Next Issue
Volume 6, August
Previous Issue
Volume 6, April
 
 

Constr. Mater., Volume 6, Issue 3 (June 2026) – 14 articles

Cover Story (view full-size image): This study focuses on blistering between a concrete substrate and a resin coating. The hypothesis is that the cementitious material and the overlying reactive resin coating form a system that may lead to damage under certain boundary conditions related to material composition, moisture, and mass transport. Systematic investigations were carried out in an extensive testing program using various substrate mortars differing in cement type, water–cement ratio, and aggregate composition. As coating systems, two different EP primers were used together with a transparent EP topcoat. Long-term testing focused on potential blistering of composite test specimens stored under various (practically relevant) conditions before and after coating. View this paper
  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list.
  • You may sign up for e-mail alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.
Order results
Result details
Select all
Export citation of selected articles as:
35 pages, 3117 KB  
Article
Evaluating the Impact of Nano-Zeolite and Lime on Reconstituted Soil Resistance Using Explainable Machine Learning Framework
by Paula Abdo-Peralta, Nestor Ulloa, Evelin Rosero, Kerly Mishell Vaca Vallejo, Mauricio Chavez and Christian Rolando Zapata León
Constr. Mater. 2026, 6(3), 37; https://doi.org/10.3390/constrmater6030037 - 15 Jun 2026
Viewed by 777
Abstract
This study investigates the effect of nano-zeolite and lime on the resistance of reconstituted soil using an integrated experimental and explainable machine learning framework. Soil samples were prepared with varying proportions of nano-zeolite, lime, and fines, and cured under controlled temperature and time [...] Read more.
This study investigates the effect of nano-zeolite and lime on the resistance of reconstituted soil using an integrated experimental and explainable machine learning framework. Soil samples were prepared with varying proportions of nano-zeolite, lime, and fines, and cured under controlled temperature and time conditions. Soil resistance (q) was measured to evaluate the mechanical performance of each mixture. Eight machine learning models, including artificial neural networks (ANN), random forest (RF), random tree (RT), random committee–random tree (RC-RT), M5Rules, KStar, RBFS, and additive regression–decision stump (AR-DS), were developed using Weka 3.8.6 to predict soil resistance based on the input parameters. Model performance was assessed using SSE, MAE, MSE, RMSE, Error %, Accuracy %, R2, correlation coefficient, Willmott Index, Nash–Sutcliffe Efficiency, Kling–Gupta Efficiency, and SMAPE. ANN and RF achieved superior accuracy (R2 ≥ 0.98) with minimal prediction error, effectively capturing the nonlinear interactions between stabilizer content, curing time, and environmental conditions. Sensitivity analyses using the analysis index and SHAP values revealed that nano-zeolite, lime, and curing time were the dominant factors influencing soil resistance, while fines content and curing temperature had secondary effects. The results demonstrate that nano-zeolite and lime significantly enhance soil resistance and that explainable machine learning models can reliably predict and interpret soil performance, providing a data-driven framework for optimized soil stabilization in geotechnical engineering applications. Full article
(This article belongs to the Special Issue Mineral and Metal Materials in Civil Engineering)
Show Figures

Figure 1

37 pages, 77606 KB  
Article
Experimental Investigation of Hexagonal and Square Textile-Reinforced Cementitious Composite Elements and Their Connecting Systems
by Aras Arslan, Mustafa Gencoglu and Arastoo Khajehdehi
Constr. Mater. 2026, 6(3), 36; https://doi.org/10.3390/constrmater6030036 - 3 Jun 2026
Viewed by 715
Abstract
This study experimentally investigates the structural behavior of hexagonal- and square-shaped composite specimens subjected to vertical compression, vertical tension, and diagonal tension loading. The specimens were fabricated using four- and six-layer alkali-resistant (AR) glass textile reinforcements embedded in a modified cementitious mortar via [...] Read more.
This study experimentally investigates the structural behavior of hexagonal- and square-shaped composite specimens subjected to vertical compression, vertical tension, and diagonal tension loading. The specimens were fabricated using four- and six-layer alkali-resistant (AR) glass textile reinforcements embedded in a modified cementitious mortar via pull, pour, and roll manufacturing techniques. The mechanical performance of polyvinyl alcohol (PVA) fiber-reinforced composite connectors and steel clamp-type elements was also evaluated at the joints of hexagonal specimens under vertical tension and lateral shear loading. The results show that increasing the number of textile layers significantly enhances structural performance. A 50% increase in textile layers improved load-carrying capacity by up to 56% in compression, 104% in tension, and 216% in diagonal tension. Corresponding increases of approximately 20–42% in ductility and up to 266% in energy dissipation capacity were observed. No failure occurred in the connecting elements, confirming their adequate stiffness, strength, and ductility. In addition, validated three-dimensional finite element models were developed to simulate the response of the hexagonal specimens. Overall, the proposed system demonstrates strong potential for applications such as infill walls, cladding, and sandwich panels due to its favorable strength, ductility, and energy absorption capacity. Full article
Show Figures

