Next Article in Journal
A Simple High-Throughput Method for the Analysis of Vicine and Convicine in Faba Bean
Next Article in Special Issue
Maillard and Hydrolytic Reactions in Subcritical Water Extraction of Bioactive Compounds from Licorice
Previous Article in Journal
Designing a 0D/1D S-Scheme Heterojunction of Cadmium Selenide and Polymeric Carbon Nitride for Photocatalytic Water Splitting and Carbon Dioxide Reduction
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Green Extraction Processes for Complex Samples from Vegetable Matrices Coupled with On-Line Detection System: A Critical Review

by
Francisco W. Maciel-Silva
1,
Daniel Lachos-Perez
2,
Luz Selene Buller
1,
William G. Sganzerla
1,
Montserrat Pérez
3,
Mauricio A. Rostagno
4,* and
Tania Forster-Carneiro
1
1
School of Food Engineering (FEA), University of Campinas (UNICAMP), Campinas 13083-862, SP, Brazil
2
Department of Chemical Engineering, Federal University of Santa Maria, Santa Maria 97105-900, RS, Brazil
3
Department of Environmental Technologies, University of Cadiz, Campus de Puerto Real, S/N, Puerto Real, 11500 Cadiz, Spain
4
School of Applied Sciences (FCA), University of Campinas (UNICAMP), Limeira 13484-350, SP, Brazil
*
Author to whom correspondence should be addressed.
Molecules 2022, 27(19), 6272; https://doi.org/10.3390/molecules27196272
Submission received: 22 August 2022 / Revised: 15 September 2022 / Accepted: 17 September 2022 / Published: 23 September 2022
(This article belongs to the Special Issue Recent Development in Subcritical Water Extraction and Chromatography)

Abstract

:
The detection of analytes in complex organic matrices requires a series of analytical steps to obtain a reliable analysis. Sample preparation can be the most time-consuming, prolonged, and error-prone step, reducing the reliability of the investigation. This review aims to discuss the advantages and limitations of extracting bioactive compounds, sample preparation techniques, automation, and coupling with on-line detection. This review also evaluates all publications on this topic through a longitudinal bibliometric analysis, applying statistical and mathematical methods to analyze the trends, perspectives, and hot topics of this research area. Furthermore, state-of-the-art green extraction techniques for complex samples from vegetable matrices coupled with analysis systems are presented. Among the extraction techniques for liquid samples, solid-phase extraction was the most common for combined systems in the scientific literature. In contrast, for on-line extraction systems applied for solid samples, supercritical fluid extraction, ultrasound-assisted extraction, microwave-assisted extraction, and pressurized liquid extraction were the most frequent green extraction techniques.

Graphical Abstract

1. Introduction

The extraction of bioactive compounds from natural substrates for food, pharmaceutical, and cosmetic applications can be advantageous for producing high value-added products and for nutrients recycling from industrial byproducts and waste [1,2,3], as a circular economy strategy [4,5,6]. Furthermore, the current extraction techniques coupled with on-line detection can be considered more environmentally friendly than conventional techniques [7,8,9].
Currently, most extraction techniques are operated off-line to the analysis system [10,11]. Nevertheless, these processes could be integrated into an on-line system for several cases, where the entire analytical procedure takes place in a closed complex—usually automated. On-line systems could notably provide manifold benefits, including shorter analysis time, better reproducibility, improved detection limits, sensitivity, and results reliability. In addition to avoiding some problems associated with the traditional approach, and its consequent experimental error propagation, on-line sample preparation systems tend to be more productive and less prone to accuracy and precision errors [12].
The sample preparation step aims to isolate the target analytes and to improve the selectivity, precision, and repeatability of the analysis. This step generally includes extraction, concentration, and cleaning procedures for impure and complex samples [13,14]. Meanwhile, these procedures could represent a significant disadvantage, since individual preparation steps substantially increase the risk of sample loss and possible sample contamination, leading to reduced analysis reliability [7,14].
When considering sample preparation and chromatographic analysis, the first is the most time-consuming, tedious, and error-prone step [13], commonly considered by researchers as the bottleneck of the whole analytical procedure [10]. The analysis automation potentially improves the measurement precision, sensitivity, and accuracy, also reducing the consumption of organic solvents [7].
Accordingly, several techniques based on dynamic systems were developed to meet the imminent demand for fastness, sensitivity, repeatability, and reliability [15]. The main available green technologies with coupling capability for on-line detection systems are solid-phase extraction (SPE), supercritical fluid extraction (SFE), liquid-liquid extraction (LLE), microwave-assisted extraction (MAE), ultrasound-assisted extraction (UAE), pressurized liquid extraction (PLE), accelerated solvent extraction (ASE), supercritical water (SCW), and subcritical water (SubCW) [9,10,14,16,17,18,19].
The above-mentioned technologies are more efficient than conventional technologies (maceration, decoction, and Soxhlet extraction) with respect to many aspects, such as lower time demand, higher selectivity, and lower solvents and reagents consumption [12]. These modern technologies are commonly coupled with liquid chromatography (LC), gas chromatography (GC), supercritical fluid chromatography (SFC), and capillary electrophoresis (CE) [11,20]. The SPE and LLE are best suited for liquid samples, as long as the others are usually applied to solid samples [7,15].
Automated flow-based sample treatment systems and separation techniques appear to be a trend in analytical chemistry coupling systems, provided that remarkable assertiveness of analysis results could be achieved [10,11,12]. Moreover, coupled systems are likely to increase the analytical throughputs and efficiency in diversified and easier ways to use on-line systems [21] in a wide range of applications; for instance, for lipophilic samples using SFE with separation based on carbon dioxide (CO2) [9,22], and food drinks with juices, beer, coffee, tea, and water, mainly using the SPE technique [11].
In this context, this article presents a systematic review of extraction systems coupled with on-line analysis systems for solid matrices from vegetable origin. The prevailing publications on extraction processes associated with on-line analysis techniques from 1990 to 2021 were collected and examined. In addition, to evaluate the documents on this topic, statistical and mathematical methods were applied to assess the timeline evolution and future trends of this research field through a longitudinal bibliometric analysis. The results of this review allow the identification of the current state-of-the-art coupling systems for green bioactive compound extraction.
The extraction technologies can be coupled with detection techniques in various ways, depending on the degree of software/hardware automation and human intervention [23]. Accordingly, Figure 1 illustrates the coupling forms, classifying them as off-line, at-line, in-line, and on-line.
The off-line coupling approach includes manual injection of the pre-processed sample into the analysis equipment [24]. This procedure is appropriate for a small number of samples, when conventional methods are expected to be sufficient and there is no need for automated methods [13]. The advantage of carrying out separated processes is a kind of increased flexibility. For LC analysis, it is possible to minimize interferences and undesirable effects related to dirt samples, which may cause bandwidth expansion, overlapping peaks, co-elution with empty volume, and peak asymmetry. Nevertheless, this procedure presents the lowest degree of automation, requiring more time and labor, as well as a risk of sample loss or contamination, which would deliver a lower analysis sensitivity and precision [12].
For at-line coupling, the analyzer is disconnected, yet close to the process [25]. Generally, at-line coupling procedures include a programmable robotic station to link the flow system to the separation or detection instrument. Usually, the pre-treated sample is delivered from the flow system to a vial or to the injector of the analytical instrument [24]. It enables automation and allows for performing a parallel analysis to the flow system with a high precision level, little labor requirement, and low analysis time. Nevertheless, the risk of sample loss or contamination is considered high for this approach [13].
In-line coupling involves complete and close integration of the detection or separation instrument into the flow system [23]. The analyzer is equipped with probes inserted into the process stream, and the analysis is performed in situ [25]. The in-line procedure is entirely automated, promoting more injections while the process is still in progress, which allows a faster response in the feedback cycle. It is possible to implement an automatic periodic cleaning (“self-cleaning”) routine. However, a significant disadvantage is its inability to manipulate samples in parallel because the overall analytical process is restricted to the integrated flow device. Therefore, it does not apply to many methods [12].
The on-line coupling strategy implies direct contact between the flow system and the components of the detection equipment, usually through a flow bypass [11,21]. The analyte from the sample processed in the flow system is transported to an interface and introduced into the pressure-driven separation system in CE [26], mobile phase in LC [14,20] and carrier gas in GC [27]. This configuration enables sequential analysis and high automation capacity, requiring little labor. It is subject to a low possibility of sample loss or contamination, promoting high precision and sensitivity in the analyses. In turn, it requires sophisticated equipment and software, representing high installation costs [12,13]. Similar to in-line methods, a “self-cleaning” routine is possible for on-line methods.
Among other requirements, the robustness of an analysis system under specific process conditions represents an important issue. The demand for in-process analysis equipment is high; the limits of accuracy and detection are often lower than state-of-the-art laboratory equipment. However, the analyses used are typically adapted to the process-specific requirements, leading to highly specialized equipment incorporated into sophisticated control circuits that would allow quality control in real time [23].
Moreover, various technologies are capable of promoting the extraction of bioactive compounds, obtaining a large variety of biochemical products, in addition to platform chemicals. Most of them are viable for foods, pharmaceuticals, and cosmetics [28]. Frequently using these technologies is a relevant strategy for developing a circular economy, since its exceptional advantage in valorizing agro-industrial waste is notable [29]. Furthermore, many current extraction technologies enable on-line or in-line detection system coupling, which is considered more environmentally friendly than conventional technologies [14]. A common trend in extraction technology is to replace the use of toxic reagents with reagents obtained from renewable sources, as well as the integration of analytical processes and operations, saving energy, and reducing the use of reagents [30].

2. Materials and Methods

2.1. Data Collection

The bibliometric analysis retrieved publications from the Web of Science (WoS) core collection, from Clarivate Analytics, using the Science Citation Index Expanded (SCI-Expanded) option. The WoS database presents extensive and multidisciplinary coverage of bibliographic data from leading scientific publications. Consequently, it is a primary information source for academic and bibliometric studies [31,32].
The keywords used to identify the articles in the area of interest were based on a scientific literature search. The terms selected to collect information related to the extraction processes were “solid-phase extraction”, “liquid-liquid extraction”, “supercritical fluid extraction”, “pressurized liquid extraction”, “supercritical water”, “subcritical water”, “accelerated solvent extraction”, “superheated water extraction”, “microwave-assisted extraction” and “ultrasound-assisted extraction”. The terms used for the detection techniques were “chromatography”, “HPLC”, “LC”, “GC”, “UV-detection”, and “supercritical fluid chromatography”. Finally, to assess the integration of processes and detection techniques into an on-line system, the keywords selected were “on-line” and “in-line”.
The bibliometric research was carried out on January 13, 2022, using the TOPIC search field, which combines words in titles, abstracts, author keywords, and keywords defined by the WoS database (keywords plus). The strategy of placing the terms in quotation marks was used to limit the search to publications that contained those terms in that exact word order. The Boolean operators OR (union of terms in groups) and AND (providing an intersection between groups) were used to select the final dataset. A total of 2633 documents published from 1990 to 2021 were found. Furthermore, a refining step was performed to choose only articles and reviews, for which 2353 files were obtained (2146 articles and 207 reviews). The Supplementary Material illustrates the methodology synthesis applied for the data collection and bibliometric analysis.

