Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (104)

Search Parameters:
Keywords = superconducting quantum interference devices (SQUIDs)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
30 pages, 1235 KB  
Review
Recent Advances in Magnetic Polymer Nanocomposites for Water Purification Applications
by Sonia Azzaza, Amel Delimi, Hana Ferkous, Kamilia Madi, Amdjed Abdennouri, Mohammed Zighed, Khadidja Otmane Rachedi, Mohammed Rabeh Makhlouf, Imane Ghouafria, Hichem Tahraoui and Abdeltif Amrane
Water 2026, 18(15), 1874; https://doi.org/10.3390/w18151874 - 1 Aug 2026
Viewed by 291
Abstract
Magnetic polymer nanocomposites (MPNCs) have attracted considerable attention as advanced multifunctional materials for water purification due to their high adsorption capacity, magnetic recoverability, and excellent reusability. This review presents a comprehensive overview of recent developments in the synthesis, characterization, and environmental applications of [...] Read more.
Magnetic polymer nanocomposites (MPNCs) have attracted considerable attention as advanced multifunctional materials for water purification due to their high adsorption capacity, magnetic recoverability, and excellent reusability. This review presents a comprehensive overview of recent developments in the synthesis, characterization, and environmental applications of MPNCs for wastewater treatment. Particular emphasis is placed on the principal synthesis strategies, including in situ and ex situ approaches, and their influence on nanoparticle dispersion, interfacial interactions, and the physicochemical properties of the resulting nanocomposites. The review covers the most widely investigated magnetic nanomaterials, such as Fe3O4, γ-Fe2O3, CoFe2O4, ZnFe2O4, and other ferrites, incorporated into natural and synthetic polymer matrices including chitosan, cellulose, alginate, polyaniline, polypyrrole, poly(vinyl alcohol), and polystyrene. Advanced characterization techniques, including X-ray diffraction (XRD), scanning and transmission electron microscopy (SEM/TEM), Fourier-transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), thermogravimetric analysis (TGA), vibrating sample magnetometry (VSM), and superconducting quantum interference device (SQUID) measurements, are discussed to evaluate the structural, chemical, thermal, and magnetic properties of these hybrid materials. The adsorption performance and underlying mechanisms of MPNCs for the removal of heavy metals, dyes, pharmaceutical compounds, organic pollutants, and oil contaminants are critically analyzed, highlighting the roles of polymer functionalization, nanocomposite architecture, and magnetic separation in enhancing treatment efficiency and reusability. In addition, the contribution of density functional theory (DFT) to understanding adsorption mechanisms and guiding the rational design of high-performance adsorbents is reviewed. Finally, current challenges and future perspectives, including green synthesis, multifunctional and stimuli-responsive materials, scalable manufacturing, and industrial implementation, are discussed. This review provides a comprehensive framework for the design and development of next-generation magnetic polymer nanocomposites for sustainable water remediation applications. Full article
Show Figures