Figure 1

14 pages, 1748 KB  
Article
Shannon Entropy of Corrected AE Data for Damage Assessment in CFRP-Strengthened RC Beams: From Brittle Shear to Distributed Failure
by Sena Tayfur and Ninel Alver
Constr. Mater. 2026, 6(3), 35; https://doi.org/10.3390/constrmater6030035 - 3 Jun 2026
Viewed by 411
Abstract
The abrupt failure of shear-deficient RC beams may lead to harmful consequences under dynamic loading. The use of Carbon Fiber Reinforced Polymers (CFRP) aims to convert this brittle fracture into a ductile one. However, the complexity of the multiple damage mechanisms makes it [...] Read more.
The abrupt failure of shear-deficient RC beams may lead to harmful consequences under dynamic loading. The use of Carbon Fiber Reinforced Polymers (CFRP) aims to convert this brittle fracture into a ductile one. However, the complexity of the multiple damage mechanisms makes it difficult to assess their condition using conventional testing methods. In this study, the damage evolution of a shear-critical reference beam and its CFRP-strengthened counterpart was monitored using the acoustic emission (AE) technique. After correcting attenuated AE amplitudes, damage analysis was performed using the Shannon entropy approach based on true source amplitudes. The entropy analysis performed with these corrected data clearly revealed the shear failure in the reference beam through abrupt drops in entropy, indicating damage homogenization. In contrast, the entropy remaining high and dynamically varying over a much longer deflection range in the CFRP-strengthened beam demonstrated that CFRP distributes damage over a wider region and that different damage mechanisms, such as debonding and fiber breakage, in addition to concrete cracking, were simultaneously active. Full article
Show Figures

Figure 1

28 pages, 6587 KB  
Article
Synergistic Effects of Multi-Walled Carbon Nanotubes and SBS on Asphalt Binder Performance
by Amjad H. Albayati, Hasan M. Al-Mosawe, Ahmed M. Mohammed, Mayank Sukhija, Aliaa F. Al-ani, Mazen J. Al-Kheetan and Mustafa M. Moudhafar
Constr. Mater. 2026, 6(3), 34; https://doi.org/10.3390/constrmater6030034 - 29 May 2026
Viewed by 577
Abstract
The performance and durability of asphalt pavements are strongly influenced by the rheological properties of asphalt binders, particularly under severe climatic and traffic conditions. This study investigates the synergistic effects of incorporating multi-walled carbon nanotubes (CNTs) at dosages ranging from 0.25% to 1% [...] Read more.
The performance and durability of asphalt pavements are strongly influenced by the rheological properties of asphalt binders, particularly under severe climatic and traffic conditions. This study investigates the synergistic effects of incorporating multi-walled carbon nanotubes (CNTs) at dosages ranging from 0.25% to 1% into AC 40-50 asphalt binders modified with 4% Styrene–Butadiene–Styrene (SBS). A comprehensive experimental program involving physical, rheological, and chemical characterization tests was conducted, including penetration, softening point, viscosity, storage stability, a Dynamic Shear Rheometer (DSR), Multiple Stress Creep Recovery (MSCR), Linear Amplitude Sweep (LAS), Fourier Transform Infrared Spectroscopy (FTIR), and Glover-Rowe (G-R) analysis. Statistical inference using one-way ANOVA was also conducted to evaluate the significance of differences among the binder formulations investigated. The results showed a continuous increase in binder stiffness with increasing CNT content, as indicated by decreasing penetration values, higher softening points, and increased viscosity. Incorporating 1% CNT reduced the softening-point difference from 3.1 °C to 1.6 °C in SBS-modified binders, indicating improved storage stability. Rheological evaluations showed that 0.75% CNT increased the high-temperature performance grade from 82 °C to 88 °C and provided the best rutting resistance, as indicated by MSCR results. In contrast, the 0.5% CNT formulation exhibited superior fatigue resistance and the lowest Glover-Rowe index, indicating improved cracking resistance and durability. Overall, the findings demonstrate that CNTs can effectively enhance the performance of SBS-modified asphalt binders, with 0.75% CNT being optimal for hot-climate applications, while 0.5% CNT exhibited improved fatigue and cracking resistance under moderate-temperature conditions. Full article
Show Figures