2.2. Data Processing

The bibliometric analysis was performed using the “Analyzing Results” tool provided by WoS. The number of publications, year of publication, number of citations, types of documents, research areas, and countries were gathered. The graphic illustrations were generated using Origin 8.0 software from OriginLab®. The construction of bibliometric maps based on co-authorship was created using the VOSviewer© 1.6.13 software, providing the graphical representation of bibliometric maps to facilitate data interpretation [33].

3. Results and Discussion

The bibliometric analysis broadly presented all works related to “on-line” and “in-line” coupling systems for: (i) extraction techniques with analysis systems with or without sample purification/cleaning techniques; (ii) extraction techniques with sample purification/cleaning techniques, and (iii) sequential analyses. A detailed bibliometric analysis results description and discussion follows in the next sections.

3.1. Scientific Development of On-Line and In-Line Coupling

The scientific literature data collection regarding on-line and in-line coupling is proven to be relevant worldwide, covering 67 different countries in the total publication period assessed. Figure 2 shows the evolution of the number of publications and highlights the main research areas.
Figure 2A emphasizes the advancements in annual publications, while Figure 2B focuses on the total breakthrough of the works performed. The publishing started in 1990 with only one document, and rapid growth in the following years is observed. The publishing peak occurred in 2007, with 123 studies. Since 1995, studies in this area reached the mark of more than 60 annual publications, exposing the broad scope and the particular importance of this area for the international scientific community. From 2005, more than 80 yearly publications were identified, except for the years 2020 and 2021, in which only 69 and 48 papers were found, respectively (a decrease may be associated with the COVID-19 pandemic).
In the 32 years of publications in this field, a total of 2353 papers were produced, arranged in six main research areas according to the Web of Science categories: “Chemistry Analytical”, “Biochemical Research Methods”, “Food Science Technology”, “Spectroscopy”, “Environmental Sciences”, and “Pharmacology Pharmacy”. These categories played an essential role in the development of this subject. Since the beginning of publications, the Chemistry Analytical area led the ranking, followed by Biochemical Research Methods. The other areas of the top six have a similar number of papers, and they change positions in the ranking over the years. The Food Science Technology area currently occupies the third position, with 158 articles. Fourth, it is the Spectroscopy area with 146. Environmental Sciences is in fifth with 145, and in sixth is Pharmacology Pharmacy with 143. The Environmental Sciences area is currently in evidence due to increased environmental concerns.

3.2. International Collaboration

Research partnerships between the leading countries in the on-line and in-line coupling areas were evaluated. The evaluation of international collaboration was carried out through the bibliometric analysis applied to co-authorship and the number of cumulative publications with chosen thresholds to understand how the connections were established. Figure 3 shows a bibliometric network in which the size of the marker is proportional to the number of accumulated publications, as well as the thickness of the lines that make the connections between the stamps, and the colors indicate to which cluster the item belongs. Furthermore, it is noteworthy that the number of subjects was limited to display only the top 30 countries.
The bibliometric map presented in Figure 3 shows six clusters among the thirty most productive countries. The red-colored cluster has the largest number of countries (corresponding to 10 items). The clusters with the least number of items are the orange and purple ones, both with only two countries. The group responsible for the smallest number of publications is purple, accounting for 72 articles. The cluster with the most considerable incidence (red) accounts for 970 articles, and the second-largest, the yellow one, presents 560 reports. Although there are two clusters with six countries and the yellow one contains only four, the last is placed in the second position in the number of publications containing Spain, which is the most productive country.
Spain, China, and the USA significantly contributed to this research field, with 19.29%, 17.30%, and 11.81% of the scientific recordings, respectively. These countries published a considerable number of scientific articles collaboratively with other countries. However, when analyzing the number of international collaborations, the rank varied as follows: the USA started as the leader, having published in partnership with 32 countries, followed by Spain, with 31 countries; the third country is Germany, which collaborated with 24 countries. Finally, China dropped to the fourth position, with 23 international collaborations.

3.3. Journals with More Publications and Most Cited Articles

All of the articles found in the research area of extraction with on-line detection systems were published in 282 different journals, which illustrates the diversity of publications and broad interest in this research field from multiple perspectives. Notwithstanding, most journals (approximately 91%) published fewer than 20 articles, accounting for only 25 journals publishing 20 or more reports. Otherwise, this set is responsible for approximately 71% of the publications. Consequently, it can be inferred that those 25 journals are the most chosen for this research area. According to Bradford’s law, this distorted distribution is expected in the bibliometric analysis, since journals are dedicated to specific topics [34] and about 500 to 1000 journals are needed to cover 95% of the “significant” literature published in a given field [35]. Accordingly, Table 1 presents the ten most active journals responsible for 53% of the publications.
From Table 1, it can be observed that the Journal of Chromatography A leads the ranking with approximately 16% of the total publications, more than double the publications in Talanta, the second journal in the ranking. Both journals belong to the company Elsevier, which also corresponds to the third, fourth, and eighth journals in the ranking. This publisher is responsible for the four journals with the most significant number of publications and accounted for five journals in the top ten. Among the top ten journals, the other publishing company is ACS Publications, responsible for the fifth ranking position, with the most significant impact factor (6.986). Springer, responsible for two journals, tied for the sixth position in the ranking. Finally, the Wiley Online Library is responsible for the ninth and tenth positions.
The analysis of the ten most cited articles until 2021 (Table 2) revealed no direct relationship between citations in a specific publication and the most active journals in the area. The most cited article was published by Chemosphere, which is not among the top ten journals, occupying the 23rd position in the ranking and accounting for 18 publications. On the other hand, the Journal of Chromatography A, the journal’s ranking leader (Table 1), was the only journal with more than one publication among the top ten most cited articles.
The work presenting the highest number of citations is a critical review focused on phosphorus flame retardants [37], which dealt with properties, production, environmental occurrence, toxicity, and analysis issues. This large variety of issues may explain why different researchers from different areas cited it.
Finally, five of the most cited articles [37,39,40,44] do not belong to the top ten journals in terms of publications. In addition to the first in the ranking and the third most cited article [39], which was published by Trends in Analytical Chemistry, the journal presents 34 publications in the on-line coupling field and ranks thirteenth. The other articles are the fourth [40] and the eighth [44] on the list, belonging to the Accounts of Chemical Research and Glycoconjugate Journal, respectively. Both journals have only one article in this field of study. Finally, the 10th position [46] belongs to Environmental Science & Technology. This journal presents 20 articles in the field and occupies the 25th position in the ranking of the top journals.
Beyond the fifth, sixth, and seventh, the first three most cited articles belong to Elsevier journals, totalizing six reports from the list. The fourth, ninth, and tenth articles belong to ACS Publications, and the eighth article is from Springer. The top five publishers in numbers of published articles are Elsevier, Wiley, Springer, ACS Publications, and the Royal Society of Chemistry, with 1204, 290, 183, 141, and 102 articles, respectively. Another critical detail in Table 2 is that most of the included works are reviews, and only three documents refer to research articles (eighth, ninth, and tenth).

3.4. Keyword Analysis

The keywords are essential sources of information because they provide evidence for the issues and central themes in a publication [47]. The terms used as keywords can be used to investigate the research trajectory, to analyze trends in a research area, and to investigate the existing knowledge gaps in a certain scientific field [31]. Therefore, the 30 main authors’ keywords and keywords plus (provided by WoS, based on a unique special algorithm to increase the power of cited reference search) of the research field analyzed in this review are highlighted in Table 3.
The examination of the keywords in the 32 years of publication revealed that 8626 terms were already used to characterize searches about on-line and in-line coupling (with 4679 author keywords and 4927 keywords plus), suggesting the existence of a great diversity of research themes. Another argument reinforces this hypothesis: the VOSviewer software frequency analysis revealed that 6042 keywords were used only once. According to Chuang, Huang, and Ho [48], many unique keywords probably indicate a lack of continuity and a significant disparity in the research focus.
Table 3 shows that the term most used was “Solid-phase extraction”, either when chosen by the authors or the WoS. In addition to this term, the two columns present eighteen (18) repeated keywords. It is also possible to observe that the keywords plus have more occurrences than the authors’ keywords. Furthermore, 77.4% of the terms in the authors’ keywords appeared in only one article, and that number was 64.3% for keywords plus.
It is possible to consider three main groups of keywords in the study area: samples, process techniques, and analysis techniques.
The main terms related to the sample group are “Urine”, “Plasma”, “Human plasma”, “Pesticides”, “drugs”, “residues”, “Waste-water”, “Water”, and “Water samples”, suggesting that automation using on-line and in-line coupling is more advanced in the area of health, water treatment, and food products.
For process techniques, there are general terms, such as “Sample preparation”, “Preconcentration”, “On-line pre-concentration”, “Extraction”, “On-line extraction”, “Separation”, and “Microextraction”. In addition, specific terms, such as “Solid-phase extraction”, “On-line solid-phase extraction”, “On-line SPE”, and “Supercritical fluid extraction” are present. Currently, SPE is one of the most used techniques for the extraction and/or concentration of complex samples, allowing analytes in deficient concentrations to be detected by methods such as high-performance LC, GC, and CE [11,20].
In general, the use of the word “on-line” is more performed by the authors. Moreover, for the keywords plus, the term appeared disassociated with the process technique. For plus keywords, the analysis of the association between them, using VOSviewer software, showed that the term “Solid-phase extraction” appeared highly associated with “High-performance liquid chromatography”. For the author keywords, the term “Solid-phase extraction” appeared more associated with “Capillary electrophoresis”.
The main terms of the analysis techniques group are “Mass spectrometry”, “Capillary electrophoresis”, “Liquid chromatography”, “Tandem mass spectrometry”, “Chromatography”, “Identification”, and “Quantification”. It was found that among the keywords of this group, there is an extensive use of synonyms, such as “Liquid chromatography”, “High-performance liquid chromatography”, “Column liquid chromatography”, “HPLC”, “LC-MS”, and “LC-MS/MS”. The two last terms mean LC coupled to mass spectrometry, with one or two detectors, also known as tandem mass spectrometry.