Figure 1

19 pages, 1946 KB  
Article
Environment-Driven Synthetic Baseline Analysis and Optimization in Joint Measurement OPM-MEG Arrays
by Wenli Wang, Jianxin Yang, Weinan Xu, Fuzhi Cao, Nan An, Zhenfeng Gao, Min Xiang and Wen Li
Bioengineering 2026, 13(6), 599; https://doi.org/10.3390/bioengineering13060599 - 22 May 2026
Viewed by 543
Abstract
Optically pumped magnetometer-based magnetoencephalography (OPM-MEG), with its flexible sensor configuration and wide range of application scenarios, has become a powerful complement to conventional superconducting quantum interference device magnetoencephalography (SQUID-MEG). However, this higher flexibility also means that OPM-MEG sensor arrays are more susceptible to [...] Read more.
Optically pumped magnetometer-based magnetoencephalography (OPM-MEG), with its flexible sensor configuration and wide range of application scenarios, has become a powerful complement to conventional superconducting quantum interference device magnetoencephalography (SQUID-MEG). However, this higher flexibility also means that OPM-MEG sensor arrays are more susceptible to interference from complex and variable background magnetic noise. Previous research has shown that deploying reference sensors around the scalp array for noise cancellation is an effective strategy. Nonetheless, the selection of its key parameter, the spatial distance between the reference and scalp sensors, commonly termed the synthetic baseline, predominantly relies on empirical rules and lacks systematic theoretical optimization. To address this issue, this study thoroughly investigates the fundamental impact of the synthetic baseline on the system’s noise suppression performance. Simulation results demonstrate that the optimal baseline length is not a fixed value but varies systematically with environmental noise characteristics and the specific requirements of the source localization task. Building on this analysis, a Baseline Adaptive Reference Optimization (BARO) method is proposed. As an environment-driven strategy, the BARO method automatically determines the optimal baseline configuration by maximizing the output signal-to-noise ratio (SNR). Compared to traditional fixed-baseline configurations, the proposed BARO method significantly enhances the output SNR and effectively reduces the localization error of equivalent current dipoles within the brain across various simulated complex noise scenarios. This work provides a physically interpretable criterion for baseline optimization and offers theoretical support for environment-adaptive configuration of OPM-MEG sensor arrays. Full article
(This article belongs to the Section Biosignal Processing)
Show Figures

Figure 1

16 pages, 3767 KB  
Article
A Single-Cell Optically Pumped Intrinsic Gradiometer
by Nicholaus Zilinski, Ash M. Parameswaran, Bonnie L. Gray and Teresa Cheung
Sensors 2026, 26(5), 1678; https://doi.org/10.3390/s26051678 - 6 Mar 2026
Viewed by 974
Abstract
Optically pumped magnetometers (OPMs) provide a non-cryogenic alternative to superconducting quantum interference devices (SQUIDs) for detecting weak biomagnetic fields. We report the design, construction, and characterization of a single-cell intrinsic OPM gradiometer. The gradiometer employs a rubidium-87 vapor cell in an orthogonal pump [...] Read more.
Optically pumped magnetometers (OPMs) provide a non-cryogenic alternative to superconducting quantum interference devices (SQUIDs) for detecting weak biomagnetic fields. We report the design, construction, and characterization of a single-cell intrinsic OPM gradiometer. The gradiometer employs a rubidium-87 vapor cell in an orthogonal pump and probe beam configuration. The pump beam was split to illuminate two parallel sensing regions of the cell, separated by a baseline of 3 cm, with opposing circular polarization. A linearly polarized probe beam propagated through both regions and was captured by a balanced polarimeter whose output directly measured the spatial magnetic gradient. This prototype achieved a common-mode rejection ratio exceeding 50 dB and a sensitivity of 267 pT/cm/√Hz without passive magnetic shielding, using active ambient-field coils. As a proof of concept, we recorded preliminary cardiac-synchronous magnetic measurements using an optical pulse sensor for beat segmentation. After bandpass filtering and ensemble averaging, a cardiac-synchronous waveform was observed, consistent with cardiac timing. Unlike many multi-cell gradiometers that require complex calibration, modulation, and passive shielding, this single-cell design reduces cost and complexity. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