Figure 1

21 pages, 8945 KB  
Article
Influence of Curing Methods on Mechanical Properties of Concrete Beams Produced Through Additive Construction Methods
by Eric J. Faierson, Benjamin D. Nelson and Elizabeth S. Poblete
Constr. Mater. 2026, 6(3), 33; https://doi.org/10.3390/constrmater6030033 - 29 May 2026
Viewed by 496
Abstract
The integration of advanced additive manufacturing technologies, particularly 3D printing (3DP), also known as Additive Construction (AC), could influence a shift in the construction industry towards improved efficiency and automation. This research evaluated the effect on hardened properties of two different concrete mixes [...] Read more.
The integration of advanced additive manufacturing technologies, particularly 3D printing (3DP), also known as Additive Construction (AC), could influence a shift in the construction industry towards improved efficiency and automation. This research evaluated the effect on hardened properties of two different concrete mixes for use in 3DP based on the presence or absence of alkaline-resistant (AR) glass fibers. Furthermore, three different curing methods were evaluated: air-curing, plastic-covered curing, and spray-curing. Concrete beams were printed for flexural testing, and cores were taken from other depositions to evaluate compressive strength and split-tensile strength. An analysis of the size and location of cracks on the beams after curing was performed for the different mixes and curing methods. For beams without fibers, plastic-covered curing produced the highest flexural modulus values, and air-curing produced the lowest flexural modulus values. Plastic-cured beams with fibers had higher flexural modulus values than the air-cured beams with fibers. However, the spray-cured beams with fibers produced somewhat anomalous results, with one flexural modulus value being larger than those of the plastic-cured beams, and the other flexural modulus value being less than those of the air-cured beams. All 28-day compressive strengths and split-tensile strengths across mixes and curing conditions fell within a small band ranging between ~19.3–22.1 MPa and ~1.7–2.0 MPa (~2800–3200 psi, and 240–290 psi), respectively. There was a large amount of scatter in some of the tests. It appears that neither the presence of the AR-glass fibers, nor the type of curing had a large influence on compressive strength or split-tensile strength. Results showed that the addition of fibers and the use of the plastic during curing significantly reduced the occurrence, the width, and the depth of cracks as a result resulting from the curing process. Plastic-curing was the most effective curing method for minimizing the occurrence of cracks. Any cracks that formed during plastic-curing were extremely fine and had little or no effect on mechanical properties. Full article
Show Figures

