Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (459)

Search Parameters:
Keywords = wind comfort

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
28 pages, 8519 KiB  
Article
Evaluating the Microclimatic Performance of Elevated Open Spaces for Outdoor Thermal Comfort in Cold Climate Zones
by Xuan Ma, Qian Luo, Fangxi Yan, Yibo Lei, Yuyang Lu, Haoyang Chen, Yuhuan Yang, Han Feng, Mengyuan Zhou, Hua Ding and Jingyuan Zhao
Buildings 2025, 15(15), 2777; https://doi.org/10.3390/buildings15152777 - 6 Aug 2025
Abstract
Improving outdoor thermal comfort is a critical objective in urban design, particularly in densely built urban environments. Elevated semi-open spaces—outdoor areas located beneath raised building structures—have been recognized for enhancing pedestrian comfort by improving airflow and shading. However, previous studies primarily focused on [...] Read more.
Improving outdoor thermal comfort is a critical objective in urban design, particularly in densely built urban environments. Elevated semi-open spaces—outdoor areas located beneath raised building structures—have been recognized for enhancing pedestrian comfort by improving airflow and shading. However, previous studies primarily focused on warm or temperate climates, leaving a significant research gap regarding their thermal performance in cold climate zones characterized by extreme seasonal variations. Specifically, few studies have investigated how these spaces perform under conditions typical of northern Chinese cities like Xi’an, which is explicitly classified within the Cold Climate Zone according to China’s national standard GB 50176-2016 and experiences both severe summer heat and cold winter conditions. To address this gap, we conducted field measurements and numerical simulations using the ENVI-met model (v5.0) to systematically evaluate the microclimatic performance of elevated ground-floor spaces in Xi’an. Key microclimatic parameters—including air temperature, mean radiant temperature, relative humidity, and wind velocity—were assessed during representative summer and winter conditions. Our findings indicate that the height of the elevated structure significantly affects outdoor thermal comfort, identifying an optimal elevated height range of 3.6–4.3 m to effectively balance summer cooling and winter sheltering needs. These results provide valuable design guidance for architects and planners aiming to enhance outdoor thermal environments in cold climate regions facing distinct seasonal extremes. Full article
37 pages, 7429 KiB  
Article
Study on the Influence of Window Size on the Thermal Comfort of Traditional One-Seal Dwellings (Yikeyin) in Kunming Under Natural Wind
by Yaoning Yang, Junfeng Yin, Jixiang Cai, Xinping Wang and Juncheng Zeng
Buildings 2025, 15(15), 2714; https://doi.org/10.3390/buildings15152714 - 1 Aug 2025
Viewed by 174
Abstract
Under the dual challenges of global energy crisis and climate change, the building sector, as a major carbon emitter consuming 33% of global primary energy, has seen its energy efficiency optimization become a critical pathway towards achieving carbon neutrality goals. The Window-to-Wall Ratio [...] Read more.
Under the dual challenges of global energy crisis and climate change, the building sector, as a major carbon emitter consuming 33% of global primary energy, has seen its energy efficiency optimization become a critical pathway towards achieving carbon neutrality goals. The Window-to-Wall Ratio (WWR), serving as a core parameter in building envelope design, directly influences building energy consumption, with its optimized design playing a decisive role in balancing natural daylighting, ventilation efficiency, and thermal comfort. This study focuses on the traditional One-Seal dwellings (Yikeyin) in Kunming, China, establishing a dynamic wind field-thermal environment coupled analysis framework to investigate the impact mechanism of window dimensions (WWR and aspect ratio) on indoor thermal comfort under natural wind conditions in transitional climate zones. Utilizing the Grasshopper platform integrated with Ladybug, Honeybee, and Butterfly plugins, we developed parametric models incorporating Kunming’s Energy Plus Weather meteorological data. EnergyPlus and OpenFOAM were employed, respectively, for building heat-moisture balance calculations and Computational Fluid Dynamic (CFD) simulations, with particular emphasis on analyzing the effects of varying WWR (0.05–0.20) on temperature-humidity, air velocity, and ventilation efficiency during typical winter and summer weeks. Key findings include, (1) in summer, the baseline scenario with WWR = 0.1 achieves a dynamic thermal-humidity balance (20.89–24.27 °C, 65.35–74.22%) through a “air-permeable but non-ventilative” strategy, though wing rooms show humidity-heat accumulation risks; increasing WWR to 0.15–0.2 enhances ventilation efficiency (2–3 times higher air changes) but causes a 4.5% humidity surge; (2) winter conditions with WWR ≥ 0.15 reduce wing room temperatures to 17.32 °C, approaching cold thresholds, while WWR = 0.05 mitigates heat loss but exacerbates humidity accumulation; (3) a symmetrical layout structurally constrains central ventilation, maintaining main halls air changes below one Air Change per Hour (ACH). The study proposes an optimized WWR range of 0.1–0.15 combined with asymmetric window opening strategies, providing quantitative guidance for validating the scientific value of vernacular architectural wisdom in low-energy design. Full article
Show Figures