25 pages, 3577 KB  
Article
Optimizing OPM-MEG Sensor Layouts Using the Sequential Selection Algorithm with Simulated Sources and Individual Anatomy
by Urban Marhl, Rok Hren, Tilmann Sander and Vojko Jazbinšek
Sensors 2026, 26(4), 1292; https://doi.org/10.3390/s26041292 - 17 Feb 2026
Viewed by 905
Abstract
Magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) offers the flexibility to position sensors closer to the scalp, which improves the signal-to-noise ratio compared to conventional superconducting quantum interference device (SQUID) systems. However, the spatial resolution of OPM-MEG critically depends on sensor placement, [...] Read more.
Magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) offers the flexibility to position sensors closer to the scalp, which improves the signal-to-noise ratio compared to conventional superconducting quantum interference device (SQUID) systems. However, the spatial resolution of OPM-MEG critically depends on sensor placement, especially when the number of sensors is limited. In this study, we present a methodology for optimizing OPM-MEG sensor layouts using each subject’s anatomical information derived from individual magnetic resonance imaging (MRI). We generated realistic forward models from reconstructed head surfaces and simulated magnetic fields produced by equivalent current dipoles (ECDs). We compared multiple simulation strategies, including ECDs randomly distributed across the cortical surface and ECDs constrained to regions of interest. For each simulated magnetic field map (MFM) database, we applied the sequential selection algorithm (SSA) to identify sensor positions that maximized information capture. Unlike previous approaches relying on large measurement databases, this simulation-driven strategy eliminates the need for extensive pre-existing recordings. We benchmarked the performance of the personalized layouts using OPM-MEG datasets of auditory evoked fields (AEFs) derived from real whole-head SQUID-MEG measurements. Our results show that simulation-based SSA optimization improves the coverage of cortical regions of interest, reduces the number of sensors required for accurate source reconstruction, and yields sensor configurations that perform comparably to layouts optimized using measured data. To evaluate the quality of estimated MFMs, we applied metrics such as the correlation coefficient (CC), root-mean-square error, and relative error. Our results show that the first 15 to 20 optimally selected sensors (CC > 0.95) capture most of the information contained in full-head MFMs. Additionally, we performed source localization for the highest auditory response (M100) by fitting equivalent current dipoles and found that localization errors were < 5 mm. The results further indicate that SSA performance is insensitive to individualized head geometry, supporting the feasibility of using representative anatomical models and highlighting the potential of this approach for clinical OPM-MEG applications. Full article
(This article belongs to the Special Issue Feature Papers in Biomedical Sensors 2025)
Show Figures

Figure 1

18 pages, 4202 KB  
Article
Scanning Magnetic Microscopy Using a High-Sensitivity Room-Temperature Tunnel Magnetoresistance Sensor for Geological Applications
by Hirokuni Oda, Kosuke Fujiwara, Naoto Fukuyo, Hitoshi Kubota, Tomohiro Ichinose, Mikihiko Oogane, Seiji Kumagai, Hitoshi Matsuzaki, Taizo Uchida, Miki Kawabata and Jun Kawai
Sensors 2026, 26(3), 1075; https://doi.org/10.3390/s26031075 - 6 Feb 2026
Viewed by 1177
Abstract
This paper reports magnetic microscopy using high-sensitivity room-temperature tunnel magnetoresistance (TMR) devices for thin geological sections. The sensitivity region of the TMR sensor has dimensions of 178 µm (L) × 0.1 µm (W) × 100 µm (H), consisting of two TMR devices. Magnetic [...] Read more.
This paper reports magnetic microscopy using high-sensitivity room-temperature tunnel magnetoresistance (TMR) devices for thin geological sections. The sensitivity region of the TMR sensor has dimensions of 178 µm (L) × 0.1 µm (W) × 100 µm (H), consisting of two TMR devices. Magnetic images were obtained for a vertically magnetized Hawaii basalt thin section in two sensor configurations, with the sensor length aligned parallel to the X- (lift-off = 174 μm) and Y-axes (lift-off = 200 μm), without introducing anisotropic distortion in the magnetic images. Although the magnetic images obtained with a scanning SQUID microscope (SSM) were similar, slight discrepancies were observed in the high-spatial-resolution region. A magnetic point source (50 μm × 50 μm) with a perpendicular magnetization film was prepared for evaluation. The SSM measurements showed a clear magnetic dipole at an angle of approximately 1° from the vertical direction. The FWHMs for both the SSM and TMR sensors increased linearly with lift-off. However, the peak magnetic fields, magnetic moments, and dipole tilts of the TMR sensor were significantly larger than those of the SSM sensor. This discrepancy may be due to the vertical extent of the active region of the TMR sensor, as well as due to sensor noise and drift. Full article
(This article belongs to the Special Issue Smart Magnetic Sensors and Application)
Show Figures

