Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (66)

Search Parameters:
Keywords = third harmonic distortion

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
30 pages, 10206 KB  
Article
Evaluation and Improvement of Image Aesthetics Quality via Composition and Similarity
by Xinyu Cui, Guoqing Tu, Guoying Wang, Senjun Zhang and Lufeng Mo
Sensors 2025, 25(18), 5919; https://doi.org/10.3390/s25185919 - 22 Sep 2025
Viewed by 484
Abstract
The evaluation and enhancement of image aesthetics play a pivotal role in the development of visual media, impacting fields including photography, design, and computer vision. Composition, a key factor shaping visual aesthetics, significantly influences an image’s vividness and expressiveness. However, existing image optimization [...] Read more.
The evaluation and enhancement of image aesthetics play a pivotal role in the development of visual media, impacting fields including photography, design, and computer vision. Composition, a key factor shaping visual aesthetics, significantly influences an image’s vividness and expressiveness. However, existing image optimization methods face practical challenges: compression-induced distortion, imprecise object extraction, and cropping-caused unnatural proportions or content loss. To tackle these issues, this paper proposes an image aesthetic evaluation with composition and similarity (IACS) method that harmonizes composition aesthetics and image similarity through a unified function. When evaluating composition aesthetics, the method calculates the distance between the main semantic line (or salient object) and the nearest rule-of-thirds line or central line. For images featuring prominent semantic lines, a modified Hough transform is utilized to detect the main semantic line, while for images containing salient objects, a salient object detection method based on luminance channel salience features (LCSF) is applied to determine the salient object region. In evaluating similarity, edge similarity measured by the Canny operator is combined with the structural similarity index (SSIM). Furthermore, we introduce a Framework for Image Aesthetic Evaluation with Composition and Similarity-Based Optimization (FIACSO), which uses semantic segmentation and generative adversarial networks (GANs) to optimize composition while preserving the original content. Compared with prior approaches, the proposed method improves both the aesthetic appeal and fidelity of optimized images. Subjective evaluation involving 30 participants further confirms that FIACSO outperforms existing methods in overall aesthetics, compositional harmony, and content integrity. Beyond methodological contributions, this study also offers practical value: it supports photographers in refining image composition without losing context, assists designers in creating balanced layouts with minimal distortion, and provides computational tools to enhance the efficiency and quality of visual media production. Full article
(This article belongs to the Special Issue Recent Innovations in Computational Imaging and Sensing)
Show Figures

Figure 1

13 pages, 3362 KB  
Article
Gate-Induced Static and Dynamic Nonlinearity Characteristics of Bilayer Graphene Field-Effect Transistors (Bi-GFETs)
by Varun Kumar Kakar, Munindra and Pankaj Kumar Pal
Micromachines 2025, 16(9), 1031; https://doi.org/10.3390/mi16091031 - 9 Sep 2025
Viewed by 672
Abstract
In this study, the nonlinearity characteristics of bilayer graphene field-effect transistors (Bi-GFETs) are analyzed by using a small-signal equivalent circuit. The static nonlinearity is determined by applying mathematical operation on the drain current equation of Bi-GFETs. Furthermore, the closed expressions for the second- [...] Read more.
In this study, the nonlinearity characteristics of bilayer graphene field-effect transistors (Bi-GFETs) are analyzed by using a small-signal equivalent circuit. The static nonlinearity is determined by applying mathematical operation on the drain current equation of Bi-GFETs. Furthermore, the closed expressions for the second- and third-order harmonic distortion (HD) and the intermodulation (IM) distortion of the second- and third-order for Bi-GFETs are analyzed graphically. Dynamic nonlinearity is studied and illustrated in the results by examining the input and output characteristics; i.e., the drain current versus the negative drain to the source voltage and the transfer characteristic curve at various gate voltages controlled by both the top gate as well as the back gate. The characteristic behavior of the gate voltage in Bi-GFETs at short channel lengths is observed and compared; that is, the characteristic curves exhibits strong nonlinearity, with a low power point with some kinks at high gate biasing and a constant linear region at low gate biasing. The quantitative values of the second-order harmonic distortion (HD) and intermodulation distortion (IM) of the proposed analytical model are −40 dB and −45 dB. Quantitative and qualitative outcomes of the characteristics of Bi-GFETs are compared with existing experimental data, which is available in the literature. Full article
Show Figures