Figure 1

22 pages, 4066 KB  
Review
Chemical and Microstructural Investigation of Concrete with Seawater and Sea Sand Towards Understanding Long-Term Performance: A Review
by Ali Alzahrani and Mithila Achintha
Constr. Mater. 2026, 6(3), 32; https://doi.org/10.3390/constrmater6030032 - 25 May 2026
Cited by 1 | Viewed by 1351
Abstract
Seawater and sea sand as constituents in concrete are valuable alternatives to freshwater and river sand. Further, the use of seawater and sea sand in projects located in the proximity of a sea/ocean can reduce the overall project cost and lower the carbon [...] Read more.
Seawater and sea sand as constituents in concrete are valuable alternatives to freshwater and river sand. Further, the use of seawater and sea sand in projects located in the proximity of a sea/ocean can reduce the overall project cost and lower the carbon footprint. Nevertheless, seawater contains high concentrations of chloride (Cl), sulphate (SO42−) and magnesium (Mg2+), which can react with tricalcium aluminate (C3A) in cement and the byproduct calcium hydroxide (Ca(OH)2), and form Friedel’s salt, delayed ettringite and brucite, respectively. These chemical compounds are aggressive and can degrade the strength and durability of the concrete. Differences in the physical properties of sea sand compared to river sand can also lead to weak and porous concrete. In reinforced concrete, steel bars are susceptible to corrosion due to the formation of corrosion products as a result of high concentrations of Cl. Whilst mitigation strategies such as the use of supplementary cementitious materials (SCMs) and fibre-reinforced polymer (FRP) reinforcements have been investigated in the literature, no validated method that enables the use of concrete with seawater and sea sand has been established. Based on research reported in the literature, the present study investigates the chemistry, strength and microstructure of concrete mixed with seawater and sea sand as a means of establishing their use in concrete without compromising the properties of the concrete. The study shows that the compressive strength of seawater–sea sand mixed concrete (SWSSC) is increased in the short term (up to 28 days) due to the formation of additional chemical compounds in the former. However, the long-term (i.e., beyond 28 days) compressive strength of concrete reduces by up to 20% after one year due to the weakening of the microstructure (more flaws/expansions), which further reduces the durability of the reinforced concrete. Although the long-term degradation of SWSSC has been noticed, the underlying causes are not fully understood. The present critical review study provides chemical and microstructural insight into the degradation of concrete with seawater and sea sand, and the current developing understanding is used to develop a mitigation strategy towards the use of seawater and sea sand in real-world concrete applications. Full article
Show Figures

Figure 1

21 pages, 2156 KB  
Article
Mass-Based Replacement of Natural Coarse Aggregate with Electric Arc Furnace Slag Aggregate in Ordinary Portland Cement Concrete
by Mohamad Ali-Ahmad, Christina El Sawda, Amenah AlFailakawi, Nourah AlKhaldi, Sarah AlMajed, Malak Sughayer and Nourah AlZuabi
Constr. Mater. 2026, 6(3), 31; https://doi.org/10.3390/constrmater6030031 - 22 May 2026
Cited by 1 | Viewed by 765
Abstract
This study investigates the effect of mass-based replacement of natural coarse aggregate with electric arc furnace (EAF) slag on the performance of ordinary Portland cement (OPC) concrete. Replacement levels of 0%, 30%, 50%, and 100% were examined, with particular attention to the volumetric [...] Read more.
This study investigates the effect of mass-based replacement of natural coarse aggregate with electric arc furnace (EAF) slag on the performance of ordinary Portland cement (OPC) concrete. Replacement levels of 0%, 30%, 50%, and 100% were examined, with particular attention to the volumetric changes induced by the higher density of EAF slag, which leads to an increase in paste volume. Fresh, mechanical, durability-related, and microstructural properties were evaluated. Results show a continuous reduction in workability with increasing slag content, despite the increase in paste volume, indicating the dominant influence of aggregate morphology on rheological behavior. Mechanical performance exhibited a non-linear response. Within the tested series, the 50% replacement mixture showed the highest mean compressive and splitting tensile strengths; however, the compressive strength difference relative to the control mixture remained small and within typical experimental scatter. In contrast, water absorption decreased progressively, reflecting improved matrix densification. However, this densification did not translate into enhanced mechanical performance, highlighting a decoupling between durability-related indicators and strength. A screening-level CO2 assessment further showed that reductions in aggregate-related emissions were offset by increased cement content associated with mass-based replacement. The results emphasize the importance of considering volumetric effects when interpreting the behavior and sustainability of slag-based concrete. Note: all strength comparisons are based on mean values from three-specimen sets without formal statistical testing and should be regarded as exploratory observations. Full article
Show Figures