Figure 1

10 pages, 1501 KB  
Communication
Magnetic Detection of Cancer Cells Using Tumor-Homing Peptide-Modified Magnetic Nanoparticles
by Shengli Zhou, Yuji Furutani, Kei Yamashita, Sakuya Kako, Kazunori Watanabe, Toshihiko Kiwa and Takashi Ohtsuki
Biosensors 2026, 16(1), 45; https://doi.org/10.3390/bios16010045 - 5 Jan 2026
Cited by 1 | Viewed by 1209
Abstract
Magnetic nanoparticles (MNPs) provide a platform for target detection because of their magnetic responsiveness to alternating magnetic fields (AMFs). We developed a detection method using MNPs modified with tumor-homing peptides (THPs), PL1 and PL3, which selectively bind to protein components enriched in malignant [...] Read more.
Magnetic nanoparticles (MNPs) provide a platform for target detection because of their magnetic responsiveness to alternating magnetic fields (AMFs). We developed a detection method using MNPs modified with tumor-homing peptides (THPs), PL1 and PL3, which selectively bind to protein components enriched in malignant tissues. THP-MNPs were synthesized using maleimide-PEG-NHS linkers and characterized using transmission electron microscopy. Human glioblastoma cancer U87MG and normal tissue-derived HEK293 cells were incubated with THP-MNPs, and the magnetic signals were measured using a high-temperature superconducting quantum interference device (SQUID) magnetometer under an AMF (1.06 kHz). Dark-field microscopy confirmed the preferential binding of THP-MNPs to U87MG cells. In the absence of cells, THP-MNPs exhibited AMF-dependent signal enhancement, which correlated with particle size reduction due to THP release. This increase was completely suppressed in the presence of U87MG cells, indicating a strong THP-mediated interaction. PL3-MNPs exhibited superior discrimination between malignant and non-malignant cells. These results demonstrate that SQUID-based magnetic measurements using THP-MNPs enable rapid and label-free cancer cell detection. Full article
(This article belongs to the Special Issue Biosensing Applications for Cell Monitoring—2nd Edition)
Show Figures

Figure 1

21 pages, 3214 KB  
Review
Superconductivity and Cryogenics in Medical Diagnostics and Treatment: An Overview of Selected Applications
by Oleksandr Boiko and Henryka Danuta Stryczewska
Appl. Sci. 2025, 15(23), 12579; https://doi.org/10.3390/app152312579 - 27 Nov 2025
Viewed by 3145
Abstract
This article presents a comprehensive overview of the current and emerging roles of cryogenics and superconductivity in medical diagnostics, imaging, and therapy. Beginning with the historical foundations of both fields and their technological maturation, this review emphasizes how cryogenic engineering and superconducting materials [...] Read more.
This article presents a comprehensive overview of the current and emerging roles of cryogenics and superconductivity in medical diagnostics, imaging, and therapy. Beginning with the historical foundations of both fields and their technological maturation, this review emphasizes how cryogenic engineering and superconducting materials have become indispensable to modern medical systems. Cryogenic technologies are highlighted in applications such as cryosurgery, cryotherapy, cryostimulation, and cryopreservation, all of which rely on controlled exposure to extremely low temperatures for therapeutic or biological preservation purposes. This article outlines the operating principles of cryomedical devices, the refrigerants and cooling methods used, and the technological barriers. This paper reviews the latest applications of superconductivity phenomena in medicine and identifies those that could be used in the future. These include cryogenic therapy, radiotherapy (cyclotrons, particle accelerators, synchrotron radiation generation, isotope production, and proton and ion beam delivery), magnetic resonance imaging (MRI), nuclear magnetic resonance spectroscopy (NMR), positron emission tomography (PET), and ultra-sensitive magnetic signal transducers based on SQUIDs for detecting ultra-low bio-signals emitted by human body organs. CT, MRI/NMR, and PET features are compared using the operation principle, specific applications, safety, contraindications for patients, examination time, and additional valued peculiarities. This article outlines the prospects for the development of superconducting and cryogenic materials and technologies in medical applications. Advances in diagnostic imaging are reviewed, with particular attention on the progression from conventional MRI scanners to ultra-high-field (UHF) systems exceeding 7–10.5 T, culminating in the 11.7 T Iseult whole-body MRI magnet. Another important application area described in this article includes biofunctionalized magnetic nanoparticles and superconducting quantum interference devices (SQUIDs), which enable the ultrasensitive detection of biomagnetic fields and targeted cancer diagnostics. Finally, this article identifies future directions of development in superconducting and cryogenic technologies for medicine. Full article
(This article belongs to the Section Electrical, Electronics and Communications Engineering)
Show Figures

