3968 KB  
Article
Solid Dispersion Characteristics of an Oscillatory Microfluidic Mixer: An Experimental and Numerical Investigation
by Yao Lu, Haixuan Sun and Yifan Qin
Micromachines 2026, 17(9), 1036; https://doi.org/10.3390/mi17091036 - 29 Aug 2026
Viewed by 170
Abstract
Point-of-care (POC) diagnostic testing based on microfluidic technology plays an important role in coagulation management. Its precision is, however, limited by the inefficient mixing between blood and solid activators in laminar microfluidic flow. In this study, a novel micromixer incorporating periodic oscillatory flow [...] Read more.
Point-of-care (POC) diagnostic testing based on microfluidic technology plays an important role in coagulation management. Its precision is, however, limited by the inefficient mixing between blood and solid activators in laminar microfluidic flow. In this study, a novel micromixer incorporating periodic oscillatory flow was developed to enhance blood-activator mixing. A computational fluid dynamic (CFD) model was established to investigate the microscale hydrodynamic characteristics and solid dispersion behavior in the oscillatory multiphase flow system. The numerical predictions were validated against tracer mixing experiments. Sample calculations for the air-liquid-solid flow system demonstrated that the initial loading position of activator particles significantly affected the dispersion efficiency due to the spatial variation in the radial velocity field. Compared with the center-initialized case, the solid dispersion level in the corner-initialized case decreased by approximately 42% after two oscillation cycles. Furthermore, the influence mechanism of oscillation period on solid dispersion was clarified through multi-physics coupling analysis. This study provided new insights into solid–liquid mixing in oscillatory microfluidic systems and established an effective CFD-based framework for optimizing microdevice design and operating conditions. Full article
(This article belongs to the Special Issue Fluid Flow in Microchannel)
Show Figures

Figure 1

21 pages, 6108 KB  
Article
Blood Flow Analysis and Structural Analysis of Arterial Wall in a 3D Model of the Carotid Artery Based on Magnetic Resonance Imaging
by Jonathan Rodolfo Guereca-Ibarra, Guillermo Urriolagoitia-Sosa, Beatriz Romero-Ángeles, Jacobo Martínez-Reyes, Jorge Alberto Gomez-Niebla, Edder Jair Rodríguez-Granados, Jonatan Mireles-Hernández, Miguel Martinez-Mondragon, Aldo Saul Laguna-Canales, David Sánchez-Hernández and Santiago Barrañón-Salmón
Fluids 2026, 11(7), 182; https://doi.org/10.3390/fluids11070182 - 20 Jul 2026
Viewed by 535
Abstract
The analysis of blood flow behavior has been studied in various aspects. Recently, these studies took a turn when they were developed using Computational Fluid Dynamics (CFD), thereby advancing understanding of fluid behavior. Artery geometries and the properties of flow offer a field [...] Read more.
The analysis of blood flow behavior has been studied in various aspects. Recently, these studies took a turn when they were developed using Computational Fluid Dynamics (CFD), thereby advancing understanding of fluid behavior. Artery geometries and the properties of flow offer a field of interest for developing studies in which the behavior of liquid and structures can be observed. Biomodel development has evolved to allow for greater ease and precision. With a geometry similar to the real one, mechanical properties can be used to conduct studies with greater precision, yielding greater results on the behavior of a fluid and a structure. This research focuses on developing a biomodel of the right carotid artery. CFD and structural analyses are performed using the generated arterial geometry and a control volume that simulates blood flow. The structural analysis was performed using the Finite Element Method (FEM) to obtain results that provide data on the effects on the arterial walls. The results presented focus on the velocity, pressure, and wall shear stress generated by the flow. In addition, a section on displacement and Von Mises stress results is presented, demonstrating how the structure of the arterial walls is affected by these effects. Full article
Show Figures