Figure 1

31 pages, 5669 KiB  
Article
Research on the Influence of the Parameters of the “AO-Shaped” Skywell of Traditional Huizhou Residential Houses on the Indoor Wind Environment
by Wenjia Pan and Bin Cheng
Buildings 2025, 15(15), 2713; https://doi.org/10.3390/buildings15152713 - 1 Aug 2025
Viewed by 165
Abstract
This study was conducted in the context of China’s latest “double carbon” policy. The objective of this study was twofold: firstly, to examine the characteristics of traditional Chinese residential skywell; and secondly, to investigate and develop climate-adaptive technologies for these structures. To this [...] Read more.
This study was conducted in the context of China’s latest “double carbon” policy. The objective of this study was twofold: firstly, to examine the characteristics of traditional Chinese residential skywell; and secondly, to investigate and develop climate-adaptive technologies for these structures. To this end, a study was conducted on the Huizhou skywell architecture in China. Firstly, we obtained a large amount of basic data, such as traditional buildings and skywell parameters in Huizhou through field research and on-site mapping. Second, we combined a large number of parameters and typical cases to analyze the data and determine a more scientifically typical model of Huizhou architecture and experimental coverage of skywell data. Different shapes and sizes of skywell were formed by changing the combination of skywell length and width, and the indoor wind environments of these skywell dwelling models were simulated one by one using PHOENIX (v2016) software. Finally, the data obtained from these simulations are analyzed using the variable control method, and the simulated indoor wind environments of skywells under different scale combinations in terms of skywell length, width, and length–width coupling effects are summarized and compared. The following conclusions were drawn: (1) The length of the skywell has a certain effect on all indoor wind environments, and the variation in indoor wind speed is smallest when the length of the skywell is 7.5 m. When selecting the design size of the skywell, the length of the skywell can be increased accordingly. (2) The width of the skywell for the indoor wind environment is divided into two cases, when the length of the skywell is less than 3.75 m, increasing the width of the skywell will make the indoor wind environment more unstable. However, when the length of the skywell is greater than 3.75 m, the width of the skywell is positively related to the comfort of the indoor wind environment. (3) The area of the skywell should not be too large, usually between 11.25 m2 and 18.75 m2. A slender skywell is more likely to provide a comfortable indoor wind environment. (4) After extensive evaluation, we found that the comfort of the indoor wind environment is high when the width of the skywell is 2 m. The optimum dimensions for the ventilation performance of the skywell are 7.5 m in length and 2 m in width. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