Figure 1

12 pages, 1025 KB  
Article
Detecting Event-Related Spectral Perturbations in Right-Handed Sensorimotor Cortical Responses Using OPM-MEG
by Hao Lu, Yong Li, Min Xiang, Yuyu Ma, Yang Gao and Xiaolin Ning
Bioengineering 2025, 12(10), 1022; https://doi.org/10.3390/bioengineering12101022 - 25 Sep 2025
Viewed by 1391
Abstract
The optically pumped magnetometer, OPM-MEG, has the potential to replace the traditional low-temperature superconducting quantum interference device, SQUID-MEG. Event-related spectral perturbations (ERSPs) can be used to examine the temporal- and frequency-domain characteristics of a signal. In this paper, a finger-tapping movement paradigm based [...] Read more.
The optically pumped magnetometer, OPM-MEG, has the potential to replace the traditional low-temperature superconducting quantum interference device, SQUID-MEG. Event-related spectral perturbations (ERSPs) can be used to examine the temporal- and frequency-domain characteristics of a signal. In this paper, a finger-tapping movement paradigm based on auditory cues is adopted, and OPM-MEG is used to measure the functional signals of the brain. The event-related spectral perturbation values of the right and left hands of right-handed people were calculated and compared. The results showed that there was a significant difference in the event-related spectral perturbations between the right and left hands of right-handed people. In summary, OPM-MEG has the ability to measure the event-related spectral perturbations of the brain during finger movements and verify the asymmetry of motor skills. Full article
Show Figures

Figure 1

14 pages, 3968 KB  
Article
Investigating the Coherence Between Motor Cortex During Rhythmic Finger Tapping Using OPM-MEG
by Hao Lu, Yong Li, Yang Gao, Ying Liu and Xiaolin Ning
Photonics 2025, 12(8), 766; https://doi.org/10.3390/photonics12080766 - 29 Jul 2025
Cited by 2 | Viewed by 2233
Abstract
Optically pumped magnetometer OPM-MEG has the potential to replace the traditional low-temperature superconducting quantum interference device SQUID-MEG. Coherence analysis can be used to evaluate the functional connectivity and reflect the information transfer process between brain regions. In this paper, a finger tapping movement [...] Read more.
Optically pumped magnetometer OPM-MEG has the potential to replace the traditional low-temperature superconducting quantum interference device SQUID-MEG. Coherence analysis can be used to evaluate the functional connectivity and reflect the information transfer process between brain regions. In this paper, a finger tapping movement paradigm based on auditory cues was used to measure the functional signals of the brain using OPM-MEG, and the coherence between the primary motor cortex (M1) and the primary motor area (PM) was calculated and analyzed. The results demonstrated that the coherence of the three frequency bands of Alpha (8–13 Hz), Beta (13–30 Hz), and low Gamma (30–45 Hz) and the selected reference signal showed roughly the same position, the coherence strength and coherence range decreased from Alpha to low Gamma, and the coherence coefficient changed with time. It was inferred that the change in coherence indicated different neural patterns in the contralateral motor cortex, and these neural patterns also changed with time, thus reflecting the changes in the connection between different functional areas in the time-frequency domain. In summary, OPM-MEG has the ability to measure brain coherence during finger movements and can characterize connectivity between brain regions. Full article
Show Figures

