Next Article in Journal
Gut Microbiota’s Effect on Mental Health: The Gut-Brain Axis
Previous Article in Journal
A Case of Shunting Postoperative Patent Foramen Ovale under Mechanical Ventilation Controlled by Different Ventilator Settings
 
 
Clinics and Practice is published by MDPI from Volume 11 Issue 1 (2021). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Brief Report

Reducing Radiation Exposure in an Electrophysiology Lab with Introduction of Newer Fluoroscopic Technology

by
Munish Sharma
1,* and
Koroush Khalighi
2
1
Department of Internal Medicine, Easton Hospital, Easton, PA, USA
2
Department of Cardiology, Easton Hospital, Easton, PA, USA
*
Author to whom correspondence should be addressed.
Clin. Pract. 2017, 7(3), 976; https://doi.org/10.4081/cp.2017.976
Submission received: 30 April 2017 / Revised: 28 June 2017 / Accepted: 28 June 2017 / Published: 11 September 2017

Abstract

The use of fluoroscopic devices exposes patients and operators to harmful effects of ionizing radiation in an electrophysiology (EP) lab. We sought to know if the newer fluoroscopic technology (Allura Clarity) installed in a hybrid EP helps to reduce prescribed radiation dose. We performed radiation dose analysis of 90 patients who underwent various procedures in the EP lab at a community teaching hospital after the introduction of newer fluoroscopic technology in June of 2016.Watchman device insertion, radiofrequency ablation procedures, permanent pacemaker (PPM)/implantable cardioverter defibrillator (ICD) placement and battery changes were included in the study to compare radiation exposure during different procedures performed commonly in an EP lab. In all cases of watchman device placement, radiofrequency ablation procedures, PPM/ICD placement and battery changes, there was a statistically significant difference (<0.05) in radiation dose exposure. Significant reduction in radiation exposure during various procedures performed in an EP lab was achieved with aid of newer fluoroscopic technology and better image detection technology.
Keywords: radiation exposure; electrophysiology lab; newer fluoroscopic system; watchman device; radiofrequency ablation; permanent pacemaker; insertable cardioverter defibrillator radiation exposure; electrophysiology lab; newer fluoroscopic system; watchman device; radiofrequency ablation; permanent pacemaker; insertable cardioverter defibrillator

Share and Cite

MDPI and ACS Style

Sharma, M.; Khalighi, K. Reducing Radiation Exposure in an Electrophysiology Lab with Introduction of Newer Fluoroscopic Technology. Clin. Pract. 2017, 7, 976. https://doi.org/10.4081/cp.2017.976

AMA Style

Sharma M, Khalighi K. Reducing Radiation Exposure in an Electrophysiology Lab with Introduction of Newer Fluoroscopic Technology. Clinics and Practice. 2017; 7(3):976. https://doi.org/10.4081/cp.2017.976

Chicago/Turabian Style

Sharma, Munish, and Koroush Khalighi. 2017. "Reducing Radiation Exposure in an Electrophysiology Lab with Introduction of Newer Fluoroscopic Technology" Clinics and Practice 7, no. 3: 976. https://doi.org/10.4081/cp.2017.976

Article Metrics

Back to TopTop