Next Article in Journal
Design and Simulations of 2D Planar Antenna for Dielectric Characterization of Biological Samples
Previous Article in Journal
A Study of Visible-Blind Properties of a SnO2’s Nanowires Network Photodetector
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Low-Frequency Magnetic Localization of Capsule Endoscopes with an Integrated Coil †

Institute for Electronics Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91058 Erlangen, Germany
*
Author to whom correspondence should be addressed.
Presented at the 8th International Symposium on Sensor Science, 17–28 May 2021; Available online: https://i3s2021dresden.sciforum.net/.
Published: 17 May 2021
(This article belongs to the Proceedings of The 8th International Symposium on Sensor Science)

Abstract

:
Wireless capsule endoscopy is a promising and less invasive alternative to conventional endoscopy. A patient swallows a small capsule with an integrated camera to capture a video of the gastrointestinal tract. For accurate diagnosis and therapy, the capsule position in terms of the travelled distance must be known for each video frame. However, to date, there is no reliable localization method for endoscopy capsules. In this paper, a novel magnetic localization method is proposed. A coil as a magnetic field source is integrated into a capsule and fed with a low-frequency alternating current to prevent static geomagnetic field interference. This alternating magnetic field is measured by twelve magnetic sensors arranged in rings around the abdomen. The coil and the capsule batteries were designed based on the geometry and power supply of a commercially available endoscopy capsule and simulated by COMSOL Multiphysics software. In this way, the coil position and orientation were determined with an accuracy below 1 mm and 1°, respectively. As an analytic model for the magnetic flux density of the coil in that setup, a modified dipole model was derived. It was used to show that the batteries help to increase the amplitude of the magnetic flux density. The model is valid when signals below 100 Hz are applied, and no eddy currents are generated within the batteries. It is concluded that the magnetic flux density generated by the developed coil would be measurable with state-of-the-art magnetic sensors.

Supplementary Materials

The presentation file is available at https://www.mdpi.com/article/10.3390/I3S2021Dresden-10146/s1. Poster presentation: Low-Frequency Magnetic Localization of Capsule Endoscopes with an Integrated Coil.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Zeising, S.; Seidl, R.; Thalmayer, A.; Fischer, G.; Kirchner, J. Low-Frequency Magnetic Localization of Capsule Endoscopes with an Integrated Coil. Eng. Proc. 2021, 6, 38. https://doi.org/10.3390/I3S2021Dresden-10146

AMA Style

Zeising S, Seidl R, Thalmayer A, Fischer G, Kirchner J. Low-Frequency Magnetic Localization of Capsule Endoscopes with an Integrated Coil. Engineering Proceedings. 2021; 6(1):38. https://doi.org/10.3390/I3S2021Dresden-10146

Chicago/Turabian Style

Zeising, Samuel, Rebecca Seidl, Angelika Thalmayer, Georg Fischer, and Jens Kirchner. 2021. "Low-Frequency Magnetic Localization of Capsule Endoscopes with an Integrated Coil" Engineering Proceedings 6, no. 1: 38. https://doi.org/10.3390/I3S2021Dresden-10146

Article Metrics

Back to TopTop