Figure 1

32 pages, 5809 KB  
Review
Superconducting Quantum Magnetometers for Brain Investigations
by Carmela Bonavolontà, Antonio Vettoliere, Pierpaolo Sorrentino and Carmine Granata
Sensors 2025, 25(15), 4625; https://doi.org/10.3390/s25154625 - 25 Jul 2025
Cited by 8 | Viewed by 6749
Abstract
This review article aims to provide an overview of superconducting magnetic quantum sensors and their applications in the biomedical field, particularly in the neurological field. These quantum sensors are based on superconducting quantum interference devices (SQUIDs), the operating principles of which will be [...] Read more.
This review article aims to provide an overview of superconducting magnetic quantum sensors and their applications in the biomedical field, particularly in the neurological field. These quantum sensors are based on superconducting quantum interference devices (SQUIDs), the operating principles of which will be presented along with the most relevant characteristics. Emphasis will be placed on the magnetic flux and magnetic field noise, which are essential for applications, especially brain investigations requiring ultra-high magnetic field sensitivity. The main configurations of SQUID magnetometers used for highly sensitive applications will be shown, stressing their design aspects. In particular, the configurations based on the superconducting flux transformer and the multiloop will be explained. We will discuss the most critical application of SQUID magnetometers, magnetoencephalography, which measures the weak magnetic signals produced by neuronal currents. Starting from the realization of a multichannel system for magnetoencephalography, we will present an accurate comparison with recent systems using optically pumped magnetometers. Finally, we will discuss the main clinical applications of magnetoencephalography. Full article
(This article belongs to the Special Issue Advances and Applications of Magnetic Sensors: 2nd Edition)
Show Figures

Figure 1

12 pages, 3782 KB  
Article
Structural, Magnetic and THz Emission Properties of Ultrathin Fe/L10-FePt/Pt Heterostructures
by Claudiu Locovei, Garik Torosyan, Evangelos Th. Papaioannou, Alina D. Crisan, Rene Beigang and Ovidiu Crisan
Nanomaterials 2025, 15(14), 1099; https://doi.org/10.3390/nano15141099 - 16 Jul 2025
Cited by 3 | Viewed by 1285
Abstract
Recent achievements in ultrafast spin physics have enabled the use of heterostructures composed of ferromagnetic (FM)/non-magnetic (NM) thin layers for terahertz (THz) generation. The mechanism of THz emission from FM/NM multilayers has been typically ascribed to the inverse spin Hall effect (ISHE). In [...] Read more.
Recent achievements in ultrafast spin physics have enabled the use of heterostructures composed of ferromagnetic (FM)/non-magnetic (NM) thin layers for terahertz (THz) generation. The mechanism of THz emission from FM/NM multilayers has been typically ascribed to the inverse spin Hall effect (ISHE). In this work, we probe the mechanism of the ISHE by inserting a second ferromagnetic layer in the form of an alloy between the FM/NM system. In particular, by utilizing the co-sputtering technique, we fabricate Fe/L10-FePt/Pt ultra-thin heterostructures. We successfully grow the tetragonal phase of FePt (L10-phase) as revealed by X-ray diffraction and reflection techniques. We show the strong magnetic coupling between Fe and L10-FePt using magneto-optical and Superconducting Quantum Interference Device (SQUID) magnetometry. Subsequently, by utilizing THz time domain spectroscopy technique, we record the THz emission and thus we the reveal the efficiency of spin-to-charge conversion in Fe/L10-FePt/Pt. We establish that Fe/L10-FePt/Pt configuration is significantly superior to the Fe/Pt bilayer structure, regarding THz emission amplitude. The unique trilayer structure opens new perspectives in terms of material choices for the future spintronic THz sources. Full article
(This article belongs to the Special Issue Ferroelectricity, Multiferroicity, and Magnetism in Nanomaterials)
Show Figures