19 pages, 5847 KiB  
Article
Parametric Analysis of Rammed Earth Walls in the Context of the Thermal Protection of Environmentally Friendly Buildings
by Piotr Kosiński, Wojciech Jabłoński and Krystian Patyna
Sustainability 2025, 17(15), 6886; https://doi.org/10.3390/su17156886 - 29 Jul 2025
Viewed by 273
Abstract
Rammed earth (RE), a traditional material aligned with circular economy (CE) principles, has been gaining renewed interest in contemporary construction due to its low environmental impact and compatibility with sustainable building strategies. Though not a modern invention, it is being reintroduced in response [...] Read more.
Rammed earth (RE), a traditional material aligned with circular economy (CE) principles, has been gaining renewed interest in contemporary construction due to its low environmental impact and compatibility with sustainable building strategies. Though not a modern invention, it is being reintroduced in response to the increasingly strict European Union (EU) regulations on carbon footprint, life cycle performance, and thermal efficiency. RE walls offer multiple benefits, including humidity regulation, thermal mass, plasticity, and structural strength. This study also draws attention to their often-overlooked ability to mitigate indoor overheating. To preserve these advantages while enhancing thermal performance, this study explores insulation strategies that maintain the vapor-permeable nature of RE walls. A parametric analysis using Delphin 6.1 software was conducted to simulate heat and moisture transfer in two main configurations: (a) a ventilated system insulated with mineral wool (MW), wood wool (WW), hemp shives (HS), and cellulose fiber (CF), protected by a jute mat wind barrier and finished with wooden cladding; (b) a closed system using MW and WW panels finished with lime plaster. In both cases, clay plaster was applied on the interior side. The results reveal distinct hygrothermal behavior among the insulation types and confirm the potential of natural, low-processed materials to support thermal comfort, moisture buffering, and the alignment with CE objectives in energy-efficient construction. Full article
Show Figures

Figure 1

30 pages, 78202 KiB  
Article
Climate-Adaptive Architecture: Analysis of the Wei Family Compound’s Thermal–Ventilation Environment in Ganzhou, China
by Xiaolong Tao, Xin Liang and Wenjia Liu
Buildings 2025, 15(15), 2673; https://doi.org/10.3390/buildings15152673 - 29 Jul 2025
Viewed by 462
Abstract
Sustainable building design is significantly impacted by the local climate response knowledge ingrained in traditional architecture. However, its integration and dissemination with contemporary green technologies are limited by the absence of a comprehensive quantitative analysis of the regulation of its humid and temperature [...] Read more.
Sustainable building design is significantly impacted by the local climate response knowledge ingrained in traditional architecture. However, its integration and dissemination with contemporary green technologies are limited by the absence of a comprehensive quantitative analysis of the regulation of its humid and temperature environment. The Ganzhou Wei family compound from China’s wind–heat environmental regulation systems are examined in this study. We statistically evaluate the synergy between spatial morphology, material qualities, and microclimate using field data with Thsware and Ecotect software in a multiscale simulation framework. The findings indicate that the compound’s special design greatly controls the thermal and wind conditions. Cold alleyways and courtyards work together to maximize thermal environment regulation and encourage natural ventilation. According to quantitative studies, courtyards with particular depths (1–4 m) and height-to-width ratios (e.g., 1:1) reduce wind speed loss. A cool alley (5:1 height–width ratio) creates a dynamic wind–speed–temperature–humidity balance by lowering summer daytime temperatures by 2.5 °C. It also serves as a “cold source area” that moderates temperatures in the surrounding area by up to 2.1 °C. This study suggests a quantitative correlation model based on “spatial morphology–material performance–microclimate response,” which offers a technical route for historic building conservation renovation and green renewal, as well as a scientific foundation for traditional buildings to maintain thermal comfort under low energy consumption. Although based on a specific geographical case, the innovative analytical methods and strategies of this study are of great theoretical and practical significance for promoting the modernization and transformation of traditional architecture, low-carbon city construction, and sustainable building design. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