4. Innovative Extraction Techniques Suitable for On-Line Coupling

From the bibliometric analysis results, it was possible to collect, to review, and to assess state-of-the-art on-line coupling systems. The main findings are further scrutinized and critically analyzed.
Several extraction systems can be coupled on-line with analysis systems using liquid and solid samples. Liquid samples are more straightforward to operate than solid samples, considering that on-line sample preparation techniques are broadly based on continuous flow approaches (which are especially suitable for liquids).
Among the extraction techniques for liquid samples, SPE is the most common in combined systems [7,13]. In SPE, the compounds dissolved or suspended in a liquid mixture are extracted using an interface coupled or not with solid extraction techniques and chromatography [49]. Otherwise, the solid matrix analytes are first extracted through polar or nonpolar solvents before the analysis. The most common on-line extraction systems for solid samples are SFE, UAE, MAE, and PLE. The coupling is usually performed with the aid of multiport valves. In cases where the extracts have a high content of soluble solids or a high concentration of impurities, SPE is used for in-line purification [50]. Figure 4 shows a simplified diagram of the primary extraction and analysis techniques for on-line coupling.
On-line extraction systems can be carried out in either static or dynamic mode. In the context of transferring the extract to the analytical system, the dynamic mode is the most common, and the analytes are removed continuously from the sample to the fluid (solvent). Furthermore, as the sample is continually exposed to the solvent, the transfer of analytes from the sample matrix to the solvent is enhanced [13]. Therefore, for solid samples, low flow rates and extract volumes of less than 1–2 mL must be kept. Otherwise, the extract must be concentrated before transferring it to the analytical system.
Another option is in-line SPE coupling. Several works in the literature demonstrated that SPE considerably improves concentration and sensitivity when diluted samples are analyzed and makes it possible to analyze complex matrices by extracting solids, enabling simple coupling [51]. The solvent (or fluid) is continuously washed through the SPE extractor at a constant flow rate for a specified period.
Furthermore, the solvent (or fluid) must be compatible if the analytical system is chromatographic (mobile phase for LC and carrier gas for GC). It is essential to highlight that the solvent (or fluid) must be sufficiently volatile and preferably nonpolar when coupled with the GC. On the other hand, the extracts should preferably be a weak strength eluent for coupling with the LC system [7,13]. The following sections will delve into extraction systems coupled on-line with analytical techniques for vegetable origin solid matrices.

4.1. Supercritical Fluid Extraction

SFE is an attractive, green, novel technique that uses supercritical fluids (typically carbon dioxide). Due to its selectivity in adjusting the temperature or pressure, it is possible to obtain extracts with a low concentration of undesired compounds. Moreover, with the addition of a modifier to CO2, termed cosolvent, the efficiency of the extraction of more polar analytes is possible and a wide variety of compounds of different polarity can be recovered. In this regard, it is essential to highlight that SFE is hardly matrix-dependent, and therefore, the chosen chromatographic technique will depend on the sample and analytes chemical composition [52,53].
SFE is well-suited for on-line coupling systems (LC, GC, and SFC), considering that CO2 becomes gaseous upon depressurization and it is easily removed from a flow system. Additionally, SFE produces clean extracts with minimal residual organic solvents and usually does not require additional analytes pre-concentration before the chromatographic analysis [7,52]. In general, on-line coupling systems employ intermediate trapping, multiport valves, and one or more pumps for the dynamic extraction or for transferring the extract to the chromatographic system. As mentioned above, on-line coupling systems can be carried out in either static, dynamic, or as a combination of both modes. Table 4 presents the different SFE on-line coupling systems, conditions (feed, pressure, and temperature), static and dynamic modes of different samples, and detectors.
On-line SFE coupled to LC is technically a challenge due to the incompatibility of the technique that produces a large volume of gas (normally CO2) while using liquid as a mobile phase. Therefore, a crucial requirement is to keep a gas-free mobile phase to avoid bubbles that promote an unstable pump performance and detector sensitivity loss [57,61,62,63]. Hamada et al. [55], studied the coupling system SFE-SPE-LC-MS for on-line extraction and trap columns in green, yellow, and red peppers, presenting excellent results with the concentration column with a six-port valve. The interfaces based on a split/splitless injector, an on-column injector, or a programmable temperature vaporizer were less common in on-line SFE coupled to LC than in SFE coupled to SFC [27,64,65,66,67].
Zhang et al. [16] presented a coupling system SFE-SFC with a photodiode array detector (PDA) for the rapid determination of oleanolic acid and ursolic acid in Chaenomelis Fructus within 40 min (10.79 mg/g dry plant, Rs = 2.36). Additionally, coupling the SFE-SFC system with the PDA detector, compared with other off-line methods obtained, higher extraction yields for all four aromatic constituents of vanilla beans. The direct on-line extraction and determination by SFE with chromatography and mass spectrometry were studied for apocarotenoids and carotenoids compound extraction. The results show a very fast extraction yield at 80 °C, in less than 17 min for monoesters and diesters carotenoids [59]; and apocarotenoids and apocarotenoids fatty acid esters were detected in yellow tamarillo through conventional and sub-2-micron particle C30 columns [56].
Although the on-line SFE-GC system might seem simple, the flow rate of the CO2 increases after depressurization, and the volume of the gas is significant, the only coupling is found at the output of the system, not through an interface valve. Handling such a high flow rate and a large gas volume requires careful selection of the interfacing technique, if pressurized. Finally, SFC is an analytical technique that uses supercritical fluid as a mobile phase. Although SFC has some advantages, such as high resolution and high throughput, its development and application are not widely used as GC and LC, due to some aspects related to instrumental particularities and a complex handling of diverse operational variables, which can lead to a complicated optimization process [58,68,69,70,71].

4.2. Ultrasound-Assisted Extraction

Ultrasound is an intensification extraction technique widely used to improve the removal of analytes from a solid sample matrix. UAE is widely applied due to faster extractions, high reproducibility, simplification of manipulation and processing, and higher purity of the final product, allowing lower consumption of solvents and energy compared to conventional extraction techniques. Only five works approaching UAE systems coupled on-line with GC were identified [72,73,74,75,76]. Table 5 presents UAE coupled systems’ operational conditions (retention time, pressure, and temperature) for different samples.
Zhang et al. [77] studied a novel UAE with an on-line solvent concentration system highly automated. The results show the extraction of several chemicals by coupling parallel counter-current chromatography. This UAE system has unique advantages, where extraction of materials and purification of the extract can be simultaneously achieved, thereby reducing the “liquid-liquid” purification steps. The process also enables continuous feeding, slag discharge, and liquid discharge, which improves the extraction [81]. Falkova et al. [78] studied an automated flow batch-based determination of anthraquinones with on-line ultrasound-assisted surfactant-mediated extraction by one sequential injection and another stepwise injection. The results show sampling frequencies of 12 h−1 for SIA and 6 h−1 for stepwise injection, respectively. Similar studies with continuous UAE incorporated into an on-line flow injection manifold were used for the determination of zinc in meat samples by flame atomic absorption spectrometry, and the flow injection methodology allowed a sampling frequency of 80 samples per hour [82].
The cited works presented on-line combinations in dynamic mode: (i) a predetermined volume of solvent flows through the solid matrix that is static and fixed in the extractor, termed a semi-continuous process, and (ii) solvent and the solid matrix continuously flow through an ultrasonic bath, termed a continuous process.
Dynamic extraction (semi-continuous or continuous) is favorable in many aspects: the analytes are removed as soon as they are transferred from the solid matrix to the solvent, and the continuous exposure to fresh solvent enhances the transfer of analytes from the sample matrix to the solvent.

4.3. Microwave-Assisted Extraction

MAE is a well-established green extraction technique widely acknowledged as rapid, easy to operate, and efficient for solid and complex matrices [83,84]. The microwave energy heats the solvent in contact with the matrix, solubilizing the analytes. The solvent or even the sample must be dielectric. Therefore, the dielectric constant is one of the critical parameters associated with MAE. Due to this fact, it is crucial to select solvent mixtures to alter the dielectric constant until suitable characteristics are achieved for the extracted sample. Good extraction efficiencies are observed in the scientific literature. Several of them are similar to or higher than classical techniques, such as Soxhlet, SFE, or PLE [83]. Moreover, MAE solvent consumption and extraction time are lower than classical techniques, facilitating on-line analysis [84]. Table 6 presents MAE coupled techniques, operational conditions, methods (static mode and dynamic mode) for different samples, and composts of interest.
Gao et al. [85], studied on-line ionic liquid-based dynamic microwave-assisted extraction with high-performance liquid chromatography (DMAE-HPLC) to determine lipophilic constituents in an herbaceous substrate; the proposed method showed a homogeneous and stable analytes suspension when compared with the off-line ionic liquid-based DMAE and other methods. Additionally, another DMAE-HPLC coupling system showed optimal conditions for extracting Andrographis and Andrographolide for a flow of 1.0 mL/min, microwave power of 80 W, and extraction time of 6 min in 60% of aqueous methanol [87]. Wang et al. [86], studied DMAE coupled on-line with a cleaning up process (silica gel column) to remove chlorophyll from tea; the proposed method presented higher selectivity and sensitivity than conventional extraction methods, such as Soxhlet and LLE. In other studies, the analytes were automatically transferred from the SPE column to the analytical column, with a UV detector at 238 nm [51,87], a PAD detector [49] and a UV detector monitoring at 270 nm [86].
MAE may be a promising on-line coupling technique. Nevertheless, only limited research on food substrates were published [85,89].

4.4. Pressurized Liquid and Subcritical Water Extraction

PLE, also known as accelerated solvent extraction (ASE) or pressurized solvent extraction (PSE), extracts a sample using conventional solvents under high temperature and pressure. When the PLE technique operates with solvent water (or fluid) at different pressures, different terms can be used to define this technique: hot water extraction (HWE), subcritical water extraction (SubCWE), and pressurized hot water extraction (PHWE). PLE technique employs high temperatures and pressures that can increase the solvating power, decrease the viscosity, and increase the diffusion rate [2,90].
Therefore, PLE is a promising, environmentally friendly, and faster extraction technique than conventional solid–liquid extraction techniques, such as Soxhlet extraction. The temperature and pressure parameters improve the solubility, mass transfer, and increase the disruption of the surface equilibrium [2,91]. Table 7 presents the different PLE studies on vegetal origin solid samples with coupled on-line detection systems, detailing the sample used, analyte, PLE and LC conditions, and type of detection.
Some publications approaching SubCWE on-line with either LC or GC in a dynamic mode were reported, and the samples analyzed were soils, sediments, and wastewater [97,98,99,100,101]. The growing interest in the SubCWE might be associated with the fact that water is environmentally friendly and intimately related to LC. SubCWE systems coupled on-line with LC are frequently applied because the solubility of the analytes extracted in water decreases dramatically when subcritical water is cooled down; trapping analytes before LC analysis is therefore relatively accessible. The analytes are collected either to a solid-phase trap (SP-trap) for LC or GC, or even in a membrane extraction unit for GC. SubCWE-LC coupling with an SP-trap is simpler than SubCWE-GC coupling, since the extract from the SP-trap can be directly eluted to the LC column by an appropriate eluent [100,101]. Therefore, SubCWE successfully shows the potential of this integrated approach. SubCWE is inherently limited to using water, and its properties change in a subcritical state, where water above 300 °C behaves similarly to organic solvents [28].
The choice of analytical system type is primarily determined by the specific requirements of the sample, i.e., sample composition and complexity, and amount/concentration of analytes. For these reasons, the works with PLE presented on-line coupling only with LC, unlike SubCWE, which had studies using coupling with GC systems. This aspect is probably associated with the high eluent strength of the organic solvents usually applied for PLE. Then, the volumes used are usually significant to efficiently trap the analytes into the SP-trap sorbent [13,93]. Therefore, methods that can effectively couple PLE to chromatography via on-line solid-phase trapping/pre-concentration would be beneficial to explore. Some works were reported using on-line coupling PLE-LC systems [102,103], and those that used solid samples of plant origin are detailed in Table 7.