Figure 1

29 pages, 5161 KB  
Article
Blistering of Reactive Resin Coatings on Concrete: New Insights
by Franziska Vogt and Andrea Osburg
Constr. Mater. 2026, 6(3), 30; https://doi.org/10.3390/constrmater6030030 - 19 May 2026
Viewed by 538
Abstract
The formation of blisters in reactive resin coatings on concrete is a widely known phenomenon that is also a subject of debate in the literature. In particular, blisters forming after curing of the coating can lead to extensive damage. This study was focused [...] Read more.
The formation of blisters in reactive resin coatings on concrete is a widely known phenomenon that is also a subject of debate in the literature. In particular, blisters forming after curing of the coating can lead to extensive damage. This study was focused on the investigation of blistering between the concrete substrate and the resin coating. The hypothesis is that the cementitious material and the overlying reactive resin coating form a system that leads to damage under certain boundary conditions regarding material composition, as well as moisture and mass transport. Systematic investigations were carried out in an extensive testing program with various substrate mortars that differ in cement type, water–cement ratio, and aggregate. As coating systems, two different EP primers were used with a transparent EP topcoat. The long-term testing was conducted on potential blistering of composite test specimens stored under various (practically relevant) conditions prior and after the coating. It was found that a higher moisture content of the substrate reduces blistering of the EP coating system. EP systems containing benzyl alcohol do not automatically tend to blister. Furthermore, condensation in the substrate provides sufficient amounts of water to cause blistering and ASR can contribute to blister formation. Full article
Show Figures

Figure 1

28 pages, 8585 KB  
Systematic Review
Increasing the Reuse Potential of Recycled Aggregates from Concrete and Masonry CDW: Treatment, Performance, and Sustainability for Structural Applications
by Nisal Dananjana Rajapaksha, Mehrdad Ameri Vamkani, Michaela Gkantou, Francesca Giuntini and Ana Bras
Constr. Mater. 2026, 6(3), 29; https://doi.org/10.3390/constrmater6030029 - 15 May 2026
Viewed by 1130
Abstract
Recycled aggregates (RAs) from construction and demolition waste (CDW) provide substantial circular-economy benefits, yet their elevated porosity, adhered mortar, and heterogeneity typically impair the mechanical performance and durability of recycled aggregate concrete (RAC). This PRISMA 2020-compliant systematic review synthesises 2180 records (2015–2026) to [...] Read more.
Recycled aggregates (RAs) from construction and demolition waste (CDW) provide substantial circular-economy benefits, yet their elevated porosity, adhered mortar, and heterogeneity typically impair the mechanical performance and durability of recycled aggregate concrete (RAC). This PRISMA 2020-compliant systematic review synthesises 2180 records (2015–2026) to evaluate advanced strategies for enhancing RA quality prior to structural use. This paper critically compares removal-based treatments (mechanical, thermal, acid cleaning) with strengthening and densification approaches, including accelerated carbonation, pozzolanic and nano-silica coatings, polymer impregnation, microbial-induced calcium carbonate precipitation (MICP), and modified mixing methods such as triple-stage mixing (TSMA). Evidence shows that while all RA types (including recycled fine aggregate (RFA), recycled coarse aggregate (RCA), and their combination (RFCA)) can slightly reduce compressive strength and 30% replacement serves as a critical threshold, beyond this, strength loss accelerates, particularly in RCA and RFCA mixes. However, accelerated carbonation and TSMA consistently refine the interfacial transition zone, reduce water absorption by 17–30%, and recover 85–94% of natural aggregate concrete strength. Bio-deposition reduces water absorption by 13–21%, while acid/silica fume treatments improve late-age strength but carry environmental trade-offs. This review formulates a practice-oriented implementation framework for structural-grade RAC. Sustainability analyses indicate that carbonated RA can achieve net-positive CO2 abatement when under low-carbon energy supply. A mechanistic schematic is presented to synthesise treatment-to-pore-structure/durability pathways across the four principal treatment routes, and a quantitative synthesis plot compares water absorption reductions across all treatment types using 13 data points drawn from included studies. A structured treatment comparison evaluates the energy intensity, industrial scalability, CO2 footprint, and technology readiness level for each strategy. The remaining challenges include a lack of hybrid treatment studies, limited real-scale durability data, and insufficient mechanistic models linking treatment to pore structure evolution. This review recommends harmonised durability-based criteria and updates to standards (e.g., BS 8500, EN 12620) to support the scalable deployment of treated RA. Full article
(This article belongs to the Topic Green Construction Materials and Construction Innovation)
Show Figures