19 pages, 3568 KiB  
Article
Heat Impact of Urban Sprawl: How the Spatial Composition of Residential Suburbs Impacts Summer Air Temperatures and Thermal Comfort
by Mahmuda Sharmin, Manuel Esperon-Rodriguez, Lauren Clackson, Sebastian Pfautsch and Sally A. Power
Atmosphere 2025, 16(8), 899; https://doi.org/10.3390/atmos16080899 - 23 Jul 2025
Viewed by 282
Abstract
Urban residential design influences local microclimates and human thermal comfort. This study combines empirical microclimate data with remotely sensed data on tree canopy cover, housing lot size, surface permeability, and roof colour to examine thermal differences between three newly built and three established [...] Read more.
Urban residential design influences local microclimates and human thermal comfort. This study combines empirical microclimate data with remotely sensed data on tree canopy cover, housing lot size, surface permeability, and roof colour to examine thermal differences between three newly built and three established residential suburbs in Western Sydney, Australia. Established areas featured larger housing lots and mature street trees, while newly developed suburbs had smaller lots and limited vegetation cover. Microclimate data were collected during summer 2021 under both heatwave and non-heatwave conditions in full sun, measuring air temperature, relative humidity, wind speed, and wet-bulb globe temperature (WBGT) as an index of heat stress. Daily maximum air temperatures reached 42.7 °C in new suburbs, compared to 39.3 °C in established ones (p < 0.001). WBGT levels during heatwaves were in the “extreme caution” category in new suburbs, while remaining in the “caution” range in established ones. These findings highlight the benefits of larger green spaces, permeable surfaces, and lighter roof colours in the context of urban heat exposure. Maintaining mature trees and avoiding dark roofs can significantly reduce summer heat and improve outdoor thermal comfort across a range of conditions. Results of this work can inform bottom-up approaches to climate-responsive urban design where informed homeowners can influence development outcomes. Full article
(This article belongs to the Section Biometeorology and Bioclimatology)
Show Figures

Figure 1

27 pages, 2691 KiB  
Article
Airflow Dynamics for Micro-Wind Environment Optimization and Human Comfort Improvement: Roadshow Design for Theater Stage Spaces
by Yiheng Liu, Menglong Zhang, Wenyang Han, Yufei He, Chang Yi, Yin Zhang and Jin Li
Sensors 2025, 25(14), 4456; https://doi.org/10.3390/s25144456 - 17 Jul 2025
Viewed by 227
Abstract
The optimization of ventilation strategies in high-ceiling theater stage spaces is crucial for improving thermal comfort and energy efficiency. This study addresses the challenge of uneven temperature distribution and airflow stagnation in stage environments by employing computational fluid dynamics (CFD) simulations to evaluate [...] Read more.
The optimization of ventilation strategies in high-ceiling theater stage spaces is crucial for improving thermal comfort and energy efficiency. This study addresses the challenge of uneven temperature distribution and airflow stagnation in stage environments by employing computational fluid dynamics (CFD) simulations to evaluate the effectiveness of different ventilation modes, including natural, mechanical, and hybrid systems. Six airflow organization scenarios were designed based on modifications to structural layout, equipment settings, and mechanical disturbances (e.g., fan integration). Key evaluation indicators such as temperature uniformity coefficient, airflow velocity, and exhaust efficiency were used to assess performance. The results show that a multi-dimensional optimization approach combining spatial adjustments and mechanical disturbances significantly reduced the average temperature from 26 °C to 23 °C and the temperature uniformity coefficient from 2.79 to 1.49. This study contributes a comprehensive design strategy for stage ventilation that improves comfort while minimizing energy consumption, offering practical implications for performance space design and HVAC system integration. Full article
(This article belongs to the Special Issue IoT and Ubiquitous Computing for Smart Building)
Show Figures