5. Future Directions

From this systematic review, it is clear that there is a need to continue the development of green extraction systems coupled with on-line analysis systems for solid matrices of vegetable origin. Through the coupling of more advanced techniques, it is possible to obtain several benefits, including shorter operating time, ease of operation, better reproducibility, improved detection limits, greater sensitivity, and reliability of the results.
A common trend in current extraction and analysis technologies is the search for replacing the use of toxic reagents with green reagents obtained from renewable sources and the integration of extraction processes and analytical operations, saving energy and reducing the use of reagents. For chromatography, the main analysis technique that provides a lot of detailed information, alternative reusable solvents, such as eutectic solvents and ionic liquids, are sought for use as a mobile phase. The development of chromatography can reduce analysis time, improve separations, and obtain more accurate information. This evolution is carried out through the elaboration of more efficient columns, with smaller lengths and smaller filling particles. Additionally, the use of SFC to replace the LC mainly in normal phase and the enhancement of detectors are key points for on-line detection.
On-line detection can be used not only to monitor the process, but also to characterize samples and extracts in real time, providing greater quality and speed in obtaining information. Through the advancement of bioinformatics and artificial intelligence, a greater automation of processes will be possible, making it easier to calibrate equipment to identify certain failures, and allowing for the ability to interrupt or make adjustments to the process that is currently taking place.
In addition, the use of the coupling of these technologies can be a relevant strategy for the development of a circular economy. The benefits of the revalorization of agro-industrial waste are remarkable, and the establishment of biorefineries producing high value-added ingredients makes it possible to take full advantage of vegetable matrices.

6. Conclusions

Research on the automation and coupling of extraction processes with on-line detection started in 1990. The total number of publications reached the mark of 2353 articles, and since 1995, more than 60 publications are made annually, except in the last year of 2020. Spain published most of these studies, while the USA had the largest network of international partnerships. The most cited articles are primarily reviews, and their volume of information (among other aspects) is one of the reasons for the high number of citations. Advanced extraction techniques for solid matrices on-line systems coupled to chromatography (LC, GC, and SFC) are usually performed in dynamic mode with innovative techniques, such as SFE, UAE, MAE, PLE, and SubCWE. On-line coupling systems employ intermediate trapping, multiport valves, and one or more pumps for the dynamic extraction or transfer of the extract to the chromatographic system. The on-line coupling of an extraction to a chromatographic technique allows the entire analysis to be performed in a closed system. The main advantages are improved sensitivity, minimal sample contamination, and the possibility of a fully automated analytical system. For solid samples, more complex solutions are required for on-line analysis than for liquid samples. It usually requires some adaptation and optimization, as well as special knowledge of the underlying principles. However, the time invested in optimizing conditions is quickly paid back in terms of more efficient sample throughput, better reproducibility, and improved sensitivity.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/molecules27196272/s1, Figure S1: Methodological synthesis applied to the bibliometric analysis.

Author Contributions

Conceptualization, T.F.-C., M.A.R. and M.P.; investigation, F.W.M.-S., D.L.-P., L.S.B. and W.G.S.; writing—original draft preparation, F.W.M.-S., D.L.-P., L.S.B. and W.G.S.; writing—review and editing, F.W.M.-S., D.L.-P., L.S.B., W.G.S., T.F.-C., M.A.R. and M.P.; supervision, T.F.-C., M.A.R. and M.P. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Higher-Level Personnel Improvement Coordination (CAPES), grant number 001; São Paulo Research Foundation (FAPESP), grant number 2016/50612-8; 2018/05999-0; 2018/14938-4; 2018/14582-5; 2019/08542-3; 2020/10323-5.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Acknowledgments

