You are currently on the new version of our website. Access the old version .
EnergiesEnergies
  • This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
  • Article
  • Open Access

25 January 2026

Modeling of Electromagnetic Fields Along the Route of a Gas-Insulated Line Feeding Traction Substations

,
,
,
,
,
,
and
1
Department of Electric Power Engineering of Transport, Irkutsk State Transport University, 664074 Irkutsk, Russia
2
Department of Agriculture Machinery, “Angel Kanchev” University of Ruse, 7017 Ruse, Bulgaria
3
Department of Power Plants, Networks and Systems, Irkutsk National Research Technical University, 664074 Irkutsk, Russia
4
Department of Heat, Hydraulics and Environmental Engineering, “Angel Kanchev” University of Ruse, 7017 Ruse, Bulgaria
Energies2026, 19(3), 624;https://doi.org/10.3390/en19030624 
(registering DOI)

Abstract

Power supply for traction substations (TSs) of AC railways has traditionally been provided by 110–220 kV overhead transmission lines (OHL). These OHLs can be damaged during strong winds and ice formation. Furthermore, these lines generate significant electromagnetic fields (EMFs), which adversely affect maintenance personnel, the public, and the environment. Mitigating the resulting damages requires the establishment of protection zones, necessitating significant land allocation. Enhancing the reliability of power supply to traction substations and reducing EMF levels can be achieved through the use of gas-insulated lines (GIL), whose application in the power industry of many countries is continuously increasing. The aim of the research presented in this article was to develop computer models for determining the EMF of a GIL supplying a group of traction substations, taking into account actual traction loads characterized by non-sinusoidal waveforms and asymmetry. To solve this problem, an approach implemented in the Fazonord AC-DC software package, based on the use of phase coordinates, was applied. This allowed for the correct accounting of the skin effect and proximity effect in the massive current-carrying parts of the GIL, as well as the influence of asymmetry and harmonic distortions. The simulation results showed that the use of GIL brings the voltage unbalance factors at the 110 kV busbars of the traction substations within the permissible range, with the maximum values of these coefficients not exceeding 2%. The results of the harmonic distortion assessment demonstrated a significant reduction in harmonic distortion factors in the 110 kV network for the GIL compared to the OHL. The performed electromagnetic field calculations confirmed that the GIL generates magnetic field strengths one order of magnitude lower than those of the OHL. The obtained results lead to the conclusion that the use of gas-insulated lines for powering traction substations is highly effective, ensuring increased reliability, improved power quality, and a reduced negative impact of EMF on personnel, the public, the environment, and electronic equipment.

Article Metrics

Citations

Article Access Statistics

Article metric data becomes available approximately 24 hours after publication online.