Figure 1

20 pages, 5833 KB  
Article
Power Factor Adaptive DPWM Control Strategy for T-Type Three-Level Inverters
by Jialiang Tian, Yingying Xu, Mingxia Xu, Zhenjiang Liu and Yuchi Zhou
Energies 2025, 18(17), 4574; https://doi.org/10.3390/en18174574 - 28 Aug 2025
Viewed by 543
Abstract
With the widespread application of multilevel inverters, device losses have become a critical area of research. A key limitation of conventional three-level discontinuous pulse width modulation (DPWM) strategies is their inability to maintain switching device clamping during the peak intervals of the load [...] Read more.
With the widespread application of multilevel inverters, device losses have become a critical area of research. A key limitation of conventional three-level discontinuous pulse width modulation (DPWM) strategies is their inability to maintain switching device clamping during the peak intervals of the load current, especially under varying load power factor conditions, thereby reducing switching losses. This paper proposes an improved three-level power factor adaptive DPWM (PFA-DPWM) strategy that minimizes switching losses by clamping the power devices during the one-third fundamental period of maximum load current. First, a unified mathematical model of DPWM strategies is established. Theoretical analysis demonstrates that phase disposition (PD) carrier modulation for three-level inverter exhibits superior line voltage harmonic characteristics. Based on this, a theoretical comparison of switching losses and harmonic distortion for various DPWM schemes is conducted. The proposed PFA-DPWM control strategy has the minimum switching loss without compromising harmonic performance. The efficacy and validity of the proposed strategy are confirmed by comprehensive simulation and experimental results. Full article
(This article belongs to the Special Issue Advanced Power Electronics Technology: 2nd Edition)
Show Figures

Figure 1

21 pages, 11484 KB  
Article
Analytical Investigation of Primary Waveform Distortion Effect on Magnetic Flux Density in the Magnetic Core of Inductive Current Transformer and Its Transformation Accuracy
by Michal Kaczmarek and Kacper Blus
Sensors 2025, 25(15), 4837; https://doi.org/10.3390/s25154837 - 6 Aug 2025
Cited by 1 | Viewed by 512
Abstract
This paper analyzes how distortion in the primary current waveform affects the magnetic flux density in the magnetic core of an inductive current transformer and its transformation accuracy. Keeping the primary current’s RMS value constant, it studies the impact of changes in the [...] Read more.
This paper analyzes how distortion in the primary current waveform affects the magnetic flux density in the magnetic core of an inductive current transformer and its transformation accuracy. Keeping the primary current’s RMS value constant, it studies the impact of changes in the RMS values and phase angles of low-order harmonics on the core’s flux density and the values of current error and phase displacement of their transformation. The distorted current waveforms, resulting flux density, and hysteresis loops are examined to identify the operating conditions of the inductive current transformer. This study also highlights the strong influence of low-order harmonics and the diminishing effect of higher-frequency harmonics on the magnetic flux density in its magnetic core, e.g., third, fifth, and seventh higher harmonics may cause an increase in magnetic flux density in the magnetic core of the inductive current transformer in relation to that obtained for a sinusoidal current with a frequency of 50 Hz by about 8.5%, while with additional second, fourth, and sixth harmonics, the increase may reach about 23%. Therefore, the testing procedure should consider not only the load impedance and the RMS values of the primary current but also its harmonic content, including the RMS values of individual harmonics and their phase angles. Full article
(This article belongs to the Special Issue Condition Monitoring of Electrical Equipment Within Power Systems)
Show Figures