Figure 1

11 pages, 1605 KB  
Article
Laser Speckle Orthogonal Contrast Imaging Calibration by Replicating Red Blood Cell Scattering Statistics with a Moving Reference Diffuser
by Xavier Orlik, Aurélien Plyer and Elise Colin
Photonics 2026, 13(7), 609; https://doi.org/10.3390/photonics13070609 - 25 Jun 2026
Viewed by 405
Abstract
Recent studies have proposed improving Laser Speckle Contrast Imaging (LSCI) by using polarimetric filtering to isolate multiply scattered photons from moving red blood cells (RBCs), an approach referred to as Laser Speckle Orthogonal Contrast Imaging (LSOCI). This reliance on multiple scattering enables the [...] Read more.
Recent studies have proposed improving Laser Speckle Contrast Imaging (LSCI) by using polarimetric filtering to isolate multiply scattered photons from moving red blood cells (RBCs), an approach referred to as Laser Speckle Orthogonal Contrast Imaging (LSOCI). This reliance on multiple scattering enables the development of a calibration method based on a moving reference sample, chosen to generate dynamic circular Gaussian speckle fields that replicate the statistical properties of RBC scattering in both intensity and the distribution of polarization states. Assuming that multiply scattered photons from both RBCs and the reference sample exhibit a homogeneous distribution of polarization states over the Poincaré sphere, the proposed calibration links in vivo speckle contrast reduction bijectively to an equivalent speed of the reference sample. We demonstrate that this equivalent-velocity metric yields consistent in vivo measurements across distinct instruments despite the use of different laser spectral widths, thereby providing a standardized and transferable means to quantify microcirculatory activity. Full article
(This article belongs to the Special Issue Recent Progress in Biomedical Optical Technologies)
Show Figures

Figure 1

36 pages, 2442 KB  
Article
Simulation of Fe3O4 Nanoparticle Transport in a Diseased Curved Artery Under Thermal Influence: Implications for Targeted Drug Delivery
by Poonam, Bhupendra K. Sharma, Rishu Gandhi and David Laroze
Nanomaterials 2026, 16(11), 677; https://doi.org/10.3390/nano16110677 - 28 May 2026
Viewed by 932
Abstract
This study examines non-Newtonian electromagnetohydrodynamic (EMHD) blood flow via a diseased curved artery with minor stenosis and an aneurysm, adding a no-slip boundary condition, using targeted medication delivery of nanoparticles. The non-Newtonian behavior of blood flow is accounted for by the Casson fluid [...] Read more.
This study examines non-Newtonian electromagnetohydrodynamic (EMHD) blood flow via a diseased curved artery with minor stenosis and an aneurysm, adding a no-slip boundary condition, using targeted medication delivery of nanoparticles. The non-Newtonian behavior of blood flow is accounted for by the Casson fluid model. Using Corcione’s model, we have calculated the effective viscosity and thermal conductivity of nanofluids. The interaction of the nanofluid with physical phenomena such as viscous dissipation, electro-osmosis, radially applied uniform magnetic field and Joule heating can change the hemodynamic parameters of the fluid. The Crank–Nicolson approach has been used to calculate the velocity, temperature, and concentration patterns within the Debye–Huckel linearization approximation. Streamlines are delineated to analyze flow patterns across distinct physical factors. This study supports the design of magnetically guided Fe3O4 nanoparticle–based targeted drug delivery systems for treating vascular diseases such as stenosis and aneurysm, improving site-specific therapeutic efficiency. The numerical insights into thermal effects and arterial geometry help to optimize nanoparticle transport, enhancing treatment precision while minimizing systemic side effects. Full article
(This article belongs to the Section Biology and Medicines)
Show Figures