Forster-Carneiro T. and Rostagno M.A. thank the Brazilian Science and Research Foundation (CNPq) for the productivity grants 302473/2019-0 and 302451/2021-8.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Mayanga-Torres, P.C.; Lachos-Perez, D.; Rezende, C.A.; Prado, J.M.; Ma, Z.; Tompsett, G.T.; Timko, M.T.; Forster-Carneiro, T. Valorization of Coffee Industry Residues by Subcritical Water Hydrolysis: Recovery of Sugars and Phenolic Compounds. J. Supercrit. Fluids 2017, 120, 75–85. [Google Scholar] [CrossRef]
  2. Lachos-Perez, D.; Baseggio, A.M.; Mayanga-Torres, P.C.; Maróstica, M.R.; Rostagno, M.A.; Martínez, J.; Forster-Carneiro, T. Subcritical Water Extraction of Flavanones from Defatted Orange Peel. J. Supercrit. Fluids 2018, 138, 7–16. [Google Scholar] [CrossRef]
  3. Lachos-Perez, D.; Tompsett, G.A.; Guerra, P.; Timko, M.T.; Rostagno, M.A.; Martínez, J.; Forster-Carneiro, T. Sugars and Char Formation on Subcritical Water Hydrolysis of Sugarcane Straw. Bioresour. Technol. 2017, 243, 1069–1077. [Google Scholar] [CrossRef] [PubMed]
  4. Keijer, T.; Bakker, V.; Slootweg, J.C. Circular Chemistry to Enable a Circular Economy. Nat. Chem. 2019, 11, 190–195. [Google Scholar] [CrossRef]
  5. Raud, M.; Kikas, T.; Sippula, O.; Shurpali, N.J. Potentials and Challenges in Lignocellulosic Biofuel Production Technology. Renew. Sustain. Energy Rev. 2019, 111, 44–56. [Google Scholar] [CrossRef]
  6. Kumar, N.; Pruthi, V. Potential Applications of Ferulic Acid from Natural Sources. Biotechnol. Rep. 2014, 4, 86–93. [Google Scholar] [CrossRef]
  7. Pan, J.; Zhang, C.; Zhang, Z.; Li, G. Review of Online Coupling of Sample Preparation Techniques with Liquid Chromatography. Anal. Chim. Acta 2014, 815, 1–15. [Google Scholar] [CrossRef] [PubMed]
  8. Mandal, V.; Tandey, R. A Critical Analysis of Publication Trends from 2005–2015 in Microwave Assisted Extraction of Botanicals: How Far We Have Come and the Road Ahead. TrAC Trends Anal. Chem. 2016, 82, 100–108. [Google Scholar] [CrossRef]
  9. Zoccali, M.; Donato, P.; Mondello, L. Recent Advances in the Coupling of Carbon Dioxide-Based Extraction and Separation Techniques. TrAC Trends Anal. Chem. 2019, 116, 158–165. [Google Scholar] [CrossRef]
  10. Frenzel, W.; Markeviciute, I. Membrane-Based Sample Preparation for Ion Chromatography—Techniques, Instrumental Configurations and Applications. J. Chromatogr. A 2017, 1479, 1–19. [Google Scholar] [CrossRef]
  11. Mejía-Carmona, K.; Jordan-Sinisterra, M.; Lanças, F.M. Current Trends in Fully Automated On-Line Analytical Techniques for Beverage Analysis. Beverages 2019, 5, 13. [Google Scholar] [CrossRef]
  12. Clavijo, S.; Avivar, J.; Suárez, R.; Cerdà, V. Analytical Strategies for Coupling Separation and Flow-Injection Techniques. TrAC Trends Anal. Chem. 2015, 67, 26–33. [Google Scholar] [CrossRef]
  13. Hyötyläinen, T.; Riekkola, M.-L. Approaches for On-Line Coupling of Extraction and Chromatography. Anal. Bioanal. Chem. 2004, 378, 1962–1981. [Google Scholar] [CrossRef] [PubMed]
  14. Borisova, D.R.; Statkus, M.A.; Tsysin, G.I.; Zolotov, Y.A. On-Line Coupling of Solid-Phase Extraction of Phenols on Porous Graphitic Carbon and LC Separation on C18 Silica Gel Column via Subcritical Water Desorption. Sep. Sci. Technol. 2016, 51, 1979–1985. [Google Scholar] [CrossRef]
  15. Rutkowska, M.; Płotka-Wasylka, J.; Sajid, M.; Andruch, V. Liquid–Phase Microextraction: A Review of Reviews. Microchem. J. 2019, 149, 103989. [Google Scholar] [CrossRef]
  16. Zhang, X.; Ji, F.; Li, Y.; He, T.; Han, Y.; Wang, D.; Lin, Z.; Chen, S. Rapid Determination of Two Triterpenoid Acids in Chaenomelis Fructus Using Supercritical Fluid Extraction On-Line Coupled with Supercritical Fluid Chromatography. Anal. Sci. 2018, 34, 407–413. [Google Scholar] [CrossRef] [PubMed]
  17. Aly, A.A.; Górecki, T. Green Approaches to Sample Preparation Based on Extraction Techniques. Molecules 2020, 25, 1719. [Google Scholar] [CrossRef]
  18. Carreira-Casais, A.; Lourenço-Lopes, C.; Otero, P.; Rodriguez, M.C.; Pereira, A.G.; Echave, J.; Soria-Lopez, A.; Chamorro, F.; Prieto, M.A.; Simal-Gandara, J. Application of Green Extraction Techniques for Natural Additives Production. In Natural Food Additives; Lourenço-Lopes, C., Ed.; IntechOpen: Rijeka, Croatia, 2021; Chapter 5; ISBN 978-1-83968-960-4. [Google Scholar]
  19. Armenta, S.; Garrigues, S.; Esteve-Turrillas, F.A.; de la Guardia, M. Green Extraction Techniques in Green Analytical Chemistry. TrAC Trends Anal. Chem. 2019, 116, 248–253. [Google Scholar] [CrossRef]
  20. Sammani, M.S.; Clavijo, S.; González, A.; Cerdà, V. Development of an On-Line Lab-on-Valve Micro-Solid Phase Extraction System Coupled to Liquid Chromatography for the Determination of Flavonoids in Citrus Juices. Anal. Chim. Acta 2019, 1082, 56–65. [Google Scholar] [CrossRef]
  21. Liang, Y.; Zhou, T. Recent Advances of Online Coupling of Sample Preparation Techniques with Ultra High Performance Liquid Chromatography and Supercritical Fluid Chromatography. J. Sep. Sci. 2019, 42, 226–242. [Google Scholar] [CrossRef] [PubMed]
  22. Sánchez-Camargo, A.d.P.; Parada-Alonso, F.; Ibáñez, E.; Cifuentes, A. Recent Applications of On-Line Supercritical Fluid Extraction Coupled to Advanced Analytical Techniques for Compounds Extraction and Identification. J. Sep. Sci 2019, 42, 243–257. [Google Scholar] [CrossRef] [PubMed]
  23. Kandelbauer, A.; Rahe, M.; Kessler, R.W. Process Control and Quality Assurance-Industrial Perspectives. In Handbook of Biophotonics, Photonics in Pharmaceutics, Bioanalysis and Environmental Research; Popp, J., Tuchin, V., Chiou, A., Heinemann, S., Eds.; Wiley-VCH: Weinheim, Germany, 2012; Volume 3, p. 320. ISBN 978-3-527-41049-1. [Google Scholar]
  24. Trojanowicz, M. Advances in Flow Analysis. John Wiley & Sons: Hoboken, NJ, USA, 2008; ISBN 3527318305. [Google Scholar]
  25. Minnich, C.; Hardy, S.; Krämer, S. Stopping the Babylonian Confusion: An Updated Nomenclature for Process Analyzers in PAT Applications. Chem. Ing. Tech. 2016, 88, 694–697. [Google Scholar] [CrossRef]
  26. Cindric, M.; Matysik, F.-M. Coupling Electrochemistry to Capillary Electrophoresis-Mass Spectrometry. TrAC Trends Anal. Chem. 2015, 70, 122–127. [Google Scholar] [CrossRef]
  27. Hyötyläinen, T. On-Line Coupling of Extraction with Gas Chromatography. J. Chromatogr. A 2008, 1186, 39–50. [Google Scholar] [CrossRef] [PubMed]
  28. Prado, J.M.; Lachos-Perez, D.; Forster-Carneiro, T.; Rostagno, M.A. Sub- And Supercritical Water Hydrolysis of Agricultural and Food Industry Residues for the Production of Fermentable Sugars: A Review. Food Bioprod. Process. 2016, 98, 95–123. [Google Scholar] [CrossRef]
  29. Seroka-Stolka, O.; Ociepa-Kubicka, A. Green Logistics and Circular Economy. Transp. Res. Procedia 2019, 39, 471–479. [Google Scholar] [CrossRef]
  30. Gałuszka, A.; Migaszewski, Z.; Namieśnik, J. The 12 Principles of Green Analytical Chemistry and the SIGNIFICANCE Mnemonic of Green Analytical Practices. TrAC Trends Anal. Chem. 2013, 50, 78–84. [Google Scholar] [CrossRef]
  31. Romanelli, J.P.; Fujimoto, J.T.; Ferreira, M.D.; Milanez, D.H. Assessing Ecological Restoration as a Research Topic Using Bibliometric Indicators. Ecol. Eng. 2018, 120, 311–320. [Google Scholar] [CrossRef]
  32. Gonçalves, M.C.P.; Kieckbusch, T.G.; Perna, R.F.; Fujimoto, J.T.; Morales, S.A.V.; Romanelli, J.P. Trends on Enzyme Immobilization Researches Based on Bibliometric Analysis. Process Biochem. 2019, 76, 95–110. [Google Scholar] [CrossRef]
  33. van Eck, N.J.; Waltman, L. Software Survey: VOSviewer, a Computer Program for Bibliometric Mapping. Scientometrics 2010, 84, 523–538. [Google Scholar] [CrossRef] [Green Version]
  34. Ram, S.; Paliwal, N. Assessment of Bradford Law of Scattering to Psoriasis Literature through Bibliometric Snapshot. DESIDOC J. Libr. Inf. Technol. 2014, 34, 46–56. [Google Scholar] [CrossRef]
  35. Okubo, Y. Bibliometric Indicators and Analysis of Research Systems; Methods and Examples: Paris, France, 1997. [Google Scholar]
  36. JCR Journal Citation Reports. Available online: https://jcr.clarivate.com/JCRLandingPageAction.action (accessed on 12 January 2022).
  37. van der Veen, I.; de Boer, J. Phosphorus Flame Retardants: Properties, Production, Environmental Occurrence, Toxicity and Analysis. Chemosphere 2012, 88, 1119–1153. [Google Scholar] [CrossRef] [PubMed]
  38. Hennion, M.-C. Solid-Phase Extraction: Method Development, Sorbents, and Coupling with Liquid Chromatography. J. Chromatogr. A 1999, 856, 3–54. [Google Scholar] [CrossRef]
  39. Armenta, S.; Garrigues, S.; de la Guardia, M. Green Analytical Chemistry. TrAC Trends Anal. Chem. 2008, 27, 497–511. [Google Scholar] [CrossRef]
  40. Gu, Z.-Y.; Yang, C.-X.; Chang, N.; Yan, X.-P. Metal-Organic Frameworks for Analytical Chemistry: From Sample Collection to Chromatographic Separation. Acc. Chem. Res. 2012, 45, 734–745. [Google Scholar] [CrossRef]
  41. Lang, Q.; Wai, C.M. Supercritical Fluid Extraction in Herbal and Natural Product Studies—A Practical Review. Talanta 2001, 53, 771–782. [Google Scholar] [CrossRef]
  42. Pourmortazavi, S.M.; Hajimirsadeghi, S.S. Supercritical Fluid Extraction in Plant Essential and Volatile Oil Analysis. J. Chromatogr. A 2007, 1163, 2–24. [Google Scholar] [CrossRef] [PubMed]
  43. Xu, R.N.; Fan, L.; Rieser, M.J.; El-Shourbagy, T.A. Recent Advances in High-Throughput Quantitative Bioanalysis by LC–MS/MS. J. Pharm. Biomed. Anal. 2007, 44, 342–355. [Google Scholar] [CrossRef]
  44. Packer, N.H.; Lawson, M.A.; Jardine, D.R.; Redmond, J.W. A General Approach to Desalting Oligosaccharides Released from Glycoproteins. Glycoconj. J. 1998, 15, 737–747. [Google Scholar] [CrossRef]
  45. Ye, X.; Kuklenyik, Z.; Needham, L.L.; Calafat, A.M. Automated On-Line Column-Switching HPLC-MS/MS Method with Peak Focusing for the Determination of Nine Environmental Phenols in Urine. Anal. Chem. 2005, 77, 5407–5413. [Google Scholar] [CrossRef]
  46. Calafat, A.M.; Kuklenyik, Z.; Reidy, J.A.; Caudill, S.P.; Tully, J.S.; Needham, L.L. Serum Concentrations of 11 Polyfluoroalkyl Compounds in the U.S. Population: Data from the National Health and Nutrition Examination Survey (NHANES) 1999–2000. Environ. Sci. Technol. 2007, 41, 2237–2242. [Google Scholar] [CrossRef] [PubMed]
  47. Wu, L.; Wang, W.; Jing, P.; Chen, Y.; Zhan, F.; Shi, Y.; Li, T. Travel Mode Choice and Their Impacts on Environment—A Literature Review Based on Bibliometric and Content Analysis, 2000–2018. J. Clean. Prod. 2020, 249, 119391. [Google Scholar] [CrossRef]
  48. Chuang, K.-Y.; Huang, Y.-L.; Ho, Y.-S. A Bibliometric and Citation Analysis of Stroke-Related Research in Taiwan. Scientometrics 2007, 72, 201–212. [Google Scholar] [CrossRef]
  49. Wang, H.; Zhao, Q.; Song, W.; Xu, Y.; Zhang, X.; Zeng, Q.; Chen, H.; Ding, L.; Ren, N. High-Throughput Dynamic Microwave-Assisted Extraction on-Line Coupled with Solid-Phase Extraction for Analysis of Nicotine in Mushroom. Talanta 2011, 85, 743–748. [Google Scholar] [CrossRef] [PubMed]