Figure 1

35 pages, 2895 KiB  
Review
Ventilated Facades for Low-Carbon Buildings: A Review
by Pinar Mert Cuce and Erdem Cuce
Processes 2025, 13(7), 2275; https://doi.org/10.3390/pr13072275 - 17 Jul 2025
Viewed by 643
Abstract
The construction sector presently consumes about 40% of global energy and generates 36% of CO2 emissions, making facade retrofits a priority for decarbonising buildings. This review clarifies how ventilated facades (VFs), wall assemblies that interpose a ventilated air cavity between outer cladding [...] Read more.
The construction sector presently consumes about 40% of global energy and generates 36% of CO2 emissions, making facade retrofits a priority for decarbonising buildings. This review clarifies how ventilated facades (VFs), wall assemblies that interpose a ventilated air cavity between outer cladding and the insulated structure, address that challenge. First, the paper categorises VFs by structural configuration, ventilation strategy and functional control into four principal families: double-skin, rainscreen, hybrid/adaptive and active–passive systems, with further extensions such as BIPV, PCM and green-wall integrations that couple energy generation or storage with envelope performance. Heat-transfer analysis shows that the cavity interrupts conductive paths, promotes buoyancy- or wind-driven convection, and curtails radiative exchange. Key design parameters, including cavity depth, vent-area ratio, airflow velocity and surface emissivity, govern this balance, while hybrid ventilation offers the most excellent peak-load mitigation with modest energy input. A synthesis of simulation and field studies indicates that properly detailed VFs reduce envelope cooling loads by 20–55% across diverse climates and cut winter heating demand by 10–20% when vents are seasonally managed or coupled with heat-recovery devices. These thermal benefits translate into steadier interior surface temperatures, lower radiant asymmetry and fewer drafts, thereby expanding the hours occupants remain within comfort bands without mechanical conditioning. Climate-responsive guidance emerges in tropical and arid regions, favouring highly ventilated, low-absorptance cladding; temperate and continental zones gain from adaptive vents, movable insulation or PCM layers; multi-skin adaptive facades promise balanced year-round savings by re-configuring in real time. Overall, the review demonstrates that VFs constitute a versatile, passive-plus platform for low-carbon buildings, simultaneously enhancing energy efficiency, durability and indoor comfort. Future advances in smart controls, bio-based materials and integrated energy-recovery systems are poised to unlock further performance gains and accelerate the sector’s transition to net-zero. Emerging multifunctional materials such as phase-change composites, nanostructured coatings, and perovskite-integrated systems also show promise in enhancing facade adaptability and energy responsiveness. Full article
(This article belongs to the Special Issue Sustainable Development of Energy and Environment in Buildings)
Show Figures

Figure 1

28 pages, 4067 KiB  
Article
Comprehensive Assessment of Indoor Thermal in Vernacular Building Using Machine Learning Model with GAN-Based Data Imputation: A Case of Aceh Region, Indonesia
by Muslimsyah Muslimsyah, Safwan Safwan and Andri Novandri
Buildings 2025, 15(14), 2448; https://doi.org/10.3390/buildings15142448 - 11 Jul 2025
Viewed by 370
Abstract
This study introduces a predictive model for estimating indoor room temperatures in vernacular building using external environmental factors such as air temperature, humidity, sunshine duration, and wind speed. The dataset was sourced from the Meteorology, Climatology, and Geophysics Agency and supplemented with direct [...] Read more.
This study introduces a predictive model for estimating indoor room temperatures in vernacular building using external environmental factors such as air temperature, humidity, sunshine duration, and wind speed. The dataset was sourced from the Meteorology, Climatology, and Geophysics Agency and supplemented with direct measurements collected from four rooms within a vernacular building in Aceh Province, Indonesia. A Generative Adversarial Network (GAN)-based imputation technique was implemented to address missing data during preprocessing. The prediction model adopts a hybrid framework that integrates Multiple Linear Regression (MLR) and Artificial Neural Networks (ANNs), with both models optimized using Support Vector Regression (SVR) to better capture the nonlinear dynamics between inputs and outputs. The evaluation results show that the ANN-SVR model achieved the lowest average MAE¯ and RMSE¯ values, at 0.164 and 0.218, respectively, and the highest average R¯ and R2¯ values, at 0.785 and 0.618. Evaluation results indicate that the ANN-SVR model consistently achieved the lowest error rates and the highest correlation coefficients across all four rooms, identifying it as the most effective model for forecasting indoor thermal conditions. These results validate the combined use of ANN-SVR for prediction and GAN for preprocessing as a powerful strategy to enhance data quality and model performance. The findings offer a scientific basis for architectural planning to improve thermal comfort in vernacular buildings such as the Rumoh Aceh. Full article
(This article belongs to the Special Issue Thermal Environment in Buildings: Innovations and Safety Perspectives)
Show Figures