Figure 1

11 pages, 1236 KB  
Article
Radial Peripapillary Capillary Density Involved in Nasal Optic Disc Thinning and Visual Field Abnormalities Using Optical Coherence Tomography Angiography
by Miki Yoshimura, Yuki Hashimoto, Yuko Kodama, Aris Hatanaka, Ryusei Yakushiji, Shiho Ikeda, Nazuna Inoue, Maho Wakabayashi, Ichika Kawazu and Takeshi Yoshitomi
Tomography 2026, 12(5), 73; https://doi.org/10.3390/tomography12050073 - 15 May 2026
Viewed by 736
Abstract
Objectives: This study investigated whether visual field abnormalities are present in eyes with suspected nasal optic disc hypoplasia (NOH) by using fundus photography and optical coherence tomography (OCT). Methods: NOH was diagnosed using the following criteria: (1) small optic disc, (2) nasal optic [...] Read more.
Objectives: This study investigated whether visual field abnormalities are present in eyes with suspected nasal optic disc hypoplasia (NOH) by using fundus photography and optical coherence tomography (OCT). Methods: NOH was diagnosed using the following criteria: (1) small optic disc, (2) nasal optic disc pallor or optic disc margin irregularity, (3) wedge-shaped temporal visual field defects extending from Mariotte’s blind spot, and (4) reduced nasal circumpapillary retinal nerve fiber layer (cpRNFL) thickness. Eyes fulfilling criteria 1, 2, and 4 without visual field abnormalities were classified as pseudo-NOH (pNOH), whereas eyes without visual field or cpRNFL abnormalities were considered normal. Nasal cpRNFL thickness was measured using OCT, radial peripapillary capillary (RPC) density was assessed using OCT angiography (OCTA), visual field testing was performed, and optic disc blood flow velocity was evaluated using the mean blur rate (MBR) and laser speckle flowgraphy (LSFG). Results: Seven eyes with NOH, 13 eyes with pNOH, and 24 normal right eyes were included. Nasal cpRNFL thickness and MBR were significantly reduced in both the NOH and pNOH groups compared with the normal group, with no significant difference between the NOH and pNOH groups. Nasal RPC density was significantly lower in the NOH group than in both the pNOH and normal groups, and no significant difference was observed between the pNOH and normal groups. Conclusions: Even when NOH was suspected from fundus, LSFG, and OCT C-scan findings, visual field abnormalities were not consistently present. Differences in RPC density measured using OCTA may have contributed to this variability. This study examined whether suspected nasal optic disc hypoplasia (NOH) is always associated with visual field defects. Using fundus imaging, OCT, OCT angiography, and laser speckle flowgraphy, we compared eyes with NOH, pseudo-NOH, and normal eyes. Although structural changes such as reduced nasal nerve fiber layer thickness and decreased blood flow were observed in both NOH and pseudo-NOH, visual field abnormalities were not consistently present. Notably, reduced radial peripapillary capillary density was specific to NOH, suggesting that vascular differences may explain variability in visual function. These findings highlight the importance of multimodal imaging in NOH evaluation. Full article
Show Figures

Figure 1

22 pages, 2972 KB  
Article
Innovative Approximate Solution for Jerk Model of Non-Newtonian Bio-Nanofluid in Fractal Space via Highly Efficient Linear Approximation
by Nasser S. Elgazery and Taghreed H. Al-Arabi
Fractal Fract. 2026, 10(4), 255; https://doi.org/10.3390/fractalfract10040255 - 13 Apr 2026
Viewed by 571
Abstract
In this article, we present a new approximate solution for blood nanofluid having gold nanoparticles as it flows near a stretching porous cylinder in fractal space. A Casson non-Newtonian magneto-bio-nanofluid flowing through a porous medium is considered a potential application in chemotherapy for [...] Read more.
In this article, we present a new approximate solution for blood nanofluid having gold nanoparticles as it flows near a stretching porous cylinder in fractal space. A Casson non-Newtonian magneto-bio-nanofluid flowing through a porous medium is considered a potential application in chemotherapy for eradicating cancer cells. Without the need for the nonperturbative approach, the proposed solution uses an alternative approach to dealing with nonlinear problems. This approach transforms the nonlinear cubic jerk model resulting from the simplification of the governing fractional partial differential equations into an equivalent linear formula. This approach is known as highly efficient linear approximation (HELA) or non-perturbation technique (NPT), and this represents a significant advancement over traditional perturbation methods in the analysis of non-linear systems. As a robust mathematical approach, it excels at handling a wide range of coefficient values, particularly in cases of clear nonlinearity. This study also utilized the masking technique simultaneously with HELA, which played a crucial role, as they simplify the complex dynamics of the system, making it more amenable to analysis. The numerical solution by the Runge–Kutta fourth-order (RK-4) method integrated with a shooting technique compared favorably with graphs drawn for the analytical solution from the proposed strategy HELA. The current results show that an increase in the fractal factors enhances the resistance to fluid motion, leading to a suppression of the velocity field. Physically, this often relates to the complexity of the medium or the fractal nature of the transport process, where higher fractal dimensions or factors can lead to slower diffusion or flow rates, like the role of porous media. Therefore, the current study has significant implications in the promotion of nanotechnology fields in medicine, particularly the use of gold nanoparticles in chemotherapy for the eradication of cancerous cells. Full article
(This article belongs to the Section Mathematical Physics)
Show Figures