Figure 1

20 pages, 7725 KB  
Article
Harmonic Distortion Peculiarities of High-Frequency SiGe HBT Power Cells for Radar Front End and Wireless Communication
by Paulius Sakalas and Anindya Mukherjee
Electronics 2025, 14(15), 2984; https://doi.org/10.3390/electronics14152984 - 26 Jul 2025
Viewed by 588
Abstract
High-frequency (h. f.) harmonic distortion (HD) of advanced SiGe heterojunction bipolar transistor (HBT)-based power cells (PwCs), featuring optimized metallization interconnections between individual HBTs, was investigated. Single tone input power (Pin) excitations at 1, 2, 5, and 10 GHz frequencies were [...] Read more.
High-frequency (h. f.) harmonic distortion (HD) of advanced SiGe heterojunction bipolar transistor (HBT)-based power cells (PwCs), featuring optimized metallization interconnections between individual HBTs, was investigated. Single tone input power (Pin) excitations at 1, 2, 5, and 10 GHz frequencies were employed. The output power (Pout) of the fundamental tone and its harmonics were analyzed in both the frequency and time domains. A rapid increase in the third harmonic of Pout was observed at input powers exceeding −8 dBm for a fundamental frequency of 10 GHz in two different PwC technologies. This increase in the third harmonic was analyzed in terms of nonlinear current waveforms, the nonlinearity of the HBT p-n junction diffusion capacitances, substrate current behavior versus Pin, and avalanche multiplication current. To assess the RF power performance of the PwCs, scalar and vectorial load-pull (LP) measurements were conducted and analyzed. Under matched conditions, the SiGe PwCs demonstrated good linearity, particularly at high frequencies. The key power performance of the PwCs was measured and simulated as follows: input power 1 dB compression point (Pin_1dB) of −3 dBm, transducer power gain (GT) of 15 dB, and power added efficiency (PAE) of 50% at 30 GHz. All measured data were corroborated with simulations using the compact model HiCuM L2. Full article
Show Figures

Figure 1

19 pages, 3698 KB  
Article
Multi-Plane Virtual Vector-Based Anti-Disturbance Model Predictive Fault-Tolerant Control for Electric Agricultural Equipment Applications
by Hengrui Cao, Konghao Xu, Li Zhang, Zhongqiu Liu, Ziyang Wang and Haijun Fu
Energies 2025, 18(14), 3857; https://doi.org/10.3390/en18143857 - 20 Jul 2025
Viewed by 405
Abstract
This paper proposes an anti-disturbance model predictive fault-tolerance control strategy for open-circuit faults of five-phase flux intensifying fault-tolerant interior permanent magnet (FIFT-IPM) motors. This strategy is applicable to electric agricultural equipment that has an open winding failure. Due to the rich third-harmonic back [...] Read more.
This paper proposes an anti-disturbance model predictive fault-tolerance control strategy for open-circuit faults of five-phase flux intensifying fault-tolerant interior permanent magnet (FIFT-IPM) motors. This strategy is applicable to electric agricultural equipment that has an open winding failure. Due to the rich third-harmonic back electromotive force (EMF) content of five-phase FIFT-IPM motors, the existing model predictive current fault-tolerant control algorithms fail to effectively track fundamental and third-harmonic currents. This results in high harmonic distortion in the phase current. Hence, this paper innovatively proposes a multi-plane virtual vector model predictive fault-tolerant control strategy that can achieve rapid and effective control of both the fundamental and harmonic planes while ensuring good dynamic stability performance. Additionally, considering that electric agricultural equipment is usually in a multi-disturbance working environment, this paper introduces an adaptive gain sliding-mode disturbance observer. This observer estimates complex disturbances and feeds them back into the control system, which possesses good resistance to complex disturbances. Finally, the feasibility and effectiveness of the proposed control strategy are verified by experimental results. Full article
Show Figures