Figure 1

21 pages, 1903 KB  
Article
Unlocking Superior MFH Performance Below Hergt’s Biological Safety Limit: SPION-Based Magnetic Nanoplatforms Deliver High Heating Efficiency at Low AMF
by Atul Sudame and Dipak Maity
Bioengineering 2025, 12(7), 715; https://doi.org/10.3390/bioengineering12070715 - 30 Jun 2025
Cited by 1 | Viewed by 1397
Abstract
Superparamagnetic iron oxide nanoparticles (SPIONs) have gained significant attention for Magnetic Fluid Hyperthermia (MFH)-based cancer therapy. However, achieving high heating efficiency under a biologically safe Alternating Magnetic Field (AMF) remains a challenge. This study investigates the synthesis and optimization of SPIONs encapsulated in [...] Read more.
Superparamagnetic iron oxide nanoparticles (SPIONs) have gained significant attention for Magnetic Fluid Hyperthermia (MFH)-based cancer therapy. However, achieving high heating efficiency under a biologically safe Alternating Magnetic Field (AMF) remains a challenge. This study investigates the synthesis and optimization of SPIONs encapsulated in TPGS-stabilized PLGA nanoparticles (TPS-NPs) using a modified single emulsion solvent evaporation (M-SESE) method. The aim was to achieve efficient magnetic heating under biologically safe AMF conditions while maintaining biocompatibility and colloidal stability, making these magnetic nanoplatforms suitable for MFH-based cancer treatment. TPS-NPs were characterized using various techniques, including Dynamic Light Scattering (DLS), Atomic Force Microscopy (AFM), Transmission Electron Microscopy (TEM), and Superconducting Quantum Interference Device (SQUID) magnetometry, to evaluate their hydrodynamic size (Dh), zeta potential (ζ), encapsulation efficiency, and superparamagnetic properties. Calorimetric MFH studies demonstrated superior heating efficiency, with Specific Absorption Rate (SAR) and Intrinsic Loss Power (ILP) values optimized at an AMF of 4.1 GAm−1s−1, remaining within Hergt’s biological safety limit (~5 GAm−1s−1). These findings suggest that SPION-encapsulated TPS-NPs exhibit enhanced heat induction, making them promising candidates for MFH-based cancer therapy. The study highlights their potential as multifunctional nanoplatforms for magnetic hyperthermia therapy, paving the way for clinical translation in oncology for advanced cancer treatment. Full article
Show Figures

Figure 1

15 pages, 15202 KB  
Article
Field Testing of a Controlled-Source Wide Frequency Range Magnetotelluric Detector Using SQUID and Inductive Magnetic Sensors
by Zucan Lin, Qisheng Zhang, Rongbo Zhang, Xiyuan Zhang, Hui Zhang, Xinchang Wang, Huiying Li, Yunheng Liu, Bojian Zhou, Jian Shao and Keyu Zhou
Sensors 2025, 25(13), 3896; https://doi.org/10.3390/s25133896 - 23 Jun 2025
Viewed by 3666
Abstract
To enhance the resolution of shallow geological structure detection, this study developed a Controlled-Source wide frequency range Magnetotelluric Detector (called CSUMT) with a frequency range spanning from 1 Hz to 1 MHz, and conducted systematic field experiments in Fengxian County, Shaanxi Province. The [...] Read more.
To enhance the resolution of shallow geological structure detection, this study developed a Controlled-Source wide frequency range Magnetotelluric Detector (called CSUMT) with a frequency range spanning from 1 Hz to 1 MHz, and conducted systematic field experiments in Fengxian County, Shaanxi Province. The CSUMT system employs a high-precision 24-bit analog-to-digital converter and is compatible with both inductive magnetic sensors and superconducting quantum interference device (SQUID) magnetic sensors, featuring wide bandwidth and high dynamic range. Comparative experiments with the commercial V8 instrument demonstrated high consistency in electric field, magnetic field, and apparent resistivity measurements, confirming the CSUMT system’s reliability in field applications. In addition, this study compared the performance of inductive and SQUID magnetic sensors in actual surveys, revealing that SQUID sensors exhibit lower noise and more stable data output, making them suitable for signal detection across a broader frequency range. The results validate the practicality of the CSUMT system in complex geological environments and provide experimental support for the appropriate selection of magnetic sensors. Full article
(This article belongs to the Section Environmental Sensing)
Show Figures