  50. Viganó, J.; Sanches, V.L.; de Souza Mesquita, L.M.; de Souza, M.C.; da Silva, L.C.; Chaves, J.O.; Forster-Carneiro, T.; Rostagno, M.A. Comprehensive Analysis of Phenolic Compounds from Natural Products: Integrating Sample Preparation and Analysis. Anal. Chim. Acta 2021, 1178, 338845. [Google Scholar] [CrossRef]
  51. Chen, L.; Ding, L.; Jin, H.; Song, D.; Zhang, H.; Li, J.; Zhang, K.; Wang, Y.; Zhang, H. The Determination of Organochlorine Pesticides Based on Dynamic Microwave-Assisted Extraction Coupled with on-Line Solid-Phase Extraction of High-Performance Liquid Chromatography. Anal. Chim. Acta 2007, 589, 239–246. [Google Scholar] [CrossRef]
  52. Sánchez-Camargo, A.d.P.; Parada-Alfonso, F.; Ibáñez, E.; Cifuentes, A. On-Line Coupling of Supercritical Fluid Extraction and Chromatographic Techniques. J. Sep. Sci. 2017, 40, 213–227. [Google Scholar] [CrossRef]
  53. Hyötyläinen, T. Principles, Developments and Applications of on-Line Coupling of Extraction with Chromatography. J. Chromatogr. A 2007, 1153, 14–28. [Google Scholar] [CrossRef]
  54. Zoccali, M.; Giuffrida, D.; Salafia, F.; Rigano, F.; Dugo, P.; Casale, M.; Mondello, L. Apocarotenoids Profiling in Different Capsicum Species. Food Chem. 2021, 334, 127595. [Google Scholar] [CrossRef] [PubMed]
  55. Hamada, N.; Hashi, Y.; Yamaki, S.; Guo, Y.; Zhang, L.; Li, H.; Lin, J.-M. Construction of On-Line Supercritical Fluid Extraction with Reverse Phase Liquid Chromatography–Tandem Mass Spectrometry for the Determination of Capsaicin. Chin. Chem. Lett. 2019, 30, 99–102. [Google Scholar] [CrossRef]
  56. Giuffrida, D.; Zoccali, M.; Arigò, A.; Cacciola, F.; Roa, C.O.; Dugo, P.; Mondello, L. Comparison of Different Analytical Techniques for the Analysis of Carotenoids in Tamarillo (Solanum Betaceum Cav.). Arch. Biochem. Biophys. 2018, 646, 161–167. [Google Scholar] [CrossRef]
  57. Abrahamsson, V.; Jumaah, F.; Turner, C. Continuous Multicomponent Quantification during Supercritical Fluid Extraction Applied to Microalgae Using In-Line UV/Vis Absorption Spectroscopy and on-Line Evaporative Light Scattering Detection. J. Supercrit. Fluids 2018, 131, 157–165. [Google Scholar] [CrossRef]
  58. Liang, Y.; Liu, J.; Zhong, Q.; Shen, L.; Yao, J.; Huang, T.; Zhou, T. Determination of Major Aromatic Constituents in Vanilla Using an On-Line Supercritical Fluid Extraction Coupled with Supercritical Fluid Chromatography. J. Sep. Sci. 2018, 41, 1600–1609. [Google Scholar] [CrossRef]
  59. Zoccali, M.; Giuffrida, D.; Dugo, P.; Mondello, L. Direct Online Extraction and Determination by Supercritical Fluid Extraction with Chromatography and Mass Spectrometry of Targeted Carotenoids from Red Habanero Peppers (Capsicum Chinense Jacq.). J. Sep. Sci. 2017, 40, 3905–3913. [Google Scholar] [CrossRef]
  60. Abrahamsson, V.; Rodriguez-Meizoso, I.; Turner, C. Supercritical Fluid Extraction of Lipids from Linseed with On-Line Evaporative Light Scattering Detection. Anal. Chim. Acta. 2015, 853, 320–327. [Google Scholar] [CrossRef]
  61. Yamaguchi, T.; Kamezawa, K.; Iwaya, K.; Sato, Y.; Miyaji, T.; Bounoshita, M.; Tognarelli, D.; Saito, M. Analysis of Piperine in Peppers Using On-Line SFE-UHPLC with Photodiode Array Detection. Am. Lab. 2011, 43, 29–32. [Google Scholar]
  62. Zhang, J.; Zhang, L.; Duan, J.; Liang, Z.; Zhang, W.; Huo, Y.; Zhang, Y. On-Line Hyphenation of Supercritical Fluid Extraction and Two-Dimensional High Performance Liquid Chromatography-Atmospheric Pressure Chemical Ionization Tandem Mass Spectrometer for the Analysis of Ganoderma Lucidum. J. Sep. Sci. 2006, 29, 2514–2522. [Google Scholar] [CrossRef]
  63. Chen, T.-Q.; Zhao, X.-Y.; Wu, J.-Z.; Yu, D.-Y.; Wu, Y.-B. Supercritical Fluid CO2 Extraction, Simultaneous Determination of Components in Ultra-Fine Powder of Ganoderma Sinense by HPLC–ESI-MS Method. J. Taiwan Inst. Chem. Eng. 2011, 42, 428–434. [Google Scholar] [CrossRef]
  64. Juliasih, N.L.G.R.; Yuan, L.C.; Atsuta, Y.; Daimon, H. Development of Coupled Supercritical Fluid Extraction-High Performance Liquid Chromatography for Quinone Analysis in Activated Sludge. Sep. Sci. Technol. 2016, 51, 439–446. [Google Scholar] [CrossRef]
  65. Rissato, S.R.; Galhiane, M.S.; de Souza, A.G.; Apon, B.M. Development of a Supercritical Fluid Extraction Method for Simultaneous Determination of Organophosphorus, Organohalogen, Organonitrogen and Pyretroids Pesticides in Fruit and Vegetables and Its Comparison with a Conventional Method by GC-ECD and GC-MS. J. Braz. Chem. Soc. 2005, 16, 1038–1047. [Google Scholar] [CrossRef]
  66. Valverde, A.; Aguilera, A.; Rodriguez, M.; Brotons, M. Evaluation of a Multiresidue Method for Pesticides in Cereals Using Supercritical Fluid Extraction and Gas Chromatographic Detection. J. Environ. Sci. Health B 2009, 44, 204–213. [Google Scholar] [CrossRef] [PubMed]
  67. Yang, T.-J.; Tsai, F.-J.; Chen, C.-Y.; Yang, T.C.-C.; Lee, M.-R. Determination of Additives in Cosmetics by Supercritical Fluid Extraction On-Line Headspace Solid-Phase Microextraction Combined with Gas Chromatography–Mass Spectrometry. Anal. Chim. Acta 2010, 668, 188–194. [Google Scholar] [CrossRef] [PubMed]
  68. Hofstetter, R.; Fassauer, G.M.; Link, A. Supercritical Fluid Extraction (SFE) of Ketamine Metabolites from Dried Urine and on-Line Quantification by Supercritical Fluid Chromatography and Single Mass Detection (on-Line SFE–SFC–MS). J. Chromatogr. B 2018, 1076, 77–83. [Google Scholar] [CrossRef] [PubMed]
  69. Zoccali, M.; Giuffrida, D.; Salafia, F.; Giofrè, S.V.; Mondello, L. Carotenoids and Apocarotenoids Determination in Intact Human Blood Samples by Online Supercritical Fluid Extraction-Supercritical Fluid Chromatography-Tandem Mass Spectrometry. Anal. Chim. Acta 2018, 1032, 40–47. [Google Scholar] [CrossRef]
  70. Wicker, A.P.; Carlton, D.D.; Tanaka, K.; Nishimura, M.; Chen, V.; Ogura, T.; Hedgepeth, W.; Schug, K.A. On-Line Supercritical Fluid Extraction—Supercritical Fluid Chromatography-Mass Spectrometry of Polycyclic Aromatic Hydrocarbons in Soil. J. Chromatogr. B 2018, 1086, 82–88. [Google Scholar] [CrossRef]
  71. Suzuki, M.; Nishiumi, S.; Kobayashi, T.; Sakai, A.; Iwata, Y.; Uchikata, T.; Izumi, Y.; Azuma, T.; Bamba, T.; Yoshida, M. Use of On-Line Supercritical Fluid Extraction-Supercritical Fluid Chromatography/Tandem Mass Spectrometry to Analyze Disease Biomarkers in Dried Serum Spots Compared with Serum Analysis Using Liquid Chromatography/Tandem Mass Spectrometry. Rapid Commun. Mass Spectrom. 2017, 31, 886–894. [Google Scholar] [CrossRef]
  72. You, J.; Gao, S.; Jin, H.; Li, W.; Zhang, H.; Yu, A. On-Line Continuous Flow Ultrasonic Extraction Coupled with High Performance Liquid Chromatographic Separation for Determination of the Flavonoids from Root of Scutellaria Baicalensis Georgi. J. Chromatogr. A 2010, 1217, 1875–1881. [Google Scholar] [CrossRef]
  73. Kivilompolo, M.; Hyötyläinen, T. On-Line Coupled Dynamic Sonication-Assisted Extraction-Liquid Chromatography for the Determination of Phenolic Acids in Lamiaceae Herbs. J. Chromatogr. A 2009, 1216, 892–896. [Google Scholar] [CrossRef] [PubMed]
  74. Chen, L.; Jin, H.; Wang, L.; Sun, L.; Xu, H.; Ding, L.; Yu, A.; Zhang, H. Dynamic Ultrasound-Assisted Extraction Coupled on-Line with Solid Support Derivatization and High-Performance Liquid Chromatography for the Determination of Formaldehyde in Textiles. J. Chromatogr. A 2008, 1192, 89–94. [Google Scholar] [CrossRef] [PubMed]
  75. Valdez-Flores, C.; Cañizares-Macias, M.P. On-Line Dilution and Detection of Vainillin in Vanilla Extracts Obtained by Ultrasound. Food Chem. 2007, 105, 1201–1208. [Google Scholar] [CrossRef]
  76. Zhang, Y.; Liu, C.; Qi, Y.; Li, S.; Pan, Y.; Li, Y. Circulating Ultrasound-Assisted Extraction, Countercurrent Chromatography, and Liquid Chromatography for the Simultaneous Extraction, Isolation, and Analysis of the Constituents of Uncaria Tomentosa. J. Chromatogr. A 2015, 1388, 36–42. [Google Scholar] [CrossRef] [PubMed]
  77. Zhang, Y.; Liu, R.; Liu, C.; Li, S.; Tsao, R. Development of Ultrasound-Assisted Mixture Extraction and Online Extraction Solution Concentration Coupled with Countercurrent Chromatography for the Preparation of Pure Phytochemicals from Phellinus Vaninii. J. Chromatogr. B 2021, 1171, 122619. [Google Scholar] [CrossRef] [PubMed]
  78. Falkova, M.; Alexovič, M.; Pushina, M.; Bulatov, A.; Moskvin, L.; Andruch, V. Fully Automated On-Line Flow-Batch Based Ultrasound-Assisted Surfactant-Mediated Extraction and Determination of Anthraquinones in Medicinal Plants. Microchem. J. 2014, 116, 98–106. [Google Scholar] [CrossRef]
  79. Zhu, S.; Ma, C.; Fu, Q.; Hu, L.; Lou, Z.; Wang, H.; Tao, G. Application of Ionic Liquids in an Online Ultrasonic Assisted Extraction and Solid-Phase Trapping of Rhodiosin and Rhodionin from Rhodiola Rosea for UPLC. Chromatographia 2013, 76, 195–200. [Google Scholar] [CrossRef]
  80. Morales-Muñoz, S.; de Castro, M.D.L. Dynamic Ultrasound-Assisted Extraction of Colistin from Feeds with on-Line Pre-Column Derivatization and Liquid Chromatography-Fluorimetric Detection. J. Chromatogr. A 2005, 1066, 1–7. [Google Scholar] [CrossRef]
  81. Zhang, Y.; Liu, C.; Li, S.; Hou, W.; Tsao, R. Development of Ultrasound-Assisted Centrifugal Extraction and Online Solvent Concentration Coupled with Parallel Countercurrent Chromatography for the Preparation of Purified Phytochemicals: Application to Lycium Ruthenicum. Ind. Crops Prod. 2021, 162, 113266. [Google Scholar] [CrossRef]
  82. Yebra-Biurrun, M.C.; Moreno-Cid, A.; Cancela-Pérez, S. Fast On-Line Ultrasound-Assisted Extraction Coupled to a Flow Injection-Atomic Absorption Spectrometric System for Zinc Determination in Meat Samples. Talanta 2005, 66, 691–695. [Google Scholar] [CrossRef] [PubMed]
  83. Sanchez-Prado, L.; Garcia-Jares, C.; Dagnac, T.; Llompart, M. Microwave-Assisted Extraction of Emerging Pollutants in Environmental and Biological Samples before Chromatographic Determination. TrAC Trends Anal. Chem. 2015, 71, 119–143. [Google Scholar] [CrossRef]
  84. Wang, H.; Ding, J.; Ren, N. Recent Advances in Microwave-Assisted Extraction of Trace Organic Pollutants from Food and Environmental Samples. TrAC Trends Anal. Chem. 2016, 75, 197–208. [Google Scholar] [CrossRef]
  85. Gao, S.; Yu, W.; Yang, X.; Liu, Z.; Jia, Y.; Zhang, H. On-Line Ionic Liquid-Based Dynamic Microwave-Assisted Extraction-High Performance Liquid Chromatography for the Determination of Lipophilic Constituents in Root of Salvia Miltiorrhiza Bunge. J. Sep. Sci. 2012, 35, 2813–2821. [Google Scholar] [CrossRef]
  86. Wang, H.; Chen, L.; Xu, Y.; Zeng, Q.; Zhang, X.; Zhao, Q.; Ding, L. Dynamic Microwave-Assisted Extraction Coupled on-Line with Clean-up for Determination of Caffeine in Tea. LWT—Food Sci. Technol. 2011, 44, 1490–1495. [Google Scholar] [CrossRef]
  87. Chen, L.; Jin, H.; Ding, L.; Zhang, H.; Wang, X.; Wang, Z.; Li, J.; Qu, C.; Wang, Y.; Zhang, H. On-Line Coupling of Dynamic Microwave-Assisted Extraction with High-Performance Liquid Chromatography for Determination of Andrographolide and Dehydroandrographolide in Andrographis Paniculata Nees. J. Chromatogr. A 2007, 1140, 71–77. [Google Scholar] [CrossRef] [PubMed]