Figure 1

29 pages, 8083 KB  
Article
DC-Link Voltage Stabilization and Capacitor Size Reduction in Active Neutral-Point-Clamped Inverters Using an Advanced Control Method
by Ahmet Yuksel, Ibrahim Sefa and Necmi Altin
Energies 2025, 18(12), 3143; https://doi.org/10.3390/en18123143 - 15 Jun 2025
Cited by 1 | Viewed by 1369
Abstract
This study examines the impact of midpoint voltage fluctuations on the performance of multilevel converters and proposes an advanced control strategy to reduce the required DC bus capacitance while maintaining system stability. The research demonstrates that active voltage imbalance control in active neutral-point-clamped [...] Read more.
This study examines the impact of midpoint voltage fluctuations on the performance of multilevel converters and proposes an advanced control strategy to reduce the required DC bus capacitance while maintaining system stability. The research demonstrates that active voltage imbalance control in active neutral-point-clamped (ANPC) topologies allows for stable operation with significantly reduced capacitor values. A hybrid control approach, combining fuzzy logic control and third-harmonic injection PWM (THIPWM), is developed to enhance voltage balancing, and modulation techniques are systematically optimized. Both simulation and experimental analyses confirm the efficacy of the proposed method, which achieves superior voltage regulation compared to conventional PI-based control schemes. Specifically, experimental results show a reduction in peak-to-peak DC-link voltage fluctuation from 116 V to just 4 V, and the phase current THD is reduced from 3.6% to 0.8%. The results indicate a substantial reduction in voltage fluctuations, contributing to a total harmonic distortion (THD) as low as 0.8%. Furthermore, the proposed strategy facilitates an approximate 26-fold decrease in DC bus capacitor size without compromising system stability. The reduction in capacitance not only lowers the overall system costs and hardware complexity but also improves reliability. The inverter was tested at a rated power of 62.5 kW using 0.3 mF capacitors instead of the theoretically required 7.8 mF. This work advances power electronics by presenting an efficient voltage balancing methodology, offering a cost-effective and robust solution for multilevel converter applications. The findings are validated through comprehensive simulations and experimental tests, ensuring practical applicability. Full article
Show Figures

Figure 1

33 pages, 10838 KB  
Article
A Novel Control Method for Current Waveform Reshaping and Transient Stability Enhancement of Grid-Forming Converters Considering Non-Ideal Grid Conditions
by Tengkai Yu, Jifeng Liang, Shiyang Rong, Zhipeng Shu, Cunyue Pan and Yingyu Liang
Energies 2025, 18(11), 2834; https://doi.org/10.3390/en18112834 - 29 May 2025
Viewed by 534
Abstract
The proliferation of next-generation renewable energy systems has driven widespread adoption of electronic devices and nonlinear loads, causing grid distortion that degrades waveform quality in grid-forming (GFM) converters. Additionally, unbalanced grid faults exacerbate overcurrent risks and transient stability challenges when employing conventional virtual [...] Read more.
The proliferation of next-generation renewable energy systems has driven widespread adoption of electronic devices and nonlinear loads, causing grid distortion that degrades waveform quality in grid-forming (GFM) converters. Additionally, unbalanced grid faults exacerbate overcurrent risks and transient stability challenges when employing conventional virtual impedance strategies. While existing studies have separately examined these challenges, few have comprehensively addressed non-ideal grid conditions. To bridge this gap, a novel control strategy is proposed that reshapes the output current waveforms and enhances transient stability in GFM converters under such conditions. First, a sliding mode controller with an improved composite reaching law to achieve rapid reference tracking while eliminating chattering is designed. Second, a multi-quasi-resonance controller incorporating phase compensation is introduced to suppress harmonic distortion in the converter output current. Third, an individual-phase fuzzy adaptive virtual impedance strategy dynamically reshapes the current amplitude during unbalanced faults and improves the system’s transient stability. Validated through PSCAD/EMTDC simulations and hardware-in-the-loop experiments, the proposed strategy demonstrates superior transient stability and fault ride-through capability compared to state-of-the-art methods, ensuring reliable GFM converter operation under severe harmonic and unbalanced grid conditions. Full article
(This article belongs to the Special Issue Technology for Analysis and Control of Power Quality)
Show Figures