Figure 1

20 pages, 12202 KB  
Article
Computational Assessment of Shear Stress-Driven Flow Alterations at the Renal Artery Origin Under Varying Pressure Conditions
by Gowrava Shenoy Beloor, Raghuvir Pai Ballambat, Kevin Amith Mathias, Mohammad Zuber, Manjunath Mallashetty Shivamallaiah, Ravindra Prabhu Attur, Dharshan Rangaswamy, Prakashini Koteshwar, Masaaki Tamagawa and Shah Mohammed Abdul Khader
Computation 2026, 14(4), 85; https://doi.org/10.3390/computation14040085 - 3 Apr 2026
Viewed by 1277
Abstract
The use of computational fluid dynamics (CFD) to study hemodynamics in arteries offers significant potential for addressing complex flow problems. Due to its enhanced performance hardware and software, CFD has become an important approach for studying hemodynamics in human arteries. This approach is [...] Read more.
The use of computational fluid dynamics (CFD) to study hemodynamics in arteries offers significant potential for addressing complex flow problems. Due to its enhanced performance hardware and software, CFD has become an important approach for studying hemodynamics in human arteries. This approach is utilized to investigate hemodynamics and forecast risk factors for atherosclerotic lesion development and progression, including circulatory flow, and to analyze local flow fields and flow profiles resulting from geometric changes. This foundational study will aid in analyzing blood flow behavior through the abdominal aorta and the origin and courses of renal arteries, as well as investigating the causes of disorders such as atherosclerosis and hypertension. The current study investigates three idealized abdominal aorta–renal artery junction models under varying blood pressure settings. Materialise software V19 was used to extract the geometry data to create idealized 3D abdominal aorta–renal branching models. Unsteady flow simulations were performed in ANSYS Fluent, utilizing rigid walls and Newtonian and Carreau–Yasuda viscosity conditions. Oscillatory shear index (OSI) and Time-averaged wall shear stress (TAWSS) were measured to enhance understanding of atherosclerotic plaque formation and progression. Also, the effect of geometric change at the bifurcation area was explored, and it was discovered that this location causes considerable vortex forming zones. The evident velocity reduction and backflow development were seen, reducing shear stress. The findings indicate that low TAWSS < 0.4 Pa and OSI > 0.15 areas within the bifurcation region are more susceptible to atherosclerosis development. Full article
(This article belongs to the Section Computational Engineering)
Show Figures

Figure 1

27 pages, 4244 KB  
Article
Low-Voltage Blood Component Separation for Implantable Kidneys Using a Sawtooth Electrode and Negative Dielectrophoresis
by Hasan Mhd Nazha, Mhd Ayham Darwich, Al-Hasan Ali and Basem Ammar
Appl. Sci. 2026, 16(6), 2785; https://doi.org/10.3390/app16062785 - 13 Mar 2026
Viewed by 671
Abstract
Implantable artificial kidneys represent a promising alternative for patients with end-stage renal disease (ESRD), aiming to overcome the limitations of conventional dialysis through the integration of microfluidic and electrokinetic technologies. In this study, we present a sawtooth electrode microfluidic chamber that achieves blood [...] Read more.
Implantable artificial kidneys represent a promising alternative for patients with end-stage renal disease (ESRD), aiming to overcome the limitations of conventional dialysis through the integration of microfluidic and electrokinetic technologies. In this study, we present a sawtooth electrode microfluidic chamber that achieves blood cell separation via negative dielectrophoresis at a record-low operating voltage of 1.4 V, representing a fivefold reduction compared with rectangular electrode designs and supporting potential integration into implantable artificial kidney systems. A microfluidic chip incorporating an asymmetric sawtooth electrode geometry was developed to enhance local electric field gradients while reducing power consumption. Device performance was investigated using COMSOL Multiphysics simulations. Response Surface Methodology (RSM) based on a Box–Behnken design was employed to optimize the number of teeth per unit length (N), sawtooth height (H), and applied voltage (V), while excitation frequency was fixed at 1 MHz and flow velocity was maintained constant at 0.1 µL·min−1. Statistical analysis was conducted using analysis of variance (ANOVA) in Minitab (Version 27; Minitab, LLC, State College, PA, USA, 2024). The optimization model showed strong predictive capability (R2 = 95.8%) and identified applied voltage (59.45% contribution) and sawtooth height (33%) as the dominant factors affecting separation efficiency, with a significant H × V interaction (p = 0.023). Comprehensive voltage-response mapping over the range of 0.8–4.0 V revealed four operational regimes, including a previously unreported high-voltage failure zone above 2.8 V, where electrothermal flow and electroporation degrade performance. Under physiological conductivity conditions, the optimized design maintained a separation efficiency of 78.3% at 1.4 V with a tip temperature rise of only 1.2 °C, while full recovery of performance was achieved at 2.2 V. Cell-specific separation efficiencies reached 97.3% for white blood cells, 95.8% for red blood cells, and 84.7% for platelets, reducing the downstream cellular load by 92.6%. These findings demonstrate that the proposed low-voltage, high-efficiency separation platform has strong potential as a cellular pre-filtration module in implantable artificial kidney systems and other lab-on-chip biomedical devices. Full article
(This article belongs to the Special Issue Advances in Materials for Biosensing and Biomedical Applications)
Show Figures