Figure 1

29 pages, 4726 KiB  
Article
Adaptive Pendulum-Tuned Mass Damper Based on Adjustable-Length Cable for Skyscraper Vibration Control
by Krzysztof Twardoch, Kacper Górski, Rafał Kwiatkowski, Kamil Jaśkielewicz and Bogumił Chiliński
Sustainability 2025, 17(14), 6301; https://doi.org/10.3390/su17146301 - 9 Jul 2025
Viewed by 474
Abstract
The dynamic control of vibrations in skyscrapers is a critical consideration in sustainable building design, particularly in response to environmental excitations such as wind impact or seismic activity. Effective vibration neutralisation plays a crucial role in providing the safety of high-rise buildings. This [...] Read more.
The dynamic control of vibrations in skyscrapers is a critical consideration in sustainable building design, particularly in response to environmental excitations such as wind impact or seismic activity. Effective vibration neutralisation plays a crucial role in providing the safety of high-rise buildings. This research introduces an innovative concept for an active vibration damper that operates based on fluid dynamic transport to adaptively alter a skyscraper’s natural frequency, thereby counteracting resonant vibrations. A distinctive feature of this system is an adjustable-length cable mechanism, allowing for the dynamic modification of the pendulum’s effective length in real time. The structure, based on cable length adjustment, enables the PTMD to precisely tune its natural frequency to variable excitation conditions, thereby improving damping during transient or resonance phenomena of the building’s dynamic behaviour. A comprehensive mathematical model based on Lagrangian mechanics outlines the governing equations for this system, capturing the interactions between pendulum motion, fluid flow, and the damping forces necessary to maintain stability. Simulation analyses examine the role of initial excitation frequency and variable damping coefficients, revealing critical insights into optimal damper performance under varied structural conditions. The findings indicate that the proposed pendulum damper effectively mitigates resonance risks, paving the way for sustainable skyscraper design through enhanced structural adaptability and resilience. This adaptive PTMD, featuring an adjustable-length cable, provides a solution for creating safe and energy-efficient skyscraper designs, aligning with sustainable architectural practices and advancing future trends in vibration management technology. The study presented in this article supports the development of modern skyscraper design, with a focus on dynamic vibration control for sustainability and structural safety. It combines advanced numerical modelling, data-driven control algorithms, and experimental validation. From a sustainability perspective, the proposed PTMD system reduces the need for oversized structural components by providing adaptive, efficient damping, thereby lowering material consumption and embedded carbon. Through dynamically retuning structural stiffness and mass, the proposed PTMD enhances resilience and energy efficiency in skyscrapers, lowers lifetime energy use associated with passive damping devices, and enhances occupant comfort. This aligns with global sustainability objectives and new-generation building standards. Full article
Show Figures

Figure 1

19 pages, 3206 KiB  
Article
Research on BIM Technology of Green Building Based on GBSWARE Software
by Hongmei Yin, Jun Liu, Min Liu and Xiaoyu Li
Buildings 2025, 15(13), 2297; https://doi.org/10.3390/buildings15132297 - 30 Jun 2025
Viewed by 293
Abstract
Against the background of the global concern for environmental protection and the prevalence of the green building concept, the requirements for building design are increasing, as are the technological content and functional requirements. Meanwhile, the urgency to address challenges related to the ecological [...] Read more.
Against the background of the global concern for environmental protection and the prevalence of the green building concept, the requirements for building design are increasing, as are the technological content and functional requirements. Meanwhile, the urgency to address challenges related to the ecological environment and performance requirements has become increasingly pronounced. Taking a dormitory building in China as an example. Autodesk Revit 2018 software is employed in this study to establish a building information modeling (BIM). Green building software (GBSWARE) simulates and analyzes outdoor wind environment, indoor thermal comfort, calculates building energy conservation, does daylighting analysis, and calculates building daylighting. Although the building’s energy-saving design aligns with the requirements, the lighting and indoor thermal comfort of the rooms do not meet the standards. Additionally, the outdoor wind environment has problems with the wind zone and a wind speed amplification coefficient that surpasses the limit. The thermal environment within the residential building fails to satisfy the requirements. This study leverages a BIM-based model for multifaceted applications, integrating tailored retrofit strategies that align with the building’s inherent characteristics and detailed analyses of its components. By harnessing the building’s energy-saving potential, it enhances energy use efficiency, offering a valuable reference for the conceptual design of green buildings and energy-efficient retrofits. Full article
Show Figures