Figure 1

14 pages, 3568 KB  
Article
A 0.3 V Current Differencing Buffered Amplifier and Its Application in Current-Mode Third-Order Low-Pass Filters
by Fabian Khateb, Montree Kumngern and Tomasz Kulej
Appl. Sci. 2025, 15(10), 5740; https://doi.org/10.3390/app15105740 - 21 May 2025
Viewed by 667
Abstract
This paper introduces an innovative low-voltage, low-power current differencing buffered amplifier (CDBA). The proposed CDBA utilizes a bulk-driven MOS transistor operating in the subthreshold region, allowing it to function effectively at low supply voltages while minimizing power consumption, making it suitable for sensor [...] Read more.
This paper introduces an innovative low-voltage, low-power current differencing buffered amplifier (CDBA). The proposed CDBA utilizes a bulk-driven MOS transistor operating in the subthreshold region, allowing it to function effectively at low supply voltages while minimizing power consumption, making it suitable for sensor and biomedical applications. To demonstrate the performance of the proposed CDBA, it is incorporated into the design of a current-mode, third-order low-pass filter that is specifically tailored for bio-sensing applications. Both the CDBA and the low-pass filter are designed and simulated in Cadence Virtuoso using the TSMC 0.18 µm CMOS process. The CDBA operates at a supply voltage of 0.3 V, consuming 170 nW of power, while the third-order low-pass filter achieves a dynamic range of 57.2 dB with a total harmonic distortion (THD) of 1%. Full article
Show Figures

Figure 1

13 pages, 6171 KB  
Article
A Study on the Device Topology and Control Strategy of a Hybrid Three-Port Photovoltaic Energy Storage Grid-Connected Converter
by Chen Shi and Shuqing Wang
Electronics 2025, 14(10), 1966; https://doi.org/10.3390/electronics14101966 - 12 May 2025
Viewed by 572
Abstract
A grid-connected converter is the interface between renewable energy power generation systems, such as solar power generation, wind power, hydropower, etc., and the power grid, responsible for the stable and efficient transmission of electric energy generated by renewable energy power generation systems to [...] Read more.
A grid-connected converter is the interface between renewable energy power generation systems, such as solar power generation, wind power, hydropower, etc., and the power grid, responsible for the stable and efficient transmission of electric energy generated by renewable energy power generation systems to the grid. In order to realize local access for distributed photovoltaic power generation devices and energy storage devices, a composite three-port converter has the advantages of small size, low cost and high power density compared with a combined three-port converter. In view of the current problems of the existing compound three-port (AC/DC/DC) converters, such as DC and AC circulating current in current composite three-port converters and the harmonic control problem, the proposed compound three-port topology consists of a full-bridge inverter with six switching tubes, a zigzag transformer, two sets of filter inductors and two filter capacitors. Among them, the power frequency transformer adopts the zigzag connection method, which can effectively restrain the AC circulation and eliminate the DC magnetic flux of the iron core while introducing the third port. Firstly, the principle of AC/DC and DC/DC power conversion in the composite three-port topology is analyzed, which has higher efficiency than other topologies. Secondly, the topology control strategy is analyzed, and a two-loop hybrid current control method with improved current loop is proposed. When the DC-side voltage fluctuates, the DC offset of the battery can effectively improve the stability of the network side. Through the MATLAB/Simulink simulation experiment platform, the high efficiency of energy conversion and stable grid-connected operation characteristics are verified. Finally, the experiment of integrating into the power grid was carried out. Experiments were used to verify the effectiveness and feasibility of the proposed topology and strategy. The experimental results show that Total Harmonic Distortion (THD) can be controlled below 3%. Full article
Show Figures

Figure 1

28 pages, 14318 KB  
Article
A Novel Voltage–Current Characteristic Model for Understanding of Electric Arc Furnace Behavior Using Experimental Data and Grey Wolf Optimization Algorithm
by Mustafa Şeker, Emre Ünsal, Ahmet Aksoz and Mahir Dursun
Appl. Sci. 2025, 15(7), 4005; https://doi.org/10.3390/app15074005 - 5 Apr 2025
Cited by 1 | Viewed by 1146
Abstract
The control of nonlinear systems cannot be effectively achieved using linear mathematical methods. This paper introduces a novel mathematical model to characterize the voltage–current (V–I) characteristics of the electric arc furnace (EAF) melting process, incorporating experimental field data for validation. The proposed model [...] Read more.
The control of nonlinear systems cannot be effectively achieved using linear mathematical methods. This paper introduces a novel mathematical model to characterize the voltage–current (V–I) characteristics of the electric arc furnace (EAF) melting process, incorporating experimental field data for validation. The proposed model integrates polynomial curve fitting, the modified Heidler function, and double S-curves, with the grey wolf optimization (GWO) algorithm applied for parameter optimization, enhancing accuracy in predicting arc dynamics. The performance of the model is compared against the exponential, hyperbolic, exponential–hyperbolic, and nonlinear resistance models, as well as real-time measurement data, to assess its effectiveness. The results show that the proposed model significantly reduces voltage and current harmonic distortion compared to existing models. Specifically, the total harmonic distortion (THD) for voltage is reduced to 2.34%, closely matching the real-time measured value of 2.30%. Similarly, in the current spectrum, the proposed model achieves a significant reduction in third harmonic distortion and a THD of 11.40%, compared to 13.76% in real-time measurements. Consequently, a more precise characterization of the EAF behavior enables more effective mitigation of harmonics and vibrations, enhancing the stability and power quality of the electrical networks to which they are connected. Full article
Show Figures