Figure 1

25 pages, 5784 KB  
Article
Experimental Study on the Drying Shrinkage Behavior of Fiber-Reinforced Normal and High-Strength Concrete Under Different Ambient Conditions
by Tamim A. Samman, Khatib Zada Farhan and Md Ashraful Hossain
Constr. Mater. 2026, 6(3), 28; https://doi.org/10.3390/constrmater6030028 - 13 May 2026
Viewed by 859
Abstract
Drying shrinkage is a critical durability issue in concrete structures, particularly in high-strength concrete (HSC), which is more susceptible to early-age cracking due to its low water–cement ratio and dense microstructure. This study experimentally evaluates the restrained drying shrinkage behavior of fiber-reinforced concretes [...] Read more.
Drying shrinkage is a critical durability issue in concrete structures, particularly in high-strength concrete (HSC), which is more susceptible to early-age cracking due to its low water–cement ratio and dense microstructure. This study experimentally evaluates the restrained drying shrinkage behavior of fiber-reinforced concretes with compressive strengths ranging from 23 to 84 MPa, employing a total of 84 ASTM C1581 ring specimens exposed to three exposure conditions: outdoor climate, indoor laboratory conditions (25 °C, 50% RH), and a controlled chamber (50 °C, 30% RH). Plain concretes exhibited increasing shrinkage with both strength and environmental severity. Under indoor exposure, 90-day shrinkage reached approximately 660 × 10−6 (23 MPa), 291 × 10−6 (40 MPa), 753 × 10−6 (60 MPa), and 338 × 10−6 (84 MPa), with high-strength mixes showing greater cracking susceptibility. Fiber incorporation significantly mitigated both strain and cracking in a dosage-dependent manner. Steel fibers at 1.0–1.5% reduced shrinkage by up to 75% in 40–60 MPa concretes, while polypropylene fibers at 0.25–0.5% achieved reductions up to 66% and eliminated cracking in several cases. Results demonstrate that concrete strength, exposure condition, fiber type, and dosage collectively govern shrinkage and cracking resistance. Full article
Show Figures

Figure 1

2 pages, 143 KB  
Correction
Correction: Steffen et al. Structural Performance of Textile-Reinforced Concrete Sandwich Panels Utilizing GFRP Shear Connectors. Constr. Mater. 2025, 5, 92
by Lukas Steffen, Ismael Viejo, Belén Hernández-Gascón, Mario Stelzmann, Klaus Holschemacher and Robert Böhm
Constr. Mater. 2026, 6(3), 27; https://doi.org/10.3390/constrmater6030027 - 6 May 2026
Viewed by 339
Abstract
There was an error in the original publication [...] Full article
17 pages, 2426 KB  
Article
Effect of X-Cable Bracing on the Optimized Weight of Planar Steel Frames Under Wind Load: A Parametric Study
by Mustafa Al-Bazoon, Saba Jasim Al-Rubaye, Faten I. Mussa, Abdulkhaliq A. Jaafer, Lateef Assi and Mohanad M. Abdulazeez
Constr. Mater. 2026, 6(3), 26; https://doi.org/10.3390/constrmater6030026 - 27 Apr 2026
Viewed by 726
Abstract
In designing tall buildings, the primary concern is ensuring an effective lateral load-resisting system in addition to the gravity load system, since it largely governs the overall design. This study investigates the influence of X-cable bracing on the structural weight of tall steel [...] Read more.
In designing tall buildings, the primary concern is ensuring an effective lateral load-resisting system in addition to the gravity load system, since it largely governs the overall design. This study investigates the influence of X-cable bracing on the structural weight of tall steel frame buildings subjected to service and wind loading. Three numerical case studies, 10-story, 20-story, and 30-story planar steel frames, were modeled and analyzed using SAP2000, then optimized using Differential Evolution (DE) and Enhanced Colliding Bodies Optimization (ECBO) algorithms. These designs were evaluated under both service and wind load conditions, considering strength and drift constraints. The results indicate that the inclusion of wind loads in addition to service loads leads to a higher total structural weight than considering service loads alone, while cable bracing effectively reduces the overall mass by up to 6%, 38%, and 20% for the 10-story, 20-story, and 30-story frames, respectively, compared to unbraced structures, by improving the internal force distribution among structural components. Strength demands, reflected by the interaction ratio, governed all design cases, while lateral displacement was always less than the maximum limit according to AISC and ASCE requirements. Overall, the results highlight the potential of cable bracing systems to deliver efficient tall building designs; however, further studies are needed to generalize these findings to a broader range of building configurations. Full article
Show Figures