Figure 1

27 pages, 12277 KiB  
Article
Quantifying Landscape Effects on Urban Park Thermal Environments Using ENVI-Met and 3D Grid Profile Analysis
by Dongyang Yan, Liang Xu, Qifan Wang, Jing Feng and Xixi Wu
Forests 2025, 16(7), 1085; https://doi.org/10.3390/f16071085 - 30 Jun 2025
Viewed by 499
Abstract
Blue–green infrastructure is widely recognized for mitigating the urban heat island effect. However, most existing ENVI-met 5.6.1 studies focus on average thermal conditions and overlook fine-scale spatial gradients. This study investigates the urban park in Luoyang City by integrating high-resolution 3D ENVI-met simulations, [...] Read more.
Blue–green infrastructure is widely recognized for mitigating the urban heat island effect. However, most existing ENVI-met 5.6.1 studies focus on average thermal conditions and overlook fine-scale spatial gradients. This study investigates the urban park in Luoyang City by integrating high-resolution 3D ENVI-met simulations, multi-source data, and field measurements to quantify thermal gradients between park interiors and surrounding built-up areas. A midline cut-off approach was applied to extract horizontal and vertical thermal profiles. The results show that (1) temperature and physiological equivalent temperature (PET) differences are most pronounced at park edges and transition zones, where vegetation and water bodies serve as natural cooling buffers; (2) urban form indicators, especially the building coverage and open space ratio, significantly impact wind speed and the PET, with greenery improving thermal comfort via shading and evapotranspiration, while impervious surfaces intensify heat stress; (3) the park exhibits a distinct cold island effect, with the average PET in the core area up to 12.3 °C lower than in adjacent built-up zones. The effective cooling distance, which is identified through buffer-based zonal statistics, rapidly attenuates within approximately 200 m from the park boundary. These findings offer a novel spatial perspective on thermal regulation mechanisms of urban landscapes and provide quantitative evidence to guide the design of climate-resilient green infrastructure. Full article
(This article belongs to the Special Issue Designing Urban Green Spaces in a Changing Climate)
Show Figures

Figure 1

25 pages, 34285 KiB  
Article
Optimizing Public Space Quality in High-Density Old Districts of Asian Megacities: Thermal Environment Analysis of Shenzhen’s Urban Fringe
by Jie Ren, Xiaohui Xu and Jielong Jiang
Buildings 2025, 15(13), 2166; https://doi.org/10.3390/buildings15132166 - 21 Jun 2025
Viewed by 342
Abstract
High density old districts at the urban fringes of Asian megacities, such as Shenzhen, face significant thermal challenges due to dense building clusters, limited airflow, and heat retention. This study adopts an integrated approach combining Phoenics wind simulation, geographic information system (GIS) modeling, [...] Read more.
High density old districts at the urban fringes of Asian megacities, such as Shenzhen, face significant thermal challenges due to dense building clusters, limited airflow, and heat retention. This study adopts an integrated approach combining Phoenics wind simulation, geographic information system (GIS) modeling, and spatial prototype analysis to assess and optimize the wind and thermal environments in these urban areas. It investigates how spatial configurations, including building density, height distribution, orientation, and green space integration, influence wind flow and thermal comfort. The results demonstrate that optimized spatial arrangements, including reduced building density, height adjustments, and strategic landscape design, improve ventilation and temperature regulation. Comparative analyses of different spatial prototypes reveal that radial configurations effectively channel external winds into the urban core, enhancing internal airflow, whereas rectangular layouts create wind shadows that hinder ventilation. Adjustments to building façades and vertical arrangements further mitigate pedestrian-level heat accumulation. Interventions in public spaces, including green roofs and vertical greening, offer cooling benefits and mitigate urban heat island effects. This study underscores the importance of aligning urban design with natural wind flow and offers a framework for sustainable landscape and architectural strategies in high-density, heat-prone environments. The findings offer valuable insights for urban planners and policymakers seeking sustainable development in similar megacities. Full article
(This article belongs to the Section Architectural Design, Urban Science, and Real Estate)
Show Figures