Figure 1

16 pages, 1422 KB  
Article
Limitations and Performance Analysis of Spherical Sector Harmonics for Sound Field Processing
by Hanwen Bi, Shaoheng Xu, Fei Ma, Thushara D. Abhayapala and Prasanga N. Samarasinghe
Appl. Sci. 2024, 14(22), 10633; https://doi.org/10.3390/app142210633 - 18 Nov 2024
Viewed by 1212
Abstract
Developing spherical sector harmonics (SSHs) benefits sound field decomposition and analysis over spherical sector regions. Although SSHs demonstrate potential in the field of spatial audio, a comprehensive investigation into their properties and performance is absent. This paper seeks to close this gap by [...] Read more.
Developing spherical sector harmonics (SSHs) benefits sound field decomposition and analysis over spherical sector regions. Although SSHs demonstrate potential in the field of spatial audio, a comprehensive investigation into their properties and performance is absent. This paper seeks to close this gap by revealing three key limitations of SSHs and exploring their performance in two aspects: sector sound field radial extrapolation and sector sound field decomposition and reconstruction. First, SSHs are not solutions to the Helmholtz equation, which is their main limitation. Then, due to the violation of the Helmholtz equation, SSHs lack the ability to conduct sound field radial extrapolation, especially for interior cases. Third, when using SSHs to decompose and reconstruct a sound field, the shifted associated Legendre polynomials and scaled exponential function in SSHs result in severe distortion around the edge of the sector region. In light of these three limitations, the future implementation of SSHs should focus on processing and analyzing the measurement sector region without any extrapolation process, and the measurement region should be larger than the target sector region. Full article
(This article belongs to the Special Issue Spatial Audio and Sound Design)
Show Figures

Figure 1

13 pages, 4990 KB  
Article
A Sinusoidal Current Generator IC with 0.04% THD for Bio-Impedance Spectroscopy Using a Digital ΔΣ Modulator and FIR Filter
by Soohyun Yun and Joonsung Bae
Electronics 2024, 13(22), 4450; https://doi.org/10.3390/electronics13224450 - 13 Nov 2024
Viewed by 1542
Abstract
This paper presents a highly efficient, low-power, compact mixed-signal sinusoidal current generator (CG) integrated circuit (IC) designed for bioelectrical impedance spectroscopy (BIS) with low total harmonic distortion (THD). The proposed system employs a 9-bit sine wave lookup table (LUT) which is simplified to [...] Read more.
This paper presents a highly efficient, low-power, compact mixed-signal sinusoidal current generator (CG) integrated circuit (IC) designed for bioelectrical impedance spectroscopy (BIS) with low total harmonic distortion (THD). The proposed system employs a 9-bit sine wave lookup table (LUT) which is simplified to a 4-bit data stream through a third-order digital delta–sigma modulator (ΔΣM). Unlike conventional analog low-pass filters (LPF), which statically limit bandwidth, the finite impulse response (FIR) filter attenuates high-frequency noise according to the operating frequency, allowing the frequency range of the sinusoidal signal to vary. Additionally, the output of the FIR filter is applied to a 6-bit capacitive digital-to-analog converter (CDAC) with data-weighted averaging (DWA), enabling dynamic capacitor matching and seamless interfacing. The sinusoidal CG IC, fabricated using a 65 nm CMOS process, produces a 5 μA amplitude and operates over a wide frequency range of 0.6 to 20 kHz. This highly synthesizable CG achieves a THD of 0.04%, consumes 19.2 μW of power, and occupies an area of 0.0798 mm2. These attributes make the CG IC highly suitable for compact, low-power bio-impedance applications. Full article
(This article belongs to the Special Issue CMOS Integrated Circuits Design)
Show Figures