Figure 1

24 pages, 3951 KB  
Article
Optimization of OPM-MEG Layouts with a Limited Number of Sensors
by Urban Marhl, Rok Hren, Tilmann Sander and Vojko Jazbinšek
Sensors 2025, 25(9), 2706; https://doi.org/10.3390/s25092706 - 24 Apr 2025
Cited by 5 | Viewed by 3621
Abstract
Magnetoencephalography (MEG) is a non-invasive neuroimaging technique that measures weak magnetic fields generated by neural electrical activity in the brain. Traditional MEG systems use superconducting quantum interference device (SQUID) sensors, which require cryogenic cooling and employ a dense array of sensors to capture [...] Read more.
Magnetoencephalography (MEG) is a non-invasive neuroimaging technique that measures weak magnetic fields generated by neural electrical activity in the brain. Traditional MEG systems use superconducting quantum interference device (SQUID) sensors, which require cryogenic cooling and employ a dense array of sensors to capture magnetic field maps (MFMs) around the head. Recent advancements have introduced optically pumped magnetometers (OPMs) as a promising alternative. Unlike SQUIDs, OPMs do not require cooling and can be placed closer to regions of interest (ROIs). This study aims to optimize the layout of OPM-MEG sensors, maximizing information capture with a limited number of sensors. We applied a sequential selection algorithm (SSA), originally developed for body surface potential mapping in electrocardiography, which requires a large database of full-head MFMs. While modern OPM-MEG systems offer full-head coverage, expected future clinical use will benefit from simplified procedures, where handling a lower number of sensors is easier and more efficient. To explore this, we converted full-head SQUID-MEG measurements of auditory-evoked fields (AEFs) into OPM-MEG layouts with 80 sensor sites. System conversion was done by calculating a current distribution on the brain surface using minimum norm estimation (MNE). We evaluated the SSA’s performance under different protocols, for example, using measurements of single or combined OPM components. We assessed the quality of estimated MFMs using metrics, such as the correlation coefficient (CC), root-mean-square error, and relative error. Additionally, we performed source localization for the highest auditory response (M100) by fitting equivalent current dipoles. Our results show that the first 15 to 20 optimally selected sensors (CC > 0.95, localization error < 1 mm) capture most of the information contained in full-head MFMs. Our main finding is that for event-related fields, such as AEFs, which primarily originate from focal sources, a significantly smaller number of sensors than currently used in conventional MEG systems is sufficient to extract relevant information. Full article
(This article belongs to the Collection Medical Applications of Sensor Systems and Devices)
Show Figures

Figure 1

17 pages, 5664 KB  
Article
Phantom-Based Approach for Comparing Conventional and Optically Pumped Magnetometer Magnetoencephalography Systems
by Daisuke Oyama and Hadi Zaatiti
Sensors 2025, 25(7), 2063; https://doi.org/10.3390/s25072063 - 26 Mar 2025
Cited by 6 | Viewed by 4135
Abstract
Magnetoencephalography (MEG) is a vital tool for understanding neural dynamics, offering a noninvasive technique for measuring subtle magnetic field variations around the scalp generated by synchronized neuronal activity. Two prominent sensor technologies exist: the well-established superconducting quantum interference device (SQUID) and the more [...] Read more.
Magnetoencephalography (MEG) is a vital tool for understanding neural dynamics, offering a noninvasive technique for measuring subtle magnetic field variations around the scalp generated by synchronized neuronal activity. Two prominent sensor technologies exist: the well-established superconducting quantum interference device (SQUID) and the more recent optically pumped magnetometer (OPM). Although many studies have compared these technologies using human-subject data in neuroscience and clinical studies, a direct hardware-level comparison using dry phantoms remains unexplored. This study presents a framework for comparing SQUID- with OPM-MEG systems in a controlled environment using a dry phantom that emulates neuronal activity, allowing strict control over physiological artifacts. Data were obtained from SQUID and OPM systems within the same shielded room, ensuring consistent environmental noise control and shielding conditions. Positioning the OPM sensors closer to the signal source resulted in a signal amplitude approximately 3–4 times larger than that detected by the SQUID-MEG system. However, the source localization error of the OPM-MEG system was approximately three times larger than that obtained by the SQUID-MEG system. The cause of the large source localization error was discussed in terms of sensor-to-source distance, sensor count, signal–noise ratio, and the spatial coverage provided by the sensor array of the source signal. Full article
(This article belongs to the Special Issue Advances in Magnetic Sensors and Their Applications)
Show Figures

Figure 1

Back to TopTop