Figure 1

21 pages, 3571 KiB  
Article
An Experimental Study of Wind-Driven Ventilation with Double Skin Facade During Transition Seasons
by Guoqing He, Zhewen Fan, Yuan Meng, Linfeng Yao and Changqing Ye
Energies 2025, 18(13), 3249; https://doi.org/10.3390/en18133249 - 21 Jun 2025
Viewed by 350
Abstract
Double skin facade (DSF) is an energy-efficient solution for glazing facades. However, previous studies have reported inconsistent findings regarding thermal comfort in naturally ventilated DSF buildings. To examine this issue, this study evaluated airflow velocities in naturally ventilated DSF buildings during transition seasons [...] Read more.
Double skin facade (DSF) is an energy-efficient solution for glazing facades. However, previous studies have reported inconsistent findings regarding thermal comfort in naturally ventilated DSF buildings. To examine this issue, this study evaluated airflow velocities in naturally ventilated DSF buildings during transition seasons through a comparative study approach. A full-scale box-type DSF room and a traditional window-wall room were simultaneously monitored in a laboratory building under real climatic conditions, with indoor environmental parameters recorded for 10 days. Airflow sensation surveys complemented the physical measurements to evaluate perceived comfort. The results showed that the DSF room consistently exhibited lower air velocities (≤0.2 m/s) compared to the traditional room, demonstrating minimal response to wind conditions related to its small openings (opening ratio of 4.7%) and increased flow resistance from the dual-layer structure of the DSF. Under unfavorable wind conditions, the DSF room demonstrated higher ventilation rates due to the enhanced stack effect. However, this advantage had a negligible effect on the thermal comfort vote for the indoor temperature range (26 °C to 28 °C). These findings highlight the climate-dependent performance of DSFs: while advantageous for thermal comfort in cooler climates, they may lead to reduced thermal comfort in warm and hot climates due to low indoor airflow velocities. Future work could include the optimization of DSF opening configurations to enhance wind-driven ventilation while maintaining stack ventilation benefits. Full article
(This article belongs to the Special Issue Energy Efficiency and Energy Performance in Buildings—2nd Edition)
Show Figures

Figure 1

36 pages, 15003 KiB  
Article
Underground Space and Climate Synergy Wind–Heat Environmental Response in Cold Zones
by Lufeng Nie, Heng Liu, Jiuxin Wang, Shuai Tong and Xiang Ji
Buildings 2025, 15(13), 2151; https://doi.org/10.3390/buildings15132151 - 20 Jun 2025
Viewed by 456
Abstract
Underground spaces offer significant potential for sustainable urban development, particularly in cold climate regions where surface thermal fluctuations are extreme. However, optimizing the wind–heat environmental performance of such spaces remains insufficiently explored, especially in relation to spatial morphology. This study addresses this gap [...] Read more.
Underground spaces offer significant potential for sustainable urban development, particularly in cold climate regions where surface thermal fluctuations are extreme. However, optimizing the wind–heat environmental performance of such spaces remains insufficiently explored, especially in relation to spatial morphology. This study addresses this gap by investigating how underground spatial configurations influence thermal comfort and ventilation efficiency. Six representative spatial prototypes—fully enclosed, single-side open, double-side open, central atrium, wind tower, and earth kiln—were constructed based on common underground design typologies. Computational fluid dynamics (CFD) simulations were conducted to evaluate airflow patterns and thermal responses under winter and summer conditions, incorporating relevant geotechnical properties into the boundary setup. The results indicate that deeper burial depths enhance thermal stability, while central atrium and wind tower prototypes offer the most balanced performance in both ventilation and heat regulation. These findings provide valuable design guidance for climate-responsive underground developments and contribute to the interdisciplinary integration of building physics, spatial design, and geotechnical engineering. Full article
Show Figures

Figure 1

Back to TopTop