Figure 1

33 pages, 9958 KB  
Article
Micro Blood Flow-Resolved Rheometry
by Yang Jun Kang
Micromachines 2026, 17(3), 331; https://doi.org/10.3390/mi17030331 - 6 Mar 2026
Cited by 1 | Viewed by 922
Abstract
For effectively assessing blood, red blood cell (RBC) aggregation and blood viscosity have been measured in microfluidic environments. However, the previous methods still face several challenges (dead-volume loss, RBC sedimentation, hematocrit-sensitive blood velocity, and precise flow rate control). In this study, a novel [...] Read more.
For effectively assessing blood, red blood cell (RBC) aggregation and blood viscosity have been measured in microfluidic environments. However, the previous methods still face several challenges (dead-volume loss, RBC sedimentation, hematocrit-sensitive blood velocity, and precise flow rate control). In this study, a novel method is suggested to resolve several issues. Air cavity (Vair = 250 μL) is secured above the blood column (at least 100 μL) loaded into a driving syringe. To probe RBC aggregation and blood viscosity, a microfluidic chip consists of a main channel (γ˙ > 1000 s−1) and an aggregation channel (γ˙ < 50 s−1). Blood is supplied into a microfluidic chip with two-step blood delivery (i.e., air compression for RBC aggregation, and syringe pump for blood viscosity). RBC aggregation index and blood viscosity are obtained from time-lapse image intensity and blood flow rate in both channels. As performance demonstrations, first, the measurement accuracy of fluid viscosity is validated with glycerin solution. Then, the present method is adopted to probe the difference in hematocrit and dextran concentration. At last, the proposed method is employed to detect heat-shocked RBCs (45~50 °C for 40 min). In conclusion, the proposed method has the ability to accurately measure substantial changes in RBCs or blood medium. Full article
Show Figures

Figure 1

21 pages, 4694 KB  
Article
Fourier-Feature Neural Surrogate for Hemodynamic Field Reconstruction in Stenotic and Bifurcating Flows
by Polydoros N. Papadopoulos and Vasilis N. Burganos
Mach. Learn. Knowl. Extr. 2026, 8(3), 59; https://doi.org/10.3390/make8030059 - 3 Mar 2026
Viewed by 1203
Abstract
This work presents a fast neural surrogate capable of reconstructing fully three-dimensional hemodynamic velocity fields in stenotic and bifurcating microvascular geometries with satisfactory accuracy, avoiding repeated, computationally demanding computational fluid dynamics (CFD) simulations. A Fourier-augmented, coordinate-neural surrogate is presented and assessed for rapid [...] Read more.
This work presents a fast neural surrogate capable of reconstructing fully three-dimensional hemodynamic velocity fields in stenotic and bifurcating microvascular geometries with satisfactory accuracy, avoiding repeated, computationally demanding computational fluid dynamics (CFD) simulations. A Fourier-augmented, coordinate-neural surrogate is presented and assessed for rapid computation of three-dimensional blood-flow fields in a sample geometry. The model is trained on detailed CFD data across a parameter set of stenosis severities that feed a direct mapping from spatial coordinates to velocity components. To mitigate spectral bias and improve accuracy in regions of steep gradients, the input space is embedded with random Fourier features and compared against a conventional multilayer perceptron (MLP) backbone. Predictive ability is assessed upon strict hold-out testing, during which certain arteriolar stenosis cases are excluded from training and treated with the Fourier surrogate. Direct comparison with CFD results reveals that the Fourier MLP achieves nearly CFD fidelity with the coefficient of determination R2 ≥ 0.994 and offers more than 80% reduction in the normalized errors as provided by conventional MLP, with the precise improvement depending on the severity of stenosis. Centerline velocity and cross-sectional profiles further show that the Fourier MLP reconstructs stenosis speed-up and radial profiles more reliably compared to conventional MLP. These results indicate that Fourier feature embedding provides a simple and effective route to robust full-field hemodynamic surrogates for efficient screening of stenosis configurations without resorting to repeated, heavily demanding CFD simulations. Full article
Show Figures