  88. Chen, L.; Ding, L.; Zhang, H.; Li, J.; Wang, Y.; Wang, X.; Qu, C.; Zhang, H. Dynamic Microwave-Assisted Extraction Coupled with on-Line Spectrophotometric Determination of Safflower Yellow in Flos Carthami. Anal. Chim. Acta 2006, 580, 75–82. [Google Scholar] [CrossRef]
  89. Tong, X.; Xiao, X.; Li, G. On-Line Coupling of Dynamic Microwave-Assisted Extraction with High-Speed Counter-Current Chromatography for Continuous Isolation of Nevadensin from Lyeicnotus Pauciflorus Maxim. J. Chromatogr. B 2011, 879, 2397–2402. [Google Scholar] [CrossRef] [PubMed]
  90. Pu, Y.; Wang, J.-X.; Wang, D.; Foster, N.R.; Chen, J.-F. Subcritical Water Processing for Nanopharmaceuticals. Chem. Eng. Process. 2019, 140, 36–42. [Google Scholar] [CrossRef]
  91. Thiruvenkadam, S.; Izhar, S.; Yoshida, H.; Danquah, M.K.; Harun, R. Process Application of Subcritical Water Extraction (SWE) for Algal Bio-Products and Biofuels Production. Appl. Energy 2015, 154, 815–828. [Google Scholar] [CrossRef]
  92. Souza, M.C.; Silva, L.C.; Chaves, J.O.; Salvador, M.P.; Sanches, V.L.; da Cunha, D.T.; Foster Carneiro, T.; Rostagno, M.A. Simultaneous Extraction and Separation of Compounds from Mate (Ilex Paraguariensis) Leaves by Pressurized Liquid Extraction Coupled with Solid-Phase Extraction and in-Line UV Detection. Food Chem. Mol. Sci. 2021, 2, 100008. [Google Scholar] [CrossRef]
  93. Taylor, B.M.; Thurbide, K.B. On-Line Coupling of a Micro-Pressurized Liquid Extraction Method to Liquid Chromatography Via Solid-Phase Trapping. Chromatographia 2020, 83, 1319–1327. [Google Scholar] [CrossRef]
  94. Souza, M.C.; Santos, M.P.; Sumere, B.R.; Silva, L.C.; Cunha, D.T.; Martínez, J.; Barbero, G.F.; Rostagno, M.A. Isolation of Gallic Acid, Caffeine and Flavonols from Black Tea by on-Line Coupling of Pressurized Liquid Extraction with an Adsorbent for the Production of Functional Bakery Products. LWT 2020, 117, 108661. [Google Scholar] [CrossRef]
  95. Qian, Z.-M.; Chen, L.; Wu, M.-Q.; Li, D.-Q. Rapid Screening and Characterization of Natural Antioxidants in Polygonum Viviparum by an On-Line System Integrating the Pressurised Liquid Micro-Extraction, HPLC-DAD-QTOF-MS/MS Analysis and Antioxidant Assay. J. Chromatogr. B 2020, 1137, 121926. [Google Scholar] [CrossRef]
  96. Song, Q.; Li, J.; Liu, X.; Zhang, Y.; Guo, L.; Jiang, Y.; Song, Y.; Tu, P. Home-Made Online Hyphenation of Pressurized Liquid Extraction, Turbulent Flow Chromatography, and High Performance Liquid Chromatography, Cistanche Deserticola as a Case Study. J. Chromatogr. A 2016, 1438, 189–197. [Google Scholar] [CrossRef] [PubMed]
  97. Li, B.; Yang, Y.; Gan, Y.; Eaton, C.D.; He, P.; Jones, A.D. On-Line Coupling of Subcritical Water Extraction with High-Performance Liquid Chromatography via Solid-Phase Trapping. J. Chromatogr. A 2000, 873, 175–184. [Google Scholar] [CrossRef]
  98. Crescenzi, C.; di Corcia, A.; Nazzari, M.; Samperi, R. Hot Phosphate-Buffered Water Extraction Coupled on-Line with Liquid Chromatography/Mass Spectrometry for Analyzing Contaminants in Soil. Anal. Chem. 2000, 72, 3050–3055. [Google Scholar] [CrossRef] [PubMed]
  99. Hyötyläinen, T.; Andersson, T.; Hartonen, K.; Kuosmanen, K.; Riekkola, M.-L. Pressurized Hot Water Extraction Coupled On-Line with LC−GC: Determination of Polyaromatic Hydrocarbons in Sediment. Anal. Chem. 2000, 72, 3070–3076. [Google Scholar] [CrossRef] [PubMed]
  100. Kuosmanen, K.; Hyötyläinen, T.; Hartonen, K.; Riekkola, M.-L. Analysis of Polycyclic Aromatic Hydrocarbons in Soil and Sediment with On-Line Coupled Pressurised Hot Water Extraction, Hollow Fibre Microporous Membrane Liquid-Liquid Extraction and Gas Chromatography. Analyst 2003, 128, 434–439. [Google Scholar] [CrossRef]
  101. Borisova, D.R.; Goncharova, E.N.; Statkus, M.A.; Tsisin, G.I. On-Line Solid-Phase Extraction and HPLC Determination of Phthalic Acid Monoesters Including Desorption with Subcritical Water. Mosc. Univ. Chem. Bull. 2015, 70, 237–241. [Google Scholar] [CrossRef]
  102. Murakami, T.; Kawasaki, T.; Takemura, A.; Fukutsu, N.; Kishi, N.; Kusu, F. Identification of Degradation Products in Loxoprofen Sodium Adhesive Tapes by Liquid Chromatography–Mass Spectrometry and Dynamic Pressurized Liquid Extraction–Solid-Phase Extraction Coupled to Liquid Chromatography–Nuclear Magnetic Resonance Spectroscopy. J. Chromatogr. A 2008, 1208, 164–174. [Google Scholar] [CrossRef]
  103. Morales-Muñoz, S.; Luque-García, J.L.; Luque de Castro, M.D. Static Extraction with Modified Pressurized Liquid and On-Line Fluorescence Monitoring: Independent Matrix Approach for the Removal of Polycyclic Aromatic Hydrocarbons from Environmental Solid Samples. J. Chromatogr. A 2002, 978, 49–57. [Google Scholar] [CrossRef]
Figure 1. Classification of coupling forms with the detection system.
Figure 1. Classification of coupling forms with the detection system.
Molecules 27 06272 g001
Figure 2. Evolution of the number of publications and main research areas. (A) Annual publications and (B) total publications.
Figure 2. Evolution of the number of publications and main research areas. (A) Annual publications and (B) total publications.
Molecules 27 06272 g002
Figure 3. Collaboration map among the top 30 most productive countries.
Figure 3. Collaboration map among the top 30 most productive countries.
Molecules 27 06272 g003
Figure 4. Simplified diagram of on-line coupling among the main extraction and analysis techniques.
Figure 4. Simplified diagram of on-line coupling among the main extraction and analysis techniques.
Molecules 27 06272 g004
Table 1. Top 10 journals ranked by number of publications.
Table 1. Top 10 journals ranked by number of publications.
RankJournalsCountryPublishing CompanyImpact FactorRecords% of 2353
1Journal of Chromatography ANetherlandsElsevier4.75937415.895
2TalantaEnglandElsevier6.0571456.162
3Journal of Chromatography BNetherlandsElsevier3.2051446.120
4Analytica Chimica ActaNetherlandsElsevier6.5581335.652
5Analytical ChemistryUSAACS Publications6.986883.740
6Analytical and Bioanalytical ChemistryGermanySpringer4.157773.272
6ChromatographiaGermanySpringer2.044773.272
8Journal of Pharmaceutical and Biomedical AnalysisNetherlandsElsevier3.935723.060
9ElectrophoresisGermanyWILEY3.535662.805
10Journal of Separation ScienceGermanyWILEY3.645612.592
The impact factor measures the average number of citations received in a particular year by papers published in the journal during the two preceding years. Journal impact factor (Clarivate Analytics, 2021) [36].
Table 2. Top 10 articles ranked by number of citations.
Table 2. Top 10 articles ranked by number of citations.
RankTitleJournalsCitationsArticle TypeReferences
1Phosphorus flame retardants: properties, production, environmental occurrence, toxicity and analysisChemosphere1424Review article[37]
2Solid-phase extraction: method development, sorbents, and coupling with liquid chromatographyJournal of Chromatography A835Review article[38]
3Green Analytical ChemistryTrends in Analytical Chemistry594Review article[39]
4Metal-Organic Frameworks for Analytical Chemistry: From Sample Collection to Chromatographic SeparationAccounts of Chemical Research548Review article[40]
5Supercritical fluid extraction in herbal and natural product studies—a practical reviewTalanta434Review article[41]
6Supercritical fluid extraction in plant essential and volatile oil analysisJournal of Chromatography A396Review article[42]
7Recent advances in high-throughput quantitative bioanalysis by LC-MS/MSJournal of Pharmaceutical and Biomedical Analysis373Review article[43]
8A general approach to desalting oligosaccharides released from glycoproteinsGlycoconjugate Journal365Research article[44]
9Automated online column-switching HPLC-MS/MS method with peak focusing for the determination of nine environmental phenols in urineAnalytical Chemistry324Research article[45]
10Serum concentrations of 11 polyfluoroalkyl compounds in the US population: Data from the National Health and Nutrition Examination Survey (NHANES) 1999–2000Environmental Science & Technology317Research article[46]
Table 3. Top 30 most frequent keywords (author keywords and keywords plus).
Table 3. Top 30 most frequent keywords (author keywords and keywords plus).
RankAuthor KeywordsOccurrencesRankKeywords PlusOccurrences
1Solid-phase extraction2661Solid-phase extraction671
2On-line solid-phase extraction1592High performance liquid-chromatography414
3Mass spectrometry1173Liquid-chromatography286
4Capillary electrophoresis1024Mass-spectrometry275
5Pesticides965Tandem mass-spectrometry214
6Liquid chromatography876Samples213
7On-line SPE827Gas-Chromatography209
8LC-MS/MS778Separation193
8HPLC779Water172
8Supercritical fluid extraction7710Metabolites144
8Water analysis7711Chromatography135
12Sample preparation7412Human plasma134
13Column Switching6313Urine114
14Urine6214Preconcentration112
15High performance liquid chromatography5715Microextraction111
16Environmental analysis5416Pesticides106
17Automation4517Polycyclic aromatic-hydrocarbons103
17Column liquid chromatography4518plasma102
19On-line preconcentration4219Identification100
20Preconcentration4020HPLC97
21Gas chromatography3621Extraction88
22Water3522Sample preparation85
23LC-MS3223Capillary-electrophoresis83
24On-line extraction3123Quantification83
25Water samples3025Supercritical-fluid extraction82
26Extraction2926Water samples74
26Plasma2926Waste-water74
26Monolithic column2928On-line72
29Human plasma2828Residues72
29Tandem mass spectrometry2830drugs70
Italics used for words present in the two columns of the table.
Table 4. Comprehensive report of SFE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
Table 4. Comprehensive report of SFE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
SampleCompounds of InterestCoupled TechniquesSolventsSFE Conditions (F; P; T)SFE Method (Static Mode)SFE Method (Dynamic Mode)SFC/LC MethodDetectorReferences
Chilli PeppersCarotenoids and apocarotenoidsSFE-SFC-
QqQ/MS
CO2 (A) CH3OH (B)2.0 mL/min; 150 bars; 80 °C0–3 min, 10% B3–4 min, 0% B4–6 min, 0% B; 6–21 min, 0–80% B; 21–22 min, 80–100% B; 22–24, 100% BAPCI-MS[54]
Green, yellow, and red bell peppersCapsaicinSFE-SPE-LC-MSCO2 (A) CH3OH (B)5.0 mL/min; 15 MPa; 50 °C0–4 min, 5% B4–8 min, 5% B0 min, 45% B; 0–10 min, 80% B; 10–12 min, 100% B; 12–13.5 min, 100% B; 15.5–13.6 min, 45% BESI-MS[55]
Yellow tamarillo fruitsApocarotenoids and carotenoidsSFE-SFC-
QqQ/MS
CO2 (A) CH3OH (B)2.0 mL/min; 150 bars; 80 °C0–3 min, 5% B3–4 min, 10% B4–6 min, 0% B; 6–14 min, 0–40% B; 14–16 min, 40% BAPCI-MS[56]
Chaenomelis FructusOleanoic acid and ursolic acidSFE-SFCCO2 (A) CH3OH (B)5.0 mL/min; 15 MPa; 35 °C0–1 min, 20% B1–8 min, 5% B0–10 min, 5–10% B; 10–14 min, 10% B; 14–16 min, 10–40% B; 16–20 min, 40% BPDA[16]
MicroalgaeCarotenoids, chlorophyll A, ergosterol, and total lipidsSFE-UV/Vis-
ELSD
CO2 (A) CH3CH2OH (B)1.5 mL/min; 15–30 MPa; 40–60 °C---UV/Vis ELSD[57]
Vanilla beansAromatic constituentsSFE-SFCCO2 (A)