Figure 1

15 pages, 1984 KB  
Article
Hydraulic Conductivity of Cracked Concrete Linings
by Jean-Pierre Giroud
Constr. Mater. 2026, 6(3), 25; https://doi.org/10.3390/constrmater6030025 - 23 Apr 2026
Viewed by 518
Abstract
Concrete linings are used for water containment, in particular in reservoirs and canals. When the soil underlying a concrete lining has a high permeability, seepage into the ground of water from concrete-lined reservoirs and canals is essentially governed by leakage of water through [...] Read more.
Concrete linings are used for water containment, in particular in reservoirs and canals. When the soil underlying a concrete lining has a high permeability, seepage into the ground of water from concrete-lined reservoirs and canals is essentially governed by leakage of water through the concrete linings. Therefore, it is essential to properly evaluate the hydraulic conductivity of concrete linings. It is known that cracks generally develop in concrete linings. This article provides material data and a method for the evaluation of the hydraulic conductivity of concrete linings, in particular cracked concrete linings, through two approaches. The first approach consists of a review of selected published values of the measured hydraulic conductivity of intact and cracked concrete. The second approach consists in developing an original analytical method to determine the hydraulic conductivity of cracked concrete using the results of an experimental evaluation of the influence, on water flow, of the tortuosity and rugosity of concrete cracks. The results obtained with the two approaches are compared and numerical examples are presented. Based on these results, practical guidance is provided to design engineers for a safe evaluation of the hydraulic conductivity of concrete linings, cracked or not cracked. Full article
Show Figures

Figure 1

29 pages, 13033 KB  
Article
The Effect of a Polymer–Organic Admixture on the Properties of Recycled Aggregate Concrete with Variable Aggregate Types
by Rauan Lukpanov, Matija Orešković, Artem Chystiakov and Duman Dyussembinov
Constr. Mater. 2026, 6(3), 24; https://doi.org/10.3390/constrmater6030024 - 23 Apr 2026
Viewed by 459
Abstract
In this study, the characteristics of concretes made from mixed recycled aggregate—the cheapest and most common secondary raw material in construction and demolition waste—were determined. For this study, besides experimental concretes using mixed recycled aggregate, reference compositions were developed using river gravel, recycled [...] Read more.
In this study, the characteristics of concretes made from mixed recycled aggregate—the cheapest and most common secondary raw material in construction and demolition waste—were determined. For this study, besides experimental concretes using mixed recycled aggregate, reference compositions were developed using river gravel, recycled concrete aggregate, and recycled masonry aggregate. The workability of concrete mixtures was measured as class S1, which is acceptable for use with slipform concrete pavers, and was achieved by varying the water/cement ratio, considering the different water adsorptions of the concrete fillers. The following mechanical characteristics of the concretes were defined on the 3rd and 28th days: density, compressive strength, flexural strength, water absorption, and frost resistance. The test results showed sufficiently high indicators of strength and durability for the recycled aggregate concretes. Moreover, the strength of the concrete developed from mixed recycled aggregate was comparable with that of the reference concretes. Considering the low strength requirements for the construction of the lower layers of rigid pavements, it was established that such an application of recycled aggregate concrete, including that derived from mixed recycled aggregate, could be permitted. Full article
Show Figures

Figure 1

Previous Issue
Next Issue
Back to TopTop