Graphical abstract

26 pages, 2773 KB  
Article
Penta-Hybrid Nanofluid Transport and Irreversibility in Stenotic Arteries Under Caputo–Fabrizio Fractional Dynamics
by Basim M. Makhdoum
Eng 2026, 7(2), 78; https://doi.org/10.3390/eng7020078 - 10 Feb 2026
Cited by 1 | Viewed by 1021
Abstract
The current research first investigates the flow in the fractional order of a vertical artery with atherosclerosis using a Casson-based penta-hybrid nanofluid. Gold (Au), copper (Cu), silver (Ag), magnesium oxide (MgO), and alumina (Al2O3) nanoparticles are dispersed in blood [...] Read more.
The current research first investigates the flow in the fractional order of a vertical artery with atherosclerosis using a Casson-based penta-hybrid nanofluid. Gold (Au), copper (Cu), silver (Ag), magnesium oxide (MgO), and alumina (Al2O3) nanoparticles are dispersed in blood to make the hybrid nanofluid. It is assumed that the flow is very pulsatile. The mathematical model is constructed by using differential forms of the conservation laws of mass, momentum, energy, and irreversibility analysis. By applying the mild stenosis approximation, the governing equations are transformed into dimensionless form. To generalize the classical model to its fractional counterpart, the Caputo–Fabrizio fractional derivative (C-FFD) is employed. Closed-form solutions for the velocity and temperature fields are realized by the joint application of the Laplace and Hankel transforms. The impact of essential physical parameters on velocity, temperature, and entropy generation is displayed through figures. The physical significance of enhanced thermal characteristics is shown, emphasizing their potential relevance to thermal regulation, targeted drug delivery, and minimization of irreversible energy losses in biomedical flow systems. The velocity profile elevates with the increase in the Casson parameter, while the temperature drops as the fractional-order parameter rises. Entropy generation is observed to amplify with the increasing values of the thermodynamic parameter in question, whereas an opposite tendency is seen for the Bejan number. The Bejan number decreases as the control parameter becomes higher. The novelty of the present investigation lies in the simultaneous incorporation of Caputo–Fabrizio fractional dynamics, penta-hybrid nanoparticle suspension, and entropy generation analysis in a stenosed arterial configuration. Unlike existing fractional Casson blood flow models that primarily focus on single or hybrid nanofluids, the present framework highlights the synergistic enhancement of thermal transport and irreversibility control achieved through penta-hybrid nanoparticles, which may be relevant for advanced biomedical and targeted therapeutic applications. Full article
Show Figures