Figure 1

13 pages, 8324 KB  
Article
Cable Insulation Defect Prediction Based on Harmonic Anomaly Feature Analysis
by Yuli Wang, Haisong Xu, Anzhe Wang, Kaiwen Huang, Ge Wang, Xu Lu and Daning Zhang
Electronics 2024, 13(19), 3807; https://doi.org/10.3390/electronics13193807 - 26 Sep 2024
Cited by 4 | Viewed by 1616
Abstract
With the increasing demand for power supply reliability, online monitoring techniques for cable health condition assessments are gaining more attention. Most prevailing techniques lack the sensitivity needed to detect minor insulation defects. A new monitoring technique based on the harmonic anomaly feature analysis [...] Read more.
With the increasing demand for power supply reliability, online monitoring techniques for cable health condition assessments are gaining more attention. Most prevailing techniques lack the sensitivity needed to detect minor insulation defects. A new monitoring technique based on the harmonic anomaly feature analysis of the shield-to-ground current is introduced in this paper. The sensor installation and data acquisition are convenient and intrinsically safe, which makes it a preferred online monitoring technique. This study focuses on the single-core 10 kV distribution cable type. The research work includes the theoretical analysis of the cable defect’s impact on the current harmonic features, which are then demonstrated by simulation and lab experiments. It has been found that cable insulation defects cause magnetic field distortion, which introduces various harmonic current components, principally, the third-, fifth-, and seventh-order harmonic. The harmonic anomaly features are load current-, defect type-, and aging time-dependent. The K-means algorithm was selected as the data analysis algorithm and was used to achieve insulation defect prediction. The research outcome establishes a solid basis for the field application of the shield-to-ground harmonic current monitoring technique. Full article
(This article belongs to the Special Issue Polyphase Insulation and Discharge in High-Voltage Technology)
Show Figures

Figure 1

18 pages, 1264 KB  
Article
Chernobyl Disaster Optimizer-Based Optimal Integration of Hybrid Photovoltaic Systems and Network Reconfiguration for Reliable and Quality Power Supply to Nuclear Research Reactors
by Sobha Rani Penubarthi, Radha Rani Korrapati, Varaprasad Janamala, Chaitanya Nimmagadda, Arigela Satya Veerendra and Srividya Ravindrakumar
Modelling 2024, 5(3), 1268-1285; https://doi.org/10.3390/modelling5030065 - 13 Sep 2024
Cited by 3 | Viewed by 1853
Abstract
In view of the complexity and importance of nuclear research reactor (NRR) installations, it is imperative to uphold high standards of reliability and quality in the electricity being supplied to them. In this paper, the performance of low-voltage (LV) distribution feeders integrated with [...] Read more.
In view of the complexity and importance of nuclear research reactor (NRR) installations, it is imperative to uphold high standards of reliability and quality in the electricity being supplied to them. In this paper, the performance of low-voltage (LV) distribution feeders integrated with NRRs is improved in terms of reduced distribution loss, improved voltage profile, and reduced greenhouse gas (GHG) emissions by determining the optimal location and size of photovoltaic (PV) systems. In the second stage, the power quality of the feeder is optimized by reducing the total harmonic distortion (THD) by optimally allocating D-STATCOM units. In the third and fourth stages, the reliability and resilience aspects of the feeder are optimized using optimal network reconfiguration (ONR) and by integrating an energy storage system (ESS). To solve the non-linear complex optimization problems at all these stages, an efficient meta-heuristic Chernobyl disaster optimizer (CDO) is proposed. Simulations are performed on a modified IEEE 33-bus feeder considering the non-linear characteristics of NRRs, variability of the feeder loading profile, and PV variability. The study reveals that the proposed methodology can significantly improve the service requirements of NRRs for attaining sustainable research activities. Full article
Show Figures

Figure 1

Back to TopTop