CH3OH (B)
2.0 mL/min 10–20 MPa; 35–55 °C--0–13 min, 2–10% B; 13–17 min, 10–15% B; 17–18 min, 15% BPDA[58]
Red Habanero peppersCarotenoidsSFE-SFC-
QqQ/MS
CO2 (A) CH3OH (B)3.0 mL/min; 150 bars; 40–80 °C0–3 min, 10% B3–4 min, 0% B4–6 min, 0% B; 6–14 min, 0–40% B; 14–16 min, 40% BAPCI-MS[59]
LinseedLipidsSFE–ELSDCO2 (A)

CH3CH2OH (B)
1.5 mL/min 30 MPa; 80 °C---ELSD[60]
Table 5. Comprehensive report of UAE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
Table 5. Comprehensive report of UAE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
SampleCompounds of InterestCoupled TechniquesSolvents for UAEMobile Phase for LCUAE Conditions (F; P; T)Reference
Porous fungus, P. vaniniiPhytochemicalsUAE and on-line extraction.n-Hexane–ethyl acetate–acetonitrile–water (5.5:2.5:5.0:0.4, v/v/v) was used as the solvent systemelution procedure: 0–20 min, 45%–80% (acetonitrile), 65%–10% (water); flow rate: 0.4 mL/min500 W, 170 mL/min 40 °C[77]
Frangula alnus (cortex) and Rubia tinctorum (roots and rhizomes)AnthraquinonesUAE + spectrophotometricTriton X-100Non-applicable325 W, 35 kHz at 75 °C for 10 min[78]
Rhodiola roseaRhodiosinUAE+SPE coupled UPLCEthanol:water (95%)ACN-formic acid (0.1%, v/v): 0–8 min, 5–40%, acetonitrile; 8–15 min, 40–100% acetonitrile. The flow rate of 0.3 mL/min60 kHz, 360 W on the scale of 0–100[79]
Scutellaria baicalensis GeorgiFlavonoidsUAE-HPLCEthanol:water (60%)ACN-water with 0.1% phosphoric acid. The gradient conditions was 0–15 min, 20–30% ACN; 16–20 min, 30–50% ACN; 21–28 min, 50–20% CAN. The flow rate of 1 mL/min40 kHz, 150 W[72]
basil (Ocimum basilicum L.), oregano (Origanum vulgare L.), rosemary (Rosmarinus officinalis L.), sage (Salvia officinalis L.), spearmint (Mentha spicata L.) and thyme (Thymus vulgaris).Phenolic acidsUAE+SPE coupled on HPLCEthanol:water (60%)0 min 5% methanol, 2 min 5% methanol, 6 min 25% methanol, 13 min 40% methanol, 26 min 40% methanol. The flow rate of 1 mL/minFlow rate 0.25 mL/min, temperature 45 °C and extraction time 15 min.[73]
Textile fragmentsFormaldehydeUAE coupled on -HPLCWater4 mmol L−1 sodium dihydrogen phosphate in 50% ACN at a flow rate of 1.0 mL min−1.40 kHz. 100 and 800 W, 80 °C.[74]
Colistin in feed.colistin A and BUAE coupled with HPLC---[80]
Table 6. Comprehensive report of MAE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
Table 6. Comprehensive report of MAE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
SampleCompounds of InterestCoupled TechniquesSolventsMAE Conditions (F; P; T)LC/GC MethodDetectorReference
Salvia miltiorrhiza Bunge Lipophilic constituents (tanshin-one I, cryptotanshinone, and tanshinone IIA)DMAE-HPLC[C6MIM]Cl aqueous solution (A), Ethanol (B)1.6 mL/min; 180 Wmethanol-water (v/v, 81/19) and isocratic elution; 0.5 mL min−1; at 40 °C and injection volume of 20 μL.Photodiode-array detector (PAD)[85]
MushroomNicotineHTDMAE-
SPE
Water, elution solvent (methanol–ammonia, 95:5, v/v)2.0 mL/min; 1000 W20 mmol L−1 ammonium acetate solution (pH = 3) and methanol (80:20, v/v)); 1.0 mL min−1, at 30 °C and injection volume of 20 μL.UV detector monitoring at 260 nm[49]
TeaCaffeineDMAE coupled on-line with clean-upEthanol1.0 mL/min; 70 W30% methanol and 70% water; 1.0 mL min−1.UV detector monitoring at 270 nm[86]
Andrographis paniculata NeesAndrographolide and dehydroandrographolideDMAE-HPLCMethanol1.0 mL/min; 80 W65% aqueous methanol; 1.0 mL min−1 and injection volume of 20 μL.Photodiode-array detector (PAD)[87]
Grain samples, including wheat, rice, corn and beanOrganochlorine pesticidesDMAE–SPE–HPLC95% acetonitrile1.0 mL/min; 80 WMobile phase of 75% ACN aqueous solution; 1.0 mL min−1. ---[51]
Flos CarthamiSafflower yellowMAE-UV60% methanol1.0 mL/min; 80 W------[88]
Table 7. Comprehensive report of PLE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
Table 7. Comprehensive report of PLE systems coupled with on-line analysis systems for solid matrices from vegetable origin.
SampleCompounds of InterestCoupled TechniquesPLE Conditions (F; P; T)SolventsLC MethodDetectorReference
Yerba mate (Ilex paraguariensis)Alkaloids, phenolic acids and flavonoidsPLE-SPE-
HPLC
2.0 mL/min; 100 bars; 40–80 °CH2O (A) CH3CN (B)1 min, 10% B; 2 min, 20% B; 4 min, 30% B; 5 min, 90% B; 8 min, 10% BUV-Vis [92]
Strawberry and appleHerbicide 2-(3-chlorophenoxy) propionic acid (3-CPA)µPLE-SPE-
HPLC
1.0 mL/min; 30 bars; 150–160 °CH2O (A) CH3CN (B)70% A/30% B/0.1% Formic AcidUV-Vis [93]
Black teaGallic ccid, caffeine, and flavonolsPLE-SPE-
HPLC
2.0 mL/min; 100 bars; 40–80 °CH2O (A) CH3CN (B)0 min, (95% A); 1 min, (95% A); 3 min, (90% A); 7 min, (87.5% A); 9 min, (85% A); 10 min, (82% A); 18 min, (77% A); 20 min, (0% A); 22 min, (0% A); 23 min, (95% A)UV-Vis[94]
Dried root (Polygonum viviparum)AntioxidantsPLE-HPLC1.0 mL/min; 70 °CH2O (A) CH3CN (B)0–5 min, 0% B; 5–6 min, 5% B; 6–21 min, 15% B; 21–30 min, 20% B; 30–35 min, 80% B; 35–37 min, 0% BPDA[95]
Ginseng of the desert (Cistanche deserticola)Primary phenylethanoid glycosidesPLE–TFC–HPLC2.5 mL/min; 13 MPa; 70 °CH2O (A) CH3CN (B)0–3 min, 10% B; 3–10 min, 10–20% B; 10–25 min, 20–30% B; 25–35 min, 30–45% B; 35–40 min, 45–60% B; 40–45 min, 60–90% B; 45–48 min, 90% B; 48, 1–60 min, 10% BPDA[96]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Maciel-Silva, F.W.; Lachos-Perez, D.; Buller, L.S.; Sganzerla, W.G.; Pérez, M.; Rostagno, M.A.; Forster-Carneiro, T. Green Extraction Processes for Complex Samples from Vegetable Matrices Coupled with On-Line Detection System: A Critical Review. Molecules 2022, 27, 6272. https://doi.org/10.3390/molecules27196272

AMA Style

Maciel-Silva FW, Lachos-Perez D, Buller LS, Sganzerla WG, Pérez M, Rostagno MA, Forster-Carneiro T. Green Extraction Processes for Complex Samples from Vegetable Matrices Coupled with On-Line Detection System: A Critical Review. Molecules. 2022; 27(19):6272. https://doi.org/10.3390/molecules27196272

Chicago/Turabian Style

Maciel-Silva, Francisco W., Daniel Lachos-Perez, Luz Selene Buller, William G. Sganzerla, Montserrat Pérez, Mauricio A. Rostagno, and Tania Forster-Carneiro. 2022. "Green Extraction Processes for Complex Samples from Vegetable Matrices Coupled with On-Line Detection System: A Critical Review" Molecules 27, no. 19: 6272. https://doi.org/10.3390/molecules27196272

Article Metrics

Back to TopTop