Figure 1

17 pages, 2934 KB  
Article
A Microfluidic Platform for Viscosity Testing of Non-Newtonian Fluids in Engineering and Biomedical Applications
by Yii-Nuoh Chang and Da-Jeng Yao
Micromachines 2026, 17(2), 201; https://doi.org/10.3390/mi17020201 - 1 Feb 2026
Cited by 1 | Viewed by 1666
Abstract
This study presents a microfluidic platform for non-Newtonian fluid viscosity sensing, integrating a high-flow-rate flow field stabilizer to mitigate flow uniformity limitations under elevated flow rate conditions. Building upon an established dual-phase laminar flow principle that determines relative viscosity via channel occupancy, this [...] Read more.
This study presents a microfluidic platform for non-Newtonian fluid viscosity sensing, integrating a high-flow-rate flow field stabilizer to mitigate flow uniformity limitations under elevated flow rate conditions. Building upon an established dual-phase laminar flow principle that determines relative viscosity via channel occupancy, this research aimed to extend the measurable viscosity range from 1–10 cP to 1–50 cP, which covers viscosity regimes relevant to biomedical fluids, dairy products during gelation, and low-to-moderate viscosity industrial liquids. A flow stabilizer was developed through computational fluid dynamics simulations, optimizing three key design parameters: blocker position, porosity, and the number of outlet paths. The N5 design proved most effective, providing over 50% reduction in standard deviation for asymmetric velocity distribution in high-flow simulations. The system was validated using simulated blood and dairy samples, achieving over 95% viscosity accuracy with less than 5% sample volume error compared to conventional viscometers. The chip successfully captured viscosity transitions during milk acidification and gelation, demonstrating excellent agreement with standard measurements. This low-volume, high-precision platform offers promising potential for applications in food engineering, biomedical diagnostics, and industrial fluid monitoring, enhancing microfluidic rheometry capabilities. Full article
(This article belongs to the Special Issue Microfluidics in Biomedical Research)
Show Figures

Figure 1

18 pages, 2843 KB  
Article
Feasibility of Golden Angle Spiral Real-Time Phase Contrast MRI at 0.55T: A Single-Center Prospective Study
by Salman Pervaiz, Chong Chen, Yingmin Liu, Katherine Binzel, Kelvin Chow, Rizwan Ahmad, Yuchi Han, Orlando P. Simonetti, Ning Jin and Juliet Varghese
Bioengineering 2026, 13(2), 166; https://doi.org/10.3390/bioengineering13020166 - 29 Jan 2026
Viewed by 1527
Abstract
Background: Real-time phase-contrast magnetic resonance (RT-PCMR) imaging allows free-breathing assessment of blood flow across cardiac valves and vessels. However, the feasibility of free-breathing RT-PCMR on a mid-field (0.55T) MRI system has yet to be established. Aim: The primary objective of this study [...] Read more.
Background: Real-time phase-contrast magnetic resonance (RT-PCMR) imaging allows free-breathing assessment of blood flow across cardiac valves and vessels. However, the feasibility of free-breathing RT-PCMR on a mid-field (0.55T) MRI system has yet to be established. Aim: The primary objective of this study was to implement a RT-PCMR sequence using a dual-density golden-angle spiral readout with SENSE-based compressed sensing (CS) reconstruction on a 0.55T MRI system. The secondary objective was to evaluate the feasibility of this approach in an adult cohort comprising healthy volunteers and patients with cardiovascular disease. Materials and Methods: Data from 33 participants were included in the flow quantification analysis (healthy volunteers: n = 17, 9 females, mean age 30.4 ± 14.6 years; patients: n = 16, 11 females, mean age 45.9 ± 17.4 years), with breath-held (BH) segmented Cartesian PCMR used as the reference standard. Results: In volunteers, RT-PCMR showed good agreement for net flow, peak flow rate, and pulmonary–systemic flow ratio (Qp/Qs), without significant bias (p > 0.05) and slightly underestimated peak velocity [7.9% in the aorta and 8.6% in the main pulmonary artery (MPA)]. In patients, RT-PCMR slightly underestimated peak flow rate (aorta, 6.2%; MPA; 4.6%) and peak velocity (aorta,12.7%; MPA, 10.4%). A sub-analysis of six patients scanned at both 0.55T and 3T showed close agreement between field strengths. Conclusions: These results demonstrate the feasibility of our RT-PCMR sequence on a commercial 0.55T system. Full article
(This article belongs to the Special Issue Recent Advances in Cardiac MRI)
Show Figures

Graphical abstract

19 pages, 3290 KB  
Article
Magnetically Sculpted Microfluidics for Continuous-Flow Fractionation of Cell Populations by EpCAM Expression Level
by Zhenwei Liang, Xiaolei Guo, Xuanhe Zhang, Yiqing Chen, Chuan Du, Yuan Ma and Jiadao Wang
Micromachines 2026, 17(1), 9; https://doi.org/10.3390/mi17010009 - 22 Dec 2025
Cited by 1 | Viewed by 987
Abstract
Continuous-flow separation of magnetically labeled cells according to surface-marker expression levels is increasingly needed to study phenotypic heterogeneity and support downstream assays. Here, we present a microfluidic platform that uses spatially engineered soft magnetic strips (SMS) to sculpt lateral magnetic deflection fields for [...] Read more.
Continuous-flow separation of magnetically labeled cells according to surface-marker expression levels is increasingly needed to study phenotypic heterogeneity and support downstream assays. Here, we present a microfluidic platform that uses spatially engineered soft magnetic strips (SMS) to sculpt lateral magnetic deflection fields for quantitative, label-guided cell fractionation. Under a uniform bias field, the SMS generates controllable magnetic gradients within the microchannel, producing distinct lateral velocities among EpCAM-labeled tumor cells that carry different Dynabead loads, which indirectly report membrane protein expression. Multi-outlet collection converts these “race-based” trajectory differences into discrete expression-level-resolved fractions. A COMSOL–MATLAB framework and a force-equivalent metric |(H·∇)H| are used to optimize key structural parameters of the magnetic interface, including strip thickness, width, and vertical spacing from the flow channel. Three journey nodes at 1.5, 3, and 9 mm along the flow path define a three-stage cascade that partitions MDA-MB-231, Caco-2, and A549 cells into four EpCAM-related magnetic subgroups: high (H), medium (M), low (L), and near-negative (N). Experiments show that the sorted fractions follow the expected expression trends reported in the literature, while maintaining high cell recovery (>90%) and viability retention of 98.2 ± 1.3%, indicating compatibility with downstream whole-blood assays and culture. Rather than introducing a new biomarker, this work establishes a quantitative magnetic-field design strategy for continuous microfluidic sorting, in which the spatial configuration of soft magnetic elements is exploited to implement expression-level-dependent fractionation in next-generation magneto-fluidic separation systems. Full article
(This article belongs to the Special Issue Microfluidic Chips for Biomedical Applications)
Show Figures

Figure 1

30 pages, 2551 KB  
Article
Magnetohydrodynamic Flow and Transport Behaviors of Blood-Based Ternary Nanofluids in Stenosed Arteries with Axial Symmetry: Effects of Thermal Radiation and Caputo Fractional Derivatives
by Ji-Huan He, Magaji Yunbunga Adamu, Isah Abdullahi, Nuo Xu and Chun-Hui He
Symmetry 2025, 17(12), 2024; https://doi.org/10.3390/sym17122024 - 25 Nov 2025
Cited by 7 | Viewed by 1177
Abstract
The present study investigates the magnetohydrodynamic (MHD) flow characteristics of a blood-based ternary nanofluid (Au/Cu/Al2O3-blood) in stenosed arteries, with a focus on symmetry-inspired modeling rooted in the axial symmetry of arterial geometry and the symmetric distribution of external physical [...] Read more.
The present study investigates the magnetohydrodynamic (MHD) flow characteristics of a blood-based ternary nanofluid (Au/Cu/Al2O3-blood) in stenosed arteries, with a focus on symmetry-inspired modeling rooted in the axial symmetry of arterial geometry and the symmetric distribution of external physical fields (magnetic field, thermal radiation). The findings offer significant insights into the realm of hyperthermia therapy and targeted drug delivery within the domain of biomedical engineering. A mathematical model is established under a cylindrical coordinate system (consistent with arterial axial symmetry), integrating key physical effects (thermal radiation, chemical reactions, viscous dissipation, body acceleration) and fractional-order dynamics via Caputo derivatives—while ensuring the symmetry of governing equations in time and space. The numerical solutions for velocity and temperature profiles are obtained using the Laplace transform and Concentrated Matrix-Exponential (CME) method, a technique that preserves symmetric properties during the solution process. The results of the study indicate the following: The Hartmann number, which is increased, has been shown to reduce axial velocity due to the Lorentz force, thereby maintaining radial symmetry. Furthermore, thermal radiation has been demonstrated to raise fluid temperature, a critical factor in heat-based therapies, with the temperature field evolving symmetrically. In addition, it has been observed that ternary nanoparticles outperform single and binary systems in heat and mass transfer via symmetric dispersion. This work contributes to the existing body of knowledge by integrating symmetry principles into the study of fractional dynamics, electromagnetic fields, and body acceleration modeling. It establishes a comprehensive biomedical flow framework. It is imperative that future research explore pulsatile flow under symmetric boundaries and validate the model through experimental means. Full article
(This article belongs to the Section B: Mathematics)
Show Figures

Figure 1

Back to TopTop